TY - JOUR A1 - Bragard, Michael A1 - Soltau, N. A1 - Thomas, S. A1 - De Doncker, R. W. T1 - The balance of renewable sources and user demands in grids : power electronics for modular battery energy storage systems JF - IEEE transactions on power electronics N2 - The continuously growing amount of renewable sources starts compromising the stability of electrical grids. Contradictory to fossil fuel power plants, energy production of wind and photovoltaic (PV) energy is fluctuating. Although predictions have significantly improved, an outage of multi-MW offshore wind farms poses a challenging problem. One solution could be the integration of storage systems in the grid. After a short overview, this paper focuses on two exemplary battery storage systems, including the required power electronics. The grid integration, as well as the optimal usage of volatile energy reserves, is presented for a 5- kW PV system for home application, as well as for a 100- MW medium-voltage system, intended for wind farm usage. The efficiency and cost of topologies are investigated as a key parameter for large-scale integration of renewable power at medium- and low-voltage. Y1 - 2010 U6 - http://dx.doi.org/10.1109/TPEL.2010.2085455 SN - 0885-8993 VL - 25 IS - 12 SP - 3049 EP - 3056 PB - IEEE CY - New York ER - TY - JOUR A1 - Ferrein, Alexander A1 - Niemüller, Tim A1 - Steinbauer, Gerald T1 - Team Zadeat 2010 : application for participation Y1 - 2010 ER - TY - JOUR A1 - Schlamann, Marc A1 - Yoon, Min-Suk A1 - Maderwald, Stefan A1 - Pietrzyk, Thomas A1 - Bitz, Andreas A1 - Gerwig, Marcus A1 - Forsting, Michael A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Kastrup, Oliver T1 - Short term effects of magnetic resonance imaging on excitability of the motor cortex at 1.5T and 7T JF - Academic Radiology N2 - Rationale and Objectives The increasing spread of high-field and ultra-high-field magnetic resonance imaging (MRI) scanners has encouraged new discussion of the safety aspects of MRI. Few studies have been published on possible cognitive effects of MRI examinations. The aim of this study was to examine whether changes are measurable after MRI examinations at 1.5 and 7 T by means of transcranial magnetic stimulation (TMS). Materials and Methods TMS was performed in 12 healthy, right-handed male volunteers. First the individual motor threshold was specified, and then the cortical silent period (SP) was measured. Subsequently, the volunteers were exposed to the 1.5-T MRI scanner for 63 minutes using standard sequences. The MRI examination was immediately followed by another TMS session. Fifteen minutes later, TMS was repeated. Four weeks later, the complete setting was repeated using a 7-T scanner. Control conditions included lying in the 1.5-T scanner for 63 minutes without scanning and lying in a separate room for 63 minutes. TMS was performed in the same way in each case. For statistical analysis, Wilcoxon's rank test was performed. Results Immediately after MRI exposure, the SP was highly significantly prolonged in all 12 subjects at 1.5 and 7 T. The motor threshold was significantly increased. Fifteen minutes after the examination, the measured value tended toward normal again. Control conditions revealed no significant differences. Conclusion MRI examinations lead to a transient and highly significant alteration in cortical excitability. This effect does not seem to depend on the strength of the static magnetic field. Y1 - 2010 U6 - http://dx.doi.org/10.1016/j.acra.2009.10.004 SN - 1076-6332 VL - 17 IS - 3 SP - 277 EP - 281 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Czarnecki, Christian A1 - Winkelmann, Axel A1 - Spiliopoulou, Myra T1 - Services in electronic telecommunication markets: a framework for planning the virtualization of processes JF - Electronic Markets N2 - The potential of electronic markets in enabling innovative product bundles through flexible and sustainable partnerships is not yet fully exploited in the telecommunication industry. One reason is that bundling requires seamless de-assembling and re-assembling of business processes, whilst processes in telecommunication companies are often product-dependent and hard to virtualize. We propose a framework for the planning of the virtualization of processes, intended to assist the decision maker in prioritizing the processes to be virtualized: (a) we transfer the virtualization pre-requisites stated by the Process Virtualization Theory in the context of customer-oriented processes in the telecommunication industry and assess their importance in this context, (b) we derive IT-oriented requirements for the removal of virtualization barriers and highlight their demand on changes at different levels of the organization. We present a first evaluation of our approach in a case study and report on lessons learned and further steps to be performed. KW - Telecommunication KW - Services KW - Process virtualization KW - Product bundling KW - Transformation Y1 - 2010 U6 - http://dx.doi.org/10.1007/s12525-010-0045-8 SN - 1422-8890 VL - 20 IS - 3-4 SP - 197 EP - 207 PB - Springer CY - Berlin ER - TY - JOUR A1 - Ferrein, Alexander T1 - Robot controllers for highly dynamic environments with real-time constraints JF - Künstliche Intelligenz : KI. 24 (2010), H. 2 Y1 - 2010 SN - 1610-1987 SP - 175 EP - 178 ER - TY - JOUR A1 - Orzada, Stephan A1 - Maderwald, Stefan A1 - Poser, Benedikt Andreas A1 - Bitz, Andreas A1 - Quick, Harald H. A1 - Ladd, Mark E. T1 - RF excitation using time interleaved acquisition of modes (TIAMO) to address B1 inhomogeneity in high-field MRI JF - Magnetic Resonance in Medicine N2 - As the field strength and, therefore, the operational frequency in MRI is increased, the wavelength approaches the size of the human head/body, resulting in wave effects, which cause signal decreases and dropouts. Several multichannel approaches have been proposed to try to tackle these problems, including RF shimming, where each element in an array is driven by its own amplifier and modulated with a certain (constant) amplitude and phase relative to the other elements, and Transmit SENSE, where spatially tailored RF pulses are used. In this article, a relatively inexpensive and easy to use imaging scheme for 7 Tesla imaging is proposed to mitigate signal voids due to B1 field inhomogeneity. Two time-interleaved images are acquired using a different excitation mode for each. By forming virtual receive elements, both images are reconstructed together using GRAPPA to achieve a more homogeneous image, with only small SNR and SAR penalty in head and body imaging at 7 Tesla. Y1 - 2010 U6 - http://dx.doi.org/10.1002/mrm.22527 SN - 1522-2594 VL - 64 IS - 2 SP - 327 EP - 333 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Schiffer, Stefan A1 - Ferrein, Alexander A1 - Lakemeyer, Gerhard T1 - Proceedings of the Fourth International Conference on Intelligent Robotics and Applications (ICIRA 2011) JF - Proceedings of the Fourth International Conference on Intelligent Robotics and Applications (ICIRA 2011) Y1 - 2010 SP - 1 EP - 10 ER - TY - JOUR A1 - Ferrein, Alexander A1 - Steinbauer, Gerald T1 - On the Way to High-Level Programming for Resource-Limited Embedded Systems with Golog JF - Simulation, Modeling, and Programming for Autonomous Robots Y1 - 2010 N1 - Lecture Notes in Computer Science ; 6472 ; Second International Conference, SIMPAR 2010, Darmstadt, Germany, November 15-18, 2010. Proceedings SP - 229 EP - 240 ER - TY - JOUR A1 - Hillgärtner, Michael T1 - Normative Regulations JF - ECPE Cluster Seminar EMC in Hybrid and Electric Vehicles : 18 May 2010, Fraunhofer Institute Erlangen Y1 - 2010 N1 - Seminar EMC in Hybrid and Electric Vehicles <2010, Erlangen> PB - European Center for Power Electronics CY - Nürnberg ER - TY - JOUR A1 - Schmitt, Robert A1 - Scholl, Ingrid A1 - Cai, Yu A1 - Xia, Ji A1 - Dziwoki, Paul A1 - Harding, Martin A1 - Pavim, Alberto T1 - Machine Vision System for Inline Inspection in Carbide Insert Production JF - Bildverarbeitung für die Medizin 2010 : Algorithmen, Systeme, Anwendungen ; Proceedings des Workshops vom 14. bis 16. März in Aachen / Thomas M. Deserno ... (Hrsg.) Y1 - 2010 SN - 978-3-642-11967-5 N1 - Proceedings of the 36th International MATADOR Conference ; Workshop Bildverarbeitung für die Medizin <2010, Aachen> SP - 339 EP - 342 PB - Springer CY - Berlin ER -