TY - JOUR A1 - Knüppel, Mark T1 - Pro-Forma-Angaben JF - Handbuch der Bilanzierung : das gesamte Wissen zur Rechnungslegung nach HGB, EStG und IFRS / Federmann, Rudolf ; Gnam, Arnulf ; Ammedick, Oliver Y1 - 2002 N1 - Aktuelle Informationen in Erg.-Lfg. 122 [nicht mehr vorhanden] SP - 1950 EP - 1952 PB - Haufe CY - Freiburg ER - TY - JOUR A1 - Knüppel, Mark ED - Federmann, Rudolf ED - Kußmaul, Heinz ED - Müller, Stefan T1 - Außerbilanzielle Korrekturen JF - Handbuch der Bilanzierung online Y1 - 2012 SN - 0172-0392 SP - Artikel HI 1380074 PB - Haufe CY - Freiburg ER - TY - JOUR A1 - Knox, Ronald A1 - Bruggemann, Andrea A1 - Gossmann, Matthias A1 - Thomas, Ulrich A1 - Horváth, András A1 - Dragicevic, Elena A1 - Stoelzle-Feix, Sonja A1 - Fertig, Niels A1 - Jung, Alexander A1 - Raman, Aravind Hariharan A1 - Staat, Manfred A1 - Linder, Peter T1 - Combining physiological relevance and throughput for in vitro cardiac contractility measurement JF - Biophysical Journal N2 - Despite increasing acceptance of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) in safety pharmacology, controversy remains about the physiological relevance of existing in vitro models for their mechanical testing. We hypothesize that existing signs of immaturity of the cell models result from an improper mechanical environment. We cultured hiPSC-CMs in a 96-well format on hyperelastic silicone membranes imitating their native mechanical environment, resulting in physiological responses to compound stimuli.We validated cell responses on the FLEXcyte 96, with a set of reference compounds covering a broad range of cellular targets, including ion channel modulators, adrenergic receptor modulators and kinase inhibitors. Acute (10 - 30 min) and chronic (up to 7 days) effects were investigated. Furthermore, the measurements were complemented with electromechanical models based on electrophysiological recordings of the used cell types.hiPSC-CMs were cultured on freely-swinging, ultra-thin and hyperelastic silicone membranes. The weight of the cell culture medium deflects the membranes downwards. Rhythmic contraction of the hiPSC-CMs resulted in dynamic deflection changes which were quantified by capacitive distance sensing. The cells were cultured for 7 days prior to compound addition. Acute measurements were conducted 10-30 minutes after compound addition in standard culture medium. For chronic treatment, compound-containing medium was replaced daily for up to 7 days. Electrophysiological properties of the employed cell types were recorded by automated patch-clamp (Patchliner) and the results were integrated into the electromechanical model of the system.Calcium channel agonist S Bay K8644 and beta-adrenergic stimulator isoproterenol induced significant positive inotropic responses without additional external stimulation. Kinase inhibitors displayed cardiotoxic effects on a functional level at low concentrations. The system-integrated analysis detected alterations in beating shape as well as frequency and arrhythmic events and we provide a quantitative measure of these. Y1 - 2020 U6 - https://doi.org/10.1016/j.bpj.2019.11.3104 SN - 0006-3495 N1 - Raman, Arayind Hariharan im Artikel unter dem Namen: Raman, Alexander H. VL - 118 IS - Issue 3, Supplement 1 SP - 570a PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Knobe, M. A1 - Giesen, M. A1 - Plate, S. A1 - Gradl-Dietsch, G. A1 - Buecking, B. A1 - Eschbach, D. A1 - Laack, Walter van A1 - Pape, H.-C. T1 - The Aachen mobility and balance index to measure physiological falls risk: a comparison with the Tinetti POMA scale JF - European Journal Of Trauma And Emergency Surgery N2 - Purpose The most commonly used mobility assessments for screening risk of falls among older adults are rating scales such as the Tinetti performance oriented mobility assessment (POMA). However, its correlation with falls is not always predictable and disadvantages of the scale include difficulty to assess many of the items on a 3-point scale and poor specificity. The purpose of this study was to describe the ability of the new Aachen Mobility and Balance Index (AMBI) to discriminate between subjects with a fall history and subjects without such events in comparison to the Tinetti POMA Scale. Methods For this prospective cohort study, 24 participants in the study group and 10 in the control group were selected from a population of patients in our hospital who had met the stringent inclusion criteria. Both groups completed the Tinetti POMA Scale (gait and balance component) and the AMBI (tandem stance, tandem walk, ten-meter-walk-test, sit-to-stand with five repetitions, 360° turns, timed-up-and-go-test and measurement of the dominant hand grip strength). A history of falls and hospitalization in the past year were evaluated retrospectively. The relationships among the mobility tests were examined with Bland–Altmananalysis. Receiver-operated characteristics curves, sensitivity and specificity were calculated. Results The study showed a strong negative correlation between the AMBI (17 points max., highest fall risk) and Tinetti POMA Scale (28 points max., lowest fall risk; r = −0.78, p < 0.001) with an excellent discrimination between community-dwelling older people and a younger control group. However, there were no differences in any of the mobility and balance measurements between participants with and without a fall history with equal characteristics in test comparison (AMBI vs. Tinetti POMA Scale: AUC 0.570 vs. 0.598; p = 0.762). The Tinetti POMA Scale (cut-off <20 points) showed a sensitivity of 0.45 and a specificity of 0.69, the AMBI a sensitivity of 0.64 and a specificity of 0.46 (cut-off >5 points). Conclusion The AMBI comprises mobility and balance tasks with increasing difficulty as well as a measurement of the dominant hand-grip strength. Its ability to identify fallers was comparable to the Tinetti POMA Scale. However, both measurement sets showed shortcomings in discrimination between fallers and non-fallers based on a self-reported retrospective falls-status. KW - Tinetti test KW - Mobility KW - Mobility tests KW - Ground-level falls KW - Elderly KW - Fall prevention KW - Co-managed care KW - Balance Y1 - 2016 U6 - https://doi.org/10.1007/s00068-016-0693-2 SN - 1863-9941 VL - 42 IS - 5 SP - 537 EP - 545 PB - Springer CY - Berlin ER - TY - JOUR A1 - Knobbe, D.-T. A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Mourzina, Y. T1 - Charakterisierung von kapazitiven EMISSensoren mittels Impedanzspektroskopie, Kapazitäts-Spannungs- und Konstant-Kapazitäts-Messung JF - Sensoren und Messsysteme 2004 : Tagung Ludwigsburg, 15. und 16. März 2004 / VDI-VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2004 SN - 3-18-091829-2 N1 - Auch erschienen als: VDI-Berichte ; 1829 SP - 851 EP - 854 PB - VDI CY - Düsseldorf ER - TY - JOUR A1 - Knepper, Ludger T1 - Der moderne Luftfrachtverkehr - leistungsfaehig durch seine bodengebundenen Umschlagssysteme Y1 - 1985 N1 - Konferenzeinzelbericht : Transmatik 85. Kongress Neue Technologien im Materialfluss und in der Foerdertechnik, Univ. Karlsruhe, 10.-12.5.1985 SP - 60 EP - 69 ER - TY - JOUR A1 - Knepper, Ludger T1 - Hochregallager fuer Luftfracht - 365 Tage pro Jahr in Betrieb JF - Foerdern und Heben. 35 (1985), H. 5 Y1 - 1985 SN - 0341-2636 SP - 363 EP - 366 ER - TY - JOUR A1 - Knepper, Ludger T1 - Integrierte Hochregallager als materialflusstechnische Knotenpunkte moderner Produktions- und Umschlaganlagen Y1 - 1984 N1 - Konferenz-Einzelbericht : Materialfluss - Logistik und Technik. Seminar f. Materialfluss, Univ. Karlsruhe, 1984 SP - 93 EP - 100 ER - TY - JOUR A1 - Knepper, Ludger T1 - Verstaerkte materialflusstechnische Integration von Hochregallagern in Produktions- und Umschlaganlagen Y1 - 1983 N1 - Konferenz-Einzelbericht : 4. Int. Logistik Kongress. Deutsche Ges. f. Logistik (DGfL), Dortmund, 7.-9.12.1983. Kongresshandbuch 1 SP - 219 EP - 224 ER - TY - JOUR A1 - Knepper, Ludger T1 - Im neuen Lufthansa-Frachtterminal: vom Hochregallager direkt ins Flugzeug JF - Foerdermittel Journal. Kennzifferzeitschrift fuer Materialfluss, Lager und Transport. 13 (1981), H. 7/8 Y1 - 1981 SN - 0013-5674 SP - 22 EP - 24 ER -