TY - JOUR A1 - Klinge, Uwe A1 - Wilke, Ralf A1 - Mühl, Thomas T1 - Auswahl der Herniennetze nach der “effektiven Porosität” - warum das Gewicht weniger wichtig ist JF - Chirurgische Allgemeine : CHAZ ; Zeitung für Klinik und Praxis Y1 - 2012 SN - 1615-5378 VL - 13 IS - 12 SP - 297 EP - 301 PB - Kaden CY - Mannheim ER - TY - JOUR A1 - Bohrn, U. A1 - Stütz, E. A1 - Fuchs, K. A1 - Fleischer, M. A1 - Schöning, Michael Josef A1 - Wagner, P. T1 - Monitoring of irritant gas using a whole-cell-based sensor system JF - Sensors and Actuators B: Chemical N2 - Cell-based sensors for the detection of gases have long been underrepresented, due to the cellular requirement of being cultured in a liquid environment. In this work we established a cell-based gas biosensor for the detection of toxic substances in air, by adapting a commercial sensor chip (Bionas®), previously used for the measurement of pollutants in liquids. Cells of the respiratory tract (A549, RPMI 2650, V79), which survive at a gas phase in a natural context, are used as biological receptors. The physiological cell parameters acidification, respiration and morphology are continuously monitored in parallel. Ammonia was used as a highly water-soluble model gas to test the feasibility of the sensor system. Infrared measurements confirmed the sufficiency of the medium draining method. This sensor system provides a basis for many sensor applications such as environmental monitoring, building technology and public security. Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2012.05.088 SN - 0925-4005 VL - 175 SP - 208 EP - 217 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schneider, Bettina A1 - Schneider, Wilhelm T1 - Due Diligence – Grundlagen und Checkliste für KMU JF - Betriebswirtschaft im Blickpunkt N2 - Im Folgenden sollen Anlass und Inhalt einer Due Diligence erläutert werden. Im Rahmen einer Checkliste werden Beratern und Unternehmen Hinweise zu möglichen Prüfungsgebieten sowie zu vorzuhaltenden oder zu prüfenden Unterlagen gegeben. Entstanden ist die Checkliste aus der langjährigen praktischen Tätigkeit der Autoren bei einer großen Wirtschaftsprüfungsgesellschaft bzw. einer deutschen Großbank. Y1 - 2012 SN - 2191-1118 SP - 148 EP - 149 PB - IWW Institut für Wissen in der Wirtschaft CY - Nordkirchen ER - TY - JOUR A1 - Blecken, Udo A1 - Holthaus-Sellheier, Ursula T1 - Quantitative Prognoseverfahren für Mietpreise von Bueroimmobilien am Beispiel Düsseldorf JF - GuG : Grundstücksmarkt und Grundstückswert Y1 - 2012 SN - 0938-0175 VL - 23 IS - 1 SP - 12 EP - 21 PB - Werner CY - Köln ER - TY - JOUR A1 - Kurulgan Demirci, Eylem A1 - Demirci, Taylan A1 - Linder, Peter A1 - Trzewik, Jürgen A1 - Gierkowski, Jessica Ricarda A1 - Gossmann, Matthias A1 - Kayser, Peter A1 - Porst, Dariusz A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - rhAPC reduces the endothelial cell permeability via a decrease of contractile tensions induced by endothelial cells JF - Journal of Bioscience and Bioengineering N2 - All cells generate contractile tension. This strain is crucial for mechanically controlling the cell shape, function and survival. In this study, the CellDrum technology quantifying cell's (the cellular) mechanical tension on a pico-scale was used to investigate the effect of lipopolysaccharide (LPS) on human aortic endothelial cell (HAoEC) tension. The LPS effect during gram-negative sepsis on endothelial cells is cell contraction causing endothelium permeability increase. The aim was to finding out whether recombinant activated protein C (rhAPC) would reverse the endothelial cell response in an in-vitro sepsis model. In this study, the established in-vitro sepsis model was confirmed by interleukin 6 (IL-6) levels at the proteomic and genomic levels by ELISA, real time-PCR and reactive oxygen species (ROS) activation by florescence staining. The thrombin cellular contraction effect on endothelial cells was used as a positive control when the CellDrum technology was applied. Additionally, the Ras homolog gene family, member A (RhoA) mRNA expression level was checked by real time-PCR to support contractile tension results. According to contractile tension results, the mechanical predominance of actin stress fibers was a reason of the increased endothelial contractile tension leading to enhanced endothelium contractility and thus permeability enhancement. The originality of this data supports firstly the basic measurement principles of the CellDrum technology and secondly that rhAPC has a beneficial effect on sepsis influenced cellular tension. The technology presented here is promising for future high-throughput cellular tension analysis that will help identify pathological contractile tension responses of cells and prove further cell in-vitro models. KW - Cell permeability KW - Cellular force KW - Endothelial cells KW - Recombinant activated protein C KW - Lipopolysaccharide KW - Contractile tension KW - CellDrum Y1 - 2012 U6 - https://doi.org/10.1016/j.jbiosc.2012.03.019 SN - 1347-4421 VL - 113 IS - 2 SP - 212 EP - 219 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hüning, Felix A1 - Jaekel, C. A1 - Francois, I. A1 - Kyas, G. T1 - Microwave surface impedance measurements on high-Tc superconductors / Jaekel, C. ; Francois, I. ; Kyas, G. ; Hüning, F. ; Roskos, H. G. ; Borghs, G. ; Kurz, H. JF - Czechoslovak Journal of Physics. 46 (1996), H. Suppl. 2 Y1 - 1996 SN - 1572-9486 IS - 46 SP - 1117 EP - 1118 PB - Springer Science+Business Media CY - Dordrecht ER - TY - JOUR A1 - Hirschberg, Rainer T1 - Decentral pumps in heating systems - a new hydraulic approac JF - 1st International Rotating Equipment Conference - Pumps and Compressors, 9th Pump Users International Forum, 9. Internationales Pumpenanwenderforum, Final Report, Düsseldorf, DE, 28.-29. Oct, 2008 Y1 - 2008 SP - 1 EP - 10 PB - - ER - TY - JOUR A1 - Hirschberg, Rainer T1 - Wirtschaftlichkeit gebäudetechnischer Anlagen VDI 2067 - Berechnung des instationären thermischen Verhaltens von Räumen und Gebäuden nach VDI 6007 JF - Umsetzung der EU-Richtlinie (EPBD), Gesamtenergieeffizienz von Gebäuden - wie gehen wir damit um?, VDI-Gesellschaft Technische Gebäudeausrüstung (VDI-TGA), Dortmund, DE, 30.-31. Jan, 2007 Y1 - 2007 SN - 978-3-18-091952-2 N1 - VDI-Berichte 1952 PB - VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Engels, Elmar A1 - Krauskopf, S. T1 - Innovation in Motion-Logic programming - a versatile interface JF - Proceedings to the 12th International Workshop on Research and Education in Mechatronics, REM 2011, Kocaeli, Turkey, 15.09.-16.09.2011 Y1 - 2011 SN - 978-975-8047-96-3 PB - - ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Kirsanov, Dmitry A1 - Legin, Andrey A1 - Osterrath, Thomas A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Schöning, Michael Josef T1 - Development of a thin-film sensor array for analytical monitoring of heavy metals in aqueous solutions JF - Physica Status Solidi (a) N2 - In industrial processes there is a variety of heavy metals (e.g., copper, zinc, cadmium, and lead) in use for wires, coatings, paints, alloys, batteries, etc. Since the application of these transition metals for industry is inevitable, it is a vital task to develop proper analytical techniques for their monitoring at low activity levels, especially because most of these elements are acutely toxic for biological organisms. The determination of ions in solution by means of a simple and inexpensive sensor array is, therefore, a promising task. In this work, a sensor array with heavy metal-sensitive chalcogenide glass membranes for the simultaneous detection of the four ions Ag⁺, Cu2⁺, Cd2⁺, and Pb2⁺ in solution is realized. The results of the physical characterization by means of microscopy, profilometry, Rutherford backscattering spectroscopy (RBS), and scanning electron microscopy (SEM) as well as the electrochemical characterization by means of potentiometric measurements are presented. Additionally, the possibility to expand the sensor array by polymeric sensor membranes is discussed. Y1 - 2012 SN - 1862-6319 U6 - https://doi.org/10.1002/pssa.201100733 VL - 209 IS - 5 SP - 885 EP - 891 PB - Wiley-VCH CY - Weinheim ER -