TY - JOUR A1 - Nehr, Sascha A1 - Baus, Lukas A1 - Çinar, Hasan A1 - Elsen, Ingo A1 - Frauenrath, Tobias T1 - Indoor environmental quality assessment in passively ventilated classrooms in Germany and estimation of ventilation energy losses JF - Journal of Building Engineering N2 - In this field study we present an approach for the comprehensive and room-specific assessment of parameters with the overall aim to realize energy-efficient provision of hygienically harmless and thermally comfortable indoor environmental quality in naturally ventilated non-residential buildings. The approach is based on (i) conformity assessment of room design parameters, (ii) empirical determination of theoretically expected occupant-specific supply air flow rates and corresponding air exchange rates, (iii) experimental determination of real occupant-specific supply air flow rates and corresponding air exchange rates, (iv) measurement of indoor environmental exposure conditions of T, RH, cCO2 , cPM2.5 and cTVOC, and (v) determination of real energy demands for the prevailing ventilation scheme. Underlying assessment criteria comprise the indoor environmental parameters of category II of EN 16798-1: Temperature T = 20 ◦C–24 ◦C, and relative humidity RH = 25 %–60 % as well as the guide values of the German Federal Environment Agency for cCO2 cPM2.5 and cTVOC of 1000 ppm, 15 μg m⁻³, and 1 mg m ⁻³, respectively. Investigation objects are six naturally ventilated classrooms of a German secondary school. Major factors influencing indoor environmental quality in these classrooms are the specific room volume per occupant and the window opening area. It is concluded that the rigorous implementation of ventilation recommendations laid down by the German Federal Environment Agency is ineffective with respect to anticipated indoor environmental parameters and inefficient with respect to ventilation energy losses on the order of about 10 kWh m⁻² a ⁻¹ to 30 kWh m⁻² a ⁻¹. KW - Indoor air quality KW - Indoor environmental quality KW - Energy-efficient ventilation KW - CO2 KW - PM2.5 Y1 - 2024 SN - 2352-7102 VL - 97 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Gong, Jing A1 - Raut, Amod A1 - Pelzer, Marcel A1 - Hüning, Felix T1 - Marking-based perpendicular parking slot detection algorithm using LiDAR sensors JF - Vehicles N2 - The emergence of automotive-grade LiDARs has given rise to new potential methods to develop novel advanced driver assistance systems (ADAS). However, accurate and reliable parking slot detection (PSD) remains a challenge, especially in the low-light conditions typical of indoor car parks. Existing camera-based approaches struggle with these conditions and require sensor fusion to determine parking slot occupancy. This paper proposes a parking slot detection (PSD) algorithm which utilizes the intensity of a LiDAR point cloud to detect the markings of perpendicular parking slots. LiDAR-based approaches offer robustness in low-light environments and can directly determine occupancy status using 3D information. The proposed PSD algorithm first segments the ground plane from the LiDAR point cloud and detects the main axis along the driving direction using a random sample consensus algorithm (RANSAC). The remaining ground point cloud is filtered by a dynamic Otsu’s threshold, and the markings of parking slots are detected in multiple windows along the driving direction separately. Hypotheses of parking slots are generated between the markings, which are cross-checked with a non-ground point cloud to determine the occupancy status. Test results showed that the proposed algorithm is robust in detecting perpendicular parking slots in well-marked car parks with high precision, low width error, and low variance. The proposed algorithm is designed in such a way that future adoption for parallel parking slots and combination with free-space-based detection approaches is possible. This solution addresses the limitations of camera-based systems and enhances PSD accuracy and reliability in challenging lighting conditions. KW - point cloud processing KW - RANSAC KW - line detection KW - automated parking KW - LiDAR KW - parking slot detection Y1 - 2024 U6 - https://doi.org/10.3390/vehicles6040083 SN - 2624-8921 N1 - Corresponding author: Felix Hüning VL - 6 IS - 4 SP - 1717 EP - 1729 PB - MDPI CY - Basel ER - TY - JOUR A1 - Windmüller, Anna A1 - Schaps, Kristian A1 - Zantis, Frederik A1 - Domgans, Anna A1 - Taklu, Bereket Woldegbreal A1 - Yang, Tingting A1 - Tsai, Chih-Long A1 - Schierholz, Roland A1 - Yu, Shicheng A1 - Kungl, Hans A1 - Tempel, Hermann A1 - Dunin-Borkowski, Rafal E. A1 - Hüning, Felix A1 - Hwang, Bing Joe A1 - Eichel, Rüdiger-A. T1 - Electrochemical activation of LiGaO2: implications for ga-doped garnet solid electrolytes in li-metal batteries JF - ACS Applied Materials & Interfaces N2 - Ga-doped Li7La3Zr2O12 garnet solid electrolytes exhibit the highest Li-ion conductivities among the oxide-type garnet-structured solid electrolytes, but instabilities toward Li metal hamper their practical application. The instabilities have been assigned to direct chemical reactions between LiGaO2 coexisting phases and Li metal by several groups previously. Yet, the understanding of the role of LiGaO2 in the electrochemical cell and its electrochemical properties is still lacking. Here, we are investigating the electrochemical properties of LiGaO2 through electrochemical tests in galvanostatic cells versus Li metal and complementary ex situ studies via confocal Raman microscopy, quantitative phase analysis based on powder X-ray diffraction, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, and electron energy loss spectroscopy. The results demonstrate considerable and surprising electrochemical activity, with high reversibility. A three-stage reaction mechanism is derived, including reversible electrochemical reactions that lead to the formation of highly electronically conducting products. The results have considerable implications for the use of Ga-doped Li7La3Zr2O12 electrolytes in all-solid-state Li-metal battery applications and raise the need for advanced materials engineering to realize Ga-doped Li7La3Zr2O12for practical use. KW - LiGaO2 KW - garnet solid electrolyte KW - ga-doping KW - Li7La3Zr2O12 KW - solid-state battery Y1 - 2024 U6 - https://doi.org/10.1021/acsami.4c03729 SN - 39181–3919 VL - 16 IS - 30 PB - ACS Publications CY - Washington, DC ER - TY - JOUR A1 - Droop, Philipp A1 - Chen, Shaohuang A1 - Radford, Melissa J. A1 - Paulßen, Elisabeth A1 - Gates, Byron D. A1 - Reilly, Raymond M. A1 - Radchenko, Valery A1 - Hoehr, Cornelia T1 - Synthesis of 197m/gHg labelled gold nanoparticles for targeted radionuclide therapy JF - Radiochimica Acta N2 - Meitner-Auger-electron emitters have a promising potential for targeted radionuclide therapy of cancer because of their short range and the high linear energy transfer of Meitner-Auger-electrons (MAE). One promising MAE candidate is 197m/gHg with its half-life of 23.8 h and 64.1 h, respectively, and high MAE yield. Gold nanoparticles (AuNPs) that are labelled with 197m/gHg could be a helpful tool for radiation treatment of glioblastoma multiforme when infused into the surgical cavity after resection to prevent recurrence. To produce such AuNPs, 197m/gHg was embedded into pristine AuNPs. Two different syntheses were tested starting from irradiated gold containing trace amounts of 197m/gHg. When sodium citrate was used as reducing agent, no 197m/gHg labelled AuNPs were formed, but with tannic acid, 197m/gHg labeled AuNPs were produced. The method was optimized by neutralizing the pH (pH = 7) of the Au/197m/gHg solution, which led to labelled AuNPs with a size of 12.3 ± 2.0 nm as measured by transmission electron microscopy. The labelled AuNPs had a concentration of 50 μg (gold)/mL with an activity of 151 ± 93 kBq/mL (197gHg, time corrected to the end of bombardment). KW - 197m/gHg KW - Gold nanoparticle (AuNP) KW - Meitner-Auger-electron (MAE) KW - Targeted radionuclide therapy (TRT) Y1 - 2023 U6 - https://doi.org/10.1515/ract-2023-0144 SN - 2193-3405 VL - 111 IS - 10 SP - 773 EP - 779 PB - De Gruyter CY - Berlin [u.a.] ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Orzada, Stephan A1 - Flöser, Martina A1 - Rietsch, Stefan H. G. A1 - Quick, Harald H. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - Performance analysis of integrated RF microstrip transmit antenna arrays with high channel count for body imaging at 7 T JF - NMR in Biomedicine N2 - The aim of the current study was to investigate the performance of integrated RF transmit arrays with high channel count consisting of meander microstrip antennas for body imaging at 7 T and to optimize the position and number of transmit ele- ments. RF simulations using multiring antenna arrays placed behind the bore liner were performed for realistic exposure conditions for body imaging. Simulations were performed for arrays with as few as eight elements and for arrays with high channel counts of up to 48 elements. The B1+ field was evaluated regarding the degrees of freedom for RF shimming in the abdomen. Worst-case specific absorption rate (SARwc ), SAR overestimation in the matrix compression, the number of virtual obser- vation points (VOPs) and SAR efficiency were evaluated. Constrained RF shimming was performed in differently oriented regions of interest in the body, and the devia- tion from a target B1+ field was evaluated. Results show that integrated multiring arrays are able to generate homogeneous B1+ field distributions for large FOVs, espe- cially for coronal/sagittal slices, and thus enable body imaging at 7 T with a clinical workflow; however, a low duty cycle or a high SAR is required to achieve homoge- neous B1+ distributions and to exploit the full potential. In conclusion, integrated arrays allow for high element counts that have high degrees of freedom for the pulse optimization but also produce high SARwc , which reduces the SAR accuracy in the VOP compression for low-SAR protocols, leading to a potential reduction in array performance. Smaller SAR overestimations can increase SAR accuracy, but lead to a high number of VOPs, which increases the computational cost for VOP evaluation and makes online SAR monitoring or pulse optimization challenging. Arrays with interleaved rings showed the best results in the study. KW - body imaging at UHF MRI KW - integrated transmit coil arrays KW - VOP compression Y1 - 2021 U6 - https://doi.org/10.1002/nbm.4515 SN - 0952-3480 (ISSN) SN - 1099-1492 (eISSN) VL - 34 IS - 7 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Niendorf, Thoralf A1 - Kob, Malte T1 - Acoustic method for synchronization of Magnetic Resonance Imaging (MRI) JF - Acta Acustica N2 - Magnetic Resonance Imaging (MRI) of moving organs requires synchronization with physiological motion or flow, which dictate the viable window for data acquisition. To meet this challenge, this study proposes an acoustic gating device (ACG) that employs acquisition and processing of acoustic signals for synchronization while providing MRI compatibility, immunity to interferences with electro-magnetic and acoustic fields and suitability for MRI at high magnetic field strengths. The applicability and robustness of the acoustic gating approach is examined in a pilot study, where it substitutes conventional ECG-gating for cardiovascular MR. The merits and limitations of the ACG approach are discussed. Implications for MR imaging in the presence of physiological motion are considered including synchronization with other structure- or motion borne sounds. Y1 - 2008 U6 - https://doi.org/10.3813/AAA.918017 SN - 1861-9959 VL - 94 IS - 1 SP - 148 EP - 155 PB - Hirzel CY - Stuttgart ER - TY - JOUR A1 - Heinrichs, Uwe A1 - Utting, Jane F. A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Krombach, Gabriele A. A1 - Hodenius, Michael A. J. A1 - Kozerke, Sebastian A1 - Niendorf, Thoralf T1 - Myocardial T2 mapping free of distortion using susceptibility-weighted fast spin-echo imaging: A feasibility study at 1.5 T and 3.0 T JF - Magnetic Resonance in Medicine N2 - This study demonstrates the feasibility of applying free-breathing, cardiac-gated, susceptibility-weighted fast spin-echo imaging together with black blood preparation and navigator-gated respiratory motion compensation for anatomically accurate T₂ mapping of the heart. First, T₂ maps are presented for oil phantoms without and with respiratory motion emulation (T₂ = (22.1 ± 1.7) ms at 1.5 T and T₂ = (22.65 ± 0.89) ms at 3.0 T). T₂ relaxometry of a ferrofluid revealed relaxivities of R2 = (477.9 ± 17) mM⁻¹s⁻¹ and R2 = (449.6 ± 13) mM⁻¹s⁻¹ for UFLARE and multiecho gradient-echo imaging at 1.5 T. For inferoseptal myocardial regions mean T₂ values of 29.9 ± 6.6 ms (1.5 T) and 22.3 ± 4.8 ms (3.0 T) were estimated. For posterior myocardial areas close to the vena cava T₂-values of 24.0 ± 6.4 ms (1.5 T) and 15.4 ± 1.8 ms (3.0 T) were observed. The merits and limitations of the proposed approach are discussed and its implications for cardiac and vascular T₂-mapping are considered. Y1 - 2009 U6 - https://doi.org/10.1002/mrm.22054 SN - 1522-2594 VL - 62 IS - 3 SP - 822 EP - 828 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Kob, Malte A1 - Frauenrath, Tobias T1 - A system for parallel measurement of glottis opening and larynx position JF - Biomedical Signal Processing and Control N2 - The simultaneous assessment of glottal dynamics and larynx position can be beneficial for the diagnosis of disordered voice or speech production and swallowing. Up to now, methods either concentrate on assessment of the glottis opening using optical, acoustical or electrical (electroglottography, EGG) methods, or on visualisation of the larynx position using ultrasound, computer tomography or magnetic resonance imaging techniques. The method presented here makes use of a time-multiplex measurement approach of space-resolved transfer impedances through the larynx. The fast sequence of measurements allows a quasi simultaneous assessment of both larynx position and EGG signal using up to 32 transmit–receive signal paths. The system assesses the dynamic opening status of the glottis as well as the vertical and back/forward motion of the larynx. Two electrode-arrays are used for the measurement of the electrical transfer impedance through the neck in different directions. From the acquired data the global and individual conductivity is calculated as well as a 2D point spatial representation of the minimum impedance. The position information is shown together with classical EGG signals allowing a synchronous visual assessment of glottal area and larynx position. A first application to singing voice analysis is presented that indicate a high potential of the method for use as a non-invasive tool in the diagnosis of voice, speech, and swallowing disorders. KW - EGG KW - Transfer impedance KW - Tomography KW - Larynx position KW - Voice assessment Y1 - 2009 U6 - https://doi.org/10.1016/j.bspc.2009.03.004 SN - 1746-8108 VL - 4 IS - 3 SP - 221 EP - 228 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Frauenrath, Tobias A1 - Prothmann, Marcel A1 - Dieringer, Matthias A. A1 - Hezel, Fabian A1 - Renz, Wolfgang A1 - Kretschel, Kerstin A1 - Niendorf, Thoralf A1 - Schulz-Menger, Jeanette T1 - Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla—a pilot study N2 - Objectives Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T. Methods A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated. Results All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm. Conclusions This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T. Y1 - 2010 U6 - https://doi.org/10.1007/s00330-010-1888-2 SN - 0938-7994 VL - 20 SP - 2844 EP - 2852 PB - Springer CY - Berlin, Heidelberg ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Renz, Wolfgang A1 - de Geyer d'Orth, Thibaut A1 - Dieringer, Matthias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Prothmann, Marcel A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla JF - Journal of Cardiovascular Magnetic Resonance N2 - Background To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms. Results ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms. Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34). Conclusions The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T. KW - Interval Time Series KW - Image Quality Score KW - Image Quality Assessment KW - Sound Pressure Level KW - Cardiovascular Magnetic Resonance Y1 - 2010 U6 - https://doi.org/10.1186/1532-429X-12-67 SN - 1532-429X VL - 12 IS - 1 PB - Elsevier CY - Amsterdam ER -