TY - JOUR A1 - Miyamoto, K. A1 - Ichimura, H. A1 - Wagner, Torsten A1 - Yoshinobu, T. A1 - Schöning, Michael Josef T1 - Chemical Imaging of ion Diffusion in a Microfluidic Channel JF - Procedia Engineering N2 - The chemical imaging sensor is a chemical sensor which is capable of visualizing the spatial distribution of chemical species in sample solution. In this study, a novel measurement system based on the chemical imaging sensor was developed to observe the inside of a Y-shaped microfluidic channel while injecting two sample solutions from two branches. From the collected chemical images, it was clearly observed that the injected solutions formed laminar flows in the microfluidic channel. In addition, ion diffusion across the laminar flows was observed. This label-free method can acquire quantitative data of ion distribution and diffusion in microfluidic devices, which can be used to determine the diffusion coefficients, and therefore, the molecular weights of chemical species in the sample solution. Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.proeng.2012.09.289 SN - 1877-7058 N1 - Part of special issue "26th European Conference on Solid-State Transducers, EUROSENSOR 2012" IS - 47 SP - 886 EP - 889 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Kaneko, Kazumi A1 - Matsuo, Akira A1 - Wagner, Torsten A1 - Kanoh, Shiníchiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Miniaturized chemical imaging sensor system using an OLED display panel JF - Sensors and Actuators B: Chemical N2 - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current–voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated. KW - LAPS KW - Light-addressable potentiometric sensor KW - Chemical imaging sensor KW - Organic light-emitting diode display Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.snb.2011.02.029 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 82 EP - 87 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Mottaghy, Darius A1 - Dijkshoorn, Lydia T1 - Implementing an effective finite difference formulation for borehole heat exchangers into a heat and mass transport code JF - Renewable Energy N2 - We present an effective finite difference formulation for implementing and modeling multiple borehole heat exchangers (BHE) in the general 3-D coupled heat and flow transport code SHEMAT. The BHE with arbitrary length can be either coaxial or double U-shaped. It is particularly suitable for modeling deep BHEs which contain varying pipe diameters and materials. Usually, in numerical simulations, a fine discretization of the BHE assemblage is required, due to the large geometric aspect ratios involved. This yields large models and long simulation times. The approach avoids this problem by considering heat transport between fluid and the soil through pipes and grout via thermal resistances. Therefore, the simulation time can be significantly reduced. The coupling with SHEMAT is realized by introducing an effective heat generation. Due to this connection, it is possible to consider heterogeneous geological models, as well as the influence of groundwater flow. This is particularly interesting when studying the long term behavior of a single BHE or a BHE field. Heating and cooling loads can enter the model with an arbitrary interval, e.g. from hourly to monthly values. When dealing with large BHE fields, computing times can be further significantly reduced by focusing on the temperature field around the BHEs, without explicitly modeling inlet and outlet temperatures. This allows to determine the possible migration of cold and warm plumes due to groundwater flow, which is of particular importance in urban areas with a high BHE installation density. The model is validated against the existing BHE modeling codes EWS and EED. A comparison with monitoring data from a deep BHE in Switzerland shows a good agreement. Synthetic examples demonstrate the field of application of this model. KW - Borehole heat exchanger KW - Finite differences KW - Heat transport Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.renene.2012.02.013 SN - 0960-1481 VL - 45 SP - 59 EP - 71 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Murib, Mohammed S. A1 - Tran, Anh Quang A1 - Ceuninck, Ward de A1 - Schöning, Michael Josef A1 - Nesladek, Milos A1 - Serpengüzel, Ali A1 - Wagner, Patrick T1 - Analysis of an optical biosensor based on elastic light scattering from diamond-, glass-, and sapphire microspheres JF - Physica Status Solidi A N2 - Deoxyribonucleic acid (DNA) and protein recognition are now standard tools in biology. In addition, the special optical properties of microsphere resonators expressed by the high quality factor (Q-factor) of whispering gallery modes (WGMs) or morphology dependent resonances (MDRs) have attracted the attention of the biophotonic community. Microsphere-based biosensors are considered as powerful candidates to achieve label-free recognition of single molecules due to the high sensitivity of their WGMs. When the microsphere surface is modified with biomolecules, the effective refractive index and the effective size of the microsphere change resulting in a resonant wavelength shift. The transverse electric (TE) and the transverse magnetic (TM) elastic light scattering intensity of electromagnetic waves at 600 and 1400 nm are numerically calculated for DNA and unspecific binding of proteins to the microsphere surface. The effect of changing the optical properties was studied for diamond (refractive index 2.34), glass (refractive index 1.50), and sapphire (refractive index 1.75) microspheres with a 50 µm radius. The mode spacing, the linewidth of WGMs, and the shift of resonant wavelength due to the change in radius and refractive index, were analyzed by numerical simulations. Preliminary results of unspecific binding of biomolecules are presented. The calculated shift in WGMs can be used for biomolecules detection. Y1 - 2012 U6 - http://dx.doi.org/10.1002/pssa.201100795 SN - 1862-6319 N1 - Special Issue: "Fundamentals and Applications of Diamond" VL - 209 IS - 9 SP - 1804 EP - 1810 PB - Wiley-VCH CY - Weinheim ER - TY - CHAP A1 - Naujokat, Anke ED - Heynen, Hilde ED - Gosseye, Janina T1 - Leon Battista Alberti and the consonance of old and new T2 - Proceedings of the 2nd International conference of the European Architectural History Network, Brussels 31 May - 2 June 2012 Y1 - 2012 SN - 978-90-6569-102-6 SP - 182 EP - 184 PB - KVAB CY - Brüssel ER - TY - JOUR A1 - Nguyen, Nhu Huynh A1 - Duong, Minh Tuan A1 - Tran, Thanh Ngoc A1 - Pham, Phu Tinh A1 - Grottke, O. A1 - Tolba, R. A1 - Staat, Manfred T1 - Influence of a freeze–thaw cycle on the stress–stretch curves of tissues of porcine abdominal organs JF - Journal of Biomechanics N2 - The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze–thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze–thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines. KW - Autolysis KW - Decomposition KW - Freeze–thaw process KW - Spleen KW - Liver Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jbiomech.2012.07.008 SN - 1873-2380 VL - 45 IS - 14 SP - 2382 EP - 2386 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Nix, Yvonne A1 - Frotscher, Ralf A1 - Staat, Manfred ED - Eberhardsteiner, J. T1 - Implementation of the edge-based smoothed extended finite element method T2 - Proceedings 6th European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Vienna, Austria, September 10-14, 2012 Y1 - 2012 ER - TY - JOUR A1 - Nomdedeu, Mar Monsonis A1 - Willen, Christine A1 - Schieffer, Andre A1 - Arndt, Hartmut T1 - Temperature-dependent ranges of coexistence in a model of a two-prey-one-predator microbial food web JF - Marine Biology N2 - The objective of our study was to analyze the effects of temperature on the population dynamics of a three-species food web consisting of two prey bacteria (Pedobacter sp. and Acinetobacter johnsonii) and a protozoan predator (Tetrahymena pyriformis) as model organisms. We assessed the effects of temperature on the growth rates of all three species with the objective of developing a model with four differential equations based on the experimental data. The following hypotheses were tested at a theoretical level: Firstly, temperature changes can affect the dynamic behavior of a system by temperature-dependent parameters and interactions and secondly, food web response to temperature cannot be derived from the single species temperature response. The main outcome of the study is that temperature changes affect the parameter range where coexistence is possible within all three species. This has significant consequences on our ideas regarding the evaluation of effects of global warming. Y1 - 2012 U6 - http://dx.doi.org/10.1007/s00227-012-1966-x SN - 1432-1793 VL - 159 IS - 11 SP - 2423 EP - 2430 PB - Springer CY - Berlin ER - TY - JOUR A1 - Novacek, V. A1 - Tran, Thanh Ngoc A1 - Klinge, U. A1 - Tolba, R. H. A1 - Staat, Manfred A1 - Bronson, D. G. A1 - Miesse, A. M. A1 - Whiffen, J. A1 - Turquier, F. T1 - Finite element modelling of stapled colorectal end-to-end anastomosis : Advantages of variable height stapler design JF - Journal of Biomechanics N2 - The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge. KW - Variable height stapler design KW - Anastomotic leakage KW - Finite element modelling KW - End-to-end colorectal anastomosis KW - Surgical staplers Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jbiomech.2012.07.021 SN - 1873-2380 VL - 45 IS - 115 SP - 2693 EP - 2697 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Nötzold, K. A1 - Uphues, A. A1 - Wegener, R. A1 - Soter, S. A1 - Fink, K. A1 - Bragard, Michael A1 - Griessel, R. T1 - Inverter based test setup for LVRT verification of a full-scale 2 MW wind power converter T2 - EPE Joint Wind Energy and T&D Chapters Seminar : 28th and 29th of June 2012, in the Utzon Centre, Aalborg, Denmark ; papers, posters, presentations. - Session 2: Grid connection, compliance Y1 - 2012 PB - EPE Association CY - Brussels ER -