TY - BOOK A1 - Hüning, Felix T1 - The fundamentals of electrical engineering for mechatronics Y1 - 2014 SN - 978-3-11-034991-7 (Druckausg.) SN - 978-3-11-030840-2 (E-Book) PB - de Gruyter CY - Berlin ER - TY - CHAP A1 - Hüning, Felix T1 - Power semiconductors : key components for HEV/EV T2 - FISITA 2014 World Automotive Congress : 2 - 6 June, Maastricht, the Netherlands International Federation of Automotive Engineering Societies Y1 - 2014 N1 - Datenformat: PDF PB - KIVI CY - [s.l.] ER - TY - CHAP A1 - Janotte, N. A1 - Feckler, G. A1 - Kötter, Jens A1 - Decker, Stefan A1 - Herrmann, Ulf A1 - Schmitz, Mark A1 - Lüpfert, E. T1 - Dynamic performance evaluation of the HelioTrough® collector demonstration loop : towards a new benchmark in parabolic trough qualification T2 - SolarPACES International Conference 2013, Las Vegas, Nevada, USA, 17 - 20 September 2013 : [proceedings]. - Pt. 1. - (Energy procedia ; 49) Y1 - 2014 SN - 978-1-63266-904-9 U6 - http://dx.doi.org/10.1016/j.egypro.2014.03.012 SN - 1876-6102 N1 - Nebent.: Power and Chemical Energy Systems concentrating solar power SP - 109 EP - 117 PB - Curran CY - Red Hook, NY ER - TY - JOUR A1 - Jens, Otto A1 - Kaldenhoff, E. A1 - Kirschner-Hermanns, R. A1 - Mühl, Thomas A1 - Klinge, Uwe T1 - Elongation of textile pelvic floor implants under load is related to complete loss of effective porosity, thereby favoring incorporation in scar plates JF - Journal of biomedical materials research. Part A N2 - Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome. Y1 - 2014 U6 - http://dx.doi.org/10.1002/jbm.a.34767 SN - 1552-4965 VL - 102 IS - 4 SP - 1079 EP - 1084 PB - Wiley CY - New York ER - TY - CHAP A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram ED - Onate, E. T1 - Optimization of the flight style in ski jumping T2 - 11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20 - 25, 2014, Barcelona Y1 - 2014 N1 - Das Paper wurde nach der Konferenz überarbeitet. SP - 799 EP - 810 ER - TY - CHAP A1 - Kern, Alexander A1 - Braun, Christian T1 - Risk management according to IEC 62305-2 edition 2: 2010–12 assessment of structures with a risk of explosion T2 - 2014 International Conference on Lightning Protection (ICLP), Shanghai, China N2 - Risk management for structures with a risk of explosion should be considered very carefully when performing a risk analysis according to IEC 62305-2. In contrast to the 2006 edition of the standard, the 2010 edition describes the topic “Structures with a risk of explosion” in more detail. Moreover, in Germany separate procedures and parameters are defined for the risk analysis of structures with a risk of explosion (Supplement 3 of the German DIN EN 62305-2 standard). This paper describes the contents and the relevant calculations of this Supplement 3, together with a numerical example. Y1 - 2014 SP - 1237 EP - 1242 ER - TY - JOUR A1 - Khaydukova, M. M. A1 - Zadorozhnaya, O. A. A1 - Kirsanov, D. O. A1 - Iken, Heiko A1 - Rolka, David A1 - Schöning, Michael Josef A1 - Babain, V. A. A1 - Vlasov, Yu. G. A1 - Legin, A. V. T1 - Multivariate processing of atomic-force microscopy images for detection of the response of plasticized polymeric membranes JF - Russian journal of applied chemistry N2 - The possibility of using the atomic-force microscopy as a method for detection of the analytical signal from plasticized polymeric sensor membranes was analyzed. The surfaces of cadmium-selective membranes based on two polymeric matrices were examined. The digital images were processed with multivariate image analysis techniques. A correlation was found between the surface profile of an ion-selective membrane and the concentration of the ion in solution. Y1 - 2014 U6 - http://dx.doi.org/10.1134/S1070427214030112 SN - 1608-3296 (E-Journal); 1070-4272 (Print) VL - 87 IS - 3 SP - 307 EP - 314 PB - Springer CY - Dordrecht ER - TY - CHAP A1 - Kirchner, Patrick A1 - Reisert, Steffen A1 - Schöning, Michael Josef T1 - Calorimetric gas sensors for hydrogen peroxide monitoring in aseptic food processes T2 - Gas sensing fundamentals. (Springer Series on Chemical Sensors and Biosensors ; 15) N2 - For the sterilisation of aseptic food packages it is taken advantage of the microbicidal properties of hydrogen peroxide (H2O2). Especially, when applied in vapour phase, it has shown high potential of microbial inactivation. In addition, it offers a high environmental compatibility compared to other chemical sterilisation agents, as it decomposes into oxygen and water, respectively. Due to a lack in sensory detection possibilities, a continuous monitoring of the H2O2 concentration was recently not available. Instead, the sterilisation efficacy is validated using microbiological tests. However, progresses in the development of calorimetric gas sensors during the last 7 years have made it possible to monitor the H2O2 concentration during operation. This chapter deals with the fundamentals of calorimetric gas sensing with special focus on the detection of gaseous hydrogen peroxide. A sensor principle based on a calorimetric differential set-up is described. Special emphasis is given to the sensor design with respect to the operational requirements under field conditions. The state-of-the-art regarding a sensor set-up for the on-line monitoring and secondly, a miniaturised sensor for in-line monitoring are summarised. Furthermore, alternative detection methods and a novel multi-sensor system for the characterisation of aseptic sterilisation processes are described. KW - Calorimetric gas sensor KW - Hydrogen peroxide KW - Multi-sensor system Y1 - 2014 SN - 978-3-642-54518-4 (Print) ; 978-3-642-54519-1 (Online) U6 - http://dx.doi.org/10.1007/5346_2013_51 SP - 279 EP - 309 PB - Springer CY - Heidelberg ER - TY - CHAP A1 - Kirsch, Ansgar A1 - Felber, W. A1 - Marcher, Thomas A1 - Fuchs, W. T1 - Geotechnical challenges during design and construction of a ski resort in Azerbaijan T2 - Geotechnics of roads and railways : proceedings of the 15th Danube - European Conference on Geotechnical Engineering : 9-11 September 2014, Vienna, Austria Y1 - 2014 SN - 978‐3‐902593‐01‐6 SP - 757 EP - 762 PB - ÖIAV - Österreichischer Ingenieur- und Architekten-Verein CY - Wien ER - TY - BOOK A1 - Klinkel, Sven A1 - Butenweg, Christoph A1 - Lin, Gao A1 - Holtschoppen, Britta T1 - Seismic design of industrial facilities : Proceedings of the International Conference on Seismic Design of Industrial Facilities (SeDIF) / Sven Klinkel, Christoph Butenweg, Gao Lin, Britta Holtschoppen Editors Y1 - 2014 SN - 978-3-658-02809-1 (Print) ; 978-365-80281-0-7 (E-Book) U6 - http://dx.doi.org/10.1007/978-3-658-02810-7 PB - Springer Vieweg CY - Wiesbaden ER -