TY - CHAP A1 - Frauenrath, Tobias A1 - Gömmel, Andreas A1 - Butenweg, Christoph A1 - Otten, Mario A1 - Niendorf, Thoralf T1 - 3D mapping of vocal fold geometry during articulatory maneuvers using ultrashort echo time imaging at 3.0 T T2 - ISMRM-ESMRMB joint annual meeting 2010, Band 4 Y1 - 2010 SN - 978-1-617-82008-3 N1 - ISMRM-ESMRMB joint annual meeting 2010 : Stockholm, Sweden, 1 - 7 May 2010 SP - 3087 PB - Curran CY - Red Hook, NY ER - TY - CHAP A1 - Gömmel, Andreas A1 - Niendorf, Thoralf A1 - Frauenrath, Tobias A1 - Otten, Mario A1 - Butenweg, Christoph A1 - Kob, Malte T1 - 3D vocal fold geometry mapping using Magnetic Resonance Imaging T2 - Fortschritte der Akustik : 36. Deutsche Jahrestagung für Akustik, Band 1 Y1 - 2010 SN - 978-3-9808659-8-2 N1 - Fortschritte der Akustik : 36. Deutsche Jahrestagung für Akustik ; 15.-18. März 2010, Berlin SP - 271 EP - 272 PB - Deutsche Gesellschaft für Akustik CY - Berlin ER - TY - GEN A1 - Dieringer, Matthias A. A1 - Renz, Wolfgang A1 - Lindel, Tomasz A1 - Seifert, Frank A1 - Frauenrath, Tobias A1 - Waiczies, Helmar A1 - von Knobelsdorff-Brenkhoff, Florian A1 - Santoro, Davide A1 - Hoffmann, Werner A1 - Ittermann, Bernd A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - 4CH TX/RX Surface Coil for 7T: Design, Optimization and Application for Cardiac Function Imaging T2 - 2010 ISMRM-ESMRMB joint annual meeting N2 - Practical impediments of ultra high field cardiovascular MR (CVMR) can be catalogued in exacerbated magnetic field and radio frequency (RF) inhomogeneities, susceptibility and off-resonance effects, conductive and dielectric effects in tissue, and RF power deposition constraints, which all bear the potential to spoil the benefit of CVMR at 7T. Therefore, a four element cardiac transceive surface coil array was developed. Cardiac imaging provided clinically acceptable signal homogeneity with an excellent blood myocardium contrast. Subtle anatomic structures, such as pericardium, mitral and tricuspid valves and their apparatus, papillary muscles, and trabecles were accurately delineated. Y1 - 2010 SN - 1545-4428 N1 - ISMRM-ESMRMB joint annual meeting, 1 - 7 May 2010, Stockholm, Sweden ER - TY - JOUR A1 - Butenweg, Christoph T1 - Bewertung der Erdbebensicherheit von bestehenden Bauwerken JF - Österreichische Ingenieur- und Architekten-Zeitschrift : ÖIAZ ; Zeitschr. d. ÖIAV / Österreichischer Ingenieur- und Architekten-Verein Y1 - 2010 SN - 0721-9415 VL - 155 IS - 1-3 und 4-6 SP - 11 EP - 17 PB - ÖAIV CY - Wien ER - TY - GEN A1 - Frauenrath, Tobias A1 - Becker, Meike A1 - Hezel, Fabian A1 - Krombach, Gabriele A. A1 - Kremer, Ute A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Comparison of Left Function Assessment Using Phonocardiogram and Electrocardiogram Triggered 2D SSFP CINE MR Imaging at 1.5 T and 3.0 T T2 - 2010 ISMRM-ESMRMB joint annual meeting N2 - As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to distortions and mistriggering increases and with it the motivation for a cardiac triggering alternative. Hence, this study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects at 1.5T and 3.0T. Y1 - 2010 SN - 1545-4428 N1 - ISMRM-ESMRMB joint annual meeting, 1 - 7 May 2010, Stockholm, Sweden ER - TY - JOUR A1 - Becker, Meike A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Krombach, Gabriele A. A1 - Kremer, Ute A1 - Koppers, Benedikt A1 - Butenweg, Christoph A1 - Goemmel, Andreas A1 - Utting, Jane F. A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T JF - European Radiology N2 - Objective: As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n=14). Methods: Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT’s performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Results: Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct Rwave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects—even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), endsystolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived fromVCG-triggered acquisitions (1.5 T: ESVVCG=(56± 17) ml, EDVVCG=(151±32)ml, LVMVCG=(97±27) g, SVVCG=(94± 19)ml, EFVCG=(63±5)% cf. ESVACT= (56±18) ml, EDVACT=(147±36) ml, LVMACT=(102±29) g, SVACT=(91± 22) ml, EFACT=(62±6)%; 3.0 T: ESVVCG=(55±21) ml, EDVVCG=(151±32) ml, LVMVCG=(101±27) g, SVVCG=(96±15) ml, EFVCG=(65±7)% cf. ESVACT=(54±20) ml, EDVACT=(146±35) ml, LVMACT= (101±30) g, SVACT=(92±17) ml, EFACT=(64±6)%). Conclusions: ACT’s intrinsic insensitivity to interference from electromagnetic fields renders KW - Magnetic resonance imaging (MRI) KW - MR-stethoscope KW - Magnetic field strength KW - Left ventriular function KW - Cardiovascular MRI Y1 - 2010 U6 - https://doi.org/10.1007/s00330-009-1676-z SN - 1432-1084 (Onlineausgabe) SN - 0938-7994 (Druckausgabe) VL - 20 SP - 1344 EP - 1355 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Die dynamische Blitzkugel : Wahrscheinlichkeitsberechnung für Blitzeinschläge in Gebäude JF - De Fachzeitschrift für das Elektrohandwerk. 13-14 (2010) Y1 - 2010 SP - 24 EP - 29 ER - TY - JOUR A1 - Butenweg, Christoph A1 - Fäcke, Andreas A1 - Fehling, Ekkehard A1 - Gellert, Christoph A1 - Gierga, Michael A1 - Meyer, Udo A1 - Rütschlin, Andreas H. A1 - Stürz, Jochen T1 - Energieeffizient und erdbebensicher Bauen mit monolithischem Ziegelmauerwerk JF - Mauerwerk : European journal of masonry N2 - Moderne Bauwerke müssen heute eine hohe energetische Leistungsfähigkeit aufweisen und gleichzeitig alle einwirkenden Lasten sicher abtragen. Dies stellt insbesondere in Erdbebengebieten hohe Anforderungen an die verwendeten Baustoffe. Am baupraktischen Beispiel einer Doppelhaushälfte wird demonstriert, dass die Symbiose aus energieeffizientem und gleichzeitig erdbebensicherem Bauen in der höchsten deutschen Erdbebenzone mit monolithischem Ziegelmauerwerk gut realisierbar ist. Als Ziegelmauerwerk werden für die Außenwände wärmetechnisch optimierte Hochlochziegel verwendet, die sowohl die Anforderungen der Energieeinsparverordnung 2009 als auch die Anforderungen an Mauerwerkbaustoffe nach den aktuellen Erdbebennormen erfüllen. Der Erdbebennachweis der Doppelhaushälfte erfolgt mit einem nichtlinearen Nachweisverfahren, das für eine einfache praktische Anwendung programmtechnisch umgesetzt wurde. Für den Nachweis wurden aus zyklischen Schubwandversuchen ermittelte Last-Verformungskurven verwendet. Das gesamte in Deutschland noch nicht normativ geregelte Nachweiskonzept wurde im Rahmen einer Zustimmung im Einzelfall geprüft und genehmigt. Y1 - 2010 U6 - https://doi.org/10.1002/dama.201000456 SN - 1432-3427 VL - 14 IS - 1 SP - 3 EP - 9 PB - Ernst & Sohn CY - Berlin ER - TY - CHAP A1 - Butenweg, Christoph A1 - Gellert, Christoph A1 - Meyer, Udo T1 - Erdbebenbemessung bei Mauerwerksbauten T2 - Mauerwerk-Kalender 2010: Normen für Bemessung und Ausführung Y1 - 2010 SN - 3-433-60040-6 ; 978-3-433-60040-5 U6 - https://doi.org/10.1002/9783433600405.ch7 SP - 141 EP - 167 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Mottaghy, Darius A1 - Pechnig, Renate A1 - Taugs, Renate A1 - Kröger, Jens A1 - Thomsen, Claudia A1 - Hesse, Fabian A1 - Liebsch-Doerschner, Thomas T1 - Erstellung eines geothermischen Modells für Teile Hamburgs und anliegende Gebiete JF - BBR - Fachmagazin für Brunnen- und Leitungsbau Y1 - 2010 SN - 1611-1478 VL - 61 IS - 12 SP - 52 EP - 59 PB - WVGW Wirtschafts- u. Verl.Ges. Gas und Wasser CY - Bonn ER -