TY - CHAP A1 - Artmann, Gerhard A1 - Stadler, Andreas M. A1 - Embs, Jan P. A1 - Zaccai, Giuseppe A1 - Büldt, Georg A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül T1 - The crucial role of water in a phase transition of hemoglobin at body temperature : [abstract] N2 - The observation of a temperature transition of hemoglobin occurring at a critical temperature close to body temperature KW - Hämoglobin KW - Erythrozyt KW - Körpertemperatur Y1 - 2010 ER - TY - CHAP A1 - Stadler, Andreas M. A1 - Embs, Jan P. A1 - Zerlin, Kay A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Zaccai, Joe A1 - Büldt, Georg T1 - Temperature transitions of hemoglobin and cytosolic water diffusion in human red blood cells : [poster] N2 - Background Hemoglobin interactions in red blood cells Hemoglobin dynamics in human red blood cells Diffusion of H2O in red blood cells KW - Erythrozyt KW - Hämoglobin KW - cytosolic water diffusion KW - hemoglobin dynamics Y1 - 2007 ER - TY - CHAP A1 - Kreyer, Jörg A1 - Stollenwerk, Dominik A1 - Schöning, Michael Josef T1 - Tagung des Forschernachwuchses der FH Aachen 20. November 2013 / ed.: J. Kreyer, D. Stollenwerk, M. J. Schöning Y1 - 2013 PB - FH Aachen CY - Aachen ER - TY - CHAP A1 - Pijanowska, Dorota G. A1 - Remiszewska, Elzbieta A1 - Pederzolli, Cecilia A1 - Lunelli, Lorenzo A1 - Vendano, Michele A1 - Canteri, Roberto A1 - Dudzinski, Konrad A1 - Kruk, Jerzy A1 - Torbicz, Wladyslaw T1 - Surface modification for microreactor fabrication N2 - In this paper, methods of surface modification of different supports, i.e. glass and polymeric beads for enzyme immobilisation are described. The developed method of enzyme immobilisation is based on Schiff’s base formation between the amino groups on the enzyme surface and the aldehyde groups on the chemically modified surface of the supports. The surface of silicon modified by APTS and GOPS with immobilised enzyme was characterised by atomic force microscopy (AFM), time-of-flight secondary ion mass spectroscopy (ToF-SIMS) and infrared spectroscopy (FTIR). The supports with immobilised enzyme (urease) were also tested in combination with microreactors fabricated in silicon and Perspex, operating in a flow-through system. For microreactors filled with urease immobilised on glass beads (Sigma) and on polymeric beads (PAN), a very high and stable signal (pH change) was obtained. The developed method of urease immobilisation can be stated to be very effective. KW - Biosensor KW - Microreactors KW - surface modification KW - enzyme immobilisation KW - lab-on-a-chip Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1480 ER - TY - CHAP A1 - Kraft, Bodo A1 - Nagl, Manfred T1 - Support of Conceptual Design in Civil Engineering by Graph-based Tools N2 - WS GTaD-2003 - The 1st Workshop on Graph Transformations and Design ed Grabska, E., Seite 6-7, Jagiellonian University Krakow. 2 pages KW - CAD KW - CAD KW - Bauingenieurwesen KW - CAD KW - civil engineering Y1 - 2003 ER - TY - CHAP A1 - Srivastava, Alok A1 - Singh, Virendra A1 - Dhand, Chetna A1 - Kaur, Manindar A1 - Singh, Tejvir A1 - Witte, Katrin A1 - Scherer, Ulrich W. T1 - Study of swift heavy ion modified conduction polymer composites for application as gas sensor N2 - A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas. KW - Biosensor KW - Conducing polymer KW - ammonia gas sensors KW - swift heavy ions KW - polymer composites Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1345 ER - TY - CHAP A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül A1 - Nojima, H. A1 - Artmann, Gerhard T1 - Some peculiarities of application of cluster ions generated by plasma in respect of indoor air purification :[abstract] N2 - Recently, the SHARP Corporation, Japan, has developed the world’s first "Plasma Cluster Ions (PCI)" air purification technology using plasma discharge to generate cluster ions. The new plasma cluster device releases positive and negative ions into the air, which are able to decompose and deactivate harmful airborne substances by chemical reactions. Because cluster ions consist of positive and negative ions that normally exist in the natural world, they are completely harmless and safe to humans. The amount of ozone generated by cluster ions is less than 0.01 ppm, which is significantly less than the 0.05-ppm standard for industrial operations and consumer electronics. This amount, thus, has no harming effects whatsoever on the human body. But particular properties and chemical processes in PCI treatment are still under study. It has been shown that PCI in most cases show strongly pronounced irreversible killing effects in respect of airborne microflora due to free-radical induced reactions and can be considered as a potent technology to disinfect both home, medical and industrial appliances. KW - Clusterion KW - Raumluft KW - Luftreiniger KW - Plasmacluster ion technology KW - Air purification Y1 - 2003 ER - TY - CHAP A1 - Staat, Manfred A1 - Duong, Minh Tuan T1 - Smoothed Finite Element Methods for Nonlinear Solid Mechanics Problems: 2D and 3D Case Studies T2 - Proceedings of the National Science and Technology Conference on Mechanical - Transportation Engineering (NSCMET 2016), 13th October 2016, Hanoi, Vietnam, Vol.2 N2 - The Smoothed Finite Element Method (SFEM) is presented as an edge-based and a facebased techniques for 2D and 3D boundary value problems, respectively. SFEMs avoid shortcomings of the standard Finite Element Method (FEM) with lower order elements such as overly stiff behavior, poor stress solution, and locking effects. Based on the idea of averaging spatially the standard strain field of the FEM over so-called smoothing domains SFEM calculates the stiffness matrix for the same number of degrees of freedom (DOFs) as those of the FEM. However, the SFEMs significantly improve accuracy and convergence even for distorted meshes and/or nearly incompressible materials. Numerical results of the SFEMs for a cardiac tissue membrane (thin plate inflation) and an artery (tension of 3D tube) show clearly their advantageous properties in improving accuracy particularly for the distorted meshes and avoiding shear locking effects. Y1 - 2016 SP - 440 EP - 445 ER - TY - CHAP A1 - Frotscher, Ralf A1 - Duong, Minh Tuan A1 - Staat, Manfred T1 - Simulating beating cardiomyocytes with electromechanical coupling T2 - II. International Conference on Biomedical Technology : 28-30 October 2015 Hannover, Germany / T. Lenarz, P. Wriggers (Eds.) Y1 - 2015 SP - 1 EP - 2 ER - TY - CHAP A1 - Barek, Jiri A1 - Fischer, Jan A1 - Navratil, Tomas A1 - Peckova, Karolina A1 - Yosypchuk, Bogdan T1 - Silver solid amalgam electrodes as sensors for chemical carcinogens N2 - The applicability of differential pulse voltammetry (DPV) and adsorptive stripping voltammetry (AdSV) at a non-toxic meniscus-modified silver solid amalgam electrode (m-AgSAE) for the determination of trace amounts of genotoxic substances was demonstrated on the determination of micromolar and submicromolar concentrations of 3-nitrofluoranthene using methanol - 0.01 mol L-1 NaOH (9:1) mixture as a base electrolyte and of Ostazine Orange using 0.01 mol L-1 NaOH as a base electrolyte. KW - Biosensor KW - Solid amalgam electrodes KW - voltammetry KW - carcinogens KW - 3-nitrofluoranthene KW - Ostazine Orange Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1554 ER -