TY - JOUR A1 - Bung, Daniel Bernhard A1 - Valero, Daniel T1 - Optical flow estimation in aerated flows JF - Journal of Hydraulic Research N2 - Optical flow estimation is known from Computer Vision where it is used to determine obstacle movements through a sequence of images following an assumption of brightness conservation. This paper presents the first study on application of the optical flow method to aerated stepped spillway flows. For this purpose, the flow is captured with a high-speed camera and illuminated with a synchronized LED light source. The flow velocities, obtained using a basic Horn–Schunck method for estimation of the optical flow coupled with an image pyramid multi-resolution approach for image filtering, compare well with data from intrusive conductivity probe measurements. Application of the Horn–Schunck method yields densely populated flow field data sets with velocity information for every pixel. It is found that the image pyramid approach has the most significant effect on the accuracy compared to other image processing techniques. However, the final results show some dependency on the pixel intensity distribution, with better accuracy found for grey values between 100 and 150. Y1 - 2016 U6 - https://doi.org/10.1080/00221686.2016.1173600 VL - 54 IS - 5 SP - 575 EP - 580 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Niedermeier, Jana A1 - Penner, Crystal A1 - Usherovich, Samuel A1 - Bélanger-Champagne, Camille A1 - Paulßen, Elisabeth A1 - Hoehr, Cornelia T1 - Optical Fibers as Dosimeter Detectors for Mixed Proton/Neutron Fields - A Biological Dosimeter JF - electronics N2 - In recent years, proton therapy has gained importance as a cancer treatment modality due to its conformality with the tumor and the sparing of healthy tissue. However, in the interaction of the protons with the beam line elements and patient tissues, potentially harmful secondary neutrons are always generated. To ensure that this neutron dose is as low as possible, treatment plans could be created to also account for and minimize the neutron dose. To monitor such a treatment plan, a compact, easy to use, and inexpensive dosimeter must be developed that not only measures the physical dose, but which can also distinguish between proton and neutron contributions. To that end, plastic optical fibers with scintillation materials (Gd₂O₂S:Tb, Gd₂O₂S:Eu, and YVO₄:Eu) were irradiated with protons and neutrons. It was confirmed that sensors with different scintillation materials have different sensitivities to protons and neutrons. A combination of these three scintillators can be used to build a detector array to create a biological dosimeter. KW - biological dosimeter KW - Bragg peak KW - relative dosimetry KW - optical fibers KW - proton therapy KW - protons KW - neutrons Y1 - 2023 U6 - https://doi.org/10.3390/electronics12020324 SN - 2079-9292 N1 - This article belongs to the Special Issue "Applications of Optical Fiber Sensors" VL - 12 IS - 2 PB - MDPI CY - Basel ER - TY - JOUR A1 - Hagemann, Hans-Jürgen A1 - Gudat, W. A1 - Kunz, C. T1 - Optical constants from the far infrared to the X-ray region: Mg, Al, Cu, Ag, Au, Bi, C, and Al₂O₃ JF - Journal of the Optical Society of America (JOSA) Y1 - 1975 SN - 0030-3941 U6 - https://doi.org/10.1364/JOSA.65.000742 VL - 65 IS - 6 SP - 742 EP - 744 PB - Optical Society of America CY - New York ER - TY - JOUR A1 - Micili, Serap C. A1 - Valter, Markus A1 - Oflaz, Hakan A1 - Ozogul, Candan A1 - Linder, Peter A1 - Föckler, Nicole A1 - Artmann, Gerhard A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül T1 - Optical coherence tomography : a potential tool to predict premature rupture of fetal membranes JF - Proceedings of the Institution of Mechanical Engineers. Part H : Journal of engineering in medicine Y1 - 2013 SN - 0046-2039 (Print) ; 2041-3033 (E-Journal) VL - Vol. 227 IS - No. 4 SP - 393 EP - 401 PB - Sage CY - London ER - TY - JOUR A1 - Hough, Lindsay B. A1 - Nalwalk, Julia W. A1 - Ding, Xinxin A1 - Scheer, Nico T1 - Opioid Analgesia in P450 Gene Cluster Knockout Mice: A Search for Analgesia-Relevant Isoforms JF - Drug Metabolism and Disposition Y1 - 2015 U6 - https://doi.org/10.1124/dmd.115.065490 SN - 1521-009x VL - 43 IS - 9 SP - 1326 EP - 1330 ER - TY - JOUR A1 - Stulpe, Werner T1 - Operator JF - Compendium of Quantum Physics : concepts, experiments, history and philosophy / Daniel Greenberger ... ed. Y1 - 2009 SN - 978-3-540-70622-9 SP - 440 EP - 444 PB - Springer CY - Berlin ER - TY - JOUR A1 - Neu, Eugen A1 - Janser, Frank A1 - Khatibi, Akbar A. A1 - Braun, Carsten A1 - Orifici, Adrian C. T1 - Operational Modal Analysis of a wing excited by transonic flow JF - Aerospace Science and Technology N2 - Operational Modal Analysis (OMA) is a promising candidate for flutter testing and Structural Health Monitoring (SHM) of aircraft wings that are passively excited by wind loads. However, no studies have been published where OMA is tested in transonic flows, which is the dominant condition for large civil aircraft and is characterized by complex and unique aerodynamic phenomena. We use data from the HIRENASD large-scale wind tunnel experiment to automatically extract modal parameters from an ambiently excited wing operated in the transonic regime using two OMA methods: Stochastic Subspace Identification (SSI) and Frequency Domain Decomposition (FDD). The system response is evaluated based on accelerometer measurements. The excitation is investigated from surface pressure measurements. The forcing function is shown to be non-white, non-stationary and contaminated by narrow-banded transonic disturbances. All these properties violate fundamental OMA assumptions about the forcing function. Despite this, all physical modes in the investigated frequency range were successfully identified, and in addition transonic pressure waves were identified as physical modes as well. The SSI method showed superior identification capabilities for the investigated case. The investigation shows that complex transonic flows can interfere with OMA. This can make existing approaches for modal tracking unsuitable for their application to aircraft wings operated in the transonic flight regime. Approaches to separate the true physical modes from the transonic disturbances are discussed. Y1 - 2016 U6 - https://doi.org/10.1016/j.ast.2015.11.032 SN - 1270-9638 VL - 49 SP - 73 EP - 79 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Havermann, Marc A1 - Seiler, F. A1 - Boller, F. A1 - Mangold, P. T1 - Operation of the ISL transonic shock tube in a high subsonic flow regime / Seiler, F. ; Havermann, M. ; Boller, F. ; Mangold, P. ; Takayama K. JF - Shock Waves : Proceedings of the 24th International Symposium on Shock Waves Beijing, China July 11-16, 2004 / edited by Z. Jiang Y1 - 2005 SN - 978-3-540-22497-6 SP - 307 EP - 312 PB - Springer CY - Berlin ER - TY - JOUR A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Schäfer, Lena C. A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Maderwald, Stefan T1 - Open design eight-channel transmit/receive coil for high-resolution and real-time ankle imaging at 7 T JF - Medical Physics N2 - Purpose: At 1.5 T, real-time MRI of joint movement has been shown to be feasible. However, 7 T, provides higher SNR and thus an improved potential for parallel imaging acceleration. The purpose of this work was to build an open, U-shaped eight-channel transmit/receive microstrip coil for 7 T MRI to enable high-resolution and real-time imaging of the moving ankle joint. Methods: A U-shaped eight-channel transmit/receive array for the human ankle was built.urn:x-wiley:00942405:mp3399:equation:mp3399-math-0001-parameters and urn:x-wiley:00942405:mp3399:equation:mp3399-math-0002-factor were measured. SAR calculations of different ankle postures were performed to ensure patient safety. Inhomogeneities in the transmit field consequent to the open design were compensated for by the use of static RF shimming. High-resolution and real-time imaging was performed in human volunteers. Results: The presented array showed good performance with regard to patient comfort and image quality. High acceleration factors of up to 4 are feasible without visible acceleration artifacts. Reasonable image homogeneity was achieved with RF shimming. Conclusions: Open, noncylindrical designs for transmit/receive coils are practical at 7 T and real-time imaging of the moving joint is feasible with the presented coil design. Y1 - 2011 U6 - https://doi.org/10.1118/1.3553399 SN - 2473-4209 VL - 38 IS - 3 SP - 1162 EP - 1167 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Wagner, Torsten A1 - Beging, Stefan A1 - Rotter, L. A1 - Poghossian, Arshak A1 - Biselli, Manfred A1 - Zang, Werner A1 - Schöning, Michael Josef T1 - Online-Messsysteme für die automatisierte Charakterisierung von feldeffektbasierten Biosensoren JF - 8. Dresdner Sensor-Symposium : Sensoren für Umwelt, Klima und Sicherheit, Biosensoren und Biosysteme, Sensoren und Sensorsysteme für die Prozesstechnik, Trends in der Sensortechnik, Materialentwicklung für die Sensorik; 8. Dresdner Sensor-Symposium, 10. - 12. Dezember 2007, Dresden / Gerald Gerlach ... (Hg.) Y1 - 2007 SN - 978-3-940046-45-1 N1 - Dresdner Sensor-Symposium <8, 2007, Dresden> ; Dresdner Beiträge zur Sensorik ; 29 SP - 257 EP - 260 PB - TUDpress, Verl. der Wissenschaften CY - Dresden ER -