TY - JOUR A1 - Paulßen, Elisabeth A1 - Kong, Shushu A1 - Arciszewski, Pawel A1 - Wielbalck, Swantje A1 - Abram, Ulrich T1 - Aryl and NHC Compounds of Technetium and Rhenium JF - Journal of the American Chemical Society N2 - Air- and water-stable phenyl complexes with nitridotechnetium(V) cores can be prepared by straightforward procedures. [TcNPh2(PPh3)2] is formed by the reaction of [TcNCl2(PPh3)2] with PhLi. The analogous N-heterocyclic carbene (NHC) compound [TcNPh2(HLPh)2], where HLPh is 1,3,4-triphenyl-1,2,4-triazol-5-ylidene, is available from (NBu4)[TcNCl4] and HLPh or its methoxo-protected form. The latter compound allows the comparison of different Tc–C bonds within one compound. Surprisingly, the Tc chemistry with such NHCs does not resemble that of corresponding Re complexes, where CH activation and orthometalation dominate. Y1 - 2012 U6 - https://doi.org/10.1021/ja3033718 SN - 1520-5126 VL - 134 IS - 22 SP - 9118 EP - 9121 PB - ACS Publications CY - Washington, DC ER - TY - JOUR A1 - Wilke, Thomas T1 - Architekturzeichnung als Instrument der Theoriebildung. Lineamenta vs. Portraicture – Architekturdarstellung zwischen Wissenschaft und Öffentlichkeit. Tagung des DFG-Netzwerks-Schnittstelle Bild in Zusammenarbeit mit dem Lehrstuhl für Kunstgeschichte der Universität Regensburg, 28.4.2012. JF - Kunstchronik Y1 - 2012 SN - 0023-5474 VL - 65 IS - 9/10 SP - 494 EP - 499 PB - Fachverlag Hans Carl CY - Nürnberg ER - TY - JOUR A1 - Pieper, Martin A1 - Klein, Peter T1 - Application of simple, periodic homogenization techniques to non-linear heat conduction problems in non-periodic, porous media JF - Heat mass transfer N2 - Often, detailed simulations of heat conduction in complicated, porous media have large runtimes. Then homogenization is a powerful tool to speed up the calculations by preserving accurate solutions at the same time. Unfortunately real structures are generally non-periodic, which requires unpractical, complicated homogenization techniques. We demonstrate in this paper, that the application of simple, periodic techniques to realistic media, that are just close to periodic, gives accurate, approximative solutions. In order to obtain effective parameters for the homogenized heat equation, we have to solve a so called “cell problem”. In contrast to periodic structures it is not trivial to determine a suitable unit cell, which represents a non-periodic media. To overcome this problem, we give a rule of thumb on how to choose a good cell. Finally we demonstrate the efficiency of our method for virtually generated foams as well as real foams and compare these results to periodic structures. Y1 - 2012 U6 - https://doi.org/10.1007/s00231-011-0879-4 SN - 0947-7411 VL - 48 IS - 2 SP - 291 EP - 300 PB - Springer CY - Berlin ER - TY - CHAP A1 - Reisgen, Uwe A1 - Schleser, Markus A1 - Abdurakhmanov, Aydemir A1 - Gumenyuk, Andrej T1 - Application of electron beam welding to fabrication of steel-aluminium dissimilar joint T2 - Beam technologies & laser application : proceedings of the VII international conference, Saint Petersburg, Sept. 18-21, 2012 Y1 - 2012 SP - 265 EP - 279 PB - Publ. House CY - Saint Petersburg ER - TY - CHAP A1 - Frotscher, Ralf A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred ED - Eberhardsteiner, J. T1 - Application of an edge-based smoothed finite element method on geometrically non-linear plates of non-linear material T2 - Proceedings European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Y1 - 2012 N1 - 6th European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Vienna, Austria, September 10-14, 2012 ER - TY - CHAP A1 - Borggrafe, Andreas A1 - Ohndorf, Andreas A1 - Dachwald, Bernd A1 - Seboldt, Wolfgang T1 - Analysis of interplanetary solar sail trajectories with attitude dynamics T2 - Dynamics and Control of Space Systems 2012 N2 - We present a new approach to the problem of optimal control of solar sails for low-thrust trajectory optimization. The objective was to find the required control torque magnitudes in order to steer a solar sail in interplanetary space. A new steering strategy, controlling the solar sail with generic torques applied about the spacecraft body axes, is integrated into the existing low-thrust trajectory optimization software InTrance. This software combines artificial neural networks and evolutionary algorithms to find steering strategies close to the global optimum without an initial guess. Furthermore, we implement a three rotational degree-of-freedom rigid-body attitude dynamics model to represent the solar sail in space. Two interplanetary transfers to Mars and Neptune are chosen to represent typical future solar sail mission scenarios. The results found with the new steering strategy are compared to the existing reference trajectories without attitude dynamics. The resulting control torques required to accomplish the missions are investigated, as they pose the primary requirements to a real on-board attitude control system. Y1 - 2012 SN - 978-0-87703-587-9 SP - 1553 EP - 1569 PB - Univelt Inc CY - San Diego ER - TY - JOUR A1 - Murib, Mohammed S. A1 - Tran, Anh Quang A1 - Ceuninck, Ward de A1 - Schöning, Michael Josef A1 - Nesladek, Milos A1 - Serpengüzel, Ali A1 - Wagner, Patrick T1 - Analysis of an optical biosensor based on elastic light scattering from diamond-, glass-, and sapphire microspheres JF - Physica Status Solidi A N2 - Deoxyribonucleic acid (DNA) and protein recognition are now standard tools in biology. In addition, the special optical properties of microsphere resonators expressed by the high quality factor (Q-factor) of whispering gallery modes (WGMs) or morphology dependent resonances (MDRs) have attracted the attention of the biophotonic community. Microsphere-based biosensors are considered as powerful candidates to achieve label-free recognition of single molecules due to the high sensitivity of their WGMs. When the microsphere surface is modified with biomolecules, the effective refractive index and the effective size of the microsphere change resulting in a resonant wavelength shift. The transverse electric (TE) and the transverse magnetic (TM) elastic light scattering intensity of electromagnetic waves at 600 and 1400 nm are numerically calculated for DNA and unspecific binding of proteins to the microsphere surface. The effect of changing the optical properties was studied for diamond (refractive index 2.34), glass (refractive index 1.50), and sapphire (refractive index 1.75) microspheres with a 50 µm radius. The mode spacing, the linewidth of WGMs, and the shift of resonant wavelength due to the change in radius and refractive index, were analyzed by numerical simulations. Preliminary results of unspecific binding of biomolecules are presented. The calculated shift in WGMs can be used for biomolecules detection. Y1 - 2012 U6 - https://doi.org/10.1002/pssa.201100795 SN - 1862-6319 N1 - Special Issue: "Fundamentals and Applications of Diamond" VL - 209 IS - 9 SP - 1804 EP - 1810 PB - Wiley-VCH CY - Weinheim ER - TY - GEN A1 - Stadtmüller, R. A1 - Wollny, S. A1 - Tippkötter, Nils A1 - Ulber, Roland T1 - Amplifikation und Einsatz von ssDNA-Aptameren T2 - Chemie Ingenieur Technik N2 - Die wachsende Produktpalette von z. B. Pharmazeutika geht mit einer steigenden Nachfrage für hochsensitive/schonende Aufreinigungstechniken einher. Bisherige Verfahren führen oft zu geringer Reinheit und verminderter Bioaktivität, zeigen eine Limitation der Analytengröße oder bedingen dessen Modifikation. Durch die Kombination von mikroskaligen Magnetpartikeln und spezifisch wechselwirkenden Einzelstrang-DNA-Oligonukleotiden, den sog. ssDNA-Aptameren, sind eine höhere Selektivität/Reinheit und eine Automatisierung möglich. In diesem Kontext werden zum einen ssDNA-Amplifikationstechniken und zum anderen der praktische Einsatz von Aptameren in einer Magnetseparation vorgestellt. Die ssDNA-Synthese basiert auf einem In-vivo-dsDNA-Produktionsschritt mittels eines rekombinanten Escherichia coli. Die als High-copy-Plasmid organisierte Sequenz wird in vitro durch Kombination verschiedener enzymatischer Reaktionen in die funktionelle ssDNA überführt. Diese Technik bedingt nur minimale Instrumentierung bzw. Prozessregelung. Die zweite Synthesetechnik wird in Form eines In-vitro-Amplifikationsverfahrens realisiert und beruht auf dem Prinzip einer PCR (Potenzial zu einer Automatisierung bzw. Miniaturisierung). Die gewonnenen Aptamere werden im Anschluss in einem auf Magnetpartikeln basierten Trennverfahren zur Isolationvon 6xHis-tag-Proteinen bezüglich ihrer Eigenschaften untersucht. Y1 - 2012 U6 - https://doi.org/10.1002/cite.201250112 SN - 0009-286X SN - 1522-2640 (eISSN) N1 - ProcessNet-Jahrestagung 2012 und 30. DECHEMA-Jahrestagung der Biotechnologen, 10. – 13. September 2012, Karlsruhe VL - 84 IS - 8 SP - 1294 PB - Wiley-VCH CY - Weinheim ER - TY - GEN A1 - Tippkötter, Nils A1 - Staub, C. A1 - Sohling, U. A1 - Ruf, N. A1 - Ulber, Roland T1 - Adsorptive Aufreinigung von Molkeproteinen T2 - Chemie Ingenieur Technik N2 - In der Molkeverarbeitung dominieren Membranfiltrationsverfahren die Prozessführung. Hierbei werden üblicherweise Aufkonzentrierungen der Proteine und deren Trennung von dem Milchzucker Lactose durchgeführt. Der Prozess der adsorptiven Aufreinigung soll als kostengünstige Alternative zu den bisher gebräuchlichen Verfahren dienen. Weiterhin eröffnet sich durch das Verfahren die Möglichkeit, einzelne Proteinfraktionen während der Verarbeitung anzureichern. Als Proteinquellen wurden für die Untersuchungen Modellproteine, Lösungen aus Molkenproteinisolat, Dünnmolke und Molkekonzentrat verwendet. Die Eignung zur Proteinbindung wurden an Tonmaterialien, Silicaten und y-Aluminiumoxiden in Pulverform, in Form von Granulaten sowie Extrudaten als auch sphärischen Partikeln überprüft. Adsorbentien aus Bentonit/Silica und c-Aluminiumoxid können sowohl a-Lactalbumin (aLA) als auch b-Lactoglobulin (bLG) binden, wohingegen Materialien aus Siliciumoxid lediglich ein starkes Adsorptionsverhalten gegenüber bLG zeigen. Mischmaterialien aus Siliciumoxid und a-Aluminiumoxid zeigen dasselbe Verhalten wie Materialien aus Siliciumoxid, weisen jedoch eine geringere Kapazität auf. Die Materialen wurden hinsichtlich ihres Einsatzes in chromatographischen Verfahren und Batch-Prozessen untersucht und ein Prozessentwurf für einen zweistufigen Batch-Prozess im Rührkessel erarbeitet. KW - Molkeproteine KW - Adsorption Y1 - 2012 U6 - https://doi.org/10.1002/cite.201250395 SN - 0009-286X SN - 1522-2640 (eISSN) N1 - ProcessNet-Jahrestagung 2012 und 30. DECHEMA-Jahrestagung der Biotechnologen, 10. – 13. September 2012, Karlsruhe VL - 84 IS - 8 SP - 1285 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Atlas, Glen A1 - Brealey, David A1 - Dhar, Sunil A1 - Dikta, Gerhard A1 - Singer, Meryvn T1 - Additional hemodynamic measurements with an esophageal Doppler monitor: a preliminary report of compliance, force, kinetic energy, and afterload in the clinical setting JF - Journal of clinical monitoring and computing N2 - The esophageal Doppler monitor (EDM) is a minimally-invasive hemodynamic device which evaluates both cardiac output (CO), and fluid status, by estimating stroke volume (SV) and calculating heart rate (HR). The measurement of these parameters is based upon a continuous and accurate approximation of distal thoracic aortic blood flow. Furthermore, the peak velocity (PV) and mean acceleration (MA), of aortic blood flow at this anatomic location, are also determined by the EDM. The purpose of this preliminary report is to examine additional clinical hemodynamic calculations of: compliance (C), kinetic energy (KE), force (F), and afterload (TSVRi). These data were derived using both velocity-based measurements, provided by the EDM, as well as other contemporaneous physiologic parameters. Data were obtained from anesthetized patients undergoing surgery or who were in a critical care unit. A graphical inspection of these measurements is presented and discussed with respect to each patient’s clinical situation. When normalized to each of their initial values, F and KE both consistently demonstrated more discriminative power than either PV or MA. The EDM offers additional applications for hemodynamic monitoring. Further research regarding the accuracy, utility, and limitations of these parameters is therefore indicated. KW - Acceleration KW - Velocity KW - Kinetic energy KW - Force KW - Compliance KW - Afterload KW - Contractility KW - Volume status KW - Esophageal Doppler monitor Y1 - 2012 SN - 1573-2614 U6 - https://doi.org/10.1007/s10877-012-9386-5 IS - 26 SP - 473 EP - 482 PB - Springer Nature CY - London ER -