TY - CHAP A1 - Heuermann, Holger A1 - Sadeghfam, Arash T1 - Analog Amplitude-Locked Loop Circuit to Support RF Energy Solutions T2 - IEEE MTT-S International Microwave Symposium Digest Y1 - 2016 SN - 978-150900698-4 U6 - https://doi.org/10.1109/MWSYM.2016.7540092 ER - TY - CHAP A1 - Alhwarin, Faraj A1 - Schiffer, Stefan A1 - Ferrein, Alexander A1 - Scholl, Ingrid T1 - An Optimized Method for 3D Body Scanning Applications Based on KinectFusion T2 - Communications in Computer and Information Science Y1 - 2019 U6 - https://doi.org/10.1007/978-3-030-29196-9_6 SN - 1865-0929 N1 - 11th International Joint Conference on Biomedical Engineering Systems and Technologies, BIOSTEC 2018; Funchal; Portugal; 19 January 2018 through 21 January 2018 VL - 1024 SP - 100 EP - 113 PB - Springer ER - TY - JOUR A1 - Hartung, Frank A1 - Kumwilaisak, W. T1 - An intraframe error concealment: nonlinear pattern alignment and directional interpolation / Kumwilaisak, W. ; Hartung, F. JF - Conference on Image Processing, 2004. ICIP '04. 2004 International / Vol. 2 . Y1 - 2004 N1 - http://dx.doi.org/10.1109/ICIP.2004.1419426 SP - 825 EP - 828 ER - TY - CHAP A1 - Zug, Sebastian A1 - Niemueller, Tim A1 - Hochgeschwender, Nico A1 - Seidensticker, Kai A1 - Seidel, Martin A1 - Friedrich, Tim A1 - Neumann, Tobias A1 - Karras, Ulrich A1 - Kraetzschmar, Gerhard K. A1 - Ferrein, Alexander T1 - An Integration Challenge to Bridge the Gap Among Industry-Inspired RoboCup Leagues T2 - RoboCup 2016: Robot World Cup XX. RoboCup 2016. Y1 - 2017 SN - 978-3-319-68792-6 U6 - https://doi.org/10.1007/978-3-319-68792-6_13 N1 - Lecture Notes in Computer Science, LNCS, Vol 9776 SP - 157 EP - 168 PB - Springer CY - Cham ER - TY - JOUR A1 - Zastrow, Udo A1 - Panagiotopoulos, P. D. T1 - An integral "Equation" approach to the unilateral contact problem JF - ZAMM - Zeitschrift für angewandte Mathematik und Mechanik. 59 (1979), H. 8 Y1 - 1979 SN - 1521-4001 SP - 392 EP - 393 ER - TY - JOUR A1 - Kowalewski, Paul A1 - Bragard, Michael A1 - Hüning, Felix A1 - De Doncker, Rik W. T1 - An inexpensive Wiegand-sensor-based rotary encoder without rotating magnets for use in electrical drives JF - IEEE Transactions on Instrumentation and Measurement N2 - This paper introduces an inexpensive Wiegand-sensor-based rotary encoder that avoids rotating magnets and is suitable for electrical-drive applications. So far, Wiegand-sensor-based encoders usually include a magnetic pole wheel with rotating permanent magnets. These encoders combine the disadvantages of an increased magnet demand and a limited maximal speed due to the centripetal force acting on the rotating magnets. The proposed approach reduces the total demand of permanent magnets drastically. Moreover, the rotating part is manufacturable from a single piece of steel, which makes it very robust and cheap. This work presents the theoretical operating principle of the proposed approach and validates its benefits on a hardware prototype. The presented proof-of-concept prototype achieves a mechanical resolution of 4.5 ° by using only 4 permanent magnets, 2Wiegand sensors and a rotating steel gear wheel with 20 teeth. KW - Rotary encoder KW - Wiegand sensor Y1 - 2023 U6 - https://doi.org/10.1109/TIM.2023.3326166 SN - 0018-9456 (Print) SN - 1557-9662 (Online) VL - 72 SP - 10 Seiten PB - IEEE CY - New York ER - TY - JOUR A1 - Faßbender, Heinz A1 - Vogler, Heiko T1 - An implementation of syntax directed functional programming on nested-stack machines JF - Formal Aspects of Computing. 4 (1992), H. 4 Y1 - 1992 SN - 0934-5043 SP - 341 EP - 375 ER - TY - CHAP A1 - Schuba, Marko A1 - Höfken, Hans-Wilhelm A1 - Linzbach, Sophie T1 - An ICS Honeynet for Detecting and Analyzing Cyberattacks in Industrial Plants T2 - 2021 International Conference on Electrical, Computer and Energy Technologies (ICECET) N2 - Cybersecurity of Industrial Control Systems (ICS) is an important issue, as ICS incidents may have a direct impact on safety of people or the environment. At the same time the awareness and knowledge about cybersecurity, particularly in the context of ICS, is alarmingly low. Industrial honeypots offer a cheap and easy to implement way to raise cybersecurity awareness and to educate ICS staff about typical attack patterns. When integrated in a productive network, industrial honeypots may not only reveal attackers early but may also distract them from the actual important systems of the network. Implementing multiple honeypots as a honeynet, the systems can be used to emulate or simulate a whole Industrial Control System. This paper describes a network of honeypots emulating HTTP, SNMP, S7communication and the Modbus protocol using Conpot, IMUNES and SNAP7. The nodes mimic SIMATIC S7 programmable logic controllers (PLCs) which are widely used across the globe. The deployed honeypots' features will be compared with the features of real SIMATIC S7 PLCs. Furthermore, the honeynet has been made publicly available for ten days and occurring cyberattacks have been analyzed KW - Conpot KW - honeypot KW - honeynet KW - ICS KW - cybersecurity Y1 - 2022 SN - 978-1-6654-4231-2 SN - 978-1-6654-4232-9 U6 - https://doi.org/10.1109/ICECET52533.2021.9698746 N1 - 2021 International Conference on Electrical, Computer and Energy Technologies (ICECET). 09-10 December 2021. Cape Town, South Africa. PB - IEEE ER - TY - JOUR A1 - Faßbender, Heinz A1 - Bühler, Gerhard T1 - An experimental command and control information system based on Enterprise Java bean technology JF - Proceedings of the 7th International Command and Control Research and Technology Symposium, September 2002, Quebec City, Kanada Y1 - 2002 SP - 1 EP - 8 ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Dammann, Philipp A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T JF - Medical Physics N2 - Purpose: MRI plays a leading diagnostic role in assessing the musculoskeletal (MSK) system and is well established for most questions at clinically used field strengths (up to 3 T). However, there are still limitations in imaging early stages of cartilage degeneration, very fine tendons and ligaments, or in locating nerve lesions, for example. 7 T MRI of the knee has already received increasing attention in the current published literature, but there is a strong need to develop new radiofrequency (RF) coils to assess more regions of the MSK system. In this work, an eight-channel transmit/receive RF array was built as a multipurpose coil for imaging some of the thus far neglected regions. An extensive coil characterization protocol and first in vivo results of the human wrist, shoulder, elbow, knee, and ankle imaged at 7 T will be presented. Methods: Eight surface loop coils with a dimension ofurn:x-wiley:00942405:media:mp7176:mp7176-math-0001 were machined from FR4 circuit board material. To facilitate easy positioning, two coil clusters, each with four loop elements, were combined to one RF transmit/receive array. An overlapped and shifted arrangement of the coil elements was chosen to reduce the mutual inductance between neighboring coils. A phantom made of body-simulating liquid was used for tuning and matching on the bench. Afterward, the S-parameters were verified on a human wrist, elbow, and shoulder. For safety validation, a detailed compliance test was performed including full wave simulations of the RF field distribution and the corresponding specific absorption rate (SAR) for all joints. In vivo images of four volunteers were assessed with gradient echo and spin echo sequences modified to obtain optimal image contrast, full anatomic coverage, and the highest spatial resolution within a reasonable acquisition time. The performance of the RF coil was additionally evaluated by in vivo B1 mapping. Results: A comparison of B1 per unit power, flip angle distribution, and anatomic images showed a fairly homogeneous excitation for the smaller joints (elbow, wrist, and ankle), while for the larger joints, the shoulder and especially the knee, B1 inhomogeneities and limited penetration depth were more pronounced. However, the greater part of the shoulder joint could be imaged.In vivo images rendered very fine anatomic details such as fascicles of the median nerve and the branching of the nerve bundles. High-resolution images of cartilage, labrum, and tendons could be acquired. Additionally, turbo spin echo (TSE) and inversion recovery sequences performed very well. Conclusions: This study demonstrates that the concept of two four-channel transmit/receive RF arrays can be used as a multipurpose coil for high-resolutionin vivo MR imaging of the musculoskeletal system at 7 T. Not only gradient echo but also typical clinical and SAR-intensive sequences such as STIR and TSE performed well. Imaging of small structures and peripheral nerves could in particular benefit from this technique. Y1 - 2010 U6 - https://doi.org/10.1118/1.3517176 SN - 2473-4209 VL - 37 IS - 12 SP - 6368 EP - 6376 PB - Wiley CY - Hoboken, NJ ER -