TY - JOUR A1 - Bank, Bart L. van de A1 - Orzada, Stephan A1 - Smits, Frits A1 - Lagemaat, Miriam W. A1 - Rodgers, Christopher T. A1 - Bitz, Andreas A1 - Scheenen, Tom W. J. T1 - Optimized (31) P MRS in the human brain at 7 T with a dedicated RF coil setup JF - NMR in Biomedicine Y1 - 2015 U6 - http://dx.doi.org/10.1002/nbm.3422 SN - 1099-1492 VL - 28 IS - 11 SP - 1570 EP - 1578 PB - Wiley CY - Weinheim ER - TY - CHAP A1 - Müller, Tim M. A1 - Altherr, Lena A1 - Leise, Philipp A1 - Pelz, Peter F. T1 - Optimization of pumping systems for buildings: Experimental validation of different degrees of model detail on a modular test rig T2 - Operations Research Proceedings 2019 N2 - Successful optimization requires an appropriate model of the system under consideration. When selecting a suitable level of detail, one has to consider solution quality as well as the computational and implementation effort. In this paper, we present a MINLP for a pumping system for the drinking water supply of high-rise buildings. We investigate the influence of the granularity of the underlying physical models on the solution quality. Therefore, we model the system with a varying level of detail regarding the friction losses, and conduct an experimental validation of our model on a modular test rig. Furthermore, we investigate the computational effort and show that it can be reduced by the integration of domain-specific knowledge. KW - Experimental validation KW - MINLP KW - Engineering optimization KW - Water supply system KW - Network design Y1 - 2020 SN - 978-3-030-48438-5 U6 - http://dx.doi.org/10.1007/978-3-030-48439-2_58 N1 - Annual International Conference of the German Operations Research Society (GOR), Dresden, Germany, September 4-6, 2019 SP - 481 EP - 488 PB - Springer CY - Cham ER - TY - JOUR A1 - Müller, Tim M. A1 - Leise, Philipp A1 - Lorenz, Imke-Sophie A1 - Altherr, Lena A1 - Pelz, Peter F. T1 - Optimization and validation of pumping system design and operation for water supply in high-rise buildings JF - Optimization and Engineering N2 - The application of mathematical optimization methods for water supply system design and operation provides the capacity to increase the energy efficiency and to lower the investment costs considerably. We present a system approach for the optimal design and operation of pumping systems in real-world high-rise buildings that is based on the usage of mixed-integer nonlinear and mixed-integer linear modeling approaches. In addition, we consider different booster station topologies, i.e. parallel and series-parallel central booster stations as well as decentral booster stations. To confirm the validity of the underlying optimization models with real-world system behavior, we additionally present validation results based on experiments conducted on a modularly constructed pumping test rig. Within the models we consider layout and control decisions for different load scenarios, leading to a Deterministic Equivalent of a two-stage stochastic optimization program. We use a piecewise linearization as well as a piecewise relaxation of the pumps’ characteristics to derive mixed-integer linear models. Besides the solution with off-the-shelf solvers, we present a problem specific exact solving algorithm to improve the computation time. Focusing on the efficient exploration of the solution space, we divide the problem into smaller subproblems, which partly can be cut off in the solution process. Furthermore, we discuss the performance and applicability of the solution approaches for real buildings and analyze the technical aspects of the solutions from an engineer’s point of view, keeping in mind the economically important trade-off between investment and operation costs. KW - Technical Operations Research KW - MINLP KW - MILP KW - Experimental validation KW - Pumping systems Y1 - 2020 U6 - http://dx.doi.org/10.1007/s11081-020-09553-4 SN - 1573-2924 VL - 2021 IS - 22 SP - 643 EP - 686 PB - Springer ER - TY - CHAP A1 - Altherr, Lena A1 - Leise, Philipp A1 - Pfetsch, Marc E. A1 - Schmitt, Andreas T1 - Optimal design of resilient technical systems on the example of water supply systems T2 - Mastering Uncertainty in Mechanical Engineering Y1 - 2021 SN - 978-3-030-78356-3 N1 - Unterkapitel des Kapitels "Strategies for Mastering Uncertainty" SP - 429 EP - 433 PB - Springer CY - Cham ER - TY - JOUR A1 - Sun, Hui A1 - Altherr, Lena A1 - Pei, Ji A1 - Pelz, Peter F. A1 - Yuan, Shouqi T1 - Optimal booster station design and operation under uncertain load JF - Applied Mechanics and Materials N2 - Given industrial applications, the costs for the operation and maintenance of a pump system typically far exceed its purchase price. For finding an optimal pump configuration which minimizes not only investment, but life-cycle costs, methods like Technical Operations Research which is based on Mixed-Integer Programming can be applied. However, during the planning phase, the designer is often faced with uncertain input data, e.g. future load demands can only be estimated. In this work, we deal with this uncertainty by developing a chance-constrained two-stage (CCTS) stochastic program. The design and operation of a booster station working under uncertain load demand are optimized to minimize total cost including purchase price, operation cost incurred by energy consumption and penalty cost resulting from water shortage. We find optimized system layouts using a sample average approximation (SAA) algorithm, and analyze the results for different risk levels of water shortage. By adjusting the risk level, the costs and performance range of the system can be balanced, and thus the system’s resilience can be engineered KW - Stochastic Programming KW - Chance Constraint KW - Engineering Application KW - Pump System KW - Water Distribution Y1 - 2018 U6 - http://dx.doi.org/10.4028/www.scientific.net/AMM.885.102 SN - 1662-7482 VL - 885 SP - 102 EP - 115 PB - Trans Tech Publications CY - Bäch ER - TY - JOUR A1 - Hagemann, Hans-Jürgen A1 - Ungelenk, J. A1 - Wiechert, D. U. T1 - Optical time domain reflectometry (OTDR) of diameter modulations in single-mode fibers. Hagemann, H. J.; Ungelenk, J.; Wiechert, D. U. JF - Journal of Lightwave Technology (J-LT) / Institute of Electrical and Electronics Engineers (IEEE). 8 (1990), H. 11 Y1 - 1990 SN - 0733-8724 SP - 1641 EP - 1645 ER - TY - CHAP A1 - Ringbeck, Thorsten A1 - Schwarte, Rudolf A1 - Buxbaum, Bernd A1 - Hess, Rudolf ED - Tang, Suning T1 - Optical GMSK modem for infrared wireless communication based on a new receiver principle in CMOS technology T2 - Optoelectronic interconnects VIII : 25 - 26 January 2001, San Jose, USA. - (Proceedings of SPIE ; 4292) Y1 - 2001 SN - 0-8194-3970-3 SN - 0038-7355 SN - 0361-0748 SN - 0277-786X N1 - Optoelectronic Interconnects <8, 2001, San Jose, Calif.> SP - 25 EP - 34 PB - SPIE CY - Bellingham, Wash. ER - TY - JOUR A1 - Hagemann, Hans-Jürgen A1 - Gudat, W. A1 - Kunz, C. T1 - Optical constants from the far infrared to the X-ray region: Mg, Al, Cu, Ag, Au, Bi, C, and Al₂O₃ JF - Journal of the Optical Society of America (JOSA) Y1 - 1975 SN - 0030-3941 U6 - http://dx.doi.org/10.1364/JOSA.65.000742 VL - 65 IS - 6 SP - 742 EP - 744 PB - Optical Society of America CY - New York ER - TY - JOUR A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Schäfer, Lena C. A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Maderwald, Stefan T1 - Open design eight-channel transmit/receive coil for high-resolution and real-time ankle imaging at 7 T JF - Medical Physics N2 - Purpose: At 1.5 T, real-time MRI of joint movement has been shown to be feasible. However, 7 T, provides higher SNR and thus an improved potential for parallel imaging acceleration. The purpose of this work was to build an open, U-shaped eight-channel transmit/receive microstrip coil for 7 T MRI to enable high-resolution and real-time imaging of the moving ankle joint. Methods: A U-shaped eight-channel transmit/receive array for the human ankle was built.urn:x-wiley:00942405:mp3399:equation:mp3399-math-0001-parameters and urn:x-wiley:00942405:mp3399:equation:mp3399-math-0002-factor were measured. SAR calculations of different ankle postures were performed to ensure patient safety. Inhomogeneities in the transmit field consequent to the open design were compensated for by the use of static RF shimming. High-resolution and real-time imaging was performed in human volunteers. Results: The presented array showed good performance with regard to patient comfort and image quality. High acceleration factors of up to 4 are feasible without visible acceleration artifacts. Reasonable image homogeneity was achieved with RF shimming. Conclusions: Open, noncylindrical designs for transmit/receive coils are practical at 7 T and real-time imaging of the moving joint is feasible with the presented coil design. Y1 - 2011 U6 - http://dx.doi.org/10.1118/1.3553399 SN - 2473-4209 VL - 38 IS - 3 SP - 1162 EP - 1167 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Ferrein, Alexander A1 - Fritz, Christian A1 - Lakemeyer, Gerhard T1 - On-Line Decision-Theoretic Golog for Unpredictable Domains / Ferrein, Alexander ; Fritz, Christian ; Lakemeyer, Gerhard JF - KI 2004: Advances in Artificial Intelligence : 27th Annual German Conference on AI, KI 2004, Ulm, Germany, September 20-24, 2004. Proceedings Y1 - 2004 N1 - Lecture Notes in Computer Science ; 3238 SP - 322 EP - 336 PB - Springer CY - Berlin ER -