TY - CHAP A1 - Milkova, Kristina A1 - Butenweg, Christoph A1 - Dumova-Jovanoska, Elena T1 - Region-sensitive comprehensive procedure for determination of seismic fragility curves T2 - 1st Croatian Conference on Earthquake Engineering 1CroCEE 22-24 March 2021 Zagreb, Croatia N2 - Seismic vulnerability estimation of existing structures is unquestionably interesting topic of high priority, particularly after earthquake events. Having in mind the vast number of old masonry buildings in North Macedonia serving as public institutions, it is evident that the structural assessment of these buildings is an issue of great importance. In this paper, a comprehensive methodology for the development of seismic fragility curves of existing masonry buildings is presented. A scenario – based method that incorporates the knowledge of the tectonic style of the considered region, the active fault characterization, the earth crust model and the historical seismicity (determined via the Neo Deterministic approach) is used for calculation of the necessary response spectra. The capacity of the investigated masonry buildings has been determined by using nonlinear static analysis. MINEA software (SDA Engineering) is used for verification of the structural safety of the structures Performance point, obtained from the intersection of the capacity of the building and the spectra used, is selected as a response parameter. The thresholds of the spectral displacement are obtained by splitting the capacity curve into five parts, utilizing empirical formulas which are represented as a function of yield displacement and ultimate displacement. As a result, four levels of damage limit states are determined. A maximum likelihood estimation procedure for the process of fragility curves determination is noted as a final step in the proposed procedure. As a result, region specific series of vulnerability curves for structures are defined. KW - seismic risk KW - seismic vulnerability KW - fragility curves KW - masonry structures Y1 - 2021 U6 - http://dx.doi.org/10.5592/CO/1CroCEE.2021.158 SP - 121 EP - 128 PB - University of Zagreb CY - Zagreb ER - TY - CHAP A1 - Pauksztat, Anja A1 - Kuperjans, Isabel A1 - de Hesselle, M. T1 - Referenzformeln für Energiebedarf und CO2-Emissionen in der Glasindustrie T2 - Energieeffizienz - Chancen für die Zukunft : Tagung Berlin, 14. und 15. November 2006. - (VDI-Berichte ; 1951) Y1 - 2006 SN - 3-18-091951-5 SP - 179 EP - 190 PB - VDI-Verl. CY - Düsseldorf ET - Nichtred. Ms.-Dr. ER - TY - CHAP A1 - Kuperjans, Isabel A1 - Seitz, C.-W. A1 - Wilhelm, H.-G. T1 - Realisierung einer Fernwärmeversorgung mit Kraft-Wärme-Kopplung für den Wohnwertpark Brühl T2 - Energiemanagement in Kommunen und öffentlichen Einrichtungen : Tagung Stuttgart, 16. und 17. September 1998. - (VDI-Berichte ; 1424) Y1 - 1998 SN - 3-18-091424-6 SP - 129 EP - 138 PB - VDI-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Losch, S. A1 - Butenweg, Christoph T1 - Qualitätsgesteuerte Bemessung von Stahlbetontragwerken mit der FE-Methode T2 - 11. Forum Bauinformatik Darmstadt '99 : [Beiträge der Forumsteilnehmer, die im Rahmen des 11. Forums Bauinformatik vom 22. bis 24. September 1999 in Darmstadt ihre Forschung präsentiert ...] / Tobias Kuhn ... (Hrsg.) (Fortschritt-Berichte VDI : Reihe 4 Bauingenieurwesen ; Nr. 156) Y1 - 1999 SN - 3-18-315604-0 SP - 208 EP - 215 PB - VDI-Verlag CY - Düsseldorf ER - TY - CHAP A1 - Hellmanns, Mark A1 - Hartung, I. A1 - Dilger, Klaus A1 - Böhm, Stefan T1 - Quality assurance of manual guided joining and welding devices T2 - Proceedings of the IIW International Conference on Advances in Welding and Allied Technologies : July 16 - 17, 2009, Singapore Y1 - 2009 SN - 9789810832605 SP - 219 EP - 222 PB - International Institute of Welding CY - Roissy ER - TY - CHAP A1 - Sirazitdinova, Y. A1 - Dulzon, A. A1 - Müller, Burghard T1 - Project management practices in engineering university T2 - 21st International Conference for Students and Young Scientists: Modern Technique and Technologies, MTT 2015; National Research Tomsk Polytechnic UniversityTomsk; Russian Federation; 5 October 2015 through 9 October 2015 Y1 - 2015 U6 - http://dx.doi.org/10.1088/1757-899X/93/1/012080 N1 - IOP Conference Series: Materials Science and Engineering Vol. 93, Issue 1 ER - TY - CHAP A1 - Hellmanns, Mark A1 - Böhm, Stefan A1 - Dilger, Klaus T1 - Progress of the manual application of adhesives T2 - Proceedings of the 3rd World Congress on Adhesion and Related Phenomena : WCARP-III, October 15 -18, 2006, Beijing, China Y1 - 2006 SP - 275 EP - 277 PB - Beijing Adhesion Society of China CY - Beijing ER - TY - CHAP A1 - Dören, Horst-Peter A1 - Molitor, M. A1 - Ertl, Karl-Heinz ED - Lugscheider, Erich T1 - Problematik der Härtemessung an pulverflammgespritzten Verschleißschutzschichten mit Hilfe mobiler, dynamischer Härteprüfverfahren T2 - Thermische Spritzkonferenz : TS 96 ; Vorträge und Posterbeiträge. Essen 6. bis 8. März 1996. DVS-Berichte. Bd. 175 Y1 - 1996 SN - 3-87155-480-4 SP - 249 EP - 254 PB - DVS-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Kern, Alexander A1 - Dikta, Gerhard T1 - Probability of damage of electrical and electronic systems due to indirect lightning flashes - investigation of data from German insurance companies N2 - In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not. KW - Blitzschutz KW - lightning flash Y1 - 2009 ER - TY - CHAP A1 - Kumaran, P. A1 - Gopinathan, M. A1 - Razali, N. M. A1 - Kuperjans, Isabel A1 - Hariffin, B. A1 - Hamdan, H. T1 - Preliminary evaluation of atomization characteristics of improved biodiesel for gas turbine application T2 - IOP Conference Series: Earth and Environmental Science (EES) Y1 - 2013 U6 - http://dx.doi.org/10.1088/1755-1315/16/1/012014 SN - 1755-1315 VL - 16 IS - 1 SP - 012014/1 EP - 012014/4 PB - Institute of Physics Publishing (IOP) CY - London [u.a.] ER -