TY - CHAP A1 - Biener, Ernst T1 - Abfallwirtschaft T2 - Wendehorst Beispiele aus der Baupraxis. - 3. Aufl. Y1 - 2009 SN - 978-3-8348-0684-0 ; 978-3-8348-9997-2 U6 - http://dx.doi.org/10.1007/978-3-8348-9997-2_16 SP - 463 EP - 499 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Dachwald, Bernd A1 - Ball, Andrew J. A1 - Ulamec, Stephan A1 - Price, Michael E. T1 - A small mission for in situ exploration of a primitive binary near-Earth asteroid / Ball, Andrew J. ; Ulamec, Stephan ; Dachwald, Bernd ; Price, Michael E. ; [u.a.] JF - Advances in Space Research. 43 (2009), H. 2 Y1 - 2009 SN - 0273-1177 SP - 317 EP - 324 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Tippkötter, Nils A1 - Stückmann, Henning A1 - Kroll, Stephen A1 - Winkelmann, Gunda A1 - Noack, Udo A1 - Scheper, Thomas A1 - Ulber, Roland T1 - A semi-quantitative dipstick assay for microcystin JF - Analytical and Bioanalytical Chemistry N2 - An immunochromatographic lateral flow dipstick assay for the fast detection of microcystin-LR was developed. Colloid gold particles with diameters of 40 nm were used as red-colored antibody labels for the visual detection of the antigen. The new dipstick sensor is capable of detecting down to 5 µg·l−1 (ppb; total inversion of the color signal) or 1 ppb (observation of color grading) of microcystin-LR. The course of the labeling reaction was observed via spectrometric wave shifts caused by the change of particle size during the binding of antibodies. Different stabilizing reagents showed that especially bovine serum albumin (BSA) and casein increase the assays sensitivity and the conjugate stability. Performance of the dipsticks was quantified by pattern processing of capture zone CCD images. Storage stability of dipsticks and conjugate suspensions over 115 days under different conditions were monitored. The ready-to-use dipsticks were successfully tested with microcystin-LR-spiked samples of outdoor drinking- and salt water and applied to the tissue of microcystin-fed mussels. Y1 - 2009 U6 - http://dx.doi.org/10.1007/s00216-009-2750-8 SN - 1618-2650 VL - 394 IS - 3 SP - 863 EP - 869 PB - springer CY - Berlin ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, M. A1 - Hormes, M. A1 - Steinseifer, U. A1 - Arora, D. A1 - Coronado, O. A1 - Pasquali, M. T1 - A Review of Computational Fluid Dynamics Analysis of Blood Pumps JF - European Journal of Applied Mathematics. 20 (2009), H. 4 Y1 - 2009 SP - 363 EP - 397 PB - Cambridge Univ. Press CY - Cambridge ER - TY - CHAP A1 - Matcha, Heike A1 - Quasten, Gero T1 - A Parametric-Typological Tool: More Diversity for Mass Produced Single Family Homes Through Parametrized Design and Customized Mass Production T2 - Computation: The New Realm of Architectural Design [27th eCAADe Conference Proceedings Y1 - 2009 SN - 978-0-9541183-8-9 SP - 409 EP - 416 ER - TY - JOUR A1 - Arida, Hassan A1 - Turek, Monika A1 - Rolka, David A1 - Schöning, Michael Josef T1 - A Novel Thin-Film Copper Array Based on an Organic/Inorganic Sensor Hybrid: Microfabrication, Potentiometric Characterization, and Flow-Injection Analysis Application JF - Electroanalysis. 21 (2009), H. 10 Y1 - 2009 SN - 1040-0397 SP - 1145 EP - 1151 PB - Wiley CY - Weinheim ER - TY - GEN A1 - Butenweg, Christoph A1 - Gellert, Christoph A1 - Reindl, Lukas A1 - Meskouris, Konstantin T1 - A nonlinear method for the seismic safety verification of masonry buildings N2 - In order for traditional masonry to stay a competitive building material in seismically active regions there is an urgent demand for modern, deformation-based verification procedures which exploit the nonlinear load bearing reserves. The Capacity Spectrum Method (CSM) is a widely accepted design approach in the field of reinforced concrete and steel construction. It compares the seismic action with the load-bearing capacity of the building considering nonlinear material behavior with its post-peak capacity. The bearing capacity of the building is calculated iteratively using single wall capacity curves. This paper presents a new approach for the bilinear approximation of single wall capacity curves in the style of EC6/EC8 respectively FEMA 306/FEMA 356 based on recent shear wall test results of the European Collective-Research Project “ESECMaSE”. The application of the CSM to masonry structures by using bilinear approximations of capacity curves as input is demonstrated on the example of a typical German residential home. Y1 - 2009 N1 - COMPDYN 2009 - 2nd International Conference on Computational Methods in Structural Dynamics & Earthquake Engineering. Isles of Rhodes, Greece, June 22-24,2009. PB - National Technical University of Athens CY - Athen ER - TY - JOUR A1 - Schwarzer, Klemens A1 - da Silva, Vieira E. A1 - Hoffschmidt, Bernhard A1 - Schwarzer, T. T1 - A new solar desalination system with heat recovery for decentralised drinking water production JF - Desalination. 248 (2009), H. 1-3 Y1 - 2009 SN - 0011-9164 N1 - Water and Sanitation in International Development and Disaster Relief (WSIDDR) International Workshop Edinburgh, Scotland, UK, 28–30 May 2008 SP - 204 EP - 211 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Meskouris, Konstantin A1 - Holler, Stefan A1 - Butenweg, Christoph A1 - Meiners, Daniel T1 - A multiphase model with hypoplastic formulation of the solid phase and its application to earthquake engineering problems T2 - Computational structural dynamics and earthquake engineering / ed. by Manolis Papadrakakis .... (Structures and infrastructures series ; 2) Y1 - 2009 SN - 978-0-415-45261-8 U6 - http://dx.doi.org/10.1201/9780203881637.ch19 SP - 293 EP - 308 PB - CRC Press CY - Boca Raton, Fla. [u.a.] ER - TY - JOUR A1 - Moreno i Codinachs, L. A1 - Birkenstock, C. A1 - Garma, T. A1 - Zierold, R. A1 - Bachmann, J. A1 - Nielsch, K. A1 - Schöning, Michael Josef A1 - Fontcuberta i Morral, A. T1 - A micron-sized nanoporous multifunction sensing device JF - physica status solidi (a) . 206 (2009), H. 3 Y1 - 2009 SN - 1862-6319 N1 - Special Issue: Engineering of Functional Interfaces (EnFI 08) SP - 435 EP - 441 PB - Wiley CY - Weinheim ER -