TY - CHAP A1 - Rendon, Carlos A1 - Dieckmann, Simon A1 - Weidle, Mathias A1 - Dersch, Jürgen A1 - Teixeira Boura, Cristiano José A1 - Polklas, Thomas A1 - Kuschel, Marcus A1 - Herrmann, Ulf T1 - Retrofitting of existing parabolic trough collector power plants with molten salt tower systems T2 - AIP Conference Proceedings Y1 - 2018 U6 - http://dx.doi.org/10.1063/1.5067030 VL - 2033 IS - 1 SP - 030014-1 EP - 030014-8 ER - TY - JOUR A1 - Puppe, Michael A1 - Giuliano, Stefano A1 - Frantz, Cathy A1 - Uhlig, Ralf A1 - Schumacher, Ralph A1 - Ibraheem, Wagdi A1 - Schmalz, Stefan A1 - Waldmann, Barbara A1 - Guder, Christoph A1 - Peter, Dennis A1 - Schwager, Christian A1 - Teixeira Boura, Cristiano José A1 - Alexopoulos, Spiros A1 - Spiegel, Michael A1 - Wortmann, Jürgen A1 - Hinrichs, Matthias A1 - Engelhard, Manfred A1 - Aust, Michael T1 - Techno-economic optimization of molten salt solar tower plants JF - AIP Conference Proceedings art.no. 040033 N2 - In this paper the results of a techno-economic analysis of improved and optimized molten salt solar tower plants (MSSTP plants) are presented. The potential improvements that were analyzed include different receiver designs, different designs of the HTF-system and plant control, increased molten salt temperatures (up to 640°C) and multi-tower systems. Detailed technological and economic models of the solar field, solar receiver and high temperature fluid system (HTF-system) were developed and used to find potential improvements compared to a reference plant based on Solar Two technology and up-to-date cost estimations. The annual yield model calculates the annual outputs and the LCOE of all variants. An improved external tubular receiver and improved HTF-system achieves a significant decrease of LCOE compared to the reference. This is caused by lower receiver cost as well as improvements of the HTF-system and plant operation strategy, significantly reducing the plant own consumption. A novel star receiver shows potential for further cost decrease. The cavity receiver concepts result in higher LCOE due to their high investment cost, despite achieving higher efficiencies. Increased molten salt temperatures seem possible with an adapted, closed loop HTF-system and achieve comparable results to the original improved system (with 565°C) under the given boundary conditions. In this analysis all multi tower systems show lower economic viability compared to single tower systems, caused by high additional cost for piping connections and higher cost of the receivers. REFERENCES Y1 - 2019 U6 - http://dx.doi.org/10.1063/1.5067069 VL - 2033 IS - Issue 1 PB - AIP Publishing CY - Melville, NY ER - TY - CHAP A1 - Gorzalka, Philip A1 - Dahlke, Dennis A1 - Göttsche, Joachim A1 - Israel, Martin A1 - Patel, Dhruvkumar A1 - Prahl, Christoph A1 - Schmiedt, Jacob Estevam A1 - Frommholz, Dirk A1 - Hoffschmidt, Bernhard A1 - Linkiewicz, Magdalena T1 - Building Tomograph–From Remote Sensing Data of Existing Buildings to Building Energy Simulation Input T2 - EBC, Annex 71, Fifth expert meeting, October 17-19, 2018, Innsbruck, Austria Y1 - 2018 ER - TY - CHAP A1 - Blanke, Tobias A1 - Dring, Bernd A1 - Vontein, Marius A1 - Kuhnhenne, Markus T1 - Climate Change Mitigation Potentials of Vertical Building Integrated Photovoltaic T2 - 8th International Workshop on Integration of Solar Power into Power Systems : 16-17 October 2018, Stockholm, Sweden Y1 - 2018 SP - 1 EP - 7 ER - TY - CHAP A1 - Breitbach, Gerd A1 - Alexopoulos, Spiros A1 - May, Martin A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Analysis of volumetric solar radiation absorbers made of wire meshes T2 - AIP Conference Proceedings Y1 - 2019 U6 - http://dx.doi.org/10.1063/1.5117521 SN - 0094243X VL - 2126 SP - 030009-1 EP - 030009-6 ER - TY - CHAP A1 - Mahdi, Zahra A1 - Rendón, Carlos A1 - Schwager, Christian A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Novel concept for indirect solar-heated methane reforming T2 - AIP Conference Proceedings Y1 - 2019 U6 - http://dx.doi.org/10.1063/1.5117694 SN - 0094-243X VL - 2126 SP - 180014-1 EP - 180014-7 PB - AIP Publishing CY - Melville, NY ER - TY - CHAP A1 - May, Martin A1 - Breitbach, Gerd A1 - Alexopoulos, Spiros A1 - Latzke, Markus A1 - Bäumer, Klaus A1 - Uhlig, Ralf A1 - Söhn, Matthias A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Experimental facility for investigations of wire mesh absorbers for pressurized gases T2 - AIP Conference Proceedings Y1 - 2019 U6 - http://dx.doi.org/10.1063/1.5117547 SN - 0094243X VL - 2126 SP - 030035-1 EP - 030035-9 ER - TY - CHAP A1 - Sattler, Johannes, Christoph A1 - Alexopoulos, Spiros A1 - Caminos, Ricardo Alexander Chico A1 - Mitchell, John C. A1 - Ruiz, Victor C. A1 - Kalogirou, Soteris A1 - Ktistis, Panayiotis K. A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Dynamic simulation model of a parabolic trough collector system with concrete thermal energy storage for process steam generation T2 - AIP Conference Proceedings Y1 - 2019 U6 - http://dx.doi.org/10.1063/1.5117663 SN - 0094243X VL - 2126 SP - 150007-1 EP - 150007-8 ER - TY - CHAP A1 - Schwager, Christian A1 - Teixeira Boura, Cristiano José A1 - Flesch, Robert A1 - Alexopoulos, Spiros A1 - Herrmann, Ulf T1 - Improved efficiency prediction of a molten salt receiver based on dynamic cloud passage simulation T2 - AIP Conference Proceedings Y1 - 2019 SN - 978-0-7354-1866-0 U6 - http://dx.doi.org/10.1063/1.5117566 VL - 2126 IS - 1 SP - 030054-1 EP - 030054-8 ER - TY - JOUR A1 - Göttsche, Joachim A1 - Alexopoulos, Spiros A1 - Dümmler, Andreas A1 - Maddineni, S. K. T1 - Multi-Mirror Array Calculations With Optical Error N2 - The optical performance of a 2-axis solar concentrator was simulated with the COMSOL Multiphysics® software. The concentrator consists of a mirror array, which was created using the application builder. The mirror facets are preconfigured to form a focal point. During tracking all mirrors are moved simultaneously in a coupled mode by 2 motors in two axes, in order to keep the system in focus with the moving sun. Optical errors on each reflecting surface were implemented in combination with the solar angular cone of ± 4.65 mrad. As a result, the intercept factor of solar radiation that is available to the receiver was calculated as a function of the transversal and longitudinal angles of incidence. In addition, the intensity distribution on the receiver plane was calculated as a function of the incidence angles. KW - solar process heat KW - concentrating collector KW - raytracing KW - point-focussing system Y1 - 2019 SP - 1 EP - 6 ER -