TY - JOUR A1 - Weber, Tobias A1 - Englhard, Markus A1 - Arent, Jan-Christoph A1 - Hausmann, Joachim T1 - An experimental characterization of wrinkling generated during prepreg autoclave manufacturing using caul plates JF - Journal of Composite Materials Y1 - 2019 U6 - https://doi.org/10.1177/0021998319846556 SN - 1530-793X VL - 53 IS - 26-27 SP - 3757 EP - 3773 ER - TY - JOUR A1 - Hailer, Benjamin A1 - Weber, Tobias A1 - Neveling, Sebastian A1 - Dera, Samuel A1 - Arent, Jan-Christoph A1 - Middendorf, Peter T1 - Development of a test device to determine the frictional behavior between honeycomb and prepreg layers under realistic manufacturing conditions JF - Journal of Sandwich Structures & Materials N2 - In the friction tests between honeycomb with film adhesive and prepreg, the relative displacement occurs between the film adhesive and the prepreg. The film adhesive does not shift relative to the honeycomb. This is consistent with the core crush behavior where the honeycomb moves together with the film adhesive, as can be seen in Figure 2(a). The pull-through forces of the friction measurements between honeycomb and prepreg at 1 mm deformation are plotted in Figure 17(a). While the friction at 100°C is similar to the friction at 120°C, it decreases significantly at 130°C and exhibits a minimum at 140°C. At 150°C, the friction rises again slightly and then sharply at 160°C. Since the viscosity of the M18/1 prepreg resin drops significantly before it cures [23], the minimum friction at 140°C could result from a minimum viscosity of the mixture of prepreg resin and film adhesive before the bond subsequently cures. Figure 17(b) shows the mean value curve of the friction measurements at 140°C. The error bars, which represent the standard deviation, reveal the good repeatability of the tests. The force curve is approximately horizontal between 1 mm and 2 mm. The friction then slightly rises. As with interlaminar friction measurements, this could be due to the fact that resin is removed by friction and the proportion of boundary lubrication increases. Figure 18 shows the surfaces after the friction measurement. The honeycomb cell walls are clearly visible in the film adhesive. There are areas where the film adhesive is completely removed and the carrier material of the film adhesive becomes visible. In addition, the viscosity of the resin changes as the curing progresses during the friction test. This can also affect the force-displacement curve. Y1 - 2020 U6 - https://doi.org/10.1177/1099636220923986 SN - 1530-7972 IS - Volume 23, Issue 7 SP - 3017 EP - 3043 PB - Sage CY - London ER - TY - JOUR A1 - Engeln-Müllges, Gisela T1 - Entartungsbedingungen für Gleitflächennomogramme und Nomographierbarkeitsbedingungen für Fluchtebenennomogramme JF - ZAMM ‐ Journal of Applied Mathematics and Mechanics / Zeitschrift für Angewandte Mathematik und Mechanik Y1 - 1982 U6 - https://doi.org/10.1002/zamm.19820620203 SN - 1521-4001 VL - 62 IS - 2 SP - 77 EP - 93 ER - TY - PAT A1 - Al-Kaidy, Huschyar A1 - Tippkötter, Nils A1 - Ulber, Roland T1 - Vorrichtung und Verfahren zur Bestimmung des Kontaktwinkels eines Flüssigkörpers mit einer Festkörperoberfläche N2 - Die vorliegende Erfindung betrifft eine Vorrichtung und ein Verfahren zur Bestimmung des Kontaktwinkels eines flüssigen oder mit Flüssigkeit gefüllten Körpers. Dieser besteht aus einem Träger (1) und einer damit verbundenen, in einem Winkelbereich von mehr als 0 ° bis maximal 90 ° neigbaren Ebene (8) mit einer darin ausgebildeten Abrollbahn (9) für den flüssigen oder mit Flüssigkeit gefüllten Körper. An der Ebene (8) sind mehrere Sensoren (11,12) zur Erfassung der Rolldauer des Körpers entlang der Rollstrecke angeordnet. Erfindungsgemäß ist vorgesehen, dass die Einstellung des Neigungswinkels der Ebene (8) über ein Winkelmessgerät (10) erfolgt, wodurch ein Abrollwinkel erfassbar ist, bei dem der Körper in Bewegung gerät. Aus der Rolldauer, der Rollstrecke und dem Abrollwinkel wird der Kontaktwinkel des Körpers ermittelt. Y1 - 2016 N1 - Patent auch unter DE102014000419 und WO2015107159 veröffentlicht. ER - TY - PAT A1 - Huschyar, Al-Kaidy A1 - Tippkötter, Nils A1 - Ulber, Roland T1 - System und Verfahren zur Durchführung von chemischen, biologischen oder physikalischen Reaktionen Y1 - 2015 N1 - Patent EP2821134A1 ER - TY - PAT A1 - Stadtmüller, Ralf A1 - Tippkötter, Nils A1 - Ulber, Roland T1 - Method for production of single-stranded macronucleotides N2 - The invention relates to a method for production of single-stranded macronucleotides by amplifying and ligating an extended monomeric single-stranded target nucleic acid sequence (targetss) into a repetitive cluster of double-stranded target nucleic acid sequences (targetds), and subsequently cloning the construct into a vector (aptagene vector). The aptagene vector is transformed into host cells for replication of the aptagene and isolated in order to optain single-stranded target sequences (targetss). The invention also relates to single-stranded nucleic acids, produced by a method of the invention. Y1 - 2015 N1 - Patent auch unter EP2774996, EP2774996, US2017145460 und US9944966 veröffentlicht. ER - TY - JOUR A1 - Khayyam, Hamid A1 - Jamali, Ali A1 - Bab-Hadiashar, Alireza A1 - Esch, Thomas A1 - Ramakrishna, Seeram A1 - Jalil, Mahdi A1 - Naebe, Minoo T1 - A Novel Hybrid Machine Learning Algorithm for Limited and Big Data Modelling with Application in Industry 4.0 JF - IEEE Access N2 - To meet the challenges of manufacturing smart products, the manufacturing plants have been radically changed to become smart factories underpinned by industry 4.0 technologies. The transformation is assisted by employment of machine learning techniques that can deal with modeling both big or limited data. This manuscript reviews these concepts and present a case study that demonstrates the use of a novel intelligent hybrid algorithms for Industry 4.0 applications with limited data. In particular, an intelligent algorithm is proposed for robust data modeling of nonlinear systems based on input-output data. In our approach, a novel hybrid data-driven combining the Group-Method of Data-Handling and Singular-Value Decomposition is adapted to find an offline deterministic model combined with Pareto multi-objective optimization to overcome the overfitting issue. An Unscented-Kalman-Filter is also incorporated to update the coefficient of the deterministic model and increase its robustness against data uncertainties. The effectiveness of the proposed method is examined on a set of real industrial measurements. Y1 - 2020 SN - 2169-3536 U6 - https://doi.org/10.1109/ACCESS.2020.2999898 SP - 1 EP - 12 PB - IEEE CY - New York, NY ER - TY - CHAP A1 - Wulfhorst, Helene A1 - Merseburg, Johannes A1 - Tippkötter, Nils T1 - Analyse von Lignocellulose mittels dynamischer Differenzkalorimetrie und Infrarot – Spektrometrie T2 - 12. Dresdner Sensor-Symposium 2015 2015-12-07 - 2015-12-09 Y1 - 2015 SN - 978-3-9813484-9-1 U6 - https://doi.org/10.5162/12dss2015/P6.2 SP - 210 EP - 215 ER - TY - RPRT A1 - Tippkötter, Nils A1 - Wagner, Sebastian T1 - Biomimetischer Klebstoff aus ligninhaltigen Pflanzenresten (Teilvorhaben 1 und 2) : Schlussbericht zum Vorhaben : Laufzeit: 01.01.2016 bis 31.03.2019 Y1 - 2019 U6 - https://doi.org/10.2314/KXP:169732777X N1 - Förderkennzeichen BMEL 22030514 - 22004615 PB - FH Aachen CY - Jülich ER - TY - JOUR A1 - Rausch, Valentin A1 - Harbrecht, Andreas A1 - Kahmann, Stephanie Lucina A1 - Fenten, Thomas A1 - Jovanovic, Nebojsa A1 - Hackl, Michael A1 - Müller, Lars P. A1 - Staat, Manfred A1 - Wegmann, Kilian T1 - Osteosynthesis of Phalangeal Fractures: Biomechanical Comparison of Kirschner Wires, Plates, and Compression Screws JF - The Journal of Hand Surgery N2 - Purpose The aim of this study was to compare several osteosynthesis techniques (intramedullary headless compression screws, T-plates, and Kirschner wires) for distal epiphyseal fractures of proximal phalanges in a human cadaveric model. Methods A total of 90 proximal phalanges from 30 specimens (index, ring, and middle fingers) were used for this study. After stripping off all soft tissue, a transverse distal epiphyseal fracture was simulated at the proximal phalanx. The 30 specimens were randomly assigned to 1 fixation technique (30 per technique), either a 3.0-mm intramedullary headless compression screw, locking plate fixation with a 2.0-mm T-plate, or 2 oblique 1.0-mm Kirschner wires. Displacement analysis (bending, distraction, and torsion) was performed using optical tracking of an applied random speckle pattern after osteosynthesis. Biomechanical testing was performed with increasing cyclic loading and with cyclic load to failure using a biaxial torsion-tension testing machine. Results Cannulated intramedullary compression screws showed significantly less displacement at the fracture site in torsional testing. Furthermore, screws were significantly more stable in bending testing. Kirschner wires were significantly less stable than plating or screw fixation in any cyclic load to failure test setup. Conclusions Intramedullary compression screws are a highly stable alternative in the treatment of transverse distal epiphyseal phalangeal fractures. Kirschner wires seem to be inferior regarding displacement properties and primary stability. Clinical relevance Fracture fixation of phalangeal fractures using plate osteosynthesis may have the advantage of a very rigid reduction, but disadvantages such as stiffness owing to the more invasive surgical approach and soft tissue irritation should be taken into account. Headless compression screws represent a minimally invasive choice for fixation with good biomechanical properties. Y1 - 2020 U6 - https://doi.org/10.1016/j.jhsa.2020.04.010 SN - 0363-5023 VL - 45 IS - 10 SP - 987.e1 EP - 987.e8 PB - Elsevier CY - Amsterdam ER -