TY - CHAP A1 - Balaskas, Georgios A1 - Hoffmeister, Benno A1 - Butenweg, Christoph A1 - Pilz, Marco A1 - Bauer, Anna ED - Papadrakakis, Manolis ED - Fragiadakis, Michalis T1 - Earthquake early warning and response system based on intelligent seismic and monitoring sensors embedded in a communication platform and coupled with BIM models T2 - Proceedings of COMPDYN 2021 N2 - This paper describes the concept of an innovative, interdisciplinary, user-oriented earthquake warning and rapid response system coupled with a structural health monitoring system (SHM), capable to detect structural damages in real time. The novel system is based on interconnected decentralized seismic and structural health monitoring sensors. It is developed and will be exemplarily applied on critical infrastructures in Lower Rhine Region, in particular on a road bridge and within a chemical industrial facility. A communication network is responsible to exchange information between sensors and forward warnings and status reports about infrastructures’health condition to the concerned recipients (e.g., facility operators, local authorities). Safety measures such as emergency shutdowns are activated to mitigate structural damages and damage propagation. Local monitoring systems of the infrastructures are integrated in BIM models. The visualization of sensor data and the graphic representation of the detected damages provide spatial content to sensors data and serve as a useful and effective tool for the decision-making processes after an earthquake in the region under consideration. KW - early warning and response system KW - interconnected sensor systems KW - seismic structural damage detection via SHM KW - integration SHM in BIM Y1 - 2021 SN - 978-618-85072-5-8 U6 - https://doi.org/10.7712/120121.8539.18855 SN - 2623-3347 N1 - COMPDYN 2021, 28-30 June 2021, Streamed from Athens, Greece, 8th International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering SP - 987 EP - 998 PB - National Technical University of Athens CY - Athen ER - TY - CHAP A1 - Šakić, Bogdan A1 - Milijaš, Aleksa A1 - Marinković, Marko A1 - Butenweg, Christoph A1 - Klinkel, Sven ED - Papadrakakis, Manolis ED - Fragiadakis, Michalis T1 - Influence of prior in-plane damage on the out-of-plane response of non-load bearing unreinforced masonry walls under seismic load T2 - Proceedings of COMPDYN 2021 N2 - Reinforced concrete frames with masonry infill walls are popular form of construction all over the world as well in seismic regions. While severe earthquakes can cause high level of damage of both reinforced concrete and masonry infills, earthquakes of lower to medium intensity some-times can cause significant level of damage of masonry infill walls. Especially important is the level of damage of face loaded infill masonry walls (out-of-plane direction) as out-of-plane load cannot only bring high level of damage to the wall, it can also be life-threating for the people near the wall. The response in out-of-plane direction directly depends on the prior in-plane damage, as previous investigation shown that it decreases resistance capacity of the in-fills. Behaviour of infill masonry walls with and without prior in-plane load is investigated in the experimental campaign and the results are presented in this paper. These results are later compared with analytical approaches for the out-of-plane resistance from the literature. Conclusions based on the experimental campaign on the influence of prior in-plane damage on the out-of-plane response of infill walls are compared with the conclusions from other authors who investigated the same problematic. KW - Earthquake Engineering KW - Unreinforced masonry walls KW - Out-of-plane load KW - In- plane damage KW - Out-of-plane failure Y1 - 2021 SN - 9786188507258 U6 - https://doi.org/10.7712/120121.8527.18913 SN - 2623-3347 N1 - COMPDYN 2021, 28-30 June 2021, Streamed from Athens, Greece, 8th International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering SP - 808 EP - 828 PB - National Technical University of Athens CY - Athen ER - TY - JOUR A1 - Butenweg, Christoph A1 - Bursi, Oreste S. A1 - Paolacci, Fabrizio A1 - Marinković, Marko A1 - Lanese, Igor A1 - Nardin, Chiara A1 - Quinci, Gianluca ED - Yang, J. T1 - Seismic performance of an industrial multi-storey frame structure with process equipment subjected to shake table testing JF - Engineering Structures N2 - Past earthquakes demonstrated the high vulnerability of industrial facilities equipped with complex process technologies leading to serious damage of process equipment and multiple and simultaneous release of hazardous substances. Nonetheless, current standards for seismic design of industrial facilities are considered inadequate to guarantee proper safety conditions against exceptional events entailing loss of containment and related consequences. On these premises, the SPIF project -Seismic Performance of Multi-Component Systems in Special Risk Industrial Facilities- was proposed within the framework of the European H2020 SERA funding scheme. In detail, the objective of the SPIF project is the investigation of the seismic behaviour of a representative industrial multi-storey frame structure equipped with complex process components by means of shaking table tests. Along this main vein and in a performance-based design perspective, the issues investigated in depth are the interaction between a primary moment resisting frame (MRF) steel structure and secondary process components that influence the performance of the whole system; and a proper check of floor spectra predictions. The evaluation of experimental data clearly shows a favourable performance of the MRF structure, some weaknesses of local details due to the interaction between floor crossbeams and process components and, finally, the overconservatism of current design standards w.r.t. floor spectra predictions. KW - Multi-storey KW - Frame structure KW - Earthquake KW - Tank KW - Piping Y1 - 2021 U6 - https://doi.org/10.1016/j.engstruct.2021.112681 SN - 0141-0296 VL - 243 IS - 15 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Handschuh, Nils A1 - Stollenwerk, Dominik A1 - Borchert, Jörg T1 - Operation of thermal storage power plants under high renewable grid penetration T2 - NEIS 2021: Conference on Sustainable Energy Supply and Energy Storage Systems N2 - The planned coal phase-out in Germany by 2038 will lead to the dismantling of power plants with a total capacity of approx. 30 GW. A possible further use of these assets is the conversion of the power plants to thermal storage power plants; the use of these power plants on the day-ahead market is considerably limited by their technical parameters. In this paper, the influence of the technical boundary conditions on the operating times of these storage facilities is presented. For this purpose, the storage power plants were described as an MILP problem and two price curves, one from 2015 with a relatively low renewable penetration (33 %) and one from 2020 with a high renewable energy penetration (51 %) are compared. The operating times were examined as a function of the technical parameters and the critical influencing factors were investigated. The thermal storage power plant operation duration and the energy shifted with the price curve of 2020 increases by more than 25 % compared to 2015. KW - storage optimisation KW - storage dispatch KW - thermal storage Y1 - 2021 SN - 978-3-8007-5651-3 N1 - NEIS 2021: Conference on Sustainable Energy Supply and Energy Storage Systems. 13-14 September 2021. Hamburg, Germany SP - 261 EP - 265 PB - VDE Verlag CY - Berlin ER - TY - CHAP A1 - Kern, Alexander A1 - Imani Vashiani, Anahita A1 - Timmermanns, Tobias T1 - Threat for human beings due to touch voltages and body currents caused by direct lightning strikes in case of non-isolated lightning protection systems using natural components T2 - 35th International Conference on Lightning Protection (ICLP) and XVI International Symposium on Lightning Protection (SIPDA) N2 - For typical cases of non-isolated lightning protection systems (LPS) the impulse currents are investigated which may flow through a human body directly touching a structural part of the LPS. Based on a basic LPS model with conventional down-conductors especially the cases of external and internal steel columns and metal façades are considered and compared. Numerical simulations of the line quantities voltages and currents in the time domain are performed with an equivalent circuit of the entire LPS. As a result it can be stated that by increasing the number of conventional down-conductors and external steel columns the threat for a human being can indeed be reduced, but not down to an acceptable limit. In case of internal steel columns used as natural down-conductors the threat can be reduced sufficiently, depending on the low-resistive connection of the steel columns to the lightning equipotential bonding or the earth termination system, resp. If a metal façade is used the threat for human beings touching is usually very low, if the façade is sufficiently interconnected and multiply connected to the lightning equipotential bonding or the earth termination system, resp. KW - Lightning protection system KW - down-conductor KW - steel columns KW - metal façade KW - touch voltage Y1 - 2021 SN - 978-1-6654-2346-5 U6 - https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627465 N1 - 35th International Conference on Lightning Protection (ICLP) and XVI International Symposium on Lightning Protection (SIPDA), 20-26 Sept. 2021, Colombo, Sri Lanka PB - IEEE CY - New York, NY ER - TY - BOOK A1 - Pieper, Martin T1 - Quantum mechanics: Introduction to mathematical formulation N2 - Anyone who has always wanted to understand the hieroglyphs on Sheldon's blackboard in the TV series The Big Bang Theory or who wanted to know exactly what the fate of Schrödinger's cat is all about will find a short, descriptive introduction to the world of quantum mechanics in this essential. The text particularly focuses on the mathematical description in the Hilbert space. The content goes beyond popular scientific presentations, but is nevertheless suitable for readers without special prior knowledge thanks to the clear examples. KW - Quantenmechanik KW - Hilbert Room KW - Postulates KW - Schrödingers cat KW - Operators Y1 - 2021 SN - 978-3-658-32644-9 SN - 978-3-658-32645-6 U6 - https://doi.org/10.1007/978-3-658-32645-6 PB - Springer CY - Wiesbaden ER - TY - CHAP A1 - Jordan, Frank A1 - Katz, Christiane A1 - Pieper, Martin T1 - Online-Kollaboration in der Mathematik: Ein Design-Based-Research-Projekt T2 - Forschungsimpulse für hybrides Lehren und Lernen an Hochschulen N2 - Die Studie erörtert anhand eines Fallbeispiels aus der Mathematik für Ingenieur*innen, wie didaktische Gestaltungsprinzipien für Soziale Präsenz, Kollaboration und das Lösen von praxisnahen Problemen mit mathematischem Denken in einer Online-Umgebung aussehen können. Hierfür zieht der Beitrag den forschungsmethodologischen Rahmen Design-Based Research (DBR) hinzu und berichtet über Zwischenergebnisse. DBR wird an dieser Stelle als eine systematische Herangehensweise an kurzfristige Lehrveränderungen und als Chance auf dem Weg zu einer neuen Hochschullehre nach der COVID-19-Pandemie dargestellt, die theoretische und empirische Erkenntnisse mit Praxisverknüpfung und -relevanz vereint. Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:832-cos4-9465 SP - 245 EP - 261 PB - TH Köln CY - Köln ER - TY - CHAP A1 - El Moussaoui, Noureddine A1 - Kassmi, Khalil A1 - Alexopoulos, Spiros A1 - Schwarzer, Klemens A1 - Chayeb, Hamid A1 - Bachiri, Najib T1 - Simulation studies on a new innovative design of a hybrid solar distiller MSDH alimented with a thermal and photovoltaic energy T2 - Materialstoday: Proceedings N2 - In this paper, we present the structure, the simulation the operation of a multi-stage, hybrid solar desalination system (MSDH), powered by thermal and photovoltaic (PV) (MSDH) energy. The MSDH system consists of a lower basin, eight horizontal stages, a field of four flat thermal collectors with a total area of 8.4 m2, 3 Kw PV panels and solar batteries. During the day the system is heated by thermal energy, and at night by heating resistors, powered by solar batteries. These batteries are charged by the photovoltaic panels during the day. More specifically, during the day and at night, we analyse the temperature of the stages and the production of distilled water according to the solar irradiation intensity and the electric heating power, supplied by the solar batteries. The simulations were carried out in the meteorological conditions of the winter month (February 2020), presenting intensities of irradiance and ambient temperature reaching 824 W/m2 and 23 °C respectively. The results obtained show that during the day the system is heated by the thermal collectors, the temperature of the stages and the quantity of water produced reach 80 °C and 30 Kg respectively. At night, from 6p.m. the system is heated by the electric energy stored in the batteries, the temperature of the stages and the quantity of water produced reach respectively 90 °C and 104 Kg for an electric heating power of 2 Kw. Moreover, when the electric power varies from 1 Kw to 3 Kw the quantity of water produced varies from 92 Kg to 134 Kg. The analysis of these results and their comparison with conventional solar thermal desalination systems shows a clear improvement both in the heating of the stages, by 10%, and in the quantity of water produced by a factor of 3. Y1 - 2021 U6 - https://doi.org/10.1016/j.matpr.2021.03.115 SN - 2214-7853 N1 - The Fourth edition of the International Conference on Materials & Environmental Science (ICMES 2020), virtual conference, November 18-28, 2020, Morocco VL - 45 IS - 8 SP - 7653 EP - 7660 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Butenweg, Christoph A1 - Gellert, Christoph A1 - Meyer, Udo T1 - Erdbebenbemessung bei Mauerwerksbauten T2 - Mauerwerk Kalender 2021: Kunststoffverankerungen Digitalisierung im Mauerwerksbau N2 - Der vorliegende Beitrag stellt den seismischen Nachweis von Mauerwerksbauten in Deutschland auf Grundlage der DIN EN 1998‐1/NA vor, wobei auch die wesentlichen Änderungen zu der Norm DIN 4149 vergleichend erläutert werden. Vorgestellt werden die Definition der Erdbebeneinwirkung, das seismische Verhalten von Mauerwerksbauten und die Erläuterung der Rechenverfahren. Darauf aufbauend wird die Anwendung an drei Praxisbeispielen demonstriert. Y1 - 2021 SN - 9783433032930 SN - 9783433610732 U6 - https://doi.org/10.1002/9783433610732.ch12 SP - 329 EP - 355 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Butenweg, Christoph A1 - Kubalski, Thomas A1 - El-Deib, Khaled A1 - Gellert, Christoph ED - Jesse, Dirk T1 - Erdbebennachweis von Mauerwerksbauten nach DIN EN 1998-1/NA-2021 JF - Bautechnik : Zeitschrift für den gesamten Ingenieurbau N2 - Mauerwerksbauten in Deutschland sind mit Einführung des nationalen Anwendungsdokuments DIN EN 1998-1/NA auf Grundlage einer neuen probabilistischen Erdbebenkarte nachzuweisen. Für erfolgreiche Erdbebennachweise üblicher Grundrissformen von Mauerwerksbauten stehen in dem zukünftigen Anwendungsdokument neue rechnerische Nachweismöglichkeiten zur Verfügung, mit denen die Tragfähigkeitsreserven von Mauerwerksbauten in der Baupraxis mit einem überschaubaren Aufwand besser in Ansatz gebracht werden können. Das Standardrechenverfahren ist weiterhin der kraftbasierte Nachweis, der nun mit höheren Verhaltensbeiwerten im Vergleich zur DIN 4149 durchgeführt werden kann. Die höheren Verhaltensbeiwerte basieren auf der besseren Ausnutzung der gebäudespezifischen Verformungsfähigkeit und Energiedissipation sowie der Lastumverteilung der Schubkräfte im Grundriss mit Ansatz von Rahmentragwirkung durch Wand-Deckeninteraktionen. Alternativ dazu kann ein nichtlinearer Nachweis auf Grundlage von Pushover-Analysen zur Anwendung kommen. Vervollständigt werden die Regelungen für Mauerwerksbauten durch neue Regelungen für nichttragende Innenwände und Außenmauerschalen. Der vorliegende Beitrag stellt die Grundlagen und Hintergründe der neuen rechnerischen Nachweise in DIN EN 1998-1/NA vor und demonstriert deren Anwendung an einem Beispiel aus der Praxis. Y1 - 2021 U6 - https://doi.org/10.1002/bate.202100064 SN - 1437-0999 SN - 0005-6820, 0932-8351 VL - 98 IS - 11 SP - 852 EP - 863 PB - Ernst & Sohn CY - Berlin ER -