TY - RPRT A1 - Sansom, M. A1 - Lawson, R.M. A1 - Tucho, R. A1 - Kendrick, C. A1 - Ogden, R. A1 - Resalati, S. A1 - Garay, R. A1 - Döring, Bernd A1 - Reger, V. A1 - Gilbert, J. A1 - Heikkinen, J. A1 - Hemmila, K. T1 - Building in active thermal mass into steel structures (BATIMASS) - EUR 28166EN N2 - The main objective of the BATIMASS project was to address how the energy balance in relatively lightweight steel buildings can be improved by building in ‘active thermal mass’ (ATM) into the building fabric. This was achieved through concept design, dynamic thermal modelling and testing of a number of potentially viable systems and concepts. A significant programme of thermal simulation modelling was undertaken utilising the thermally equivalent slab (TES) concept to model the passive thermal capacity effect of profiled, composite metal floor decks. It is apparent from the modelling results that thermal mass is a highly complex phenomenon which is highly dependent upon building type, occupancy patterns, climate and many other aspects of the building design and servicing strategy. The ATM systems developed, both conceptually and for prototype testing, focussed on water-cooled composite slabs, the Cofradal floor system and the phase change material (PCM) Energain. In addition to laboratory testing of prototypes, whole building monitoring was undertaken at the Kubik building in Spain and the RWTH test building in Germany. Advanced thermal modelling was also undertaken to estimate the likely benefits of the ATM concept designs developed and for comparison with the test results. In addition to thermal testing, structural tests were conducted on composite floor specimens incorporating embedded water pipes. This Final Report presents the results of the activities carried out under this RFCS contract RFSR CT 2012 00033. The work carried out is reported in six major sections corresponding to the technical Work Packages of the project. Only summaries of the work carried out are provided in this report; all work undertaken is fully reported in the formal project deliverables. KW - industrial research KW - iron and steel industry KW - research project KW - materials technology KW - resistance of materials KW - steel KW - metal structure KW - ingot KW - building industry KW - research report Y1 - 2016 SN - 978-92-79-63176-4 U6 - https://doi.org/10.2777/25999 SN - 1831-9424 PB - Publications Office of the European Union CY - Luxembourg ER - TY - JOUR A1 - Lagemaat, Miriam W. A1 - Breukels, Vincent A1 - Vos, Eline K. A1 - B., Adam A1 - Uden, Mark J. van A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Maas, Marnix C. A1 - Scheenen, Tom W. J. T1 - ¹H MR spectroscopic imaging of the prostate at 7T using spectral-spatial pulses JF - Magnetic Resonance in Medicine N2 - Purpose To assess the feasibility of prostate ¹H MR spectroscopic imaging (MRSI) using low-power spectral-spatial (SPSP) pulses at 7T, exploiting accurate spectral selection and spatial selectivity simultaneously. Methods A double spin-echo sequence was equipped with SPSP refocusing pulses with a spectral selectivity of 1 ppm. Three-dimensional prostate ¹H-MRSI at 7T was performed with the SPSP-MRSI sequence using an 8-channel transmit array coil and an endorectal receive coil in three patients with prostate cancer and in one healthy subject. No additional water or lipid suppression pulses were used. Results Prostate ¹H-MRSI could be obtained well within specific absorption rate (SAR) limits in a clinically feasible time (10 min). Next to the common citrate signals, the prostate spectra exhibited high spermine signals concealing creatine and sometimes also choline. Residual lipid signals were observed at the edges of the prostate because of limitations in spectral and spatial selectivity. Conclusion It is possible to perform prostate ¹H-MRSI at 7T with a SPSP-MRSI sequence while using separate transmit and receive coils. This low-SAR MRSI concept provides the opportunity to increase spatial resolution of MRSI within reasonable scan times. Y1 - 2016 U6 - https://doi.org/10.1002/mrm.25569 SN - 1522-2594 VL - 75 IS - 3 SP - 933 EP - 945 PB - International Society for Magnetic Resonance in Medicine ER - TY - JOUR A1 - Schmidt, K. A1 - Forkmann, K. A1 - Sinke, C. A1 - Gratz, M. A1 - Bitz, Andreas A1 - Bingel, U. T1 - The differential effect of trigeminal vs. peripheral pain stimulation on visual processing and memory encoding is influenced by pain-related fear JF - NeuroImage N2 - Compared to peripheral pain, trigeminal pain elicits higher levels of fear, which is assumed to enhance the interruptive effects of pain on concomitant cognitive processes. In this fMRI study we examined the behavioral and neural effects of trigeminal (forehead) and peripheral (hand) pain on visual processing and memory encoding. Cerebral activity was measured in 23 healthy subjects performing a visual categorization task that was immediately followed by a surprise recognition task. During the categorization task subjects received concomitant noxious electrical stimulation on the forehead or hand. Our data show that fear ratings were significantly higher for trigeminal pain. Categorization and recognition performance did not differ between pictures that were presented with trigeminal and peripheral pain. However, object categorization in the presence of trigeminal pain was associated with stronger activity in task-relevant visual areas (lateral occipital complex, LOC), memory encoding areas (hippocampus and parahippocampus) and areas implicated in emotional processing (amygdala) compared to peripheral pain. Further, individual differences in neural activation between the trigeminal and the peripheral condition were positively related to differences in fear ratings between both conditions. Functional connectivity between amygdala and LOC was increased during trigeminal compared to peripheral painful stimulation. Fear-driven compensatory resource activation seems to be enhanced for trigeminal stimuli, presumably due to their exceptional biological relevance. Y1 - 2016 U6 - https://doi.org/10.1016/j.neuroimage.2016.03.026 SN - 1053-8119 VL - 134 SP - 386 EP - 395 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Chen, Bixia A1 - Schoemberg, Tobias A1 - Kraff, Oliver A1 - Dammann, Philipp A1 - Bitz, Andreas A1 - Schlamann, Marc A1 - Quick, Harald H. A1 - Ladd, Mark E. A1 - Sure, Ulrich A1 - Wrede, Karsten H. T1 - Cranial fixation plates in cerebral magnetic resonance imaging: a 3 and 7 Tesla in vivo image quality study JF - Magnetic Resonance Materials in Physics, Biology and Medicine N2 - Objective This study assesses and quantifies impairment of postoperative magnetic resonance imaging (MRI) at 7 Tesla (T) after implantation of titanium cranial fixation plates (CFPs) for neurosurgical bone flap fixation. Materials and methods The study group comprised five patients who were intra-individually examined with 3 and 7 T MRI preoperatively and postoperatively (within 72 h/3 months) after implantation of CFPs. Acquired sequences included T₁-weighted magnetization-prepared rapid-acquisition gradient-echo (MPRAGE), T₂-weighted turbo-spin-echo (TSE) imaging, and susceptibility-weighted imaging (SWI). Two experienced neurosurgeons and a neuroradiologist rated image quality and the presence of artifacts in consensus reading. Results Minor artifacts occurred around the CFPs in MPRAGE and T2 TSE at both field strengths, with no significant differences between 3 and 7 T. In SWI, artifacts were accentuated in the early postoperative scans at both field strengths due to intracranial air and hemorrhagic remnants. After resorption, the brain tissue directly adjacent to skull bone could still be assessed. Image quality after 3 months was equal to the preoperative examinations at 3 and 7 T. Conclusion Image quality after CFP implantation was not significantly impaired in 7 T MRI, and artifacts were comparable to those in 3 T MRI. Y1 - 2016 U6 - https://doi.org/10.1007/s10334-016-0548-1 SN - 1352-8661 VL - 29 IS - 3 SP - 389 EP - 398 PB - Springer CY - Berlin ER - TY - JOUR A1 - Orzada, Stephan A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - A method to approximate maximum local SAR in multichannel transmit MR systems without transmit phase information JF - Magnetic Resonance in Medicine N2 - Purpose To calculate local specific absorption rate (SAR) correctly, both the amplitude and phase of the signal in each transmit channel have to be known. In this work, we propose a method to derive a conservative upper bound for the local SAR, with a reasonable safety margin without knowledge of the transmit phases of the channels. Methods The proposed method uses virtual observation points (VOPs). Correction factors are calculated for each set of VOPs that prevent underestimation of local SAR when the VOPs are applied with the correct amplitudes but fixed phases. Results The proposed method proved to be superior to the worst-case calculation based on the maximum eigenvalue of the VOPs. The mean overestimation for six coil setups could be reduced, whereas no underestimation of the maximum local SAR occurred. In the best investigated case, the overestimation could be reduced from a factor of 3.3 to a factor of 1.7. Conclusion The upper bound for the local SAR calculated with the proposed method allows a fast estimation of the local SAR based on power measurements in the transmit channels and facilitates SAR monitoring in systems that do not have the capability to monitor transmit phases Y1 - 2016 U6 - https://doi.org/10.1002/mrm.26398 SN - 1522-2594 VL - 78 IS - 2 SP - 805 EP - 811 PB - International Society for Magnetic Resonance in Medicine ER - TY - JOUR A1 - Lind, Thorsten Patric T1 - Rückzahlung von gewinnunabhängigen Ausschüttungen bei Auflösung einer stillen Gesellschaft : BGH, Versäumnisurteil vom 20.09.2016 - II ZR 120/15 (LG Berlin) : Anmerkung JF - Fachdienst Zivilrecht - LMK : kommentierte BGH-Rechtsprechung ; in Zsarb. mit der Neuen Juristischen Wochenschrift / Lindermaier-Möhring N2 - Zum Zweck der Kapitalanlage beteiligte sich der Bekl. an einer Publikumsgesellschaft. Diese war als (mehrgliedrige) atypische stille Gesellschaft organisiert (vgl. a. BGHZ 199, 104 = DNotZ 2014, 374 = NZG 2013, 1422 = DStR 2014, 45 Rn. 18). Der Gesellschaftsvertrag („GV“) sah für diejenigen Gesellschafter, die wie der Bekl. ihre Einlage in Form einer Einmaleinlage erbracht hatten, eine jährliche gewinnunabhängige Ausschüttung vor. Es sollte sich dabei ausdrücklich nicht um eine Garantieverzinsung handeln. Ende 2009 wurde die stille Gesellschaft durch Mehrheitsbeschluss der Stillen aufgelöst. Nach dem GV waren die Stillen im Falle ihres Ausscheidens sowie bei „Liquidation des Unternehmens“ des Geschäftsinhabers verhältnismäßig an dem jeweils seit ihrem Beitritt gebildeten Vermögen einschließlich der stillen Reserven sowie eines evtl. Geschäftswerts zu beteiligen (Auseinandersetzungswert). Den sich hiernach für den Bekl. auf seinem Kapitalkonto ergebenden Negativsaldo sollte dieser durch Erstattung der von ihm erhaltenen gewinnunabhängigen Auszahlungen ausgleichen. Anders als das LG als Berufungsinstanz bejahte der BGH auf Grundlage des GV einen Rückerstattungsanspruch der klagenden Geschäftsinhaberin. Y1 - 2016 PB - Beck CY - München ER - TY - CHAP A1 - Droszez, Anna A1 - Sanno, Maximilian A1 - Goldmann, Jan-Peter A1 - Albracht, Kirsten A1 - Brüggemann, Gerd-Peter A1 - Braunstein, Bjoern T1 - Differences between take-off behavior during vertical jumps and two artistic elements T2 - 34th International Conference of Biomechanics in Sport, Tsukuba, Japan, July 18-22, 2016 Y1 - 2016 SN - 1999-4168 SP - 577 EP - 580 ER - TY - JOUR A1 - Kolditz, Melanie A1 - Albin, Thivaharan A1 - Brüggemann, Gert-Peter A1 - Abel, Dirk A1 - Albracht, Kirsten T1 - Robotergestütztes System für ein verbessertes neuromuskuläres Aufbautraining der Beinstrecker JF - at - Automatisierungstechnik N2 - Neuromuskuläres Aufbautraining der Beinstrecker ist ein wichtiger Bestandteil in der Rehabilitation und Prävention von Muskel-Skelett-Erkrankungen. Effektives Training erfordert hohe Muskelkräfte, die gleichzeitig hohe Belastungen von bereits geschädigten Strukturen bedeuten. Um trainingsinduzierte Schädigungen zu vermeiden, müssen diese Kräfte kontrolliert werden. Mit heutigen Trainingsgeräten können diese Ziele allerdings nicht erreicht werden. Für ein sicheres und effektives Training sollen durch den Einsatz der Robotik, Sensorik, eines Regelkreises sowie Muskel-Skelett-Modellen Belastungen am Zielgewebe direkt berechnet und kontrolliert werden. Auf Basis zweier Vorstudien zu möglichen Stellgrößen wird der Aufbau eines robotischen Systems vorgestellt, das sowohl für Forschungszwecke als auch zur Entwicklung neuartiger Trainingsgeräte verwendet werden kann. Y1 - 2016 U6 - https://doi.org/10.1515/auto-2016-0044 SN - 2196-677X VL - 64 IS - 11 SP - 905 EP - 914 PB - De Gruyter CY - Berlin ER - TY - RPRT A1 - Damm, Marc André A1 - Anthrakidis, Anette A1 - Fend, Thomas T1 - Keramische Porenkörpersysteme als SCR-Mischer und Hydrolysekatalysator : BMBF-Projekt: Hydromix : Schlussbericht : Laufzeit: 01.10.2011 bis 31.03.2015 Y1 - 2016 CY - Aachen ER - TY - BOOK A1 - Bleninger, T. A1 - Brenda, M. A1 - Bung, Daniel Bernhard A1 - Hengl, M. A1 - Schmid, B.H. A1 - Schneider, E. A1 - Sonnenburg, A. A1 - Stoschek, O. T1 - DWA-Regelwerk M 544-2 : Merkblatt: Ausbreitungsprobleme von Einleitungen - Prozesse, Methoden und Modelle - Teil 2: Mehrdimensionale Modelle Y1 - 2016 SN - 978-3-88721-281-0 CY - Hennef ER -