TY - JOUR A1 - Šakić, Bogdan A1 - Marinković, Marko A1 - Butenweg, Christoph A1 - Klinkel, Sven ED - Yang, J. T1 - Influence of slab deflection on the out-of-plane capacity of unreinforced masonry partition walls JF - Engineering Structures N2 - Severe damage of non-structural elements is noticed in previous earthquakes, causing high economic losses and posing a life threat for the people. Masonry partition walls are one of the most commonly used non-structural elements. Therefore, their behaviour under earthquake loading in out-of-plane (OOP) direction is investigated by several researches in the past years. However, none of the existing experimental campaigns or analytical approaches consider the influence of prior slab deflection on OOP response of partition walls. Moreover, none of the existing construction techniques for the connection of partition walls with surrounding reinforced concrete (RC) is investigated for the combined slab deflection and OOP loading. However, the inevitable time-dependent behaviour of RC slabs leads to high values of final slab deflections which can further influence boundary conditions of partition walls. Therefore, a comprehensive study on the influence of slab deflection on the OOP capacity of masonry partitions is conducted. In the first step, experimental tests are carried out. Results of experimental tests are further used for the calibration of the numerical model employed for a parametric study. Based on the results, behaviour under combined loading for different construction techniques is explained. The results show that slab deflection leads either to severe damage or to a high reduction of OOP capacity. Existing practical solutions do not account for these effects. In this contribution, recommendations to overcome the problems of combined slab deflection and OOP loading on masonry partition walls are given. Possible interaction of in-plane (IP) loading, with the combined slab deflection and OOP loading on partition walls, is not investigated in this study. KW - Masonry partition walls KW - Earthquake KW - Out-of-plane capacity KW - Slab deflection Y1 - 2023 U6 - http://dx.doi.org/10.1016/j.engstruct.2022.115342 SN - 0141-0296 VL - 276 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Özsoylu, Dua A1 - Kizildag, Sefa A1 - Schöning, Michael Josef A1 - Wagner, Torsten T1 - Differential chemical imaging of extracellular acidification within microfluidic channels using a plasma-functionalized light-addressable potentiometric sensor (LAPS) JF - Physics in Medicine N2 - Extracellular acidification is a basic indicator for alterations in two vital metabolic pathways: glycolysis and cellular respiration. Measuring these alterations by monitoring extracellular acidification using cell-based biosensors such as LAPS plays an important role in studying these pathways whose disorders are associated with numerous diseases including cancer. However, the surface of the biosensors must be specially tailored to ensure high cell compatibility so that cells can represent more in vivo-like behavior, which is critical to gain more realistic in vitro results from the analyses, e.g., drug discovery experiments. In this work, O2 plasma patterning on the LAPS surface is studied to enhance surface features of the sensor chip, e.g., wettability and biofunctionality. The surface treated with O2 plasma for 30 s exhibits enhanced cytocompatibility for adherent CHO–K1 cells, which promotes cell spreading and proliferation. The plasma-modified LAPS chip is then integrated into a microfluidic system, which provides two identical channels to facilitate differential measurements of the extracellular acidification of CHO–K1 cells. To the best of our knowledge, it is the first time that extracellular acidification within microfluidic channels is quantitatively visualized as differential (bio-)chemical images. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.phmed.2020.100030 SN - 2352-4510 VL - 10 IS - 100030 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Özsoylu, Dua A1 - Kizildag, Sefa A1 - Schöning, Michael Josef A1 - Wagner, Torsten T1 - Effect of plasma treatment on the sensor properties of a light‐addressable potentiometric sensor (LAPS) JF - physica status solidi a : applications and materials sciences N2 - A light-addressable potentiometric sensor (LAPS) is a field-effect-based (bio-) chemical sensor, in which a desired sensing area on the sensor surface can be defined by illumination. Light addressability can be used to visualize the concentration and spatial distribution of the target molecules, e.g., H+ ions. This unique feature has great potential for the label-free imaging of the metabolic activity of living organisms. The cultivation of those organisms needs specially tailored surface properties of the sensor. O2 plasma treatment is an attractive and promising tool for rapid surface engineering. However, the potential impacts of the technique are carefully investigated for the sensors that suffer from plasma-induced damage. Herein, a LAPS with a Ta2O5 pH-sensitive surface is successfully patterned by plasma treatment, and its effects are investigated by contact angle and scanning LAPS measurements. The plasma duration of 30 s (30 W) is found to be the threshold value, where excessive wettability begins. Furthermore, this treatment approach causes moderate plasma-induced damage, which can be reduced by thermal annealing (10 min at 300 °C). These findings provide a useful guideline to support future studies, where the LAPS surface is desired to be more hydrophilic by O2 plasma treatment. Y1 - 2019 U6 - http://dx.doi.org/10.1002/pssa.201900259 SN - 1862-6319 N1 - Corresponding author: Torsten Wagner VL - 216 IS - 20 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Öhlschläger, Peter A1 - Steinberg, Thorsten A1 - Sehr, Peter A1 - Osen, Wolfram T1 - Modification of HPV 16 E7 genes: correlation between the level of protein expression and CTL response after immunization of C57BL/6 mice / Steinberg, Thorsten ; Öhlschläger, Peter ; Sehr, Peter ; Osen, Wolfram ; Gissmann, Lutz JF - Vaccine. 23 (2005), H. 9 Y1 - 2005 SN - 0264-410X SP - 1149 EP - 1157 ER - TY - JOUR A1 - Öhlschläger, Peter A1 - Spies, Elmar A1 - Alvarez, Gerardo A1 - Quetting, Michael A1 - Groettrup, Marcus T1 - The combination of TLR-9 adjuvantation and electroporation-mediated delivery enhances in vivo antitumor responses after vaccination with HPV-16 E7 encoding DNA JF - International Journal of Cancer. 128 (2011), H. 2 Y1 - 2011 SN - 1097-0215 SP - 473 EP - 481 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Öhlschläger, Peter A1 - Quetting, Michael A1 - Alvarez, Gerardo A1 - Dürst, Matthias A1 - Gissmann, Lutz A1 - Kaufmann, Andreas M. T1 - Enhancement of immunogenicity of a therapeutic cervical cancer DNA-based vaccine by co-application of sequence-optimized genetic adjuvants JF - International Journal of Cancer Y1 - 2009 SN - 1097-0215 VL - 125 IS - 1 SP - 189 EP - 198 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Öhlschläger, Peter A1 - Pes, Michaela A1 - Osen, Wolfram A1 - Dürst, Matthias T1 - An improved rearranged Human Papillomavirus Type 16 E7 DNA vaccine candidate (HPV-16 E7SH) induces an E7 wildtype-specific T cell response / Öhlschläger, Peter ; Pes, Michaela ; Osen, Wolfram ; Dürst, Matthias ; Schneider, Achim ; Gissmann, Lutz ; Kaufman JF - Vaccine. 24 (2006), H. 15 Y1 - 2006 SN - 0264-410X SP - 2880 EP - 2893 ER - TY - JOUR A1 - Öhlschläger, Peter A1 - Osen, Wolfram A1 - Peiler, Tanja A1 - Caldeira, Sandra T1 - A DNA vaccine based on a shuffled E7 oncogene of the human papillomavirus type 16 (HPV 16) induces E7-specific cytotoxic T cells but lacks transforming activity / Osen, Wolfram ; Peiler, Tanja ; Öhlschläger, Peter ; Caldeira, Sandra ; Faath, Stefan ; Mich JF - Vaccine. 19 (2001), H. 20 Y1 - 2001 SN - 0264-410X SP - 4276 EP - 4286 ER - TY - JOUR A1 - Öhlschläger, Peter A1 - Osen, Wolfram A1 - Dell, Kerstin A1 - Faath, Stefan T1 - Human papillomavirus type 16 L1 capsomeres induce L1-specific cytotoxic T lymphocytes and tumor regression in C57BL/6 mice / Öhlschläger, Peter ; Osen, Wolfram ; Dell, Kerstin ; Faath, Stefan ; Garcea Robert L: ; Jochmus, Ingrid ; Müller, Martin, Pawlita, JF - Journal of Virology. 77 (2003), H. 8 Y1 - 2003 SN - 1098-5514 SP - 4635 EP - 4645 ER - TY - JOUR A1 - Öhlschläger, Peter A1 - Michel, Nico A1 - Osen, Wolfram A1 - Freyschmidt, Eva-Jasmin T1 - T cell response to human papillomavirus 16 E7 in mice: comparison of Cr release assay, intracellular IFN-gamma production, ELISPOT and tetramer staining / Michel, Nico ; Öhlschläger, Peter ; Osen, Wolfram ; Freyschmidt, Eva-Jasmin ; Gutöhrlein, Heidrun ; JF - Intervirology. 45 (2002) Y1 - 2002 SN - 1423-0100 SP - 290 EP - 299 ER - TY - JOUR A1 - Öhlschläger, Peter A1 - Corvinus, Florian M. A1 - Orth, Carina A1 - Moriggl, Richard T1 - Persistent STAT3 activation in colon cancer is associated with enhanced cell proliferation and tumor growth / Corvinus, Florian, Moriggl, Richard ; Tsareva, Svetlana A. ; Wagner, Stefan ; Pfitzner, Edith B. ; Baus, Daniela ; Kaufmann, Roland : Huber, Luka JF - Neoplasia. 7 (2005), H. 6 Y1 - 2005 SN - 1476-5586 SP - 545 EP - 555 ER - TY - JOUR A1 - Zischank, Wolfgang J. A1 - Heidler, Fridolin A1 - Wiesinger, J. A1 - Metwally, I. A1 - Kern, Alexander A1 - Seevers, M. T1 - Laboratory simulation of direct lightning strokes to a modeled building : measurement of magnetic fields and included voltages JF - Journal of electrostatics. 60 (2004), H. 2 - 4 Y1 - 2004 SN - 0304-3886 N1 - ISSN der E-Ausg.: 0304-3886 SP - 223 EP - 232 ER - TY - JOUR A1 - Zimmermann, Doris T1 - [Kapitel 7] : Externes Rechnungswesen JF - Business-Management für Ingenieure : beurteilen - entscheiden - gestalten / Rolf Grap (Hrsg.). - (REFA-Fachbuchreihe Unternehmensentwicklung) Y1 - 2007 SN - 978-3-446-41256-9 N1 - ISBN 10: 3-446-41256-5 SP - 208 EP - 273 PB - Hanser CY - München ER - TY - JOUR A1 - Ziller, Claudia A1 - Döring, Bernd T1 - Doppelfassaden - vom Experimentalmodell zum Massanzug JF - TAB Technik am Bau Y1 - 2004 SN - 0341-2032 VL - Bd. 35 IS - H. 12 SP - 58 EP - 63 ER - TY - JOUR A1 - Zientz, Evelyn A1 - Bongaerts, Johannes A1 - Unden, Gottfried T1 - Fumarate regulation of gene expression in Escherichia coli by the DcuSR (dcuSR genes) two-component regulatory system JF - Journal of bacteriology Y1 - 1998 SN - 1098-5530 (E-Journal); 0021-9193 (Print) VL - Vol. 180 IS - No. 20 SP - 5421 EP - 5425 ER - TY - JOUR A1 - Ziemons, Karl A1 - Kleines, H. A1 - Erken, I. A1 - Knoben, J. A1 - Zwoll, K. ED - Lehmann, Thomas T1 - IME-DV Projekt: M-FIRBe, Multi-Modality Functional Imaging for Brain Research JF - Bildverarbeitung für die Medizin : Algorithmen - Systeme - Anwendungen Y1 - 1997 SN - 3-86073-519-5 N1 - Proceedings des Aachener Workshops am 8. u. 9. November 1996 ; WG_005 Arbeitsgruppenvorstellungen SP - 363 EP - 366 PB - Verl. der. Augustinus-Buchh. CY - Aachen ER - TY - JOUR A1 - Ziemons, Karl A1 - Herzog, H. A1 - Feinendegen, L. E. T1 - Iterative image reconstruction with weighted pixel contribution to projection element JF - European Journal of Nuclear Medicine Y1 - 1990 SN - 1619-7089 N1 - Abstracts of the European Association of Nuclear Medicine Congress ; V52 VL - 16 IS - 7 SP - 403 EP - 403 ER - TY - JOUR A1 - Ziemons, Karl A1 - Herzog, H. A1 - Bosetti, P. A1 - Feinendegen, L. E. T1 - Iterative image reconstruction with weighted pixel contribution to projection elements JF - European Journal of Nuclear Medicine Y1 - 1992 SN - 1619-7089 N1 - Abstracts of the European Association of Nuclear Medicine Congress 23–26 August 1992 Lisboa, Portugal ; V143-2 VL - 19 IS - 8 SP - 588 EP - 588 ER - TY - JOUR A1 - Ziemons, Karl A1 - Heinrichs, U. A1 - Streun, M. A1 - Pietrzyk, U. T1 - Validation of GEANT3 simulation studies with a dual-head PMT ClearPET™ prototype JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry. Y1 - 2004 SN - 1082-3654 SP - 3053 EP - 3056 ER - TY - JOUR A1 - Ziemons, Karl A1 - Bruyndonckx, P. A1 - Perez, J. M. A1 - Pietrzyk, U. A1 - Rato, P. A1 - Tavernier, S. T1 - Beyond ClearPET: Next Aims JF - 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro Symposium Proceedings ISBI 2008 N2 - The CRYSTAL CLEAR collaboration, in short CCC, is a consortium of 12 academic institutions, mainly from Europe, joining efforts in the area of developing instrumentation for nuclear medicine and medical imaging. In the framework of the CCC a high performance small animal PET system, called ClearPET, was developed by using new technologies in electronics and crystals in a phoswich arrangement combining two types of lutetium- based scintillator materials: LSO:Ce and LuYAP:Ce. Our next aim will be the development of hybrid image systems. Hybrid MR-PET imaging has many unique advantages for brain research. This has sparked a new research line within CCC for the development of novel MR-PET compatible technologies. MRI is not as sensitive as PET but PET has poorer spatial resolution than MRI. Two major advantages of PET are sensitivity and its ability to acquire metabolic information. To assess these innovations, the development of a 9.4T hybrid animal MR-PET scanner is proposed based on an existing 9.4T MR scanner that will be adapted to enable simultaneous acquisition of MR and PET data using cutting- edge technology for both MR and PET. Y1 - 2008 SN - 978-1-4244-2003-2 SP - 1421 EP - 1424 ER - TY - JOUR A1 - Ziemons, Karl A1 - Berghoff, G. A1 - Lanske, D. A1 - Schultze, K. T1 - Strangeness production in deep inelastic muon-nucleon scattering JF - Verhandlungen der Deutschen Physikalischen Gesellschaft Y1 - 1988 SN - 0420-0195 VL - 23 IS - 5 SP - T309 EP - T309 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. A1 - Bruyndonckx, P. T1 - The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Second generation high-performance PET scanners, called ClearPET™1, have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and high spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8×8 crystals of 2×2×10 mm3 are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm.The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time, which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view. Preliminary data shows a correct identification of the crystal layer about (98±1)%. Typically the energy resolution is (23.3±0.5)% for the luyap layer and (15.4±0.4)% for the lso layer. early studies showed the timing resolution of 2 ns FWHM and 4.8 ns FWTM. the intrinsic spatial resolution ranges from 1.37 mm to 1.61 mm full-width of half-maximum (FWHM) with a mean of 1.48 mm FWHM. further improvements in image and energy resolution are expected when the system geometry is fully modeled. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 307 EP - 311 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. T1 - The ClearPET TM LSO/LuYAP phoswich scanner: a high performance small animal PET system JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes. Y1 - 2004 SN - 1082-3654 SP - 1728 EP - 1732 ER - TY - JOUR A1 - Ziemons, Karl A1 - Achten, R. A1 - Auffray, E. A1 - Müller-Veggian, Mattea T1 - The ClearPET™ neuro scanner: a dedicated LSO/LuYAP phoswich small animal PET scanner JF - 2004 IEEE Nuclear Science Symposium conference record : Nuclear Science Symposium, Medical Imaging Conference ; 16 - 22 October 2004, Rome, Italy ; [including the Symposium on Nuclear Power System (SNPS), 14th Room Temperature Semiconductor X- and Gamma-Ray Detectors Workshop and special focus workshops] / NPSS, Nuclear & Plasma Sciences Society. Guest ed.: J. Anthony Seibert Y1 - 2004 SN - 1082-3654 N1 - Nuclear Science Symposium Conference Record, 2004 IEEE SP - 2430 EP - 2433 PB - IEEE Operations Center CY - Piscataway, NJ ER - TY - JOUR A1 - Ziemons, Karl T1 - Jet production and fragmentation properties in deep inelastic muon scattering JF - Zeitschrift für Physik C : Particles and Fields Y1 - 1987 SN - 0170-9739 N1 - European Muon Collaboration VL - 36 IS - 4 SP - 527 EP - 543 ER - TY - JOUR A1 - Ziemons, Karl T1 - A measurement of the spin asymmetry of the structure function g1 in deep inelastic muon-proton scattering JF - Physics Letters B N2 - The spin asymmetry in deep inelastic scattering of longitudinally polarised muons by longitudinally polarised protons has been measured over a large x range (0.01 SP - 421 EP - 434 PB - Akad. Kiadó CY - Budapest ER - TY - JOUR A1 - Zastrow, Udo A1 - Rieder, G. T1 - Eine Variante des Kraftgrößenverfahrens für ebene Rahmentragwerke JF - Wissenschaftliche Zeitschrift / Hochschule für Architektur und Bauwesen Y1 - 1976 SN - 0509-9773 VL - 23 IS - 3 SP - 304 EP - 306 PB - HAB CY - Weimar ER - TY - JOUR A1 - Zastrow, Udo A1 - Rieder, G. T1 - Zur Eingrenzung der Eigenfrequenzen eines stationär schwingenden elastischen Körpers mittels Integralgleichungen JF - ZAMM - Zeitschrift für angewandte Mathematik und Mechanik. 60 (1980), H. 6 Y1 - 1980 SN - 1521-4001 SP - T149 EP - T150 ER - TY - JOUR A1 - Zastrow, Udo A1 - Panagiotopoulos, P. D. T1 - An integral "Equation" approach to the unilateral contact problem JF - ZAMM - Zeitschrift für angewandte Mathematik und Mechanik. 59 (1979), H. 8 Y1 - 1979 SN - 1521-4001 SP - 392 EP - 393 ER - TY - JOUR A1 - Zastrow, Udo A1 - Hackl, Klaus T1 - On the existence, uniqueness and completeness of displacements and stress functions in linear elasticity / Hackl, Klaus ; Zastrow, Udo JF - Journal of Elasticity. 19 (1988), H. 1 Y1 - 1988 SN - 1573-2681 SP - 3 EP - 23 ER - TY - JOUR A1 - Zastrow, Udo A1 - Greuel, M. A1 - Weiße, Felicitas T1 - Das Kawabata-Meßgeräte- und Berechnungssystem: Der Griff eines Gewebes - subjektive Beurteilung und objektive Messung, Teil 1 JF - Bekleidung + Wäsche, Bekleidung + Maschenware : Zeitschrift für die gesamte Bekleidungsindustrie. 43 (1991), H. 4 Y1 - 1991 SP - 22 EP - 25 ER - TY - JOUR A1 - Zastrow, Udo A1 - Greuel, M. A1 - Weiße, Felicitas T1 - Das Kawabata-Meßgeräte- und Berechnungssystem: Der Griff eines Gewebes - subjektive Beurteilung und objektive Messung, Teil 2 JF - Bekleidung + Wäsche, Bekleidung + Maschenware : Zeitschrift für die gesamte Bekleidungsindustrie. 43 (1991), H. 5 Y1 - 1991 SP - 36 EP - 45 ER - TY - JOUR A1 - Zastrow, Udo T1 - On the formulation of the fundamental solutions for orthotropic plane elasticity JF - Acta Mechanica. 57 (1985), H. 3-4 Y1 - 1985 SN - 1619-6937 SP - 113 EP - 122 ER - TY - JOUR A1 - Zastrow, Udo T1 - On the complete system of fundamental solutions for anisotropic slices and slabs: A comparison by use of the slab analogy JF - Journal of Elasticity. 15 (1985), H. 3 Y1 - 1985 SN - 1573-2681 SP - 293 EP - 318 ER - TY - JOUR A1 - Zastrow, Udo T1 - Basic geometrical singularities in plane-elasticity and plate-bending problems JF - International Journal of Solids and Structures. 21 (1985), H. 10 Y1 - 1985 SN - 0020-7683 SP - 1047 EP - 1067 ER - TY - JOUR A1 - Zastrow, Udo T1 - Numerical plane stress analysis by integral equations based on the singularity method JF - SM archives . 10 (1985) Y1 - 1985 SN - 0376-7426 SP - 113 EP - 128 ER - TY - JOUR A1 - Zastrow, Udo T1 - Zur Berechnung anisotroper Scheiben durch singuläre Integralgleichungen JF - ZAMM - Zeitschrift für Angewandte Mathematik und Mechanik. Y1 - 1978 SN - 1521-4001 U6 - http://dx.doi.org/10.1002/zamm.19780580605 VL - 58 IS - 6 SP - T132 EP - T133 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Zastrow, Udo T1 - Anisotrope Scheiben mit gemischten Randbedingungen JF - ZAMM - Zeitschrift für Angewandte Mathematik und Mechanik. 59 (1979), H. 5 Y1 - 1979 SN - 1521-4001 SP - T218 EP - T219 ER - TY - JOUR A1 - Zastrow, Udo T1 - Die Airysche Spannungsfunktion für die unendliche anisotrope, orthotrope und isotrope Scheibe JF - ZAMM - Zeitschrift für Angewandte Mathematik und Mechanik. 60 (1980), H. 6 Y1 - 1980 SN - 1521-4001 SP - T159 EP - T160 ER - TY - JOUR A1 - Zastrow, Udo T1 - Die Einflußfunktionen der Einzelkraft und der Stufenversetzung in der anisotropen Vollebene JF - Archive of Applied Mechanics - Ingenieur Archiv. 51 (1981), H. 1-2 Y1 - 1981 SN - 1432-0681 SP - 89 EP - 99 ER - TY - JOUR A1 - Zastrow, Udo T1 - Zum System der Einflußfunktionen für die unendliche anisotrope Scheibe mit statischen und geometrischen Singularitäten JF - Archive of Applied Mechanics - Ingenieur Archiv. 55 (1985), H. 2 Y1 - 1985 SN - 1432-0681 SP - 124 EP - 133 ER - TY - JOUR A1 - Zastrow, Udo T1 - Solution of plane anisotropic elastostatical boundary value problems by singular integral equations JF - Acta Mechanica. 44 (1982), H. 1-2 Y1 - 1982 SN - 1619-6937 SP - 59 EP - 71 ER - TY - JOUR A1 - Zange, Jochen A1 - Schopen, Kathrin A1 - Albracht, Kirsten A1 - Gerlach, Darius A. A1 - Frings-Meuthen, Petra A1 - Maffiuletti, Nicola A. A1 - Bloch, Wilhelm A1 - Rittweger, Jörn T1 - Using the Hephaistos orthotic device to study countermeasure effectiveness of neuromuscular electrical stimulation and dietary lupin protein supplementation, a randomised controlled trial JF - Plos one Y1 - 2017 U6 - http://dx.doi.org/10.1371/journal.pone.0171562 VL - 12 IS - 2 ER - TY - JOUR A1 - Zabirov, Alexander A1 - Schleser, Markus A1 - Bucherer, Sebastian T1 - Füge- und Dichtkonzept für einen Leichtbauverbrennungsmotor JF - adhäsion KLEBEN & DICHTEN Y1 - 2021 U6 - http://dx.doi.org/10.1007/s35145-021-0531-5 SN - 2192-8681 VL - 65 IS - 11 SP - 12 EP - 19 PB - Springer Nature CY - Cham ER - TY - JOUR A1 - Yoshinobu, Tatsuo A1 - Schöning, Michael Josef T1 - Light-addressable potentiometric sensors (LAPS) for cell monitoring and biosensing JF - Current Opinion in Electrochemistry Y1 - 2021 U6 - http://dx.doi.org/10.1016/j.coelec.2021.100727 SN - 2451-9103 IS - In Press, Journal Pre-proof PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Yoshinobu, Tatsuo A1 - Moritz, Werner A1 - Finger, Friedhelm A1 - Schöning, Michael Josef ED - Comini, Elisabetta T1 - Application of thin-film amorphous silicon to chemical imaging JF - Nanostructured materials and hybrid composites for gas sensors and biomedical applications : symposium held April 18-20, 2006, San Francisco , California, U.S.A. Y1 - 2006 SN - 9781558998711 N1 - Materials Research Society symposia proceedings; v. 915 IS - Paper 0910-A-20-01 SP - 1 EP - 10 ER - TY - JOUR A1 - Yoshinobu, Tatsuo A1 - Miyamoto, Ko-ichiro A1 - Werner, Frederik A1 - Poghossian, Arshak A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Light-addressable potentiometric sensors for quantitative spatial imaging of chemical species JF - Annual Review of Analytical Chemistry N2 - A light-addressable potentiometric sensor (LAPS) is a semiconductor-based chemical sensor, in which a measurement site on the sensing surface is defined by illumination. This light addressability can be applied to visualize the spatial distribution of pH or the concentration of a specific chemical species, with potential applications in the fields of chemistry, materials science, biology, and medicine. In this review, the features of this chemical imaging sensor technology are compared with those of other technologies. Instrumentation, principles of operation, and various measurement modes of chemical imaging sensor systems are described. The review discusses and summarizes state-of-the-art technologies, especially with regard to the spatial resolution and measurement speed; for example, a high spatial resolution in a submicron range and a readout speed in the range of several tens of thousands of pixels per second have been achieved with the LAPS. The possibility of combining this technology with microfluidic devices and other potential future developments are discussed. Y1 - 2017 U6 - http://dx.doi.org/10.1146/annurev-anchem-061516-045158 SN - 1936-1327 VL - 10 SP - 225 EP - 246 PB - Annual Reviews CY - Palo Alto, Calif. ER - TY - JOUR A1 - Yoshinobu, Tatsuo A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Recent developments of chemical imaging sensor systems based on the principle of the light-addressable potentiometric sensor JF - Sensors and actuators B: Chemical N2 - The light-addressable potentiometric sensor (LAPS) is an electrochemical sensor with a field-effect structure to detect the variation of the Nernst potential at its sensor surface, the measured area on which is defined by illumination. Thanks to this light-addressability, the LAPS can be applied to chemical imaging sensor systems, which can visualize the two-dimensional distribution of a particular target ion on the sensor surface. Chemical imaging sensor systems are expected to be useful for analysis of reaction and diffusion in various electrochemical and biological samples. Recent developments of LAPS-based chemical imaging sensor systems, in terms of the spatial resolution, measurement speed, image quality, miniaturization and integration with microfluidic devices, are summarized and discussed. Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.snb.2014.09.002 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - 207, Part B SP - 926 EP - 932 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Yoshinobu, Tatsuo A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Field-effect sensors combined with the scanned light pulse technique: from artificial olfactory images to chemical imaging technologies JF - Chemosensors N2 - The artificial olfactory image was proposed by Lundström et al. in 1991 as a new strategy for an electronic nose system which generated a two-dimensional mapping to be interpreted as a fingerprint of the detected gas species. The potential distribution generated by the catalytic metals integrated into a semiconductor field-effect structure was read as a photocurrent signal generated by scanning light pulses. The impact of the proposed technology spread beyond gas sensing, inspiring the development of various imaging modalities based on the light addressing of field-effect structures to obtain spatial maps of pH distribution, ions, molecules, and impedance, and these modalities have been applied in both biological and non-biological systems. These light-addressing technologies have been further developed to realize the position control of a faradaic current on the electrode surface for localized electrochemical reactions and amperometric measurements, as well as the actuation of liquids in microfluidic devices. KW - visualization KW - light-addressing technologies KW - scanned light pulse technique KW - field-effect structure KW - MOS KW - metal-oxide-semiconductor structure KW - catalytic metal KW - electronic nose KW - gas sensor KW - artificial olfactory image Y1 - 2024 U6 - http://dx.doi.org/10.3390/chemosensors12020020 SN - 2227-9040 N1 - This article belongs to the Special Issue "An Exciting Journey of Chemical Sensors and Biosensors: A Theme Issue in Honor of Professor Ingemar Lundström" Corresponding author: Tatsuo Yoshinobu, Michael J. Schöning VL - 12 IS - 2 PB - MDPI CY - Basel ER - TY - JOUR A1 - Yoshinobu, T. A1 - Yasuhito, U. A1 - Iwasaki, H. A1 - Näther, Niko A1 - Schöning, Michael Josef A1 - Koudelka-Hep, M. T1 - Applications of the light-addressable potentiometric sensor to microfluidic devices JF - Digest of technical papers : September 12 - 15, 2004, Rome, Italy, Pontificia Universitas Sancto Thoma Aquinate in Urbe / [conference chairperson: C. Di Natale]. Y1 - 2004 SN - 88-7621-282-5 N1 - Eurosensors ; (18, 2004, Roma) SP - 434 EP - 437 CY - Roma ER - TY - JOUR A1 - Yoshinobu, T. A1 - Ui, Y. A1 - Iwasaki, H. A1 - Näther, Niko A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - Potentiometric imaging in a microfluidic channel JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 998 EP - 999 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Schöning, Michael Josef A1 - Otto, R. A1 - Furuichi, K. A1 - Mourzina, Yu A1 - Ermelenko, Yu A1 - Iwasaki, I. T1 - Portable light-addressable potentiometric sensor (LAPS) for multisensor applications JF - Book of abstracts / ed. by J. Saneistr. Y1 - 2002 SN - 80-01-02576-4 N1 - Eurosensors ; (16, 2002, Praha) SP - 898 EP - 901 PB - Czech Technical University, Faculty of Electrical Engineering, Department of Measurement CY - Prague ER - TY - JOUR A1 - Yoshinobu, T. A1 - Schöning, Michael Josef A1 - Otto, R. A1 - Furuichi, K. A1 - Mourzina, Y. A1 - Ermelenko, Y. A1 - Iwasaki, H. T1 - Portable light-addressable potentiometric sensor (LAPS) for multisensor applications JF - Sensors and Actuators B. 95 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 352 EP - 356 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Schöning, Michael Josef A1 - Finger, F. A1 - Moritz, W. A1 - Iwasaki, H. T1 - Fabrication of thin-film LAPS with amorphous silicon JF - Sensors. 4 (2004), H. 10 Y1 - 2004 SN - 1424-8220 SP - 163 EP - 169 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Iwasaki, H. A1 - Ui, Y. A1 - Furuichi, K. A1 - Ermelenko, Y. A1 - Mourzina, Y. A1 - Wagner, Torsten A1 - Näther, Niko A1 - Schöning, Michael Josef T1 - The light-addressable potentiometric sensor for multi-ion sensing and imaging JF - Methods. 37 (2005), H. 1 Y1 - 2005 SN - 1046-2023 SP - 99 EP - 102 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Ermelenko, Y. A1 - Mourzina, Y. A1 - Schöning, Michael Josef A1 - Iwasaki, H. A1 - Vlasov, Y. T1 - Multi-component analysis based on the light-addressable potentiometric sensor (LAPS) JF - Proceedings : 11th international conference Sensor 2003; 13 - 15 May 2003, Exhibition Centre Nuremberg, Germany Y1 - 2003 N1 - Internationale Messe mit Kongress Sensor <11, 2003, Nürnberg> SP - 141 EP - 144 PB - AMA Service CY - Wunstorf ER - TY - JOUR A1 - Yoshinobu, T. A1 - Ecken, H. A1 - Poghossian, Arshak A1 - Simonis, A. A1 - Iwasaki, H. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Constant-current-mode LAPS (CLAPS) for the detection of penicillin JF - Electroanalysis. 13 (2001), H. 8-9 Y1 - 2001 SN - 1040-0397 SP - 733 EP - 736 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Ecken, H. A1 - Poghossian, Arshak A1 - Lüth, H. A1 - Iwasaki, H. A1 - Schöning, Michael Josef T1 - Alternative sensor materials for light-addressable potentiometric sensors JF - Sensors and Actuators B. 76 (2001), H. 1-3 Y1 - 2001 SN - 0925-4005 SP - 388 EP - 392 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Ecken, H. A1 - Ismail, Md.A.B. A1 - Iwasaki, H. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Chemical imaging sensor and its application to biological systems JF - Scaling down in electrochemistry : electrochemical micro- and nanosystem technology ; proceedings of the 3rd International Symposium on Electrochemical Microsystem Technologies, Garmisch-Patenkirchen, Germany, 11 - 15 September 2000 / ed. by J. W. Schultz Y1 - 2001 SN - 0-08-044014-2 SP - 259 EP - 263 PB - Elsevier [u.a.] CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Yazdanbakhsh, Pedram A1 - Solbach, Klaus A1 - Bitz, Andreas T1 - Variable power combiner for RF mode shimming in 7-T MR imaging JF - IEEE Transaction on Biomedical Engineering N2 - This contribution discusses the utilization of RF power in an MRI system with RF mode shimming which enables the superposition of circularly polarized modes of a transmit RF coil array driven by a Butler matrix. Since the required power for the individual modes can vary widely, mode-shimming can result in a significant underutilization of the total available RF power. A variable power combiner (VPC) is proposed to improve the power utilization: it can be realized as a reconfiguration of the MRI transmit system by the inclusion of one additional matrix network which receives the power from all transmit amplifiers at its input ports and provides any desired (combined) power distribution at its output ports by controlling the phase and amplitude of the amplifiers’ input signals. The power distribution at the output ports of the VPC is then fed into the “mode” ports of the coil array Butler matrix in order to superimpose the spatial modes at the highest achievable power utilization. The VPC configuration is compared to the standard configuration of the transmit chain of our MRI system with 8 transmit channels and 16 coils. In realistic scenarios, improved power utilization was achieved from 17% to 60% and from 14% to 55% for an elliptical phantom and a region of interest in the abdomen, respectively, and an increase of the power utilization of 1 dB for a region of interest in the upper leg. In general, it is found that the VPC allows significant improvement in power utilization when the shimming solution demands only a few modes to be energized, while the technique can yield loss in power utilization in cases with many modes required at high power level. Y1 - 2012 U6 - http://dx.doi.org/10.1109/TBME.2012.2205926 SN - 1558-2531 VL - 59 IS - 9 SP - 2549 EP - 2557 PB - IEEE CY - New York ER - TY - JOUR A1 - Yang, Peng-Fei A1 - Kriechbaumer, Andreas A1 - Albracht, Kirsten A1 - Sanno, Maximilian A1 - Ganse, Bergita A1 - Koy, Timmo A1 - Shang, Peng A1 - Brüggemann, Gert-Peter A1 - Müller, Lars Peter A1 - Rittweger, Jörn T1 - On the relationship between tibia torsional deformation and regional muscle contractions in habitual human exercises in vivo JF - Journal of Biomechanics Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.jbiomech.2014.12.031 SN - 0021-9290 VL - 48 IS - 3 SP - 456 EP - 464 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Yang, Peng-Fei A1 - Kriechbaumer, Andreas A1 - Albracht, Kirsten A1 - Sanno, Maximilian A1 - Ganse, Bergita A1 - Koy, Timmo A1 - Shang, Peng A1 - brüggemann, Gert-Peter A1 - Müller, Lars Peter A1 - Rittweger, Jörn T1 - A novel optical approach for assessing in vivo bone segment deformation and its application in muscle-bone relationship studies in humans JF - Journal of Orthopaedic Translation Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.jot.2014.07.078 SN - 2214-0328 SN - 2214-031X VL - 2 IS - 4 SP - 238 EP - 238 PB - Elsevier CY - Singapore ER - TY - JOUR A1 - Xu, Jung-Ming A1 - Lü, Min A1 - Ma, Meijie A1 - Hellwig, Angelika T1 - Super connectivity of line graphs JF - Information processing letters Y1 - 2005 SN - 1872-6119 (E-Journal); 0020-0190 (Print) VL - Vol. 94 IS - Iss. 4 SP - 191 EP - 195 ER - TY - JOUR A1 - Wulfhorst, Helene A1 - Duwe, Anna-Maria A1 - Merseburg, Johannes A1 - Tippkötter, Nils T1 - Compositional analysis of pretreated (beech) wood using differential scanning calorimetry and multivariate data analysis JF - Tetrahedron N2 - The composition of plant biomass varies depending on the feedstock and pre-treatment conditions and influences its processing in biorefineries. In order to ensure optimal process conditions, the quantitative proportion of the main polymeric components of the pre-treated biomass has to be determined. Current standard procedures for biomass compositional analysis are complex, the measurements are afflicted with errors and therefore often not comparable. Hence, new powerful analytical methods are urgently required to characterize biomass. In this contribution, Differential Scanning Calorimetry (DSC) was applied in combination with multivariate data analysis (MVA) to detect the cellulose content of the plant biomass pretreated by Liquid Hot Water (LHW) and Organosolv processes under various conditions. Unlike conventional techniques, the developed analytic method enables the accurate quantification of monosaccharide content of the plant biomass without any previous sample preparation. It is easy to handle and avoids errors in sample preparation. Y1 - 2016 U6 - http://dx.doi.org/10.1016/j.tet.2016.04.029 VL - 72 IS - 46 SP - 7329 EP - 7334 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Wu, Chunsheng A1 - Poghossian, Arshak A1 - Bronder, Thomas A1 - Schöning, Michael Josef T1 - Sensing of double-stranded DNA molecules by their intrinsic molecular charge using the light-addressable potentiometric sensor JF - Sensors and Actuators B: Chemical N2 - A multi-spot light-addressable potentiometric sensor (LAPS), which belongs to the family of semiconductor field-effect devices, was applied for label-free detection of double-stranded deoxyribonucleic acid (dsDNA) molecules by their intrinsic molecular charge. To reduce the distance between the DNA charge and sensor surface and thus, to enhance the electrostatic coupling between the dsDNA molecules and the LAPS, the negatively charged dsDNA molecules were electrostatically adsorbed onto the gate surface of the LAPS covered with a positively charged weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)). The surface potential changes in each spot of the LAPS, induced by the layer-by-layer adsorption of a PAH/dsDNA bilayer, were recorded by means of photocurrent-voltage and constant-photocurrent measurements. In addition, the surface morphology of the gate surface before and after consecutive electrostatic adsorption of PAH and dsDNA layers was studied by atomic force microscopy measurements. Moreover, fluorescence microscopy was used to verify the successful adsorption of dsDNA molecules onto the PAH-modified LAPS surface. A high sensor signal of 25 mV was registered after adsorption of 10 nM dsDNA molecules. The lower detection limit is down to 0.1 nM dsDNA. The obtained results demonstrate that the PAH-modified LAPS device provides a convenient and rapid platform for the direct label-free electrical detection of in-solution hybridized dsDNA molecules. KW - Layer-by-layer adsorption KW - Poly(allylamine hydrochloride) KW - Label-free detection KW - DNA biosensor KW - LAPS KW - Field effect Y1 - 2016 U6 - http://dx.doi.org/10.1016/j.snb.2016.02.004 SN - 0925-4005 IS - 229 SP - 506 EP - 512 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Wu, Chunsheng A1 - Bronder, Thomas A1 - Poghossian, Arshak A1 - Werner, Frederik A1 - Schöning, Michael Josef T1 - Label-free detection of DNA using light-addressable potentiometric sensor modified with a positively charged polyelectrolyte layer JF - Nanoscale N2 - A multi-spot (16 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al–p-Si–SiO2 structure modified with a weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)) was applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. To achieve a preferentially flat orientation of DNA strands and thus, to reduce the distance between the DNA charge and MLAPS surface, the negatively charged probe single-stranded DNAs (ssDNA) were electrostatically adsorbed onto the positively charged PAH layer using a simple layer-by-layer (LbL) technique. In this way, more DNA charge can be positioned within the Debye length, yielding a higher sensor signal. The surface potential changes in each spot induced due to the surface modification steps (PAH adsorption, probe ssDNA immobilization, hybridization with complementary target DNA (cDNA), non-specific adsorption of mismatched ssDNA) were determined from the shifts of photocurrent–voltage curves along the voltage axis. A high sensor signal of 83 mV was registered after immobilization of probe ssDNA onto the PAH layer. The hybridization signal increases from 5 mV to 32 mV with increasing the concentration of cDNA from 0.1 nM to 5 μM. In contrast, a small signal of 5 mV was recorded in the case of non-specific adsorption of fully mismatched ssDNA (5 μM). The obtained results demonstrate the potential of the MLAPS in combination with the simple and rapid LbL immobilization technique as a promising platform for the future development of multi-spot light-addressable label-free DNA chips with direct electrical readout. Y1 - 2015 U6 - http://dx.doi.org/10.1039/C4NR07225A VL - 14 IS - 7 SP - 6143 EP - 6150 PB - Royal Society of Chemistry (RSC) CY - Cambridge ER - TY - JOUR A1 - Wu, Chunsheng A1 - Bronder, Thomas A1 - Poghossian, Arshak A1 - Werner, Frederik A1 - Bäcker, Matthias A1 - Schöning, Michael Josef T1 - Label-free electrical detection of DNA with a multi-spot LAPS: First step towards light-addressable DNA chips JF - Physica status solidi A : Applications and materials science N2 - A multi-spot (4 × 4 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al–p-Si–SiO2 structure has been applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. Single-stranded probe ssDNA molecules (20 bases) were covalently immobilized onto the silanized SiO2 gate surface. The unspecific adsorption of mismatch ssDNA on the MLAPS gate surface was blocked by bovine serum albumin molecules. To reduce the screening effect and to achieve a high sensor signal, the measurements were performed in a low ionic-strength solution. The photocurrent–voltage (I–V) curves were simultaneously recorded on all 16 spots after each surface functionalization step. Large shifts of I–V curves of 25 mV were registered after the DNA immobilization and hybridization event. In contrast, a small potential shift (∼5 mV) was observed in case of mismatch ssDNA, revealing good specificity of the sensor. The obtained results demonstrate the potential of the MLAPS as promising transducer platform for the multi-spot label-free electrical detection of DNA molecules by their intrinsic molecular charge. Y1 - 2014 U6 - http://dx.doi.org/10.1002/pssa.201330442 SN - 1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print) VL - 211 IS - 6 SP - 1423 EP - 1428 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Wrede, Oliver T1 - Mnemotechnik in graphischen Benutzeroberflächen JF - Form / Form-Diskurs : Zeitschrift für Design und Theorie. 1 (1996), H. 2 Y1 - 1996 ER - TY - JOUR A1 - Wrede, Oliver T1 - Wer nicht hören will muss sehen : ein Plädoyer für eine entwurfsbezogene Bildwissenschaft JF - Boxhorn. 12 (2005), H. Sehsturz Y1 - 2005 SP - 24 EP - 25 ER - TY - JOUR A1 - Wrede, Oliver T1 - Continuity in travel information JF - Information Design Journal N2 - This article discusses the contrast between the information transportation companies provide to travellers and that of their brand messaging. Companies’ brand messaging often portrays the service they provide as pleasant, stress free and perfect. Customers and users of the service, on the other hand, often describe their experience of the service as a negative one. This article suggests that the brand value would be greater if transportation companies paid more attention to the users’ experience when designing their information systems, particularly in worst case scenarios. Y1 - 2016 U6 - http://dx.doi.org/10.1075/idj.22.2.09wre SN - 0142-5471 N1 - Gedruckt vorhanden in der Bereichsbibliothek Boxgraben unter 53 Z 971-2016 (Magazin) VL - 22 IS - 2 SP - 172 EP - 178 PB - John Benjamins CY - Amsterdam ER - TY - JOUR A1 - Wosnitza, Franz T1 - Ein Testbarkeitsanalysemaß für den testfreundlichen Entwurf integrierter Schaltkreise auf Register-Transfer-Niveau JF - ITG-Fachberichte. 98 (1987) Y1 - 1987 N1 - ITG-Fachtagung vom 16. bis 18. März 1987 in Baden-Baden über Grossintegration SP - 291 EP - 295 ER - TY - JOUR A1 - Wollert, Jörg A1 - Vedral, Andreas A1 - Grimm, A. A1 - Holtmann, M. T1 - Bluetooth-Sicherheit : wie viel Persönlichkeit gebe ich preis? JF - Elektronik : Fachmedium für industrielle Anwender und Entwickler ; Sonderh. Wireless : Fachmedium für Entwicklungen funkbasierter Systeme Y1 - 2004 SN - 0013-5658 SN - 1611-5120 N1 - Printausg. in der Bibliothek vorhanden: 63 ZS 030; 23 Z 263 VL - Bd. 53 IS - Sonderh. März SP - 30 EP - 35 ER - TY - JOUR A1 - Wollert, Jörg A1 - Vedral, Andreas T1 - Einsatz von Open-Source-Software für Bluetooth-Evaluationsprototypen : Anwendungsempfehlungen und Einsatzbeispiele JF - Elektronik : Fachmedium für industrielle Anwender und Entwickler Y1 - 2002 SN - 0013-5658 N1 - Printausg. in der Bibliothek vorhanden: 63 ZS 030 VL - Bd. 51 IS - H. 22 SP - 70 EP - 73 ER - TY - JOUR A1 - Wollert, Jörg A1 - Leidinger, Rafael T1 - Automation trifft Automotive : SPS in der Fahrzeugtechnik JF - Elektronik automotive : Magazin für Entwicklungen in der Kfz-Elektronik und Telematik N2 - Eine SPS im Kraftfahrzeug? Das geht ja gar nicht – da gibt es doch all die Hersteller für Kfz-Steuergeräte, die konfigurierbare Hardware anbieten. Im Prinzip ja, aber leider sind gerade die Sensoren oder Aktoren nicht ansteuerbar, die der Entwickler genau für sein aktuelles Projekt benötigt. Dieser Beitrag gibt einen kleinen Einblick in neue Möglichkeiten des Rapid Prototyping für mechatronische Systeme auf der Basis von Speicherprogrammierbaren Steuerungen (SPS). Y1 - 2010 SN - 1614-0125 IS - 4/5 SP - 44 EP - 48 PB - WEKA Fachmedien CY - Haar ER - TY - JOUR A1 - Wollert, Jörg A1 - Kruse, Thomas A1 - Vedral, Andreas T1 - Die Kraft der drei Antennen : zuverlässige Funkkommunikation für die Automatisierungstechnik JF - Elektronik : Fachmedium für industrielle Anwender und Entwickler ; Sonderh. Wireless : Fachmedium für Entwicklungen funkbasierter Systeme Y1 - 2007 SN - 0013-5658; 1611-5120 N1 - Printausgabe in der Bibliothek vorhanden: 23 Z 133; 63 ZS 035 VL - 56 IS - Sonderh. 2 SP - 36 EP - 42 ER - TY - JOUR A1 - Wollert, Jörg A1 - Fiedler, Jörg T1 - atp-Marktanalyse Echtzeitbetriebssysteme JF - Automatisierungstechnische Praxis : atp ; Praxis der Meß-, Steuerungs-, Regelungs- und Informationstechnik mit Softwaretechnik Y1 - 1996 SN - 0340-4730 N1 - Printausg. in der Bibliothek vorhanden: 23 Z 324 VL - Bd. 38 IS - H. 1 SP - 33 EP - 44 ER - TY - JOUR A1 - Wollert, Jörg A1 - Fiedler, J. A1 - Stockmann, T. T1 - Automatisieren mit dem PC : was der Personal Computer kann und wo er passen muss JF - Elektronik : Fachmedium für industrielle Anwender und Entwickler Y1 - 1994 SN - 0013-5658 IS - Nr. 6 SP - 76 EP - 82 ER - TY - JOUR A1 - Wollert, Jörg A1 - Buda, Aurel T1 - Funklösungen im parallelen Betrieb JF - Intelligenter produzieren : die Wissensplattform für das technische Management Y1 - 2009 SN - 1869-2745 IS - H. 4 SP - 6 EP - 8 PB - VDMA-Verl. CY - Frankfurt, M. ER - TY - JOUR A1 - Wollert, Jörg A1 - Booke, Andreas T1 - IoT von der Stange JF - elektronik N2 - Heute sollte am besten jedes Gerät in die große Rechnerwolke eingebettet werden. Doch so einfach ist das nicht, denn Cloud ist viel mehr als nur das Internet der Dinge. Als Anwender muss man sich also fragen, welche Dienste man möchte und welchem Anbieter man sein Vertrauen schenkt. KW - Einbetten in das Internet der Dinge Y1 - 2016 IS - 21 (2016) SP - 30 EP - 37 PB - WEKA-Fachmedien CY - München ER - TY - JOUR A1 - Wollert, Jörg T1 - Funkstandards für Sensornetzwerke JF - Elektronik : Fachmedium für industrielle Anwender und Entwickler Y1 - 2014 SN - 0013-5658 VL - Bd. 63 IS - H. 12 SP - 36 EP - 41 PB - WEKA-Fachmedien CY - Haar ER - TY - JOUR A1 - Wollert, Jörg T1 - Echtzeit-Ethernet : Protokoll-Reigen JF - Elektronik : Fachmedium für industrielle Anwender und Entwickler Y1 - 2014 SN - 0013-5658 VL - Bd. 63 IS - H. 26 SP - 24 EP - 31 PB - WEKA-Fachmedien CY - Haar ER - TY - JOUR A1 - Wollert, Jörg T1 - Der Embedded Wireless-Report JF - Elektronik : Fachmedium für industrielle Anwender und Entwickler ; Sonderh. Wireless : Fachmedium für Entwicklungen funkbasierter Systeme Y1 - 2014 SN - 0013-5658 SP - 18 EP - 25 PB - WEKA-Fachmedien CY - Haar ER - TY - JOUR A1 - Wollert, Jörg T1 - Echtzeit-Ethernet mit Standardtechnik JF - Elektronik : Fachmedium für industrielle Anwender und Entwickler ; Sonderh. Embedded : Fachmagazin für die Entwicklung von Embedded-Systemen Y1 - 2014 SN - 0013-5658 VL - Bd. 63 IS - H. 12 SP - 28 EP - 32 PB - WEKA-Fachmedien CY - Haar ER - TY - JOUR A1 - Wollert, Jörg T1 - Im Sog des Standards : Windows CE als Betriebssystem für Embedded Controller JF - Elektronik : Fachmedium für industrielle Anwender und Entwickler Y1 - 1998 SN - 0013-5658 N1 - Printausg. in der Bibliothek vorhanden: 63 ZS 030 VL - Bd. 47 IS - H. 9 SP - 40 EP - 51 ER -