TY - JOUR A1 - Öhlschläger, Peter A1 - Pes, Michaela A1 - Osen, Wolfram A1 - Dürst, Matthias T1 - An improved rearranged Human Papillomavirus Type 16 E7 DNA vaccine candidate (HPV-16 E7SH) induces an E7 wildtype-specific T cell response / Öhlschläger, Peter ; Pes, Michaela ; Osen, Wolfram ; Dürst, Matthias ; Schneider, Achim ; Gissmann, Lutz ; Kaufman JF - Vaccine. 24 (2006), H. 15 Y1 - 2006 SN - 0264-410X SP - 2880 EP - 2893 ER - TY - JOUR A1 - Yoshinobu, Tatsuo A1 - Moritz, Werner A1 - Finger, Friedhelm A1 - Schöning, Michael Josef ED - Comini, Elisabetta T1 - Application of thin-film amorphous silicon to chemical imaging JF - Nanostructured materials and hybrid composites for gas sensors and biomedical applications : symposium held April 18-20, 2006, San Francisco , California, U.S.A. Y1 - 2006 SN - 9781558998711 N1 - Materials Research Society symposia proceedings; v. 915 IS - Paper 0910-A-20-01 SP - 1 EP - 10 ER - TY - JOUR A1 - Weber, Hans-Joachim A1 - Mo, Xiumei A1 - Ramakrishna, S. T1 - PCL-PGLA composite tubular scaffold preparation and biocompatibility investigation / X. Mo, H.-J. Weber, S. Ramakrishna JF - The International journal of artificial organs. 29 (2006), H. 8 Y1 - 2006 SP - 790 EP - 799 PB - - ER - TY - CHAP A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Preface of the Special Issue of I3S 2005 in Jülich (Germany) N2 - International Symposium on Sensor Science, I3S 2005 <3; 2005; Juelich, Germany> In: Sensors 2006, 6, 260-261 ISSN 1424-8220 KW - Biosensor KW - I3S 2005 KW - International Symposium on Sensor Science Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1365 ER - TY - JOUR A1 - Wagner, Torsten A1 - Rao, C. A1 - Kloock, Joachim P. A1 - Yoshinobu, T. A1 - Otto, R. A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - “LAPS Card”—A novel chip card-based light-addressable potentiometric sensor (LAPS) JF - Sensors and Actuators B: Chemical. 118 (2006), H. 1-2 Y1 - 2006 SN - 0925-4005 N1 - Eurosensors XIX - Eurosensors XIX - The 19th European Conference on Solid-State Transducers SP - 33 EP - 40 ER - TY - CHAP A1 - Wagner, Thorsten A1 - Kohl, Claus-Dieter A1 - Fröba, Michael A1 - Tiemann, Michael T1 - Gas sensing properties of ordered mesoporous SnO2 N2 - We report on the synthesis and CO gas-sensing properties of mesoporous tin(IV) oxides (SnO2). For the synthesis cetyltrimethylammonium bromide (CTABr) was used as a structure-directing agent; the resulting SnO2 powders were applied as films to commercially available sensor substrates by drop coating. Nitrogen physisorption shows specific surface areas up to 160 m2·g-1 and mean pore diameters of about 4 nm, as verified by TEM. The film conductance was measured in dependence on the CO concentration in humid synthetic air at a constant temperature of 300 °C. The sensors show a high sensitivity at low CO concentrations and turn out to be largely insensitive towards changes in the relative humidity. We compare the materials with commercially available SnO2-based sensors. KW - Biosensor KW - Tin oxide KW - sensing properties KW - CO KW - humidity Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1422 ER - TY - JOUR A1 - Vorst, Phillip A1 - Ferrein, Alexander A1 - Lakemeyer, Gerhard T1 - AllemaniACs3D team description Y1 - 2006 SP - 1 EP - 6 ER - TY - CHAP A1 - Vedral, Andreas A1 - Wollert, Jörg A1 - Buda, A. A1 - Altrock, R. T1 - The capability of bluetooth for real-time transmission in automation T2 - Proceedings of the IASTED International Conference on Networks and Communication Systems 2006 : March 29 - 31, 2006, Chiang Mai, Thailand Y1 - 2006 SP - 168 EP - 175 PB - Acta Pr. CY - Anaheim, Calif. ER - TY - CHAP A1 - Uibel, Thomas A1 - Blaß, Hans Joachim T1 - Load Carrying Capacity of Joints with Dowel Type Fasteners in Solid Wood Panels T2 - Proceedings. CIB-W18 Meeting 2006, Florence, Italy 2006 Y1 - 2006 SN - 0945-6996 N1 - Paper 39-7-5 SP - 1 EP - 10 ER - TY - CHAP A1 - Tymecki, Lukasz A1 - Glab, Stanislaw A1 - Koncki, Robert T1 - Miniaturized, planar ion-selective electrodes fabricated by means of thick-film technology N2 - Various planar technologies are employed for developing solid-state sensors having low cost, small size and high reproducibility; thin- and thick-film technologies are most suitable for such productions. Screen-printing is especially suitable due to its simplicity, low-cost, high reproducibility and efficiency in large-scale production. This technology enables the deposition of a thick layer and allows precise pattern control. Moreover, this is a highly economic technology, saving large amounts of the used inks. In the course of repetitions of the film-deposition procedure there is no waste of material due to additivity of this thick-film technology. Finally, the thick films can be easily and quickly deposited on inexpensive substrates. In this contribution, thick-film ion-selective electrodes based on ionophores as well as crystalline ion-selective materials dedicated for potentiometric measurements are demonstrated. Analytical parameters of these sensors are comparable with those reported for conventional potentiometric electrodes. All mentioned thick-film strip electrodes have been totally fabricated in only one, fully automated thickfilm technology, without any additional manual, chemical or electrochemical steps. In all cases simple, inexpensive, commercially available materials, i.e. flexible, plastic substrates and easily cured polymer-based pastes were used. KW - Biosensor KW - Potentiometry KW - thick-film technology KW - screen-printing KW - ion-selective electrodes Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1506 ER - TY - JOUR A1 - Sukhotina, Irina A1 - Streckert, Joachim R. A1 - Bitz, Andreas A1 - Hansen, Volkert W. A1 - Lerchl, Alexander T1 - 1800 MHz electromagnetic field effects on melatonin release from isolated pineal glands JF - Journal of Pineal Research Y1 - 2006 U6 - http://dx.doi.org/10.1111/j.1600-079X.2005.00284.x SN - 1600-079X VL - 40 IS - 1 SP - 86 EP - 91 ER - TY - JOUR A1 - Streun, M. A1 - Chavan, U. A1 - Lame, H. A1 - Parl, C. A1 - Müller-Veggian, Mattea A1 - Ziemons, Karl T1 - Treating the Gain Non-Uniformity of Multi Channel PMTs by Channel-Specific Trigger Levels JF - 2006 IEEE Nuclear Science Symposium Conference Record, Vol. 2. Y1 - 2006 SN - 1082-3654 SP - 1301 EP - 1304 CY - San Diego, CA ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - The data acquisition system of ClearPET neuro - a small animal PET scanner JF - IEEE Transactions on Nuclear Science N2 - The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jülich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 3 SP - 700 EP - 703 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - Timemark correction for the ClearPET™ scanners JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented Y1 - 2006 SN - 1082-3654 SP - 2057 EP - 2060 ER - TY - JOUR A1 - Stanley, Lesley A. A1 - Horsburgh, Brian C. A1 - Ross, Jillian A1 - Scheer, Nico A1 - Wolf, C. Roland T1 - Nuclear Receptors which play a pivotal role in drug disposition and chemical toxicity JF - Drug Metabolism Reviews Y1 - 2006 U6 - http://dx.doi.org/10.1080/03602530600786232 SN - 1097-9883 VL - 38 IS - 3 SP - 515 EP - 597 ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Khoi Duc T1 - Limit loads of circumferentially flawed pipes and cylindrical vessels under internal pressure JF - International Journal of Pressure Vessels and Piping. 83 (2006), H. 3 Y1 - 2006 SN - 0308-0161 SP - 188 EP - 196 ER - TY - GEN A1 - Staat, Manfred A1 - Barry, Steve T1 - Continuum Mechanics with an Introduction to the Finite Element Method / Steve Barry; Manfred Staat. With extensions by Manfred Staat. N2 - Contents: 1 Introduction 2 One Dimensional Continuum Mechanics 3 Tensors 4 Three Dimensional Stress and Strain 5 Conservation Laws 6 Contiunuum Modelling 7 Plain Problems 8 Questions 9 Reference Information KW - Technische Mechanik KW - Finite-Elemente-Methode Y1 - 2006 ER - TY - GEN A1 - Staat, Manfred T1 - Engineering Mechanics. Lecture Notes. 2nd edition, translation of the 3rd corrected and extended German edition of "Technische Mechanik" N2 - English translation of the corrected lectures notes of Sebastian Krämer. Contents 0 Introduction to Mechanics 1 Statics of Rigid Bodies 2 Elastostatics (Strength of Materials) 3 Kinematics 4 Kinetics Literature KW - Technische Mechanik KW - Mechanics KW - Statics KW - Elastostatics KW - Kinematics KW - Kinetics Y1 - 2006 ER - TY - CHAP A1 - Staat, Manfred T1 - Problems and chances for probabilistic fracture mechanics in the analysis of steel pressure boundary reliability. - Überarb. Ausg. N2 - In: Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994. - Vienna , 1996. - Seite: 43 - 55 IAEA-TECDOC-920 Abstract: It is shown that the difficulty for probabilistic fracture mechanics (PFM) is the general problem of the high reliability of a small population. There is no way around the problem as yet. Therefore what PFM can contribute to the reliability of steel pressure boundaries is demon­strated with the example of a typical reactor pressure vessel and critically discussed. Although no method is distinguishable that could give exact failure probabilities, PFM has several addi­tional chances. Upper limits for failure probability may be obtained together with trends for design and operating conditions. Further, PFM can identify the most sensitive parameters, improved control of which would increase reliability. Thus PFM should play a vital role in the analysis of steel pressure boundaries despite all shortcomings. KW - Bruchmechanik KW - probabilistic fracture mechanics KW - PFM Y1 - 2006 ER - TY - CHAP A1 - Srivastava, Alok A1 - Singh, Virendra A1 - Dhand, Chetna A1 - Kaur, Manindar A1 - Singh, Tejvir A1 - Witte, Katrin A1 - Scherer, Ulrich W. T1 - Study of swift heavy ion modified conduction polymer composites for application as gas sensor N2 - A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas. KW - Biosensor KW - Conducing polymer KW - ammonia gas sensors KW - swift heavy ions KW - polymer composites Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1345 ER - TY - CHAP A1 - Spannhake, Jan A1 - Schulz, Olaf A1 - Helwig, Andreas A1 - Krenkow, Angelika A1 - Müller, Gerhard A1 - Doll, Theodor T1 - High-temperature MEMS heater platforms: long-term performance of metal and semiconductor heater materials N2 - Micromachined thermal heater platforms offer low electrical power consumption and high modulation speed, i.e. properties which are advantageous for realizing nondispersive infrared (NDIR) gas- and liquid monitoring systems. In this paper, we report on investigations on silicon-on-insulator (SOI) based infrared (IR) emitter devices heated by employing different kinds of metallic and semiconductor heater materials. Our results clearly reveal the superior high-temperature performance of semiconductor over metallic heater materials. Long-term stable emitter operation in the vicinity of 1300 K could be attained using heavily antimony-doped tin dioxide (SnO2:Sb) heater elements. KW - Biosensor KW - Hotplate KW - heater metallisation KW - high-temperature stability KW - electro-migration KW - doped silicon KW - doped metal oxide KW - antimony doped tin oxide Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1513 ER - TY - JOUR A1 - Selmer, Thorsten A1 - Yu, Lihua A1 - Blaser, Martin A1 - Andrei, Paula I. T1 - 4-Hydroxyphenylacetate decarboxylases: properties of a novel subclass of glycyl radical enzyme systems / Yu, L. ; Blaser, M. ; Andrei, PI. ; Pierik, AJ. Selmer, T. JF - Biochemistry. 31 (2006), H. 45 Y1 - 2006 N1 - PMID: 16878993 SP - 9584 EP - 9592 ER - TY - JOUR A1 - Selmer, Thorsten A1 - Kim, Jihoe A1 - Darley, Daniel A1 - Buckel, Wolfgang T1 - Characterization of (R)-2-hydroxyisocaproate dehydrogenase and a family III coenzyme A transferase involved in reduction of L-leucine to isocaproate by Clostridium difficile / Kim, J. ; Darley, D. ; Selmer, T. ; Buckel, W. JF - Applied and Environmental Microbiology. 72 (2006), H. 9 Y1 - 2006 SN - 0099-2240 N1 - PMID: 16957230 SP - 6062 EP - 6069 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - BioFEDs (field-effect devices) : State-of-the-art and new directions JF - Electroanalysis Y1 - 2006 U6 - http://dx.doi.org/10.1002/elan.200603609 SN - 1521-4109 VL - 18 IS - 19-20 SP - 1893 EP - 1900 ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Abouzar, Maryam H. A1 - Wagner, Torsten A1 - Näther, Niko A1 - Rolka, David A1 - Yoshinobu, Tatsuo A1 - Kloock, Joachim P. A1 - Turek, Monika A1 - Ingebrandt, Sven A1 - Poghossian, Arshak T1 - A semiconductor-based field-effect platform for (bio-)chemical and physical sensors: From capacitive EIS sensors and LAPS over ISFETs to nano-scale devices T2 - MRS Proceedings Y1 - 2006 U6 - http://dx.doi.org/10.1557/PROC-0952-F08-02 N1 - Vol. 952 - Symposium F - Integrated Nanosensors SP - 1 EP - 9 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Abouzar, Maryam H. A1 - Ingebrandt, Sven A1 - Platen, Johannes A1 - Offenhäusser, Andreas A1 - Poghossian, Arshak ED - Comini, Elisabetta T1 - Towards label-free detection of charged macromolecules using field-effect-based structures : Scaling down from capacitive EIS sensor over ISFET to nano-scale devices JF - Nanostructured materials and hybrid composites for gas sensors and biomedical applications : symposium held April 18-20, 2006, San Francisco , California, U.S.A. Y1 - 2006 SN - 9781558998711 IS - paper 0915-R05-04 SP - 89 EP - 94 ER - TY - JOUR A1 - Schleser, Markus A1 - Walk-Lauffer, Bernd A1 - Raupach, Michael A1 - Dilthey, Ulrich T1 - Application of polymers for textile-reinforced concrete JF - Journal of materials in civil engineering : properties, applications, durability Y1 - 2006 SN - 0899-1561 VL - 18 IS - 5 SP - 670 EP - 676 ER - TY - JOUR A1 - Scherer, Ulrich W. A1 - Srivastava, Alok A1 - Singh, Vivendra A1 - Chandra, Amita T1 - Electrical conductivity studies of swift heavy ion modified PVC and PVC-PANI composite / Alok Srivastava ,Virendra Singh, Amita Chandra, K.Witte, U.W.Scherer and T.V.Singh JF - Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 245 (2006), H. 1 Y1 - 2006 SN - 0168-583X SP - 277 EP - 280 ER - TY - JOUR A1 - Scherer, Ulrich W. T1 - Controlled ion track etching / J. George; M. Irkens ; S. Neumann ; U. W. Scherer ; A. Srivastava ; D. Sinha ; D. Fink JF - Radiation Effects and Defects in Solids. 161 (2006), H. 3 Y1 - 2006 SP - 161 EP - 175 ER - TY - CHAP A1 - Sakthivel, Mariappan A1 - Weppner, Werner T1 - Response behaviour of a hydrogen sensor based on ionic conducting polymer-metal interfaces prepared by the chemical reduction method N2 - A solid-state amperometric hydrogen sensor based on a protonated Nafion membrane and catalytic active electrode operating at room temperature was fabricated and tested. Ionic conducting polymer-metal electrode interfaces were prepared chemically by using the impregnation-reduction method. The polymer membrane was impregnated with tetra-ammine platinum chloride hydrate and the metal ions were subsequently reduced by using either sodium tetrahydroborate or potassium tetrahydroborate. The hydrogen sensing characteristics with air as reference gas is reported. The sensors were capable of detecting hydrogen concentrations from 10 ppm to 10% in nitrogen. The response time was in the range of 10-30 s and a stable linear current output was observed. The thin Pt films were characterized by XRD, Infrared Spectroscopy, Optical Microscopy, Atomic Force Microscopy, Scanning Electron Microscopy and EDAX. KW - Biosensor KW - Hydrogen sensor KW - amperometric sensor KW - porous Pt electrode KW - chemical reduction method Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1399 ER - TY - JOUR A1 - Ritz, Thomas A1 - Stender, Michael T1 - Modeling of B2B mobile commerce processes JF - International Journal of Production Economics Y1 - 2006 U6 - http://dx.doi.org/10.1016/j.ijpe.2005.05.017 SN - 0925-5273 VL - 101 IS - 1 SP - 128 EP - 139 ER - TY - JOUR A1 - Reugels, Alexander M. A1 - Boggetti, Barbara A1 - Scheer, Nico A1 - Campos-Ortega, José A. T1 - Asymmetric localization of Numb:EGFP in dividing neuroepithelial cells during neurulation in Danio rerio JF - Developmental Dynamics Y1 - 2006 U6 - http://dx.doi.org/10.1002/dvdy.20699 SN - 1097-0177 VL - 235 IS - 4 SP - 934 EP - 948 ER - TY - CHAP A1 - Reimer, Lars A1 - Braun, Carsten A1 - Ballmann, Josef T1 - Analysis of the static and dynamic aero-structural response of an elastic swept wing model by direct aeroelastic simulation T2 - ICAS 2006 proceedings : 25th Congress of the International Council of the Aeronautical Sciences ; Hamburg, Germany, 3 - 8 September, 2006 : 25th International Congress of Aeronautical Sciences Y1 - 2006 SN - 0-9533991-7-6 SP - Paper No. 2006-10.3.3 PB - Optimage CY - Edinburgh ER - TY - CHAP A1 - Raupach, Michael A1 - Orlowsky, Jeannette A1 - Büttner, T. A1 - Dilthey, Ulrich A1 - Schleser, Markus ED - Hegger, Josef T1 - Epoxy-impregnated textiles in concrete - load bearing capacity and durability T2 - Textile reinforced concrete : proceedings of the 1. International RILEM Conference, held at the RWTH Aachen, September 6/7, 2006. (RILEM proceedings ; 50) Y1 - 2006 SN - 2-912143-97-7 SP - 77 EP - 88 PB - RILEM Publ. CY - Bagneux ER - TY - CHAP A1 - Rabner, Arthur A1 - Shacham, Yosi T1 - A concept for a sensitive micro total analysis system for high throughput fluorescence imaging N2 - This paper discusses possible methods for on-chip fluorescent imaging for integrated bio-sensors. The integration of optical and electro-optical accessories, according to suggested methods, can improve the performance of fluorescence imaging. It can boost the signal to background ratio by a few orders of magnitudes in comparison to conventional discrete setups. The methods that are present in this paper are oriented towards building reproducible arrays for high-throughput micro total analysis systems (µTAS). The first method relates to side illumination of the fluorescent material placed into microcompartments of the lab-on-chip. Its significance is in high utilization of excitation energy for low concentration of fluorescent material. The utilization of a transparent µLED chip, for the second method, allows the placement of the excitation light sources on the same optical axis with emission detector, such that the excitation and emission rays are directed controversly. The third method presents a spatial filtering of the excitation background. KW - Biosensor KW - Fluorescence KW - imaging KW - lab-on-chip KW - fluidic KW - lenslet array KW - LED chip KW - image sensor KW - biosensor Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1456 ER - TY - CHAP A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Silicon-based chemical and biological field-effect sensors T2 - Encyclopedia of Sensors. Vol. 9 S - Sk Y1 - 2006 SN - 1-58883-065-9 SP - 463 EP - 534 PB - ASP, American Scientific Publ. CY - Stevenson Ranch, Calif. ER - TY - CHAP A1 - Poghossian, Arshak A1 - Schumacher, Kerstin A1 - Kloock, Joachim P. A1 - Rosenkranz, Christian A1 - Schultze, Joachim W. A1 - Müller-Veggian, Mattea A1 - Schöning, Michael Josef T1 - Functional testing and characterisation of ISFETs on wafer level by means of a micro-droplet cell N2 - A wafer-level functionality testing and characterisation system for ISFETs (ionsensitive field-effect transistor) is realised by means of integration of a specifically designed capillary electrochemical micro-droplet cell into a commercial wafer prober-station. The developed system allows the identification and selection of “good” ISFETs at the earliest stage and to avoid expensive bonding, encapsulation and packaging processes for nonfunctioning ISFETs and thus, to decrease costs, which are wasted for bad dies. The developed system is also feasible for wafer-level characterisation of ISFETs in terms of sensitivity, hysteresis and response time. Additionally, the system might be also utilised for wafer-level testing of further electrochemical sensors. KW - Biosensor KW - Biosensorik KW - ISFET KW - Wafer KW - ISFET KW - wafer-level testing KW - capillary micro-droplet cell Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1259 ER - TY - CHAP A1 - Poghossian, Arshak A1 - Ingebrandt, S. A1 - Platen, J. A1 - Schöning, Michael Josef T1 - Field-effect sensors with charged macromolecules – from micro towards nano aspects T2 - Biochemical Sensing Utilisation of Micro-and Nanotechnologies, Warschau, Nov. 2005 : Lecture Notes of the ICB Seminar / ed.: M. Mascini, W. Torbicz Y1 - 2006 SP - 74 EP - 81 PB - Polish Academy Sciences Press CY - Warsaw ER - TY - JOUR A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Sakkari, M. A1 - Kassab, T. A1 - Han, Y. A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Field-effect sensors for monitoring the layer-by-layer adsorption of charged macromolecules JF - Sensors and Actuators B: Chemical. 118 (2006), H. 1-2 Y1 - 2006 SN - 0925-4005 N1 - Eurosensors XIX - Eurosensors XIX - The 19th European Conference on Solid-State Transducers SP - 163 EP - 170 ER - TY - JOUR A1 - Plum, Leona A1 - Ma, Xiaosong A1 - Hampel, Brigitte A1 - Balthasar, Nina A1 - Coppari, Roberto A1 - Münzberg, Heike A1 - Shanabrough, Marya A1 - Burdakov, Denis A1 - Rother, Eva A1 - Janoschek, Ruth A1 - Alber, Jens A1 - Belgardt, Bengt F. A1 - Koch, Linda A1 - Seibler, Jost A1 - Schenk, Frieder A1 - Fekete, Csaba A1 - Suzuki, Akira A1 - Mak, Tak W. A1 - Krone, Wilhelm A1 - Horvath, Tamas L. A1 - Ashcroft, Frances M. A1 - Brüning, Jens C. T1 - Enhanced PIP3 signaling in POMC neurons causes KATP channel activation and leads to diet-sensitive obesity JF - The Journal of Clinical Investigation (JCI) Y1 - 2006 U6 - http://dx.doi.org/10.1172/JCI27123 SN - 1558-8238 VL - 116 IS - 7 SP - 1886 EP - 1901 ER - TY - CHAP A1 - Platen, Johannes A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Microstructured Nanostructures – nanostructuring by means of conventional photolithography and layer-expansion technique N2 - A new and simple method for nanostructuring using conventional photolithography and layer expansion or pattern-size reduction technique is presented, which can further be applied for the fabrication of different nanostructures and nano-devices. The method is based on the conversion of a photolithographically patterned metal layer to a metal-oxide mask with improved pattern-size resolution using thermal oxidation. With this technique, the pattern size can be scaled down to several nanometer dimensions. The proposed method is experimentally demonstrated by preparing nanostructures with different configurations and layouts, like circles, rectangles, trapezoids, “fluidic-channel”-, “cantilever”- and meander-type structures. KW - Biosensor KW - Nanostructuring KW - layer expansion KW - pattern-size reduction KW - self-aligned patterning Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1477 ER - TY - CHAP A1 - Pijanowska, Dorota G. A1 - Remiszewska, Elzbieta A1 - Pederzolli, Cecilia A1 - Lunelli, Lorenzo A1 - Vendano, Michele A1 - Canteri, Roberto A1 - Dudzinski, Konrad A1 - Kruk, Jerzy A1 - Torbicz, Wladyslaw T1 - Surface modification for microreactor fabrication N2 - In this paper, methods of surface modification of different supports, i.e. glass and polymeric beads for enzyme immobilisation are described. The developed method of enzyme immobilisation is based on Schiff’s base formation between the amino groups on the enzyme surface and the aldehyde groups on the chemically modified surface of the supports. The surface of silicon modified by APTS and GOPS with immobilised enzyme was characterised by atomic force microscopy (AFM), time-of-flight secondary ion mass spectroscopy (ToF-SIMS) and infrared spectroscopy (FTIR). The supports with immobilised enzyme (urease) were also tested in combination with microreactors fabricated in silicon and Perspex, operating in a flow-through system. For microreactors filled with urease immobilised on glass beads (Sigma) and on polymeric beads (PAN), a very high and stable signal (pH change) was obtained. The developed method of urease immobilisation can be stated to be very effective. KW - Biosensor KW - Microreactors KW - surface modification KW - enzyme immobilisation KW - lab-on-a-chip Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1480 ER - TY - CHAP A1 - Pijanowska, Dorota G. A1 - Remiszewska, Elzbieta T1 - pH-based detection of phenylalnine by potentiometric and colorimetric methods N2 - In this paper, methods of sample preparation for potentiometric measurement of phenylalanine are presented. Basing on the spectrophotometric measurements of phenylalanine, the concentrations of reagents of the enzymatic reaction (10 mM L-Phe, 0,4 mM NAD+, 2U L-PheDH) were determined. Then, the absorption spectrum of the reaction product, NADH, was monitored (maximum peak at 340 nm). The results obtained by the spectrophotometric method were compared with the results obtained by the colourimetry, using pH indicators. The above-mentioned two methods will be used as references for potentiometric measurements of phenylalanine concentration. KW - Biosensor KW - Phenylalanine determination KW - enzymatic methods KW - pH-based biosensing Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1536 ER - TY - CHAP A1 - Pietsch, Wolfram A1 - Herzwurm, Georg A1 - Zander, Dietmar T1 - Assuring quality of QFD-education in Germany T2 - ISQFD'06: 12th International Symposium on QFD : Tokyo, 07.-09.2006 Y1 - 2006 SP - 1 EP - 6 ER - TY - CHAP A1 - Pfaff, Raphael A1 - Vinsonneau, B. A1 - Burnham, K. J. T1 - Multiple models for nonlinear systems T2 - Proceedings / Eigteenth International Conference on Systems Engineering : ICSE 2006 : 5 - 7 September 2006 ; [held at Coventry University, UK] Y1 - 2006 SN - 1-84600-013-0 SP - 347 EP - 352 ER - TY - THES A1 - Pfaff, Raphael T1 - Modelling of nonlinear systems using piecewise defined models Y1 - 2006 N1 - Coventry, Univ., Masterarbeit, 2006 ER - TY - CHAP A1 - Pak, Daniel A1 - Piegeler, D. A1 - Feldmann, Markus A1 - Schleser, Markus A1 - Dilthey, Ulrich ED - Hegger, Josef T1 - Hybrid joints of textile reinforced concrete parts - designed for assembly T2 - Textile reinforced concrete : proceedings of the 1. International RILEM Conference, held at the RWTH Aachen, September 6/7, 2006. (RILEM proceedings ; 50) Y1 - 2006 SN - 2-912143-97-7 SP - 181 EP - 190 PB - RILEM Publ. CY - Bagneux ER - TY - CHAP A1 - Näther, Niko A1 - Poghossian, Arshak A1 - Platen, J. A1 - Yoshinobu, T. A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - Multi-parameter sensing of both physical and (bio-)chemical quantities using the same transducer principle T2 - Biochemical sensing utilisation of micro- and nanotechnologies : Warsaw, [23rd - 26th] November 2005 / ed. by M. Mascini ... Y1 - 2006 SP - 172 EP - 181 CY - Warsaw ER - TY - CHAP A1 - Näther, Niko A1 - Juárez, Leon M. A1 - Emmerich, Rüdiger A1 - Berger, Jörg A1 - Friedrich, Peter A1 - Schöning, Michael Josef T1 - Detection of hydrogen peroxide (H2O2) at exposed temperatures for industrial processes N2 - An H2O2 sensor for the application in industrial sterilisation processes has been developed. Therefore, automated sterilisation equipment at laboratory scale has been constructed using parts from industrial sterilisation facilities. In addition, a software tool has been developed for the control of the sterilisation equipment at laboratory scale. First measurements with the developed sensor set-up as part of the sterilisation equipment have been performed and the sensor has been physically characterised by optical microscopy and SEM. KW - Biosensor KW - Gas sensor KW - hydrogen peroxide KW - sterilisation KW - catalytic decomposition Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1418 ER - TY - JOUR A1 - Näther, Niko A1 - Emmerich, Rüdiger A1 - Berger, Jörg A1 - Friedrich, Peter A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schöning, Michael Josef T1 - A novel gas-phase hydrogen peroxide sensor basing on a combined physical/chemical transduction mechanism JF - Nanofunctional materials, nanostructures, and novel devices for biological and chemical detection : November 27 - December 1, 2006, Boston, Massachusetts, USA ; [at the 2006 MRS Fall Meeting]. Y1 - 2006 SN - 978-1-60423-407-7 N1 - Materials Research Society symposium proceedings ; 951 ; MRS fall meeting ; (2006.11.27-12.01 : ; Boston, Mass.) SP - 63 EP - 68 PB - Materials Research Soc. CY - Warrendale, Pa. ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Moro, D. A1 - Ferreti, A. A1 - Colautti, P. T1 - The new articulated twin mini TEPC JF - Annual Report 2006 / Istituto Nazionale di Fisica Nucleare / Laboratori Nazionali Y1 - 2006 SP - 273 CY - Legnaro ER - TY - JOUR A1 - Mottaghy, Darius A1 - Rath, Volker T1 - Latent heat effects in subsurface heat transport modelling and their impact on palaeotemperature reconstructions JF - Geophysical Journal International Y1 - 2006 U6 - http://dx.doi.org/10.1111/j.1365-246X.2005.02843.x SN - 1365-246X VL - 164 IS - 1 SP - 236 EP - 245 ER - TY - JOUR A1 - Mosset, J.-B. A1 - Devroede, O. A1 - Krieguer, M. A1 - Rey, M. A1 - Vieira, J.-M. A1 - Jung, J. H. A1 - Kuntner, C. A1 - Streun, M. A1 - Ziemons, Karl A1 - Auffray, E. A1 - Sempere-Roldan, P. A1 - Lecoq, P. A1 - Bruyndonckx, P. A1 - Loude, J.-F. A1 - Tavernier, S. A1 - Morcel, C. T1 - Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator JF - IEEE Transactions on Nuclear Science N2 - This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 1 SP - 25 EP - 29 ER - TY - CHAP A1 - Moreno, Lia A1 - Dosev, D. A1 - Bratov, A. A1 - Dominguez, C. A1 - Schöning, Michael Josef A1 - Kloock, Joachim P. T1 - Effect of electrical properties of the surrounding medium on the response of an interdigitated electrode array with chalcogenide glass film T2 - XX Eurosensors : 20th anniversary ; Göteborg, Sweden, 17 - 20 September 2006 ; [proceedings]. - Vol. 1 Y1 - 2006 SN - 978-91-631-9280-7 N1 - Paper number: T1A-P22 SP - 384 EP - 385 CY - Göteborg ER - TY - JOUR A1 - Mistler, Michael A1 - Butenweg, Christoph A1 - Meskouris, Konstantin T1 - Modelling methods of historic masonry buildings under seismic excitation JF - Journal of seismology Y1 - 2006 U6 - http://dx.doi.org/10.1007/s10950-006-9033-z SN - 1383-4649 (Print) ; 1573-157X (E-Journal) VL - Volume 10 IS - No. 4 SP - 497 EP - 510 ER - TY - CHAP A1 - Mirmohseni, Abdolreza A1 - Rostamizadeh, Kobra T1 - Quartz crystal nanobalance in conjunction with principal component analysis for identification of volatile organic compounds N2 - Quartz crystal nanobalance (QCN) sensors are considered as powerful masssensitive sensors to determine materials in the sub-nanogram level. In this study, a single piezoelectric quartz crystal nanobalance modified with polystyrene was employed to detect benzene, toluene, ethylbenzene and xylene (BTEX compounds). The frequency shift of the QCN sensor was found to be linear against the BTEX compound concentrations in the range about 1-45 mg l-1. The correlation coefficients for benzene, toluene, ethylbenzene, and xylene were 0.991, 0.9977, 0.9946 and 0.9971, respectively. The principal component analysis was also utilized to process the frequency response data of the single piezoelectric crystal at different times, considering to the different adsorption-desorption dynamics of BTEX compounds. Using principal component analysis, it was found that over 90% of the data variance could still be explained by use of two principal components (PC1 and PC2). Subsequently, the successful identification of benzene and toluene was possible through the principal component analysis of the transient responses of the polystyrene modified QCN sensor. The results showed that the polystyrene-modified QCN had favorable identification and quantification performances for the BTEX compounds. KW - Biosensor KW - Quartz crystal nanobalance (QCN) KW - BTEX compounds KW - principal component Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1434 ER - TY - CHAP A1 - Merten, Sabine A1 - Conrad, Thorsten A1 - Kämper, Klaus-Peter A1 - Picard, Antoni A1 - Schütze, Andreas T1 - Virtual Technology Labs - an efficient tool for the preparation of hands-on-MEMS-courses in training foundries N2 - Hands-on-training in high technology areas is usually limited due to the high cost for lab infrastructure and equipment. One specific example is the field of MEMS, where investment and upkeep of clean rooms with microtechnology equipment is either financed by production or R&D projects greatly reducing the availability for education purposes. For efficient hands-on-courses a MEMS training foundry, currently used jointly by six higher education institutions, was established at FH Kaiserslautern. In a typical one week course, students manufacture a micromachined pressure sensor including all lithography, thin film and packaging steps. This compact and yet complete program is only possible because participants learn to use the different complex machines in advance via a Virtual Training Lab (VTL). In this paper we present the concept of the MEMS training foundry and the VTL preparation together with results from a scientific evaluation of the VTL over the last three years. KW - Virtuelles Laboratorium KW - Virtuelles Labor KW - Hand-on-training KW - Virtual Technology Lab KW - MEMS ; education and training foundry Y1 - 2006 ER - TY - BOOK A1 - Mautner, Karin T1 - Numerical treatment of the Black-Scholes variational inequality in computational finance Y1 - 2006 N1 - Humboldt-Univ., Diss CY - Berlin ER - TY - JOUR A1 - Mang, Thomas A1 - Roosen, C. A1 - Ansorge, M. A1 - Leitner, W. T1 - Gaining pH-control in water/carbon dioxide biphasic systems / Abstract No. 1038 / Roosen, Ch. ; Ansorge, M. ; Mang, Thomas ; Leitner, W. ; Greiner, L. JF - Green solvents for processes : Lake Constance, Friedrichshafen, Germany, 8 - 11 October 2006 ; book of abstracts / DECHEMA e.V. Y1 - 2006 N1 - DECHEMA, Gesellschaft für Chemische Technik und Biotechnologie ; [Conference] ; ((Friedrichshafen) : 2006.10.08-11) PB - DECHEMA CY - Frankfurt am Main ER - TY - JOUR A1 - Mang, Thomas A1 - Kolz, J. A1 - Martins, J. A1 - Kremer, K. T1 - Investigation of Elastomer Foams by Single-Sided NMR / Kolz, J. ; Martins, J. ; Kremer, K. ; Blümich, B. ; Mang, Thomas JF - Kurzfassungen : 3. bis 6. Juli 2006, Nürnberg = Summaries / Deutsche Kautschuk Tagung, 3.7.-6.7.2006 Y1 - 2006 N1 - Deutsche Kautschuk-Tagung ; <2006, Nürnberg > SP - 33 PB - DKG, Dt. Kautschuk-Ges. CY - Frankfurt, Main ER - TY - CHAP A1 - Loeb, Horst W. A1 - Schartner, Karl-Heinz A1 - Seboldt, Wolfgang A1 - Dachwald, Bernd A1 - Streppel, Joern A1 - Meusemann, Hans A1 - Schülke, Peter T1 - SEP for a lander mission to the jovian moon europa T2 - 57th International Astronautical Congress N2 - Under DLR-contract, Giessen University and DLR Cologne are studying solar-electric propulsion missions (SEP) to the outer regions of the solar system. The most challenging reference mission concerns the transport of a 1.35-tons chemical lander spacecraft into an 80-RJ circular orbit around Jupiter, which would enable to place a 375 kg lander with 50 kg of scientific instruments on the surface of the icy moon "Europa". Thorough analyses show that the best solution in terms of SEP launch mass times thrusting time would be a two-stage EP module and a triple-junction solar array with concentrators which would be deployed step by step. Mission performance optimizations suggest to propel the spacecraft in the first EP stage by 6 gridded ion thrusters, running at 4.0 kV of beam voltage, which would save launch mass, and in the second stage by 4 thrusters with 1.25 to 1.5 kV of positive high voltage saving thrusting time. In this way, the launch mass of the spacecraft would be kept within 5.3 tons. Without a launcher's C3 and interplanetary gravity assists, Jupiter might be reached within about 4 yrs. The spiraling-down into the parking orbit would need another 1.8 yrs. This "large mission" can be scaled down to a smaller one, e.g., by halving all masses, the solar array power, and the number of thrusters. Due to their reliability, long lifetime and easy control, RIT-22 engines have been chosen for mission analysis. Based on precise tests, the thruster performance has been modeled. Y1 - 2006 U6 - http://dx.doi.org/10.2514/6.IAC-06-C4.4.04 N1 - 57th International Astronautical Congress, 02 October 2006 - 06 October 2006, Valencia, Spain. SP - 1 EP - 12 ER - TY - JOUR A1 - Leipold, M. A1 - Fichtner, H. A1 - Heber, B. A1 - Groepper, P. A1 - Lascar, S. A1 - Burger, F. A1 - Eiden, M. A1 - Niederstadt, T. A1 - Sickinger, C. A1 - Herbeck, L. A1 - Dachwald, Bernd A1 - Seboldt, W. T1 - Heliopause Explorer - A Sailcraft Mission to the Outer Boundaries of the Solar System JF - Acta Astronautica. 59 (2006), H. 8-11 Y1 - 2006 SN - 0094-5765 N1 - International Conference on Low Cost Planetary Missions <5, 2003, Noordwijk> ; Selected Proceedings SP - 786 EP - 796 ER - TY - CHAP A1 - Lei, Yu A1 - Mulchandani, Priti A1 - Chen, Wilfred A1 - Mulchandani, Ashok T1 - Biosensor for direct determination of fenitrothion and EPN using recombinant Pseudomonas putida JS444 with surface expressed organophosphorus hydrolase. 1. modified clark oxygen electrode N2 - This paper reports a first microbial biosensor for rapid and cost-effective determination of organophosphorus pesticides fenitrothion and EPN. The biosensor consisted of recombinant PNP-degrading/oxidizing bacteria Pseudomonas putida JS444 anchoring and displaying organophosphorus hydrolase (OPH) on its cell surface as biological sensing element and a dissolved oxygen electrode as the transducer. Surfaceexpressed OPH catalyzed the hydrolysis of fenitrothion and EPN to release 3-methyl-4-nitrophenol and p-nitrophenol, respectively, which were oxidized by the enzymatic machinery of Pseudomonas putida JS444 to carbon dioxide while consuming oxygen, which was measured and correlated to the concentration of organophosphates. Under the optimum operating conditions, the biosensor was able to measure as low as 277 ppb of fenitrothion and 1.6 ppm of EPN without interference from phenolic compounds and other commonly used pesticides such as carbamate pesticides, triazine herbicides and organophosphate pesticides without nitrophenyl substituent. The applicability of the biosensor to lake water was also demonstrated. KW - Biosensor KW - Organophosphorus KW - fenitrothion KW - EPN KW - biosensor KW - Pseudomonas putida Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1573 ER - TY - JOUR A1 - Kämper, Klaus-Peter A1 - Picard, A. A1 - Schütze, A. A1 - Wallach, D. T1 - Adopting the Foundry Concept of Semiconductor Fabrication on Educational Schemes and the Virtual Technology Lab (VTL). Picard, A.; Kämper, K.-P.; Schütze, A.; Wallach, D.; Walter, T. JF - Mst-News (2006) Y1 - 2006 SN - 0948-3128 SP - 15, 16 EP - u. 35 ER - TY - CHAP A1 - Kurz, Melanie T1 - Recognition of shape in virtual visualizations T2 - Proceedings : November 15 - 17, 2006, Technische Universität Darmstadt, Darmstadt, Germany ; PACE, Partners for the advancement of collaborative engineering education Y1 - 2006 SN - 978-3-00-020161-5 N1 - International PACE Forum Collaborative Visualization ; (2006, Darmstadt) SP - 203 EP - 209 PB - Techn. Univ. CY - Darmstadt ER - TY - CHAP A1 - Kreutz, Christian A1 - Lörgen, Jürgen A1 - Graewe, Boris A1 - Bargon, Joachim A1 - Yoshida, Mayumi A1 - Freso, Zachary M. A1 - Frèchet, Jean M. J. T1 - High frequency quartz micro balances: a promising path to enhanced sensitivity of gravimetric sensors N2 - An array of 50 MHz quartz microbalances (QMBs) coated with a dendronized polymer was used to detect small amounts of volatile organic compounds (VOCs) in the gas phase. The results were compared to those obtained with the commonly used 10 MHz QMBs. The 50 MHz QMBs proved to be a powerful tool for the detection of VOCs in the gas phase; therefore, they represent a promising alternative to the much more delicate surface acoustic wave devices (SAWs). KW - Biosensor KW - Quartz micro balances KW - electronic noses dendronized polymers inverted mesa technology Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1445 ER - TY - JOUR A1 - Krebsbach, M. A1 - Schiller, C. A1 - Brunner, D. A1 - Günther, G. A1 - Hegglin, M. I. A1 - Mottaghy, Darius A1 - Riese, M. A1 - Spelten, N. A1 - Wernli, H. T1 - Seasonal cycles and variability of O_3 and H_2O in the UT/LMS during SPURT JF - Atmospheric Chemistry and Physics Y1 - 2006 U6 - http://dx.doi.org/10.5194/acp-6-109-2006 VL - 6 IS - 1 SP - 109 EP - 125 ER - TY - CHAP A1 - Kraft, Bodo A1 - Retkowitz, Daniel T1 - Rule-Dependencies for Visual Knowledge Specification in Conceptual Design N2 - In: Proc. of the 11th Intl. Conf. on Computing in Civil and Building Engineering (ICCCBE-XI) ed. Hugues Rivard, Montreal, Canada, Seite 1-12, ACSE (CD-ROM), 2006 Currently, the conceptual design phase is not adequately supported by any CAD tool. Neither the support while elaborating conceptual sketches, nor the automatic proof of correctness with respect to effective restrictions is currently provided by any commercial tool. To enable domain experts to store the common as well as their personal domain knowledge, we develop a visual language for knowledge formalization. In this paper, a major extension to the already existing concepts is introduced. The possibility to define rule dependencies extends the expressiveness of the knowledge definition language and contributes to the usability of our approach. KW - CAD KW - CAD KW - Bauingenieurwesen KW - CAD KW - civil engineering Y1 - 2006 ER - TY - CHAP A1 - Kowalski, Julia A1 - McArdell, B. W. A1 - Bartelt, Perry T1 - A comparison of two approaches to modeling multiphase gravity currents T2 - Geophysical Research Abstracts Y1 - 2006 N1 - A-08738 VL - 8 ER - TY - CHAP A1 - Kowalski, Julia T1 - Numerical Debris Flow Simulation T2 - Schweizer Numerik Kolloquium : Book of Abstracts 12. April 2006 Y1 - 2006 ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Koshitz, I. N. A1 - Svetlowa, O. V. A1 - Zaseeva, M. V. T1 - Physiological principles of hypotensive therapy of open-angle glaucoma during presbyopic period. Part II Promising algorithms of practical sparing applications / Koshitz, I. N. ; Svetlova, O. V. ; Zaseeva, M. V. ; Shuhaev, S. V. ; Makarov, F. N. ; Kotliar JF - Glaukoma (2006) Y1 - 2006 N1 - Original in Russisch SP - 51 EP - 70 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Koshitz, I. N. A1 - Svetlova, O. V. A1 - Zaseeva, M. V. T1 - Physiological principles of hypotensive therapy of open-angle glaucoma during presbyopic period. Part I Initial theoretical presuppositions, hypotheses and facts / Koshitz, I. N. ; Svetlova, O. V. ; Zaseeva, M. V. ; Shuhaev, S. V. ; Makarov, F. N. ; Kotli JF - Glaukoma (2006) Y1 - 2006 N1 - Original in Russisch SP - 35 EP - 53 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Bauer, S. M. A1 - Zamuraev, L. A. T1 - Model of the transversely isotropic spherical layer for estimation of intraocular pressure changes after intravitreal injections / Bauer, S. M. ; Zamuraev, L. A. ; Kotliar, K. E. JF - Rossiiskii zhurnal biomekhaniki = Russian Journal of biomechanics. 10 (2006), H. 2 Y1 - 2006 SN - 1812-5123 SP - 41 EP - 47 PB - - ER - TY - CHAP A1 - Korsch, Helge A1 - Dafnis, Athanasios A1 - Reimerdes, Hans-Günther A1 - Braun, Carsten A1 - Ballmann, Josef T1 - Dynamic qualification of the HIRENASD elastic wing model T2 - Motto: Luft- und Raumfahrt: Lehre, Forschung, Industrie - gemeinsam innovativ. Deutscher Luft- und Raumfahrtkongress 2006 : Braunschweig, 06. bis 09. November 2006. Jahrbuch / Deutsche Gesellschaft für Luft- und Raumfahrt. 2006 Y1 - 2006 SP - 1441 EP - 1450 PB - Dt. Gesellschaft für Luft- und Raumfahrt - Lilienthal-Oberth (DGLR) CY - Bonn ER - TY - CHAP A1 - Koplin, Tobias J. A1 - Siemons, Maike A1 - Océn-Valéntin, César A1 - Sanders, Daniel A1 - Simon, Ulrich T1 - Workflow for high throughput screening of gas sensing materials N2 - The workflow of a high throughput screening setup for the rapid identification of new and improved sensor materials is presented. The polyol method was applied to prepare nanoparticular metal oxides as base materials, which were functionalised by surface doping. Using multi-electrode substrates and high throughput impedance spectroscopy (HT-IS) a wide range of materials could be screened in a short time. Applying HT-IS in search of new selective gas sensing materials a NO2-tolerant NO sensing material with reduced sensitivities towards other test gases was identified based on iridium doped zinc oxide. Analogous behaviour was observed for iridium doped indium oxide. KW - Biosensor KW - High throughput experimentation KW - gas sensor KW - metal oxide KW - doping KW - impedance spectroscopy KW - nitrogen oxides Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1407 ER - TY - JOUR A1 - Kolymbas, Dimitrios A1 - Fellin, W. A1 - Kirsch, Ansgar T1 - Squeezing due to stress relaxation in foliated rock JF - International journal for numerical and analytical methods in geomechanics Y1 - 2006 U6 - http://dx.doi.org/10.1002/nag.530 SN - 1096-9853 (E-Journal); 0363-9061 (Print) VL - Vol. 30 IS - Iss. 13 SP - 1357 EP - 1367 ER - TY - CHAP A1 - Kob, Malte A1 - Gömmel, Andreas A1 - Butenweg, Christoph A1 - Niendorf, Thoralf T1 - Training of a combined model of larynx and vocal folds with data from MRI measurements T2 - The 5th International Conference on Voice Physiology and Biomechanics: Variations across Cultures and Species, July 12-14, 2006, Tokyo, Japan. Proceedings Y1 - 2006 SP - 45 EP - 46 ER - TY - CHAP A1 - Kloock, Joachim P. A1 - Schubert, J. A1 - Ermelenko, Y. A1 - Vlasov, Y. G. A1 - Bratov, A. A1 - Schöning, Michael Josef T1 - Thin-film sensors with chalcogenide glass materials – a general survey T2 - Biochemical sensing utilisation of micro- and nanotechnologies : Warsaw, [23rd - 26th] November 2005 / ed. by M. Mascini ... Y1 - 2006 SP - 92 EP - 97 CY - Warsaw ER - TY - JOUR A1 - Kloock, Joachim P. A1 - Moreno, Lia A1 - Bratov, A. A1 - Huachupoma, S. A1 - Xu, J. A1 - Wagner, Torsten A1 - Yoshinobu, T. A1 - Ermolenko, Y. A1 - Vlasov, Y. G. A1 - Schöning, Michael Josef T1 - PLD-prepared cadmium sensors based on chalcogenide glasses —ISFET, LAPS and μISE semiconductor structures JF - Sensors and Actuators B: Chemical. 118 (2006), H. 1-2 Y1 - 2006 SN - 0925-4005 N1 - Eurosensors XIX - Eurosensors XIX - The 19th European Conference on Solid-State Transducers SP - 149 EP - 155 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Weber, S. A1 - Streun, M. A1 - Parl, C. A1 - Ziemons, Karl T1 - High resolution imaging with ClearPET™ Neuro - first animal images JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance. Y1 - 2006 SN - 1082-3654 SP - 1641 EP - 1644 ER - TY - CHAP A1 - Katz, Eugenii A1 - Willner, Itamar T1 - Magneto-controlled quantized electron transfer to surface-confined redox units and metal nanoparticles N2 - Hydrophobic magnetic nanoparticles (NPs) consisting of undecanoate-capped magnetite (Fe3O4, average diameter ca. 5 nm) are used to control quantized electron transfer to surface-confined redox units and metal NPs. A two-phase system consisting of an aqueous electrolyte solution and a toluene phase that includes the suspended undecanoatecapped magnetic NPs is used to control the interfacial properties of the electrode surface. The attracted magnetic NPs form a hydrophobic layer on the electrode surface resulting in the change of the mechanisms of the surface-confined electrochemical processes. A quinone-monolayer modified Au electrode demonstrates an aqueous-type of the electrochemical process (2e-+2H+ redox mechanism) for the quinone units in the absence of the hydrophobic magnetic NPs, while the attraction of the magnetic NPs to the surface results in the stepwise single-electron transfer mechanism characteristic of a dry nonaqueous medium. Also, the attraction of the hydrophobic magnetic NPs to the Au electrode surface modified with Au NPs (ca. 1.4 nm) yields a microenvironment with a low dielectric constant that results in the single-electron quantum charging of the Au NPs. KW - Biosensor KW - Nanoparticles KW - magnetic particles KW - quantum charging KW - modified electrode Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1528 ER - TY - BOOK A1 - Kaminsky, Radoslav A1 - Kallweit, Stephan A1 - Weber, Hans-Joachim A1 - Simons, Antoine A1 - Verdonck, Pascal T1 - Stereo high speed PIV measurements behind two different artificial heart valves Y1 - 2006 N1 - International Symposium on Applications of Laser Techniques to Fluid Mechanics <13, 2006, Lisboa> ER - TY - JOUR A1 - Kaminsky, Radoslav A1 - Kallweit, Stephan A1 - Weber, Hans-Joachim A1 - Simons, Antoine A1 - Kramm, K. A1 - Jazwik, K. A1 - Moll, J. A1 - Verdonck, P. T1 - 3D high speed piv assessment of a new aortic heart valve prototype JF - Journal of biomechanics. 39 (2006), H. Supplement 1 Y1 - 2006 SN - 0021-9290 N1 - World Congress of Biomechanics <5, 2006, München>: Abstracts of the 5th World Congress of Biomechanics SP - S304 EP - S305 PB - - ER - TY - BOOK A1 - Janz, Norbert A1 - Goedhuys, Micheline A1 - Mohnen, Pierre T1 - What drives productivity in Tanzanian manufacturing firms: technology or institutions? / Goedhuys, Micheline ; Janz, Norbert ; Mohnen, Pierre Y1 - 2006 N1 - Working paper series // United Nations University, UNU-MERIT ; 2006,037 PB - UnU-MERIT CY - Maastricht ER - TY - JOUR A1 - Hüning, Felix A1 - Eifert, T. A1 - Handrick, K. A1 - Neuhausen, U. T1 - Computational Magnetochemistry: Complementary Quantum Mechanical Tools / Eifert, T. ; Handrick, K. ; Hüning, F. ; Neuhausen, U. ; Schilder, H. ; Lueken, H. JF - Zeitschrift für Anorganische und Allgemeine Chemie (ZAAC) - Journal of Inorganic and General Chemistry . 632 (2006), H. 4 Y1 - 2006 SN - 1521-3749 SP - 521 EP - 529 PB - - ER - TY - JOUR A1 - Hüning, Felix A1 - Eifert, T. A1 - Handrick, K. A1 - Neuhausen, U. T1 - Computational Magnetochemistry: Complementary Quantum Mechanical Tools / Eifert, T. ; Handrick, K. ; Hüning, F. ; Neuhausen, U. ; Schilder, H. ; Lueken, H. JF - 20 Jahre Wilhelm-Klemm-Stiftung / Kuratorium der Wilhelm-Klemm-Stiftung (Hrsg.) Y1 - 2006 SN - 978-3-8322-5520-6 SP - 193ff PB - Shaker CY - Aachen ER - TY - CHAP A1 - Huth, Thomas A1 - Elsen, Olaf A1 - Hartwig, Christoph A1 - Esch, Thomas T1 - Innovative modular valve trains for 2015 - logistic benefits by EMVT T2 - IFAC Proceedings Volumes, Volume 39, Issue 3 N2 - In this paper the way to a 5-day-car with respect to a modular valve train systems for spark ignited combustion engines is shown. The necessary product diversity is shift from mechanical or physical components to software components. Therefore, significant improvements of logistic indicators are expected and shown. The working principle of a camless cylinder head with respect to an electromagnetical valve train (EMVT) is explained and it is demonstrated that shifting physical diversity to software is feasible. The future design of combustion engine systems including customisation can be supported by a set of assistance tools which is shown exemplary. Y1 - 2006 U6 - http://dx.doi.org/10.3182/20060517-3-FR-2903.00172 N1 - Part of special issue "12th IFAC Symposium on Information Control Problems in Manufacturing" SP - 315 EP - 320 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hoyler, Friedrich A1 - Aprahamian, A. A1 - Wu, X. A1 - Lesher, S. R. T1 - Complete spectroscopy of the 162Dy nucleus / Aprahamian, A. ; Wu, X. ; Lesher, S. R. ; Warner, D. D. ; Gelletly, W. ; Börner, H. G. ; Hoyler, F. ; Schreckenbach, K. ; Carsten R. F. ; Shi, Z. R. ; Kusnezov, D. ; Ibrahim, M. ; Macchiavelli, A. O. ; Brinkman JF - Nuclear physics / A. 764 (2006) Y1 - 2006 SN - 0375-9474 SP - 42 EP - 78 ER - TY - CHAP A1 - Hoffschmidt, Bernhard A1 - Schwarzer, Klemens A1 - Späte, Frank A1 - Kötter, Jens A1 - Ebert, Miriam A1 - Sierck, Olaf T1 - Development of a small modular parabolic trough collector T2 - 13th International Symposium Concentrated Solar Power and Chemical Energy Technologies : SolarPaces : June 20 - 23, 2006, Seville, Spain Y1 - 2006 SN - 8478345191 PB - SolarPaces CY - [o.O.] ER - TY - JOUR A1 - Hoffschmidt, Bernhard A1 - Becker, M. A1 - Fend, Thomas T1 - Theoretical and numerical investigation of flow stability in porous materials applied as volumetric solar receivers / M. Becker ; T. Fend ; B. Hoffschmidt ... JF - Solar energy. 80 (2006), H. 10 Y1 - 2006 SN - 0038-092X N1 - Solar Power and Chemical Energy Systems (SolarPACES’04) SP - 1241 EP - 1248 ER - TY - JOUR A1 - Hillgärtner, Michael A1 - Peier, Dirk T1 - Design of a Measurement Setup for the Impedance of Low-Resistance Plate-Conductors in the RF-Range JF - Proceedings of the 10th International Conference on Optimization of Electrical and Electronic Equipment, OPTIM '06, Braşov, May 18 - 20, 2006 / ed. by The Transilvania University of Braşov, Faculty of Electrical Engineering and Computer Science. [Ed. Mihai Cernat .̤] . - Vol. 1: Keynote addresses, electrotechnics Y1 - 2006 SN - 978-973-635703-9 N1 - International Conference on Optimization of Electrical and Electronic Equipment <10, 2006, Braşov>; OPTIM <10, 2006, Braşov> SP - 59 EP - 64 CY - Braşov ER - TY - JOUR A1 - Hillgärtner, Michael A1 - Kappel, U. T1 - Radiating Impedance of Mains Cabling During Emissions Testing JF - EMC Europe 2006 Barcelona : International Symposium on Electromagnetic Compatibility; September 4 - 8, 2006, Campus Nord, Technical University of Catalonia, Barcelona, Spain / [organized by Technical University of Catalonia (UPC) ... Ed. and publ. by: Ferran Silva ...]. - Vol. 1: Proceedings 1 Y1 - 2006 SN - 84-689-9439-1 N1 - EMC Europe <7,2006,Barcelona>; International Symposium on Electromagnetic Compatibility <7, 2006, Barcelona> SP - 17 EP - 22 CY - Barcelona ER - TY - JOUR A1 - Heuermann, Holger A1 - Erkens, H. T1 - Novel RF switch concepts for differential wireless communications frontends. Erkens, H.; Heuermann, H. JF - IEEE Transactions on Microwave Theory and Techniques. 54 (2006), H. 6, Part 1 Y1 - 2006 SN - 0018-9480 SP - 2376 EP - 2382 ER - TY - JOUR A1 - Heuermann, Holger T1 - Verringerung des Phasenrauschens von Oszillatoren durch Dual-Mode-Resonatoren JF - HF-Report. 20 (2006), H. 5-6 Y1 - 2006 SN - 1431-827X SP - 43 EP - 48 ER - TY - JOUR A1 - Heuermann, Holger T1 - Multiport S-parameter calculation from two-port network analyzer measurements with or without switch matrix JF - ARFTG Conference, 2006 67th, San Francisco, CA Y1 - 2006 SN - 978-0-7803-9529-9 SP - 219 EP - 222 ER - TY - CHAP A1 - Herrmann, Ulf A1 - Worringer, S. A1 - Graeter, F. A1 - Nava, P. ED - Romero, Manuel T1 - Three Years of Operation Experience of the SKAL-ET Collector Loop at SEGS V T2 - 13th International Symposium Concentrated Solar Power and Chemical Energy Technologies, June 20 - 23, 2006, Seville, Spain Y1 - 2006 SN - 84-7834-519-1 PB - SolarPACES [u.a.] CY - [s.l.] ER - TY - JOUR A1 - Hellwig, Angelika A1 - Volkmann, Lutz T1 - Lower bounds on the vertex-connectivity of digraphs and graphs JF - Information processing letters Y1 - 2006 SN - 1872-6119 (E-Journal); 0020-0190 (Print) VL - Vol. 99 IS - Iss. 2 SP - 41 EP - 46 ER - TY - JOUR A1 - Hellwig, Angelika A1 - Volkmann, Lutz T1 - On connectivity in graphs with given clique number JF - Journal of graph theory Y1 - 2006 SN - 03649024 ; 10970118 VL - Vol. 52 IS - Iss. 1 SP - 7 EP - 14 ER - TY - JOUR A1 - Hellwig, Angelika A1 - Volkmann, Lutz T1 - Some upper bounds for the domination number JF - The journal of combinatorial mathematics and combinatorial computing : JCMCC Y1 - 2006 SN - 0835-3026 VL - Vol. 57 SP - 187 EP - 209 ER - TY - CHAP A1 - Hellmanns, Mark A1 - Böhm, Stefan A1 - Dilger, Klaus T1 - Implementation of a velocity controlled manual applicator for adhesives and sealants in the automotive industry in consideration of quality control T2 - Proceedings of the 29th annual meeting of the Adhesion Society : 19. - 22.2.2006, Jacksonville, Florida Y1 - 2006 SN - 1086-9506 SP - 68 EP - 70 PB - Adhesion Society CY - Blacksburg, Va. ER -