TY - JOUR A1 - Glowania, Michael A1 - Gries, Thomas A1 - Schoene, Jens A1 - Schleser, Markus A1 - Reisgen, Uwe T1 - Innovative coating technology for textile reinforcements of concrete applications JF - 13th International Congress on Polymers in Concrete : 10 - 12 February 2010, Funchal, Madeira, Portugal.(Key engineering materials. Vol. 466) Y1 - 2011 SN - 978-3-03785-008-4 SN - 1013-9826 (E-Journal) ; 0252-1059 (Print) SP - 167 EP - 173 PB - Trans Tech Publications CY - Bäch ER - TY - JOUR A1 - Mukherjee, Krishnendu A1 - Ramazani, Ali A1 - Yang, Li A1 - Prahl, Ulrich A1 - Bleck, Wolfgang A1 - Reisgen, Uwe A1 - Schleser, Markus A1 - Abdurakhmanov, Aydemir T1 - Characterization of gas metal arc welded hot rolled DP600 steel JF - Steel research international Y1 - 2011 SN - 1869-344X (E-Book); 1611-3683 (Print) VL - Vol. 82 IS - Iss. 12 SP - 1408 EP - 1416 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Mukherjee, Krishnendu A1 - Prahl, Ulrich A1 - Bleck, Wolfgang A1 - Reisgen, Uwe A1 - Schleser, Markus A1 - Abdurakhmanov, Aydemir T1 - Characterization and modelling techniques for gas metal arc welding of DP 600 sheet steels JF - Materialwissenschaft und Werkstofftechnik N2 - The objectives of the present work are to characterize the Gas Metal Arc Welding process of DP 600 sheet steel and to summarize the modelling techniques. The time-temperature evolution during the welding cycle was measured experimentally and modelled with the softwaretool SimWeld. To model the phase transformations during the welding cycle dilatometer tests were done to quantify the parameters for phase field modelling by MICRESS®. The important input parameters are interface mobility, nucleation density, etc. A contribution was made to include austenite to bainite transformation in MICRESS®. This is useful to predict the microstructure in the fast cooling segments. The phase transformation model is capable to predict the microstructure along the heating and cooling cycles of welding. Tensile tests have shown the evidence of failure at the heat affected zone, which has the ferrite-tempered martensite microstructure. Y1 - 2010 U6 - https://doi.org/10.1002/mawe.201000692 SN - 1521-4052 VL - 41 IS - 11 SP - 972 EP - 983 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Reisgen, Uwe A1 - Schleser, Markus A1 - Mokrov, Oleg A1 - Ahmed, Essam T1 - Uni- and bi-axial deformation behavior of laser welded advanced high strength steel sheets JF - Journal of materials processing technology N2 - Bead-on-plate butt joints of 2.5 mm hot rolled DP600/DP600 and 1.2 mm cold rolled TRIP700/TRIP700 steel sheets were performed using 6 kW CO2 laser beam welding. The welding speed ranged from 1.5 to 3.0 and from 2.1 to 3.9 m/min in DP/DP and TRIP/TRIP steel weldments respectively. A top surface helium gas was used as a shielding gas at a flow rate of 20 l/min. Metallographic examinations and transverse tensile testing (DIN EN 895: 1995) were carried out to characterize the weldments. The formability of base metals and weldments were investigated by standard Erichsen test (DIN EN ISO 20482). It was found that the uniaxial plastic behavior of both DP600 and TRIP700 base metals was in agreement with Swift and modified Mecking–Kocks models respectively. In a perpendicular tensile test to the weld line, all specimens were fractured at the base metal however the strengths were somewhat higher than those of base metal. There was a significant reduction in formability caused by welding of both DP/DP and TRIP/TRIP steel weldments and the formability has been improved with the increase of the welding speed. Y1 - 2010 U6 - https://doi.org/http10.1016/j.jmatprotec.2010.08.003 SN - 0924-0136 VL - 210 IS - 15 SP - 2188 EP - 2196 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Reisgen, Uwe A1 - Schleser, Markus A1 - Mokrov, Oleg A1 - Ahmed, Essam T1 - Shielding gas influences on laser weldability of tailored blanks of advanced automotive steels JF - Applied surface science N2 - The effects of shielding gas types and flow rates on CO2 laser weldability of DP600/TRIP700 steel sheets were studied in this work. The evaluated shielding gases were helium (He), argon (Ar) and different mixtures of He and Ar. Weld penetration, tensile strength and formability (Erichsen test) of laser welds were found to be strongly dependent upon the shielding gas types. The ability of shielding gas in removing plasma plume and thus increasing weld penetration is believed to be closely related to ionization potential and atomic weight which determine the period of plasma formation and disappearance. It was found that the higher helium shielding gas flow rate, the deeper weld penetration and the lower weld width. Y1 - 2010 U6 - https://doi.org/10.1016/j.apsusc.2010.08.042 SN - 0169-4332 (E-Journal); 0169-4332 (Print) VL - 257 IS - 5 SP - 1401 EP - 1406 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ahmed, Essam A1 - Reisgen, Uwe A1 - Schleser, Markus A1 - Mokrov, Oleg T1 - On formability of tailor laser welded blanks of DP/TRIP steel sheets JF - Science and technology of welding and joining N2 - This paper aims to evaluate the formability of tailor welded blanks of dual phase (DP600)/transformation induced plasticity (TRIP700) steel sheets. In this work, bead on plate butt joints of 2·5 mm DP600 and 1·2 mm TRIP700 steel sheets were performed using CO2 laser beam welding. Microhardness measurements and transverse tensile testing were carried out to characterise the welds. The formability of base metals and welds were investigated by standard Erichsen test. In a perpendicular tensile test to the weld line, all specimens were fractured at the TRIP base metal, and the strengths were somewhat higher than those of base metal. There was a significant reduction in formability caused by welding of the DP600/TRIP700 steel sheets, and the formability increased with increasing welding speed. Y1 - 2010 U6 - https://doi.org/10.1179/136217110X12731414739754 SN - 1743-2936 VL - 15 IS - 5 SP - 337 EP - 342 PB - Maney CY - Leeds ER - TY - JOUR A1 - Dilthey, Ulrich A1 - Schleser, Markus A1 - Feldmann, Martin A1 - Pak, Daniel A1 - Geßler, Achim T1 - Investigation of punctiform, plane and hybrid joints of textile-reinforced concrete parts JF - Cement and concrete composites Y1 - 2008 SN - 0958-9465 VL - Vol. 30 IS - iss. 2 SP - 82 EP - 87 ER - TY - JOUR A1 - Feldmann, Markus A1 - Pak, Daniel A1 - Geßler, Achim A1 - Dilthey, Ulrich A1 - Schleser, Markus T1 - Bonded connections for textile reinforced concrete structures JF - Cailiao-gongcheng = Journal of materials engineering Y1 - 2006 SN - 1001-4381 IS - Special iss. SP - 123 EP - 127 ER - TY - JOUR A1 - Schleser, Markus A1 - Walk-Lauffer, Bernd A1 - Raupach, Michael A1 - Dilthey, Ulrich T1 - Application of polymers for textile-reinforced concrete JF - Journal of materials in civil engineering : properties, applications, durability Y1 - 2006 SN - 0899-1561 VL - 18 IS - 5 SP - 670 EP - 676 ER - TY - JOUR A1 - Agrafiotis, Christos C. A1 - Mavroidis, Ilias A1 - Konstandopoulos, Athansios G. A1 - Hoffschmidt, Bernhard A1 - Stobbe, Per A1 - Romero, Manuel A1 - Fernandez-Quero, Valerio T1 - Evaluation of porous silicon carbide monolithic honeycombs as volumetric receivers/collectors of concentrated solar radiation JF - Solar energy materials and solar cells Y1 - 2007 SN - 1879-3398 (E-Journal); 0927-0248 (Print) VL - Vol. 91 IS - Iss. 6 SP - 474 EP - 488 ER - TY - JOUR A1 - Dilthey, Ulrich A1 - Brandenburg, Annette A1 - Schleser, Markus T1 - Dispensing and application of unfilled adhesives in the micro range JF - Welding and cutting. 3 (2004), H. 4 Y1 - 2004 SN - 1612-3433 SP - 250 EP - 254 ER - TY - JOUR A1 - Velraj, R. A1 - Seeniraj, R. V. A1 - Hafner, B. A1 - Faber, Christian A1 - Schwarzer, Klemens T1 - Heat transfer enhancement in a latent heat storage system JF - Solar energy. Vol. 65, iss. 3 Y1 - 1999 SN - 0038-092X SP - 171 EP - 180 ER - TY - JOUR A1 - Schwarzer, Klemens A1 - Vieira da Silva, Maria Eugenia A1 - Schwarzer, Tarik T1 - Field results in Namibia and Brazil of the new solar desalination system for decentralised drinking water production JF - Desalination and water treatment. Vol. 31 (2011), iss. 1-3: selected papers presented at EuroMed 2010 — Desalination for Clean Water and Energy: Cooperation among Mediterranean Countries of Europe and MENA Region, 3–7 October 2010, Tel Aviv, Israel Y1 - 2011 SP - 379 EP - 386 ER - TY - JOUR A1 - Schusser, Sebastian A1 - Menzel, S. A1 - Bäcker, Matthias A1 - Leinhos, Marcel A1 - Poghossian, Arshak A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - Degradation of thin poly(lactic acid) films: characterization by capacitance-voltage, atomic force microscopy, scanning electron microscopy and contact-angle measurements JF - Electrochimica Acta Y1 - 2013 SN - 1873-3859 (E-Journal); 0013-4686 (Print) VL - Vol. 113 SP - 779 EP - 784 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Porschen, W. A1 - Gartzen, J. A1 - Gewehr, K. A1 - Mühlensiepen, H. A1 - Weber, Hans-Joachim A1 - Feinedegen, L E. T1 - In vivo assay of the radiation sensitivity of hypoxic tumour cells : influence of γ-rays, cyclotron neutrons, misonidazole, hyperthermia and mixed modalities JF - The British journal of cancer / Supplement N2 - Tumour cell death can be evaluated in the living mouse by externally measuring the rate of loss of tumour-bound DNA tracer. By sequentially labelling the tumour-bearing animals with ¹²⁵IUdR and ¹³¹IUdR 50 h apart, the average tumour cells at the time of the second injection are labelled by ¹²⁵IUdR and the euoxic tumour cells are specifically labelled with ¹³¹IUdR. Tumour treatment at this stage of labelling permits the observation of the reaction of euoxic cells and average tumour cells and finally yields data on hypoxic cells and thus on the oxygen enhancement ratio. This information adds to results from tumour control and growth delay. With this technique effects were analysed of 60-Co γ-rays, cyclotron neutrons (E = 6 MeV), misonidazole (500 mg/kg body wt) and hyperthermia (42°C water-bath), or combinations of these. Misonidazole (15 min before irradiation) altered the oxygen enhancement ratio by a factor of 1·5 for γ-rays and of 1·1 for neutrons; when evaluated from tumour-growth delay and TCD-50 misonidazole gave a dose modifying factor of 1·47 for γ-rays and of 1·2-1·3 for neutrons. Based on percentage tumour regression 100 days after treatment, the enhancement ratio from hyperthermia (after irradiation) was 2·75 for γ-rays (at 10 Gray) and 2·2 for neutrons (at 3·2 Gray). For neutrons combined with misonidazole and hyperthermia the ratio was 2·4. These results demonstrate that effects of neutron irradiation may be modified by electron-affinic substances and/or hyperthermia. Y1 - 1978 SN - 0306-9443 N1 - Section 6: Sensitization and Hypoxic Cytotoxicity: Effects of Hyperthermia and High Let IS - 3 SP - 194 EP - 197 PB - Lewis CY - London ER - TY - JOUR A1 - Wang, Mao A1 - Anik, Sabri A1 - Frohberg, Martin G. T1 - Thermodynamics of oxygen in the lead-antimony system at 1173 K JF - Erzmetall : Rohstoffgewinnung, Verarbeitung, Recycling, Umwelttechnik Y1 - 1987 SN - 0044-2658 VL - 40 IS - 6 SP - 316 EP - 319 ER - TY - JOUR A1 - Anik, Sabri A1 - Frohberg, Martin G. T1 - Thermodynamics of oxygen in the copper-antimony system at 1473K JF - Erzmetall : Rohstoffgewinnung, Verarbeitung, Recycling, Umwelttechnik Y1 - 1988 SN - 0044-2658 VL - 41 IS - 10 SP - 498 EP - 501 ER - TY - JOUR A1 - Wemhöner, Carsten A1 - Hafner, Bernd A1 - Schwarzer, Klemens T1 - Simulation of solar thermal systems with CARNOT blockset in the environment MATLAB-Simulink Y1 - 2000 SP - 1 EP - 6 ER - TY - JOUR A1 - Wang, Mao A1 - Anik, Sabri A1 - Frohberg, Martin G. T1 - Experiments on the electrochemical determination of the sulphur activities in the system copper-silver at 1200°C JF - Zeitschrift für Metallkunde Y1 - 1988 SN - 0044-3093 VL - 79 IS - 5 SP - 336 EP - 339 ER - TY - JOUR A1 - Anik, Sabri A1 - Frohberg, Martin G. T1 - Thermodynamics and solubility of oxygen in liquid bismuth-lead and bismuth-antimony alloys JF - Berichte der Bunsengesellschaft für physikalische Chemie Y1 - 1987 SN - 0940-483X SN - 0005-9021 VL - 91 IS - 7 SP - 790 EP - 794 ER - TY - JOUR A1 - Frohberg, Martin G. A1 - Anik, Sabri T1 - Thermodynamic relations between component activities and gas solubilities in binary metallic systems JF - Berichte der Bunsengesellschaft für physikalische Chemie Y1 - 1985 SN - 0940-483X SN - 0005-9021 VL - 89 IS - 2 SP - 130 EP - 134 ER - TY - JOUR A1 - Anik, Sabri A1 - Frohberg, Martin G. A1 - Kapoor, Madan Lal T1 - Experiments and theoretical considerations on the solution of oxygen in binary metal alloys JF - Berichte der Bunsengesellschaft für physikalische Chemie Y1 - 1983 SN - 0005-9021 SN - 0940-483X VL - 87 IS - 12 SP - 1201 EP - 1204 ER - TY - JOUR A1 - Anik, Sabri A1 - Frohberg, Martin G. T1 - Thermodynamics and solubility of oxygen in liquid copper-lead alloys at 1200°C from E.M.F. measurements JF - Berichte der Bunsengesellschaft für physikalische Chemie Y1 - 1984 SN - 0940-483X SN - 0005-9021 VL - 88 IS - 8 SP - 707 EP - 710 ER - TY - JOUR A1 - Laack, Walter van T1 - The genetic code should be seen as a positioning code JF - British journal of arts and social sciences. Vol. 14 (2013), No. 1 Y1 - 2013 SN - 2046-9578 SP - 93 EP - 97 ER - TY - JOUR A1 - Kramer, Friederike A1 - Halamkova, Lenka A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Katz, Evgeny A1 - Halamek, Jan T1 - Biocatalytic analysis of biomarkers for forensic identification of ethnicity between Caucasian and African American JF - The analyst. August 2013 Y1 - 2013 SN - 1364-5528 (E-Journal); 0003-2654 (Print) VL - Vol. 138 SP - 6251 EP - 6257 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Meliß, Michael A1 - Neskakis, A. A1 - Plettner-Marliani, J. A1 - Lange, C. A1 - Hövelmann, A. A1 - Schumacher, J. T1 - Waste water recycling supplied by renewable energies : basic conditions and possible treatment technologies JF - Renewable energy. Vol. 14 (1998), iss. 1-4. 6th Arab International Solar Energy Conference: Bringing Solar Energy into the Daylight, Muscat, Sultanate of Oman, 29.03.-01.04.1998 Y1 - 1998 SN - 1879-0682 (E-Book); 0960-1481 (Print) SP - 325 EP - 331 ER - TY - JOUR A1 - Anik, Sabri A1 - Frohberg, Martin G. A1 - Kapoor, Madan Lal T1 - Prediction of thermodynamic properties of oxygen in binary metallic solvents JF - Zeitschrift für Metallkunde Y1 - 1983 SN - 0044-3093 VL - 74 IS - 6 SP - 372 EP - 375 ER - TY - JOUR A1 - Anik, Sabri A1 - Kapoor, Madan Lal A1 - Frohberg, Martin G. T1 - Thermodynamic behaviour of oxygen in molten substitutional alloy solvents JF - Zeitschrift für Metallkunde Y1 - 1983 SN - 0044-3093 VL - 74 IS - 1 SP - 53 EP - 58 ER - TY - JOUR A1 - Anik, Sabri A1 - Frohberg, Martin G. T1 - Investigation of the thermodynamics of oxygen and the determination of phase boundaries in the system copper-oxygen-bismuth at 12000C JF - Zeitschrift für Metallkunde Y1 - 1983 SN - 0044-3093 VL - 74 IS - 8 SP - 530 EP - 534 ER - TY - JOUR A1 - Frohberg, Martin G. A1 - Anik, Sabri T1 - The application of a quadi-chemical lattice model to binary metallic solvents containing oxygen in higher concentrations JF - Zeitschrift für Metallkunde Y1 - 1983 SN - 0044-3093 VL - 74 IS - 10 SP - 665 EP - 666 ER - TY - JOUR A1 - Anik, Sabri A1 - Frohberg, Martin G. T1 - Investigations of the thermodynamics of oxygen and the determination of the miscibility gap in the system copper-oxygen-lead at 12000C JF - Zeitschrift für Metallkunde Y1 - 1984 SN - 0044-3093 VL - 75 IS - 8 SP - 586 EP - 589 ER - TY - JOUR A1 - Frohberg, Martin G. A1 - Anik, Sabri T1 - The calculation of component activities of binary metallic melts from their gas solubilities JF - Zeitschrift für Metallkunde Y1 - 1985 SN - 0044-3093 VL - 76 IS - 2 SP - 135 EP - 137 ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Trattner, Barbara A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Stütz, Evamaria A1 - Schmitt-Landsiedel, Doris A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - A critical comparison of cell-based sensor systems for the detection of Cr (VI) in aquatic environment JF - Sensors and actuators. B: Chemical Y1 - 2013 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - Vol. 182 SP - 58 EP - 65 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Ichimura, Hiroki A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel JF - Sensors and actuators. B: Chemical N2 - The chemical imaging sensor is a device to visualize the spatial distribution of chemical species based on the principle of LAPS (light-addressable potentiometric sensor), which is a field-effect chemical sensor based on semiconductor. In this study, the chemical imaging sensor has been applied to investigate the ion profile of laminar flows in a microfluidic channel. The chemical images (pH maps) were collected in a Y-shaped microfluidic channel while injecting HCl and NaCl solutions into two branches. From the chemical images, it was clearly observed that the injected solutions formed laminar flows in the channel. In addition, ion diffusion across the laminar flows was observed, and the diffusion coefficient could be derived by fitting the pH profiles to the Fick's equation. Y1 - 2013 U6 - https://doi.org/10.1016/j.snb.2013.04.057 SN - 1873-3077 (E-Journal); 0925-4005 (Print) N1 - Part of special issue "Selected Papers from the 26th European Conference on Solid-State Transducers" VL - 189 SP - 240 EP - 245 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jens, Otto A1 - Kaldenhoff, E. A1 - Kirschner-Hermanns, R. A1 - Mühl, Thomas A1 - Klinge, Uwe T1 - Elongation of textile pelvic floor implants under load is related to complete loss of effective porosity, thereby favoring incorporation in scar plates JF - Journal of biomedical materials research. Part A N2 - Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome. Y1 - 2014 U6 - https://doi.org/10.1002/jbm.a.34767 SN - 1552-4965 VL - 102 IS - 4 SP - 1079 EP - 1084 PB - Wiley CY - New York ER - TY - JOUR A1 - Meliß, Michael A1 - Oesterwind, Dieter A1 - Voß, Alfred T1 - Non-nuclear and non-fossil energy resources and their possibilities for future power generation JF - Kerntechnik N2 - It must be stressed that the assessment of the exploitation possibilities of the energy resources discussed in this paper requires further studies. With this proviso, the situation can be provisionally summarised as follows: The total potential of known geothermal steam sources is only 64 GW. Geothermal energy could therefore only make a significant contribution to covering the worldwide power needs if we succeed in exploiting dry geothermal reservoirs. Exploitation of tidal energy is limited to a few geographically favourable locations. The power generation potential at these locations is only about 64 GW. An important drawback of tidal power is discontinuous power generation. Large scale exploitation of wind, wave and glacier energy, and of ocean heat, requires solution of a number of technological problems. The environmental effects of exploitation of these energy resources are to some extent of a qualitatively different nature from those of operation of fossil-fuel-fired and of nuclear power plants. The scanty knowledge in this area often results in these effects being underestimated. In any case, however, it would be deliberately misleading to postulate that any form of power generation is possible without some detrimental effects on the environment. It may be stated in conclusion that, owing to their small potential or to the as yet insufficiently advanced technological development, none of the energy resources discussed in this paper can make a significant contribution to the solution of middle-term energy supply problems, i.e., to a rapid replacement of mineral oil and natural gas. Y1 - 1975 U6 - https://doi.org/10.18419/opus-8093 SN - 0932-3902 N1 - Printausg. in der Bibliothek vorhanden: 63 ZS 010-1975 VL - 17 IS - 7 SP - 301 EP - 306 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Ferrein, Alexander A1 - Meyer, Thomas T1 - A Brief Overview of Artificial Intelligence in South Africa JF - AI Magazine N2 - South Africa in recent years is the establishment of a number of research hubs involved in AI activities ranging from mobile robotics and computational intelligence, to knowledge representation and reasoning, and human language technologies. In this survey we take the reader through a quick tour of the research being conducted at these hubs, and touch on an initiative to maintain and extend the current level of interest in AI research in the country. Y1 - 2012 U6 - https://doi.org/10.1609/aimag.v33i1.2357 SN - 0738-4602 VL - 33 IS - 1 SP - 99 EP - 101 PB - AAAI CY - Menlo Park ER - TY - JOUR A1 - Abulnaga, El-Hussiny A1 - Pinkenburg, Olaf A1 - Schiffels, Johannes A1 - E-Refai, Ahmed A1 - Buckel, Wolfgang A1 - Selmer, Thorsten T1 - Effect of an Oxygen-Tolerant Bifurcating Butyryl Coenzyme A Dehydrogenase/Electron-Transferring Flavoprotein Complex from Clostridium difficile on Butyrate Production in Escherichia coli JF - Journal of bacteriology Y1 - 2013 SN - 1098-5530 [E-Journal] SN - 0021-9193 [Print] VL - 195 IS - 16 SP - 3704 EP - 3713 ER - TY - JOUR A1 - Abdel-Latif, Lotfie Ahmed A1 - Peeken, Heinz A1 - Benner, Joachim T1 - Thermohydrodynamic analysis of thrust-bearing with circular pads running on bubbly oil (BTHD-theory) JF - Journal of tribology Y1 - 1985 SN - 0742-4787 SN - 1528-8897 VL - 107 IS - 4 SP - 527 EP - 537 ER - TY - JOUR A1 - Meliß, Michael A1 - Späte, Frank T1 - The solar heating system with seasonal storage at the Solar-Campus Jülich JF - Solar energy. Vol. 69 (2000), iss. 6 Y1 - 2000 SN - 0038-092X SP - 525 EP - 533 ER - TY - JOUR A1 - Rens, Gavin A1 - Ferrein, Alexander T1 - Belief-node condensation for online POMDP algorithms N2 - Slightly extended version of the paper accepted at the Robotics and Artificial Intelligence Workshop, a special track of IEEE AFRICON-2013, held in Mauritius, 9-12 September 2013 Y1 - 2013 SP - 1 EP - 7 PB - IEEE CY - New York ER - TY - JOUR A1 - Kirstein, Simon A1 - Müller, Karsten A1 - Walecki-Mingers, Mark A1 - Deserno, Thomas M. T1 - Robust adaptive flow line detection in sewer pipes JF - Automation in construction N2 - As part of a novel approach to automatic sewer inspection, this paper presents a robust algorithm for automatic flow line detection. A large image repository is obtained from about 50,000 m sewers to represent the high variability of real world sewer systems. Automatic image processing combines Canny edge detection, Hough transform for straight lines and cost minimization using Dijkstra's shortest path algorithm. Assuming that flow lines are mostly smoothly connected horizontal structures, piecewise flow line delineation is reduced to a process of selecting adjacent line candidates. Costs are derived from the gap between adjacent candidates and their reliability. A single parameter α enables simple control of the algorithm. The detected flow line may precisely follow the segmented edges (α = 0.0) or minimize gaps at joints (α = 1.0). Both, manual and ground truth-based analysis indicate that α = 0.8 is optimal and independent of the sewer's material. The algorithm forms an essential step to further automation of sewer inspection. Y1 - 2012 U6 - https://doi.org/10.1016/j.autcon.2011.05.009 SN - 1872-7891 (E-Journal) ; 0926-5805 (Print) IS - 21 SP - 24 EP - 31 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schiffels, Johannes A1 - Pinkenburg, Olaf A1 - Schelden, Maximilian A1 - Aboulnaga, El-Hussiny A. A. A1 - Baumann, Marcus A1 - Selmer, Thorsten T1 - An innovative cloning platform enables large-scale production and maturation of an oxygen-tolerant [NiFe]-hydrogenase from cupriavidus necator in Escherichia coli JF - PLOS one. 2013 Y1 - 2013 U6 - https://doi.org/10.1371/journal.pone.0068812 SN - 1932-6203 PB - Public Library of Science CY - San Francisco, California ER - TY - JOUR A1 - Sommer, Ferdinand A1 - Gerling, Ulrich A1 - Predel, Bruno T1 - On the evaluation of interchange energies and the equilibrium-constant from mixing enthalpies of a regular associated solution-comment JF - Zeitschrift für Metallkunde : international journal of materials research and advanced techniques. Bd. 75, H. 11 Y1 - 1984 SN - 0044-3093 ; 0179-4841 SP - 898 ER - TY - JOUR A1 - Arpshofen, Ingo A1 - Pool, M. J. A1 - Sommer, Ferdinand A1 - Gerling, Ulrich A1 - Predel, Bruno A1 - Schultheiss, Emil T1 - Determination of the integral mixing enthalpies in the Cu-Pd-Si liquid ternary alloy system at 1600 K JF - Zeitschrift für Metallkunde : international journal of materials research and advanced techniques. Bd. 74, H. 1 Y1 - 1983 SN - 0044-3093 ; 0179-4841 SP - 25 EP - 32 ER - TY - JOUR A1 - Gerling, Ulrich A1 - Pool, M. J. A1 - Predel, Bruno T1 - A contribution to the associate model for binary liquid alloys = Ein Beitrag zum Assoziat-Modell für binäre flüssige Legierungen JF - Zeitschrift für Metallkunde : international journal of materials research and advanced techniques. Bd. 74, H. 9 Y1 - 1983 SN - 0044-3093 ; 0179-4841 SP - 616 EP - 619 ER - TY - JOUR A1 - Sommer, F. A1 - Gerling, Ulrich A1 - Predel, Bruno T1 - Comments on 'On the evaluation of interchange energies and the equilibrium constant from mixing enthalpies of a regular associated solution' by S. Lele, G.V.S. Sastry, and P. Ramachandrarao = Kommentar zu 'Zur Berechnung der Wechselwirkungsenergien und der Gleichgewichtskonstanten aus Mischungsenthalpien in regulären assoziierten Lösungen' von S. Lele, G.V.S. Sastry und P. Ramachandrarao JF - Zeitschrift für Metallkunde : international journal of materials research and advanced techniques. Bd. 75, H. 6 Y1 - 1984 SN - 0044-3093 ; 0179-4841 SP - 449 EP - 454 ER - TY - JOUR A1 - Lück, Reinhard A1 - Gerling, Ulrich A1 - Predel, Bruno T1 - An entropy paradox of the association model JF - Zeitschrift für Metallkunde : international journal of materials research and advanced techniques. Bd. 80, H. 4 Y1 - 1989 SN - 0044-3093 ; 0179-4841 SP - 270 EP - 275 ER - TY - JOUR A1 - Hardt, Arno A1 - Martin, S. A1 - Meißburger, J. A1 - Retz, R. A1 - Wimmer, J. T1 - The cryopump system of the QQDDQ magnet spectrometer BIG KARL JF - Vacuum N2 - Cryopumps without liquid nitrogen shielding are used to provide a vacuum of 10−6 torr in the spectrometer. The vacuum system is subdivided in three sections that can be separated by valves. The first section (scattering chamber) has a volume of 60 l, two rotation transmissions with 35 cm dia and a sliding seal that allows a rotation of 160° without deteriorating the vacuum. The second section includes the vacuum chambers inside the magnets with 6 × 80 cm cross-section and a length of 1200 cm. The third section (detector box) has a volume of 4300 l and contains a moveable detector system. The gas inside the detector with a pressure of 760 torr is separated from the vacuum by a 15 μm mylar foil with an area of 300 cm2. The detector box can be valved off by a valve with the dimension of 10 × 100 cm. The layout of system is given. The instrumentation and the interlock system are described. First experiences with this system are presented. Y1 - 1978 U6 - https://doi.org/10.1016/S0042-207X(78)80026-8 SN - 1879-2715 (E-Journal); 0042-207X (Print) VL - 28 IS - 10-11 SP - 483 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Berg, G. P. A. A1 - Demarteau, M. A1 - Hardt, Arno A1 - Hürlimann, W. A1 - Martin, S. A. A1 - Meissburger, J. A1 - Oelert, W. A1 - Seyfart, H. A1 - Styczen, B. A1 - Köhler, M. A1 - Oelrich, I. A1 - Scheerer, J. T1 - High resolution spectroscopy of 102Ru(d, p)103Ru and 104Ru(p, d)103Ru reactions JF - Nuclear Physics A. Vol. 379, iss. 1 Y1 - 1982 SN - 1873-1554 (E-Journal); 0375-9474 (Print) SP - 93 EP - 109 ER - TY - JOUR A1 - Martin, Siegfried A. A1 - Hardt, Arno A1 - Meissburger, Jürgen A1 - Berg, Georg P. A. A1 - Hacker, Ulrich A1 - Hürlimann, Werner A1 - Römer, Josef G. M. A1 - Sagefka, Thomas A1 - Retz, Adolf A1 - Schult, Otto W. B. T1 - The QQDDQ magnet spectrometer “BIG KARL” JF - Nuclear instruments and methods in physics research. Vol. 214, iss. 2-3 Y1 - 1983 SN - 0029-554x (E-Journal); 1872-9606 (E-Journal); 0167-5087 (Print) SP - 281 EP - 303 ER - TY - JOUR A1 - Martin, S. A. A1 - Berg, G. P. A. A1 - Hacker, U. A1 - Hardt, Arno A1 - Köhler, M. A1 - Meißburger, J. A1 - Osterfeld, F. A1 - Prasuhn, D. A1 - Riepe, G. A1 - Rogge, M. A1 - Schult, O. W. B. A1 - Speth, J. A1 - Turek, P. A1 - Gaul, G. A1 - Hagedoorn, H. A1 - Heide, J. A. van der A1 - Hinterberger, F. A1 - Huber, M. A1 - Jahn, R. A1 - Mayer-Kuckuk, T. A1 - Poth, H. A1 - Paetz gen. Schieck, H. T1 - COSY - a cooler synchrotron and storage ring JF - IEEE transactions on nuclear science. Vol. 32, iss. 5 Y1 - 1985 SN - 1558-1578 (E-Journal); 0018-9499 (Print) SP - 2694 EP - 2696 ER - TY - JOUR A1 - Bechstedt, U. A1 - Haas, H. A1 - Hacker, U. A1 - Hardt, Arno A1 - Henn, K. A1 - Martin, S. A1 - Wimmer, J. T1 - Magnets for the German Spallation Source SNQ JF - IEEE transactions on nuclear science. Vol. 32, iss. 5 Y1 - 1985 SN - 1558-1578 (E-Journal); 0018-9499 (Print) SP - 3631 EP - 3633 ER - TY - JOUR A1 - Makovicka, C. A1 - Gärtner, G. A1 - Hardt, Arno A1 - Hermann, W. A1 - Wiechert, D. U. T1 - Impregnated cathode surface investigations by SFM/STM and SEM/EDX JF - Applied surface science. Vol. 111 Y1 - 1997 SN - 1873-5584 (E-Journal); 0169-4332 (Print) SP - 70 EP - 75 ER - TY - JOUR A1 - Schult, O. W. B. A1 - Sistemich, K. A1 - Hardt, Arno T1 - Plans for investigations of subthreshold K+ production in p+A collisions / O. W. B. Schult [u.a.] JF - Nuclear Physics A. Vol. 583 Y1 - 1995 SN - 1873-1554 (E-journal); 0375-9474 (Print) SP - 629 EP - 632 ER - TY - JOUR A1 - Balewski, J. A1 - Brauksiepe, S. A1 - Hardt, Arno T1 - Threshold measurements at the internal experimental facility COSY-11 / J. Balewski [u.a.] JF - Nuclear physics A. Vol. 626, iss. 1-2 Y1 - 1997 SN - 1873-1554 (E-Journal) ; 0375-9474 (Print) SP - 85 EP - 92 ER - TY - JOUR A1 - Barsov, S. A1 - Bechstedt, U. A1 - Hardt, Arno T1 - ANKE, a new facility for medium energy hadron physics at COSY-Jülich / S. Barsov [u.a.] JF - Nuclear instruments and methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. Vol. 462, iss. 3 Y1 - 2001 SN - 0167-5087 (Print) ; 0168-9002 (E-journal) SP - 364 EP - 381 ER - TY - JOUR A1 - Murib, M. S. A1 - Grinsven, B. van A1 - Grieten, L. A1 - Janssens, S. D. A1 - Vermeeren, V. A1 - Eersels, K. A1 - Broeders, J. A1 - Ameloot, M. A1 - Michiels, L. A1 - Ceuninck, W. De A1 - Haenen, K. A1 - Schöning, Michael Josef A1 - Wagner, Patrick T1 - Electronic monitoring of chemical DNA denaturation on nanocrystalline diamond electrodes with different molarities and flow rates JF - Physica Status Solidi (A). Vol. 210 (2013), iss. 5 Y1 - 2013 SN - 0031-8965 SP - 911 EP - 917 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Huck, Christina A1 - Schiffels, Johannes A1 - Herrera, Cony N. A1 - Schelden, Maximilian A1 - Selmer, Thorsten A1 - Poghossian, Arshak A1 - Baumann, Marcus A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Metabolic responses of Escherichia coli upon glucose pulses captured by a capacitive field-effect sensor JF - Physica Status Solidi (A) N2 - Living cells are complex biological systems transforming metabolites taken up from the surrounding medium. Monitoring the responses of such cells to certain substrate concentrations is a challenging task and offers possibilities to gain insight into the vitality of a community influenced by the growth environment. Cell-based sensors represent a promising platform for monitoring the metabolic activity and thus, the “welfare” of relevant organisms. In the present study, metabolic responses of the model bacterium Escherichia coli in suspension, layered onto a capacitive field-effect structure, were examined to pulses of glucose in the concentration range between 0.05 and 2 mM. It was found that acidification of the surrounding medium takes place immediately after glucose addition and follows Michaelis–Menten kinetic behavior as a function of the glucose concentration. In future, the presented setup can, therefore, be used to study substrate specificities on the enzymatic level and may as well be used to perform investigations of more complex metabolic responses. Conclusions and perspectives highlighting this system are discussed. Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200900 SN - 0031-8965 VL - 210 IS - 5 SP - 926 EP - 931 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Schusser, Sebastian A1 - Leinhos, Marcel A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers JF - Physica Status Solidi (A) N2 - Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution. Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200941 SN - 1521-396X ; 0031-8965 VL - 210 IS - 5 SP - 905 EP - 910 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Poghossian, Arshak A1 - Weil, M. A1 - Cherstvy, A. G. A1 - Schöning, Michael Josef T1 - Electrical monitoring of polyelectrolyte multilayer formation by means of capacitive field-effect devices JF - Analytical and bioanalytical chemistry N2 - The semiconductor field-effect platform represents a powerful tool for detecting the adsorption and binding of charged macromolecules with direct electrical readout. In this work, a capacitive electrolyte–insulator–semiconductor (EIS) field-effect sensor consisting of an Al-p-Si-SiO2 structure has been applied for real-time in situ electrical monitoring of the layer-by-layer formation of polyelectrolyte (PE) multilayers (PEM). The PEMs were deposited directly onto the SiO2 surface without any precursor layer or drying procedures. Anionic poly(sodium 4-styrene sulfonate) and cationic weak polyelectrolyte poly(allylamine hydrochloride) have been chosen as a model system. The effect of the ionic strength of the solution, polyelectrolyte concentration, number and polarity of the PE layers on the characteristics of the PEM-modified EIS sensors have been studied by means of capacitance–voltage and constant-capacitance methods. In addition, the thickness, surface morphology, roughness and wettabilityof the PE mono- and multilayers have been characterised by ellipsometry, atomic force microscopy and water contact-angle methods, respectively. To explain potential oscillations on the gate surface and signal behaviour of the capacitive field-effect EIS sensor modified with a PEM, a simplified electrostatic model that takes into account the reduced electrostatic screening of PE charges by mobile ions within the PEM has been proposed and discussed. Y1 - 2013 U6 - https://doi.org/10.1007/s00216-013-6951-9 SN - 1432-1130 ; 1618-2642 VL - 405 IS - 20 SP - 6425 EP - 6436 PB - Springer CY - Berlin ER - TY - JOUR A1 - Werner, Frederik A1 - Wagner, Torsten A1 - Yoshinobu, Tatsuo A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Frequency behaviour of light-addressable potentiometric sensors JF - Physica Status Solidi (A) N2 - Light-addressable potentiometric sensors (LAPS) are semiconductor-based potentiometric sensors, with the advantage to detect the concentration of a chemical species in a liquid solution above the sensor surface in a spatially resolved manner. The addressing is achieved by a modulated and focused light source illuminating the semiconductor and generating a concentration-depending photocurrent. This work introduces a LAPS set-up that is able to monitor the electrical impedance in addition to the photocurrent. The impedance spectra of a LAPS structure, with and without illumination, as well as the frequency behaviour of the LAPS measurement are investigated. The measurements are supported by electrical equivalent circuits to explain the impedance and the LAPS-frequency behaviour. The work investigates the influence of different parameters on the frequency behaviour of the LAPS. Furthermore, the phase shift of the photocurrent, the influence of the surface potential as well as the changes of the sensor impedance will be discussed. Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200929 SN - 1521-396X ; 0031-8965 VL - 210 IS - 5 SP - 884 EP - 891 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Lindemann, Markus A1 - Runge, Alexander T1 - Permanent IT-support in electronic commerce transactions JF - Electronic markets : the international journal of networked business. Vol. 7 (1997), iss. 1 Y1 - 1997 SN - 1422-8890 SP - 18 EP - 20 ER - TY - JOUR A1 - Lindemann, Markus A1 - Schmid, Beat F. T1 - Framework for specifying, building and operating electronic markets JF - International journal of electronic commerce. Vol. 3 (1998/99), No. 2 Y1 - 1999 SN - 1086-4415 SP - 7 EP - 21 ER - TY - JOUR A1 - Palmer, J. W. A1 - Lindemann, Markus T1 - Business models and market mechanisms : evaluating efficiency in consumer electronic markets JF - Data base and advanced information systems. Bd. 34 (2003), H. 2 Y1 - 2003 SN - 0105-9912 SP - 23 EP - 38 ER - TY - JOUR A1 - Fischer, W. A. A1 - Dören, Horst-Peter A1 - Janke, Dieter T1 - Aluminium nitride probes for application in iron melts JF - Archiv für das Eisenhüttenwesen. 52 (1981), H. 3 Y1 - 1981 SN - 0003-8962 SP - 91 EP - 98 ER - TY - JOUR A1 - Itabashi, Akinori A1 - Kosaka, Naoki A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - High-speed chemical imaging system based on front-side-illuminated LAPS JF - Sensors and actuators B: Chemical N2 - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of specific ions on the sensing surface. The conventional chemical imaging system based on the light-addressable potentiometric sensor (LAPS), however, required a long time to obtain a chemical image, due to the slow mechanical scan of a single light beam. For high-speed imaging, a plurality of light beams modulated at different frequencies can be employed to measure the ion concentrations simultaneously at different locations on the sensor plate by frequency division multiplex (FDM). However, the conventional measurement geometry of back-side illumination limited the bandwidth of the modulation frequency required for FDM measurement, because of the low-pass filtering characteristics of carrier diffusion in the Si substrate. In this study, a high-speed chemical imaging system based on front-side-illuminated LAPS was developed, which achieved high-speed spatiotemporal recording of pH change at a rate of 70 frames per second. Y1 - 2013 U6 - https://doi.org/10.1016/j.snb.2013.03.016 SN - 1873-3077 VL - 182 SP - 315 EP - 321 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Feucht, Nikolaus A1 - Schönbach, Etienne Michael A1 - Lanzl, Ines A1 - Kotliar, Konstantin A1 - Lohmann, Chris Patrick A1 - Maier, Mathias T1 - Changes in the foveal microstructure after intravitreal bevacizumab application in patients with retinal vascular disease JF - Clinical Ophthalmology Y1 - 2013 SN - 1177-5483 VL - 7 SP - 173 EP - 178 PB - Dove Medical Press CY - Auckland, New Zealand ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Hanssen, Henner A1 - Eberhardt, Karla A1 - Vilser, Walthard A1 - Schmaderer, Christoph A1 - Halle, Martin A1 - Heemann, Uwe A1 - Baumann, M. T1 - Retinal pulse wave velocity in young male normotensive and mildly hypertensive subjects JF - Microcirculation Y1 - 2013 SN - 1549-8719 N1 - Accepted Article (Accepted, unedited articles published online and citable. The final edited and typeset version of record will appear in future.) PB - Wiley CY - Malden ER - TY - JOUR A1 - Reisert, Steffen A1 - Schneider, Benno A1 - Geissler, Hanno A1 - Gompel, Matthias van A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Multi-sensor chip for the investigation of different types of metal oxides for the detection of H2O2 in the ppm range JF - physica status solidi (a) N2 - In this work, a multi-sensor chip for the investigation of the sensing properties of different types of metal oxides towards hydrogen peroxide in the ppm range is presented. The fabrication process and physical characterization of the multi-sensor chip are described. Pure SnO2 and WO3 as well as Pd- and Pt-doped SnO2 films are characterized in terms of their sensitivity to H2O2. The sensing films have been prepared by drop-coating of water-dispensed nano-powders. A physical characterization, including scanning electron microscopy and X-ray diffraction analysis of the deposited metal-oxide films, was done. From the measurements in hydrogen peroxide atmosphere, it could be shown, that all of the tested metal oxide films are suitable for the detection of H2O2 in the ppm range. The highest sensitivity and reproducibility was achieved using Pt-doped SnO2. Calibration plot of a SnO2, WO3, Pt-, and Pd-doped SnO2 gas sensor for H2O2 concentrations in the ppm range. Y1 - 2013 SN - 1862-6319 VL - 210 IS - 5 SP - 898 EP - 904 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Hennemann, Jörg A1 - Kohl, Claus-Dieter A1 - Reisert, Steffen A1 - Kirchner, Patrick A1 - Schöning, Michael Josef T1 - Copper oxide nanofibres for detection of hydrogen peroxide vapour at high concentrations JF - physica status solidi (a) N2 - We present a sensor concept based on copper(II)oxide (CuO) nanofibres for the detection of hydrogen peroxide (H2O2) vapour in the percent per volume (% v/v) range. The fibres were produced by using the electrospinning technique. To avoid water condensation in the pores, the fibres were initially modified by an exposure to H2S to get an enclosed surface. By a thermal treatment at 350 °C the fibres were oxidised back to CuO. Thereby, the visible pores disappear which was verified by SEM analysis. The fibres show a decrease of resistance with increasing H2O2 concentration which is due to the fact that hydrogen peroxide is an oxidising gas and CuO a p-type semiconductor. The sensor shows a change of resistance within the minute range to the exposure until the maximum concentration of 6.9% v/v H2O2. At operating temperatures below 450 °C the corresponding sensor response to a concentration of 4.1% v/v increases. The sensor shows a good reproducibility of the signal at different measurements. CuO seems to be a suitable candidate for the detection of H2O2 vapour at high concentrations. Resistance behaviour of the sensor under exposure to H2O2 vapours between 2.3 and 6.9% v/v at an operating temperature of 450 °C. Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200775 SN - 1862-6319 VL - 210 IS - 5 SP - 859 EP - 863 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Nomdedeu, Mar Monsonis A1 - Willen, Christine A1 - Schieffer, Andre A1 - Arndt, Hartmut T1 - Temperature-dependent ranges of coexistence in a model of a two-prey-one-predator microbial food web JF - Marine Biology N2 - The objective of our study was to analyze the effects of temperature on the population dynamics of a three-species food web consisting of two prey bacteria (Pedobacter sp. and Acinetobacter johnsonii) and a protozoan predator (Tetrahymena pyriformis) as model organisms. We assessed the effects of temperature on the growth rates of all three species with the objective of developing a model with four differential equations based on the experimental data. The following hypotheses were tested at a theoretical level: Firstly, temperature changes can affect the dynamic behavior of a system by temperature-dependent parameters and interactions and secondly, food web response to temperature cannot be derived from the single species temperature response. The main outcome of the study is that temperature changes affect the parameter range where coexistence is possible within all three species. This has significant consequences on our ideas regarding the evaluation of effects of global warming. Y1 - 2012 U6 - https://doi.org/10.1007/s00227-012-1966-x SN - 1432-1793 VL - 159 IS - 11 SP - 2423 EP - 2430 PB - Springer CY - Berlin ER - TY - JOUR A1 - Heinzel, Alexander A1 - Schäfer, Ralf A1 - Müller, Hans-Wilhelm A1 - Schieffer, Andre A1 - Ingenhag, Ariane A1 - Northoff, Georg A1 - Franz, Matthias A1 - Hautzel, Hubertus T1 - Differential modulation of valence and arousal in high-alexithymic and low-alexithymic individuals JF - Neuroreport N2 - High-alexithymic individuals are characterized by an impaired ability to identify and communicate emotions whereas low-alexithymic individuals have a wide-ranging ability to deal with emotions. This study examined the hypothesis that valence and arousal modifications of emotional stimuli differentially modulate cortical regions in high-alexithymic and low-alexithymic individuals. To this end, 28 high-alexithymic and 25 low-alexithymic individuals were investigated with event-related fMRI using visual emotional stimuli. We found differential neural activations in the dorsal anterior cingulate, the insula and the amygdala. We suggest that these differences may account for the impaired ability of high-alexithymic individuals to appropriately handle emotional stimuli. Y1 - 2010 U6 - https://doi.org/10.1097/WNR.0b013e32833f38e0 SN - 1473-558X VL - 21 IS - 15 SP - 998 EP - 1002 PB - Lippincott Williams & Wilkins CY - London ER - TY - JOUR A1 - Heinzel, Alexander A1 - Schäfer, Ralf A1 - Müller, Hans-Wilhelm A1 - Schieffer, Andre A1 - Ingenhag, Ariane A1 - Eickhoff, Simon B. A1 - Northoff, Georg A1 - Franz, Matthias A1 - Hautzel, Hubertus T1 - Increased Activation of the Supragenual Anterior Cingulate Cortex during Visual Emotional Processing in Male Subjects with High Degrees of Alexithymia: An Event-Related fMRI Study JF - Psychotherapy and Psychosomatics N2 - Background: One of the most prominent neurobiological models of alexithymia assumes an altered function of the anterior cingulate cortex (ACC) as the crucial neural correlate of alexithymia. So far functional imaging studies have yielded inconclusive results. Therefore, we tested this hypothesis in healthy alexithymics and nonalexithymics in an event-related fMRI study. Methods: Thirty high- and 30 low-alexithymic right-handed male subjects (selected by the 20-item Toronto Alexithymia Scale, TAS-20) were investigated with event-related fMRI using a picture viewing paradigm. The stimuli consisted of happy, fearful and neutral facial expressions (Ekman-Friesen) as well as positive, negative and neutral pictures from the International Affective Picture System. Results: Contrasting the high-alexithymic with the low-alexithymic group we observed increased activation of the supragenual ACC for different emotional valences as well as for different emotional stimuli. Moreover, there was a positive correlation of the ACC with the individual TAS-20 scores but no correlations with the individual Beck Depression Inventory scores. Additionally, there was no difference in activity of the amygdala. Conclusions: We demonstrated that the supragenual ACC is constantly activated more strongly in alexithymic subjects and that this activation is related to the symptoms of alexithymia and not to associated symptoms such as depression. Therefore, our findings support the hypothesis of an altered function of the ACC in alexithymia. Y1 - 2010 U6 - https://doi.org/10.1159/000320121 SN - 0033-3190 VL - 79 IS - 6 SP - 363 EP - 370 PB - Karger CY - Basel ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Suso, Henri-Pierre A1 - Rysstad, Gunnar A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes JF - Physica status solidi (a) N2 - A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests. KW - calorimetric gas sensor;hydrogen peroxide;wireless sensor system Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200920 SN - 1862-6319 VL - 210 IS - 5 SP - 877 EP - 883 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Gebhardt, Andreas A1 - Fateri, Miranda T1 - 3D printing and its applications JF - RTejournal - Forum für Rapid Technologie N2 - Eine zunehmende Anzahl von Artikeln in Publikumszeitschriften und Journalen rückt die direkte Herstellung von Bauteilen und Figuren immer mehr in das Bewusstsein einer breiten Öffentlichkeit. Leider ergibt sich nur selten ein einigermaßen vollständiges Bild davon, wie und in welchen Lebensbereichen diese Techniken unseren Alltag verändern werden. Das liegt auch daran, dass die meisten Artikel sehr technisch geprägt sind und sich nur punktuell auf Beispiele stützen. Dieser Beitrag geht von den Bedürfnissen der Menschen aus, wie sie z.B. in der Maslow’schen Bedürfnispyramide strukturiert dargestellt sind und unterstreicht dadurch, dass 3D Printing (oder Additive Manufacturing resp. Rapid Prototyping) bereits alle Lebensbereiche erfasst hat und im Begriff ist, viele davon zu revolutionieren. N2 - An increasing amount of popular articles focus on making models and sculptures by 3D Printing thus making more and more even private users aware of this technology. Unfortunately they mostly draw an incomplete picture of how our daily life will be influenced by this new technology. Often this is caused by a very technical point of view based on not very representative examples. This article focuses on the peoples needs as they have been structured by the so-called Maslow pyramid. Doing so, it underlines that 3D Printing (called Additive Manufacturing or Rapid Prototyping as well) already touches all aspects of life and is about to revolutionize most of them. Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0009-2-35626 SN - 1614-0923 VL - 10 IS - 1 PB - Fachhochschule Aachen CY - Aachen ER - TY - JOUR A1 - Parl, C. A1 - Larue, H. A1 - Streun, M. A1 - Ziemons, Karl T1 - Double-side-readout technique for SiPM-matrices JF - 2010 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit. Y1 - 2011 SN - 1095-7863 SP - 1486 EP - 1487 PB - IEEE CY - New York ER - TY - JOUR A1 - Herzog, Hans A1 - Pietrzyk, Uwe A1 - Shah, N. Jon A1 - Ziemons, Karl T1 - The current state, challenges and perspectives of MR-PET JF - Neuroimage N2 - Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization. Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum Jülich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27–28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop. Y1 - 2010 U6 - https://doi.org/10.1016/j.neuroimage.2009.10.036 SN - 1053-8119 VL - 49 IS - 3 SP - 2072 EP - 2082 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Beer, S. A1 - Streun, M. A1 - Hombach, T. A1 - Buehler, J. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants JF - Physics in Medicine and Biology N2 - Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements. Y1 - 2010 U6 - https://doi.org/10.1088/0031-9155/55/3/006 SN - 1361-6560 VL - 55 IS - 3 SP - 635 EP - 646 PB - IOP CY - Bristol ER - TY - JOUR A1 - Streun, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - A compact PET detector readout using charge-to-time conversion JF - 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The readout of gamma detectors is considerably simplified when the event intensity is encoded as a pulse width (Pulse Width Modulation, PWM). Time-to-Digital-Converters (TDC) replace the conventional ADCs and multiple TDCs can be realized easily in one PLD chip (Programmable Logic Device). The output of a PWM stage is only one digital signal per channel which is well suited for transport so that further processing can be performed apart from the detector. This is particularly interesting for large systems with high channel density (e.g. high resolution scanners). In this work we present a circuit with a linear transfer function that requires a minimum of components by performing the PWM already in the preamp stage. This allows a very compact and also cost-efficient implementation of the front-end electronics. Y1 - 2009 SN - 1082-3654 SP - 1868 EP - 1870 PB - IEEE CY - New York ER - TY - JOUR A1 - Wedrowski, M. A1 - Bruyndonckx, P. A1 - Tavernier, S. A1 - Zhi, L. A1 - Dang, J. A1 - Mendes, P. R. A1 - Perez, J. M. A1 - Ziemons, Karl T1 - Robustness of neural networks algorithm for gamma detection in monolithic block detector, positron emission tomography JF - 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The monolithic scintillator block approach for gamma detection in the Positron Emission Tomography (PET) avoids estimating Depth of Interaction (DOI), reduces dead zones in detector and diminishes costs of detector production. Neural Networks (NN) are very efficient to determine the entrance point of a gamma incident on a scintillator block. This paper presents results on the robustness of the spatial resolution as a function of the random fraction in the data, temperature and HV fluctuations. This is important when implementing the method in a real scanner. Measurements were done with two Hamamatsu S8550 APD arrays, glued on a 20 × 20 × 10 mm3 monolithic LSO crystal block. Y1 - 2009 SN - 1082-3654 SP - 2625 EP - 2628 ER - TY - JOUR A1 - Jahnke, Siegfried A1 - Menzel, Marion I. A1 - Dusschoten, Dagmar van A1 - Roeb, Gerhard W. A1 - Bühler, Jonas A1 - Minwuyelet, Senay A1 - Blümler, Peter A1 - Temperton, Vicky M. A1 - Hombach, Thomas A1 - Streun, Matthias A1 - Beer, Simone A1 - Khodaverdi, Maryam A1 - Ziemons, Karl A1 - Coenen, Heinz H. A1 - Schurr, Ulrich T1 - Combined MRI–PET dissects dynamic changes in plant structures and functions JF - The Plant Journal N2 - Unravelling the factors determining the allocation of carbon to various plant organs is one of the great challenges of modern plant biology. Studying allocation under close to natural conditions requires non-invasive methods, which are now becoming available for measuring plants on a par with those developed for humans. By combining magnetic resonance imaging (MRI) and positron emission tomography (PET), we investigated three contrasting root/shoot systems growing in sand or soil, with respect to their structures, transport routes and the translocation dynamics of recently fixed photoassimilates labelled with the short-lived radioactive carbon isotope 11C. Storage organs of sugar beet (Beta vulgaris) and radish plants (Raphanus sativus) were assessed using MRI, providing images of the internal structures of the organs with high spatial resolution, and while species-specific transport sectoralities, properties of assimilate allocation and unloading characteristics were measured using PET. Growth and carbon allocation within complex root systems were monitored in maize plants (Zea mays), and the results may be used to identify factors affecting root growth in natural substrates or in competition with roots of other plants. MRI–PET co-registration opens the door for non-invasive analysis of plant structures and transport processes that may change in response to genomic, developmental or environmental challenges. It is our aim to make the methods applicable for quantitative analyses of plant traits in phenotyping as well as in understanding the dynamics of key processes that are essential to plant performance. Y1 - 2009 SN - 1365-313X VL - 59 IS - 4 SP - 634 EP - 644 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Alexopoulos, Spiros T1 - Biogas systems: basics, biogas multifunction, principle of fermentation and hybrid application with a solar tower for the treatment of waste animal manure JF - Journal of Engineering Science and Technology Review N2 - Two of the main environmental problems of today’s society are the continuously increasing production of organic wastes as well as the increase of carbon dioxide in the atmosphere and the related green house effect. A way to solve these problems is the production of biogas. Biogas is a combustible gas consisting of methane, carbon dioxide and small amounts of other gases and trace elements. Production of biogas through anaerobic digestion of animal manure and slurries as well as of a wide range of digestible organic wastes and agricultural residues, converts these substrates into electricity and heat and offers a natural fertiliser for agriculture. The microbiological process of decomposition of organic matter, in the absence of oxygen takes place in reactors, called digesters. Biogas can be used as a fuel in a gas turbine or burner and can be used in a hybrid solar tower system offering a solution for waste treatment of agricultural and animal residues. A solar tower system consists of a heliostat field, which concentrates direct solar irradiation on an open volumetric central receiver. The receiver heats up ambient air to temperatures of around 700°C. The hot air’s heat energy is transferred to a steam Rankine cycle in a heat recovery steam generator (HRSG). The steam drives a steam turbine, which in turn drives a generator for producing electricity. In order to increase the operational hours of a solar tower power plant, a heat storage system and/ or hybridization may be considered. The advantage of solar-fossil hybrid power plants, compared to solar-only systems, lies in low additional investment costs due to an adaptable solar share and reduced technical and economical risks. On sunny days the hybrid system operates in a solar-only mode with the central receiver and on cloudy days and at night with the gas turbine only. As an alternative to methane gas, environmentally neutral biogas can be used for operating the gas turbine. Hence, the hybrid system is operated to 100% from renewable energy sources Y1 - 2012 SN - 1791-2377 N1 - Special Issue on Renewable Energy Systems VL - 5 IS - 4 SP - 48 EP - 55 ER - TY - JOUR A1 - Helmig, Ilka T1 - Nitty - fontnames illustrated JF - Slanted KW - Illustration KW - Typographie Y1 - 2010 SN - 1867-6510 IS - 11 SP - 68 EP - 69 PB - Slanted Publishers CY - Karlsruhe ER - TY - JOUR A1 - Ziemons, Karl A1 - Bruyndonckx, P. A1 - Perez, J. M. A1 - Pietrzyk, U. A1 - Rato, P. A1 - Tavernier, S. T1 - Beyond ClearPET: Next Aims JF - 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro Symposium Proceedings ISBI 2008 N2 - The CRYSTAL CLEAR collaboration, in short CCC, is a consortium of 12 academic institutions, mainly from Europe, joining efforts in the area of developing instrumentation for nuclear medicine and medical imaging. In the framework of the CCC a high performance small animal PET system, called ClearPET, was developed by using new technologies in electronics and crystals in a phoswich arrangement combining two types of lutetium- based scintillator materials: LSO:Ce and LuYAP:Ce. Our next aim will be the development of hybrid image systems. Hybrid MR-PET imaging has many unique advantages for brain research. This has sparked a new research line within CCC for the development of novel MR-PET compatible technologies. MRI is not as sensitive as PET but PET has poorer spatial resolution than MRI. Two major advantages of PET are sensitivity and its ability to acquire metabolic information. To assess these innovations, the development of a 9.4T hybrid animal MR-PET scanner is proposed based on an existing 9.4T MR scanner that will be adapted to enable simultaneous acquisition of MR and PET data using cutting- edge technology for both MR and PET. Y1 - 2008 SN - 978-1-4244-2003-2 SP - 1421 EP - 1424 ER - TY - JOUR A1 - Streun, M. A1 - Beer, S. A1 - Hombach, T. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - PlanTIS: A positron emission tomograph for imaging 11C transport in plants JF - 2007 IEEE Nuclear Science Symposium Conference Record, Vol. 6 N2 - Plant growth and transport processes are highly dynamic. They are characterized by plant-internal control processes and by strong interactions with the spatially and temporally varying environment. Analysis of structure- function relations of growth and transport in plants will strongly benefit from the development of non-invasive techniques. PlanTIS (Plant Tomographic Imaging System) is designed for non-destructive 3D-imaging of positron emitting radiotracers. It will permit functional analysis of the dynamics of carbon distribution in plants including bulky organs. It will be applicable for screening transport properties of plants to evaluate e.g. temperature adaptation of genetically modified plants. PlanTIS is a PET scanner dedicated to monitor the dynamics of the 11C distribution within a plant while or after assimilation of 11CO2. Front end electronics and data acquisition architecture of the scanner are based on the ClearPETTM system [1]. Four detector modules form one of two opposing detector blocks. Optionally, a hardware coincidence detection between the blocks can be applied. In general the scan duration is rather long (~ 1 hour) compared to the decay time of 11C (20 min). As a result the count rates can vary over a wide range and accurate dead time correction is necessary. Y1 - 2008 SN - 1082-3654 SP - 4110 EP - 4112 ER - TY - JOUR A1 - Mosset, J.-B. A1 - Devroede, O. A1 - Krieguer, M. A1 - Rey, M. A1 - Vieira, J.-M. A1 - Jung, J. H. A1 - Kuntner, C. A1 - Streun, M. A1 - Ziemons, Karl A1 - Auffray, E. A1 - Sempere-Roldan, P. A1 - Lecoq, P. A1 - Bruyndonckx, P. A1 - Loude, J.-F. A1 - Tavernier, S. A1 - Morcel, C. T1 - Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator JF - IEEE Transactions on Nuclear Science N2 - This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 1 SP - 25 EP - 29 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Weber, S. A1 - Streun, M. A1 - Parl, C. A1 - Ziemons, Karl T1 - High resolution imaging with ClearPET™ Neuro - first animal images JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance. Y1 - 2006 SN - 1082-3654 SP - 1641 EP - 1644 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - Timemark correction for the ClearPET™ scanners JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented Y1 - 2006 SN - 1082-3654 SP - 2057 EP - 2060 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - The data acquisition system of ClearPET neuro - a small animal PET scanner JF - IEEE Transactions on Nuclear Science N2 - The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jülich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 3 SP - 700 EP - 703 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chatziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, U. T1 - Investigation of different MicroCT scanner configurations by GEANT4 simulations JF - IEEE Transactions on Nuclear Science N2 - This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2005 SN - 0018-9499 VL - 52 IS - 1 SP - 188 EP - 192 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. A1 - Bruyndonckx, P. T1 - The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Second generation high-performance PET scanners, called ClearPET™1, have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and high spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8×8 crystals of 2×2×10 mm3 are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm.The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time, which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view. Preliminary data shows a correct identification of the crystal layer about (98±1)%. Typically the energy resolution is (23.3±0.5)% for the luyap layer and (15.4±0.4)% for the lso layer. early studies showed the timing resolution of 2 ns FWHM and 4.8 ns FWTM. the intrinsic spatial resolution ranges from 1.37 mm to 1.61 mm full-width of half-maximum (FWHM) with a mean of 1.48 mm FWHM. further improvements in image and energy resolution are expected when the system geometry is fully modeled. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 307 EP - 311 ER - TY - JOUR A1 - Streun, M. A1 - Christ, D. A1 - Hellendung, A. A1 - Larue, H. A1 - Ziemons, Karl A1 - Halling, H. T1 - Effects of crosstalk and gain nonuniformity using multichannel PMTs in the Clearpet® scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The ClearPET® scanners developed by the Crystal Clear Collaboration use multichannel PMTs as photodetectors with scintillator pixels coupled individually to each channel. In order to localize an event each channel anode is connected to a comparator that triggers when the anode signal exceeds a common predefined threshold. Two major difficulties here are crosstalk of light and the gain nonuniformity of the PMT channels. Crosstalk can generate false triggering in channels adjacent to the actual event. On the one hand this can be suppressed by sufficiently increasing the threshold, but on the other hand a threshold too high can already prevent valid events on the lower gain channels from being detected. Finally, both effects restrict the dynamic range of pulse heights that can be processed. The requirements to the dynamic range are not low as the ClearPET® scanners detect the depth of interaction by phoswich pixels consisting of LSO and Lu0.7Y0.3AP, two scintillators with different light yields. We will present a model to estimate the achievable dynamic range and show solutions to increase it. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 402 EP - 405 ER - TY - JOUR A1 - Auffray, E. A1 - Bruyndonckx, P. A1 - Devroede, O. A1 - Fedorov, A. A1 - Ziemons, Karl T1 - The ClearPET project JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9% for a point source in the centre of the field of view. Y1 - 2004 SN - 0168-9002 N1 - Proceedings of the 2nd International Conference on Imaging Technologies in Biomedical Sciences VL - 527 IS - 1-2 SP - 171 EP - 174 ER - TY - JOUR A1 - Ziemons, Karl A1 - Heinrichs, U. A1 - Streun, M. A1 - Pietrzyk, U. T1 - Validation of GEANT3 simulation studies with a dual-head PMT ClearPET™ prototype JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry. Y1 - 2004 SN - 1082-3654 SP - 3053 EP - 3056 ER - TY - JOUR A1 - Christ, D. A1 - Hollendung, A. A1 - Larue, H. A1 - Parl, C. A1 - Streun, M. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. T1 - Homogenization of the MultiChannel PM gain by inserting light attenuating masks JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - MultiChannel Photomultipliers (PM), like the R7600-00-M64 or R5900-00-M64 from Hamamatsu, are often chosen as photodetectors in high-resolution positron emission tomography (PET). A major problem of this PM is the nonuniform channel gain. In order to solve this problem, light attenuating masks were created. The aim of the masks is a homogenization of the output of all 64 channels using different hole sizes at the channel positions. The hole area, which is individually defined for the different channels, is inversely proportional to the channel gain. The measurements by inserting light attenuating masks improved a homogenization to a ratio of 1:1.2. Y1 - 2004 SN - 1082-3654 SP - 2382 EP - 2385 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Brökel, M. A1 - Fuss, L. A1 - Larue, H. A1 - Parl, C. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - The ClearPET data acquisition JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - Within the Crystal Clear Collaboration a modular system for a small animal PET scanner (ClearPET™) has been developed. The modularity allows the assembly of scanners of different sizes and characteristics in order to fit the specific needs of the individual member institutions. Now a first demonstrator is being completed in Julich. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to multi-channel photomultipliers (PMTs). A free-running ADC digitizes the signal from the PMT and the complete scintillation pulses are sampled by an FPGA and sent with 20 MB/S to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. An advantage of that is that the coincidence window and the dimensions of the field of view can be adjusted easily. The ClearPET™ demonstrator is equipped with 10240 crystals on 80 PMTs. This paper presents an overview of the data acquisition system. Y1 - 2004 SN - 1082-3654 SP - 3097 EP - 3100 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. T1 - The ClearPET TM LSO/LuYAP phoswich scanner: a high performance small animal PET system JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes. Y1 - 2004 SN - 1082-3654 SP - 1728 EP - 1732 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chaziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, U. T1 - Investigation of different microCT scanner configurations by GEANT4 simulations JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - This study has been performed to design the combination of the new ClearPET TM (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal Positron Emission Tomography (PET) system, with a microComputed Tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2004 SN - 1082-3654 SP - 2989 EP - 2993 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - IEEE Transactions on Nuclear Science N2 - A feasible way to gain the depth of interaction information in a positron emission tomography scanner is the use of phoswich detectors. In general, the layer of interaction is identified from the pulse shape of the corresponding scintillator material. In this work, pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could be kept simple because of an additional slow component in the light decay of the LuYAP pulse. At the same time, the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 3 SP - 344 EP - 347 ER -