TY - JOUR A1 - Zhen, Manghao A1 - Liang, Yunpei A1 - Staat, Manfred A1 - Li, Quanqui A1 - Li, Jianbo T1 - Discontinuous fracture behaviors and constitutive model of sandstone specimens containing non-parallel prefabricated fissures under uniaxial compression JF - Theoretical and Applied Fracture Mechanics N2 - The deformation and damage laws of non-homogeneous irregular structural planes in rocks are the basis for studying the stability of rock engineering. To investigate the damage characteristics of rock containing non-parallel fissures, uniaxial compression tests and numerical simulations were conducted on sandstone specimens containing three non-parallel fissures inclined at 0°, 45° and 90° in this study. The characteristics of crack initiation and crack evolution of fissures with different inclinations were analyzed. A constitutive model for the discontinuous fractures of fissured sandstone was proposed. The results show that the fracture behaviors of fissured sandstone specimens are discontinuous. The stress–strain curves are non-smooth and can be divided into nonlinear crack closure stage, linear elastic stage, plastic stage and brittle failure stage, of which the plastic stage contains discontinuous stress drops. During the uniaxial compression test, the middle or ends of 0° fissures were the first to crack compared to 45° and 90° fissures. The end with small distance between 0° and 45° fissures cracked first, and the end with large distance cracked later. After the final failure, 0° fissures in all specimens were fractured, while 45° and 90° fissures were not necessarily fractured. Numerical simulation results show that the concentration of compressive stress at the tips of 0°, 45° and 90° fissures, as well as the concentration of tensile stress on both sides, decreased with the increase of the inclination angle. A constitutive model for the discontinuous fractures of fissured sandstone specimens was derived by combining the logistic model and damage mechanic theory. This model can well describe the discontinuous drops of stress and agrees well with the whole processes of the stress–strain curves of the fissured sandstone specimens. KW - Constitutive model KW - Damage mechanics theory KW - Discontinuous fractures KW - Uniaxial compression test KW - Non-parallel fissures Y1 - 2024 U6 - http://dx.doi.org/10.1016/j.tafmec.2024.104373 SN - 0167-8442 VL - 131 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Wegmann, Kilian A1 - Hackl, Michael A1 - Staat, Manfred A1 - Mayer, Katharina A1 - Müller, Lars-Peter T1 - Double plate osteosynthesis of proximal ulna fractures: biomechanical and clinical results JF - Knee surgery, sports traumatology, arthroscopy N2 - While plate fixation of proximal ulna fractures might lead to superior clinical results compared to tension band wiring, regular plates represent an established risk factor for wound complications. The olecranon double plates (Medartis, Basel, CH) might decrease complications related to the osteosynthesis because of their low profile and better anatomical fit. This study aimed to evaluate the biomechanical performance and clinical results of the olecranon double plates. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4079-0 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 58 EP - 59 PB - Springer CY - Berlin ER - TY - JOUR A1 - Vu, Duc-Khoi A1 - Staat, Manfred T1 - An algorithm for shakedown analysis of structure with temperature dependent yield stress N2 - This work is an attempt to answer the question: How to use convex programming in shakedown analysis of structures made of materials with temperature-dependent properties. Based on recently established shakedown theorems and formulations, a dual relationship between upper and lower bounds of the shakedown limit load is found, an algorithmfor shakedown analysis is proposed. While the original problem is neither convex nor concave, the algorithm presented here has the advantage of employing convex programming tools. KW - Einspielen KW - Temperaturabhängigkeit KW - Fließgrenze KW - Shakedown KW - shakedown analysis KW - yield stress Y1 - 2004 ER - TY - JOUR A1 - Vu, Duc Khoi A1 - Staat, Manfred A1 - Tran, Ich Thinh T1 - Analysis of pressure equipment by application of the primal-dual theory of shakedown JF - Communications in Numerical Methods in Engineering. 23 (2007), H. 3 Y1 - 2007 SN - 1069-8299 SP - 213 EP - 225 ER - TY - JOUR A1 - Vu, Duc Khoi A1 - Staat, Manfred T1 - Shakedown analysis of structures made of materials with temperature-dependent yield stress JF - International Journal of Solids and Structures. 44 (2007), H. 13 Y1 - 2007 SN - 0020-7683 SP - 4524 EP - 4540 ER - TY - JOUR A1 - Vant, Christianne A1 - Staat, Manfred A1 - Baroud, Gamal T1 - Percutaneous Vertebroplasty: A Review of Two Intraoperative Complications JF - Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.) Y1 - 2008 SN - 978-3-540-75408-4 SP - 527 EP - 539 PB - Springer CY - Berlin ER - TY - JOUR A1 - Ullrich, Sebastian A1 - Grottke, Oliver A1 - Rossaint, Rolf A1 - Staat, Manfred A1 - Deserno, Thomas M. A1 - Kuhlen, Torsten T1 - Virtual Needle Simulation with Haptics for Regional Anaesthesia Y1 - 2010 N1 - IEEE Virtual Reality 2010, Workshop on Medical Virtual Environments, Waltham, MA, USA, March 21, 2010 SP - 1 EP - 3 ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 7 ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - An Edge-Based Smoothed Finite Element Method for Primal-Dual Shakedown Analysis of Structures Under Uncertainties JF - Limit State of Materials and Structures : Direct Methods 2. Saxcé, Géry de (Hrsg.) Y1 - 2013 SN - 978-94-007-5424-9 SP - 89 EP - 102 PB - Springer CY - Dordrecht ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Pham, Phu Tinh A1 - Vu, D. K. A1 - Staat, Manfred T1 - Reliability Analysis of Inelastic Shell Structures Under Variable Loads JF - Limit States of Materials and Structures : Direct Methods / Hrsg. Dieter Weichert; Hrsg. Alan Ponter Y1 - 2009 SN - 978-1-4020-9633-4 SP - 135 EP - 156 PB - Springer Netherland CY - Berlin ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Kreißig, R. A1 - Vu, Duc Khoi A1 - Staat, Manfred T1 - Upper bound limit and shakedown analysis of shells using the exact Ilyushin yield surface JF - Computer & Structures. 86 (2008) Y1 - 2008 SN - 0045-7949 SP - 1683 EP - 1695 ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Kreißig, R. A1 - Staat, Manfred T1 - Probabilistic limit and shakedown analysis of thin plates and shells JF - Structural safety. 31 (2009), H. 1 Y1 - 2009 SN - 0167-4730 SP - 1 EP - 18 PB - - ER - TY - JOUR A1 - Tran, Ngoc Trinh A1 - Trinh, Tu Luc A1 - Dao, Ngoc Tien A1 - Giap, Van Tan A1 - Truong, Manh Khuyen A1 - Dinh, Thuy Ha A1 - Staat, Manfred T1 - FEM shakedown analysis of structures under random strength with chance constrained programming JF - Vietnam Journal of Mechanics N2 - Direct methods, comprising limit and shakedown analysis, are a branch of computational mechanics. They play a significant role in mechanical and civil engineering design. The concept of direct methods aims to determine the ultimate load carrying capacity of structures beyond the elastic range. In practical problems, the direct methods lead to nonlinear convex optimization problems with a large number of variables and constraints. If strength and loading are random quantities, the shakedown analysis can be formulated as stochastic programming problem. In this paper, a method called chance constrained programming is presented, which is an effective method of stochastic programming to solve shakedown analysis problems under random conditions of strength. In this study, the loading is deterministic, and the strength is a normally or lognormally distributed variable. KW - limit analysis KW - shakedown analysis KW - chance constrained programming KW - stochastic programming KW - reliability of structures Y1 - 2022 U6 - http://dx.doi.org/10.15625/0866-7136/17943 SN - 0866-7136 SN - 2815-5882 VL - 44 IS - 4 SP - 459 EP - 473 PB - Vietnam Academy of Science and Technology (VAST) ER - TY - JOUR A1 - Tran, Ngoc Trinh A1 - Staat, Manfred T1 - Direct plastic structural design under lognormally distributed strength by chance constrained programming JF - Optimization and Engineering N2 - We propose the so-called chance constrained programming model of stochastic programming theory to analyze limit and shakedown loads of structures under random strength with a lognormal distribution. A dual chance constrained programming algorithm is developed to calculate simultaneously both the upper and lower bounds of the plastic collapse limit and the shakedown limit. The edge-based smoothed finite element method (ES-FEM) is used with three-node linear triangular elements. Y1 - 2020 U6 - http://dx.doi.org/10.1007/s11081-019-09437-2 SN - 1573-2924 VL - 21 IS - 1 SP - 131 EP - 157 PB - Springer Nature CY - Cham ER - TY - JOUR A1 - Tran, Ngoc Trinh A1 - Staat, Manfred T1 - Direct plastic structural design under random strength and random load by chance constrained programming JF - European Journal of Mechanics - A/Solids Y1 - 2021 U6 - http://dx.doi.org/10.1016/j.euromechsol.2020.104106 SN - 0997-7538 VL - 85 IS - Article 104106 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Topçu, Murat A1 - Madabhushi, Gopal S.P. A1 - Staat, Manfred T1 - A generalized shear-lag theory for elastic stress transfer between matrix and fibres having a variable radius JF - International Journal of Solids and Structures N2 - A generalized shear-lag theory for fibres with variable radius is developed to analyse elastic fibre/matrix stress transfer. The theory accounts for the reinforcement of biological composites, such as soft tissue and bone tissue, as well as for the reinforcement of technical composite materials, such as fibre-reinforced polymers (FRP). The original shear-lag theory proposed by Cox in 1952 is generalized for fibres with variable radius and with symmetric and asymmetric ends. Analytical solutions are derived for the distribution of axial and interfacial shear stress in cylindrical and elliptical fibres, as well as conical and paraboloidal fibres with asymmetric ends. Additionally, the distribution of axial and interfacial shear stress for conical and paraboloidal fibres with symmetric ends are numerically predicted. The results are compared with solutions from axisymmetric finite element models. A parameter study is performed, to investigate the suitability of alternative fibre geometries for use in FRP. KW - Natural fibres KW - Polymer-matrix composites KW - Biocomposites KW - Stress concentrations KW - Finite element analysis Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.ijsolstr.2022.111464 SN - 0020-7683 VL - 239–240 IS - Art. No. 111464 PB - Elsevier CY - New York, NY ER - TY - JOUR A1 - Staat, Manfred A1 - Wolters, J A1 - Bongarts, W. A1 - Hennings, W. (u.a.) T1 - Überarbeitete probabilistisch orientierte Sicherheitsanalyse für den HTR-Modul JF - Jahrestagung Kerntechnik '90 / Kerntechnische Gesellschaft e.V. ; Deutsches Atomforum e.V Y1 - 1990 SP - 143 EP - 146 PB - INFORUM CY - Bonn ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Khoi Duc T1 - Limit loads of circumferentially flawed pipes and cylindrical vessels under internal pressure JF - International Journal of Pressure Vessels and Piping. 83 (2006), H. 3 Y1 - 2006 SN - 0308-0161 SP - 188 EP - 196 ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Duc-Khoi T1 - An Algorithm for Shakedown Analysis for Materials with Temperature Dependent Yield Stress JF - Proceedings in Applied Mathematics and Mechanics (PAMM). 4 (2004), H. 1 Y1 - 2004 SN - 1617-7061 SP - 231 EP - 233 ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Duc-Khoi T1 - Limit analysis of flaws in pressurized pipes and cylindrical vessels. Part I: Axial defects JF - Engineering Fracture Mechanics. 74 (2007), H. 3 Y1 - 2007 SN - 0013-7944 SP - 431 EP - 450 ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Duc Khoi T1 - Limit analysis of flaws in pressurized pipes and cylindrical vessels Part II: Circumferential defects JF - Engineering Fracture Mechanics ; 97(2013), H. 1 N2 - Upper and lower bound theorems of limit analyses have been presented in part I of the paper. Part II starts with the finite element discretization of these theorems and demonstrates how both can be combined in a primal–dual optimization problem. This recently proposed numerical method is used to guide the development of a new class of closed-form limit loads for circumferential defects, which show that only large defects contribute to plastic collapse with a rapid loss of strength with increasing crack sizes. The formulae are compared with primal–dual FEM limit analyses and with burst tests. Even closer predictions are obtained with iterative limit load solutions for the von Mises yield function and for the Tresca yield function. Pressure loading of the faces of interior cracks in thick pipes reduces the collapse load of circumferential defects more than for axial flaws. Axial defects have been treated in part I of the paper. Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.engfracmech.2012.05.017 SN - 0013-7944 VL - 97 SP - 314 EP - 333 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Staat, Manfred A1 - Trenz, Eva A1 - Lohmann, Philipp A1 - Frotscher, Ralf A1 - Klinge, Uwe A1 - Tabaza, Ruth A1 - Kirschner-Hermanns, Ruth T1 - New measurements to compare soft tissue anchoring systems in pelvic floor surgery JF - Journal of Biomedical Materials Research Part B: Applied Biomaterials N2 - Suburethral slings as well as different meshes are widely used treating stress urinary incontinence and prolaps in women. With the development of MiniSlings and special meshes using less alloplastic material anchorage systems become more important to keep devices in place and to put some tension especially on the MiniSlings. To date, there are many different systems of MiniSlings of different companies on the market which differ in the structure of the used meshes and anchors. A new objective measurement method to compare different properties of MiniSling systems (mesh and anchor) is presented in this article. Ballistic gelatine acts as soft tissue surrogate. Significant differences in parameters like pull-out strength of anchors or shrinkage of meshes under loading conditions have been determined. The form and size of the anchors as well as the structural stability of the meshes are decisive for a proper integration. The tested anchorings sytems showed markedly different mechanical function at their respective load bearing capacity. As the stable fixation of the device in tissue is a prerequisite for a permanet reinforcement, the proposed test system permits further optimisation of anchor and mesh devices to improve the success of the surgical treatment Y1 - 2012 U6 - http://dx.doi.org/10.1002/jbm.b.32654 SN - 1552-4981 VL - 100B IS - 4 SP - 924 EP - 933 PB - Wiley CY - Hoboken, NJ ER - TY - JOUR A1 - Staat, Manfred A1 - Tran, Thanh Ngoc A1 - Kreißig, R. T1 - Load bearing capacity of thin shell structures made of elastoplastic material by direct methods JF - Technische Mechanik. 28 (2008), H. 3-4 Y1 - 2008 SP - 299 EP - 309 ER - TY - JOUR A1 - Staat, Manfred A1 - Sponagel, Stefan A1 - Nguyen, Nhu Huynh T1 - Experiment and material model for soft tissue materials JF - Constitutive models for rubber VI : proceedings of the sixth European Conference on Constitutive Models for Rubber, Dresden, Germany, 7 - 10 September 2009 / eds. Gert Heinrich ... Y1 - 2010 SN - 978-0-415-56327-7 SP - 465 EP - 470 PB - CRC Press CY - Boca Raton [u.a.] ER - TY - JOUR A1 - Staat, Manfred A1 - Schwartz, M. A1 - Lang, H. A1 - Wirtz, K. A1 - Heitzer, M. T1 - Design by Analysis of Pressure Components by non-linear Optimization JF - The 10th International Conference on Pressure Vessel Technology, July 7-10, 2003, Vienna, Austria, Proceedings ICPVT-10 / Zeman, J. L. [ed] Y1 - 2003 SN - 3950152814 SP - 59 EP - 65 PB - ÖGS, Österreichische Gesellschaft für Schweißtechnik CY - Wien ER - TY - JOUR A1 - Staat, Manfred A1 - Kühn, R. A1 - Hauger, W. A1 - Sponagel, Stefan T1 - An Interpretation of Wolff’s Law JF - Biomedizinische Technik. 49 (2004) Y1 - 2004 SN - 0932-4666 N1 - Ergänzungsband 2, Teil 2 SP - 1020 EP - 1021 ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. A1 - Reiners, H. A1 - Schubert, F. T1 - Shakedown and ratchetting under tension–torsion loadings: analysis and experiments JF - Nuclear Engineering and Design. 225 (2003), H. 1 Y1 - 2003 SN - 0029-5493 SP - 11 EP - 26 ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. A1 - Lang, H. A1 - Wirtz, K. T1 - Direct Finite Element Route for Design-by-Analysis of Pressure Components JF - International Journal of Pressure Vessels and Piping. 82 (2005), H. 1 Y1 - 2005 SN - 0308-0161 SP - 61 EP - 67 ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. A1 - Hicken, E.F. T1 - LISA, ein europäisches Projekt zur direkten Berechnung der Tragfähigkeit duktiler Strukturen. Y1 - 1998 N1 - PERMAS–Benutzertagung, 8.–9.10.1998, Stuttgart (1998) ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Limit and Shakedown Analysis for Plastic Safety of Complex Structures JF - Transactions of the 14th International Conference on Structural Dynamics in Reactor Technology (SMiRT-14) / Livolant, M. [ed] Y1 - 1997 N1 - Vol. B, Paper B02/2 SP - 33 EP - 40 CY - Lyon ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Limit and Shakedown Analysis Using a General Purpose Finite Element Code JF - Proceedings of NAFEMS World Congress '97 on Design, Simulation & Optimisation : reliability & applicability of computational methods ; Stuttgart, Germany, 9 - 11 April 1997 Y1 - 1997 SN - 1-87437-620-4 SP - 522 EP - 533 PB - NAFEMS CY - Glasgow ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Traglastanalyse - ein strukturmechanisches Verfahren zur Beurteilung von gerissenen Bauteilen und Verbindungen JF - Festigkeits- und Bruchverhalten von Fügeverbindungen : 32. Tagung des DVM-Arbeitskreises Bruchvorgänge ; 22. und 23. Februar 2000 in Berlin / Richard, H. A. [Hrsg] Y1 - 2000 N1 - DVM-Bericht 232 SP - 183 EP - 192 PB - Deutscher Verband für Materialforschung und -prüfung CY - Berlin ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Reliability Analysis of Elasto-Plastic Structures under Variable Loads JF - Inelastic analysis of structures under variable loads : theory and engineering applications / Maier, G.; Weichert, D. [ed] Y1 - 2000 SN - 0-7923-6645-X SP - 269 EP - 288 PB - Kluwer Academic Publ. CY - Dordrecht ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Direct FEM approach to design-by-analysis of pressurized components JF - Achema 2000 : Sonderausgabe / Linde. [Hrsg.: Linde AG. Red.: Volker R. Leski] Y1 - 2000 SP - 79 EP - 81 PB - Linde AG CY - Wiesbaden ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Structural Reliability Analysis of Elasto-Plastic Structures JF - Safety and reliability : proceedings of ESREL '99, the Tenth European Conference on Safety and Reliability, Munich-Garching, Germany, 13 - 17 September 1999 / Schuëller, G. I.; Kafka, P. [eds] Y1 - 1999 SN - 90-5809-109-0 SP - 513 EP - 518 PB - Balkema CY - Rotterdam ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Limit and Shakedown Analysis with Uncertain Data JF - Stochastic optimization techniques : numerical methods and technical applications / Marti, K. [ed] Y1 - 2002 SN - 3-540-42889-5 SP - 241 EP - 254 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Probabilistic limit and shakedown problems JF - Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M. Y1 - 2003 SN - 3-00-010001-6 SP - 217 EP - 268 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - FEM-computation of load carrying capacity of highly loaded passive components by direct methods. Heitzer, M. ; Staat, M. JF - Nuclear Engineering and Design. 193 (1999), H. 3 Y1 - 1999 SN - 0029-5493 SP - 349 EP - 358 ER - TY - JOUR A1 - Staat, Manfred A1 - Fiorini, G. L. A1 - Lensa, W. von A1 - Burgazzi, L. T1 - Reliability Methods for Passive Safety Functions JF - Proceedings of the SMiRT 14 Post Conference Seminar No 18 on Passive Safety Features in Nuclear Installations Y1 - 1997 CY - Pisa ER - TY - JOUR A1 - Staat, Manfred A1 - Baroud, G. A1 - Topcu, M. A1 - Sponagel, Stefan T1 - Soft Materials in Technology and Biology – Characteristics, Properties, and Parameter Identification JF - Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.) Y1 - 2008 SN - 978-3-540-75408-4 SP - 253 EP - 315 PB - Springer CY - Berlin ER - TY - JOUR A1 - Staat, Manfred A1 - Ballmann, J. T1 - Computation of impacts on elastic solids by methods of bicharacteristics JF - Computational Mechanics '88 : theory and applications ; proceedings of the International Conference on Computational Engineering Science April 10-14, 1988, Atlanta, GA, USA ; vol. 2 N2 - Shock waves, explosions, impacts or cavitation bubble collapses may generate stress waves in solids causing cracks or unexpected dammage due to focussing, physical nonlinearity or interaction with existing cracks. There is a growing interest in wave propagation, which poses many novel problems to experimentalists and theorists. KW - Bicharakteristikenverfahren KW - Elastizität KW - elastic solids KW - bicharacteristics Y1 - 1988 SP - 1719 EP - 1722 ER - TY - JOUR A1 - Staat, Manfred A1 - Ballmann, J. T1 - Zur Problematik tensorieller Verallgemeinerungen einachsiger nichtlinearer Materialgesetze JF - Zeitschrift für angewandte Mathematik und Mechanik : ZAMM. 69 (1989), H. 2 Y1 - 1989 SN - 0946-8463 U6 - http://dx.doi.org/10.1515/9783112553169-006 SP - 73 EP - 81 ER - TY - JOUR A1 - Staat, Manfred A1 - Ballmann, J. T1 - Wave Propagation and Focussing in Plates JF - Impact loading and dynamic behaviour of materials : Papers presented at the International Conference on Impact Loading and Dynamic Behaviour of Materials, Vol. 2 / Chiem, C. Y.; Kunze, L. (u.a.) [eds] Y1 - 1988 PB - DGM Informationsges. CY - Oberursel ER - TY - JOUR A1 - Staat, Manfred A1 - Ballmann, J. T1 - Anisotrope Ausbreitung und Fokussierung von Beschleunigungswellen in vorgespannten nichtlinearelastischen Scheiben JF - Wellenfokussierung, Kolloquium des SFB 27, RWTH Aachen Y1 - 1985 SP - 140 EP - 158 CY - Aachen ER - TY - JOUR A1 - Staat, Manfred T1 - Problems and Chances for Probabilistic Fracture Mechanics in the Analysis of Steel Pressure Boundary Reliability JF - Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994 Y1 - 1996 N1 - IAEA-TECDOC-920 ; Onlinezugriff erfolgt auf die überarb. Ausg. 2006 SP - 43 EP - 55 CY - Vienna ER - TY - JOUR A1 - Staat, Manfred T1 - Sensitivity of and Influences on the Reliability of an HTR-Module Primary Circuit Pressure Boundary JF - Transactions of the 12th International Conference on Structural Mechanics in Reactor Technology (SMiRT-12) / Kussmaul, K. [ed] Y1 - 1993 SN - 0-444-81515-5 N1 - Vol. M, Paper MG10/2 SP - 147 EP - 152 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Staat, Manfred T1 - Reliability of the Primary Circuit Pressure Boundary of an HTR-Module under Accident Conditions JF - Safety and reliability assessment : an integral approach ; ESREL'93 ; proceedings of the European Safety and Reliability Conference, Munich, Germany, May 10th - 12th 1993 / Kafka, P. [ed] Y1 - 1993 SN - 0-444-81561-9 SP - 331 EP - 342 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Staat, Manfred T1 - Probabilistische Bewertung des bruchmechanischen Verhaltens der Primärkreisdruckumschließung eines HTR-Moduls Y1 - 1992 N1 - 18. MPA-Seminar : Sicherheit und Verfügbarkeit in der Anlagentechnik mit dem Schwerpunkt Kernenergie. Stuttgart (1992), 27.1-27.18 ER - TY - JOUR A1 - Staat, Manfred T1 - Versagenswahrscheinlichkeit der Primärkreisdruckumschließung eines HTR-Moduls zur Prozeßwärmegewinnung unter Störfallbedingungen bei verschiedenen Versagensmoden Y1 - 1991 N1 - 17. MPA-Seminar : Sicherheit und Verfügbarkeit in der Anlagentechnik mit dem Schwerpunkt Kerntechnik, Stuttgart (1991), 22.1-22.20 ER - TY - JOUR A1 - Staat, Manfred T1 - Some Achievements of the European Project LISA for FEM Based Limit and Shakedown Analysis JF - Computational mechanics : developments and applications, 2002 : presented at the 2002 ASME Pressure Vessels and Piping Conference, Vancouver, British Columbia, Canada, August 5 - 9. / Badie, N. [ed] Y1 - 2002 SN - 0791846520 N1 - Serie PVP ; vol. 441. SP - 177 EP - 185 PB - American Society of Mechanical Engineers CY - New York ER - TY - JOUR A1 - Staat, Manfred T1 - Versagenswahrscheinlichkeit der Primärkreisdruckumschließung eines HTR-Moduls zur Prozeßwärmegewinnung unter Störfallbedingungen JF - Jahrestagung Kerntechnik '91 / Kerntechnische Gesellschaft e.V. ; Deutsches Atomforum e.V Y1 - 1991 SP - 123 EP - 126 PB - INFORUM CY - Bonn ER - TY - JOUR A1 - Staat, Manfred T1 - Anisotrope Wellenausbreitung in isotropen hyperelastischen Scheiben JF - Zeitschrift für angewandte Mathematik und Mechanik : ZAMM. 67 (1987), H. 4 Y1 - 1987 SN - 0946-8463 SP - T241 EP - T243 ER - TY - JOUR A1 - Staat, Manfred T1 - Plastic collapse analysis of longitudinally flawed pipes and vessels JF - Nuclear Engineering and Design. 234 (2004), H. 1-3 Y1 - 2004 SN - 0029-5493 SP - 25 EP - 43 ER - TY - JOUR A1 - Staat, Manfred T1 - Local and global collapse pressure of longitudinally flawed pipes and cylindrical vessels JF - International Journal of Pressure Vessels and Piping. 82 (2005), H. 3 Y1 - 2005 SN - 0308-0161 SP - 217 EP - 225 ER - TY - JOUR A1 - Staat, Manfred T1 - Failure probabilities of the primary circuit pressure boundary of an HTR-Module for process heat generation under accident conditions for different failure modes JF - Nuclear Engineering and Design. 144 (1993), H. 1 Y1 - 1993 SN - 0029-5493 SP - 53 EP - 67 ER - TY - JOUR A1 - Staat, Manfred T1 - Reliability of an HTR-module primary circuit pressure boundary Influences, sensitivity, and comparison with a PWR JF - Nuclear Engineering and Design. 158 (1995), H. 2-3 Y1 - 1995 SN - 0029-5493 SP - 333 EP - 340 ER - TY - JOUR A1 - Staat, Manfred T1 - Probabilistic assessment of the fracture mechanics behaviour of an HTR-module primary circuit pressure boundary JF - Nuclear Engineering and Design. 160 (1996), H. 1-2 Y1 - 1996 SN - 0029-5493 SP - 221 EP - 236 ER - TY - JOUR A1 - Staat, Manfred T1 - Limit and shakedown analysis under uncertainty JF - International journal of computational methods : IJCM Y1 - 2013 SN - 0219-8762 SP - Publ. online PB - World Scientific Publishing CY - Singapore ER - TY - JOUR A1 - Staat, Manfred T1 - Plastic collapse analysis of longitudinally flawed pipes and vessels N2 - Improved collapse loads of thick-walled, crack containing pipes and vessels are suggested. Very deep cracks have a residual strength which is better modelled by a global limit load. In all burst tests, the ductility of pressure vessel steels was sufficiently high whereby the burst pressure could be predicted by limit analysis with no need to apply fracture mechanics. The relative prognosis error increases however, for long and deep defects due to uncertainties of geometry and strength data. KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohr KW - Rohrbruch KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohrbruch KW - Fehlerstellen KW - pipes KW - vessels KW - load limit KW - burst tests KW - burst pressure KW - flaw Y1 - 2004 ER - TY - JOUR A1 - Staat, Manfred T1 - Cyclic plastic deformation tests to verify FEM-based shakedown analyses N2 - Fatigue analyses are conducted with the aim of verifying that thermal ratcheting is limited. To this end it is important to make a clear distintion between the shakedown range and the ratcheting range (continuing deformation). As part of an EU-supported research project, experiments were carried out using a 4-bar model. The experiment comprised a water-cooled internal tube, and three insulated heatable outer test bars. The system was subjected to alternating axial forces, superimposed with alternating temperatures at the outer bars. The test parameters were partly selected on the basis of previous shakedown analyses. During the test, temperatures and strains were measured as a function of time. The loads and the resulting stresses were confirmed on an ongoing basis during performance of the test, and after it. Different material models were applied for this incremental elasto-plastic analysis using the ANSYS program. The results of the simulation are used to verify the FEM-based shakedown analysis. KW - Materialermüdung KW - Einspielen KW - Materialermüdung KW - shakedown analyses KW - thermal ratcheting KW - fatigue analyses Y1 - 2001 ER - TY - JOUR A1 - Staat, Manfred T1 - Local and global collapse pressure of longitudinally flawed pipes and cylindrical vessels N2 - Limit loads can be calculated with the finite element method (FEM) for any component, defect geometry, and loading. FEM suggests that published long crack limit formulae for axial defects under-estimate the burst pressure for internal surface defects in thick pipes while limit loads are not conservative for deep cracks and for pressure loaded crack-faces. Very deep cracks have a residual strength, which is modelled by a global collapse load. These observations are combined to derive new analytical local and global collapse loads. The global collapse loads are close to FEM limit analyses for all crack dimensions. KW - Finite-Elemente-Methode KW - Grenzwertberechnung KW - Axialbelastung KW - FEM KW - Grenzwertberechnung KW - Axialbelastung KW - Traglastanalyse KW - Limit analysis KW - Global and local collapse KW - Axially cracked pipe KW - Pressure loaded crack-face Y1 - 2005 ER - TY - JOUR A1 - Staat, Manfred T1 - Direct finite element route for design-by-analysis of pressure components N2 - In the new European standard for unfired pressure vessels, EN 13445-3, there are two approaches for carrying out a Design-by-Analysis that cover both the stress categorization method (Annex C) and the direct route method (Annex B) for a check against global plastic deformation and against progressive plastic deformation. This paper presents the direct route in the language of limit and shakedown analysis. This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for mechanical and thermal actions. One observation from the examples is that the so-called 3f (3Sm) criterion fails to be a reliable check against progressive plastic deformation. Precise conditions are given, which greatly restrict the applicability of the 3f criterion. KW - Einspielen KW - Plastizität KW - Deformation KW - Analytischer Zulaessigkeitsnachweis KW - Einspiel-Analyse KW - fortschreitende plastische Deformation KW - alternierend Verformbarkeit KW - Einspiel-Kriterium KW - Design-by-analysis KW - Shakedown analysis KW - Progressive plastic deformation KW - Alternating plasticity KW - Shakedown criterion Y1 - 2005 ER - TY - JOUR A1 - Staat, Manfred T1 - Shakedown and ratchetting under tension-torsion loadings: analysis and experiments N2 - Structural design analyses are conducted with the aim of verifying the exclusion of ratchetting. To this end it is important to make a clear distinction between the shakedown range and the ratchetting range. The performed experiment comprised a hollow tension specimen which was subjected to alternating axial forces, superimposed with constant moments. First, a series of uniaxial tests has been carried out in order to calibrate a bounded kinematic hardening rule. The load parameters have been selected on the basis of previous shakedown analyses with the PERMAS code using a kinematic hardening material model. It is shown that this shakedown analysis gives reasonable agreement between the experimental and the numerical results. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis. KW - Einspielen KW - Einspielen KW - Ratchetting KW - Zug-Druck Belastung KW - shakedown KW - ratchetting KW - tension–torsion loading Y1 - 2003 ER - TY - JOUR A1 - Staat, Manfred T1 - Basis Reduction for the Shakedown Problem for Bounded Kinematic Hardening Material N2 - Limit and shakedown analysis are effective methods for assessing the load carrying capacity of a given structure. The elasto–plastic behavior of the structure subjected to loads varying in a given load domain is characterized by the shakedown load factor, defined as the maximum factor which satisfies the sufficient conditions stated in the corresponding static shakedown theorem. The finite element dicretization of the problem may lead to very large convex optimization. For the effective solution a basis reduction method has been developed that makes use of the special problem structure for perfectly plastic material. The paper proposes a modified basis reduction method for direct application to the two-surface plasticity model of bounded kinematic hardening material. The considered numerical examples show an enlargement of the load carrying capacity due to bounded hardening. KW - Finite-Elemente-Methode KW - Einspielen KW - Basis Reduktion KW - konvexe Optimierung KW - FEM KW - Druckgeräte KW - Basis reduction KW - Convex optimization KW - FEM KW - Shakedown analysis Y1 - 2000 ER - TY - JOUR A1 - Staat, Manfred T1 - LISA - a European project for FEM-based limit and shakedown analysis N2 - The load-carrying capacity or the safety against plastic limit states are the central questions in the design of structures and passive components in the apparatus engineering. A precise answer is most simply given by limit and shakedown analysis. These methods can be based on static and kinematic theorems for lower and upper bound analysis. Both may be formulated as optimization problems for finite element discretizations of structures. The problems of large-scale analysis and the extension towards realistic material modelling will be solved in a European research project. Limit and shakedown analyses are briefly demonstrated with illustrative examples. KW - Einspielen KW - Traglast KW - Finite-Elemente-Methode KW - Traglastanalyse KW - Einspielanalyse KW - FEM KW - limit analysis KW - shakedown analysis Y1 - 2001 ER - TY - JOUR A1 - Staat, Manfred T1 - Direct FEM Limit and Shakedown Analysis with Uncertain Data N2 - The structural reliability with respect to plastic collapse or to inadaptation is formulated on the basis of the lower bound limit and shakedown theorems. A direct definition of the limit state function is achieved which permits the use of the highly effective first order reliability methods (FORM) is achieved. The theorems are implemented into a general purpose FEM program in a way capable of large-scale analysis. The limit state function and its gradient are obtained from a mathematical optimization problem. This direct approach reduces considerably the necessary knowledge of uncertain technological input data, the computing time, and the numerical error, leading to highly effective and precise reliability analyses. KW - Finite-Elemente-Methode KW - Einspielen KW - FEM KW - Einspielanalyse KW - shakedown KW - limit load KW - reliability analysis KW - FEM KW - direct method Y1 - 2000 ER - TY - JOUR A1 - Staat, Manfred T1 - Limit and shakedown analysis under uncertainty JF - Tap chi Khoa hoc & ung dung - Dai hoc Ton Duc Thang Y1 - 2012 N1 - = Journal of Applied Sciences - Ton Duc Thang University VL - 19 SP - 45 EP - 47 ER - TY - JOUR A1 - Schieren, Mark A1 - Kleinschmidt, Joris A1 - Schmutz, Axel A1 - Loop, Torsten A1 - Gatzweiler, Karl-Heinz A1 - Staat, Manfred A1 - Wappler, Frank A1 - Defosse, Jerome T1 - Comparison of forces acting on maxillary incisors during tracheal intubation with different laryngoscopy techniques: a blinded manikin study JF - Anaesthesia Y1 - 2019 SN - 1365-2044 U6 - http://dx.doi.org/10.1111/anae.14815 N1 - Die Anhänge "Table S1 (Impact of sex and level of training on dental force. Results presented as median (IQR [range]) and n (%))" und "Appendix S1 (Measurement technique.)" stehen unter "Supporting Information" zum Download bereit. VL - 74 IS - 12 PB - Wiley-Blackwell CY - Oxford ER - TY - JOUR A1 - Rausch, Valentin A1 - Kahmann, Stephanie Lucina A1 - Baltschun, Christoph A1 - Staat, Manfred A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - Pressure distribution to the distal biceps tendon at the radial tuberosity: a biomechanical study JF - The Journal of Hand Surgery N2 - Purpose Mechanical impingement at the narrow radioulnar space of the tuberosity is believed to be an etiological factor in the injury of the distal biceps tendon. The aim of the study was to compare the pressure distribution at the proximal radioulnar space between 2 fixation techniques and the intact state. Methods Six right arms and 6 left arms from 5 female and 6 male frozen specimens were used for this study. A pressure transducer was introduced at the height of the radial tuberosity with the intact distal biceps tendon and after 2 fixation methods: the suture-anchor and the cortical button technique. The force (N), maximum pressure (kPa) applied to the radial tuberosity, and the contact area (mm²) of the radial tuberosity with the ulna were measured and differences from the intact tendon were detected from 60° supination to 60° pronation in 15° increments with the elbow in full extension and in 45° and 90° flexion of the elbow. Results With the distal biceps tendon intact, the pressures during pronation were similar regardless of extension and flexion and were the highest at 60° pronation with 90° elbow flexion (23.3 ± 53.5 kPa). After repair of the tendon, the mean peak pressure, contact area, and total force showed an increase regardless of the fixation technique. Highest peak pressures were found using the cortical button technique at 45° flexion of the elbow and 60° pronation. These differences were significantly different from the intact tendon. The contact area was significantly larger in full extension and 15°, 30°, and 60° pronation using the cortical button technique. Conclusions Pressures on the distal biceps tendon at the radial tuberosity increase during pronation, especially after repair of the tendon. Clinical relevance Mechanical impingement could play a role in both the etiology of primary distal biceps tendon ruptures and the complications occurring after fixation of the tendon using certain techniques. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.jhsa.2020.01.006 SN - 0363-5023 VL - 45 IS - 8 SP - 776.e1 EP - 776.e9 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Rausch, Valentin A1 - Harbrecht, Andreas A1 - Kahmann, Stephanie Lucina A1 - Fenten, Thomas A1 - Jovanovic, Nebojsa A1 - Hackl, Michael A1 - Müller, Lars P. A1 - Staat, Manfred A1 - Wegmann, Kilian T1 - Osteosynthesis of Phalangeal Fractures: Biomechanical Comparison of Kirschner Wires, Plates, and Compression Screws JF - The Journal of Hand Surgery N2 - Purpose The aim of this study was to compare several osteosynthesis techniques (intramedullary headless compression screws, T-plates, and Kirschner wires) for distal epiphyseal fractures of proximal phalanges in a human cadaveric model. Methods A total of 90 proximal phalanges from 30 specimens (index, ring, and middle fingers) were used for this study. After stripping off all soft tissue, a transverse distal epiphyseal fracture was simulated at the proximal phalanx. The 30 specimens were randomly assigned to 1 fixation technique (30 per technique), either a 3.0-mm intramedullary headless compression screw, locking plate fixation with a 2.0-mm T-plate, or 2 oblique 1.0-mm Kirschner wires. Displacement analysis (bending, distraction, and torsion) was performed using optical tracking of an applied random speckle pattern after osteosynthesis. Biomechanical testing was performed with increasing cyclic loading and with cyclic load to failure using a biaxial torsion-tension testing machine. Results Cannulated intramedullary compression screws showed significantly less displacement at the fracture site in torsional testing. Furthermore, screws were significantly more stable in bending testing. Kirschner wires were significantly less stable than plating or screw fixation in any cyclic load to failure test setup. Conclusions Intramedullary compression screws are a highly stable alternative in the treatment of transverse distal epiphyseal phalangeal fractures. Kirschner wires seem to be inferior regarding displacement properties and primary stability. Clinical relevance Fracture fixation of phalangeal fractures using plate osteosynthesis may have the advantage of a very rigid reduction, but disadvantages such as stiffness owing to the more invasive surgical approach and soft tissue irritation should be taken into account. Headless compression screws represent a minimally invasive choice for fixation with good biomechanical properties. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.jhsa.2020.04.010 SN - 0363-5023 VL - 45 IS - 10 SP - 987.e1 EP - 987.e8 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Vu, Khoi Duc A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - A primal-dual algorithm for shakedown analysis of elastic-plastic bounded linearly kinematic hardening bodies Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 7 ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - An Upper Bound Algorithm for Limit and Shakedown Analysis of Bounded Linearly Kinematic Hardening Structures JF - Limit State of Materials and Structures : Direct Methods 2. Saxcé, Géry de (Hrsg.) Y1 - 2013 SN - 978-94-007-5424-9 SP - 71 EP - 87 PB - Springer CY - Dordrecht ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - FEM-based shakedown analysis of hardening structures JF - Asia Pacific journal on computational engineering N2 - This paper develops a new finite element method (FEM)-based upper bound algorithm for limit and shakedown analysis of hardening structures by a direct plasticity method. The hardening model is a simple two-surface model of plasticity with a fixed bounding surface. The initial yield surface can translate inside the bounding surface, and it is bounded by one of the two equivalent conditions: (1) it always stays inside the bounding surface or (2) its centre cannot move outside the back-stress surface. The algorithm gives an effective tool to analyze the problems with a very high number of degree of freedom. Our numerical results are very close to the analytical solutions and numerical solutions in literature. Y1 - 2014 U6 - http://dx.doi.org/10.1186/2196-1166-1-4 SN - 2196-1166 (E-Journal) IS - 1 SP - Article No. 4 PB - SpringerOpen CY - Berlin ER - TY - JOUR A1 - Novacek, V. A1 - Tran, Thanh Ngoc A1 - Klinge, U. A1 - Tolba, R. H. A1 - Staat, Manfred A1 - Bronson, D. G. A1 - Miesse, A. M. A1 - Whiffen, J. A1 - Turquier, F. T1 - Finite element modelling of stapled colorectal end-to-end anastomosis : Advantages of variable height stapler design JF - Journal of Biomechanics N2 - The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge. KW - Variable height stapler design KW - Anastomotic leakage KW - Finite element modelling KW - End-to-end colorectal anastomosis KW - Surgical staplers Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jbiomech.2012.07.021 SN - 1873-2380 VL - 45 IS - 115 SP - 2693 EP - 2697 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Nguyen, Nhu Huynh A1 - Duong, Minh Tuan A1 - Tran, Thanh Ngoc A1 - Pham, Phu Tinh A1 - Grottke, O. A1 - Tolba, R. A1 - Staat, Manfred T1 - Influence of a freeze–thaw cycle on the stress–stretch curves of tissues of porcine abdominal organs JF - Journal of Biomechanics N2 - The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze–thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze–thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines. KW - Autolysis KW - Decomposition KW - Freeze–thaw process KW - Spleen KW - Liver Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jbiomech.2012.07.008 SN - 1873-2380 VL - 45 IS - 14 SP - 2382 EP - 2386 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Nguyen, N.-H. A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred T1 - A hyperelastic model of biological tissue materials in tubular organs Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 12 ER - TY - JOUR A1 - Michael, Hackl A1 - Mayer, Katharina A1 - Weber, Mareike A1 - Staat, Manfred A1 - van Riet, Roger A1 - Burkhart, Klau Josef A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - Plate osteosynthesis of proximal ulna fractures : a biomechanical micromotion analysis JF - The journal of hand surgery Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.jhsa.2017.05.014 SN - 0363-5023 VL - 42 IS - 10 SP - 834.e1 EP - 834.e7 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Meyer, Carolin A1 - Gaalen, Kerstin van A1 - Leschinger, Tim A1 - Scheyerer, Max J. A1 - Neiss, Wolfram F. A1 - Staat, Manfred A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement JF - BioMed Research International Y1 - 2019 U6 - http://dx.doi.org/10.1155/2019/9232813 SP - Article ID 9232813 ER - TY - JOUR A1 - Linder, Peter A1 - Beckler, Matthias A1 - Doerr, Leo A1 - Stoelzle-Feix, Sonja A1 - Fertig, Niels A1 - Jung, Alexander A1 - Staat, Manfred A1 - Gossmann, Matthias T1 - A new in vitro tool to investigate cardiac contractility under physiological mechanical conditions JF - Journal of Pharmacological and Toxicological Methods Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.vascn.2019.05.162 SN - 1056-8719 VL - 99 IS - Article number 106595 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Linden, A. A1 - Fischöder, M. A1 - Laack, Walter van A1 - Staat, Manfred T1 - Einschränkung von Taluskippung und -vorschub durch Sprunggelenkorthesen nach fibularer Bandruptur JF - OUP Zeitschrift für die orthopädische und unfallchirurgische Praxis N2 - Die fibulare Bandruptur zählt zu einer der am häufigsten auftretenden Verletzungen des Bewegungsapparats. In den meisten Fällen wird heute die konservativ frühfunktionelle Therapie mit Sprunggelenkorthesen allgemein bevorzugt. Im Rahmen der vorliegenden Studie wurden 14 verschiedene Sprunggelenkorthesen im Hinblick auf ihre Einschränkung von Taluskippung und Talusvorschub untersucht. Zur Simulation einer fibularen Bandruptur wurde ein Unterschenkelmodell aus Holz mit Fußteil, mit angelegten Orthesen in einen Scheuba-Halteapparat eingespannt und mit 150 N seitlich sowie anterior-posterior belastet. Anhand der erstellten "gehaltenen" Röntgenaufnahmen konnten Taluskippung und Talusvorschub jeder einzelnen Orthese eindeutig bestimmt werden. Die meisten Orthesen erreichten zufriedenstellende Ergebnisse. Es stellte sich heraus, dass vor allem eine eng anliegende, im Gelenkbereich anatomisch angepasste Form vorteilhaft zu sein scheint. N2 - The ankle sprain is actually one of the most common injuries. Nowadays the conservative pre-functional therapy with ankle braces is generally preferred. In the present study 14 different ankle braces were tested with regard to their ability to constrict the talar tilt and anterior drawer displacement. As part of the tests a wooden model of a foot was used in order to simulate an ankle sprain. This model was clamped in a Scheuba-device with different ankle braces and a force of 150 N was applied to it. The stress radiographs showed different talar tilts and anterior drawers of each brace. Most ankle braces achieved a satisfying result. It has become obvious that a tight fitting and an anatomically designed shape seem to be favourable. T2 - Constraint of talar tilt and anterior drawer by different ankle braces after the rupture of fibular ligaments KW - Sprunggelenkorthesen KW - fibulare Bandruptur KW - Distorsion des oberen Sprunggelenks KW - ankle sprain KW - rupture of the fibular ligament KW - ankle braces Y1 - 2013 SN - 2193-5785 U6 - http://dx.doi.org/10.3238/oup.2013.0306-0309 VL - 2 IS - 6 SP - 306 EP - 309 PB - Deutscher Ärzte-Verl. CY - Köln ER - TY - JOUR A1 - Levers, A. A1 - Staat, Manfred A1 - Laack, Walter van T1 - Analyse der Langzeitwirkung der MBST® KernspinResonanzTherapie bei Gonarthrose T1 - Analysis of the Long-term Effect of the MBST® Nuclear Magnetic Resonance Therapy on Gonarthrosis N2 - Originalausgabe: Orthopädische Praxis Jg. 47. 2011 H. 11; S. 536-543. Mit freundlicher Genehmigung des Verlags Zusammenfassung: Auf der Basis von Patientenabfragen mittels Fragebogen zum Schmerzempfinden und zur Einschränkung bei Aktivitäten des alltäglichen Lebens wird die Langzeitwirkung der MBST® KernspinResonanz-Therapie bei Gonarthrose untersucht. An der Studie nahmen 39 Patienten teil, bei denen die Therapie bis zu vier Jahre zurückliegt. Neben einer Gesamtbetrachtung wird der Erfolg auch in Abhängigkeit von Alter, Geschlecht und sportlicher Aktivität analysiert. Insgesamt weist die Studie auf eine anhaltende Verbesserung des Gesundheitszustands mit zum Teil deutlicher Schmerzlinderung auch noch nach vier Jahren hin, jedoch mit einer leichten Schmerzzunahme gegen Ende des Untersuchungszeitraums von vier Jahren. Eine tendenziell positivere Wirkung bei Frauen, älteren Menschen oder auch sportlich nicht-aktiven Patienten lässt auf eine mögliche Beeinflussung des Erfolgs der Therapie durch (Über-)Belastung im Alltag schließen. Ein zusätzlich positiver Effekt der Therapie auf die Knochendichte ist ebenfalls denkbar, dies bleibt jedoch offen. N2 - Original edition: Orthopädische Praxis Vol. 47. 2011 Issue 11; P. 536-543. On the friendly authority of the publisher. Abstract: Based upon a questionnaire for patient-queries regarding pain-sensation and activity-restrictions during everyday task, the long-term effect of MBST® nuclear magnetic resonance therapy is studied in osteoarthritis of the knee. 39 patients, whose therapy dates back up to four years, participated in the study. In addition to an overall view, the success of this therapy is also analyzed regarding age, gender and physical activities. Overall, the study pointed out a sustained improvement in the patients´ local health-status with a significant pain-relief even after four years, but also with a slight increase in pain towards the end of that four-year period. There tends to be more positive effect on women, on elderly of also on even non-sports-active patients which suggest a possible influence by daily (over)-stressing on the success of the therapy. An additional positive effect of the therapy on bone density is also conceivable, however, this remains open. KW - Kniegelenkarthrose KW - Gonarthrose KW - MBST KW - Arthosetherapie KW - gonarthrosis KW - MBST KW - arthrosis therapy Y1 - 2011 ER - TY - JOUR A1 - Levers, A. A1 - Staat, Manfred A1 - Laack, Walter van T1 - Analysis of the long-term effect of the MBST® nuclear magnetic resonance therapy on gonarthrosis JF - Orthopedic Practice Y1 - 2016 VL - 47 IS - 11 SP - 521 EP - 528 ER - TY - JOUR A1 - Leschinger, Tim A1 - Birgel, Stefan A1 - Hackl, Michael A1 - Staat, Manfred A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - A musculoskeletal shoulder simulation of moment arms and joint reaction forces after medialization of the supraspinatus footprint in rotator cuff repair JF - Computer Methods in Biomechanics and Biomedical Engineering Y1 - 2019 U6 - http://dx.doi.org/10.1080/10255842.2019.1572749 IS - Early view PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Leschinger, Tim A1 - Besch, Katharina A1 - Aydin, Cansu A1 - Staat, Manfred A1 - Scaal, Martin A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - Irreparable rotator cuff tears: a biomechanical comparison of superior capsuloligamentous complex reconstruction techniques and an interposition graft technique JF - The Orthopaedic Journal of Sports Medicine Y1 - 2019 U6 - http://dx.doi.org/10.1177/2325967119864590 VL - 7 IS - 8 SP - 1 EP - 5 ER - TY - JOUR A1 - Kühn, Raoul-Roman A1 - Haugner, Werner A1 - Staat, Manfred A1 - Sponagel, Stefan T1 - A Two Phase Mixture Model based on Bone Observation N2 - An optimization method is developed to describe the mechanical behaviour of the human cancellous bone. The method is based on a mixture theory. A careful observation of the behaviour of the bone material leads to the hypothesis that the bone density is controlled by the principal stress trajectories (Wolff’s law). The basic idea of the developed method is the coupling of a scalar value via an eigenvalue problem to the principal stress trajectories. On the one hand this theory will permit a prediction of the reaction of the biological bone structure after the implantation of a prosthesis, on the other hand it may be useful in engineering optimization problems. An analytical example shows its efficiency. KW - Knochen KW - Knochenbildung KW - Knochenchirugie KW - Strukturanalyse KW - Schwammknochen KW - Knochendichte KW - Wolffsches Gesetz KW - bone structure KW - bone density KW - Wolff's Law KW - cancellous bone Y1 - 2004 ER - TY - JOUR A1 - Kohler, Annette A1 - Kirschner-Hermanns, Ruth A1 - Staat, Manfred A1 - Brehmer, Bernhard T1 - Pathogenese, funktionelle und anatomische Aspekte der weiblichen Belastungsinkontinenz T1 - Female stress incontinence: aspects of pathogenesis and functional anatomy JF - Aktuelle Urologie N2 - Der vorliegende Artikel fokussiert sich auf die weibliche Belastungsinkontinenz als Insuffizienz der Speicherfunktion der Blase, auch wenn im klinischen Alltag die Harninkontinenz der Frau häufig verschiedene Ursachen hat und insbesondere eine Belastungsinkontinenz im Alter und bei neurologischer Komorbidität nur selten isoliert vorkommt. Das kleine Becken der Frau ist sowohl als Funktions- als auch als strukturelle Einheit zu betrachten. Dabei unterliegen bei der Frau Blase, Harnröhre, Gebärmutter und Enddarm sowie die muskulären und ligamentösen Strukturen des kleinen Beckens durch Fertilitätsphase, mögliche Schwangerschaften, Geburten und Menopausen-Phase, über das „normale Altern“ hinaus, gravierenden Veränderungen. This article focuses on female stress incontinence in the form of pelvic floor dysfunction and urethral sphincter deficiency, although isolated stress incontinence accounts for less than half of all incontinence cases. Especially in women of old age and those with neurological comorbidities, the causes of incontinence are mostly multifactorial. Also it has to be considered that the female bladder, urethra, uterus and rectum as well as the muscular and ligamentous structures of the female pelvis minor are affected by phases of fertility, possible pregnancies, births and menopause in addition to the normal ageing process. Y1 - 2018 U6 - http://dx.doi.org/10.1055/s-0043-120616 SN - 1438-8820 VL - 49 IS - 1 SP - 47 EP - 51 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Knox, Ronald A1 - Bruggemann, Andrea A1 - Gossmann, Matthias A1 - Thomas, Ulrich A1 - Horváth, András A1 - Dragicevic, Elena A1 - Stoelzle-Feix, Sonja A1 - Fertig, Niels A1 - Jung, Alexander A1 - Raman, Aravind Hariharan A1 - Staat, Manfred A1 - Linder, Peter T1 - Combining physiological relevance and throughput for in vitro cardiac contractility measurement JF - Biophysical Journal N2 - Despite increasing acceptance of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) in safety pharmacology, controversy remains about the physiological relevance of existing in vitro models for their mechanical testing. We hypothesize that existing signs of immaturity of the cell models result from an improper mechanical environment. We cultured hiPSC-CMs in a 96-well format on hyperelastic silicone membranes imitating their native mechanical environment, resulting in physiological responses to compound stimuli.We validated cell responses on the FLEXcyte 96, with a set of reference compounds covering a broad range of cellular targets, including ion channel modulators, adrenergic receptor modulators and kinase inhibitors. Acute (10 - 30 min) and chronic (up to 7 days) effects were investigated. Furthermore, the measurements were complemented with electromechanical models based on electrophysiological recordings of the used cell types.hiPSC-CMs were cultured on freely-swinging, ultra-thin and hyperelastic silicone membranes. The weight of the cell culture medium deflects the membranes downwards. Rhythmic contraction of the hiPSC-CMs resulted in dynamic deflection changes which were quantified by capacitive distance sensing. The cells were cultured for 7 days prior to compound addition. Acute measurements were conducted 10-30 minutes after compound addition in standard culture medium. For chronic treatment, compound-containing medium was replaced daily for up to 7 days. Electrophysiological properties of the employed cell types were recorded by automated patch-clamp (Patchliner) and the results were integrated into the electromechanical model of the system.Calcium channel agonist S Bay K8644 and beta-adrenergic stimulator isoproterenol induced significant positive inotropic responses without additional external stimulation. Kinase inhibitors displayed cardiotoxic effects on a functional level at low concentrations. The system-integrated analysis detected alterations in beating shape as well as frequency and arrhythmic events and we provide a quantitative measure of these. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.bpj.2019.11.3104 SN - 0006-3495 N1 - Raman, Arayind Hariharan im Artikel unter dem Namen: Raman, Alexander H. VL - 118 IS - Issue 3, Supplement 1 SP - 570a PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Keutmann, Sabine A1 - Staat, Manfred A1 - Laack, Walter van T1 - Untersuchung der thermischen Auswirkung von therapeutischem Ultraschall N2 - Zusammenfassung: In der Orthopädie zählt der therapeutische Ultraschall als Mittel zur Prävention und Therapiebegleitung. Er hat mechanische, thermische und physiko-chemische Auswirkungen auf den menschlichen Körper. Um mehr Erkenntnisse über die thermischen Auswirkungen zu erlangen, wurden Versuche an einem Hydrogel-Phantom und an Probanden durchgeführt. Dabei entstand eine signifikante Erwärmung des Gewebes, welche beim Probandenversuch an der Oberfläche und beim Hydrogelversuch in der Tiefe gemessen wurde. Summary: In orthopaedics, therapeutic ultrasound is a tool of prevention and therapy support. It has mechanical, thermal and physico-chemical effects on the human body. Tests with a hydrogel phantom and with human probands have been performed in order to obtain more knowledge about their thermal effects. Both tests measured temperature increases in cell tissue, on the surface with the human proband test and in depth with the hydrogel phantom test. T2 - Research about the thermal effects of therapeutic ultrasound Y1 - 2018 SN - 2193-5793 SN - 2193-5785 (Druckausgabe) VL - 7 IS - 10 SP - 518 EP - 522 PB - Deutscher Ärzte-Verl. CY - Köln ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Flight style optimization in ski jumping on normal, large, and ski flying hills JF - Journal of biomechanics Y1 - 2013 SN - 1873-2380 (E-Journal); 0021-9290 (Print) N1 - Corrigendum to “Flight style optimization in ski jumping on normal, large, and ski flying hills” [J. Biomech 47 (2014) 716-722] Journal of Biomechanics, 2018;71:313. VL - Vol. 47 IS - Iss. 3 SP - 716 EP - 722 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Corrigendum to “Flight style optimization in ski jumping on normal, large, and ski flying hills” [J. Biomech 47 (2014) 716–722] JF - Journals of Biomechanics Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.jbiomech.2018.02.001 SN - 0021-9290 N1 - refers to Journal of Biomechanics Vol 47, Issue 3, Pages 716-722: https://doi.org/10.1016/j.jbiomech.2013.11.021 SP - 313 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred T1 - Modeling and simulation of human induced pluripotent stem cell-derived cardiac tissue JF - GAMM - Mitteilungen der Gesellschaft für Angewandte Mathematik und Mechanik Y1 - 2019 U6 - http://dx.doi.org/10.1002/gamm.201900002 SN - 1522-2608 VL - 42 IS - 4 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred T1 - Erratum to "Modeling and simulation of human induced pluripotent stem cell-derived cardiac tissue" [GAMM-Mitteilungen, (2019), 42, 4, 10.1002/gamm.201900002] JF - GAMM-Mitteilungen Y1 - 2020 U6 - http://dx.doi.org/10.1002/gamm.202000011 SN - 1522-2608 N1 - Refers to: Modeling and simulation of human induced pluripotent stem cell-derived cardiac tissue. Alexander Jung, Manfred Staat. Volume 42, Issue 4. GAMM-Mitteilungen, 2019. https://doi.org/10.1002/gamm.201900002 VL - 43 IS - 4 PB - Wiley-VCH GmbH CY - Weinheim ER - TY - JOUR A1 - Jung, Alexander A1 - Müller, Wolfram A1 - Staat, Manfred T1 - Wind and fairness in ski jumping: A computer modelling analysis JF - Journal of Biomechanics N2 - Wind is closely associated with the discussion of fairness in ski jumping. To counter-act its influence on the jump length, the International Ski Federation (FIS) has introduced a wind compensation approach. We applied three differently accurate computer models of the flight phase with wind (M1, M2, and M3) to study the jump length effects of various wind scenarios. The previously used model M1 is accurate for wind blowing in direction of the flight path, but inaccuracies are to be expected for wind directions deviating from the tangent to the flight path. M2 considers the change of airflow direction, but it does not consider the associated change in the angle of attack of the skis which additionally modifies drag and lift area time functions. M3 predicts the length effect for all wind directions within the plane of the flight trajectory without any mathematical simplification. Prediction errors of M3 are determined only by the quality of the input data: wind velocity, drag and lift area functions, take-off velocity, and weight. For comparing the three models, drag and lift area functions of an optimized reference jump were used. Results obtained with M2, which is much easier to handle than M3, did not deviate noticeably when compared to predictions of the reference model M3. Therefore, we suggest to use M2 in future applications. A comparison of M2 predictions with the FIS wind compensation system showed substantial discrepancies, for instance: in the first flight phase, tailwind can increase jump length, and headwind can decrease it; this is opposite of what had been anticipated before and is not considered in the current wind compensation system in ski jumping. Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.jbiomech.2018.05.001 SN - 0021-9290 IS - 75 SP - 147 EP - 153 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jung, Alexander A1 - Müller, Wolfram A1 - Staat, Manfred T1 - Optimization of the flight technique in ski jumping: the influence of wind Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.jbiomech.2019.03.023 IS - Early view PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jayaraman, Chandrasekaran A1 - Mummidisetty, Chaitanya Krishna A1 - Loesch, Alexandra A1 - Kaur, Sandi A1 - Hoppe-Ludwig, Shenan A1 - Staat, Manfred A1 - Jayaraman, Arun T1 - Postural and metabolic benefits of using a forearm support walker in older adults with impairments JF - Archives of Physical Medicine and Rehabilitation Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.apmr.2018.10.001 SN - 0003-9993 VL - Volume 100 IS - Issue 4 SP - 638 EP - 647 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Horbach, Andreas A1 - Staat, Manfred A1 - Perez-Viana, Daniel A1 - Simmen, Hans-Peter A1 - Neuhaus, Valentin A1 - Pape, Hans-Christoph A1 - Prescher, Andreas A1 - Ciritsis, Bernhard T1 - Biomechanical in vitro examination of a standardized low-volume tubular femoroplasty JF - Clinical Biomechanics N2 - Background Osteoporosis is associated with the risk of fractures near the hip. Age and comorbidities increase the perioperative risk. Due to the ageing population, fracture of the proximal femur also proves to be a socio-economic problem. Preventive surgical measures have hardly been used so far. Methods 10 pairs of human femora from fresh cadavers were divided into control and low-volume femoroplasty groups and subjected to a Hayes fall-loading fracture test. The results of the respective localization and classification of the fracture site, the Singh index determined by computed tomography (CT) examination and the parameters in terms of fracture force, work to fracture and stiffness were evaluated statistically and with the finite element method. In addition, a finite element parametric study with different position angles and variants of the tubular geometry of the femoroplasty was performed. Findings Compared to the control group, the work to fracture could be increased by 33.2%. The fracture force increased by 19.9%. The used technique and instrumentation proved to be standardized and reproducible with an average poly(methyl methacrylate) volume of 10.5 ml. The parametric study showed the best results for the selected angle and geometry. Interpretation The cadaver studies demonstrated the biomechanical efficacy of the low-volume tubular femoroplasty. The numerical calculations confirmed the optimal choice of positioning as well as the inner and outer diameter of the tube in this setting. The standardized minimally invasive technique with the instruments developed for it could be used in further comparative studies to confirm the measured biomechanical results. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.clinbiomech.2020.105104 VL - 80 IS - Art. 105104 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Horbach, Andreas A1 - Staat, Manfred T1 - Optical strain measurement for the modeling of surgical meshes and their porosity JF - Current Directions in Biomedical Engineering N2 - The porosity of surgical meshes makes them flexible for large elastic deformation and establishes the healing conditions of good tissue in growth. The biomechanic modeling of orthotropic and compressible materials requires new materials models and simulstaneoaus fit of deformation in the load direction as well as trannsversely to to load. This nonlinear modeling can be achieved by an optical deformation measurement. At the same time the full field deformation measurement allows the dermination of the change of porosity with deformation. Also the socalled effective porosity, which has been defined to asses the tisssue interatcion with the mesh implants, can be determined from the global deformation of the surgical meshes. Y1 - 2018 U6 - http://dx.doi.org/10.1515/cdbme-2018-0045 SN - 2364-5504 VL - Band 4 IS - 1 SP - 181 EP - 184 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Horbach, Andreas A1 - Duong, Minh Tuan A1 - Staat, Manfred T1 - Modelling of compressible and orthotropic surgical mesh implants based on optical deformation measurement JF - Journal of the mechanical behavior of biomedical materials Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.jmbbm.2017.06.012 SN - 1751-6161 VL - 74 SP - 400 EP - 410 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hasan, Istabrak A1 - Keil, Ludger A1 - Staat, Manfred A1 - Wahl, Gerhard A1 - Bourauel, Christoph T1 - Determination of the frictional coefficient of the implant-antler interface : experimental approach JF - Biomedical Engineering / Biomedizinische Technik N2 - The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5–0.7 and 0.3–0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens. Y1 - 2012 SN - 1862-278X VL - 57 IS - 5 SP - 359 EP - 363 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Hackl, Michael A1 - Wegmann, Kilian A1 - Kahmann, Stephanie Lucina A1 - Heinze, Nicolai A1 - Staat, Manfred A1 - Neiss, Wolfram F. A1 - Scaal, Martin A1 - Müller, Lars P. T1 - Radial shortening osteotomy reduces radiocapitellar contact pressures while preserving valgus stability of the elbow JF - Knee Surgery, Sports Traumatology, Arthroscopy Y1 - 2017 U6 - http://dx.doi.org/10.1007/s00167-017-4468-z SN - 1433-7347 VL - 25 IS - 7 SP - 2280 EP - 2288 PB - Springer CY - Berlin ER -