TY - BOOK A1 - Pieper, Martin T1 - Quantum mechanics: Introduction to mathematical formulation N2 - Anyone who has always wanted to understand the hieroglyphs on Sheldon's blackboard in the TV series The Big Bang Theory or who wanted to know exactly what the fate of Schrödinger's cat is all about will find a short, descriptive introduction to the world of quantum mechanics in this essential. The text particularly focuses on the mathematical description in the Hilbert space. The content goes beyond popular scientific presentations, but is nevertheless suitable for readers without special prior knowledge thanks to the clear examples. KW - Quantenmechanik KW - Hilbert Room KW - Postulates KW - Schrödingers cat KW - Operators Y1 - 2021 SN - 978-3-658-32644-9 SN - 978-3-658-32645-6 U6 - http://dx.doi.org/10.1007/978-3-658-32645-6 PB - Springer CY - Wiesbaden ER - TY - JOUR A1 - Maezawa, Koichi A1 - Förster, Arnold T1 - Quantum transport devices based on resonant tunneling JF - Nanoelectronics and information technology : advanced electronic materials and novel devices / Rainer Waser (ed.). Y1 - 2003 SN - 3-527-40363-9 SP - 407 EP - 424 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Förster, Arnold A1 - Schmidt, T. A1 - Tewordt, M. A1 - Blick, R. H. T1 - Quantum-dot ground states in a magnetic field studied by single-electron tunneling spectroscopy on double-barrier heterostructures / T. Schmidt ; M. Tewordt ; R. H. Blick ... A. Förster ... JF - Physical Review B . 51 (1995), H. 8 Y1 - 1995 SN - 0163-1829 N1 - 2. ISSN: 1098-0121 ; ISSN der E-Ausg.: 1095-3795 SP - 5570 EP - 5573 ER - TY - JOUR A1 - Förster, Arnold A1 - Lohe, C. A1 - Leuther, A. T1 - Quasi-two-dimensional plasmons of a single δ-doped layer in GaAs studied by high-resolution electron-energy-loss spectroscopy / C. Lohe ; A. Leuther ; A. Förster ... JF - Physical Review B . 47 (1993), H. 7 Y1 - 1993 SN - 0163-1829 N1 - 2. ISSN: 1098-0121 ; ISSN der E-Ausg.: 1095-3795 SP - 3819 EP - 3826 ER - TY - BOOK A1 - Brüssermann, Klaus A1 - Scheider, R. T1 - Radionuklide in Wasser-Schwebstoff-Sediment-Systemen und Abschätzung der Strahlenexposition / [Red.: R. Scheider] Mitarb.: Brüssermann, Klaus Y1 - 1988 SN - 3-437-11196-5 N1 - Veröffentlichungen der Strahlenschutzkommission ; 9 ER - TY - BOOK A1 - Schwarzer, Klemens T1 - Radionuklidtransport im Boden. - Als Ms. gedr. Y1 - 1979 N1 - (Berichte der Kernforschungsanlage Jülich ; 1572). - Zugl.: Aachen, Techn. Hochsch., Fak. für Maschinenwesen, Diss., 1979 PB - Zentralbibliothek der Kernforschungsanlage Jülich CY - Jülich ER - TY - CHAP A1 - Kuperjans, Isabel A1 - Seitz, C.-W. A1 - Wilhelm, H.-G. T1 - Realisierung einer Fernwärmeversorgung mit Kraft-Wärme-Kopplung für den Wohnwertpark Brühl T2 - Energiemanagement in Kommunen und öffentlichen Einrichtungen : Tagung Stuttgart, 16. und 17. September 1998. - (VDI-Berichte ; 1424) Y1 - 1998 SN - 3-18-091424-6 SP - 129 EP - 138 PB - VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Hoyler, Friedrich A1 - Börner, H. G. A1 - Robinson, S. T1 - Recent developments at the ILL (n,γ)-facility JF - Journal of Physics G. 14 (1988), H. S Y1 - 1988 SN - 0305-4616 SP - S161 EP - S165 ER - TY - JOUR A1 - Vogt, C. A1 - Mottaghy, Darius A1 - Wolf, A. A1 - Rath, V. A1 - Pechnig, R. A1 - Clauser, C. T1 - Reducing temperature uncertainties by stochastic geothermal reservoir modelling JF - Geophysical Journal International N2 - Quantifying and minimizing uncertainty is vital for simulating technically and economically successful geothermal reservoirs. To this end, we apply a stochastic modelling sequence, a Monte Carlo study, based on (i) creating an ensemble of possible realizations of a reservoir model, (ii) forward simulation of fluid flow and heat transport, and (iii) constraining post-processing using observed state variables. To generate the ensemble, we use the stochastic algorithm of Sequential Gaussian Simulation and test its potential fitting rock properties, such as thermal conductivity and permeability, of a synthetic reference model and—performing a corresponding forward simulation—state variables such as temperature. The ensemble yields probability distributions of rock properties and state variables at any location inside the reservoir. In addition, we perform a constraining post-processing in order to minimize the uncertainty of the obtained distributions by conditioning the ensemble to observed state variables, in this case temperature. This constraining post-processing works particularly well on systems dominated by fluid flow. The stochastic modelling sequence is applied to a large, steady-state 3-D heat flow model of a reservoir in The Hague, Netherlands. The spatial thermal conductivity distribution is simulated stochastically based on available logging data. Errors of bottom-hole temperatures provide thresholds for the constraining technique performed afterwards. This reduce the temperature uncertainty for the proposed target location significantly from 25 to 12 K (full distribution width) in a depth of 2300 m. Assuming a Gaussian shape of the temperature distribution, the standard deviation is 1.8 K. To allow a more comprehensive approach to quantify uncertainty, we also implement the stochastic simulation of boundary conditions and demonstrate this for the basal specific heat flow in the reservoir of The Hague. As expected, this results in a larger distribution width and hence, a larger, but more realistic uncertainty estimate. However, applying the constraining post-processing the uncertainty is again reduced to the level of the post-processing without stochastic boundary simulation. Thus, constraining post-processing is a suitable tool for reducing uncertainty estimates by observed state variables. Y1 - 2010 U6 - http://dx.doi.org/10.1111/j.1365-246X.2009.04498.x SN - 1365-246X VL - 181 IS - 1 SP - 321 EP - 333 PB - Oxford University Press CY - Oxford ER - TY - CHAP A1 - Pauksztat, Anja A1 - Kuperjans, Isabel A1 - de Hesselle, M. T1 - Referenzformeln für Energiebedarf und CO2-Emissionen in der Glasindustrie T2 - Energieeffizienz - Chancen für die Zukunft : Tagung Berlin, 14. und 15. November 2006. - (VDI-Berichte ; 1951) Y1 - 2006 SN - 3-18-091951-5 SP - 179 EP - 190 PB - VDI-Verl. CY - Düsseldorf ET - Nichtred. Ms.-Dr. ER - TY - JOUR A1 - Förster, Arnold A1 - Schäpers, T. A1 - Müller, F. A1 - Lengeler, B. T1 - Reflection and transmission of ballistic electrons at a potential barrier / Schäpers, T. ; Müller, F. ; Förster, A. ; Lengeler, B. ; Lüth, H. JF - Superlattices and microstructures . 14 (1993), H. 1 Y1 - 1993 SN - 0749-6036 SP - 57 ER - TY - CHAP A1 - Milkova, Kristina A1 - Butenweg, Christoph A1 - Dumova-Jovanoska, Elena T1 - Region-sensitive comprehensive procedure for determination of seismic fragility curves T2 - 1st Croatian Conference on Earthquake Engineering 1CroCEE 22-24 March 2021 Zagreb, Croatia N2 - Seismic vulnerability estimation of existing structures is unquestionably interesting topic of high priority, particularly after earthquake events. Having in mind the vast number of old masonry buildings in North Macedonia serving as public institutions, it is evident that the structural assessment of these buildings is an issue of great importance. In this paper, a comprehensive methodology for the development of seismic fragility curves of existing masonry buildings is presented. A scenario – based method that incorporates the knowledge of the tectonic style of the considered region, the active fault characterization, the earth crust model and the historical seismicity (determined via the Neo Deterministic approach) is used for calculation of the necessary response spectra. The capacity of the investigated masonry buildings has been determined by using nonlinear static analysis. MINEA software (SDA Engineering) is used for verification of the structural safety of the structures Performance point, obtained from the intersection of the capacity of the building and the spectra used, is selected as a response parameter. The thresholds of the spectral displacement are obtained by splitting the capacity curve into five parts, utilizing empirical formulas which are represented as a function of yield displacement and ultimate displacement. As a result, four levels of damage limit states are determined. A maximum likelihood estimation procedure for the process of fragility curves determination is noted as a final step in the proposed procedure. As a result, region specific series of vulnerability curves for structures are defined. KW - seismic risk KW - seismic vulnerability KW - fragility curves KW - masonry structures Y1 - 2021 U6 - http://dx.doi.org/10.5592/CO/1CroCEE.2021.158 SP - 121 EP - 128 PB - University of Zagreb CY - Zagreb ER - TY - JOUR A1 - Thielemann, Frank A1 - Staudt, Erich T1 - Reicht die Kompetenz zur Innovation? Staudt, E.; Thielemann, F. JF - OP DruckMagazin. 39 (1997), H. 10 Y1 - 1997 SN - 0030-0594 SP - 30 EP - 32 ER - TY - CHAP A1 - Stollenwerk, Dominik A1 - Kuvarakul, T. A1 - Kuperjans, Isabel T1 - Renewable energy supply for power dominated, energy intense production processes - a systematic conversion approach for the anodizing process T2 - IOP conference series: Earth and environmental science (EES) Y1 - 2013 SN - 1755-1315 SN - 1755-1307 VL - Vol. 16 IS - H. 1 SP - 012142/1 EP - 012142/4 ER - TY - CHAP A1 - Hartung, I. A1 - Dilger, Klaus A1 - Hellmanns, Mark A1 - Böhme, Stefan T1 - Repair of non-weldable steel structures to extend the life cycle T2 - Proceedings of the IIW International Conference on Advances in Welding and Allied Technologies : July 16 - 17, 2009, Singapore. (Welding in the world ; 53.2009, special issue) Y1 - 2009 SN - 978-981-08-3259-9 SP - 569 EP - 574 PB - Springer CY - Berlin [u.a.] ER - TY - JOUR A1 - Helsper, Christoph A1 - Mölter, W. A1 - Haller, P. T1 - Representative Dilution of Aerosols by a Factor of 10,000 JF - Journal of Aerosol Science. 21 (1990), H. Suppl. 1 Y1 - 1990 SN - 0021-8502 SP - 637 EP - 640 ER - TY - CHAP A1 - Cresser, J. D. A1 - Häger, J. A1 - Leuchs, G. A1 - Rateike, Franz-Matthias A1 - Walther, H. T1 - Resonance fluorescence of atoms in strong monochromatic laser fields T2 - Dissipative systems in quantum optics. Ed. by Rodolfo Bonifacio. Topics in current physics. Vol. 27 N2 - The investigation of atomic resonance fluorescence has always been of special interest as a means for the determination of atomic parameters. In addition, information on the interaction mechanism between atoms and radiation can be obtained. In the standard fluorescence experiment the frequency distribution of the incident photons is larger than the natural width of the respective transition; as a consequence the correlation time in the photon-atom interaction is determined by the lifetime of the atoms in the excited state. With the development of lasers and especially of tunable dye lasers in recent years it became possible to study the case where the incident radiation has a spectral distribution which is narrower than the natural width. This corresponds to a correlation time of the incoming light wave which is much longer than the excited-state lifetime. In this chapter a survey of experiments on the resonance fluorescence of atoms in monochromatic laser fields will be given. Y1 - 1982 SN - 978-3-642-81719-9 U6 - http://dx.doi.org/10.1007/978-3-642-81717-5_3 SP - 21 EP - 59 PB - Springer CY - Berlin ER - TY - JOUR A1 - Vitusevich, S. A. A1 - Förster, Arnold A1 - Lüth, H. A1 - Belyaev, A. E. A1 - Danylyuk, S. V. A1 - Konakova, R. V. A1 - Sheka, D. I. T1 - Resonant spectroscopy of electric-field-induced superlattices JF - Journal of Applied Physics. 90 (2001), H. 6 Y1 - 2001 SN - 1089-7550 U6 - http://dx.doi.org/10.1063/1.1392956 SP - 2857 EP - 2861 ER - TY - JOUR A1 - Förster, Arnold T1 - Resonant tunneling diodes : the effect of structural properties on their performance JF - Festkörperprobleme = Advances in solid state physics. 33 (1994) Y1 - 1994 SN - 0065-3357 N1 - Review ; 2. ISSN: 0430-3393 SP - 37 EP - 62 ER - TY - JOUR A1 - Förster, Arnold T1 - Resonant tunneling diodes operating as modern quantum transport devices JF - Proceedings of the Tenth International Workshop on the Physics of Semiconductor Devices : (December 14 - 18, 1999) / ed.: Vikram Kumar ... - Vol. 2 Y1 - 2000 SN - 81-7023-998-2 N1 - International Workshop on the Physics of Semiconductor Devices <10, 1999, Delhi> SP - 966 EP - 966 PB - Allied Publ. CY - New Delhi [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Vitusevich, S. A. A1 - Belyaev, A. E. A1 - Sheka, D. I. T1 - Resonant tunneling effect in a periodically modulated electrical field. Vitusevich, S.A.; Forster, A.; Belyaev, A.E.; Sheka, D.I.; Luth, H.; Klein, N.; Danylyuk, S.V.; Konakova, R. JF - Proceedings of the Tenth International Conference on Modulated Semiconductor Structures : held at the Johannes Kepler University, Linz, Austria, July 23 - 27, 2001 / MSS 10. Guest ed.: Günther Bauer ... Y1 - 2002 N1 - International Conference on Modulated Semiconductor Structures ; (10, 2001, Linz). Zugleich: Physica E: Low-dimensional Systems and Nanostructures. 13(2002)2-4. ISSN 1386-9477 SP - 811 EP - 813 PB - Elsevier CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Vitusevich, S. A. A1 - Belyaev, A. E. A1 - Indlekofer, K. M. T1 - Resonant tunneling effect in delta p-n GaAs junction. Vitusevich, S. A.; Förster, A.; Belyaev, A. E.; Indlekofer, K. M.; Lüth, H.; Konakova, R. V. JF - Microelectronic Engineering. 46 (1999), H. 1-4 Y1 - 1999 SN - 0167-9317 N1 - International Conference on Micro- and Nanofabrication SP - 169 EP - 172 ER - TY - JOUR A1 - Förster, Arnold A1 - Wensorra, J. A1 - Indlekofer, K. M. A1 - Lüth, H. T1 - Resonant tunneling in nanocolumns improved by quantum collimation. Wensorra, J.; Indlekofer, K. M.; Förster, A.; Lüth, H. JF - Nano Letters. 5 (2005) Y1 - 2005 SN - 0587-4246 SP - 2470 EP - 2475 ER - TY - JOUR A1 - Helsper, Christoph A1 - Fißan, H. J. T1 - Response Characteristic of a Polytec HC-15 Optical Particle Counter JF - Aerosols in science, medicine and technology : Physical and chemical properties of aerosols : Association for Aerosol Research: annual conference. 1980 : Gesellschaft für Aerosolforschung: annual conference. 1980 : Aerosols in science, medicine and technology : Physical and chemical properties of aerosols : Associa-tion for Aerosol Research: annual conference. 1980 : Gesellschaft für Aerosolforschung: annual conference. 1980 : Schmallenberg, 22.10.80 - 24.10.80 Y1 - 1981 N1 - Journal of aerosol science. Volume 0012 ; no 003 SP - 287 EP - 292 PB - Pergamon Pr. CY - Oxford ER - TY - JOUR A1 - Helsper, Christoph A1 - Bartz, H. A1 - Fißan, H. J. A1 - Kousaka, Y. (u.a.) T1 - Response Characteristics for Four Condensation Nucleus Counters to Particles in the 3 to 50 nm Diameter Range / Bartz, H. ; Fißan, H. J. ; Helsper, C.; Kousaka, Y. ; Okuyama, K. ; Keady, R. Fruin, S. ; McMurry, P. H.; Pui, D. Y. H. ; Stolzenburg, M. R. JF - Journal of Aerosol Science. 16 (1985), H. 5 Y1 - 1985 SN - 0021-8502 SP - 443 EP - 456 ER - TY - JOUR A1 - Hoffschmidt, Bernhard A1 - Krüger, D. A1 - Hennecke, K. T1 - Results from parabolic trough systems for process heat at the DLR Cologne / D. Krüger ; B. Hoffschmidt ; K. Hennecke ... JF - Solar thermal 2000 : proceedings of the 10th SolarPACES International Symposium on Solar Thermal Concentrating Technologies, Sydney, Australia, 8 - 10 March 2000 ; part of the Y1 - 2000 N1 - International Symposium on Solar Thermal Concentrating Technologies <10, 2000, Sydney> SP - 113 EP - 120 CY - Sydney ER - TY - JOUR A1 - Sattler, Johannes, Christoph A1 - Röger, Marc A1 - Schwarzbözl, Peter A1 - Buck, Reiner A1 - Macke, Ansgar A1 - Raeder, Christian A1 - Göttsche, Joachim T1 - Review of heliostat calibration and tracking control methods JF - Solar Energy N2 - Large scale central receiver systems typically deploy between thousands to more than a hundred thousand heliostats. During solar operation, each heliostat is aligned individually in such a way that the overall surface normal bisects the angle between the sun’s position and the aim point coordinate on the receiver. Due to various tracking error sources, achieving accurate alignment ≤1 mrad for all the heliostats with respect to the aim points on the receiver without a calibration system can be regarded as unrealistic. Therefore, a calibration system is necessary not only to improve the aiming accuracy for achieving desired flux distributions but also to reduce or eliminate spillage. An overview of current larger-scale central receiver systems (CRS), tracking error sources and the basic requirements of an ideal calibration system is presented. Leading up to the main topic, a description of general and specific terms on the topics heliostat calibration and tracking control clarifies the terminology used in this work. Various figures illustrate the signal flows along various typical components as well as the corresponding monitoring or measuring devices that indicate or measure along the signal (or effect) chain. The numerous calibration systems are described in detail and classified in groups. Two tables allow the juxtaposition of the calibration methods for a better comparison. In an assessment, the advantages and disadvantages of individual calibration methods are presented. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.solener.2020.06.030 VL - 207 SP - 110 EP - 132 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Borchert, Jörg A1 - Lintzel, P. ED - Zenke, Ines T1 - Risiken des Handels T2 - Energiehandel in Europa Y1 - 2012 SN - 978-3-9813142-9-8 SP - 303 EP - 312 PB - Beck CY - München ET - 3. Aufl. ER - TY - CHAP A1 - Lintzel, P. A1 - Borchert, Jörg ED - Zenke, Ines T1 - Risiken des Handels T2 - Energiehandel in Europa Y1 - 2009 SN - 978-3-406-58373-5 SP - 239 EP - 247 PB - Beck CY - München ET - 2. Aufl. ER - TY - CHAP A1 - Borchert, Jörg A1 - Schemm, R. A1 - Lintzel, P. ED - Zenke, Ines T1 - Risiken des Handelsgeschäftes T2 - Energiehandel in Europa Y1 - 2005 SN - 3-406-52443-5 SP - 218 EP - 235 PB - Beck CY - München ER - TY - JOUR A1 - Thielemann, Frank A1 - Lüdtke, C. T1 - Risikomanagement - Aufbau eines Frühwarnsystems JF - Wirtschafts-Nachrichten. 45 (2000), H. 12 Y1 - 2000 SN - 1436-5588 SP - 14 EP - ff ER - TY - CHAP A1 - Kern, Alexander T1 - Risikomanagement : Abschätzung des Schadensrisikos für bauliche Anlagen - Die neue Vornorm DIN V VDE V 0185 Teil 2 : 2002 N2 - Alle Unternehmen sind vielfältigen Risiken ausgesetzt, die Finanz- und Betriebsbereiche einschließlich Dienstleistungen betreffen können. Die Firmen müssen üblicherweise Risiken eingehen, um im Wettbewerb bestehen zu können. Entscheidend ist, dass man sich über die Risiken bewusst ist, diese einschätzen und kontrollieren kann. Falsche Einschätzungen, Versäumnisse und Fehlentscheidungen können empfindliche finanzielle Schäden bis hin zum Totalverlust nach sich ziehen. Ein effektives Risikomanagement ist heute als wichtiger Sicherheitsfaktor anzusehen und sollte zur strategischen Unternehmensführung gehören. Ein vorausschauendes Risikomanagement beinhaltet, Risiken für das Unternehmen zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent, welche Risiken sinnvollerweise über Versicherungen abgedeckt werden sollten. Beim Versicherungsmanagement ist jedoch zu bedenken, dass zur Erreichung bestimmter Ziele Versicherungen nicht geeignet sind (z.B. Erhaltung der Lieferfähigkeit). Eintrittswahrscheinlichkeiten bestimmter Risiken lassen sich durch Versicherungen nicht verändern. Bei Unternehmen, die mit umfangreichen elektronischen Einrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nicht-Verfügbarkeit der elektronischen Einrichtungen und damit der Produktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardware-Schaden an der betroffenen Anlage oft bei weitem übersteigt. Im Blitzschutz gewinnt innovatives Denken in Schadensrisiken langsam an Bedeutung. Risikoanalysen haben die Objektivierung und Quantifizierung der Gefährdung von baulichen Anlagen und ihrer Inhalte durch direkte und indirekte Blitzeinschläge zum Ziel. Seinen Niederschlag hat dieses neue Denken in der neuen deutschen Norm DIN V 0185-2 VDE V 0185 Teil 2 gefunden. Die hier vorgegebene Risikoanalyse gewährleistet, dass ein für alle Beteiligten nachvollziehbares Blitzschutz-Konzept erstellt werden kann, das technisch und wirtschaftlich optimiert ist, d.h. bei möglichst geringem Aufwand den notwendigen Schutz gewährleisten kann. Die sich aus der Risikoanalyse ergebenden Schutzmaßnahmen sind dann in den weiteren Normenteilen der neuen Reihe VDE V 0185 detailliert beschrieben. KW - Blitzschutz KW - Risikomanagement KW - Risikoabschätzung KW - Versicherung KW - Lightning protection KW - Risk management KW - Risk assessment ; Insurance Y1 - 2002 ER - TY - JOUR A1 - Kern, Alexander T1 - Risikomanagement für den Blitzschutz - Abschätzung des Blitzschadensrisikos nach der neuen Vornorm VDE V 0185 Teil 2 : 2002 N2 - Ein vorausschauendes Risikomanagement beinhaltet, Risiken zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent,welche Risiken sinnvoll über Versicherungen abgedeckt werden sollten. Bei Unternehmen, die mit umfangreichen elektronischenEinrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nichtverfügbarkeit der elektronischen Einrichtungen und damit derProduktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardwareschaden an der betroffenen Anlage oft bei weitem übersteigt. KW - Blitzschutz KW - Risikomanagement KW - Risikoabschätzung KW - Lightning protection KW - Risk management KW - Risk assessment Y1 - 2003 ER - TY - CHAP A1 - Borchert, Jörg ED - Romeike, Frank T1 - Risikomanagement in der Energiewirtschaft : Eine Risikoanalyse der elektrizitätswirtschaftlichen Wertschöpfungskette T2 - Rechtliche Grundlagen des Risikomanagements : Haftungs- und Strafvermeidung für Corporate Complience Y1 - 2008 SN - 978-350-310647-9 SP - 231 EP - 270 PB - Erich Schmidt CY - Berlin ER - TY - CHAP A1 - Kern, Alexander T1 - Risikomanagement nach DIN V 0185-2 VDE V 0185 Teil 2: 2002-11 - Einige Beispiele und erste Erfahrungen T1 - Risk management based on DIN V 0185-2 VDE V 0185 part 2: 2002-11 - Some examples and first experiences N2 - Die neue Vornorm VDE V 0185 Teil 2 „Risikomanagement: Abschätzung des Schadensrisikos für bauliche Anlagen“ [1] ist seit November 2002 gültig. Sie ermöglicht nicht nur die Ermittlung der Schutzklasse eines Blitzschutzsystems, sondern auch die Untersuchung zur Notwendigkeit anderer Schutzmaßnahmen gegen Blitzeinwirkungen (Überspannungsschutzgeräte in Unterverteilern und/oder an Endgeräten, Schirmung des Gebäudes und/oder interner Räume, Potentialsteuerung, Brandmelde- und Feuerlöscheinrichtungen, etc.) nach objektiven Kriterien und damit in einer für alle Beteiligten grundsätzlich nachvollziehbaren Art und Weise. Dass eine solche Analyse rel. komplex sein muss und der intensiven Beschäftigung bedarf, ist deshalb nicht verwunderlich. Die Komplexität des Verfahrens sollte allerdings nicht dazu führen, die Vornorm als Ganzes abzulehnen. Die Vornorm beruht auf dem Stand der Diskussion im internationalen Normengremium IEC TC81 WG9 Ende des Jahres 2000. Integriert wurden einige nationale Besonderheiten, die aus Sicht des zuständigen Normenkomitees DKE K251 erforderlich erschienen. In Deutschland konnten und können nun erste breite Erfahrungen in der Anwendung dieser Risikoanalyse gesammelt werden; in anderen Ländern ist dies noch nicht möglich. Diese Erfahrungen können dann, nach Diskussion im nationalen Rahmen, in die internationale Normenarbeit eingebracht werden. Im folgenden Beitrag sollen einige, seit Erscheinen der Vornorm oft wiederkehrende Fragen dargestellt und Lösungsvorschläge vorgestellt werden. Dabei wird auch auf die Tendenzen im internationalen Normengremium IEC TC81 WG9 eingegangen, d.h. auf den aktuellen Entwurf zur IEC 62305-2 [3]. Die Lösungsvorschläge werden begründet, sind allerdings weitestgehend subjektive Meinung des Autors. Für übliche bauliche Anlagen ist die Anwendung der Vornorm rel. einfach möglich. Auch für spezielle Fälle können die darin festgelegten Verfahren herangezogen werden; allerdings sind dann einige weiterführende Überlegungen notwendig, die der Planer von Blitzschutzsystemen durchführen muss. Anhand zweier Beispiele soll die Anwendung der VDE V 0185 Teil 2 auf solche speziellen Fälle dargestellt werden. KW - Blitzschutz KW - Risikomanagement KW - Lightning protection KW - risk management Y1 - 2003 ER - TY - CHAP A1 - Nabe, C. A1 - Borchert, Jörg ED - Hake, Jürgen-Friedrich T1 - Risikomanagement von EVU in liberalisierten Strommärkten T2 - Liberalisierung des Energiemarktes : Vortragsmanuskripte des 5. Ferienkurses "Energieforschung" vom 27. September - 1. Oktober 1999 im Congrescentrum Rolduc und im Forschungszentrum Jülich Y1 - 1999 SN - 3-89336-248-7 N1 - Schriften des Forschungszentrums Jülich : Reie Energietechnik ; 8 SP - 203 EP - 216 PB - Forschungszentrum CY - Jülich ER - TY - CHAP A1 - Kern, Alexander A1 - Braun, Christian T1 - Risk management according to IEC 62305-2 edition 2: 2010–12 assessment of structures with a risk of explosion T2 - 2014 International Conference on Lightning Protection (ICLP), Shanghai, China N2 - Risk management for structures with a risk of explosion should be considered very carefully when performing a risk analysis according to IEC 62305-2. In contrast to the 2006 edition of the standard, the 2010 edition describes the topic “Structures with a risk of explosion” in more detail. Moreover, in Germany separate procedures and parameters are defined for the risk analysis of structures with a risk of explosion (Supplement 3 of the German DIN EN 62305-2 standard). This paper describes the contents and the relevant calculations of this Supplement 3, together with a numerical example. Y1 - 2014 SP - 1237 EP - 1242 ER - TY - BOOK A1 - Gümpel, Paul A1 - Blumhofer, Gunter A1 - Dören, Horst-Peter A1 - Gebel, Wolfgang A1 - Heimann, Winfried A1 - Morach, Rudolf A1 - Schmitz, Karl W. T1 - Rostfreie Stähle : Grundwissen, Konstruktions- und Verarbeitungshinweise Y1 - 2016 SN - 978-3-8169-3148-5 PB - Expertverlag CY - Renningen ET - 5., durchgesehene Aufl. ER - TY - BOOK A1 - Gümpel, Paul A1 - Arlt, Norbert A1 - Dören, Horst-Peter A1 - Heimann, Winfried A1 - Kiesheyer, Heinrich A1 - Schmitz, Karl W. A1 - Uhlig, Georg T1 - Rostfreie Stähle : Grundwissen, Konstruktions- und Verarbeitungshinweise. 3. Aufl. Kontakt & Studium. Bd. 493 Y1 - 2001 SN - 3-8169-1735-6 PB - expert Verl. CY - Renningen ER - TY - BOOK A1 - Gümpel, Paul A1 - Arlt, Norbert A1 - Dören, Horst-Peter A1 - Heimann, Winfried A1 - Kiesheyer, H. A1 - Schmitz, Karl W. A1 - Uhlig, Georg T1 - Rostfreie Stähle. Grundwissen, Konstruktions- und Verarbeitungsweise = Stainless steels. 2., aktualis. Aufl. Kontakt & Studium. Bd. 493 Y1 - 2000 SN - 3-8169-1735-6 PB - Expert-Verl. CY - Renningen ER - TY - BOOK A1 - Gümpel, Paul A1 - Dören, Horst-Peter A1 - Gebel, Wolfgang A1 - Heimann, Winfried A1 - Morath, Rudolf A1 - Schmitz, Karl W. A1 - Uhlig, Georg T1 - Rostfreie Stähle. Grundwissen, Konstruktions- und Verarbeitungsweise = Stainless steels. 4., völlig neu bearb. Aufl. Kontakt & Studium ; Bd. 493 Y1 - 2008 SN - 978-3-8169-2689-4 PB - Expert-Verl. CY - Renningen ER - TY - BOOK A1 - Gümpel, Paul A1 - Arlt, Norbert A1 - Dören, Horst-Peter A1 - Heimann, Winfried A1 - Kiesheyer, H. A1 - Schmitz, Karl W. A1 - Uhlig, Georg T1 - Rostfreie Stähle. Grundwissen, Konstruktions- und Verarbeitungsweise = Stainless steels. Kontakt & Studium. Bd. 493 Y1 - 1996 SN - 3-8169-1080-7 PB - Expert-Verl. CY - Renningen ER - TY - GEN A1 - Erk, Daniel A1 - Klefisch, Andrea A1 - Stellberg, Michael A1 - Zimmer, Dirk T1 - Rückenlehne für einen Fahrzeugsitz Y1 - 2006 ER - TY - CHAP A1 - El-Deib, Khaled A1 - Chudoba, Rostislav A1 - Butenweg, Christoph A1 - Meskouris, Konstantin A1 - Könke, Carsten A1 - Bettzieche, Volker T1 - Safety assessment of rockfill and masonry dams T2 - Structural dynamics - EURODYN 2002 : proceedings of the 4th [i.e. 5th] International Conference on Structural Dynamics, Munich, Germany, 2 - 5 September 2002 / ed. by H. Grundmann ... Vol. 1 Y1 - 2002 SN - 90-5809-510-X SP - 237 EP - 242 PB - Balkema CY - Lisse ER - TY - CHAP A1 - Koller, R. A1 - Stellberg, Michael T1 - Schnappverbindungen T2 - Handbuch der Verbindungstechnik / hrsg. von Carl-Otto Bauer Y1 - 1991 SN - 3-446-14609-1 SP - 294 EP - 324 PB - Hanser CY - München ER - TY - CHAP A1 - Dören, Horst-Peter ED - Gümpel, Paul T1 - Schweißtechnische Verarbeitung nichtrostender Stähle T2 - Rostfreie Stähle. Grundwissen, Konstruktions- und Verarbeitungshinweise Y1 - 2008 SN - 978-3-8169-2689-4 SP - 140 EP - 174 PB - Expert Verlag CY - Renningen ER - TY - CHAP A1 - Meskouris, Konstantin A1 - Holtschoppen, Britta A1 - Butenweg, Christoph A1 - Rosin, Julia T1 - Seismic analysis of liquid storage tanks T2 - Earthquake Geology and Archaeology: Science, Society and Critical facilities : proceedings ; 2nd INQUA-IGCP 567 International Workshop on Active Tectonics, Earthquake Geology, Archaeology and Engineering ; 19-24 September 2011, Corinth (Greece) / Eds.: C. Grützner ; R. Pérez-Lopez ; T. Fernández Steeger ; I. Papanikolaou ; K. Reicherter ; P. G. Silva ; A. Vött. Volume 2 Y1 - 2011 SN - 978-960-466-093-3 SP - 136 EP - 139 PB - The Natural hazards Laboratory, National and Kapodistrian University of Athens CY - Athens ER - TY - CHAP A1 - Meskouris, Konstantin A1 - Butenweg, Christoph A1 - Mistler, Michael A1 - Kuhlmann, Wolfram T1 - Seismic behaviour of historic masonry buildings T2 - 7th National Congress on Mechanics : Chania, Crete, June 24 - 26, 2004 ; proceedings / ed. A. Kounadis .... Y1 - 2004 SP - 47 EP - 49 PB - Hellenic Society for Theoretical and Applied Mechanics CY - Chania ER - TY - CHAP A1 - Marinkovic, Marko A1 - Butenweg, Christoph T1 - Seismic behaviour of RC frames with uncoupled masonry infills having two storeys or two bays T2 - 17th International Conference -From historical to sustainable masonry, Krakow, Poland, July 5-8, 2020 Y1 - 2020 U6 - http://dx.doi.org/10.1201/9781003098508-72 SP - 1 EP - 7 ER - TY - CHAP A1 - Butenweg, Christoph ED - Vacareanu, Radu ED - Ionescu, Constantin T1 - Seismic design and evaluation of industrial facilities T2 - Progresses in European Earthquake Engineering and Seismology. Third European Conference on Earthquake Engineering and Seismology – Bucharest, 2022 N2 - Industrial facilities must be thoroughly designed to withstand seismic actions as they exhibit an increased loss potential due to the possibly wideranging damage consequences and the valuable process engineering equipment. Past earthquakes showed the social and political consequences of seismic damage to industrial facilities and sensitized the population and politicians worldwide for the possible hazard emanating from industrial facilities. However, a holistic approach for the seismic design of industrial facilities can presently neither be found in national nor in international standards. The introduction of EN 1998-4 of the new generation of Eurocode 8 will improve the normative situation with specific seismic design rules for silos, tanks and pipelines and secondary process components. The article presents essential aspects of the seismic design of industrial facilities based on the new generation of Eurocode 8 using the example of tank structures and secondary process components. The interaction effects of the process components with the primary structure are illustrated by means of the experimental results of a shaking table test of a three story moment resisting steel frame with different process components. Finally, an integrated approach of digital plant models based on building information modelling (BIM) and structural health monitoring (SHM) is presented, which provides not only a reliable decision-making basis for operation, maintenance and repair but also an excellent tool for rapid assessment of seismic damage. KW - Industrial facilities KW - Seismic design KW - Tanks KW - EN 1998-4 KW - Structural health monitoring Y1 - 2022 SN - 978-3-031-15103-3 SN - 978-3-031-15106-4 SN - 978-3-031-15104-0 U6 - http://dx.doi.org/10.1007/978-3-031-15104-0 SN - 2524-342X SN - 2524-3438 N1 - Third European Conference on Earthquake Engineering and Seismology. 04-09.09 Bucharest, Romania. SP - 449 EP - 464 PB - Springer CY - Cham ER - TY - CHAP A1 - Rosin, Julia A1 - Kubalski, Thomas A1 - Butenweg, Christoph T1 - Seismic Design of cylindrical liquid storage tanks T2 - Seismic design of industrial facilities : proceedings of the International Conference on Seismic Design of Industrial Facilities (SeDIF-Conference) ; [Aachen, 26. - 27. September 2013] / Chair of Structural Statics and Dynamics, RWTH Aachen. Sven Klinkel ..., ed. Y1 - 2014 SN - 978-3-658-02810-7 (E-Book) ; 978-3-658-02809-1 (Print) U6 - http://dx.doi.org/10.1007/978-3-658-02810-7_36 SP - 429 EP - 440 PB - Springer Vieweg CY - Wiesbaden ER - TY - BOOK A1 - Klinkel, Sven A1 - Butenweg, Christoph A1 - Lin, Gao A1 - Holtschoppen, Britta T1 - Seismic design of industrial facilities : Proceedings of the International Conference on Seismic Design of Industrial Facilities (SeDIF) / Sven Klinkel, Christoph Butenweg, Gao Lin, Britta Holtschoppen Editors Y1 - 2014 SN - 978-3-658-02809-1 (Print) ; 978-365-80281-0-7 (E-Book) U6 - http://dx.doi.org/10.1007/978-3-658-02810-7 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Butenweg, Christoph A1 - Holtschoppen, Britta T1 - Seismic design of industrial facilities in Germany T2 - Seismic Design of Industrial Facilities : proceedings of the International Conference on Seismic Design of Industrial Facilities (SeDIF-Conference) : Aachen, 26. - 27.9.2013 Y1 - 2014 SN - 978-3-658-02809-1 ; 3-658-02809-2 (Print) ; 978-3-658-02810-7 (E-Book) U6 - http://dx.doi.org/10.1007/978-3-658-02810-7_6 SP - 63 EP - 74 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Reindl, Lukas A1 - Park, Jin A1 - Norda, Hannah A1 - Butenweg, Christoph T1 - Seismic design of masonry walls subject to out-of-plane bending T2 - Proceedings of the Tenth International Conference on Computational Structures Technology : Valencia, Spain, 14 - 17 September 2010 / organised in association with: Universidad Politecnica de Valencia ... Ed. by B. H. V. Topping ... Y1 - 2010 SN - 978-1-905088-36-2 U6 - http://dx.doi.org/10.4203/ccp.93.348 SP - Paper 348 PB - Civil-Comp Press CY - Kippen ER - TY - JOUR A1 - Holtschoppen, Britta A1 - Butenweg, Christoph A1 - Meskouris, Konstantin T1 - Seismic design of non-structural components in industrial facilities JF - International journal of engineering under uncertainty Y1 - 2009 SN - 0975-4806 VL - Volume 1 SP - 1 EP - 13 ER - TY - CHAP A1 - Butenweg, Christoph A1 - Holtschoppen, Britta T1 - Seismic design of structures and components in industrial units T2 - Structural Dynamics with Applications in Earthquake and Wind Engineering N2 - Industrial units consist of the primary load-carrying structure and various process engineering components, the latter being by far the most important in financial terms. In addition, supply structures such as free-standing tanks and silos are usually required for each plant to ensure the supply of material and product storage. Thus, for the earthquake-proof design of industrial plants, design and construction rules are required for the primary structures, the secondary structures and the supply structures. Within the framework of these rules, possible interactions of primary and secondary structures must also be taken into account. Importance factors are used in seismic design in order to take into account the usually higher risk potential of an industrial unit compared to conventional building structures. Industrial facilities must be able to withstand seismic actions because of possibly wide-ranging damage consequences in addition to losses due to production standstill and the destruction of valuable equipment. The chapter presents an integrated concept for the seismic design of industrial units based on current seismic standards and the latest research results. Special attention is devoted to the seismic design of steel thin-walled silos and tank structures. KW - Industrial units KW - Seismic design KW - Tanks KW - Silos KW - Components Y1 - 2019 SN - 978-3-662-57550-5 U6 - http://dx.doi.org/10.1007/978-3-662-57550-5_5 SP - 359 EP - 481 PB - Springer CY - Berlin ER - TY - CHAP A1 - Wagner, R. A1 - Noh, S.-Y. A1 - Butenweg, Christoph A1 - Meskouris, Konstantin T1 - Seismic excited granular material silos T2 - Structural dynamics - EURODYN 2002 : proceedings of the 4th [i.e. 5th] International Conference on Structural Dynamics, Munich, Germany, 2 - 5 September 2002 / ed. by H. Grundmann ... Y1 - 2002 SN - 90-5809-511-8 SP - 253 EP - 258 PB - Balkema CY - Lisse ER - TY - CHAP A1 - Rajan, Sreelakshmy A1 - Holtschoppen, B. A1 - Dalguer, L. A. A1 - Klinkel, S. A1 - Butenweg, Christoph ED - Sas, P. T1 - Seismic fragility analysis of a non-conventional reinforced concrete structure considering different uncertainties T2 - Proceedings of ISMA2016, International Conference on Noise and Vibration Engineering/USD2016, International Conference on Uncertainty in Structural Dynamics, / ISMA 2016, USD 2016 Y1 - 2016 SP - 4213 EP - 4225 PB - KU Leuven CY - Leuven ER - TY - RPRT A1 - Butenweg, Christoph A1 - Kaiser, Diethelm T1 - Seismic hazard harmonisation in Europe (SHARE) : DGEB-Workshop in Frankfurt a.M., Germany, 27. May 2014 / Christoph Butenweg, Diethelm Kaiser (editors) Y1 - 2014 SN - 3-930108-12-7 PB - DGEB CY - Aachen ER - TY - CHAP A1 - Schmitt, Timo A1 - Rosin, Julia A1 - Butenweg, Christoph T1 - Seismic Impact And Design Of Buried Pipelines T2 - 16th European Conference on Earthquake Engineering, Thessaloniki, 18-21 June, 2018 N2 - Seismic design of buried pipeline systems for energy and water supply is not only important for plant and operational safety but also for the maintenance of the supply infrastructure after an earthquake. The present paper shows special issues of the seismic wave impacts on buried pipelines, describes calculation methods, proposes approaches and gives calculation examples. This paper regards the effects of transient displacement differences and resulting tensions within the pipeline due to the wave propagation of the earthquake. However, the presented model can also be used to calculate fault rupture induced displacements. Based on a three-dimensional Finite Element Model parameter studies are performed to show the influence of several parameters such as incoming wave angle, wave velocity, backfill height and synthetic displacement time histories. The interaction between the pipeline and the surrounding soil is modeled with non-linear soil springs and the propagating wave is simulated affecting the pipeline punctually, independently in time and space. Special attention is given to long-distance heat pipeline systems. Here, in regular distances expansion bends are arranged to ensure movements of the pipeline due to high temperature. Such expansion bends are usually designed with small bending radii, which during the earthquake lead to high bending stresses in the cross-section of the pipeline. Finally, an interpretation of the results and recommendations are given for the most critical parameters. Y1 - 2018 N1 - Paper No 10600 SP - 1 EP - 12 ER - TY - CHAP A1 - Rosin, Julia A1 - Butenweg, Christoph T1 - Seismic isolation of cylindrical liquid storage tanks T2 - Proceedings of the 9th European Conference on Structural Dynamics, EURODYN 2014 Porto, Portugal, 30 June - 2 July 2014 / A. Cunha, E. Caetano, .... (eds.) Y1 - 2014 SN - 978-972-752-165-4 SP - 3145 EP - 3152 CY - Porto ER - TY - CHAP A1 - Rosin, Julia A1 - Kubalski, Thomas A1 - Butenweg, Christoph ED - Klinkel, Sven ED - Butenweg, Christoph ED - Lin, Gao ED - Holtschoppen, Britta T1 - Seismic isolation of cylindrical liquid storage tanks T2 - Seismic design of industrial facilities N2 - Seismic excited liquid filled tanks are subjected to extreme loading due to hydrodynamic pressures, which can lead to nonlinear stability failure of the thinwalled cylindrical tanks, as it is known from past earthquakes. A significant reduction of the seismically induced loads can be obtained by the application of base isolation systems, which have to be designed carefully with respect to the modified hydrodynamic behaviour of the tank in interaction with the liquid. For this reason a highly sophisticated fluid-structure interaction model has to be applied for a realistic simulation of the overall dynamic system. In the following, such a model is presented and compared with the results of simplified mathematical models for rigidly supported tanks. Finally, it is examined to what extent a simple mechanical model can represent the behaviour of a base isolated tank in case of seismic excitation Y1 - 2013 SN - 978-3-658-02810-7 SN - 978-3-658-02809-1 SN - 978-3-658-14037-3 U6 - http://dx.doi.org/10.1007/978-3-658-02810-7_36 N1 - International Conference on Seismic Design of Industrial Facilities, Aachen, Germany, 26.-27.09.2013. https://sedif-conference.jimdofree.com/ SP - 429 EP - 440 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Butenweg, Christoph A1 - Bursi, Oreste S. A1 - Paolacci, Fabrizio A1 - Marinković, Marko A1 - Lanese, Igor A1 - Nardin, Chiara A1 - Quinci, Gianluca ED - Yang, J. T1 - Seismic performance of an industrial multi-storey frame structure with process equipment subjected to shake table testing JF - Engineering Structures N2 - Past earthquakes demonstrated the high vulnerability of industrial facilities equipped with complex process technologies leading to serious damage of process equipment and multiple and simultaneous release of hazardous substances. Nonetheless, current standards for seismic design of industrial facilities are considered inadequate to guarantee proper safety conditions against exceptional events entailing loss of containment and related consequences. On these premises, the SPIF project -Seismic Performance of Multi-Component Systems in Special Risk Industrial Facilities- was proposed within the framework of the European H2020 SERA funding scheme. In detail, the objective of the SPIF project is the investigation of the seismic behaviour of a representative industrial multi-storey frame structure equipped with complex process components by means of shaking table tests. Along this main vein and in a performance-based design perspective, the issues investigated in depth are the interaction between a primary moment resisting frame (MRF) steel structure and secondary process components that influence the performance of the whole system; and a proper check of floor spectra predictions. The evaluation of experimental data clearly shows a favourable performance of the MRF structure, some weaknesses of local details due to the interaction between floor crossbeams and process components and, finally, the overconservatism of current design standards w.r.t. floor spectra predictions. KW - Multi-storey KW - Frame structure KW - Earthquake KW - Tank KW - Piping Y1 - 2021 U6 - http://dx.doi.org/10.1016/j.engstruct.2021.112681 SN - 0141-0296 VL - 243 IS - 15 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Butenweg, Christoph A1 - Marinković, Marko A1 - Pavese, Alberto A1 - Lanese, Igor A1 - Hoffmeister, Benno A1 - Pinkawa, Marius A1 - Vulcu, Mihai-Cristian A1 - Bursi, Oreste A1 - Nardin, Chiara A1 - Paolacci, Fabrizio A1 - Quinci, Gianluca A1 - Fragiadakis, Michalis A1 - Weber, Felix A1 - Huber, Peter A1 - Renault, Philippe A1 - Gündel, Max A1 - Dyke, Shirley A1 - Ciucci, M. A1 - Marino, A. T1 - Seismic performance of multi-component systems in special risk industrial facilities T2 - 17. World Conference on Earthquake Engineering , Sendai , Japan , 17WCEE , 2021-09-27 - 2021-10-02 N2 - Past earthquakes demonstrated the high vulnerability of industrial facilities equipped with complex process technologies leading to serious damage of the process equipment and multiple and simultaneous release of hazardous substances in industrial facilities. Nevertheless, the design of industrial plants is inadequately described in recent codes and guidelines, as they do not consider the dynamic interaction between the structure and the installations and thus the effect of seismic response of the installations on the response of the structure and vice versa. The current code-based approach for the seismic design of industrial facilities is considered not enough for ensure proper safety conditions against exceptional event entailing loss of content and related consequences. Accordingly, SPIF project (Seismic Performance of Multi- Component Systems in Special Risk Industrial Facilities) was proposed within the framework of the European H2020 - SERA funding scheme (Seismology and Earthquake Engineering Research Infrastructure Alliance for Europe). The objective of the SPIF project is the investigation of the seismic behavior of a representative industrial structure equipped with complex process technology by means of shaking table tests. The test structure is a three-story moment resisting steel frame with vertical and horizontal vessels and cabinets, arranged on the three levels and connected by pipes. The dynamic behavior of the test structure and installations is investigated with and without base isolation. Furthermore, both firmly anchored and isolated components are taken into account to compare their dynamic behavior and interactions with each other. Artificial and synthetic ground motions are applied to study the seismic response at different PGA levels. After each test, dynamic identification measurements are carried out to characterize the system condition. The contribution presents the numerical simulations to calibrate the tests on the prototype, the experimental setup of the investigated structure and installations, selected measurement data and finally describes preliminary experimental results. KW - industrial facilities KW - piping KW - installations KW - seismic loading KW - earthquakes Y1 - 2021 ER - TY - CHAP A1 - Butenweg, Christoph A1 - Mistler, Michael T1 - Seismic resistance of unreinforced masonry buildings T2 - Proceedings of the Eighth International Conference on Computational Structures Technology : [Las Palmas de Cran Canaria, 12-15 September 2006] / ed. by B. H. V. Topping ... Y1 - 2006 SN - 1-905088-06-X U6 - http://dx.doi.org/10.4203/ccp.83.9 SP - Paper 9 PB - Civil-Comp Press CY - Stirling ER - TY - JOUR A1 - Mykoniou, Konstantin A1 - Butenweg, Christoph A1 - Holtschoppen, Britta A1 - Klinkel, Sven T1 - Seismic response analysis of adjacent liquid-storage tanks JF - Earthquake engineering and structural dynamics N2 - A refined substructure technique in the frequency domain is developed, which permits consideration of the interaction effects among adjacent containers through the supporting deformable soil medium. The tank-liquid systems are represented by means of mechanical models, whereas discrete springs and dashpots stand for the soil beneath the foundations. The proposed model is employed to assess the responses of adjacent circular, cylindrical tanks for harmonic and seismic excitations over wide range of tank proportions and soil conditions. The influence of the number, spatial arrangement of the containers and their distance on the overall system's behavior is addressed. The results indicate that the cross-interaction effects can substantially alter the impulsive components of response of each individual element in a tank farm. The degree of this impact is primarily controlled by the tank proportions and the proximity of the predominant natural frequencies of the shell-liquid-soil systems and the input seismic motion. The group effects should be not a priori disregarded, unless the tanks are founded on shallow soil deposit overlying very stiff material or bedrock. KW - liquid-structure interaction KW - seismic response KW - impulsive effects KW - liquid-storage tank KW - structure-soil-structure interaction Y1 - 2016 U6 - http://dx.doi.org/10.1002/eqe.2726 SN - 1096-9845 (E-Journal); 0098-8847 (Print) VL - 45 IS - 11 SP - 1779 EP - 1796 PB - Wiley-VCH CY - Weinheim ER - TY - CHAP A1 - Butenweg, Christoph A1 - Rosin, Julia A1 - Kubalski, Thomas T1 - Seismic response of conventional and base-isolated liquid storage tanks T2 - International Conference on Earthquake Engineering : 29.-31.05.2013, Skopje, Mazedonien Y1 - 2013 SP - 1 EP - 8 ER - TY - CHAP A1 - Cacciatore, Pamela A1 - Butenweg, Christoph T1 - Seismic safety of cylindrical granular material steel silos under seismic loading T2 - Seismic design of industrial facilities 2020: proceedings of the 2nd International Conference on Seismic Design of Industrial Facilities (SeDIF-Conference) Y1 - 2020 SN - 978-3-86359-729-0 SP - 231 EP - 244 ER - TY - CHAP A1 - Gellert, Christoph A1 - Park, Jin A1 - Butenweg, Christoph T1 - Seismic safety verification of masonry structures T2 - Proceedings of the Eight International Masonry Conference : held in Dresden from 4th to 7th of July 2010 / [International Masonry Society ; Technische Universität Dresden]. Ed. by: Wolfram Jäger ... Volume 1. (Masonry / International Masonry Society Special Publication ; 11) Y1 - 2010 SN - 978-3-00-031381-3 SP - 813 EP - 822 PB - ARGE 8IMC Dresden CY - Radebeul ER - TY - CHAP A1 - Tomić, Igor A1 - Penna, Andrea A1 - DeJong, Matthew A1 - Butenweg, Christoph A1 - Correia, António A. A1 - Candeias, Paulo X. A1 - Senaldi, Ilaria A1 - Guerrini, Gabriele A1 - Malomo, Daniele A1 - Beyer, Katrin T1 - Seismic testing of adjacent interacting masonry structures T2 - 12th International Conference on Structural Analysis of Historical Constructions (SAHC 2020) N2 - In many historical centres in Europe, stone masonry buildings are part of building aggregates, which developed when the layout of the city or village was densified. In these aggregates, adjacent buildings share structural walls to support floors and roofs. Meanwhile, the masonry walls of the façades of adjacent buildings are often connected by dry joints since adjacent buildings were constructed at different times. Observations after for example the recent Central Italy earthquakes showed that the dry joints between the building units were often the first elements to be damaged. As a result, the joints opened up leading to pounding between the building units and a complicated interaction at floor and roof beam supports. The analysis of such building aggregates is very challenging and modelling guidelines do not exist. Advances in the development of analysis methods have been impeded by the lack of experimental data on the seismic response of such aggregates. The objective of the project AIMS (Seismic Testing of Adjacent Interacting Masonry Structures), included in the H2020 project SERA, is to provide such experimental data by testing an aggregate of two buildings under two horizontal components of dynamic excitation. The test unit is built at half-scale, with a two-storey building and a one-storey building. The buildings share one common wall while the façade walls are connected by dry joints. The floors are at different heights leading to a complex dynamic response of this smallest possible building aggregate. The shake table test is conducted at the LNEC seismic testing facility. The testing sequence comprises four levels of shaking: 25%, 50%, 75% and 100% of nominal shaking table capacity. Extensive instrumentation, including accelerometers, displacement transducers and optical measurement systems, provides detailed information on the building aggregate response. Special attention is paid to the interface opening, the globa KW - Historical centres KW - Stone masonry KW - Adjacent buildings KW - Shake table test Y1 - 2020 U6 - http://dx.doi.org/10.23967/sahc.2021.234 N1 - Wednesday, 16 September, 2020 to Friday, 18 September, 2020, Barcelona. SP - 1 EP - 12 ER - TY - CHAP A1 - Churilov, Sergej A1 - Dumova-Jovanoska, Elena A1 - Butenweg, Christoph ED - Adam, Christoph ED - Heuer, Rudolf ED - Lenhardt, Wolfgang ED - Schranz, Christian T1 - Seismic verification of existing masonry buildings and strengthening with reinforced concrete jackets T2 - Proceedings - Vienna Congress on Recent Advances in Earthquake Engineering and Structural Dynamics 2013 (VEESD 2013) N2 - A methodology for assessment, seismic verification and strengthening of existing masonry buildings is presented in this paper. The verification is performed using a calculation model calibrated with the results from ambient vibration measurements. The calibrated model serves as an input for a deformation-based verification procedure based on the Capacity Spectrum Method (CSM). The bearing capacity of the building is calculated from experimental capacity curves of the individual walls idealized with bilinear elastic-perfectly plastic curves. The experimental capacity curves were obtained from in-plane cyclic loading tests on unreinforced and strengthened masonry walls with reinforced concrete jackets. The seismic action is compared with the load-bearing capacity of the building considering non-linear material behavior with its post-peak capacity. The application of the CSM to masonry buildings and the influence of a traditional strengthening method are demonstrated on the example of a public school building in Skopje, Macedonia. Y1 - 2013 SN - 978-3-902749-04-8 N1 - Vienna Congress on Recent Advances in Earthquake Engineering and Structural Dynamics, Vienna, Austria, Paper No. 523 13. D-A-CH Tagung ; Vienna, Austria, 29. - 30. August 2013 http://hdl.handle.net/20.500.12188/15830 (Error - Cannot Connect to Server) ER - TY - CHAP A1 - Renault, Philippe A1 - Butenweg, Christoph T1 - Seismic vulnerability assessment of bridges T2 - First Munich Bridge Assessment Conference, MBAC 2005 : Munich, 20.-25. June 2005 Y1 - 2005 SP - 1 EP - 16 ER - TY - CHAP A1 - Butenweg, Christoph A1 - Kuhlmann, Winfried A1 - Lopez, M. A1 - Fernandez, S. T1 - Seismic vulnerability assessment of the Aachen Cathedral based on measurements and numerical simulations T2 - International Conference on Earthquake Engineering to mark 40 years from Catastrophic 1963 Skopje Earthquake, Skopje 2003 Y1 - 2003 SP - 1 EP - 8 ER - TY - CHAP A1 - Kuhlmann, Wolfram A1 - Butenweg, Christoph A1 - Lopez, Marijen A1 - Fernandez, Sebastian T1 - Seismic vulnerability assessment of the historic Aachen Cathedral T2 - Conference proceedings / 13th World Conference on Earthquake Engineering [Vancouver, British Columbia, Canada, August 1 - 6, 2004] / [hosted by CAEE/ACGP, Canadian Association for Earthquake Engineering] Y1 - 2004 SP - 1 EP - 14 PB - CAEE CY - Vancouver ER - TY - CHAP A1 - Renault, Philippe A1 - Butenweg, Christoph A1 - Mistler, Michael T1 - Seismic vulnerability assessment system for bridges T2 - Proceedings of the Tenth International Conference on Civil, Structural and Environmental Engineering Computing : [Rome, Italy, 30. August - 2. September 2005] / ed. by B. H. V. Topping Y1 - 2005 SN - 1-905088-00-0 SP - 1 EP - 14 PB - Civil-Comp Press CY - Stirling ER - TY - CHAP A1 - Meskouris, Konstantin A1 - Holtschoppen, Britta A1 - Butenweg, Christoph A1 - Park, Jin T1 - Seismische Auslegung von Silo- und Tankbauwerken T2 - Festschrift zum 60. Geburtstag von Univ.-Prof. Dr.-Ing. Ingbert Mangerig. (Berichte aus dem konstruktiven Ingenieurbau ; 2010,6) Y1 - 2010 SP - 215 EP - 224 PB - Univ. der Bundeswehr CY - Neubiberg ER - TY - JOUR A1 - Butenweg, Christoph A1 - Schmitt, T. A1 - Rosen, B. T1 - Seismische Einwirkungen auf erdverlegte Rohrleitungen JF - Bauingenieur N2 - Die erdbebensichere Auslegung von erdverlegten Rohrleitungssystemen ist von wesentlicher Bedeutung zur Sicherstellung der Funktionalität der Versorgungsinfrastruktur nach einem Erdbebenereignis. Zur Vermeidung von Netzausfällen ist es erforderlich, die räumlich weit ausgedehnten Leitungssysteme mit geeigneten rechnerischen Modellen seismisch zu bemessen. Der vorliegende Beitrag behandelt die Beanspruchung von Rohrleitungssystemen durch seismische Welleneinwirkung und stellt geeignete Näherungsansätze und ein detailliertes Rechenmodell für seismische Leitungsanalysen vor. Mit den Ansätzen wird in Berechnungsbeispielen der Einfluss wesentlicher Parameter auf die seismisch induzierten Dehnungen in Rohrleitungssystemen untersucht. Y1 - 2014 SN - 0005-6650 N1 - gedruckt in der Bereichsbibliothek Bayernallee unter der Signatur 13 Z 049 vorhanden VL - 89 SP - 316 EP - 324 PB - VDI Fachmedien CY - Düsseldorf ER - TY - JOUR A1 - Butenweg, Christoph A1 - Schmitt, Timo A1 - Rosen, Britta T1 - Seismische Einwirkungen auf erdverlegte Rohrleitungssysteme JF - Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen ; offizielle Zeitschrift der VDI-Gesellschaft Bautechnik Y1 - 2014 SN - 0005-6650 VL - 89 (2014) IS - Heft 7/8 SP - 316 EP - 324 PB - VDI Fachmedien CY - Düsseldorf ER - TY - CHAP A1 - Schmitt, T. A1 - Butenweg, Christoph T1 - Seismische Einwirkungen auf erdverlegte Rohrleitungssysteme – Parameterstudie T2 - Erdbeben und bestehende Bauten : 14. D-A-C-H Tagung 20.08. - 21.08.2015, ETH Zürich. (Dokumentation / SIA ; D 0255) Y1 - 2015 SN - 978-3-03732-060-0 SP - 199 EP - 206 PB - SGEB CY - Zürich ER - TY - CHAP A1 - Butenweg, Christoph A1 - Sadegh-Azar, H. A1 - Meskouris, Konstantin T1 - Seismische Vulnerabilität von bestehenden Bauwerken T2 - 5. Forum und Gefahrentag : auf der Suche nach dem Risiko : ein aktuelles Symposium zu Fragen der Risikowahrnehmung und Katastrophenvorsorge in Deutschland, ZDF Mainz Lerchenberg, 13. - 14. Oktober, 2004 Y1 - 2004 SP - 1 ER - TY - JOUR A1 - Butenweg, Christoph A1 - Rosin, Julia T1 - Seismischer Nachweis von Mauerwerksbauten in deutschen Erdbebengebieten JF - Mauerwerk N2 - Mit finanzieller Unterstützung der Deutschen Gesellschaft für Mauerwerks- und Wohnungsbau e.V. (DGfM) und des Deutschen Instituts für Bautechnik in Berlin (DIBt) wurden zwei aufeinander aufbauende Forschungsvorhaben zur Verbesserung der seismischen Nachweise von Mauerwerksbauten in deutschen Erdbebengebieten durchgeführt. Zunächst wurde das seismische Verhalten von drei modernen unbewehrten Mauerwerksgebäuden in der Region Emilia Romagna in Italien während der Erdbebenserie im Jahr 2012 in Kooperation mit der Universität Pavia eingehend untersucht. Aufbauend auf den Erkenntnissen dieser Untersuchungen wurde ein verbessertes seismisches Bemessungskonzept für unbewehrte Mauerwerksbauten erarbeitet. Der Beitrag stellt die wesentlichen Ergebnisse dieser Forschungsarbeiten und deren Eingang in die Normung vor. Y1 - 2020 U6 - http://dx.doi.org/10.1002/dama.202000006 SN - 1437-1022 VL - 24 IS - 2 SP - 108 EP - 113 PB - Wiley CY - Weinheim ER - TY - CHAP A1 - Michel, P. A1 - Zilligen, H. A1 - Rosin, J. A1 - Butenweg, Christoph T1 - Seismisches Verhalten pfahlgegründeter Tankbauwerke T2 - Erdbeben und bestehende Bauten : 14. D-A-C-H Tagung 20.08. - 21.08.2015, ETH Zürich. (Dokumentation / SIA ; D 0255) Y1 - 2015 SN - 978-3-03732-060-0 SP - 181 EP - 188 PB - SGEB CY - Zürich ER - TY - JOUR A1 - Förster, Arnold A1 - Kordos, P. A1 - Betko, J. T1 - Semi-insulating GaAs layers grown by molecular-beam epitaxy / P. Kordos ; A. Förster ; J. Betko ... JF - Applied physics letters. 67 (1995), H. 7 Y1 - 1995 SN - 0003-6951 N1 - ISSN der E-Ausg.: 1077-3118 SP - 983 EP - 985 ER - TY - JOUR A1 - Keller, Johannes A1 - Rath, Volker A1 - Bruckmann, Johanna A1 - Mottaghy, Darius A1 - Clauser, Christoph A1 - Wolf, Andreas A1 - Seidler, Ralf A1 - Bücker, H. Martin A1 - Klitzsch, Norbert T1 - SHEMAT-Suite: An open-source code for simulating flow, heat and species transport in porous media JF - SoftwareX N2 - SHEMAT-Suite is a finite-difference open-source code for simulating coupled flow, heat and species transport in porous media. The code, written in Fortran-95, originates from geoscientific research in the fields of geothermics and hydrogeology. It comprises: (1) a versatile handling of input and output, (2) a modular framework for subsurface parameter modeling, (3) a multi-level OpenMP parallelization, (4) parameter estimation and data assimilation by stochastic approaches (Monte Carlo, Ensemble Kalman filter) and by deterministic Bayesian approaches based on automatic differentiation for calculating exact (truncation error-free) derivatives of the forward code. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.softx.2020.100533 SN - 2352-7110 VL - 12 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kern, Alexander A1 - Zischank, Wolfgang J. A1 - Heidler, Fridolin A1 - Wiesinger, J. [u.a.] T1 - Shielding effectiveness of reinforced concrete cable ducts carrying partial lightning currents JF - Conference proceedings : 14th - 18th September 1998, [Burlington Hotel, Birmingham, United Kingdom] / organised by: School of Engineering and Advanced Technology, Staffordshire University, United Kingdom Y1 - 1998 N1 - International Conference on Lightning Protection <24, 1998, Birmingham> ; School of Engineering and Advanced Technology ; ICLP <4, 1998, Birmingham> CY - Birmingham ER - TY - BOOK A1 - Breitbach, Gerd A1 - Wolters, Johannes T1 - Sicherheitstechnische Untersuchungen zum Störfallverhalten des HTR-100 : Ergänzungsband mit vertiefenden Einzelbeiträgen zum Bericht Jül-Spez-477 / J. Wolters ... G. Breitbach ... Y1 - 1991 N1 - (Berichte des Forschungszentrums Jülich ; 2539) PB - Forschungszentrum Jülich, Zentralbibliothek CY - Jülich ER - TY - BOOK A1 - Breitbach, Gerd A1 - Altes, Jürgen A1 - David, H.-P. T1 - Sicherheitstechnische Untersuchungen zum Störfallverhalten des HTR-500 : Erg.-Bd. mit vertiefenden Einzelbeitr. zum Bericht Jül-Spez-220 / [Kernforschungsanlage Jülich GmbH, Inst. für Nukleare Sicherheitsforschung]. Von J. Altes ; G. Breitbach ; H.-P. David ... Y1 - 1984 N1 - Literaturangaben. - Bildet d. Erg. zu: Zum Störverhalten des HTR 500. - Als Ms. gedr. PB - Zentralbibliothek der Kernforschungsanlage CY - Jülich ER - TY - BOOK A1 - Breitbach, Gerd A1 - Mertens, J. [Hrsg.] T1 - Sicherheitstechnische Untersuchungen zum Störfallverhalten des HTR-Modul / [KFA, Kernforschungsanlage Jülich, GmbH, Inst. für Nukleare Sicherheitsforschung]. Von G. Breitbach ... Zsgest. von J. Mertens Y1 - 1985 N1 - (Spezielle Berichte der Kernforschungsanlage Jülich ; 335). - Ergänzungsband mit vertiefenden Einzelbeiträgen zu 'Spezielle Berichte der Kernforschungsanlage Jülich' Bd. 260. - Institut für Nukleare Sicherheitsforschung PB - Zentralbibliothek der Kernforschungsanlage CY - Jülich ER - TY - BOOK A1 - Thielemann, Frank T1 - Sicherung der Wettbewerbsfähigkeit durch zwischenbetriebliche Kooperation Y1 - 1994 N1 - Förderkennzeichen BMBF 01 HK 313; 01 HK 333/2; Input ; [8] PB - IBI - Ges. für Innovationsforschung CY - Düsseldorf [u.a.] ER - TY - JOUR A1 - Schwarzer, Klemens A1 - Müller, C. A1 - Kleine-Hering, H. T1 - Simple solar systems for heating, hot water and cooking in high altitude regions with high solar radiation / C. Müller ; K. Schwarzer ; H. Kleine-Hering JF - Proceedings / organised by: ISES Europe ... [Ed.: Deutsche Gesellschaft für Sonnenenergie e.V. - DGS, Munich ; PSE GmbH - Forschung Entwicklung Marketing, Freiburg]. - Vol 1 Y1 - 2004 SN - 3-9809656-1-9 N1 - EuroSun <5, 2004, Freiburg, Breisgau> ; Internationales Sonnenforum <14, 2004, Freiburg, Breisgau> ; Deutsche Gesellschaft für Sonnenenergie ; CD-ROM-Ausg.: ISBN 3-9809656-4-3 SP - 1-653-1-658 PB - PSE CY - Freiburg [Breisgau] ER - TY - JOUR A1 - Jildeh, Zaid B. A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Pieper, Martin T1 - Simulating the electromagnetic‐thermal treatment of thin aluminium layers for adhesion improvement JF - Physica status solidi (a) N2 - A composite layer material used in packaging industry is made from joining layers of different materials using an adhesive. An important processing step in the production of aluminium-containing composites is the surface treatment and consequent coating of adhesive material on the aluminium surface. To increase adhesion strength between aluminium layer and the adhesive material, the foil is heat treated. For efficient heating, induction heating was considered as state-of-the-art treatment process. Due to the complexity of the heating process and the unpredictable nature of the heating source, the control of the process is not yet optimised. In this work, a finite element analysis of the process was established and various process parameters were studied. The process was simplified and modelled in 3D. The numerical model contains an air domain, an aluminium layer and a copper coil fitted with a magnetic field concentrating material. The effect of changing the speed of the aluminium foil (or rolling speed) was studied with the change of the coil current. Statistical analysis was used for generating a general control equation of coil current with changing rolling speed. Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431893 SN - 1862-6319 VL - Vol. 212 IS - 6 SP - 1234 EP - 1241 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Kern, Alexander T1 - Simulation and measurement of melting effects on metal sheets caused by direct lightning strikes JF - 1991 International Aerospace and Ground Conference on Lightning and Static Electricity : proceedings of a conference ... held at Cocoa Beach, Florida, April 16-19, 1991 / NASA Y1 - 1991 N1 - International Aerospace and Ground Conference on Lightning and Static Electricity <1991, Cocoa Beach, Fla.> ; United States / National Aeronautics and Space Administration CY - Washington, DC ER - TY - CHAP A1 - Behrens, Jörg A1 - Frentzel, Ralf A1 - Kern, Alexander T1 - Simulation der transienten Spannungsverläufe im Eigenbedarfsnetz eines Großkraftwerks bei einem kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung T1 - Simulation of transient voltage curve of a house-load operation net-work of large power plant by a lightning strike in a high-voltage over-head line closed to the power plant N2 - 8. VDE/ABB-Blitzschutztagung, 29. - 30. Oktober 2009 in Neu-Ulm. Blitzschutztagung <8, 2009, Neu-Ulm> Berlin : VDE Verl. 2009 Großkraftwerke können durch Blitzentladungen mit potentiellen Auswirkungen auf deren Verfügbarkeit und Sicherheit gefährdet werden. Ein sehr spezielles Szenario, welches aus aktuellem Anlass zu untersuchen war, betrifft den kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung am Netzanschluss der Anlage. Wird nun noch ein sogenannter Schirmfehler unterstellt, d.h. der direkte Blitzeinschlag erfolgt in ein Leiterseil des Hoch- bzw. Höchstspannungsnetzes und nicht in das darüber gespannte Erdseil, so bedeutet dies eine extreme elektromagnetische Einwirkung. Der vorliegende Beitrag befasst sich mit der Simulation eines solchen Blitzeinschlages und dessen Auswirkungen auf den Netzanschluss und die Komponenten der elektrischen Eigenbedarfsanlagen eines Kraftwerks auf den unterlagerten Spannungsebenen. Die dabei gewonnenen Erkenntnisse lassen sich ohne Einschränkungen auf Industrieanlagen mit Mittelspannungs-Netzanschluss und ohne eigener Stromversorgung übertragen. N2 - Lightning discharge can endanger large power plants with potential influence on their availability and reliability. A very special scenario, which was currently to analyse, is the lightning strike close to the high-voltage overhead line at the grid of the power plant. Supposing a failure of shielding and that the lightning strike goes directly into the line then the elec-tromagnetic effect is extremely high. The following article gives attention to the simulation of lightning strike and their effects to the connection with the grid and the components of the house-load operation of a large power plant especially to the lower voltage level sections. These results are transferable to industrial plants which have no own power supply. KW - Blitzschutz KW - Blitzeinschlag KW - lightning strike Y1 - 2009 SN - 978-3-8007-3197-8 ER - TY - CHAP A1 - Kuhlmann, Wolfram A1 - Butenweg, Christoph A1 - Meskouris, Konstantin A1 - Kempen, Thomas T1 - Simulation des Tragverhaltens des Aachener Doms im Erdbebenfall T2 - Die karolingische Pfalzkapelle in Aachen : Material, Bautechnik, Restaurierung. (Arbeitshefte der rheinischen Denkmalpflege ; 78) Y1 - 2012 SN - 978-3-88462-325-1 SP - 237 EP - 248 PB - Wernersche Verlags-Gesellschaft CY - Worms ER - TY - CHAP A1 - Butenweg, Christoph A1 - Kleemann, Anne A1 - Altay, Okyay A1 - Renault, Philippe T1 - Simulation of impact-loads on reinforced concrete structural elements T2 - 22nd International Conference on Structural Mechanics in Reactor Technology 2013 : (SMiRT 22) ; San Francisco, California, USA, 18 - 23 August 2013 Y1 - 2013 SP - 1 EP - 10 ER - TY - CHAP A1 - Augenstein, Eckardt A1 - Herbergs, S. A1 - Kuperjans, Isabel A1 - Lucas, K. ED - Kjelstrup, Signe T1 - Simulation of industrial energy supply systems with integrated cost optimization T2 - Proceedings of ECOS 2005, the 18th International Conference on Efficiency, Cost, Optimization, Simulation, and Environmental Impact of Energy Systems : Trondheim, Norway, June 20 - 22, 2005. - Vol. 2 Y1 - 2005 SN - 82-519-2041-8 N1 - CD-ROM-Ausg. u.d.T.: Shaping our future energy systems SP - 627 EP - 634 PB - Tapir Academic Press CY - Trondheim ER - TY - JOUR A1 - Kern, Alexander A1 - Frentzel, Ralf A1 - Behrens, Jörg T1 - Simulation of the transient voltages in the auxiliary power network of a large power plant in case of a direct lightning strike to the high-voltage overhead transmission line Y1 - 2010 N1 - 30th International Conference on Lightning Protection, Cagliari (Italien), 2010 SP - 749-1 EP - 749-7 ER - TY - CHAP A1 - El Moussaoui, Noureddine A1 - Kassmi, Khalil A1 - Alexopoulos, Spiros A1 - Schwarzer, Klemens A1 - Chayeb, Hamid A1 - Bachiri, Najib T1 - Simulation studies on a new innovative design of a hybrid solar distiller MSDH alimented with a thermal and photovoltaic energy T2 - Materialstoday: Proceedings Y1 - 2021 U6 - http://dx.doi.org/10.1016/j.matpr.2021.03.115 SN - 2214-7853 ER - TY - CHAP A1 - Butenweg, Christoph A1 - Kleemann, Anne A1 - Altay, Okyay T1 - Simulation von Impact Belastungen auf Stahlbetonstrukturen T2 - 13. D-A-CH Tagung für Erdbebeningenieurwesen und Baudynamik (D-A-CH 2013) : 29.-30. August 2013, Wien, Österreich Y1 - 2013 SP - 1 EP - 9 ER - TY - CHAP A1 - Kuperjans, Isabel A1 - Terpitz, J. A1 - Terruhn, H. A1 - Wilhelm, H.-G. T1 - Simulation zur Konzeption und Analyse betrieblicher und kommunaler Nahwärmesysteme T2 - Betriebliches Energiemanagement : Tagung Cottbus, 30. und 31. März 1999. - (VDI-Berichte ; 1462) Y1 - 1999 SN - 3-18-091462-9 SP - 195 EP - 204 PB - VDI-Verl. CY - Düsseldorf ER -