TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Dammann, Philipp A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T JF - Medical Physics N2 - Purpose: MRI plays a leading diagnostic role in assessing the musculoskeletal (MSK) system and is well established for most questions at clinically used field strengths (up to 3 T). However, there are still limitations in imaging early stages of cartilage degeneration, very fine tendons and ligaments, or in locating nerve lesions, for example. 7 T MRI of the knee has already received increasing attention in the current published literature, but there is a strong need to develop new radiofrequency (RF) coils to assess more regions of the MSK system. In this work, an eight-channel transmit/receive RF array was built as a multipurpose coil for imaging some of the thus far neglected regions. An extensive coil characterization protocol and first in vivo results of the human wrist, shoulder, elbow, knee, and ankle imaged at 7 T will be presented. Methods: Eight surface loop coils with a dimension ofurn:x-wiley:00942405:media:mp7176:mp7176-math-0001 were machined from FR4 circuit board material. To facilitate easy positioning, two coil clusters, each with four loop elements, were combined to one RF transmit/receive array. An overlapped and shifted arrangement of the coil elements was chosen to reduce the mutual inductance between neighboring coils. A phantom made of body-simulating liquid was used for tuning and matching on the bench. Afterward, the S-parameters were verified on a human wrist, elbow, and shoulder. For safety validation, a detailed compliance test was performed including full wave simulations of the RF field distribution and the corresponding specific absorption rate (SAR) for all joints. In vivo images of four volunteers were assessed with gradient echo and spin echo sequences modified to obtain optimal image contrast, full anatomic coverage, and the highest spatial resolution within a reasonable acquisition time. The performance of the RF coil was additionally evaluated by in vivo B1 mapping. Results: A comparison of B1 per unit power, flip angle distribution, and anatomic images showed a fairly homogeneous excitation for the smaller joints (elbow, wrist, and ankle), while for the larger joints, the shoulder and especially the knee, B1 inhomogeneities and limited penetration depth were more pronounced. However, the greater part of the shoulder joint could be imaged.In vivo images rendered very fine anatomic details such as fascicles of the median nerve and the branching of the nerve bundles. High-resolution images of cartilage, labrum, and tendons could be acquired. Additionally, turbo spin echo (TSE) and inversion recovery sequences performed very well. Conclusions: This study demonstrates that the concept of two four-channel transmit/receive RF arrays can be used as a multipurpose coil for high-resolutionin vivo MR imaging of the musculoskeletal system at 7 T. Not only gradient echo but also typical clinical and SAR-intensive sequences such as STIR and TSE performed well. Imaging of small structures and peripheral nerves could in particular benefit from this technique. Y1 - 2010 U6 - https://doi.org/10.1118/1.3517176 SN - 2473-4209 VL - 37 IS - 12 SP - 6368 EP - 6376 PB - Wiley CY - Hoboken, NJ ER - TY - JOUR A1 - Gronsfeld, Richard A1 - Sparla, Peter A1 - Weinnhold, Wolfgang T1 - Airborne und terrestrisches Laserscanning - neue Tools für den Talsperrenbetreiber? JF - Wasserwirtschaft Y1 - 2010 U6 - https://doi.org/10.1007/BF03241621 SN - 0043-0978 VL - 100 IS - 4 SP - 80 EP - 82 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Jacobs, Stephan T1 - Agilität in Großprojekten durch „Integration Driven Design“ : ein Erfahrungsbericht JF - Softwaretechnik-Trends (STT) N2 - Der folgende Bericht fasst Erfahrungen zusammen, die in großen Entwicklungsprojekten der Firma Ericsson über mehrere Jahre gesammelt wurden. Ziel war dabei nicht, agile Methoden und Techniken einzusetzen - Agilität war zu der Zeit noch kein Hype-Thema. Vielmehr wurden Schwächen in den eigenen Projekten identifiziert und verbessert. Der Erfahrungsbericht vergleicht Verbesserungen in diesen Projekten mit den Ansätzen der agilen Entwicklung. Als Ergebnis werden folgende Punkte festgehalten: Erstens, einige Praktiken und Werte der agilen Entwicklung lassen sich auch in Großprojekten einsetzen. Zweitens, bei der Skalierung für Großprojekte werden diese Praktiken langsamer getaktet. Drittens, agile Entwicklung ist nicht nur eine Reihe von Praktiken und Werten, agile Entwicklung ist vielmehr auch eine Frage der Entwicklungs- und Projektkultur. Diese kulturelle Änderung lässt sich in Großprojekten deutlich langsamer umsetzen. Y1 - 2010 SN - 0720-8928 VL - 30 IS - 3 PB - GI - Gesellschaft für Informatik CY - Bonn ER - TY - JOUR A1 - Kozhalakova, A. A. A1 - Zhubanova, Azhar A. A1 - Mansurov, Z. A. A1 - Digel, Ilya A1 - Tazhibayeva, S. M. A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - Adsorption of bacterial lipopolysaccharides on carbonized rice shell JF - Science of Central Asia Y1 - 2010 SP - 50 EP - 54 ER - TY - JOUR A1 - Gebhardt, Andreas A1 - Schmidt, Frank-Michael A1 - Hötter, Jan-Steffen A1 - Sokalla, Wolfgang A1 - Sokalla, Patrick T1 - Additive manufacturing by selective laser melting the realizer desktop machine and its application for the dental industry JF - Physics Procedia N2 - Additive Manufacturing of metal parts by Selective Laser Melting has become a powerful tool for the direct manufacturing of complex parts mainly for the aerospace and medical industry. With the introduction of its desktop machine, Realizer targeted the dental market. The contribution describes the special features of the machine, discusses details of the process and shows manufacturing results focused on metal dental devices. KW - scan strategy KW - dental bridges KW - cobald chrome KW - Selective Laser Melting (SLM) KW - additive manufacturing Y1 - 2010 U6 - https://doi.org/10.1016/j.phpro.2010.08.082 SN - 1875-3892 N1 - Laser Assisted Net Shape Engineering 6, Proceedings of the LANE 2010, Part 2 VL - 5 B IS - 2 SP - 543 EP - 549 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Renz, Wolfgang A1 - de Geyer d'Orth, Thibaut A1 - Dieringer, Matthias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Prothmann, Marcel A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla JF - Journal of Cardiovascular Magnetic Resonance N2 - Background To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms. Results ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms. Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34). Conclusions The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T. KW - Interval Time Series KW - Image Quality Score KW - Image Quality Assessment KW - Sound Pressure Level KW - Cardiovascular Magnetic Resonance Y1 - 2010 U6 - https://doi.org/10.1186/1532-429X-12-67 SN - 1532-429X VL - 12 IS - 1 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Vu, Khoi Duc A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - A primal-dual algorithm for shakedown analysis of elastic-plastic bounded linearly kinematic hardening bodies Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 7 ER - TY - JOUR A1 - Hirschfeld, Julian A. A1 - Lustfeld, Hans A1 - Reißel, Martin A1 - Steffen, Bernhard T1 - A novel scheme for precise diagnostics and effective stabilization of currents in a fuel cell stack JF - International Journal of Energy Research N2 - A novel scheme for detecting inhomogeneous internal currents in a fuel cell stack is presented. In this paper the scheme is investigated for the case that the flow field plates consist of graphite. Then plates of high conductivity, e.g. aluminium between the flow field plates together with small slits in these plates have three effects: (a) Whenever a local inhomogeneity of the electric current occurs at a particular cell in the stack, this will induce a surface current close to that cell perpendicular to the averaged current. This current can be detected. (b) The plates of high conductivity completely prevent the inhomogeneities from spreading to neighbouring cells. (c) Even at the particular cell the inhomogeneity is suppressed as far as possible. Thus this scheme leads to much better diagnostic possibilities and at the same time reduces electric instabilities to an extent, where they probably become harmless. This scheme will first be explained for a simple model to clarify the idea. However, very precise three dimensional computations using realistic parameters are presented, corroborating the results of the simple model. Y1 - 2010 U6 - https://doi.org/10.1002/er.1662 SN - 0363-907X VL - 34 IS - 3 SP - 293 EP - 301 PB - Wiley CY - London ER - TY - JOUR A1 - Grottke, O. A1 - Braunschweig, T. A1 - Philippen, B. A1 - Gatzweiler, Karl-Heinz A1 - Gronloh, N. A1 - Staat, Manfred A1 - Rossaint, R. A1 - Tolba, R. T1 - A New Model for Blunt Liver Injuries in the Swine JF - European Surgical Research. 44 (2010), H. 2 Y1 - 2010 SN - 1421-9921 SP - 65 EP - 73 ER - TY - JOUR A1 - Niemüller, Tim A1 - Ferrein, Alexander A1 - Lakemeyer, Gerhard T1 - A Lua-based behavior engine for controlling the humanoid robot Nao JF - RoboCup 2009: Robot Soccer World Cup XIII Y1 - 2010 U6 - https://doi.org/10.1007/978-3-642-11876-0_21 N1 - Part of the book series: Lecture Notes in Computer Science ((LNAI,volume 5949)) N1 - 13th RoboCup International Symposium, Graz, Austria, June/July, 2009 SP - 240 EP - 251 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Rens, Gavin A1 - Varzinczak, Ivan A1 - Meyer, Thomas A1 - Ferrein, Alexander T1 - A Logic for Reasoning about Actions and Explicit Observations JF - AI 2010: Advances in Artificial Intelligence 23rd Australasian Joint Conference, Adelaide, Australia, December 7-10, 2010. Proceedings Y1 - 2010 U6 - https://doi.org/10.1007/978-3-642-17432-2_40 N1 - Lecture Notes in Computer Science ; 6464 SP - 395 EP - 404 PB - Springer CY - Berlin ER - TY - JOUR A1 - Nguyen, N.-H. A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred T1 - A hyperelastic model of biological tissue materials in tubular organs Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 12 ER - TY - JOUR A1 - Gerhards, Michael A1 - Belloum, Adam A1 - Berretz, Frank A1 - Sander, Volker A1 - Skorupa, Sascha T1 - A history-tracing XML-based provenance framework for workflows JF - The 5th Workshop on Workflows in Support of Large-Scale Science N2 - The importance of validating and reproducing the outcome of computational processes is fundamental to many application domains. Assuring the provenance of workflows will likely become even more important with respect to the incorporation of human tasks to standard workflows by emerging standards such as WS-HumanTask. This paper addresses this trend by an actor-based workflow approach that actively support provenance. It proposes a framework to track and store provenance information automatically that applies for various workflow management systems. In particular, the introduced provenance framework supports the documentation of workflows in a legally binding way. The authors therefore use the concept of layered XML documents, i.e. history-tracing XML. Furthermore, the proposed provenance framework enables the executors (actors) of a particular workflow task to attest their operations and the associated results by integrating digital XML signatures. KW - workflow KW - provenance KW - framework KW - containers KW - humans KW - synchronization KW - libraries KW - history KW - concrete KW - XML Y1 - 2010 SN - 978-1-4244-8989-3 U6 - https://doi.org/10.1109/WORKS.2010.5671873 N1 - The 5th Workshop on Workflows in Support of Large-Scale Science, 14 Nov. 2010, New Orleans, USA PB - IEEE CY - New York ER - TY - JOUR A1 - Bernecker, Andreas T1 - A European Private Company: Is Europe’s single legal form for SMEs close to approval? JF - Research Briefing N2 - This Research Briefing, issued in July 2010, concluded that: - Small and medium-sized enterprises (SMEs) in Europe have long called for a matching legal form valid across the EU (similar to that of the European company (SE) for large firms) - The main benefits would be the availability of uniform Europe-wide company structures, significant cost reductions for businesses and further integration of the internal market - Given the differing national views regarding the concrete features of the new legal form there is currently no sign of an agreement being reached at the European level in the short term; however, it is possible that progress will be made in negotiations during the year - The key issues being discussed in depth are company formation, transnationality and employee participation rights in the new European private company (SPE). Y1 - 2010 SN - 2193-5955 PB - Deutsche Bank Research CY - Frankfurt a. M. ER - TY - JOUR A1 - Jansen, Sebastian A1 - Behbahani, Mehdi A1 - Laumen, Marco A1 - Kaufmann, Tim A1 - Hormes, Marcus A1 - Schmitz-Rode, Thomas A1 - Behr, Marek A1 - Steinseifer, Ulrich T1 - 3D Stereo-PIV Validation for CFD-Simulation of Steady Flow through the Human Aorta using Rapid-Prototyping techniques Y1 - 2010 N1 - abstract ; IV International Symposium on Modelling of Physiological Flows, Sardinia, Italy, June 02-05, 2010 ; MPF2010 ER -