TY - JOUR A1 - Heinzel, Alexander A1 - Schäfer, Ralf A1 - Müller, Hans-Wilhelm A1 - Schieffer, Andre A1 - Ingenhag, Ariane A1 - Eickhoff, Simon B. A1 - Northoff, Georg A1 - Franz, Matthias A1 - Hautzel, Hubertus T1 - Increased Activation of the Supragenual Anterior Cingulate Cortex during Visual Emotional Processing in Male Subjects with High Degrees of Alexithymia: An Event-Related fMRI Study JF - Psychotherapy and Psychosomatics N2 - Background: One of the most prominent neurobiological models of alexithymia assumes an altered function of the anterior cingulate cortex (ACC) as the crucial neural correlate of alexithymia. So far functional imaging studies have yielded inconclusive results. Therefore, we tested this hypothesis in healthy alexithymics and nonalexithymics in an event-related fMRI study. Methods: Thirty high- and 30 low-alexithymic right-handed male subjects (selected by the 20-item Toronto Alexithymia Scale, TAS-20) were investigated with event-related fMRI using a picture viewing paradigm. The stimuli consisted of happy, fearful and neutral facial expressions (Ekman-Friesen) as well as positive, negative and neutral pictures from the International Affective Picture System. Results: Contrasting the high-alexithymic with the low-alexithymic group we observed increased activation of the supragenual ACC for different emotional valences as well as for different emotional stimuli. Moreover, there was a positive correlation of the ACC with the individual TAS-20 scores but no correlations with the individual Beck Depression Inventory scores. Additionally, there was no difference in activity of the amygdala. Conclusions: We demonstrated that the supragenual ACC is constantly activated more strongly in alexithymic subjects and that this activation is related to the symptoms of alexithymia and not to associated symptoms such as depression. Therefore, our findings support the hypothesis of an altered function of the ACC in alexithymia. Y1 - 2010 U6 - https://doi.org/10.1159/000320121 SN - 0033-3190 VL - 79 IS - 6 SP - 363 EP - 370 PB - Karger CY - Basel ER - TY - JOUR A1 - Heinzel, Alexander A1 - Schäfer, Ralf A1 - Müller, Hans-Wilhelm A1 - Schieffer, Andre A1 - Ingenhag, Ariane A1 - Northoff, Georg A1 - Franz, Matthias A1 - Hautzel, Hubertus T1 - Differential modulation of valence and arousal in high-alexithymic and low-alexithymic individuals JF - Neuroreport N2 - High-alexithymic individuals are characterized by an impaired ability to identify and communicate emotions whereas low-alexithymic individuals have a wide-ranging ability to deal with emotions. This study examined the hypothesis that valence and arousal modifications of emotional stimuli differentially modulate cortical regions in high-alexithymic and low-alexithymic individuals. To this end, 28 high-alexithymic and 25 low-alexithymic individuals were investigated with event-related fMRI using visual emotional stimuli. We found differential neural activations in the dorsal anterior cingulate, the insula and the amygdala. We suggest that these differences may account for the impaired ability of high-alexithymic individuals to appropriately handle emotional stimuli. Y1 - 2010 U6 - https://doi.org/10.1097/WNR.0b013e32833f38e0 SN - 1473-558X VL - 21 IS - 15 SP - 998 EP - 1002 PB - Lippincott Williams & Wilkins CY - London ER - TY - JOUR A1 - Beer, S. A1 - Streun, M. A1 - Hombach, T. A1 - Buehler, J. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants JF - Physics in Medicine and Biology N2 - Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements. Y1 - 2010 U6 - https://doi.org/10.1088/0031-9155/55/3/006 SN - 1361-6560 VL - 55 IS - 3 SP - 635 EP - 646 PB - IOP CY - Bristol ER - TY - JOUR A1 - Herzog, Hans A1 - Pietrzyk, Uwe A1 - Shah, N. Jon A1 - Ziemons, Karl T1 - The current state, challenges and perspectives of MR-PET JF - Neuroimage N2 - Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization. Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum Jülich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27–28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop. Y1 - 2010 U6 - https://doi.org/10.1016/j.neuroimage.2009.10.036 SN - 1053-8119 VL - 49 IS - 3 SP - 2072 EP - 2082 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jansen, Sebastian A1 - Behbahani, Mehdi A1 - Laumen, Marco A1 - Kaufmann, Tim A1 - Hormes, Marcus A1 - Schmitz-Rode, Thomas A1 - Behr, Marek A1 - Steinseifer, Ulrich T1 - 3D Stereo-PIV Validation for CFD-Simulation of Steady Flow through the Human Aorta using Rapid-Prototyping techniques Y1 - 2010 N1 - abstract ; IV International Symposium on Modelling of Physiological Flows, Sardinia, Italy, June 02-05, 2010 ; MPF2010 ER - TY - BOOK A1 - Schelthoff, Christof T1 - Mathematik im ingenieurwissenschaftlichen Bachelorstudium / 4., überarb. Aufl. Y1 - 2010 SN - 978-3-8322-9288-1 PB - Shaker CY - Aachen ER - TY - BOOK A1 - Schelthoff, Christof T1 - Mathematik im ingenieurwissenschaftlichen Bachelorstudium : Lösung der Übungs- und Klausuraufgaben Y1 - 2010 SN - 978-3-8322-9502-8 PB - Shaker CY - Aachen ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Nagel, Edgar A1 - Vilser, Walthard A1 - Seidova, Seid-Fatima A1 - Lanzl, Ines T1 - Microstructural alterations of retinal arterial blood column along the vessel axis in systemic hypertension JF - Investigative Ophthalmology & Visual Science, IOVS N2 - Purpose: Image analysis by the retinal vessel analyzer (RVA) observes retinal vessels in their dynamic state online noninvasively along a chosen vessel segment. It has been found that high-frequency diameter changes in the retinal artery blood column along the vessel increase significantly in anamnestically healthy volunteers with increasing age and in patients with glaucoma during vascular dilation. This study was undertaken to investigate whether longitudinal sections of the retinal artery blood column are altered in systemic hypertension. Methods: Retinal arteries of 15 untreated patients with essential arterial hypertension (age, 50.9 ± 11.9 years) and of 15 age-matched anamnestically healthy volunteers were examined by RVA. After baseline assessment, a monochromatic luminance flicker (530–600 nm; 12.5 Hz; 20 s) was applied to evoke retinal vasodilation. Differences in amplitude and frequency of spatial artery blood column diameter change along segments (longitudinal arterial profiles) of 1 mm in length were measured and analyzed using Fourier transformation. Results: In the control group, average reduced power spectra (ARPS) of longitudinal arterial profiles did not differ when arteries changed from constriction to dilation. In the systemic hypertension group, ARPS during constriction, baseline, and restoration were identical and differed from ARPS during dilation (P < 0.05). Longitudinal arterial profiles in both groups showed significant dissimilitude at baseline and restoration (P < 0.05). Conclusions: The retinal artery blood column demonstrates microstructural alterations in systemic hypertension and is less irregular along the vessel axis during vessel dilation. These microstructural changes may be an indication of alterations in vessel wall rigidity, vascular endothelial function, and smooth muscle cells in this disease, leading to impaired perfusion and regulation. Y1 - 2010 U6 - https://doi.org/10.1167/iovs.09-3649 SN - 0146-0404 VL - 51 IS - 4 SP - 2165 EP - 2172 PB - ARVO CY - Rockville, Md. ER - TY - JOUR A1 - Lanzl, Ines M. A1 - Seidova, Seid-Fatima A1 - Erben, A. A1 - Thürmel, K. A1 - Kotliar, Konstantin T1 - Diffuse stromale Hornhauttrübungen und Veränderungen der Hände JF - Der Ophthalmologe N2 - Bilaterale stromale Hornhauttrübungen sind für den Augenarzt eine differenzialdiagnostische Herausforderung. Im folgenden Beitrag werden 2 Patieninnen (30 und 36 Jahre) mit unterschiedlich stark ausgeprägter stromaler diffuser Hornhauttrübung vorgestellt. Patientin 1 war kleinwüchsig (114 cm) und Patientin 2 normal groß (172 cm). Beide Patientinnen wiesen veränderte Gelenkstrukturen an Hand und Fußgelenken sowie diffuse stromale Hornhauttrübungen auf. Des Weiteren lagen eine Mitral- und Aorteninsuffizienz (Patientin 1) bzw. eine Aorteninsuffizienz (Patientin 2) vor. Die stromalen diffusen Hornhauttrübungen ließen im Zusammenhang mit den Gelenkveränderungen ein Scheie-Syndrom vermuten. Therapeutisch ist bei Patienten mit Visusminderung eine (lamelläre) Keratoplastik sinnvoll. Y1 - 2010 U6 - https://doi.org/10.1007/s00347-009-2066-2 SN - 1433-0423 VL - 107 IS - 4 SP - 363 EP - 365 PB - Springer CY - Berlin ER - TY - JOUR A1 - Wiescher, A. A1 - Kotliar, Konstantin A1 - Neuhann, T. A1 - Lanzl, Ines M. T1 - Rasch progrediente Visusminderung beider Augen bei einem jungen Patienten JF - Der Ophthalmologe N2 - Ein 34-jähriger männlicher Patient stellte sich zur Abklärung einer seit dem 9. Lebensjahr bestehenden und im letzten Jahr rasch progredienten Visusminderung beider Augen bei uns vor. Er beschrieb eine subjektiv zunehmende, im Spiegel für ihn selbst sichtbare, weißliche Trübung in der Pupille beidseits und eine starke Blendempfindlichkeit. Nebenbefundlich gab er rezidivierende Konjunktivitiden und morgens verklebte Lider an. Eine Allergie auf Gräserpollen und eine Unverträglichkeit auf Alkohol sowie mehrere Lebensmittel seien ebenfalls bekannt. Zusätzlich leidet der Patient an stark ausgeprägtem atopischem Ekzem. Dieses wurde nie systemisch, sondern nur bei Bedarf mit kortisonhaltiger Salbe therapiert. Y1 - 2010 U6 - https://doi.org/10.1007/s00347-007-1586-x SN - 1433-0423 VL - 105 IS - 4 SP - 389 EP - 392 PB - Springer CY - Berlin ER - TY - JOUR A1 - Pressler, Axel A1 - Esefeld, Katrin A1 - Scherr, Johannes A1 - Ali, Mohammad A1 - Hanssen, Henner A1 - Kotliar, Konstantin A1 - Lanzl, Ines A1 - Halle, Martin A1 - Kaemmerer, Harald A1 - Schmidt-Trucksäss, Arno A1 - Hager, Alfred T1 - Structural alterations of retinal arterioles in adults late after repair of aortic isthmic coarctation JF - The American Journal of Cardiology N2 - Patients after coarctation repair still have an increased risk of cardiovascular or cerebrovascular events. This has been explained by the persisting hypertension and alterations in the peripheral vessels. However, involvement of the central vessels such as the retinal arteries is virtually unknown. A total of 34 patients after coarctation repair (22 men and 12 women; 23 to 58 years old, age range 0 to 32 years at surgical repair) and 34 nonhypertensive controls underwent structural and functional retinal vessel analysis. Using structural analysis, the vessel diameters were measured. Using functional analysis, the endothelium-dependent vessel dilation in response to flicker light stimulation was assessed. In the patients after coarctation repair, the retinal arteriolar diameter was significantly reduced compared to that of the controls (median 182 μm, first to third quartile 171 to 197; vs 197 μm, first to third quartile 193 to 206; p <0.001). These findings were independent of the peripheral blood pressure and age at intervention. No differences were found for venules. The functional analysis findings were not different between the patients and controls (maximum dilation 3.5%, first to third quartile 2.1% to 4.5% vs 3.6%, first to third quartile 2.2% to 4.3%; p = 0.81), indicating preserved autoregulative mechanisms. In conclusion, the retinal artery diameter is reduced in patients after coarctation repair, independent of their current blood pressure level and age at intervention. As a structural marker of chronic vessel damage associated with past, current, or future hypertension, retinal arteriolar narrowing has been linked to stroke incidence. These results indicate an involvement of cerebral microcirculation in aortic coarctation, despite timely repair, and might contribute to explain the increased rate of cerebrovascular events in such patients. Y1 - 2010 U6 - https://doi.org/10.1016/j.amjcard.2009.10.070 SN - 0002-9149 VL - 105 IS - 5 SP - 740 EP - 744 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Garhofer, Gerhard A1 - Bek, Toke A1 - Boehm, Andreas G. A1 - Gherghel, Doina A1 - Grundwald, Juan A1 - Jeppesen, Peter A1 - Kergoat, Hélène A1 - Kotliar, Konstantin A1 - Lanzl, Ines A1 - Lovasik, John V. A1 - Nagel, Edgar A1 - Vilser, Walthard A1 - Orgul, Selim A1 - Schmetterer, Leopold T1 - Use of the retinal vessel analyzer in ocular blood flow research JF - Acta Ophthalmol N2 - The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed. Y1 - 2010 U6 - https://doi.org/10.1111/j.1755-3768.2009.01587.x SN - 1755-3768 VL - 88 IS - 7 SP - 717 EP - 722 PB - Wiley-Blackwell CY - Oxford ER - TY - CHAP A1 - Artmann, Gerhard A1 - Stadler, Andreas M. A1 - Embs, Jan P. A1 - Zaccai, Giuseppe A1 - Büldt, Georg A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül T1 - The crucial role of water in a phase transition of hemoglobin at body temperature : [abstract] N2 - The observation of a temperature transition of hemoglobin occurring at a critical temperature close to body temperature KW - Hämoglobin KW - Erythrozyt KW - Körpertemperatur Y1 - 2010 ER - TY - JOUR A1 - Kurz, R. A1 - Linder, Peter A1 - Trzewik, Jürgen A1 - Rüffer, M. A1 - Artmann, Gerhard A1 - Digel, Ilya A1 - Rothermel, A. A1 - Robitzki, A. A1 - Temiz Artmann, Aysegül T1 - Contractile tension and beating rates of self-exciting monolayers and 3D-tissue constructs of neonatal rat cardiomyocytes JF - Medical and Biological Engineering and Computing N2 - The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocytes. Cells were grown either within flexible, circular collagen gels or as monolayer on top of respective 1-mum thin silicone membranes. Membrane and cells were bulged outwards by air pressure. This biaxial strain distribution is rather similar the beating, blood-filled heart. The setup allowed presetting the mechanical residual stress level externally by adjusting the centre deflection, thus, mimicking hypertension in vitro. Tension was measured as oscillating differential pressure change between chamber and environment. A 0.5-mm thick collagen-cardiac myocyte tissue construct induced after 2 days of culturing (initial cell density 2 x 10(4) cells/ml), a mechanical tension of 1.62 +/- 0.17 microN/mm(2). Mechanical load is an important growth regulator in the developing heart, and the orientation and alignment of cardiomyocytes is stress sensitive. Therefore, it was necessary to develop the CellDrum technology with its biaxial stress-strain distribution and defined mechanical boundary conditions. Cells were exposed to strain in two directions, radially and circumferentially, which is similar to biaxial loading in real heart tissues. Thus, from a biomechanical point of view, the system is preferable to previous setups based on uniaxial stretching. Y1 - 2010 U6 - https://doi.org/10.1007/s11517-009-0552-y SN - 1741-0444 VL - 48 IS - 1 SP - 59 EP - 65 PB - Springer Nature CY - Cham ER - TY - CHAP A1 - Digel, Ilya A1 - Leimena, W. A1 - Dachwald, Bernd A1 - Linder, Peter A1 - Porst, Dariusz A1 - Kayser, Peter A1 - Funke, O. A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard T1 - In-situ biological decontamination of an ice melting probe : [abstract] N2 - The objective of our study was to investigate the efficacy of different in-situ decontamination protocols in the conditions of thermo-mechanical ice-melting. KW - Sonde KW - Dekontamination KW - Wasserstoffperoxid KW - Natriumhypochlorit Y1 - 2010 ER - TY - BOOK A1 - Laack, Walter van T1 - Schnittstelle Tod: Aufbruch zu neuem Leben? Y1 - 2010 SN - 978-3-936624-10-6 N1 - Tagungsbeiträge des 1. Europäischen Seminars in Aachen zum Thema Nahtoderfahrungen mit dem Titel: "Schnittstelle Tod", am 7. November 2009 / [Hrsg.: Walter van Laack] PB - Books on Demand CY - Norderstedt ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Peper, Andreas A1 - Bierbaum, Stefanie A1 - Albracht, Kirsten T1 - Plasticity of human Achilles tendon mechanical and morphological properties in response to cyclic strain JF - Journal of Biomechanics N2 - The purpose of the current study in combination with our previous published data (Arampatzis et al., 2007) was to examine the effects of a controlled modulation of strain magnitude and strain frequency applied to the Achilles tendon on the plasticity of tendon mechanical and morphological properties. Eleven male adults (23.9±2.2 yr) participated in the study. The participants exercised one leg at low magnitude tendon strain (2.97±0.47%), and the other leg at high tendon strain magnitude (4.72±1.08%) of similar frequency (0.5 Hz, 1 s loading, 1 s relaxation) and exercise volume (integral of the plantar flexion moment over time) for 14 weeks, 4 days per week, 5 sets per session. The exercise volume was similar to the intervention of our earlier study (0.17 Hz frequency; 3 s loading, 3 s relaxation) allowing a direct comparison of the results. Before and after the intervention ankle joint moment has been measured by a dynamometer, tendon–aponeurosis elongation by ultrasound and cross-sectional area of the Achilles tendon by magnet resonance images (MRI). We found a decrease in strain at a given tendon force, an increase in tendon–aponeurosis stiffness and tendon elastic modulus of the Achilles tendon only in the leg exercised at high strain magnitude. The cross-sectional area (CSA) of the Achilles tendon did not show any statistically significant (P>0.05) differences to the pre-exercise values in both legs. The results indicate a superior improvement in tendon properties (stiffness, elastic modulus and CSA) at the low frequency (0.17 Hz) compared to the high strain frequency (0.5 Hz) protocol. These findings provide evidence that the strain magnitude applied to the Achilles tendon should exceed the value, which occurs during habitual activities to trigger adaptational effects and that higher tendon strain duration per contraction leads to superior tendon adaptational responses. Y1 - 2010 U6 - https://doi.org/10.1016/j.jbiomech.2010.08.014 SN - 0021-9290 VL - 43 IS - 16 SP - 3073 EP - 3079 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Aggeloussis, Nickos A1 - Giannakou, Erasmia A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios T1 - Reproducibility of fascicle length and pennation angle of gastrocnemius medialis in human gait in vivo JF - Gait and Posture N2 - The purpose of the current study was to examine the reproducibility of fascicle length and pennation angle of gastrocnemius medialis while human walking. To the best of our knowledge, this is the first study of the reproducibility of fascicle length and pennation angle of gastrocnemius medialis in vivo during human gait. Twelve males performed 10 gait trials on a treadmill, in 2 separate days. B-mode ultrasonography, with the ultrasound probe firmly adjusted in the transverse and frontal planes using a special cast, was used to measure the fascicle length and the pennation angle of the gastrocnemius medialis (GM). A Vicon 624 system with three cameras operating at 120 Hz was also used to record the ankle and knee joint angles. The results showed that measurements of fascicle length and pennation angle showed high reproducibility during the gait cycle, both within the same day and between different days. Moreover, the root mean square differences between the repeated waveforms of both variables were very small, compared with their ranges (fascicle length: RMS = ∼3 mm, range: 38–63 mm; pennation angle: RMS = ∼1.5°, range: 22–32°). However, their reproducibility was lower compared to the joint angles. It was found that representative data have to be derived by a wide number of gait trials (fascicle length ∼six trials, pennation angle more than 10 trials), to assure the reliability of the fascicle length and pennation angle in human gait. Y1 - 2010 U6 - https://doi.org/10.1016/j.gaitpost.2009.08.249 SN - 0966-6362 VL - 31 IS - 1 SP - 73 EP - 77 PB - Elsevier CY - Amsterdam ER - TY - RPRT A1 - Temiz Artmann, Aysegül T1 - Frühgeburtenrate mindern durch ein Prognoseverfahren für den vorzeitigen Blasensprung - PROMPT (Premature rupture of membranes prediction test) : Abschlussbericht ; Laufzeit des Vorhabens: 01.03.2007 - 31.12.2009 Y1 - 2010 U6 - https://doi.org/10.2314/GBV:644277858 N1 - Förderkennzeichen BMBF 1772X07 PB - Technische Informationsbibliothek u. Universitätsbibliothek CY - Aachen ER - TY - THES A1 - Albracht, Kirsten T1 - Influence of mechanical properties of the leg extensor muscletendon units on running economy Y1 - 2010 N1 - Cologne, German Sport Univ., Diss., 2010 PB - Deutsche Sporthochschule Köln CY - Köln ER - TY - JOUR A1 - Zhubanova, Azhar A. A1 - Aknazarov, S. K. A1 - Mansurov, Zulkhair A1 - Digel, Ilya A1 - Kozhalakova, A. A. A1 - Akimbekov, Nuraly S. A1 - O'Heras, Carlos A1 - Tazhibayeva, S. A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - Adsorption of bacterial Lipopolysaccharides and blood plasma proteins on modified carbonized materials N2 - Bacterial lipopolysaccharides (endotoxins) show strong biological effects at very low concentrations in human beings and many animals when entering the blood stream. These include affecting structure and function of organs and cells, changing metabolic functions, raising body temperature, triggering the coagulation cascade, modifying hemodynamics and causing septic shock. Because of this toxicity, the removal of even minute amounts is essential for safe parenteral administration of drugs and also for septic shock patients' care. The absence of a general method for endotoxin removal from liquid interfaces urgently requires finding new methods and materials to overcome this gap. Nanostructured carbonized plant parts is a promising material that showed good adsorption properties due to its vast pore network and high surface area. The aim of this study was comparative measurement of endotoxin- and blood proteins-related adsorption rate and adsorption capacity for different carboneous materials produced at different temperatures and under different surface modifications. As a main surface modificator, positively cbarged polymer, polyethileneimine (PEl) was used. Activated carbon materials showed good adsorption properties for LPS and some proteins used in the experiments. During the batch experiments, several techniques (dust removal, autoclaving) were used and optimized for improving the material's adsorption behavior. Also, with the results obtained it was possible to differentiate the materials according to their adsorption capacity and kinetic characteristics. Modification of the surface apparently has not affected hemoglobin binding to the adsorbent's surface. Obtained adsorption isotherms can be used as a powerful tool for designing of future column-based setups for blood purification from LPS, which is especially important for septic shock treatment. KW - Kohlenstofffaser KW - Lipopolysaccharide KW - nanostrukturierte carbonisierte Pflanzenteile KW - lipopolysaccharides KW - nanostructured carbonized plant parts Y1 - 2010 ER - TY - JOUR A1 - Akimbekov, Nuraly S. A1 - Zhubanova, A. A. A1 - Mansurov, Z. A. A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - Use of Carbonized Rise Shell for the local treatment of wounds JF - Eurasian ChemTech Journal N2 - On the model of musculocutaneous wound in rats, the effect of applicative sorption by carbonized rise shell (CRS) on the healing of festering wound was studied. It has been shown, that cytological changes end with rapid scar formation. The use of CRS at the period of severe purulent wound contributes to its favorable course, prevents the development of complications of the animals from sepsis. Y1 - 2010 U6 - https://doi.org/10.18321/ectj35 SN - 2522-4867 VL - 12 IS - 2 SP - 133 EP - 138 PB - Institute of Combustion Problems CY - Almaty ER - TY - CHAP A1 - Kurulgan Demirci, Eylem A1 - Linder, Peter A1 - Demirci, Taylan A1 - Gierkowski, Jessica R. A1 - Digel, Ilya A1 - Gossmann, Matthias A1 - Temiz Artmann, Aysegül T1 - rhAPC reduces the endothelial cell permeability via a decrease of cellular mechanical contractile tensions : [abstract] N2 - In this study, the CellDrum technology quanitfying cellular mechanical tension on a pico-scale was used to investigate the effect of LPS (lipopolysaccharide) on HAoEC (Human Aortic Endothelial Cell) tension. KW - Endothelzelle KW - Sepsis KW - kontraktile Spannung KW - rhAPC KW - contractile tension KW - rhAPC KW - celldrum technology Y1 - 2010 ER - TY - JOUR A1 - Horstmann, Marie-Therese A1 - Bialonski, Stephan A1 - Noenning, Nina A1 - Mai, Heinke A1 - Prusseit, Jens A1 - Wellmer, Jörg A1 - Hinrichs, Hermann A1 - Lehnertz, Klaus T1 - State dependent properties of epileptic brain networks: Comparative graph–theoretical analyses of simultaneously recorded EEG and MEG JF - Clinical Neurophysiology N2 - Objective To investigate whether functional brain networks of epilepsy patients treated with antiepileptic medication differ from networks of healthy controls even during the seizure-free interval. Methods We applied different rules to construct binary and weighted networks from EEG and MEG data recorded under a resting-state eyes-open and eyes-closed condition from 21 epilepsy patients and 23 healthy controls. The average shortest path length and the clustering coefficient served as global statistical network characteristics. Results Independent on the behavioral condition, epileptic brains exhibited a more regular functional network structure. Similarly, the eyes-closed condition was characterized by a more regular functional network structure in both groups. The amount of network reorganization due to behavioral state changes was similar in both groups. Consistent findings could be achieved for networks derived from EEG but hardly from MEG recordings, and network construction rules had a rather strong impact on our findings. Conclusions Despite the locality of the investigated processes epileptic brain networks differ in their global characteristics from non-epileptic brain networks. Further methodological developments are necessary to improve the characterization of disturbed and normal functional networks. Significance An increased regularity and a diminished modulation capability appear characteristic of epileptic brain networks. Y1 - 2010 U6 - https://doi.org/10.1016/j.clinph.2009.10.013 SN - 1388-2457 VL - 121 IS - 2 SP - 172 EP - 185 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Lehnertz, Klaus A1 - Bialonski, Stephan A1 - Horstmann, Marie-Therese A1 - Krug, Dieter A1 - Rothkegel, Alexander A1 - Staniek, Matthäus A1 - Wagner, Tobias T1 - Epilepsy T2 - Reviews of Nonlinear Dynamics and Complexity, Volume 2 Y1 - 2010 SN - 9783527628001 U6 - https://doi.org/10.1002/9783527628001.ch5 SP - 159 EP - 200 PB - Wiley-VCH ER - TY - JOUR A1 - Bialonski, Stephan A1 - Horstmann, Marie-Therese A1 - Lehnertz, Klaus T1 - From brain to earth and climate systems: Small-world interaction networks or not? JF - Chaos: An Interdisciplinary Journal of Nonlinear Science N2 - We consider recent reports on small-world topologies of interaction networks derived from the dynamics of spatially extended systems that are investigated in diverse scientific fields such as neurosciences, geophysics, or meteorology. With numerical simulations that mimic typical experimental situations, we have identified an important constraint when characterizing such networks: indications of a small-world topology can be expected solely due to the spatial sampling of the system along with the commonly used time series analysis based approaches to network characterization. Y1 - 2010 U6 - https://doi.org/10.1063/1.3360561 SN - 1089-7682 VL - 20 IS - 1 PB - AIP Publishing CY - Melville, NY ER - TY - JOUR A1 - Grajewski, Matthias A1 - Köster, Michael A1 - Turek, Stefam T1 - Numerical analysis and implementational aspects of a new multilevel grid deformation method JF - Applied Numerical Mathematics N2 - Recently, we introduced and mathematically analysed a new method for grid deformation (Grajewski et al., 2009) [15] we call basic deformation method (BDM) here. It generalises the method proposed by Liao et al. (Bochev et al., 1996; Cai et al., 2004; Liao and Anderson, 1992) [4], [6], [20]. In this article, we employ the BDM as core of a new multilevel deformation method (MDM) which leads to vast improvements regarding robustness, accuracy and speed. We achieve this by splitting up the deformation process in a sequence of easier subproblems and by exploiting grid hierarchy. Being of optimal asymptotic complexity, we experience speed-ups up to a factor of 15 in our test cases compared to the BDM. This gives our MDM the potential for tackling large grids and time-dependent problems, where possibly the grid must be dynamically deformed once per time step according to the user's needs. Moreover, we elaborate on implementational aspects, in particular efficient grid searching, which is a key ingredient of the BDM. Y1 - 2010 U6 - https://doi.org/10.1016/j.apnum.2010.03.017 SN - 0168-9274 VL - 60 IS - 8 SP - 767 EP - 781 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Riepl, Herbert Matthias A1 - Pettrak, Jürgen A1 - Faulstich, Martin A1 - Herrmann, Wolfgang Anton T1 - Self metathesis of fatty alcohols and amines to provide monomers for polyester and polyamide products JF - Macromolecular Symposia N2 - Self metathesis of oleochemicals offers a variety of bifunctional compounds, that can be used as monomer for polymer production. Many precursors are in huge scales available, like oleic acid ester (biodiesel), oleyl alcohol (tensides), oleyl amines (tensides, lubricants). We show several ways to produce and separate and purify C18-α,ω-bifunctional compounds, using Grubbs 2nd Generation catalysts, starting from technical grade educts. KW - fatty acid KW - metathesis KW - polyamide KW - polyester KW - renewable resources Y1 - 2010 U6 - https://doi.org/10.1002/masy.200900041 SN - 1521-3900 (eISSN) SN - 0258-0322 SN - 1022-1360 N1 - Special Issue: "Olefin Metathesis" VL - 293 IS - 1 SP - 39 EP - 42 PB - Wiley-VCH CY - Weinheim ER - TY - THES A1 - Pettrak, Jürgen T1 - Nutzung nachwachsender Rohstoffe bei der Herstellung thermoplastischer Elastomere aus Folgeprodukten der Olefinmetathese N2 - Metathese von Ölsäure und Derivaten ist ein interessanter Weg für die Synthese bifunktioneller Verbindungen aus nachwachsenden Rohstoffen. Verwendet wurden Ru-Katalysatoren der zweiten Generation, welche eine hohe Toleranz gegenüber funktionellen Gruppen und Verunreinigungen aufweisen. Trotz des Einsatzes technischer Edukte waren Umsetzungen mit niedrigen Katalysatormengen (0.001 – 0.01 mol-%) möglich, mit Ausbeuten entsprechend der Literatur. Kreuzmetathesen ermöglichten variable Kettenlängen und Funktionalitäten der Monomere, die Produktgewinnung ist jedoch aufwändig. Selbstmetathese lieferte C18-bifunktionelle Verbindungen, welche einfach durch Destillation oder Kristallisation isoliert werden können. Neben der katalystischen Umsetzung wurde auch die Produktgewinnung untersucht und für ausgewählte Produkte auch im größeren Maßstab durchgeführt. Y1 - 2010 PB - Technische Universität München CY - München ER - TY - GEN A1 - Digel, Ilya T1 - In-situ biological decontamination of an ice melting probe Y1 - 2010 N1 - 38th COSPAR Scientific Assembly. Held 18-15 July 2010, in Bremen, Germany Abstract unter https://www.cospar-assembly.org/abstractcd/OLD/COSPAR-10/abstracts/data/pdf/abstracts/F36-0013-10.pdf ER - TY - JOUR A1 - Kozhalakova, A. A. A1 - Zhubanova, Azhar A. A1 - Mansurov, Z. A. A1 - Digel, Ilya A1 - Tazhibayeva, S. M. A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - Adsorption of bacterial lipopolysaccharides on carbonized rice shell JF - Science of Central Asia Y1 - 2010 SP - 50 EP - 54 ER - TY - CHAP A1 - Abel, Thomas A1 - Bonin, Dominik A1 - Albracht, Kirsten A1 - Zeller, Sebastian A1 - Brüggemann, Gert-Peter A1 - Burkett, Brendan A1 - Strüder, Heiko K. T1 - Kinematic profile of the elite handcyclist T2 - 28th International Conference on Biomechanics in Sports, Marquette, Michigan, USA, July 19 – 23, 2010 Y1 - 2017 SN - 1999-4168 SP - 140 EP - 141 ER - TY - CHAP A1 - Beging, Stefan A1 - Poghossian, Arshak A1 - Mlynek, D. A1 - Hataihimakul, S. A1 - Pedraza, A. A1 - Dhawan, S. A1 - Laube, N. A1 - Kleinen, Lisa A1 - Baldsiefen, Gerhard A1 - Busch, Heinrich von A1 - Schöning, Michael Josef T1 - Ion-selective sensors for the determination of the risk of urinary stone formation T2 - Micro- and Nanosystems in biochemical diagnosis : Principles and applications Y1 - 2010 SP - 74 EP - 80 CY - Warsaw ER - TY - JOUR A1 - Leimena, W. A1 - Artmann, Gerhard A1 - Dachwald, Bernd A1 - Temiz Artmann, Aysegül A1 - Gossmann, Matthias A1 - Digel, Ilya T1 - Feasibility of an in-situ microbial decontamination of an ice-melting probe JF - Eurasian Chemico-Technological Journal N2 - Autonomous robotic systems for penetrating thick ice shells with simultaneous collecting of scientific data are very promising devices in both terrestrial (glacier, climate research) and extra-terrestrial applications. Technical challenges in development of such systems are numerous and include 3D-navigation, an appropriate energy source, motion control, etc. Not less important is the problem of forward contamination of the pristine glacial environments with microorganisms and biomolecules from the surface of the probe. This study was devoted to establishing a laboratory model for microbial contamination of a newly constructed ice-melting probe called IceMole and to analyse the viability and amount of the contaminating microorganisms as a function of distance. The used bacterial strains were Bacillus subtilis (ATCC 6051) and Escherichia coli (ATCC 11775). The main objective was development of an efficient and reliable in-situ decontamination method of the melting probe. Therefore, several chemical substances were tested in respect of their efficacy to eliminate bacteria on the surface of the melting probe at low temperature (0 - 5 °C) and at continuous dilution by melted water. Our study has shown that at least 99.9% decontamination of the IceMole can be successfully achieved by the injection of 30% (v/v) hydrogen peroxide and 3% (v/v) sodium hypochlorite into the drilling site. We were able to reproduce this result in both time-dependent and depth-dependent experiments. The sufficient amount of 30% (v/v) H₂O₂ or 3% (v/v) NaClO has been found to be approximately 18 L per cm² of the probe’s surface. Y1 - 2010 SN - 1562-3920 U6 - https://doi.org/10.18321/ectj37 VL - 12 IS - 2 SP - 145 EP - 150 PB - Institute of Combustion Problems CY - Almaty ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Kaneko, Kazumi A1 - Matsuo, Akira A1 - Wagner, Torsten A1 - Kanoh, Shin`ichiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Miniaturized chemical imaging sensor system using an OLED display panel JF - Procedia Engineering N2 - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the currentvoltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated. Y1 - 2010 U6 - https://doi.org/10.1016/j.proeng.2010.09.160 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 516 EP - 519 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Wagner, Holger A1 - Schöning, Michael Josef T1 - Automatisiertes „wafer level“-Testsystem zur Charakterisierung von siliziumbasierten Chemo- und Biosensoren JF - Tagungsband: Sensoren und Messsysteme 2010 N2 - Es wurde ein automatisiertes, computerunterstütztes Testsystem für die Funktionsprüfung und Charakterisierung von (bio-)chemischen Sensoren auf Waferebene entwickelt und in einen konventionellen Spitzenmessplatz integriert. Das System ermöglicht die Charakterisierung und Identifizierung „funktionstauglicher“ Sensoren bereits auf Waferebene zwischen den einzelnen Herstellungsschritten, wodurch weitere, bisher übliche Verarbeitungsschritte wie das Fixieren, Bonden und Verkapseln für die defekten oder nicht funktionstauglichen Sensorstrukturen entfällt. Außerdem bietet eine speziell entworfene miniaturisierte Durchflussmesszelle die Möglichkeit, bereits auf Waferlevel die Sensitivität, Drift, Hysterese und Ansprechzeit der (bio-)chemischen Sensoren zu charakterisieren. Das System wurde exemplarisch mit kapazitiven, pH-sensitiven EIS- (Elektrolyt-Isolator-Silizium) Strukturen und ISFET- (ionensensitiver Feldeffekttransistor) Strukturen mit verschiedenen Geometrien und Gate-Layouts getestet. Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Sensoren und Messsysteme 2010 - 15. ITG/GMA-Fachtagung, 18.05.2010 - 19.05.2010 in Nürnberg SP - 89 EP - 92 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Rysstad, Gunnar A1 - Berger, Jörg A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry JF - Procedia Engineering N2 - A calorimetric gas sensor is presented for the monitoring of gas-phase H2O2 at elevated temperature during sterilization processes in aseptic food industry. The sensor consists of two temperature-sensitive thin-film resistances built up on a polyimide foil with a thickness of 25 μm, which are passivated with a layer of SU-8 photo resist and catalytically activated with manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilizes the elevated temperature of an evaporated H2O2 aerosol. In an experimental set-up, the sensor has shown a sensitivity of 4.78 °C/(%v/v) in a H2O2 concentration range of 0 to 10% v/v at an evaporation temperature of 240 ∘C. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied evaporation temperatures of the gas stream. The sensor characterization demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of sterilization processes. Y1 - 2010 U6 - https://doi.org/10.1016/j.proeng.2010.09.098 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 264 EP - 267 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Stütz, Evamaria A1 - Fleischer, Maximilian A1 - Schöning, Michael Josef T1 - Real-time detection of CO by eukaryotic cells JF - Procedia Engineering N2 - In this contribution, we focus on the detection of toxic gases with living eukaryotic cells. A cell-based gas sensor system, able to measure the effects of direct exposure of gases to cells in real-time, was set up. Impedance data as well as oxygen consumption of Chinese hamster lung fibroblast cells (V79) were analysed upon exposure to carbon monoxide (CO). The CO (diluted in wet synthetic air) affects the cell respiration as indicated by an attenuated respiration signal after the CO exposure as well as an instant increase of the capacitive part of the impedance signal during the gas exposure. Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 17 EP - 20 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kirchner, Patrick A1 - Spelthahn, Heiko A1 - Schöning, Michael Josef A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Friedrich, Peter A1 - Kolstad, Jens A1 - Berger, Jörg T1 - Realisierung eines Polyimid-basierten kalorimetrischen Gassensors zur Inline-Überwachung der H2O2-Konzentration in aseptischen Abfüllsystemen JF - Tagungsband: Sensoren und Messsysteme 2010 N2 - In aseptischen Abfüllsystemen wird Wasserstoffperoxid in der Gasphase aufgrund der stark oxidativen Wirkung zur Packstoffentkeimung eingesetzt. Dabei wird die Effizienz der Entkeimung im Wesentlichen von der vorliegenden H2O2-Konzentration im Packstoff bestimmt. Zur Inline-Überwachung der H2O2-Konzentration wurde ein kalorimetrischer Gassensor auf Basis einer flexiblen Polyimidfolie aus temperatursensitiven Dünnschicht-Widerständen und Mangan(IV)-oxid als katalytische Transducerschicht realisiert. Der Sensor weist ein lineares Ansprechverhalten mit einer Sensitivität von 7,15 °C/Vol.-% in einem H2O2-Konzentrationsbereich von 0 bis 8 Vol.-% auf. Weiterhin wurde zur Auslesung des Sensorsignals eine RFID-Elektronik, bestehend aus einem Sensor-Tag und einer Sende-/Empfangseinheit ausgelegt, sowie eine Abfolge des Messzyklus aufgestellt. Im weiteren Verlauf soll der kalorimetrische Gassensor mit der RFID-Elektronik gekoppelt und in eine Testverpackung zur Inline-Überwachung der H2O2-Konzentration in aseptischen Abfüllsystemen implementiert werden. Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Sensoren und Messsysteme 2010 - 15. ITG/GMA-Fachtagung, 18.05.2010 - 19.05.2010 in Nürnberg SP - 607 EP - 612 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schaffrath, Sophie A1 - Coppe, Thomas A1 - Rufi, Frederic A1 - Schöning, Michael Josef T1 - Development of an electrolyte-insulator-semiconductor (EIS) based capacitive heavy metal sensor for the detection of Pb2+ und Cd2+ ions JF - Physica status solidi (a) : applications and material science N2 - Chalcogenide glass materials as membranes for potentiometric sensors for chemical analysis in solutions have been studied since more than 20 years. In this work, an electrolyte–insulator–semiconductor structure was combined with chalcogenide glass membranes prepared by means of the pulsed laser deposition technique. Depending on the membrane composition a selectivity to different ions (Cd2+ and Pb2+) is achieved. The different sensor membranes have been physically characterised using microscopy, ellipsometry, profilometry, atomic force microscopy (AFM), scanning electron microscopy (SEM) and Rutherford backscattering spectrometry (RBS). The electrochemical behaviour has been investigated via capacitance/voltage (C/V) and constant capacitance (ConCap) measurements and results in a Cd2+ sensitivity of 23.1 ± 0.6 mV per decade in a linear range from 7 × 10−6 to 10−2 mol/l and 24.4 ± 0.5 mV per decade in a linear range from 5 × 10−6 to 10−2 mol/l for Pb2+, respectively. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983306 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 930 EP - 934 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Werner, Frederik A1 - Spelthahn, Heiko A1 - Schöning, Michael Josef A1 - Krumbe, Christoph A1 - Wagner, Torsten A1 - Yoshinobu, Tatsuo A1 - Keusgen, Michael T1 - Neue Ansteuerungselektronik für LAPS-basierte Biosensoren zur gleichzeitig ortsaufgelösten Messung der pH-Konzentration JF - Tagungsband: Sensoren und Messsysteme 2010 N2 - Ein lichtadressierbarer potentiometrischer Sensor (LAPS) kann die Konzentration eines oder mehrerer Analyten ortsaufgelöst auf der Sensoroberfläche nachweisen. Dazu wird mit einer modulierten Lichtquelle die Halbleiterstruktur des zu untersuchenden Bereiches angeregt und ein entsprechender Photostrom ausgelesen. Durch gleichzeitige Anregung mehrere Bereiche durch Lichtquellen mit unterschiedlichen Modulationsfrequenzen können diese auch zeitgleich ausgelesen werden. Mit der neuen, hier vorgestellten Ansteuerungselektronik integriert in einem "Field Programmable Gate Array" (FPGA) ist es möglich, mehrere Leuchtquellen gleichzeitig mit unterschiedlichen, während der Laufzeit festlegbaren Frequenzen, Phasen und Lichtintensitäten zu betreiben. Somit kann das Frequenzverhalten des Sensors untersucht und die Konzentration des Analyten über das Oberflächenpotential mit Hilfe von Strom/Spannungs-Kurven und Phase/Spannungs-Kurven bestimmt werden. Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Sensoren und Messsysteme 2010 - 15. ITG/GMA-Fachtagung, 18.05.2010 - 19.05.2010 in Nürnberg SP - 109 EP - 114 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Schnitzler, Thomas A1 - Biselli, Manfred A1 - Zang, Werner A1 - Wagner, Patrick T1 - Entwicklung eines modularen festkörperbasierten Sensorsystems für die Überwachung von Zellkulturfermentationen JF - Tagungsband: Sensoren und Messsysteme 2010 N2 - In diesem Beitrag werden Ergebnisse der Entwicklung eines modularen festkörperbasierten Sensorsystems für die Überwachung von Zellkulturfermentationen präsentiert. Zur Messung der Elektrolytleitfähigkeit wurde das Layout von Interdigitalelektroden angepasst, um in vergleichsweise gut leitenden Elektrolyten zu messen. Durch Quervernetzung von Glucose-Oxidase mit Glutaraldehyd und Immobilisierung auf einer Platinelektrode wurde ein amperometrischer Glucosesensor mit einem linearen Messbereich von bis zu 2 mM und einer Sensitivität von 168 nA/mM realisiert. Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Sensoren und Messsysteme 2010 - 15. ITG/GMA-Fachtagung, 18.05.2010 - 19.05.2010 in Nürnberg SP - 688 EP - 698 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Gerhards, Michael A1 - Belloum, Adam A1 - Berretz, Frank A1 - Sander, Volker A1 - Skorupa, Sascha T1 - A history-tracing XML-based provenance framework for workflows JF - The 5th Workshop on Workflows in Support of Large-Scale Science N2 - The importance of validating and reproducing the outcome of computational processes is fundamental to many application domains. Assuring the provenance of workflows will likely become even more important with respect to the incorporation of human tasks to standard workflows by emerging standards such as WS-HumanTask. This paper addresses this trend by an actor-based workflow approach that actively support provenance. It proposes a framework to track and store provenance information automatically that applies for various workflow management systems. In particular, the introduced provenance framework supports the documentation of workflows in a legally binding way. The authors therefore use the concept of layered XML documents, i.e. history-tracing XML. Furthermore, the proposed provenance framework enables the executors (actors) of a particular workflow task to attest their operations and the associated results by integrating digital XML signatures. KW - workflow KW - provenance KW - framework KW - containers KW - humans KW - synchronization KW - libraries KW - history KW - concrete KW - XML Y1 - 2010 SN - 978-1-4244-8989-3 U6 - https://doi.org/10.1109/WORKS.2010.5671873 N1 - The 5th Workshop on Workflows in Support of Large-Scale Science, 14 Nov. 2010, New Orleans, USA PB - IEEE CY - New York ER - TY - JOUR A1 - Wagner, Torsten A1 - Miyamoto, Ko-ichiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Novel combination of digital light processing (DLP) and light-addressable potentiometric sensors (LAPS) for flexible chemical imaging JF - Procedia Engineering N2 - Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach of read out in a light-addressable potentiometric sensor (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device which allows fast and flexible generation of light patterns. With the help of these light patterns the sensor surface of the LAPS device can be read out sequentially in a raster like scheme (scanning LAPS). The DLP approach has several advantages compared to conventional scanning LAPS set-ups, e.g., the spot size, the shape and the intensity of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of measurement. Y1 - 2010 U6 - https://doi.org/10.1016/j.proeng.2010.09.161 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 520 EP - 523 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Pedraza, A. M. A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Label-free DNA hybridization and denaturation detection by means of field-effect nanoplate SOI capacitors functionalized with gold nanoparticles JF - Procedia Engineering N2 - A new approach for a label-free electrical detection of DNA hybridization and denaturation using an array of individually addressable field-effect nanoplate SOI (silicon-on-insulator) capacitors functionalized with gold nanoparticles is presented. By using a constant-capacitance measuring setup in a differential mode, signal changes of ∼110 mV and ∼70 mV have been registered after the DNA hybridization and denaturation events, respectively. Y1 - 2010 U6 - https://doi.org/10.1016/j.proeng.2010.09.259 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 918 EP - 921 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Berretz, Frank A1 - Skorupa, Sascha A1 - Sander, Volker A1 - Belloum, Adam T1 - Towards an actor-driven workflow management system for grids JF - Proceedings of 2010 International Symposium on Collaborative Technologies and Systems N2 - Currently, most workflow management systems in Grid environments provide push-oriented job distribution strategies, where jobs are explicitly delegated to resources. In those scenarios the dedicated resources execute submitted jobs according to the request of a workflow engine or Grid wide scheduler. This approach has various limitations, particularly if human interactions should be integrated in workflow execution. To support human interactions with the benefit of enabling inter organizational computation and community approaches, this poster paper proposes the idea of a pull-based task distribution strategy. Here, heterogeneous resources, including human interaction, should actively select tasks for execution from a central repository. This leads to special demands regarding security issues like access control. In the established push-based job execution the resources are responsible for granting access to workflows and job initiators. In general this is done by access control lists, where users are explicitly mapped to local accounts according to their policies. In the pull-based approach the resources actively apply for job executions by sending requests to a central task repository. This means that every resource has to be able to authenticate against the repository to be authorized for task execution. In other words the authorization is relocated from the resources to the repository. The poster paper introduces current work regarding to the mentioned security aspects in the pull-based approach within the scope of the project “HiX4AGWS”. KW - scheduling KW - engines KW - resource management KW - grid computing KW - access control KW - distribution strategy KW - authorization KW - security KW - humans KW - workflow management software Y1 - 2010 SN - 978-1-4244-6619-1 U6 - https://doi.org/10.1109/CTS.2010.5478458 N1 - 2010 International Symposium on Collaborative Technologies and Systems, 17-21 May 2010, Chicago, IL, USA SP - 611 EP - 616 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - Wagner, Torsten A1 - Werner, Frederik A1 - Miyamoto, Ko-ichiro A1 - Ackermann, Hans-Josef A1 - Yoshinobu, Tatsuo A1 - Schöning, Michael Josef T1 - FPGA-based LAPS device for the flexible design of sensing sites on functional interfaces JF - Physica Status Solidi (A) N2 - The development of new interfaces for (bio-)chemical sensors requires comprehensive analyses and testing. The light-addressable potentiometric sensor (LAPS) can be used as a platform to investigate the sensitivity of a newly developed interface towards (bio-)chemical agents. LAPS measurements are spatially resolved by utilisation of focused light beams to define individual measurement spots. In this work, a new digitally modulated LAPS set-up based on an FPGA design will be introduced to increase the number of measurement spots, to shorten the measurement time and to improve the measurement accuracy. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983320 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 844 EP - 849 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Hirschfeld, Julian A. A1 - Lustfeld, Hans A1 - Reißel, Martin A1 - Steffen, Bernhard T1 - A novel scheme for precise diagnostics and effective stabilization of currents in a fuel cell stack JF - International Journal of Energy Research N2 - A novel scheme for detecting inhomogeneous internal currents in a fuel cell stack is presented. In this paper the scheme is investigated for the case that the flow field plates consist of graphite. Then plates of high conductivity, e.g. aluminium between the flow field plates together with small slits in these plates have three effects: (a) Whenever a local inhomogeneity of the electric current occurs at a particular cell in the stack, this will induce a surface current close to that cell perpendicular to the averaged current. This current can be detected. (b) The plates of high conductivity completely prevent the inhomogeneities from spreading to neighbouring cells. (c) Even at the particular cell the inhomogeneity is suppressed as far as possible. Thus this scheme leads to much better diagnostic possibilities and at the same time reduces electric instabilities to an extent, where they probably become harmless. This scheme will first be explained for a simple model to clarify the idea. However, very precise three dimensional computations using realistic parameters are presented, corroborating the results of the simple model. Y1 - 2010 U6 - https://doi.org/10.1002/er.1662 SN - 0363-907X VL - 34 IS - 3 SP - 293 EP - 301 PB - Wiley CY - London ER - TY - JOUR A1 - Hirschfeld, Julian A. A1 - Lustfeld, Hans A1 - Reißel, Martin A1 - Steffen, Bernhard T1 - Tomographic diagnostics of current distributions in a fuel cell stack JF - International Journal of Energy Research N2 - A novel tomographic scheme for analysing the state of any single membrane electrode assembly (MEA) in a stack is suggested. Plates of very high conductivity placed between every fuel cell and slitted in an appropriate manner cause surface currents at well-defined locations of the stack. We show that knowing these surface currents, information about anomalies of the currents in a MEA can be obtained using the methods of tomography. The results are mathematically not unique. However, when assuming plausible defect structures, one can exclude improbable deficiencies by applying a special form of simulated annealing. We present numerical calculations of typical examples demonstrating that the essential defects of the MEA in any single cell of the stack can be detected and their extent can be determined. Y1 - 2010 U6 - https://doi.org/10.1002/er.1634 SN - 0363-907X VL - 34 IS - 3 SP - 284 EP - 292 PB - Wiley CY - London ER - TY - JOUR A1 - Staat, Manfred A1 - Sponagel, Stefan A1 - Nguyen, Nhu Huynh T1 - Experiment and material model for soft tissue materials JF - Constitutive models for rubber VI N2 - Biomechanics studies biological soft tissue materials (growth, remodeling) in vivo. For this objective, the detailed information of material properties must be well defined to construct reliable constitutive models. In the paper, the bulge test is carried out with elastomers in order to develop a test method. Then, application of the test for soft tissue materials is straightforward due to the similarities between elastomers with soft tissue materials as proved in Holzapfel 2005, Ogden 2009. It means, after the preliminary experiments and parameter identification with rubber materials has been setup, experiments on soft tissue materials can be similarly carried out. Elastomers have a complex behavior which strongly depends on the largest previous load cycle. For simplicity we consider only the first loading. Y1 - 2010 SN - 9780429206597 (eBook) U6 - https://doi.org/10.1201/NOE0415563277-90 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Wenmackers, Sylvia A1 - Janssens, Stoffel D. A1 - Haenen, Ken A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Capacitive field-effect (bio-)chemical sensors based on nanocrystalline diamond films JF - MRS Online Proceedings Library N2 - Capacitive field-effect electrolyte-diamond-insulator-semiconductor (EDIS) structures with O-terminated nanocrystalline diamond (NCD) as sensitive gate material have been realized and investigated for the detection of pH, penicillin concentration, and layer-by-layer adsorption of polyelectrolytes. The surface oxidizing procedure of NCD thin films as well as the seeding and NCD growth process on a Si-SiO2 substrate have been improved to provide high pH-sensitive, non-porous thin films without damage of the underlying SiO2 layer and with a high coverage of O-terminated sites. The NCD surface topography, roughness, and coverage of the surface groups have been characterized by SEM, AFM and XPS methods. The EDIS sensors with O-terminated NCD film treated in oxidizing boiling mixture for 45 min show a pH sensitivity of about 50 mV/pH. The pH-sensitive properties of the NCD have been used to develop an EDIS-based penicillin biosensor with high sensitivity (65-70 mV/decade in the concentration range of 0.25-2.5 mM penicillin G) and low detection limit (5 μM). The results of label-free electrical detection of layer-by-layer adsorption of charged polyelectrolytes are presented, too. Y1 - 2010 SN - 1946-4274 VL - 1203 PB - MRS CY - Warrendale ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Vu, Khoi Duc A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - A primal-dual algorithm for shakedown analysis of elastic-plastic bounded linearly kinematic hardening bodies Y1 - 2010 N1 - 4th European Conference on Computational Mechanics (Solids, Structures and Coupled Problems in Engineering), ECCOMAS ECCM 2010, Paris, France, May 17 – 21, 2010 ER - TY - JOUR A1 - Nguyen, N.-H. A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred T1 - A hyperelastic model of biological tissue materials in tubular organs Y1 - 2010 N1 - 4th European Conference on Computational Mechanics (Solids, Structures and Coupled Problems in Engineering), ECCOMAS ECCM 2010, Paris, France, May 17 – 21, 2010 ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method Y1 - 2010 N1 - 4th European Conference on Computational Mechanics (Solids, Structures and Coupled Problems in Engineering), ECCOMAS ECCM 2010, Paris, France, May 17 – 21, 2010 ER - TY - JOUR A1 - Beging, Stefan A1 - Mlynek, Daniela A1 - Hataihimakul, Sudkanung A1 - Poghossian, Arshak A1 - Baldsiefen, Gerhard A1 - Busch, Heinz A1 - Laube, Norbert A1 - Kleinen, Lisa A1 - Schöning, Michael Josef T1 - Field-effect calcium sensor for the determination of the risk of urinary stone formation JF - Sensors and Actuators B: Chemical N2 - Urinary stone formation has been evolved to a widespread disease during the last years. The reason for the formation of urinary stones are little crystals, mostly composed of calcium oxalate, which are formed in human kidneys. The early diagnosis of the risk for urinary stone formation of patients can be determined by the “Bonn-Risk-Index” method based on the potentiometric detection of the Ca2+-ion concentration and an optical determination of the triggered crystallisation of calcium oxalate in unprocessed urine. In this work, miniaturised capacitive field-effect EMIS (electrolyte-membrane-insulator-semiconductor) sensors have been developed for the determination of the Ca2+-ion concentration in human native urine. The Ca2+-sensitive EMIS sensors have been systematically characterised by impedance spectroscopy, capacitance–voltage and constant–capacitance method in terms of sensitivity, signal stability and response time in both CaCl2 solutions and in native urine. The obtained results demonstrate the suitability of EMIS sensors for the measurement of the Ca2+-ion concentration in native urine of patients. Y1 - 2010 U6 - https://doi.org/10.1016/j.snb.2008.12.012 SN - 0925-4005 N1 - 22nd International Conference on Eurosensors: Dresden, Germany, 7-10 September 2008 VL - 144 IS - 2 SP - 374 EP - 379 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Reisert, Steffen A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schäfer, Daniel A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Schöning, Michael Josef T1 - Development of a handheld sensor system for the online measurement of hydrogen peroxide in aseptic filling systems JF - Physica Status Solidi (A) N2 - A handheld sensor system for the online measurement of hydrogen peroxide (H2O2) in aseptic sterilisation processes has been developed. It is based on a calorimetric-type gas sensor that consists of a differential set-up of two temperature sensors, of which one is catalytically activated and the second one is passivated and used as reference. The sensor principle relies in detecting a rise in temperature on the active sensor due to the exothermic reaction of H2O2 on the catalytic surface. To characterise the sensor system towards H2O2 sensitivity and other influencing factors, measurements have been carried out both at an experimental set-up and a manufacturer's sterilisation machine. Physical sensor characterisation was done by means of the optical microscopy. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983304 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 913 EP - 918 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Sugawara, Yuri A1 - Kanoh, Shin´ichiro A1 - Yoshinobu, Tatsuo A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Image correction method for the chemical imaging sensor JF - Sensors and Actuators B: Chemical N2 - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of chemical species. For the practical application of this sensor, artifacts in the chemical images due to defects of the semiconductor substrate and contamination of the sensing surface etc. have been a major problem. An image correction method was developed to eliminate the influence of nonuniformity of individual sensor plate. Y1 - 2010 U6 - https://doi.org/10.1016/j.snb.2008.10.069 SN - 0925-4005 N1 - 22nd International Conference on Eurosensors: Dresden, Germany, 7-10 September 2008 VL - 144 IS - 2 SP - 344 EP - 348 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Siqueira, José R. Jr. A1 - Oliveira, Osvaldo N. Jr. A1 - Moritz, Werner A1 - Schöning, Michael Josef T1 - Capacitive electrolyte-insulator-semiconductor structures functionalised with a polyelectrolyte/enzyme multilayer: New strategy for enhanced field-effect biosensing JF - Physica Status Solidi (A) N2 - A novel strategy for enhanced field-effect biosensing using capacitive electrolyte–insulator–semiconductor (EIS) structures functionalised with pH-responsive weak polyelectrolyte/enzyme or dendrimer/enzyme multilayers is presented. The feasibility of the proposed approach is exemplarily demonstrated by realising a penicillin biosensor based on a capacitive p-Si–SiO2 EIS structure functionalised with a poly(allylamine hydrochloride) (PAH)/penicillinase and a poly(amidoamine) dendrimer/penicillinase multilayer. The developed sensors response to changes in both the local pH value near the gate surface and the charge of macromolecules induced via enzymatic reaction, resulting in a higher sensitivity. For comparison, an EIS penicillin biosensor with adsorptively immobilised penicillinase has been also studied. The highest penicillin sensitivity of 100 mV/dec has been observed for the EIS sensor functionalised with the PAH/penicillinase multilayer. The lower and upper detection limit was around 20 µM and 10 mM, respectively. In addition, an incorporation of enzymes in a multilayer prepared by layer-by-layer technique provides a larger amount of immobilised enzymes per sensor area, reduces enzyme leaching effects and thus, enhances the biosensor lifetime (the loss of penicillin sensitivity after 2 months was 10–12%). Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983317 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 884 EP - 890 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kirchner, Patrick A1 - Ng, Yue Ann A1 - Spelthahn, Heiko A1 - Schneider, Andreas A1 - Henkel, Hartmut A1 - Friedrich, Peter A1 - Kolstad, Jens A1 - Berger, Jörg A1 - Keusgen, Michael T1 - Gas sensor investigation based on a catalytically activated thin-film thermopile for H2O2 detection JF - Physica Status Solidi (A) N2 - In aseptic filling systems, hydrogen peroxide vapour is commonly used for the reduction of microbial contaminations in carton packages. In this process, the germicidal efficiency of the vapour depends especially on the H₂O₂ concentration. To monitor the H₂O₂ concentration, a calorimetric H₂O₂ gas sensor based on a catalytically activated thin-film thermopile is investigated. Two different sensor layouts, namely a circular and a linear form, as well as two various material pairs such as tungsten/nickel and gold/nickel, have been examined for the realization of a thin-film thermopile. Additionally, manganese oxide and palladium particles have been compared as responsive catalysts towards H₂O₂. The thin-film sensors have been investigated at various H₂O₂ concentrations, gas temperatures and flow rates. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983309 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 787 EP - 792 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Buniatyan, Vahe V. A1 - Abouzar, Maryam H. A1 - Martirosyan, Norayr W. A1 - Schubert, Jürgen A1 - Gevorgian, Spartak A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - pH-sensitive properties of barium strontium titanate (BST) thin films prepared by pulsed laser deposition technique JF - Physica Status Solidi (A) N2 - pH-sensitive properties of barium strontium titanate (BST) high-k thin films as alternative gate material for field-effect capacitive (bio-)chemical sensors based on an electrolyte-insulator-semiconductor system have been investigated. The BST films of different compositions (Ba0.31Sr0.69TiO3, Ba0.25Sr0.75TiO3 and Mg-doped Ba0.8Sr0.2Mg0.1Ti0.9O3) were deposited by pulsed laser deposition technique from targets fabricated by self-propagating high-temperature synthesis. The realised sensors have been electrochemically characterised by means of impedance-spectroscopy, capacitance–voltage and constant-capacitance method. The sensors possess a Nernstian-like pH sensitivity in the concentration range between pH 3 and 11 with a response time of 5–10 s. An equivalent circuit model for the BST-based capacitive field-effect sensor is discussed. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983310 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 824 EP - 830 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Turek, Monik A1 - Heiden, Wolfgang A1 - Guo, Sharon A1 - Riesen, Alfred A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Krüger, Peter A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Simultaneous detection of cyanide and heavy metals for environmental analysis by means of µISEs JF - Physica Status Solidi (A) N2 - In environmental analysis, cyanide and heavy metals play an important role, because these substances are highly toxic for biological systems. They can lead to chronic and acute diseases. Due to the chemical properties of cyanide it is frequently used for industrial processes such as extraction of silver and gold. Heavy metals can be found as trace elements in nature and are often applied in industries e.g., galvanization processes. Up to now, cyanide and heavy metals can be detected by several sensors separately and their detection is often limited to laboratory investigations. In this publication, with regard to an in situ analysis, a new miniaturized silicon-based sensor system for the simultaneous detection of cyanide and heavy metals in aqueous solutions is presented that is based on chalcogenide glass-based micro ion-selective electrodes (µISEs). The µISEs are incorporated into a specially designed measuring system for the simultaneous detection of heavy metals and cyanide in solutions and validated by simultaneous measurements of Cu2+- and CN−-ions, Cd2+- and CN−- ions and Pb2+- and CN−-ions. The particular sensor system has shown good sensor properties in the µ-molar ion-concentration range. For simultaneous measurements in complex heavy metal and cyanide solutions an intelligent software using fuzzy logic is discussed. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983303 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 817 EP - 823 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Jansen, S. V. A1 - Behbahani, Mehdi A1 - Laumen, M. A1 - Kaufmann, T. A1 - Hormes, M. A1 - Behr, Marek A1 - Schmitz-Rode, T. A1 - Steinseifer, U. T1 - Investigation of Steady Flow Through a Realistic Model of the Thoracic Human Aorta Using 3D Stereo PIV and CFD-Simulation JF - ASAIO Journal Y1 - 2010 U6 - https://doi.org/10.1097/01.mat.0000369377.65122.a3 N1 - American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 VL - 56 IS - 2 SP - 98 PB - Lippincott Williams & Wilkins CY - Philadelphia ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Probst, M. A1 - Mai, A. A1 - Tran, L. A1 - Vonderstein, K. A1 - Keschenau, P. A1 - Linde, T. A1 - Steinseifer, U. A1 - Behr, Marek A1 - Mottaghy, K. T1 - The influence of high shear on thrombosis and hemolysis in artificial organs JF - The International Journal of Artificial Organs Y1 - 2010 SN - 0391-3988 VL - 33 IS - 7 SP - 426 EP - 426 PB - Sage CY - Thousand Oaks ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Nam, J. A1 - Waluga, C. A1 - Behr, Marek A1 - Pasquali, M. A1 - Mottaghy, K. T1 - Modeling and Numerical Analysis of Platelet Activation, Adhesion and Aggregation in Artificial Organs Y1 - 2010 U6 - https://doi.org/10.1097/01.mat.0000369377.65122.a3 N1 - Posterpresentation American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 VL - 56 IS - 2 SP - 85 PB - Lippincott Williams & Wilkins CY - Philadelphia ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Mai, A. A1 - Waluga, C. A1 - Bergmann, B. A1 - Tran, L. A1 - Vonderstein, K. A1 - Behr, Marek A1 - Mottaghy, K. T1 - Numerical Modeling of Flow-Related Thrombus Formation under Physiological and Non-Physiological Flow Conditions JF - Acta Physiologica Y1 - 2010 SN - 1748-1716 N1 - Joint Congress of the Scandinavian and German Physiological Societies, Copenhagen, Denmark, March 27-30, 2010 VL - 198 IS - Supplement 677 SP - 185 ER - TY - JOUR A1 - Siqueira, José R. Jr. A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Associating biosensing properties with the morphological structure of multilayers containing carbon nanotubes on field-effect devices JF - Physica Status Solidi (A) N2 - The control of molecular architecture provided by the layer-by-layer (LbL) technique has led to enhanced biosensors, in which advantageous features of distinct materials can be combined. Full optimization of biosensing performance, however, is only reached if the film morphology is suitable for the principle of detection of a specific biosensor. In this paper, we report a detailed morphology analysis of LbL films made with alternating layers of single-walled carbon nanotubes (SWNTs) and polyamidoamine (PAMAM) dendrimers, which were then covered with a layer of penicillinase (PEN). An optimized performance to detect penicillin G was obtained with 6-bilayer SWNT/PAMAM LbL films deposited on p-Si-SiO2-Ta2O5 chips, used in biosensors based on a capacitive electrolyte-insulator-semiconductor (EIS) and a light-addressable potentiometric sensor (LAPS) structure, respectively. Field-emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM) images indicated that the LbL films were porous, with a large surface area due to interconnection of SWNT into PAMAM layers. This morphology was instrumental for the adsorption of a larger quantity of PEN, with the resulting LbL film being highly stable. The experiments to detect penicillin were performed with constant-capacitance (ConCap) and constant-current (CC) measurements for EIS and LAPS sensors, respectively, which revealed an enhanced detection signal and sensitivity of ca. 100 mV/decade for the field-effect sensors modified with the PAMAM/SWNT LbL film. It is concluded that controlling film morphology is essential for an enhanced performance of biosensors, not only in terms of sensitivity but also stability and response time. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983301 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 781 EP - 786 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Nam, J. A1 - Arora, D. A1 - Behbahani, Mehdi A1 - Probst, M. A1 - Benkowski, R. A1 - Behr, Marek A1 - Pasquali, M. T1 - New computational method in hemolysis analysis for artificial heart pump Y1 - 2010 N1 - Posterpresentation ; American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 ER - TY - JOUR A1 - Ullrich, Sebastian A1 - Grottke, Oliver A1 - Rossaint, Rolf A1 - Staat, Manfred A1 - Deserno, Thomas M. A1 - Kuhlen, Torsten T1 - Virtual Needle Simulation with Haptics for Regional Anaesthesia Y1 - 2010 N1 - IEEE Virtual Reality 2010, Workshop on Medical Virtual Environments, Waltham, MA, USA, March 21, 2010 ER - TY - JOUR A1 - Probst, M. A1 - Behbahani, Mehdi A1 - Borrmann, E. A1 - Elgeti, S. A1 - Nicolai, M. A1 - Behr, Marek T1 - Hemodynamic Modeling for Numerical Analysis and Design of Medical Devices Y1 - 2010 N1 - Posterpresentation ; NIC Symposium 2010 ; 24 - 25 February 2010 Jülich, Germany ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Mai, A. A1 - Bergmann, B. A1 - Waluga, C. A1 - Behr, Marek A1 - Tran, L. A1 - Vonderstein, K. A1 - Mottaghy, K. T1 - Modeling and Numerical Simulation of Blood Damage Y1 - 2010 N1 - Posterpresentation ; Umbrella Symposium "Modelling and Simulation in Medicine, Engineering and Sciences", Forschungszentrum Jülich, January 18-20, 2010 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Probst, M. A1 - Mai, A. A1 - Behr, Marek A1 - Tran, L. A1 - Vonderstein, K. A1 - Mottaghy, K. T1 - Numerical Prediction of Blood Damage in Biomedical Devices Y1 - 2010 N1 - Posterpresentation ; Biomedica Congress, Aachen, March 17-18, 2010 ER - TY - JOUR A1 - Siqueira, Jose R. A1 - Maki, Rafael M. A1 - Paulovich, Fernando V. A1 - Werner, Frederik A1 - Poghossian, Arshak A1 - Oliveira, Maria C. F. de A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Use of information visualization methods eliminating cross talk in multiple sensing units investigated for a light-addressable potentiometric sensor JF - Analytical Chemistry N2 - The integration of nanostructured films containing biomolecules and silicon-based technologies is a promising direction for reaching miniaturized biosensors that exhibit high sensitivity and selectivity. A challenge, however, is to avoid cross talk among sensing units in an array with multiple sensors located on a small area. In this letter, we describe an array of 16 sensing units of a light-addressable potentiometric sensor (LAPS), which was made with layer-by-layer (LbL) films of a poly(amidomine) dendrimer (PAMAM) and single-walled carbon nanotubes (SWNTs), coated with a layer of the enzyme penicillinase. A visual inspection of the data from constant-current measurements with liquid samples containing distinct concentrations of penicillin, glucose, or a buffer indicated a possible cross talk between units that contained penicillinase and those that did not. With the use of multidimensional data projection techniques, normally employed in information visualization methods, we managed to distinguish the results from the modified LAPS, even in cases where the units were adjacent to each other. Furthermore, the plots generated with the interactive document map (IDMAP) projection technique enabled the distinction of the different concentrations of penicillin, from 5 mmol L−1 down to 0.5 mmol L−1. Data visualization also confirmed the enhanced performance of the sensing units containing carbon nanotubes, consistent with the analysis of results for LAPS sensors. The use of visual analytics, as with projection methods, may be essential to handle a large amount of data generated in multiple sensor arrays to achieve high performance in miniaturized systems Y1 - 2010 U6 - https://doi.org/10.1021/ac9024076 SN - 0003-2700 VL - 82 IS - 1 SP - 61 EP - 65 PB - ACS Publications CY - Washington ER - TY - JOUR A1 - Grottke, O. A1 - Braunschweig, T. A1 - Philippen, B. A1 - Gatzweiler, Karl-Heinz A1 - Gronloh, N. A1 - Staat, Manfred A1 - Rossaint, R. A1 - Tolba, R. T1 - A new model for blunt liver injuries in the swine JF - European Surgical Research N2 - Background: To elaborate the impact of new haemostatic agents we developed an instrument for the pressure-controlled induction of blunt liver injuries in a porcine animal model. Materials and Methods: A dilutional coagulopathy of 80% of animal blood volume was induced in 9 anaesthetized pigs. Animals were randomly assigned to be injured with a force of 112 Newton (N) (n = 1), 224 ± 19 N (n = 4) or 355 ± 35 N (n = 4). The impact of injury was measured by blood loss, survival time and coagulation parameters. Liver histology was obtained to evaluate the degree of liver injury. Results: The profound haemodilution resulted in a significant alteration of all coagulation parameters. After inflicting the injury with 355 ± 35 N, both the survival time (30 ± 9 min; p = 0.006) and blood loss (68 ± 16 ml min–1, p = 0.002) were significantly different as compared to injuries with 224 ± 19 N (survival time: 76 ± 20 min, blood loss: 23 ± 4 ml min–1). In contrast, an injury with 112 N led to an insignificant blood loss of only 239 ml. Conclusion: We developed a pressure-controlled clamp that allows for the induction of blunt liver traumas with highly reproducible injuries with a positive correlation with blood loss and survival. Y1 - 2010 U6 - https://doi.org/10.1159/000265053 SN - 1421-9921 VL - 44 IS - 2 SP - 65 EP - 73 PB - Karger CY - Basel ER -