TY - CHAP A1 - Ritz, Thomas A1 - Wallenborn, Ramona ED - Boll-Westermann, Susanne T1 - HMI mobiler Apps zur Organisation multimodaler Mobilität T2 - Mensch & Computer 2013 - Workshopband : 13. fachübergreifende Konferenz für interaktive und kooperative Medien Y1 - 2013 SN - 978-3-486-77855-7 (Print) SN - 978-3-486-78123-6 (E-Book) U6 - https://doi.org/10.1524/9783486781236 SP - 103 EP - 109 PB - Oldenbourg CY - München ER - TY - JOUR A1 - Wolf, Martin A1 - Altgen, Jannik T1 - IT Service Management in der Region Aachen : White Paper Y1 - 2013 SP - 1 EP - 13 ER - TY - CHAP A1 - Bitz, Andreas A1 - Kobus, Thiele A1 - Scheenen, Tom W. J. A1 - Ladd, Mark E. T1 - RF Safety of the Combination of a 31P Tx/Rx Endorectal Coil & a 1H Tx/Rx Body Array for 31P MRSI of the Prostate at 7T (311.) T2 - 20th Annual ISMRM scientific meeting and exhibition 2012 : Melbourne, Australia, 5 - 11 May 2012 Y1 - 2013 SN - 978-1-62276-943-8 SN - 1545-4428 IS - Volume 1 SP - 311 PB - Curran CY - Red Hook, NY ER - TY - JOUR A1 - Czarnecki, Christian A1 - Winkelmann, Axel A1 - Spiliopoulou, Myra T1 - Referenzprozessabläufe für Telekommunikationsunternehmen: Eine Erweiterung des eTOM-Modells JF - Wirtschaftsinformatik N2 - Der Telekommunikationsmarkt erfährt substanzielle Veränderungen. Neue Geschäftsmodelle, innovative Dienstleistungen und Technologien erfordern Reengineering, Transformation und Prozessstandardisierung. Mit der Enhanced Telecom Operation Map (eTOM) bietet das TM Forum ein international anerkanntes de facto Referenz-Prozess-Framework basierend auf spezifischen Anforderungen und Ausprägungen der Telekommunikationsindustrie an. Allerdings enthält dieses Referenz-Framework nur eine hierarchische Sammlung von Prozessen auf unterschiedlichen Abstraktionsebenen. Eine Kontrollsicht verstanden als sequenzielle Anordnung von Aktivitäten und daraus resultierend ein realer Prozessablauf fehlt ebenso wie eine Ende-zu-Ende-Sicht auf den Kunden. In diesem Artikel erweitern wir das eTOM-Referenzmodell durch Referenzprozessabläufe, in welchen wir das Wissen über Prozesse in Telekommunikationsunternehmen abstrahieren und generalisieren. Durch die Referenzprozessabläufe werden Unternehmen bei dem strukturierten und transparenten (Re-)Design ihrer Prozesse unterstützt. Wir demonstrieren die Anwendbarkeit und Nützlichkeit unserer Referenzprozessabläufe in zwei Fallstudien und evaluieren diese anhand von Kriterien für die Bewertung von Referenzmodellen. Die Referenzprozessabläufe wurden vom TM Forum in den Standard aufgenommen und als Teil von eTOM Version 9 veröffentlicht. Darüber hinaus diskutieren wir die Komponenten unseres Ansatzes, die auch außerhalb der Telekommunikationsindustrie angewandt werden können. KW - Prozessstandardisierung KW - Prozessabläufe KW - Prozessmodellierung KW - Referenzmodellierung KW - eTOM Y1 - 2013 U6 - https://doi.org/10.1007/s11576-013-0351-9 SN - 1861-8936 VL - 55 IS - 2 SP - 83 EP - 97 PB - Springer Fachmedien CY - Wiesbaden ER - TY - THES A1 - Czarnecki, Christian T1 - Entwicklung einer referenzmodellbasierten Unternehmensarchitektur für die Telekommunikationsindustrie N2 - Die Telekommunikationsindustrie hat in den letzten Jahrzehnten einen enormen Wandel vollzogen. Für Telekommunikationsunternehmen erfordert dies fundamentale Umstrukturierungen von Strategie, Prozessen, Anwendungssystemen und Netzwerktechnologien. Dabei spielen Unternehmensarchitekturen und Referenzmodelle eine wichtige Rolle. Zwar existieren in der Praxis anerkannte Referenzmodelle, aber wie sind diese für eine systematische Transformation zu gestalten? Wie sieht eine konkrete Lösung für die Telekommunikationsindustrie aus? Als Antwort stellt Christian Czarnecki in seinem Buch eine referenzmodellbasierte Unternehmensarchitektur vor. Basierend auf einer umfangreichen Untersuchung von Transformationsprojekten werden Probleme und Anforderungen der Praxis identifiziert, für die mit Methoden der Unternehmenstransformation, Referenzmodellierung und Unternehmensarchitektur ein Lösungsvorschlag entwickelt und evaluiert wird. Dieser besteht u. a. aus detaillierten Anwendungsfällen, Referenzprozessabläufen, einer Zuordnung von Prozessen zu Anwendungssystemen sowie Handlungsempfehlungen zur Virtualisierung. Für Wissenschaftler und Studierende der Wirtschaftsinformatik zeigt das Buch neue Erkenntnisse einer anwendungsorientierten Referenzmodellierung. Für Praktiker liefert es eine methodisch fundierte Lösung für die aktuellen Transformationsbedarfe der Telekommunikationsindustrie. Christian Czarnecki arbeitet seit 2004 als Unternehmensberater und hat viele Telekommunikationsunternehmen bei deren Transformation begleitet. In 2013 erfolgte die Promotion zum Doktoringenieur an der Otto-von-Guericke-Universität Magdeburg. KW - Referenzmodelle KW - Unternehmensstrukturen KW - Management Y1 - 2013 SN - 9783832535100 PB - Logos CY - Berlin ER - TY - JOUR A1 - Orzada, Stephan A1 - Johst, Sören A1 - Maderwald, Stefan A1 - Bitz, Andreas A1 - Solbach, Klaus A1 - Ladd, Mark E. T1 - Mitigation of B1(+) inhomogeneity on single-channel transmit systems with TIAMO JF - Magnetic Resonance in Medicine Y1 - 2013 U6 - https://doi.org/10.1002/mrm.24453 SN - 1522-2594 VL - 70 IS - 1 SP - 290 EP - 294 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Umutlu, Lale A1 - Bitz, Andreas A1 - Maderwald, Stefan A1 - Orzada, Stephan A1 - Kinner, Sonja A1 - Kraff, Oliver A1 - Brote, Irina A1 - Ladd, Susanne C. A1 - Schroeder, Tobias A1 - Forsting, Michael T1 - Contrast-enhanced ultra-high-field liver MRI: a feasibility trial JF - European Journal of Radiology Y1 - 2013 U6 - https://doi.org/10.1016/j.ejrad.2011.07.004 SN - 0720-048X VL - 82 IS - 5 SP - 760 EP - 767 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Umutlu, Lale A1 - Kraff, Oliver A1 - Fischer, Anja A1 - Kinner, Sonja A1 - Maderwald, Stefan A1 - Nassenstein, Kai A1 - Nensa, Felix A1 - Grüneisen, Johannes A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Forsting, Michael A1 - Ladd, Mark E. A1 - Lauenstein, Thomas C. T1 - Seven-Tesla MRI of the female pelvis JF - European Radiology Y1 - 2013 U6 - https://doi.org/10.1007/s00330-013-2868-0 SN - 1432-1084 VL - 23 IS - 9 SP - 2364 EP - 2373 PB - Springer CY - Berlin ER - TY - JOUR A1 - Bitz, Andreas A1 - Felder, Jorg A1 - Wittig, Tilmann T1 - Designing MRI Coils with Aid of Simulation JF - Microwaves & RF Y1 - 2013 SN - 0745-2993 VL - 52 IS - 7 SP - 56 PB - Penton CY - Cleveland, Ohio ER - TY - JOUR A1 - Kraff, Oliver A1 - Wrede, Karsten H. A1 - Schoemberg, Tobias A1 - Dammann, Philipp A1 - Noureddine, Yacine A1 - Orzada, Stephan A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - MR safety assessment of potential RF heating from cranial fixation plates at 7 T JF - Medical Physics Y1 - 2013 U6 - https://doi.org/10.1118/1.4795347 SN - 2473-4209 VL - 40 IS - 4 SP - 042302-1 EP - 042302-10 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Umutlu, L. A1 - Maderwald, S. A1 - Kinner, S. A1 - Kraff, O. A1 - Bitz, Andreas A1 - Orzada, S. A1 - Johst, S. A1 - Wrede, K. A1 - Forsting, M. A1 - Ladd, M. E. A1 - Lauenstein, T. C. A1 - Quick, H. H. T1 - First-pass contrast-enhanced renal MRA at 7 Tesla: initial results JF - European Radiology Y1 - 2013 U6 - https://doi.org/10.1007/s00330-012-2666-0 SN - 1432-1084 VL - 23 IS - 4 SP - 1059 EP - 1066 PB - Springer CY - Berlin ER - TY - GEN A1 - Waiczies, Helmar A1 - Kühne, André A1 - Winter, Lukas A1 - Frauenrath, Tobias A1 - Hoffmann, Werner A1 - Ittermann, Bernd A1 - Waiczies, Sonia A1 - Niendorf, Thoralf T1 - Towards theranostics of rheumatoid arthritis: 1H/19F imaging of non-steroidal anti-inflammatory drugs in hand and wrist at 7 Tesla T2 - 2013 ISMRM Annual Meeting Proceedings N2 - We have developed a double-tuned ¹H/¹⁹F birdcage resonator dedicated for hand and wrist imaging at 7 T to locally image non-steroidal anti-inflammatory drugs (NSAID) such as 2-{[3-(Trifluoromethyl) phenyl]amino}benzoic acid. The preliminary in vivo images acquired by the double-tuned ¹H/¹⁹F birdcage resonator demonstrate the feasibility for ¹H/¹⁹F hand- and wrist-imaging at 7 T. While the diagnostic quality of the coil needs to be assessed in patients with inflammatory rheumatoid disease, first ¹⁹F images of the NSAID are encouraging, and point towards the prospect of applying ¹⁹F-MRI to visualize and quantify the concentration of therapeutically-active compound at the sites of inflammation. Y1 - 2013 SN - 1545-4428 N1 - ISMRM 21st Annual Meeting & Exhibition, 20-26 April 2013, Salt Lake City, Utah, USA ER - TY - JOUR A1 - Gräßl, Andreas A1 - Renz, Wolfgang A1 - Hezel, Fabian A1 - Dieringer, Matthias A. A1 - Winter, Lukas A1 - Özerdem, Celal A1 - Rieger, Jan A1 - Kellmann, Peter A1 - Santoro, Davide A1 - Lindel, Tomasz D. A1 - Frauenrath, Tobias A1 - Pfeiffer, Harald A1 - Niendorf, Thoralf T1 - Modular 32-channel transceiver coil array for cardiac MRI at 7.0T JF - Magnetic Resonance in Medicine N2 - Purpose To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T. Methods The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study. Results Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly. Conclusion The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T. Y1 - 2013 U6 - https://doi.org/10.1002/mrm.24903 SN - 1522-2594 VL - 72 IS - 1 SP - 276 EP - 290 PB - Wiley-Liss CY - New York ER -