TY - JOUR A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Schäfer, Lena C. A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Maderwald, Stefan T1 - Open design eight-channel transmit/receive coil for high-resolution and real-time ankle imaging at 7 T JF - Medical Physics N2 - Purpose: At 1.5 T, real-time MRI of joint movement has been shown to be feasible. However, 7 T, provides higher SNR and thus an improved potential for parallel imaging acceleration. The purpose of this work was to build an open, U-shaped eight-channel transmit/receive microstrip coil for 7 T MRI to enable high-resolution and real-time imaging of the moving ankle joint. Methods: A U-shaped eight-channel transmit/receive array for the human ankle was built.urn:x-wiley:00942405:mp3399:equation:mp3399-math-0001-parameters and urn:x-wiley:00942405:mp3399:equation:mp3399-math-0002-factor were measured. SAR calculations of different ankle postures were performed to ensure patient safety. Inhomogeneities in the transmit field consequent to the open design were compensated for by the use of static RF shimming. High-resolution and real-time imaging was performed in human volunteers. Results: The presented array showed good performance with regard to patient comfort and image quality. High acceleration factors of up to 4 are feasible without visible acceleration artifacts. Reasonable image homogeneity was achieved with RF shimming. Conclusions: Open, noncylindrical designs for transmit/receive coils are practical at 7 T and real-time imaging of the moving joint is feasible with the presented coil design. Y1 - 2011 U6 - https://doi.org/10.1118/1.3553399 SN - 2473-4209 VL - 38 IS - 3 SP - 1162 EP - 1167 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Prochnow, Nora A1 - Gebing, Tina A1 - Ladage, Kerstin A1 - Krause-Finkeldey, Dorothee A1 - Ourdi, Abessamad El A1 - Bitz, Andreas A1 - Streckert, Joachim A1 - Hansen, Volkert A1 - Dermietzel, Rolf T1 - Electromagnetic field effect or simply stress? Effects of UMTS exposure on hippocampal longterm plasticity in the context of procedure related hormone release JF - PLoS one N2 - Harmful effects of electromagnetic fields (EMF) on cognitive and behavioural features of humans and rodents have been controversially discussed and raised persistent concern about adverse effects of EMF on general brain functions. In the present study we applied radio-frequency (RF) signals of the Universal Mobile Telecommunications System (UMTS) to full brain exposed male Wistar rats in order to elaborate putative influences on stress hormone release (corticosteron; CORT and adrenocorticotropic hormone; ACTH) and on hippocampal derived synaptic long-term plasticity (LTP) and depression (LTD) as electrophysiological hallmarks for memory storage and memory consolidation. Exposure was computer controlled providing blind conditions. Nominal brain-averaged specific absorption rates (SAR) as a measure of applied mass-related dissipated RF power were 0, 2, and 10 W/kg over a period of 120 min. Comparison of cage exposed animals revealed, regardless of EMF exposure, significantly increased CORT and ACTH levels which corresponded with generally decreased field potential slopes and amplitudes in hippocampal LTP and LTD. Animals following SAR exposure of 2 W/kg (averaged over the whole brain of 2.3 g tissue mass) did not differ from the sham-exposed group in LTP and LTD experiments. In contrast, a significant reduction in LTP and LTD was observed at the high power rate of SAR (10 W/kg). The results demonstrate that a rate of 2 W/kg displays no adverse impact on LTP and LTD, while 10 W/kg leads to significant effects on the electrophysiological parameters, which can be clearly distinguished from the stress derived background. Our findings suggest that UMTS exposure with SAR in the range of 2 W/kg is not harmful to critical markers for memory storage and memory consolidation, however, an influence of UMTS at high energy absorption rates (10 W/kg) cannot be excluded. Y1 - 2011 U6 - https://doi.org/10.1371/journal.pone.0019437 VL - 6 IS - 5 PB - PLOS CY - San Francisco ER - TY - JOUR A1 - Yazdanbakhsh, Pedram A1 - Solbach, Klaus A1 - Bitz, Andreas T1 - Variable power combiner for RF mode shimming in 7-T MR imaging JF - IEEE Transaction on Biomedical Engineering N2 - This contribution discusses the utilization of RF power in an MRI system with RF mode shimming which enables the superposition of circularly polarized modes of a transmit RF coil array driven by a Butler matrix. Since the required power for the individual modes can vary widely, mode-shimming can result in a significant underutilization of the total available RF power. A variable power combiner (VPC) is proposed to improve the power utilization: it can be realized as a reconfiguration of the MRI transmit system by the inclusion of one additional matrix network which receives the power from all transmit amplifiers at its input ports and provides any desired (combined) power distribution at its output ports by controlling the phase and amplitude of the amplifiers’ input signals. The power distribution at the output ports of the VPC is then fed into the “mode” ports of the coil array Butler matrix in order to superimpose the spatial modes at the highest achievable power utilization. The VPC configuration is compared to the standard configuration of the transmit chain of our MRI system with 8 transmit channels and 16 coils. In realistic scenarios, improved power utilization was achieved from 17% to 60% and from 14% to 55% for an elliptical phantom and a region of interest in the abdomen, respectively, and an increase of the power utilization of 1 dB for a region of interest in the upper leg. In general, it is found that the VPC allows significant improvement in power utilization when the shimming solution demands only a few modes to be energized, while the technique can yield loss in power utilization in cases with many modes required at high power level. Y1 - 2012 U6 - https://doi.org/10.1109/TBME.2012.2205926 SN - 1558-2531 VL - 59 IS - 9 SP - 2549 EP - 2557 PB - IEEE CY - New York ER - TY - JOUR A1 - Umutlu, Lale A1 - Bitz, Andreas A1 - Maderwald, Stefan A1 - Orzada, Stephan A1 - Kinner, Sonja A1 - Kraff, Oliver A1 - Brote, Irina A1 - Ladd, Susanne C. A1 - Schroeder, Tobias A1 - Forsting, Michael T1 - Contrast-enhanced ultra-high-field liver MRI: a feasibility trial JF - European Journal of Radiology Y1 - 2013 U6 - https://doi.org/10.1016/j.ejrad.2011.07.004 SN - 0720-048X VL - 82 IS - 5 SP - 760 EP - 767 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Finger, Felix T1 - Senkrechtstarter: FH-Absolvent wird für Transportdrohne ausgezeichnet JF - campushunter: das etwas andere Karrieremagazin - Wintersemester 16/17 Y1 - 2016 SN - 2196-9426 IS - 17. Regionalausgabe Aachen SP - 116 EP - 117 PB - Campushunter Media CY - Heidelberg ER - TY - JOUR A1 - Orzada, Stephan A1 - Maderwald, Stefan A1 - Poser, Benedikt Andreas A1 - Bitz, Andreas A1 - Quick, Harald H. A1 - Ladd, Mark E. T1 - RF excitation using time interleaved acquisition of modes (TIAMO) to address B1 inhomogeneity in high-field MRI JF - Magnetic Resonance in Medicine N2 - As the field strength and, therefore, the operational frequency in MRI is increased, the wavelength approaches the size of the human head/body, resulting in wave effects, which cause signal decreases and dropouts. Several multichannel approaches have been proposed to try to tackle these problems, including RF shimming, where each element in an array is driven by its own amplifier and modulated with a certain (constant) amplitude and phase relative to the other elements, and Transmit SENSE, where spatially tailored RF pulses are used. In this article, a relatively inexpensive and easy to use imaging scheme for 7 Tesla imaging is proposed to mitigate signal voids due to B1 field inhomogeneity. Two time-interleaved images are acquired using a different excitation mode for each. By forming virtual receive elements, both images are reconstructed together using GRAPPA to achieve a more homogeneous image, with only small SNR and SAR penalty in head and body imaging at 7 Tesla. Y1 - 2010 U6 - https://doi.org/10.1002/mrm.22527 SN - 1522-2594 VL - 64 IS - 2 SP - 327 EP - 333 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Kobus, Thiele A1 - Bitz, Andreas A1 - Uden, Mark J. van A1 - Lagemaat, Miram W. A1 - Rothgang, Eva A1 - Orzada, Stephan A1 - Heerschap, Arend A1 - Scheenen, Tom W. J. T1 - In vivo 31P MR spectroscopic imaging of the human prostate at 7 T: safety and feasibility JF - Magnetic Resonance in Medicine N2 - 31P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D 31P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a 31P endorectal coil was developed and combined with an eight-channel 1H body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and Burn:x-wiley:07403194:media:MRM24175:tex2gif-stack-1 measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the 31P endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel 1H array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the 1H array coil was allowed. For transmitting with the 31P endorectal coil, our safety limit of less than 1°C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D 31P MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm3. The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer. Y1 - 2012 U6 - https://doi.org/10.1002/mrm.24175 SN - 1522-2594 VL - 68 IS - 6 SP - 1683 EP - 1695 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Orzada, S. A1 - Maderwald, S. A1 - Poser, B. A. A1 - Johst, S. A1 - Kannengiesser, S. A1 - Ladd, M. E. A1 - Bitz, Andreas T1 - Time-interleaved acquisition of modes: an analysis of SAR and image contrast implications JF - Magnetic Resonance in Medicine N2 - s the magnetic field strength and therefore the operational frequency in MRI are increased, the radiofrequency wavelength approaches the size of the human head/body, resulting in wave effects which cause signal decreases and dropouts. Especially, whole-body imaging at 7 T and higher is therefore challenging. Recently, an acquisition scheme called time-interleaved acquisition of modes has been proposed to tackle the inhomogeneity problems in high-field MRI. The basic premise is to excite two (or more) different Burn:x-wiley:07403194:media:MRM23081:tex2gif-stack-1 modes using static radiofrequency shimming in an interleaved acquisition, where the complementary radiofrequency patterns of the two modes can be exploited to improve overall signal homogeneity. In this work, the impact of time-interleaved acquisition of mode on image contrast as well as on time-averaged specific absorption rate is addressed in detail. Time-interleaved acquisition of mode is superior in Burn:x-wiley:07403194:media:MRM23081:tex2gif-stack-2 homogeneity compared with conventional radiofrequency shimming while being highly specific absorption rate efficient. Time-interleaved acquisition of modes can enable almost homogeneous high-field imaging throughout the entire field of view in PD, T2, and T2*-weighted imaging and, if a specified homogeneity criterion is met, in T1-weighted imaging as well. Y1 - 2012 U6 - https://doi.org/10.1002/mrm.23081 SN - 1522-2594 VL - 67 IS - 4 SP - 1033 EP - 1041 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Orzada, Stephan A1 - Johst, Sören A1 - Maderwald, Stefan A1 - Bitz, Andreas A1 - Solbach, Klaus A1 - Ladd, Mark E. T1 - Mitigation of B1(+) inhomogeneity on single-channel transmit systems with TIAMO JF - Magnetic Resonance in Medicine Y1 - 2013 U6 - https://doi.org/10.1002/mrm.24453 SN - 1522-2594 VL - 70 IS - 1 SP - 290 EP - 294 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Umutlu, Lale A1 - Orzada, Stephan A1 - Kinner, Sonja A1 - Maderwald, Stefan A1 - Bronte, Irina A1 - Bitz, Andreas A1 - Kraff, Oliver A1 - Ladd, Susanne C. A1 - Antoch, Gerald A1 - Ladd, Mark E. A1 - Quick, Harald H. A1 - Lauenstein, Thomas C. T1 - Renal imaging at 7 Tesla: preliminary results JF - European Radiology N2 - Objective To investigate the feasibility of 7T MR imaging of the kidneys utilising a custom-built 8-channel transmit/receive radiofrequency body coil. Methods In vivo unenhanced MR was performed in 8 healthy volunteers on a 7T whole-body MR system. After B0 shimming the following sequences were obtained: 1) 2D and 3D spoiled gradient-echo sequences (FLASH, VIBE), 2) T1-weighted 2D in and opposed phase 3) True-FISP imaging and 4) a T2-weighted turbo spin echo (TSE) sequence. Visual evaluation of the overall image quality was performed by two radiologists. Results Renal MRI at 7T was feasible in all eight subjects. Best image quality was found using T1-weighted gradient echo MRI, providing high anatomical details and excellent conspicuity of the non-enhanced vasculature. With successful shimming, B1 signal voids could be effectively reduced and/or shifted out of the region of interest in most sequence types. However, T2-weighted TSE imaging remained challenging and strongly impaired because of signal heterogeneities in three volunteers. Conclusion The results demonstrate the feasibility and diagnostic potential of dedicated 7T renal imaging. Further optimisation of imaging sequences and dedicated RF coil concepts are expected to improve the acquisition quality and ultimately provide high clinical diagnostic value. Y1 - 2011 SN - 1432-1084 VL - 21 IS - 4 SP - 841 EP - 849 PB - Springer CY - Berlin ER - TY - JOUR A1 - Umutlu, L. A1 - Maderwald, S. A1 - Kinner, S. A1 - Kraff, O. A1 - Bitz, Andreas A1 - Orzada, S. A1 - Johst, S. A1 - Wrede, K. A1 - Forsting, M. A1 - Ladd, M. E. A1 - Lauenstein, T. C. A1 - Quick, H. H. T1 - First-pass contrast-enhanced renal MRA at 7 Tesla: initial results JF - European Radiology Y1 - 2013 U6 - https://doi.org/10.1007/s00330-012-2666-0 SN - 1432-1084 VL - 23 IS - 4 SP - 1059 EP - 1066 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kraff, Oliver A1 - Wrede, Karsten H. A1 - Schoemberg, Tobias A1 - Dammann, Philipp A1 - Noureddine, Yacine A1 - Orzada, Stephan A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - MR safety assessment of potential RF heating from cranial fixation plates at 7 T JF - Medical Physics Y1 - 2013 U6 - https://doi.org/10.1118/1.4795347 SN - 2473-4209 VL - 40 IS - 4 SP - 042302-1 EP - 042302-10 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Bitz, Andreas A1 - Felder, Jorg A1 - Wittig, Tilmann T1 - Designing MRI Coils with Aid of Simulation JF - Microwaves & RF Y1 - 2013 SN - 0745-2993 VL - 52 IS - 7 SP - 56 PB - Penton CY - Cleveland, Ohio ER - TY - JOUR A1 - Umutlu, Lale A1 - Kraff, Oliver A1 - Fischer, Anja A1 - Kinner, Sonja A1 - Maderwald, Stefan A1 - Nassenstein, Kai A1 - Nensa, Felix A1 - Grüneisen, Johannes A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Forsting, Michael A1 - Ladd, Mark E. A1 - Lauenstein, Thomas C. T1 - Seven-Tesla MRI of the female pelvis JF - European Radiology Y1 - 2013 U6 - https://doi.org/10.1007/s00330-013-2868-0 SN - 1432-1084 VL - 23 IS - 9 SP - 2364 EP - 2373 PB - Springer CY - Berlin ER - TY - JOUR A1 - Maas, Marnix C. A1 - Vos, Eline K. A1 - Lagemaat, Miriam W. A1 - Bitz, Andreas A1 - Orzada, Stephan A1 - Kobus, Thiele A1 - Kraff, Oliver A1 - Maderwald, Stefan A1 - Ladd, Mark E. A1 - Scheenen, Tom W. J. T1 - Feasibility of T₂-weighted turbo spin echo imaging of the human prostate at 7 tesla JF - Magnetic Resonance in Medicine N2 - Purpose To demonstrate that high quality T₂-weighted (T2w) turbo spin-echo (TSE) imaging of the complete prostate can be achieved routinely and within safety limits at 7 T, using an external transceive body array coil only. Methods Nine healthy volunteers and 12 prostate cancer patients were scanned on a 7 T whole-body system. Preparation consisted of B₀ and radiofrequency shimming and localized flip angle calibration. T₁ and T₂ relaxation times were measured and used to define the T2w-TSE protocol. T2w imaging was performed using a TSE sequence (pulse repetition time/echo time 3000–3640/71 ms) with prolonged excitation and refocusing pulses to reduce specific absorption rate. Results High quality T2w TSE imaging was performed in less than 2 min in all subjects. Tumors of patients with gold-standard tumor localization (MR-guided biopsy or prostatectomy) were well visualized on 7 T imaging (n = 3). The number of consecutive slices achievable within a 10-g averaged specific absorption rate limit of 10 W/kg was ≥28 in all subjects, sufficient for full prostate coverage with 3-mm slices in at least one direction. Conclusion High quality T2w TSE prostate imaging can be performed routinely and within specific absorption rate limits at 7 T with an external transceive body array. Y1 - 2014 U6 - https://doi.org/10.1002/mrm.24818 SN - 1522-2594 VL - 71 IS - 5 SP - 1711 EP - 1719 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Pyschny, D. A1 - Döring, Bernd A1 - Feldmann, M. T1 - Ermittlung der thermischen Leistungsfähigkeit des neuartigen multifunktionalen Verbunddeckensystems InaDeck JF - Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen Y1 - 2014 SN - 0005-6650 N1 - Printausgabe in der Bibliothek Bayernallee vorhanden: 13 Z 049-2014 VL - 89 IS - 3 SP - 116 EP - 124 PB - VDI Fachmedien CY - Düsseldorf ER - TY - JOUR A1 - Lagemaat, Miriam W. A1 - Vos, Eline K. A1 - Maas, Marnix C. A1 - Bitz, Andreas A1 - Orzada, Stephan A1 - Uden, Mark J. van A1 - Kobus, Thiele A1 - Heerschap, Arend A1 - Scheenen, Tom W. J. T1 - Phosphorus magnetic resonance spectroscopic imaging at 7 T in patients with prostate cancer JF - Investigative Radiology N2 - Objectives The aim of this study was to identify characteristics of phosphorus (³¹P) spectra of the human prostate and to investigate changes of individual phospholipid metabolites in prostate cancer through in vivo ³¹P magnetic resonance spectroscopic imaging (MRSI) at 7 T. Materials and Methods In this institutional review board–approved study, 15 patients with biopsy-proven prostate cancer underwent T₂-weighted magnetic resonance imaging and 3-dimensional ³¹P MRSI at 7 T. Voxels were selected at the tumor location, in normal-appearing peripheral zone tissue, normal-appearing transition zone tissue, and in the base of the prostate close to the seminal vesicles. Phosphorus metabolite ratios were determined and compared between tissue types. Results Signals of phosphoethanolamine (PE) and phosphocholine (PC) were present and well resolved in most ³¹P spectra in the prostate. Glycerophosphocholine signals were observable in 43% of the voxels in malignant tissue, but in only 10% of the voxels in normal-appearing tissue away from the seminal vesicles. In many spectra, independent of tissue type, 2 peaks resonated in the chemical shift range of inorganic phosphate, possibly representing 2 separate pH compartments. The PC/PE ratio in the seminal vesicles was highly elevated compared with the prostate in 5 patients. A considerable overlap of ³¹P metabolite ratios was found between prostate cancer and normal-appearing prostate tissue, preventing direct discrimination of these tissues. The only 2 patients with high Gleason scores tumors (≥4+5) presented with high PC and glycerophosphocholine levels in their cancer lesions. Conclusions Phosphorus MRSI at 7 T shows distinct features of phospholipid metabolites in the prostate gland and its surrounding structures. In this exploratory study, no differences in ³¹P metabolite ratios were observed between prostate cancer and normal-appearing prostate tissue possibly because of the partial volume effects of small tumor foci in large MRSI voxels. Y1 - 2014 U6 - https://doi.org/10.1097/RLI.0000000000000012 SN - 1536-0210 VL - 49 IS - 5 SP - 363 EP - 372 PB - Lippincott Williams & Wilkins CY - Philadelphia, Pa. ER - TY - JOUR A1 - Theysohn, Jens M. A1 - Kraff, Oliver A1 - Eilers, Kristina A1 - Andrade, Dorian A1 - Gerwig, Marcus A1 - Timmann, Dagmar A1 - Schmitt, Franz A1 - Ladd, Mark E. A1 - Ladd, Susanne C. A1 - Bitz, Andreas T1 - Vestibular effects of a 7 Tesla MRI examination compared to 1.5 T and 0 T in healthy volunteers JF - PLoS one N2 - Ultra-high-field MRI (7 Tesla (T) and above) elicits more temporary side-effects compared to 1.5 T and 3 T, e.g. dizziness or “postural instability” even after exiting the scanner. The current study aims to assess quantitatively vestibular performance before and after exposure to different MRI scenarios at 7 T, 1.5 T and 0 T. Sway path and body axis rotation (Unterberger's stepping test) were quantitatively recorded in a total of 46 volunteers before, 2 minutes after, and 15 minutes after different exposure scenarios: 7 T head MRI (n = 27), 7 T no RF (n = 22), 7 T only B₀ (n = 20), 7 T in & out B₀ (n = 20), 1.5 T no RF (n = 20), 0 T (n = 15). All exposure scenarios lasted 30 minutes except for brief one minute exposure in 7 T in & out B₀. Both measures were documented utilizing a 3D ultrasound system. During sway path evaluation, the experiment was repeated with eyes both open and closed. Sway paths for all long-lasting 7 T scenarios (normal, no RF, only B₀) with eyes closed were significantly prolonged 2 minutes after exiting the scanner, normalizing after 15 minutes. Brief exposure to 7 T B₀ or 30 minutes exposure to 1.5 T or 0 T did not show significant changes. End positions after Unterberger's stepping test were significantly changed counter-clockwise after all 7 T scenarios, including the brief in & out B₀ exposure. Shorter exposure resulted in a smaller alteration angle. In contrast to sway path, reversal of changes in body axis rotation was incomplete after 15 minutes. 1.5 T caused no rotational changes. The results show that exposure to the 7 Tesla static magnetic field causes only a temporary dysfunction or “over-compensation” of the vestibular system not measurable at 1.5 or 0 Tesla. Radiofrequency fields, gradient switching, and orthostatic dysregulation do not seem to play a role. Y1 - 2014 U6 - https://doi.org/10.1371/journal.pone.0092104 SN - 1932-6203 VL - 9 IS - 3 PB - PLOS CY - San Francisco ER - TY - JOUR A1 - Lagemaat, Miriam W. A1 - Maas, Marnix C. A1 - Vos, Eline K. A1 - Bitz, Andreas A1 - Orzada, Stephan A1 - Weiland, Elisabeth A1 - Uden, Mark J. van A1 - Kobus, Thiele A1 - Heerschap, Arend A1 - Scheenen, Tom W. J. T1 - (31) P MR spectroscopic imaging of the human prostate at 7 T: T1 relaxation times, Nuclear Overhauser Effect, and spectral characterization JF - Magnetic Resonance in Medicine Y1 - 2015 U6 - https://doi.org/10.1002/mrm.25209 SN - 1522-2594 VL - 73 IS - 3 SP - 909 EP - 920 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Vos, E. K. A1 - Lagemaat, M. W. A1 - Barentsz, J. O. A1 - Fütterer, J. J. A1 - Zamecnik, P. A1 - Roozen, H. A1 - Orzada, S. A1 - Bitz, Andreas A1 - Maas, M. C. A1 - Scheenen, T. W. J. T1 - Image quality and cancer visibility of T2-weighted Magnetic Resonance Imaging of the prostate at 7 Tesla JF - European Radiology N2 - Objectives To assess the image quality of T2-weighted (T2w) magnetic resonance imaging of the prostate and the visibility of prostate cancer at 7 Tesla (T). Materials & methods Seventeen prostate cancer patients underwent T2w imaging at 7T with only an external transmit/receive array coil. Three radiologists independently scored images for image quality, visibility of anatomical structures, and presence of artefacts. Krippendorff’s alpha and weighted kappa statistics were used to assess inter-observer agreement. Visibility of prostate cancer lesions was assessed by directly linking the T2w images to the confirmed location of prostate cancer on histopathology. Results T2w imaging at 7T was achievable with ‘satisfactory’ (3/5) to ‘good’ (4/5) quality. Visibility of anatomical structures was predominantly scored as ‘satisfactory’ (3/5) and ‘good’ (4/5). If artefacts were present, they were mostly motion artefacts and, to a lesser extent, aliasing artefacts and noise. Krippendorff’s analysis revealed an α = 0.44 between three readers for the overall image quality scores. Clinically significant cancer lesions in both peripheral zone and transition zone were visible at 7T. Conclusion T2w imaging with satisfactory to good quality can be routinely acquired, and cancer lesions were visible in patients with prostate cancer at 7T using only an external transmit/receive body array coil. Y1 - 2014 U6 - https://doi.org/10.1007/s00330-014-3234-6 SN - 1432-1084 VL - 24 IS - 8 SP - 1950 EP - 1958 PB - Springer CY - Cham ER - TY - JOUR A1 - Lagemaat, Miriam W. A1 - Breukels, Vincent A1 - Vos, Eline K. A1 - B., Adam A1 - Uden, Mark J. van A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Maas, Marnix C. A1 - Scheenen, Tom W. J. T1 - ¹H MR spectroscopic imaging of the prostate at 7T using spectral-spatial pulses JF - Magnetic Resonance in Medicine N2 - Purpose To assess the feasibility of prostate ¹H MR spectroscopic imaging (MRSI) using low-power spectral-spatial (SPSP) pulses at 7T, exploiting accurate spectral selection and spatial selectivity simultaneously. Methods A double spin-echo sequence was equipped with SPSP refocusing pulses with a spectral selectivity of 1 ppm. Three-dimensional prostate ¹H-MRSI at 7T was performed with the SPSP-MRSI sequence using an 8-channel transmit array coil and an endorectal receive coil in three patients with prostate cancer and in one healthy subject. No additional water or lipid suppression pulses were used. Results Prostate ¹H-MRSI could be obtained well within specific absorption rate (SAR) limits in a clinically feasible time (10 min). Next to the common citrate signals, the prostate spectra exhibited high spermine signals concealing creatine and sometimes also choline. Residual lipid signals were observed at the edges of the prostate because of limitations in spectral and spatial selectivity. Conclusion It is possible to perform prostate ¹H-MRSI at 7T with a SPSP-MRSI sequence while using separate transmit and receive coils. This low-SAR MRSI concept provides the opportunity to increase spatial resolution of MRSI within reasonable scan times. Y1 - 2016 U6 - https://doi.org/10.1002/mrm.25569 SN - 1522-2594 VL - 75 IS - 3 SP - 933 EP - 945 PB - International Society for Magnetic Resonance in Medicine ER - TY - JOUR A1 - Noureddine, Yacine A1 - Bitz, Andreas A1 - Ladd, Mark E. A1 - Thürling, Markus A1 - Ladd, Susanne C. A1 - Schaefers, Gregor A1 - Kraff, Oliver T1 - Experience with magnetic resonance imaging of human subjects with passive implants and tattoos at 7 T: a retrospective study JF - Magnetic Resonance Materials in Physics, Biology and Medicine Y1 - 2015 U6 - https://doi.org/10.1007/s10334-015-0499-y SN - 1352-8661 VL - 28 IS - 6 SP - 577 EP - 590 PB - Springer CY - Berlin ER - TY - JOUR A1 - Bank, Bart L. van de A1 - Orzada, Stephan A1 - Smits, Frits A1 - Lagemaat, Miriam W. A1 - Rodgers, Christopher T. A1 - Bitz, Andreas A1 - Scheenen, Tom W. J. T1 - Optimized (31) P MRS in the human brain at 7 T with a dedicated RF coil setup JF - NMR in Biomedicine Y1 - 2015 U6 - https://doi.org/10.1002/nbm.3422 SN - 1099-1492 VL - 28 IS - 11 SP - 1570 EP - 1578 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Schmidt, K. A1 - Forkmann, K. A1 - Sinke, C. A1 - Gratz, M. A1 - Bitz, Andreas A1 - Bingel, U. T1 - The differential effect of trigeminal vs. peripheral pain stimulation on visual processing and memory encoding is influenced by pain-related fear JF - NeuroImage N2 - Compared to peripheral pain, trigeminal pain elicits higher levels of fear, which is assumed to enhance the interruptive effects of pain on concomitant cognitive processes. In this fMRI study we examined the behavioral and neural effects of trigeminal (forehead) and peripheral (hand) pain on visual processing and memory encoding. Cerebral activity was measured in 23 healthy subjects performing a visual categorization task that was immediately followed by a surprise recognition task. During the categorization task subjects received concomitant noxious electrical stimulation on the forehead or hand. Our data show that fear ratings were significantly higher for trigeminal pain. Categorization and recognition performance did not differ between pictures that were presented with trigeminal and peripheral pain. However, object categorization in the presence of trigeminal pain was associated with stronger activity in task-relevant visual areas (lateral occipital complex, LOC), memory encoding areas (hippocampus and parahippocampus) and areas implicated in emotional processing (amygdala) compared to peripheral pain. Further, individual differences in neural activation between the trigeminal and the peripheral condition were positively related to differences in fear ratings between both conditions. Functional connectivity between amygdala and LOC was increased during trigeminal compared to peripheral painful stimulation. Fear-driven compensatory resource activation seems to be enhanced for trigeminal stimuli, presumably due to their exceptional biological relevance. Y1 - 2016 U6 - https://doi.org/10.1016/j.neuroimage.2016.03.026 SN - 1053-8119 VL - 134 SP - 386 EP - 395 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Chen, Bixia A1 - Schoemberg, Tobias A1 - Kraff, Oliver A1 - Dammann, Philipp A1 - Bitz, Andreas A1 - Schlamann, Marc A1 - Quick, Harald H. A1 - Ladd, Mark E. A1 - Sure, Ulrich A1 - Wrede, Karsten H. T1 - Cranial fixation plates in cerebral magnetic resonance imaging: a 3 and 7 Tesla in vivo image quality study JF - Magnetic Resonance Materials in Physics, Biology and Medicine N2 - Objective This study assesses and quantifies impairment of postoperative magnetic resonance imaging (MRI) at 7 Tesla (T) after implantation of titanium cranial fixation plates (CFPs) for neurosurgical bone flap fixation. Materials and methods The study group comprised five patients who were intra-individually examined with 3 and 7 T MRI preoperatively and postoperatively (within 72 h/3 months) after implantation of CFPs. Acquired sequences included T₁-weighted magnetization-prepared rapid-acquisition gradient-echo (MPRAGE), T₂-weighted turbo-spin-echo (TSE) imaging, and susceptibility-weighted imaging (SWI). Two experienced neurosurgeons and a neuroradiologist rated image quality and the presence of artifacts in consensus reading. Results Minor artifacts occurred around the CFPs in MPRAGE and T2 TSE at both field strengths, with no significant differences between 3 and 7 T. In SWI, artifacts were accentuated in the early postoperative scans at both field strengths due to intracranial air and hemorrhagic remnants. After resorption, the brain tissue directly adjacent to skull bone could still be assessed. Image quality after 3 months was equal to the preoperative examinations at 3 and 7 T. Conclusion Image quality after CFP implantation was not significantly impaired in 7 T MRI, and artifacts were comparable to those in 3 T MRI. Y1 - 2016 U6 - https://doi.org/10.1007/s10334-016-0548-1 SN - 1352-8661 VL - 29 IS - 3 SP - 389 EP - 398 PB - Springer CY - Berlin ER - TY - JOUR A1 - Orzada, Stephan A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - A method to approximate maximum local SAR in multichannel transmit MR systems without transmit phase information JF - Magnetic Resonance in Medicine N2 - Purpose To calculate local specific absorption rate (SAR) correctly, both the amplitude and phase of the signal in each transmit channel have to be known. In this work, we propose a method to derive a conservative upper bound for the local SAR, with a reasonable safety margin without knowledge of the transmit phases of the channels. Methods The proposed method uses virtual observation points (VOPs). Correction factors are calculated for each set of VOPs that prevent underestimation of local SAR when the VOPs are applied with the correct amplitudes but fixed phases. Results The proposed method proved to be superior to the worst-case calculation based on the maximum eigenvalue of the VOPs. The mean overestimation for six coil setups could be reduced, whereas no underestimation of the maximum local SAR occurred. In the best investigated case, the overestimation could be reduced from a factor of 3.3 to a factor of 1.7. Conclusion The upper bound for the local SAR calculated with the proposed method allows a fast estimation of the local SAR based on power measurements in the transmit channels and facilitates SAR monitoring in systems that do not have the capability to monitor transmit phases Y1 - 2016 U6 - https://doi.org/10.1002/mrm.26398 SN - 1522-2594 VL - 78 IS - 2 SP - 805 EP - 811 PB - International Society for Magnetic Resonance in Medicine ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus temperature limits JF - Medical Physics Y1 - 2017 U6 - https://doi.org/10.1002/mp.12034 N1 - This article is corrected by: Errata: Erratum: “RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus tissue temperature limits” [Med. Phys. 44(1), 143–157 (2017)] Volume 44, Issue 2, 772 VL - 44 IS - 1 SP - 143 EP - 157 ER - TY - JOUR A1 - Noureddine, Yacine A1 - Kraff, Oliver A1 - Ladd, Mark E. A1 - Wrede, Karsten H. A1 - Chen, Bixia A1 - Quick, Harald H. A1 - Schaefers, Gregor A1 - Bitz, Andreas T1 - In vitro and in silico assessment of RF-induced heating around intracranial aneurysm clips at 7 Tesla JF - Magnetic Resonance in Medicine Y1 - 2017 U6 - https://doi.org/10.1002/mrm.26650 SN - 1522-2594 IS - Early view PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - SAR Simulations & Safety JF - NeuroImage Y1 - 2017 U6 - https://doi.org/10.1016/j.neuroimage.2017.03.035 SN - 1053-8119 IS - Epub ahead of print PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Lind, Thorsten Patric T1 - Rückzahlung von gewinnunabhängigen Ausschüttungen bei Auflösung einer stillen Gesellschaft : BGH, Versäumnisurteil vom 20.09.2016 - II ZR 120/15 (LG Berlin) : Anmerkung JF - Fachdienst Zivilrecht - LMK : kommentierte BGH-Rechtsprechung ; in Zsarb. mit der Neuen Juristischen Wochenschrift / Lindermaier-Möhring N2 - Zum Zweck der Kapitalanlage beteiligte sich der Bekl. an einer Publikumsgesellschaft. Diese war als (mehrgliedrige) atypische stille Gesellschaft organisiert (vgl. a. BGHZ 199, 104 = DNotZ 2014, 374 = NZG 2013, 1422 = DStR 2014, 45 Rn. 18). Der Gesellschaftsvertrag („GV“) sah für diejenigen Gesellschafter, die wie der Bekl. ihre Einlage in Form einer Einmaleinlage erbracht hatten, eine jährliche gewinnunabhängige Ausschüttung vor. Es sollte sich dabei ausdrücklich nicht um eine Garantieverzinsung handeln. Ende 2009 wurde die stille Gesellschaft durch Mehrheitsbeschluss der Stillen aufgelöst. Nach dem GV waren die Stillen im Falle ihres Ausscheidens sowie bei „Liquidation des Unternehmens“ des Geschäftsinhabers verhältnismäßig an dem jeweils seit ihrem Beitritt gebildeten Vermögen einschließlich der stillen Reserven sowie eines evtl. Geschäftswerts zu beteiligen (Auseinandersetzungswert). Den sich hiernach für den Bekl. auf seinem Kapitalkonto ergebenden Negativsaldo sollte dieser durch Erstattung der von ihm erhaltenen gewinnunabhängigen Auszahlungen ausgleichen. Anders als das LG als Berufungsinstanz bejahte der BGH auf Grundlage des GV einen Rückerstattungsanspruch der klagenden Geschäftsinhaberin. Y1 - 2016 PB - Beck CY - München ER - TY - JOUR A1 - Damm, Marc André A1 - Sauerborn, Markus A1 - Fend, Thomas A1 - Herrmann, Ulf T1 - Optimisation of a urea selective catalytic reduction system with a coated ceramic mixing element JF - Journal of ceramic science and technology Y1 - 2017 SN - 2190-9385 (Print) U6 - https://doi.org/10.4416/JCST2016-00056 SN - 2190-9385 (Online) VL - 8 IS - 1 SP - 19 EP - 24 PB - Göller CY - Baden-Baden ER - TY - JOUR A1 - Lanzl, I. A1 - Kotliar, Konstantin T1 - Können Anti-VEGF-Injektionen Glaukom oder okuläre Hypertension verursachen? T1 - Can Anti-VEGF Injections Cause Glaucoma or Ocular Hypertension? JF - Klinische Monatsblätter für Augenheilkunde Y1 - 2017 U6 - https://doi.org/10.1055/s-0043-101819 SN - 0023-2165 VL - 234 IS - 2 SP - 191 EP - 193 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Enning, Manfred T1 - Vom "König der Landstraße" zur "Ameise 4.0" JF - ETR - Eisenbahntechnische Rundschau N2 - Auf Eisenbahn- und Logistikkonferenzen werden gelegentlich Videos von Blattschneiderameisen gezeigt, die effizient und selbstorganisiert große Mengen Material durch den Dschungel transportieren. Daran sollen wir uns ein Beispiel nehmen. Y1 - 2017 SN - 0013-2845 VL - 66 IS - 1/2 SP - 3 PB - DVV Media Group CY - Hamburg ER - TY - JOUR A1 - Enning, Manfred A1 - Pfaff, Raphael T1 - Güterwagen 4.0 - Der Güterwagen für das Internet der Dinge. Teil 1: Gesamtsystembetrachtung und grundlegendes Konzept JF - ETR - Eisenbahntechnische Rundschau Y1 - 2017 SN - 0013-2845 VL - 66 IS - 1/2 SP - 12 EP - 16 PB - DVV Media Group CY - Hamburg ER - TY - JOUR A1 - Honarvarfard, Elham A1 - Gamella, Maria A1 - Channaveerappa, Devika A1 - Darie, Costel C. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Katz, Evgeny T1 - Electrochemically Stimulated Insulin Release from a Modified Graphene–functionalized Carbon Fiber Electrode JF - Electroanalysis N2 - A graphene-functionalized carbon fiber electrode was modified with adsorbed polyethylenimine to introduce amino functionalities and then with trigonelline and 4-carboxyphenylboronic acid covalently bound to the amino groups. The trigonelline species containing quarterized pyridine groups produced positive charge on the electrode surface regardless of the pH value, while the phenylboronic acid species were neutral below pH 8 and negatively charged above pH 9 (note that their pKa=8.4). The total charge on the monolayer-modified electrode was positive at the neutral pH and negative at pH > 9. Note that 4-carboxyphenylboronic acid was attached to the electrode surface in molar excess to trigonelline, thus allowing the negative charge to dominate on the electrode surface at basic pH. Negatively charged fluorescent dye-labeled insulin (insulin-FITC) was loaded on the modified electrode surface at pH 7.0 due to its electrostatic attraction to the positively charged interface. The local pH in close vicinity to the electrode surface was increased to ca. 9–10 due to consumption of H+ ions upon electrochemical reduction of oxygen proceeding at the potential of −1.0 V (vs. Ag/AgCl) applied on the modified electrode. The process resulted in recharging of the electrode surface to the negative value due to the formation of the negative charge on the phenylboronic acid groups, thus resulting in the electrostatic repulsion of insulin-FITC and stimulating its release from the electrode surface. The insulin release was characterized by fluorescence spectroscopy (using the FITC-labeled insulin), by electrochemical measurements on an iridium oxide, IrOx, electrode and by mass spectrometry. The graphene-functionalized carbon fiber electrode demonstrated significant advantages in the signal-stimulated insulin release comparing with the carbon fiber electrode without the graphene species. Y1 - 2017 U6 - https://doi.org/10.1002/elan.201700095 SN - 1521-4109 VL - 29 IS - 6 SP - 1543 EP - 1553 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Zange, Jochen A1 - Schopen, Kathrin A1 - Albracht, Kirsten A1 - Gerlach, Darius A. A1 - Frings-Meuthen, Petra A1 - Maffiuletti, Nicola A. A1 - Bloch, Wilhelm A1 - Rittweger, Jörn T1 - Using the Hephaistos orthotic device to study countermeasure effectiveness of neuromuscular electrical stimulation and dietary lupin protein supplementation, a randomised controlled trial JF - Plos one Y1 - 2017 U6 - https://doi.org/10.1371/journal.pone.0171562 VL - 12 IS - 2 ER - TY - JOUR A1 - Kolditz, Melanie A1 - Albin, Thivaharan A1 - Brüggemann, Gert-Peter A1 - Abel, Dirk A1 - Albracht, Kirsten T1 - Robotergestütztes System für ein verbessertes neuromuskuläres Aufbautraining der Beinstrecker JF - at - Automatisierungstechnik N2 - Neuromuskuläres Aufbautraining der Beinstrecker ist ein wichtiger Bestandteil in der Rehabilitation und Prävention von Muskel-Skelett-Erkrankungen. Effektives Training erfordert hohe Muskelkräfte, die gleichzeitig hohe Belastungen von bereits geschädigten Strukturen bedeuten. Um trainingsinduzierte Schädigungen zu vermeiden, müssen diese Kräfte kontrolliert werden. Mit heutigen Trainingsgeräten können diese Ziele allerdings nicht erreicht werden. Für ein sicheres und effektives Training sollen durch den Einsatz der Robotik, Sensorik, eines Regelkreises sowie Muskel-Skelett-Modellen Belastungen am Zielgewebe direkt berechnet und kontrolliert werden. Auf Basis zweier Vorstudien zu möglichen Stellgrößen wird der Aufbau eines robotischen Systems vorgestellt, das sowohl für Forschungszwecke als auch zur Entwicklung neuartiger Trainingsgeräte verwendet werden kann. Y1 - 2016 U6 - https://doi.org/10.1515/auto-2016-0044 SN - 2196-677X VL - 64 IS - 11 SP - 905 EP - 914 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Hackl, Michael A1 - Wegmann, Kilian A1 - Kahmann, Stephanie Lucina A1 - Heinze, Nicolai A1 - Staat, Manfred A1 - Neiss, Wolfram F. A1 - Scaal, Martin A1 - Müller, Lars P. T1 - Radial shortening osteotomy reduces radiocapitellar contact pressures while preserving valgus stability of the elbow JF - Knee Surgery, Sports Traumatology, Arthroscopy Y1 - 2017 U6 - https://doi.org/10.1007/s00167-017-4468-z SN - 1433-7347 VL - 25 IS - 7 SP - 2280 EP - 2288 PB - Springer CY - Berlin ER - TY - JOUR A1 - Ferrein, Alexander A1 - Steinbauer, Gerald T1 - 20 Years of RoboCup - A Subjective Retrospection JF - KI - Künstliche Intelligenz N2 - This summer, RoboCup competitions were held for the 20th time in Leipzig, Germany. It was the second time that RoboCup took place in Germany, 10 years after the 2006 RoboCup in Bremen. In this article, we give an overview on the latest developments of RoboCup and what happened in the different leagues over the last decade. With its 20th edition, RoboCup clearly is a success story and a role model for robotics competitions. From our personal view point, we acknowledge this by giving a retrospection about what makes RoboCup such a success. Y1 - 2016 U6 - https://doi.org/10.1007/s13218-016-0449-5 SN - 1610-1987 VL - 30 IS - 3 SP - 225 EP - 232 PB - Springer CY - Berlin ER - TY - JOUR A1 - Reger, V. A1 - Döring, Bernd A1 - Kuhnhenne, M. T1 - Passive und aktive Maßnahmen zur Flächenkühlung im Stahl(leicht)bau JF - Bauingenieur N2 - Mit steigenden Dämmstandards und höheren Komfortanforderungen der Nutzer gerät die Problematik der sommerlichen Überhitzung zunehmend in den Fokus. Um die Überhitzung möglichst gering zu halten, sind Maßnahmen und Lösungen zu entwickeln, die den potenziellen Kühlbedarf eines Gebäudes vermeiden sowie reduzieren. Im Rahmen des europäischen Forschungsprojektes BATIMASS wurden Techniken untersucht, die die sommerliche Raumtemperatur ohne zusätzliche Kühlung (passiv) oder aber mit energieeffizienter wasserbasierter Flächenkühlung (aktiv) reduzieren und die besonders für Gebäude in Stahl(leicht)bauweise geeignet sind. Dafür wurde die Methodik der thermisch äquivalenten Decke weiterentwickelt, um das thermische Verhalten von Profilblechdecken in Gebäuden für beide Lösungsansätze analysieren zu können. Darüber hinaus wurde der Einsatz von Phasenwechselmaterial (PCM) zur Steigerung der Speicherfähigkeit von leichten Decken mit besonders geringer thermischer Masse in Simulationen sowie im Labor untersucht und bewertet. Y1 - 2016 U6 - https://doi.org/10.37544/0005-6650-2016-07-08-63 SN - 0005-6650 N1 - gedruckt in der Bereichsbibliothek Bayernallee unter der Signatur 13 Z 049 VL - 91 IS - Jul/Aug SP - 309 EP - 316 PB - VDI Fachmedien CY - Düsseldorf ER - TY - JOUR A1 - Neu, Eugen A1 - Janser, Frank A1 - Khatibi, Akbar A. A1 - Orifici, Adrian C. T1 - Fully Automated Operational Modal Analysis using multi-stage clustering JF - Mechanical Systems and Signal Processing Y1 - 2017 U6 - https://doi.org/10.1016/j.ymssp.2016.07.031 SN - 0888-3270 VL - Vol. 84, Part A SP - 308 EP - 323 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Wrede, Oliver T1 - Continuity in travel information JF - Information Design Journal N2 - This article discusses the contrast between the information transportation companies provide to travellers and that of their brand messaging. Companies’ brand messaging often portrays the service they provide as pleasant, stress free and perfect. Customers and users of the service, on the other hand, often describe their experience of the service as a negative one. This article suggests that the brand value would be greater if transportation companies paid more attention to the users’ experience when designing their information systems, particularly in worst case scenarios. Y1 - 2016 U6 - https://doi.org/10.1075/idj.22.2.09wre SN - 0142-5471 N1 - Gedruckt vorhanden in der Bereichsbibliothek Boxgraben unter 53 Z 971-2016 (Magazin) VL - 22 IS - 2 SP - 172 EP - 178 PB - John Benjamins CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Werner, Frederik A1 - Buniatyan, V. V. A1 - Wagner, Torsten A1 - Miamoto, K. A1 - Yoshinobu, T. A1 - Schöning, Michael Josef T1 - Towards addressability of light-addressable potentiometric sensors: Shunting effect of non-illuminated region and cross-talk JF - Sensor and Actuators B: Chemical N2 - The LAPS (light-addressable potentiometric sensor) platform is one of the most attractive approaches for chemical and biological sensing with many applications ranging from pH and ion/analyte concentration measurements up to cell metabolism detection and chemical imaging. However, although it is generally accepted that LAPS measurements are spatially resolved, the light-addressability feature of LAPS devices has not been discussed in detail so far. In this work, an extended electrical equivalent-circuit model of the LAPS has been presented, which takes into account possible cross-talk effects due to the capacitive coupling of the non-illuminated region. A shunting effect of the non-illuminated area on the measured photocurrent and addressability of LAPS devices has been studied. It has been shown, that the measured photocurrent will be determined not only by the local interfacial potential in the illuminated region but also by possible interfacial potential changes in the non-illuminated region, yielding cross-talk effects. These findings were supported by the experimental investigations of a penicillin-sensitive multi-spot LAPS and a metal-insulator-semiconductor LAPS as model systems. Y1 - 2017 U6 - https://doi.org/10.1016/j.snb.2017.01.047 SN - 0925-4005 IS - 244 SP - 1071 EP - 1079 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jahnke, Siegfried A1 - Roussel, Johanna A1 - Hombach, Thomas A1 - Kochs, Johannes A1 - Fischbach, Andreas A1 - Huber, Gregor A1 - Scharr, Hanno T1 - phenoSeeder - A robot system for automated handling and phenotyping of individual seeds JF - Plant physiology N2 - The enormous diversity of seed traits is an intriguing feature and critical for the overwhelming success of higher plants. In particular, seed mass is generally regarded to be key for seedling development but is mostly approximated by using scanning methods delivering only two-dimensional data, often termed seed size. However, three-dimensional traits, such as the volume or mass of single seeds, are very rarely determined in routine measurements. Here, we introduce a device named phenoSeeder, which enables the handling and phenotyping of individual seeds of very different sizes. The system consists of a pick-and-place robot and a modular setup of sensors that can be versatilely extended. Basic biometric traits detected for individual seeds are two-dimensional data from projections, three-dimensional data from volumetric measures, and mass, from which seed density is also calculated. Each seed is tracked by an identifier and, after phenotyping, can be planted, sorted, or individually stored for further evaluation or processing (e.g. in routine seed-to-plant tracking pipelines). By investigating seeds of Arabidopsis (Arabidopsis thaliana), rapeseed (Brassica napus), and barley (Hordeum vulgare), we observed that, even for apparently round-shaped seeds of rapeseed, correlations between the projected area and the mass of seeds were much weaker than between volume and mass. This indicates that simple projections may not deliver good proxies for seed mass. Although throughput is limited, we expect that automated seed phenotyping on a single-seed basis can contribute valuable information for applications in a wide range of wild or crop species, including seed classification, seed sorting, and assessment of seed quality. Y1 - 2016 U6 - https://doi.org/10.1104/pp.16.01122 SN - 0032-0889 VL - 172 IS - 3 SP - 1358 EP - 1370 PB - Oxford University Press CY - Oxford ER - TY - JOUR A1 - Neu, Eugen A1 - Janser, Frank A1 - Khatibi, Akbar A. A1 - Orifici, Adrian C. T1 - Automated modal parameter-based anomaly detection under varying wind excitation JF - Structural Health Monitoring N2 - Wind-induced operational variability is one of the major challenges for structural health monitoring of slender engineering structures like aircraft wings or wind turbine blades. Damage sensitive features often show an even bigger sensitivity to operational variability. In this study a composite cantilever was subjected to multiple mass configurations, velocities and angles of attack in a controlled wind tunnel environment. A small-scale impact damage was introduced to the specimen and the structural response measurements were repeated. The proposed damage detection methodology is based on automated operational modal analysis. A novel baseline preparation procedure is described that reduces the amount of user interaction to the provision of a single consistency threshold. The procedure starts with an indeterminate number of operational modal analysis identifications from a large number of datasets and returns a complete baseline matrix of natural frequencies and damping ratios that is suitable for subsequent anomaly detection. Mahalanobis distance-based anomaly detection is then applied to successfully detect the damage under varying severities of operational variability and with various degrees of knowledge about the present operational conditions. The damage detection capabilities of the proposed methodology were found to be excellent under varying velocities and angles of attack. Damage detection was less successful under joint mass and wind variability but could be significantly improved through the provision of the currently encountered operational conditions. Y1 - 2016 U6 - https://doi.org/10.1177/1475921716665803 SN - 1475-9217 VL - 15 IS - 6 SP - 1 EP - 20 PB - Sage CY - London ER - TY - JOUR A1 - Katz, Evgeny A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Enzyme-based logic gates and circuits - analytical applications and interfacing with electronics JF - Analytical and Bioanalytical Chemistry N2 - The paper is an overview of enzyme-based logic gates and their short circuits, with specific examples of Boolean AND and OR gates, and concatenated logic gates composed of multi-step enzyme-biocatalyzed reactions. Noise formation in the biocatalytic reactions and its decrease by adding a “filter” system, converting convex to sigmoid response function, are discussed. Despite the fact that the enzyme-based logic gates are primarily considered as components of future biomolecular computing systems, their biosensing applications are promising for immediate practical use. Analytical use of the enzyme logic systems in biomedical and forensic applications is discussed and exemplified with the logic analysis of biomarkers of various injuries, e.g., liver injury, and with analysis of biomarkers characteristic of different ethnicity found in blood samples on a crime scene. Interfacing of enzyme logic systems with modified electrodes and semiconductor devices is discussed, giving particular attention to the interfaces functionalized with signal-responsive materials. Future perspectives in the design of the biomolecular logic systems and their applications are discussed in the conclusion. Y1 - 2017 U6 - https://doi.org/10.1007/s00216-016-0079-7 SN - 1618-2650 VL - 409 SP - 81 EP - 94 PB - Springer CY - Berlin ER - TY - JOUR A1 - Alexopoulos, Spiros A1 - Hoffschmidt, Bernhard T1 - Advances in solar tower technology JF - Wiley interdisciplinary reviews : Energy and Environment : WIREs Y1 - 2017 U6 - https://doi.org/10.1002/wene.217 SN - 2041-840X VL - 6 IS - 1 SP - 1 EP - 19 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Laack, Walter van T1 - Neurophysiologisch ist das nicht alles zu erklären : Nahtoderfahrungen aus wissenschaftlicher Sicht JF - Der Allgemeinarzt Y1 - 2017 SN - 0172-7249 VL - 38 IS - 1 SP - 4 EP - 7 PB - Universimed Deutschland GmbH CY - Mainz ER - TY - JOUR A1 - Thomas, Axel T1 - Genussrechte als Instrument der Unternehmensfinanzierung von kommunalen Wohnungs- baugesellschaften JF - VM Verwaltung und Management N2 - Die kommunalen Wohnungsbaugesellschaften und ihr Geschäftszweck bzw. Versorgungsauftrag erfahren aus gesamtgesellschaftlichen Gründen aktuell einen erheblichen Bedeutungszuwachs. Der kommunale Wohnungsbau soll und muss intensiviert werden, da z.B. zunehmend Wohnungsbindungen auslaufen. Bezahlbare Neubauten fehlen speziell Familien, Senioren, Studenten und Flüchtlingen. Um das Investitionsvolumen zu bewältigen, bedarf es nicht nur der Förderkredite, sondern auch der Zuführung „frischen Kapitals“. Der Beitrag stellt dar, dass Genussrechte ein interessantes und oft unbekanntes Finanzierungsinstrument für kommunale Wohnungsbaugesellschaften mit passgenauen Ausgestaltungsmöglichkeiten sind. Mit Hilfe von Genussrechten können die notwendigen Neubau-Investitionen solide mit Quasi-Eigenkapital unterlegt werden und den sozialen Wohnungsbau wiederbeleben. Genussrechte als Hybridkapital lassen sich mangels gesetzlicher Eingrenzung exakt und individuell ebenso an die Bedürfnisse der kommunalen Wohnungsbaugesellschaft anpassen wie an die der Gesellschafter und des jeweiligen Neubauvorhabens. Y1 - 2016 U6 - https://doi.org/10.5771/0947-9856-2016-6-322 SN - 0947-9856 VL - 22 IS - 6 SP - 322 EP - 327 PB - Nomos CY - Baden-Baden ER - TY - JOUR A1 - Funke, Harald A1 - Beckmann, Nils A1 - Keinz, Jan A1 - Abanteriba, Sylvester T1 - Comparison of Numerical Combustion Models for Hydrogen and Hydrogen-Rich Syngas Applied for Dry-Low-NOx-Micromix-Combustion JF - ASME Turbo Expo 2016: Turbomachinery Technical Conference and Exposition Volume 4A: Combustion, Fuels and Emissions Seoul, South Korea, June 13–17, 2016 N2 - The Dry-Low-NOₓ (DLN) Micromix combustion technology has been developed as low emission combustion principle for industrial gas turbines fueled with hydrogen or syngas. The combustion process is based on the phenomenon of jet-in-crossflow-mixing. Fuel is injected perpendicular into the air-cross-flow and burned in a multitude of miniaturized, diffusion-like flames. The miniaturization of the flames leads to a significant reduction of NOₓ emissions due to the very short residence time of reactants in the flame. In the Micromix research approach, CFD analyses are validated towards experimental results. The combination of numerical and experimental methods allows an efficient design and optimization of DLN Micromix combustors concerning combustion stability and low NOₓ emissions. The paper presents a comparison of several numerical combustion models for hydrogen and hydrogen-rich syngas. They differ in the complexity of the underlying reaction mechanism and the associated computational effort. For pure hydrogen combustion a one-step global reaction is applied using a hybrid Eddy-Break-up model that incorporates finite rate kinetics. The model is evaluated and compared to a detailed hydrogen combustion mechanism derived by Li et al. including 9 species and 19 reversible elementary reactions. Based on this mechanism, reduction of the computational effort is achieved by applying the Flamelet Generated Manifolds (FGM) method while the accuracy of the detailed reaction scheme is maintained. For hydrogen-rich syngas combustion (H₂-CO) numerical analyses based on a skeletal H₂/CO reaction mechanism derived by Hawkes et al. and a detailed reaction mechanism provided by Ranzi et al. are performed. The comparison between combustion models and the validation of numerical results is based on exhaust gas compositions available from experimental investigation on DLN Micromix combustors. The conducted evaluation confirms that the applied detailed combustion mechanisms are able to predict the general physics of the DLN-Micromix combustion process accurately. The Flamelet Generated Manifolds method proved to be generally suitable to reduce the computational effort while maintaining the accuracy of detailed chemistry. Especially for reaction mechanisms with a high number of species accuracy and computational effort can be balanced using the FGM model. Y1 - 2016 SN - 978-0-7918-4975-0 U6 - https://doi.org/10.1115/GT2016-56430 PB - ASME CY - New York, NY ER - TY - JOUR A1 - Ayed, Anis Haj A1 - Kusterer, Karsten A1 - Funke, Harald A1 - Keinz, Jan T1 - CFD Based Improvement of the DLN Hydrogen Micromix Combustion Technology at Increased Energy Densities JF - American Scientific Research Journal for Engineering, Technology, and Sciences (ASRJETS) N2 - Combined with the use of renewable energy sources for its production, Hydrogen represents a possible alternative gas turbine fuel within future low emission power generation. Due to the large difference in the physical properties of Hydrogen compared to other fuels such as natural gas, well established gas turbine combustion systems cannot be directly applied for Dry Low NOx (DLN) Hydrogen combustion. Thus, the development of DLN combustion technologies is an essential and challenging task for the future of Hydrogen fuelled gas turbines. The DLN Micromix combustion principle for hydrogen fuel has been developed to significantly reduce NOx-emissions. This combustion principle is based on cross-flow mixing of air and gaseous hydrogen which reacts in multiple miniaturized diffusion-type flames. The major advantages of this combustion principle are the inherent safety against flash-back and the low NOx-emissions due to a very short residence time of reactants in the flame region of the micro-flames. The Micromix Combustion technology has been already proven experimentally and numerically for pure Hydrogen fuel operation at different energy density levels. The aim of the present study is to analyze the influence of different geometry parameter variations on the flame structure and the NOx emission and to identify the most relevant design parameters, aiming to provide a physical understanding of the Micromix flame sensitivity to the burner design and identify further optimization potential of this innovative combustion technology while increasing its energy density and making it mature enough for real gas turbine application. The study reveals great optimization potential of the Micromix Combustion technology with respect to the DLN characteristics and gives insight into the impact of geometry modifications on flame structure and NOx emission. This allows to further increase the energy density of the Micromix burners and to integrate this technology in industrial gas turbines. Y1 - 2016 SN - 2313-4402 VL - 26 IS - 3 SP - 290 EP - 303 PB - GSSRR ER - TY - JOUR A1 - Funke, Harald A1 - Keinz, Jan A1 - Kusterer, Karsten A1 - Ayed, Anis Haj A1 - Kazari, Masahide A1 - Kitajima, Junichi A1 - Horikawa, Atsushi A1 - Okada, Kunio T1 - Experimental and Numerical Study on Optimizing the Dry Low NOₓ Micromix Hydrogen Combustion Principle for Industrial Gas Turbine Applications JF - Journal of Thermal Science and Engineering Applications N2 - Combined with the use of renewable energy sources for its production, hydrogen represents a possible alternative gas turbine fuel for future low-emission power generation. Due to the difference in the physical properties of hydrogen compared to other fuels such as natural gas, well-established gas turbine combustion systems cannot be directly applied to dry low NOₓ (DLN) hydrogen combustion. The DLN micromix combustion of hydrogen has been under development for many years, since it has the promise to significantly reduce NOₓ emissions. This combustion principle for air-breathing engines is based on crossflow mixing of air and gaseous hydrogen. Air and hydrogen react in multiple miniaturized diffusion-type flames with an inherent safety against flashback and with low NOₓ emissions due to a very short residence time of the reactants in the flame region. The paper presents an advanced DLN micromix hydrogen application. The experimental and numerical study shows a combustor configuration with a significantly reduced number of enlarged fuel injectors with high-thermal power output at constant energy density. Larger fuel injectors reduce manufacturing costs, are more robust and less sensitive to fuel contamination and blockage in industrial environments. The experimental and numerical results confirm the successful application of high-energy injectors, while the DLN micromix characteristics of the design point, under part-load conditions, and under off-design operation are maintained. Atmospheric test rig data on NOₓ emissions, optical flame-structure, and combustor material temperatures are compared to numerical simulations and show good agreement. The impact of the applied scaling and design laws on the miniaturized micromix flamelets is particularly investigated numerically for the resulting flow field, the flame-structure, and NOₓ formation. Y1 - 2016 U6 - https://doi.org/10.1115/1.4034849 SN - 1948-5093 N1 - TSEA-15-1227 VL - 9 IS - 2 SP - 021001 EP - 021001-10 PB - ASME CY - New York, NY ER - TY - JOUR A1 - Wollert, Jörg T1 - OS-Funktionalität ohne OS für das IoT JF - Design & Elektronik N2 - Low-end-Embedded-Plattformen stellen eine hohe Anforderung an die Entscheidungsfähigkeit des Entwicklers: Zum nächstgrößeren Prozessor greifen und ein Betriebssystem benutzen oder doch besser auf das Betriebssystem verzichten? Die Frage lässt sich einfach beantworten: Einen Nanokernel verwenden und das Embedded-System mit einem minimalen Footprint realisieren. Adam Dunkels Protothreads sind eine ausgesprochen effiziente Art, Mikrocontroller gut strukturiert zu programmieren und gleichzeitig auf Overhead zu verzichten. So können auch mit kleinen 8-bit-Prozessoren anspruchsvolle Aufgaben in einem Thread-Modell bearbeitet werden. Man muss also nicht immer das Rad neu erfinden oder gleich auf Linux-basierte Systeme zurückgreifen. KW - Designpraxis KW - Minimal-Ansatz für Embedded-Systeme Y1 - 2016 SN - 0933-8667 IS - 11 SP - 85 EP - 90 PB - WEKA-Fachmedien CY - München ER - TY - JOUR A1 - Bung, Daniel Bernhard A1 - Valero, Daniel T1 - Optical flow estimation in aerated flows JF - Journal of Hydraulic Research N2 - Optical flow estimation is known from Computer Vision where it is used to determine obstacle movements through a sequence of images following an assumption of brightness conservation. This paper presents the first study on application of the optical flow method to aerated stepped spillway flows. For this purpose, the flow is captured with a high-speed camera and illuminated with a synchronized LED light source. The flow velocities, obtained using a basic Horn–Schunck method for estimation of the optical flow coupled with an image pyramid multi-resolution approach for image filtering, compare well with data from intrusive conductivity probe measurements. Application of the Horn–Schunck method yields densely populated flow field data sets with velocity information for every pixel. It is found that the image pyramid approach has the most significant effect on the accuracy compared to other image processing techniques. However, the final results show some dependency on the pixel intensity distribution, with better accuracy found for grey values between 100 and 150. Y1 - 2016 U6 - https://doi.org/10.1080/00221686.2016.1173600 VL - 54 IS - 5 SP - 575 EP - 580 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Wollert, Jörg A1 - Booke, Andreas T1 - IoT von der Stange JF - elektronik N2 - Heute sollte am besten jedes Gerät in die große Rechnerwolke eingebettet werden. Doch so einfach ist das nicht, denn Cloud ist viel mehr als nur das Internet der Dinge. Als Anwender muss man sich also fragen, welche Dienste man möchte und welchem Anbieter man sein Vertrauen schenkt. KW - Einbetten in das Internet der Dinge Y1 - 2016 IS - 21 (2016) SP - 30 EP - 37 PB - WEKA-Fachmedien CY - München ER - TY - JOUR A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios T1 - Influence of the mechanical properties of the muscle-tendon unit on force generation in runners with different running economy JF - Biological Cybernetics Y1 - 2006 U6 - https://doi.org/10.1007/s00422-006-0070-z SN - 1432-0770 VL - 95 IS - 1 SP - 87 EP - 96 ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Karamanidis, Kiros A1 - Albracht, Kirsten T1 - Adaptational responses of the human Achilles tendon by modulation of the applied cyclic strain magnitude JF - Journal of Experimental Biology Y1 - 2007 U6 - https://doi.org/10.1242/jeb.003814 SN - 0022-0949 VL - 210 IS - 15 SP - 2743 EP - 2753 ER - TY - JOUR A1 - Albracht, Kirsten A1 - Arampatzis, A. A1 - Baltzopoulos, V. T1 - Assessment of muscle volume and physiological cross-sectional area of the human triceps surae muscle in vivo JF - Journal of Biomechanics Y1 - 2008 U6 - https://doi.org/10.1016/j.jbiomech.2008.04.020 SN - 0021-9290 VL - 41 SP - 2211 EP - 2218 ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Karamanidis, Kiros A1 - Mademli, Lida A1 - Albracht, Kirsten T1 - Plasticity of the human tendon to short and long-term mechanical loading JF - Exercise and Sport Sciences Reviews Y1 - 2009 U6 - https://doi.org/10.1097/JES.0b013e31819c2e1d SN - 1538-3008 VL - 37 IS - 2 SP - 66 EP - 72 ER - TY - JOUR A1 - Aggeloussis, Nickos A1 - Giannakou, Erasmia A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios T1 - Reproducibility of fascicle length and pennation angle of gastrocnemius medialis in human gait in vivo JF - Gait and Posture N2 - The purpose of the current study was to examine the reproducibility of fascicle length and pennation angle of gastrocnemius medialis while human walking. To the best of our knowledge, this is the first study of the reproducibility of fascicle length and pennation angle of gastrocnemius medialis in vivo during human gait. Twelve males performed 10 gait trials on a treadmill, in 2 separate days. B-mode ultrasonography, with the ultrasound probe firmly adjusted in the transverse and frontal planes using a special cast, was used to measure the fascicle length and the pennation angle of the gastrocnemius medialis (GM). A Vicon 624 system with three cameras operating at 120 Hz was also used to record the ankle and knee joint angles. The results showed that measurements of fascicle length and pennation angle showed high reproducibility during the gait cycle, both within the same day and between different days. Moreover, the root mean square differences between the repeated waveforms of both variables were very small, compared with their ranges (fascicle length: RMS = ∼3 mm, range: 38–63 mm; pennation angle: RMS = ∼1.5°, range: 22–32°). However, their reproducibility was lower compared to the joint angles. It was found that representative data have to be derived by a wide number of gait trials (fascicle length ∼six trials, pennation angle more than 10 trials), to assure the reliability of the fascicle length and pennation angle in human gait. Y1 - 2010 U6 - https://doi.org/10.1016/j.gaitpost.2009.08.249 SN - 0966-6362 VL - 31 IS - 1 SP - 73 EP - 77 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Peper, Andreas A1 - Bierbaum, Stefanie A1 - Albracht, Kirsten T1 - Plasticity of human Achilles tendon mechanical and morphological properties in response to cyclic strain JF - Journal of Biomechanics N2 - The purpose of the current study in combination with our previous published data (Arampatzis et al., 2007) was to examine the effects of a controlled modulation of strain magnitude and strain frequency applied to the Achilles tendon on the plasticity of tendon mechanical and morphological properties. Eleven male adults (23.9±2.2 yr) participated in the study. The participants exercised one leg at low magnitude tendon strain (2.97±0.47%), and the other leg at high tendon strain magnitude (4.72±1.08%) of similar frequency (0.5 Hz, 1 s loading, 1 s relaxation) and exercise volume (integral of the plantar flexion moment over time) for 14 weeks, 4 days per week, 5 sets per session. The exercise volume was similar to the intervention of our earlier study (0.17 Hz frequency; 3 s loading, 3 s relaxation) allowing a direct comparison of the results. Before and after the intervention ankle joint moment has been measured by a dynamometer, tendon–aponeurosis elongation by ultrasound and cross-sectional area of the Achilles tendon by magnet resonance images (MRI). We found a decrease in strain at a given tendon force, an increase in tendon–aponeurosis stiffness and tendon elastic modulus of the Achilles tendon only in the leg exercised at high strain magnitude. The cross-sectional area (CSA) of the Achilles tendon did not show any statistically significant (P>0.05) differences to the pre-exercise values in both legs. The results indicate a superior improvement in tendon properties (stiffness, elastic modulus and CSA) at the low frequency (0.17 Hz) compared to the high strain frequency (0.5 Hz) protocol. These findings provide evidence that the strain magnitude applied to the Achilles tendon should exceed the value, which occurs during habitual activities to trigger adaptational effects and that higher tendon strain duration per contraction leads to superior tendon adaptational responses. Y1 - 2010 U6 - https://doi.org/10.1016/j.jbiomech.2010.08.014 SN - 0021-9290 VL - 43 IS - 16 SP - 3073 EP - 3079 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Karamanidis, Kiros A1 - Albracht, Kirsten A1 - Braunstein, Bjoern A1 - Catala, Maria Moreno A1 - Goldmann, Jan-Peter A1 - Brüggemann, Gert-Peter T1 - Lower leg musculoskeletal geometry and sprint performance JF - Gait and Posture N2 - The purpose of this study was to investigate whether sprint performance is related to lower leg musculoskeletal geometry within a homogeneous group of highly trained 100-m sprinters. Using a cluster analysis, eighteen male sprinters were divided into two groups based on their personal best (fast: N = 11, 10.30 ± 0.07 s; slow: N = 7, 10.70 ± 0.08 s). Calf muscular fascicle arrangement and Achilles tendon moment arms (calculated by the gradient of tendon excursion versus ankle joint angle) were analyzed for each athlete using ultrasonography. Achilles tendon moment arm, foot and ankle skeletal geometry, fascicle arrangement as well as the ratio of fascicle length to Achilles tendon moment arm showed no significant (p > 0.05) correlation with sprint performance, nor were there any differences in the analyzed musculoskeletal parameters between the fast and slow sprinter group. Our findings provide evidence that differences in sprint ability in world-class athletes are not a result of differences in the geometrical design of the lower leg even when considering both skeletal and muscular components. Y1 - 2011 U6 - https://doi.org/10.1016/j.gaitpost.2011.03.009 SN - 0966-6362 VL - 34 IS - 1 SP - 138 EP - 141 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios T1 - Exercise-induced changes in triceps surae tendon stiffness and muscle strength affect running economy in humans JF - European Journal of Applied Physiology Y1 - 2013 U6 - https://doi.org/10.1007/s00421-012-2585-4 SN - 1439-6327 VL - 113 IS - 6 SP - 1605 EP - 1615 PB - Springer CY - Berlin ER - TY - JOUR A1 - Seynnes, O. R. A1 - Bojsen-Moller, J. A1 - Albracht, Kirsten A1 - Arndt, A. A1 - Cronin, N. J. A1 - Finni, T. A1 - Magnusson, S. P. T1 - Ultrasound-based testing of tendon mechanical properties: a critical evaluation JF - Journal of Applied Physiology Y1 - 2015 U6 - https://doi.org/10.1152/japplphysiol.00849.2014 SN - 8750-7587 VL - 118 IS - 2 SP - 133 EP - 141 ER - TY - JOUR A1 - Yang, Peng-Fei A1 - Kriechbaumer, Andreas A1 - Albracht, Kirsten A1 - Sanno, Maximilian A1 - Ganse, Bergita A1 - Koy, Timmo A1 - Shang, Peng A1 - Brüggemann, Gert-Peter A1 - Müller, Lars Peter A1 - Rittweger, Jörn T1 - On the relationship between tibia torsional deformation and regional muscle contractions in habitual human exercises in vivo JF - Journal of Biomechanics Y1 - 2015 U6 - https://doi.org/10.1016/j.jbiomech.2014.12.031 SN - 0021-9290 VL - 48 IS - 3 SP - 456 EP - 464 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Belavy, Daniel L. A1 - Albracht, Kirsten A1 - Bruggemann, Gert-Peter A1 - Vergroesen, Pieter-Paul A. A1 - Dieen, Jaap H. van T1 - Can exercise positively influence the intervertebral disc? JF - Sports Medicine N2 - To better understand what kinds of sports and exercise could be beneficial for the intervertebral disc (IVD), we performed a review to synthesise the literature on IVD adaptation with loading and exercise. The state of the literature did not permit a systematic review; therefore, we performed a narrative review. The majority of the available data come from cell or whole-disc loading models and animal exercise models. However, some studies have examined the impact of specific sports on IVD degeneration in humans and acute exercise on disc size. Based on the data available in the literature, loading types that are likely beneficial to the IVD are dynamic, axial, at slow to moderate movement speeds, and of a magnitude experienced in walking and jogging. Static loading, torsional loading, flexion with compression, rapid loading, high-impact loading and explosive tasks are likely detrimental for the IVD. Reduced physical activity and disuse appear to be detrimental for the IVD. We also consider the impact of genetics and the likelihood of a ‘critical period’ for the effect of exercise in IVD development. The current review summarises the literature to increase awareness amongst exercise, rehabilitation and ergonomic professionals regarding IVD health and provides recommendations on future directions in research. KW - Intradiscal Pressure KW - Annulus Fibrosus KW - Disc Degeneration KW - Nucleus Pulposus KW - Intervertebral Disc Y1 - 2016 U6 - https://doi.org/10.1007/s40279-015-0444-2 SN - 1179-2035 VL - 46 IS - 4 SP - 473 EP - 485 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kolditz, Melanie A1 - Albin, Thivaharan A1 - Abel, Dirk A1 - Fasse, Alessandro A1 - Brüggemann, Gert-Peter A1 - Albracht, Kirsten T1 - Evaluation of foot position and orientation as manipulated variables to control external knee adduction moments in leg extension training JF - Computer methods and programs in biomedicine N2 - Background and Objective Effective leg extension training at a leg press requires high forces, which need to be controlled to avoid training-induced damage. In order to avoid high external knee adduction moments, which are one reason for unphysiological loadings on knee joint structures, both training movements and the whole reaction force vector need to be observed. In this study, the applicability of lateral and medial changes in foot orientation and position as possible manipulated variables to control external knee adduction moments is investigated. As secondary parameters both the medio-lateral position of the center of pressure and the frontal-plane orientation of the reaction force vector are analyzed. Methods Knee adduction moments are estimated using a dynamic model of the musculoskeletal system together with the measured reaction force vector and the motion of the subject by solving the inverse kinematic and dynamic problem. Six different foot conditions with varying positions and orientations of the foot in a static leg press are evaluated and compared to a neutral foot position. Results Both lateral and medial wedges under the foot and medial and lateral shifts of the foot can influence external knee adduction moments in the presented study with six healthy subjects. Different effects are observed with the varying conditions: the pose of the leg is changed and the direction and center of pressure of the reaction force vector is influenced. Each effect results in a different direction or center of pressure of the reaction force vector. Conclusions The results allow the conclusion that foot position and orientation can be used as manipulated variables in a control loop to actively control knee adduction moments in leg extension training. KW - External knee adduction moments KW - Manipulated variables KW - Inverse dynamic problem KW - Inverse kinematic problem KW - Musculoskeletal model Y1 - 2016 U6 - https://doi.org/10.1016/j.cmpb.2016.09.005 SN - 0169-2607 N1 - Part of special issue: "SI: Personalised Models and System Identification" VL - 171 SP - 81 EP - 86 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ferrein, Alexander A1 - Schiffer, Stefan A1 - Booysen, T. A1 - Stopforth, R. T1 - Why it is harder to run RoboCup in South Africa: Experiences from German South African collaborations JF - International Journal of Advanced Robotic Systems N2 - Robots are widely used as a vehicle to spark interest in science and technology in learners. A number of initiatives focus on this issue, for instance, the Roberta Initiative, the FIRST Lego League, the World Robot Olympiad and RoboCup Junior. Robotic competitions are valuable not only for school learners but also for university students, as the RoboCup initiative shows. Besides technical skills, the students get some project exposure and experience what it means to finish their tasks on time. But qualifying students for future high-tech areas should not only be for students from developed countries. In this article, we present our experiences with research and education in robotics within the RoboCup initiative, in Germany and South Africa; we report on our experiences with trying to get the RoboCup initiative in South Africa going. RoboCup has a huge support base of academic institutions in Germany; this is not the case in South Africa. We present our ‘north–south’ collaboration initiatives in RoboCup between Germany and South Africa and discuss some of the reasons why we think it is harder to run RoboCup in South Africa. Y1 - 2016 U6 - https://doi.org/10.1177/1729881416662789 SN - 1729-8806 VL - 13 IS - 5 SP - 1 EP - 13 ER - TY - JOUR A1 - Staat, Manfred T1 - Limit and shakedown analysis under uncertainty JF - Tap chi Khoa hoc & ung dung - Dai hoc Ton Duc Thang Y1 - 2012 N1 - = Journal of Applied Sciences - Ton Duc Thang University VL - 19 SP - 45 EP - 47 ER - TY - JOUR A1 - Kilic, S. A. A1 - Raatschen, Hans-Jürgen A1 - Körfgen, B. A1 - Apaydin, N. M. A1 - Astaneh-Asl, A. T1 - FE Model of the Fatih Sultan Mehmet Suspension Bridge Using Thin Shell Finite Elements JF - Arabian Journal for Science and Engineering N2 - This paper presents the results of an eigenvalue analysis of the Fatih Sultan Mehmet Bridge. A high-resolution finite element model was created directly from the available design documents. All physical properties of the structural components were included in detail, so no calibration to the measured data was necessary. The deck and towers were modeled with shell elements. A nonlinear static analysis was performed before the eigenvalue calculation. The calculated natural frequencies and corresponding mode shapes showed good agreement with the available measured ambient vibration data. The calculation of the effective modal mass showed that nine modes had single contributions higher than 5 % of the total mass. They were in a frequency range up to 1.2 Hz. The comparison of the results for the torsional modes especially demonstrated the advantage of using thin shell finite elements over the beam modeling approach. KW - Suspension bridge KW - 3D nonlinear finite element model KW - Thin shell finite elements KW - Natural frequency KW - Effective modal mass Y1 - 2017 U6 - https://doi.org/10.1007/s13369-016-2316-y SN - 2191-4281 VL - 42 IS - 3 SP - 1103 EP - 1116 PB - Springer Nature ER - TY - JOUR A1 - Niedermeyer, Angela A1 - Zhou, Bei A1 - Dursun, Gözde A1 - Temiz Artmann, Aysegül A1 - Markert, Bernd T1 - An examination of tissue engineered scaffolds in a bioreactor JF - Proceedings in Applied Mathematics and Mechanics PAMM N2 - Replacement tissues, designed to fill in articular cartilage defects, should exhibit the same properties as the native material. The aim of this study is to foster the understanding of, firstly, the mechanical behavior of the material itself and, secondly, the influence of cultivation parameters on cell seeded implants as well as on cell migration into acellular implants. In this study, acellular cartilage replacement material is theoretically, numerically and experimentally investigated regarding its viscoelastic properties, where a phenomenological model for practical applications is developed. Furthermore, remodeling and cell migration are investigated. Y1 - 2016 U6 - https://doi.org/10.1002/pamm.201610038 SN - 1617-7061 N1 - Joint Annual Meeting of DMV and GAMM 2016, 87th Annual Meeting of the International Association of Applied Mathematics and Mechanics (GAMM) and Deutsche Mathematiker-Vereinigung (DMV), Braunschweig, DE, Mar 7-11, 2016 VL - 16 IS - 1 SP - 99 EP - 100 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Scheidweiler, Robert A1 - Triesch, Eberhard T1 - A note on the duality between matchings and vertex covers in balanced hypergraphs JF - Journal of Combinatorial Optimization N2 - We present a new Min-Max theorem for an optimization problem closely connected to matchings and vertex covers in balanced hypergraphs. The result generalizes Kőnig’s Theorem (Berge and Las Vergnas in Ann N Y Acad Sci 175:32–40, 1970; Fulkerson et al. in Math Progr Study 1:120–132, 1974) and Hall’s Theorem (Conforti et al. in Combinatorica 16:325–329, 1996) for balanced hypergraphs. KW - Hall’s Theorem KW - Koenig’s Theorem KW - Duality KW - Balanced hypergraph KW - Hypergraph KW - Vertex cover KW - Matching Y1 - 2016 U6 - https://doi.org/10.1007/s10878-015-9887-5 SN - 1573-2886 N1 - Lehrstuhl II für Mathematik RWTH Aachen VL - 32 IS - 2 SP - 639 EP - 644 PB - Springer CY - Berlin ER - TY - JOUR A1 - Beckenbach, Isabel A1 - Scheidweiler, Robert T1 - Perfect ƒ-Matchings and ƒ-Factors in Hypergraphs - A Combinatorial Approach JF - Discrete Mathematics N2 - We prove characterizations of the existence of perfect ƒ-matchings in uniform mengerian and perfect hypergraphs. Moreover, we investigate the ƒ-factor problem in balanced hypergraphs. For uniform balanced hypergraphs we prove two existence theorems with purely combinatorial arguments, whereas for non-uniform balanced hypergraphs we show that the ƒ-factor problem is NP-hard. Y1 - 2016 U6 - https://doi.org/10.1016/j.disc.2017.05.005 SN - 2192-7782 N1 - Als Volltext auch bei ZIB (Zuse Institute Berlin) VL - 240 IS - 10 SP - 2499 EP - 2506 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Koster, Arie A1 - Scheidweiler, Robert A1 - Tieves, Martin T1 - A flow based pruning scheme for enumerative equitable coloring algorithms JF - A flow based pruning scheme for enumerative equitable coloring algorithms N2 - An equitable graph coloring is a proper vertex coloring of a graph G where the sizes of the color classes differ by at most one. The equitable chromatic number is the smallest number k such that G admits such equitable k-coloring. We focus on enumerative algorithms for the computation of the equitable coloring number and propose a general scheme to derive pruning rules for them: We show how the extendability of a partial coloring into an equitable coloring can be modeled via network flows. Thus, we obtain pruning rules which can be checked via flow algorithms. Computational experiments show that the search tree of enumerative algorithms can be significantly reduced in size by these rules and, in most instances, such naive approach even yields a faster algorithm. Moreover, the stability, i.e., the number of solved instances within a given time limit, is greatly improved. Since the execution of flow algorithms at each node of a search tree is time consuming, we derive arithmetic pruning rules (generalized Hall-conditions) from the network model. Adding these rules to an enumerative algorithm yields an even larger runtime improvement. Y1 - 2016 U6 - https://doi.org/10.48550/arXiv.1607.08754 N1 - Lehrstuhl II für Mathematik, RWTH Aachen University SP - 1 EP - 30 ER - TY - JOUR A1 - Levers, A. A1 - Staat, Manfred A1 - Laack, Walter van T1 - Analysis of the long-term effect of the MBST® nuclear magnetic resonance therapy on gonarthrosis JF - Orthopedic Practice Y1 - 2016 VL - 47 IS - 11 SP - 521 EP - 528 ER - TY - JOUR A1 - König, Johannes Alexander A1 - Völker, Veronika A1 - Wolf, Martin R. A1 - Schuba, Marko T1 - Gamified Hacking Offence Simulation-based Training (GHOST) JF - Crisis Prevention Y1 - 2016 VL - 2016 IS - 3 SP - 44 EP - 46 PB - Beta CY - Bonn ER - TY - JOUR A1 - Pinkenburg, Olaf A1 - Schiffels, Johannes A1 - Selmer, Thorsten T1 - Das CoLibry-Konzept – ein Werkzeugkasten für die Synthetische Biologie: Bioproduktion JF - BIOspektrum N2 - Regardless of size or destination, synthetic biology starts with com-parably small information units, which need to be combined and properly arranged in order to achieve a certain goal. This may be the de novo synthesis of individual genes from oligonucleotides, a shuffling of protein domains in order to create novel biocatalysts, the assembly of multiple enzyme encoding genes in metabolic pathway design, or strain development at the production stage. The CoLibry concept has been designed in order to close the gap between recombinant production of individual genes and genome editing. Y1 - 2016 U6 - https://doi.org/10.1007/s12268-016-0734-8 VL - 22 IS - 6 SP - 593 EP - 595 PB - Springer CY - Berlin ER - TY - JOUR A1 - Lopes, Pedro A1 - Leandro, Jorge A1 - Carvalho, Rita F. A1 - Bung, Daniel Bernhard T1 - Alternating skimming flow over a stepped spillway JF - Environmental Fluid Mechanics Y1 - 2017 U6 - https://doi.org/10.1007/s10652-016-9484-x SN - 1573-1510 VL - 17 IS - 2 SP - 303 EP - 322 PB - Springer CY - Berlin ER - TY - JOUR A1 - Rieper, Harald A1 - Gebhardt, Andreas A1 - Stucker, Brent T1 - Selective Laser Melting of the Eutectic Silver-Copper Alloy Ag 28 wt % Cu JF - RTejournal - Forum für Rapid Technologie N2 - The aim of this work was to perform a detailed investigation of the use of Selective Laser Melting (SLM) technology to process eutectic silver-copper alloy Ag 28 wt. % Cu (also called AgCu28). The processing occurred with a Realizer SLM 50 desktop machine. The powder analysis (SEM-topography, EDX, particle distribution) was reported as well as the absorption rates for the near-infrared (NIR) spectrum. Microscope imaging showed the surface topography of the manufactured parts. Furthermore, microsections were conducted for the analysis of porosity. The Design of Experiments approach used the response surface method in order to model the statistical relationship between laser power, spot distance and pulse time. KW - SLM KW - Response Surface Method KW - Porositat KW - Eutectic Silver Copper alloy KW - Additive Manufacturing Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?nbn:de:0009-2-44141 SN - 1614-0923 VL - 13 ER - TY - JOUR A1 - Kern, Alexander T1 - Blitz- und Überspannungsschutz von Kernkraftwerken - Nachweisführung der ausreichenden Sicherheit für leittechnische Einrichtungen auch bei Blitzeinschlägen mit extremen Parametern JF - Atw. International Journal for Nuclear Power N2 - Für das Auftreten extremer Wetterereignisse werden für Kernkraftwerke Eintrittshäufigkeiten für nicht mehr beherrschbare Zustände von unter 10⁻⁴/a gefordert. Dies gilt auch für die Einwirkung von Blitzeinschlägen. Die bisherige Nachweisführung zu Blitz- und Überspannungsschutz eines KKW in Deutschland ist deterministisch. In diesem Bericht werden das Vorgehen für einen entsprechenden Nachweis für leittechnische Einrichtungen der Sicherheitstechnik von KKW, der zur geforderten Zielgröße der Eintrittshäufigkeit führt. Die Ergebnisse werden zusammenfassend bewertet. Y1 - 2016 SN - 1431-5254 VL - 61 IS - 8/9 SP - 534 EP - 543 PB - Inforum CY - Berlin ER - TY - JOUR A1 - Hackl, M. A1 - Andermahr, J. A1 - Staat, Manfred A1 - Bremer, I. A1 - Borggrefe, J. A1 - Prescher, A. A1 - Müller, L. P. A1 - Wegmann, K. T1 - Suture button reconstruction of the central band of the interosseous membrane in Essex-Lopresti lesions: a comparative biomechanical investigation JF - The Journal of Hand Surgery (European Volume) Y1 - 2017 U6 - https://doi.org/10.1177/1753193416665943 SN - 2043-6289 (Online) SN - 1753-1934 (Print) VL - 42 IS - 4 SP - 370 EP - 376 PB - Sage CY - London ER - TY - JOUR A1 - Lind, Thorsten Patric T1 - Zurechenbarkeit des als Mitglied des Aufsichtsrats einer Aktiengesellschaft erlangten Wissens des Prokuristen einer Bank : BGH, Urteil vom 26.04.2016 - XI ZR 108/15 (OLG München) JF - LMK : kommentierte BGH-Rechtsprechung ; in Zsarb. mit der Neuen Juristischen Wochenschrift / Lindenmaier-Möhring N2 - Mit der vorliegenden, parallel entsprechend in 10 weiteren Verfahren ergangenen Entscheidung behandelte der BGH zum wiederholten Male das Geschäftsmodell der Accessio Wertpapierhandelshaus AG („A AG“, früher: Wertpapierhandelshaus Driver & Bengsch AG). Die klagenden Anleger, zunächst nur akquiriert durch ein Tagesgeldkonto mit besonders attraktiven Zinsen, schlossen im Weiteren mit dieser einen Vermögensverwaltungsvertrag ab. Zur Abwicklung der Wertpapiergeschäfte eröffneten sie über die A AG zugleich ein Depotkonto bei der beklagten Discount-Brokerin. Für dieses erhielt die A AG eine Transaktionsvollmacht. Die Discount-Brokerin schuldete nach den Vertragsdokumenten über die gesetzlichen Aufklärungs- und Erkundigungspflichten bei Auftragsausführung hinaus keine Anlageberatung („execution-only-business“). Durch nach ihrer Behauptung fehlerhafte Anlageberatung der A AG erlitten die Anleger einen Schaden. In dem Rechtsstreit verlangten sie dessen Ersatz von der Discount-Brokerin, da die A AG zwischenzeitlich insolvent wurde. Y1 - 2016 SN - 1611-1095 SP - 380532 PB - Beck CY - München ER - TY - JOUR A1 - Albanna, W. A1 - Conzen, C. A1 - Weiss, M. A1 - Clusmann, H. A1 - Fuest, M. A1 - Mueller, M. A1 - Brockmann, M.A. A1 - Vilser, W. A1 - Schmidt-Trucksäss, A. A1 - Hoellig, A. A1 - Seiz, M. A1 - Thomé, C. A1 - Kotliar, Konstantin A1 - Schubert, G.A. T1 - Retinal Vessel Analysis (RVA) in the context of subarachnoid hemorrhage: A proof of concept study JF - PLoS ONE N2 - Background Timely detection of impending delayed cerebral ischemia after subarachnoid hemorrhage (SAH) is essential to improve outcome, but poses a diagnostic challenge. Retinal vessels as an embryological part of the intracranial vasculature are easily accessible for analysis and may hold the key to a new and non-invasive monitoring technique. This investigation aims to determine the feasibility of standardized retinal vessel analysis (RVA) in the context of SAH. Methods In a prospective pilot study, we performed RVA in six patients awake and cooperative with SAH in the acute phase (day 2–14) and eight patients at the time of follow-up (mean 4.6±1.7months after SAH), and included 33 age-matched healthy controls. Data was acquired using a manoeuvrable Dynamic Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and neurovascular coupling. Results Image quality was satisfactory in the majority of cases (93.3%). In the acute phase after SAH, retinal arteries were significantly dilated when compared to the control group (124.2±4.3MU vs 110.9±11.4MU, p<0.01), a difference that persisted to a lesser extent in the later stage of the disease (122.7±17.2MU, p<0.05). Testing for neurovascular coupling showed a trend towards impaired primary vasodilation and secondary vasoconstriction (p = 0.08, p = 0.09 resp.) initially and partial recovery at the time of follow-up, indicating a relative improvement in a time-dependent fashion. Conclusion RVA is technically feasible in patients with SAH and can detect fluctuations in vessel diameter and autoregulation even in less severely affected patients. Preliminary data suggests potential for RVA as a new and non-invasive tool for advanced SAH monitoring, but clinical relevance and prognostic value will have to be determined in a larger cohort. Y1 - 2016 U6 - https://doi.org/10.1371/journal.pone.0158781 SN - 1932-6203 VL - 11 IS - 7 PB - PLOS CY - San Francisco ER - TY - JOUR A1 - Bäcker, Matthias A1 - Koch, Claudia A1 - Eiben, Sabine A1 - Geiger, Fania A1 - Eber, Fabian A1 - Gliemann, Hartmut A1 - Poghossian, Arshak A1 - Wege, Christina A1 - Schöning, Michael Josef T1 - Tobacco mosaic virus as enzyme nanocarrier for electrochemical biosensors JF - Sensors and Actuators B: Chemical N2 - The conjunction of (bio-)chemical recognition elements with nanoscale biological building blocks such as virus particles is considered as a very promising strategy for the creation of biohybrids opening novel opportunities for label-free biosensing. This work presents a new approach for the development of biosensors using tobacco mosaic virus (TMV) nanotubes or coat proteins (CPs) as enzyme nanocarriers. Sensor chips combining an array of Pt electrodes loaded with glucose oxidase (GOD)-modified TMV nanotubes or CP aggregates were used for amperometric detection of glucose as a model system for the first time. The presence of TMV nanotubes or CPs on the sensor surface allows binding of a high amount of precisely positioned enzymes without substantial loss of their activity, and may also ensure accessibility of their active centers for analyte molecules. Specific and efficient immobilization of streptavidin-conjugated GOD ([SA]-GOD) complexes on biotinylated TMV nanotubes or CPs was achieved via bioaffinity binding. These layouts were tested in parallel with glucose sensors with adsorptively immobilized [SA]-GOD, as well as [SA]-GOD crosslinked with glutardialdehyde, and came out to exhibit superior sensor performance. The achieved results underline a great potential of an integration of virus/biomolecule hybrids with electronic transducers for future applications in biosensorics and biochips. Y1 - 2017 U6 - https://doi.org/10.1016/j.snb.2016.07.096 SN - 0925-4005 VL - 238 SP - 716 EP - 722 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Lanzl, I. M. T1 - Mit Statistik gemeistert: perfekte Augentropfen und idealer Screeningtest : Möglichkeiten und Grenzen statistischer Methoden beim Glaukom JF - Der Ophthalmologe: Zeitschrift Der Deutschen Ophthalmologischen Gesellschaft N2 - Hintergrund Die Anwendung und das Verständnis von Statistik sind sehr wichtig für die biomedizinische Forschung und für die klinische Praxis. Dies gilt insbesondere auch zur Abschätzung der Möglichkeiten unterschiedlichster Diagnostik- und Therapieoptionen beim Glaukom. Die scheinbare Komplexität der Statistik, die zum Teil dem „gesunden Menschenverstand“ zu widersprechen scheint, zusammen mit der nur vorsichtigen Akzeptanz der Statistik bei vielen Medizinern können zu bewussten und unbewussten Manipulationen bei der Datendarstellung und -interpretation führen. Ziel der Arbeit Ziel ist die verständliche Darstellung einiger typischer Fehler in der medizinisch-statistischen Datenbehandlung. Material und Methoden Anhand hypothetischer Beispiele aus der Glaukomdiagnostik erfolgen die Darstellung der Wirkung eines hypotensiven Medikamentes sowie die Beurteilung der Ergebnisse eines diagnostischen Tests. Es werden die typischsten statistischen Einsatzbereiche und Irrtumsquellen ausführlich und verständlich analysiert Ergebnisse Mechanismen von Datenmanipulation und falscher Dateninterpretation werden aufgeklärt. Typische Irrtumsquellen bei der statistischen Auswertung und Datendarstellung werden dabei erläutert. Schlussfolgerungen Die erläuterten praktischen Beispiele zeigen die Notwendigkeit, die Grundlagen der Statistik zu verstehen und korrekt anwenden zu können. Fehlendes Grundlagenwissen und Halbwissen der medizinischen Statistik können zu folgenschweren Missverständnissen und falschen Entscheidungen in der medizinischen Forschung, aber auch in der klinischen Praxis führen. Y1 - 2016 U6 - https://doi.org/10.1007/s00347-016-0312-y SN - 0941-293X SN - 1433-0423 N1 - Englischer Titel: Mastered with statistics: perfect eye drops and ideal screening test : possibilities and limits of statistical methods for glaucoma IS - 113 SP - 838 EP - 843 PB - Springer CY - Berlin ER - TY - JOUR A1 - Heinze, D. A1 - Mang, Thomas A1 - Popescu, C. A1 - Weichold, O. T1 - Effect of side chain length and degree of polymerization on the decomposition and crystallization behaviour of chlorinated poly(vinyl ester) oligomers JF - Thermochimica Acta N2 - Four members of a homologous series of chlorinated poly(vinyl ester) oligomers CCl₃–(CH₂CH (OCO(CH₂)ₘCH₃))ₙ–Cl with degrees of polymerization of 10 and 20 were prepared by telomerisation using carbon tetrachloride. The number of side chain carbon atoms ranges from 2 (poly(vinyl acetate) to 18 (poly(vinyl stearate)). The effect of the n-alkyl side chain length and of the degree of polymerization on the thermal stability and crystallization behaviour of the synthesized compounds was investigated. All oligomers degrade in two major steps by first losing HCl and side chains with subsequent breakdown of the backbone. The members with short side chains, up to poly(vinyl octanoate), are amorphous and show internal plasticization, whereas those with high number of side chain carbon atoms are semi-crystalline due to side-chain crystallization. A better packing for poly(vinyl stearate) is also noticeable. The glass transition and melting temperatures as well as the onset temperature of decomposition are influenced to a larger extent by the side chain length than by the degree of polymerization. Thermal stability is improved if both the size and number of side chains increase, but only a long side chain causes a significant increase of the resistance to degradation. This results in a stabilization of PVAc so that oligomers from poly(vinyl octanoate) on are stable under atmospheric conditions. Thus, the way to design stable, chlorinated PVEs oligomers is to use a long n-alkyl side chain. Y1 - 2016 U6 - https://doi.org/10.1016/j.tca.2016.05.015 SN - 0040-6031 (electronic) VL - 637 SP - 143 EP - 153 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Haag, S. A1 - Zontar, D. A1 - Schleupen, Josef A1 - Müller, T. A1 - Brecher, C. T1 - Chain of refined perception in self-optimizing assembly of micro-optical systems JF - Journal of sensors and sensor systems N2 - Today, the assembly of laser systems requires a large share of manual operations due to its complexity regarding the optimal alignment of optics. Although the feasibility of automated alignment of laser optics has been shown in research labs, the development effort for the automation of assembly does not meet economic requirements – especially for low-volume laser production. This paper presents a model-based and sensor-integrated assembly execution approach for flexible assembly cells consisting of a macro-positioner covering a large workspace and a compact micromanipulator with camera attached to the positioner. In order to make full use of available models from computer-aided design (CAD) and optical simulation, sensor systems at different levels of accuracy are used for matching perceived information with model data. This approach is named "chain of refined perception", and it allows for automated planning of complex assembly tasks along all major phases of assembly such as collision-free path planning, part feeding, and active and passive alignment. The focus of the paper is put on the in-process image-based metrology and information extraction used for identifying and calibrating local coordinate systems as well as the exploitation of that information for a part feeding process for micro-optics. Results will be presented regarding the processes of automated calibration of the robot camera as well as the local coordinate systems of part feeding area and robot base. Y1 - 2014 U6 - https://doi.org/10.5194/jsss-3-87-2014 SN - 2194-878X VL - 3 IS - 1 SP - 87 EP - 95 PB - Copernicus Publ. CY - Göttingen ER - TY - JOUR A1 - Valero, Daniel A1 - Bung, Daniel Bernhard T1 - Sensitivity of turbulent Schmidt number and turbulence model to simulations of jets in crossflow JF - Environmental Modelling and Software N2 - Environmental discharges have been traditionally designed by means of cost-intensive and time-consuming experimental studies. Some extensively validated models based on an integral approach have been often employed for water quality problems, as recommended by USEPA (i.e.: CORMIX). In this study, FLOW-3D is employed for a full 3D RANS modelling of two turbulent jet-to-crossflow cases, including free surface jet impingement. Results are compared to both physical modelling and CORMIX to better assess model performance. Turbulence measurements have been collected for a better understanding of turbulent diffusion's parameter sensitivity. Although both studied models are generally able to reproduce jet trajectory, jet separation downstream of the impingement has been reproduced only by RANS modelling. Additionally, concentrations are better reproduced by FLOW-3D when the proper turbulent Schmidt number is used. This study provides a recommendation on the selection of the turbulence model and the turbulent Schmidt number for future outfall structures design studies. Y1 - 2016 U6 - https://doi.org/10.1016/j.envsoft.2016.04.030 SN - 1364-8152 (electronic) VL - 82 SP - 218 EP - 228 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jablonowski, Nicolai David A1 - Kollmann, Tobias A1 - Nabel, Moritz A1 - Damm, Tatjana A1 - Klose, Holger A1 - Müller, Michael A1 - Bläsing, Marc A1 - Seebold, Sören A1 - Krafft, Simone A1 - Kuperjans, Isabel A1 - Dahmen, Markus A1 - Schurr, Ulrich T1 - Valorization of Sida (Sida hermaphrodita) biomass for multiple energy purposes JF - GCB [Global Change Biology] Bioenergy N2 - The performance and biomass yield of the perennial energy plant Sida hermaphrodita (hereafter referred to as Sida) as a feedstock for biogas and solid fuel was evaluated throughout one entire growing period at agricultural field conditions. A Sida plant development code was established to allow comparison of the plant growth stages and biomass composition. Four scenarios were evaluated to determine the use of Sida biomass with regard to plant development and harvest time: (i) one harvest for solid fuel only; (ii) one harvest for biogas production only; (iii) one harvest for biogas production, followed by a harvest of the regrown biomass for solid fuel; and (iv) two consecutive harvests for biogas production. To determine Sida's value as a feedstock for combustion, we assessed the caloric value, the ash quality, and melting point with regard to DIN EN ISO norms. The results showed highest total dry biomass yields of max. 25 t ha⁻¹, whereas the highest dry matter of 70% to 80% was obtained at the end of the growing period. Scenario (i) clearly indicated the highest energy recovery, accounting for 439 288 MJ ha⁻¹; the energy recovery of the four scenarios from highest to lowest followed this order: (i) ≫ (iii) ≫ (iv) > (ii). Analysis of the Sida ashes showed a high melting point of >1500 °C, associated with a net calorific value of 16.5–17.2 MJ kg⁻¹. All prerequisites for DIN EN ISO norms were achieved, indicating Sida's advantage as a solid energy carrier without any post-treatment after harvesting. Cell wall analysis of the stems showed a constant lignin content after sampling week 16 (July), whereas cellulose had already reached a plateau in sampling week 4 (April). The results highlight Sida as a promising woody, perennial plant, providing biomass for flexible and multipurpose energy applications. Y1 - 2016 U6 - https://doi.org/10.1111/gcbb.12346 SN - 1757-1707 (online) SN - 1757-1693 (print) N1 - Special Issue: Perennial biomass crops for a resource constrained world VL - 9 IS - 1 SP - 202 EP - 214 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Ghosch, S. A1 - Baier, M. A1 - Schütz, J. A1 - Schneider, Felix A1 - Scherer, Ulrich W. T1 - Analysis of electronic autoradiographs by mathematical post-processing JF - Radiation Effects and Defects in Solids: Incorporating plasma science and plasma technology N2 - Autoradiography is a well-established method of nuclear imaging. When different radionuclides are present simultaneously, additional processing is needed to distinguish distributions of radionuclides. In this work, a method is presented where aluminium absorbers of different thickness are used to produce images with different cut-off energies. By subtracting images pixel-by-pixel one can generate images representing certain ranges of β-particle energies. The method is applied to the measurement of irradiated reactor graphite samples containing several radionuclides to determine the spatial distribution of these radionuclides within pre-defined energy windows. The process was repeated under fixed parameters after thermal treatment of the samples. The greyscale images of the distribution after treatment were subtracted from the corresponding pre-treatment images. Significant changes in the intensity and distribution of radionuclides could be observed in some samples. Due to the thermal treatment parameters the most significant differences were observed in the ³H and ¹⁴C inventory and distribution. Y1 - 2016 U6 - https://doi.org/10.1080/10420150.2016.1155587 SN - 1029-4953 VL - 171 IS - 1-2 SP - 161 EP - 172 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Valero, Daniel A1 - Bung, Daniel Bernhard T1 - Development of the interfacial air layer in the non-aerated region of high-velocity spillway flows: Instabilities growth, entrapped air and influence on the self-aeration onset JF - International Journal of Multiphase Flow N2 - Self-aeration is traditionally explained by the water turbulent boundary layer outer edge intersection with the free surface. This paper presents a discussion on the commonly accepted hypothesis behind the computation of the critical point of self-aeration in spillway flows and a new formulation is proposed based on the existence of a developing air flow over the free surface. Upstream of the inception point of self-aeration, some surface roughening has been often reported in previous studies which consequently implies some entrapped air transport and air–water flows coupling. Such air flow is proven in this study by presenting measured air velocities and computing the air boundary layer thickness for a 1V:2H smooth chute flow. Additionally, the growth rate of free surface waves has been analysed by means of Ultrasonic Sensors measurements, obtaining also the entrapped air concentration. High-speed camera imaging has been used for qualitative study of the flow perturbations. Y1 - 2016 U6 - https://doi.org/10.1016/j.ijmultiphaseflow.2016.04.012 SN - 0301-9322 VL - 84 SP - 66 EP - 74 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Molinnus, Denise A1 - Sorich, Maren A1 - Bartz, Alexander A1 - Siegert, Petra A1 - Willenberg, Holger S. A1 - Lisdat, Fred A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Towards an adrenaline biosensor based on substrate recycling amplification in combination with an enzyme logic gate JF - Sensors and Actuators B: Chemical N2 - An amperometric biosensor using a substrate recycling principle was realized for the detection of low adrenaline concentrations (1 nM) by measurements in phosphate buffer and Ringer’s solution at pH 6.5 and pH 7.4, respectively. In proof-of-concept experiments, a Boolean logic-gate principle has been applied to develop a digital adrenaline biosensor based on an enzyme AND logic gate. The obtained results demonstrate that the developed digital biosensor is capable for a rapid qualitative determination of the presence/absence of adrenaline in a YES/NO statement. Such digital biosensor could be used in clinical diagnostics for the control of a correct insertion of a catheter in the adrenal veins during adrenal venous-sampling procedure. Y1 - 2016 U6 - https://doi.org/10.1016/j.snb.2016.06.064 SN - 0925-4005 VL - 237 SP - 190 EP - 195 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Knobe, M. A1 - Giesen, M. A1 - Plate, S. A1 - Gradl-Dietsch, G. A1 - Buecking, B. A1 - Eschbach, D. A1 - Laack, Walter van A1 - Pape, H.-C. T1 - The Aachen mobility and balance index to measure physiological falls risk: a comparison with the Tinetti POMA scale JF - European Journal Of Trauma And Emergency Surgery N2 - Purpose The most commonly used mobility assessments for screening risk of falls among older adults are rating scales such as the Tinetti performance oriented mobility assessment (POMA). However, its correlation with falls is not always predictable and disadvantages of the scale include difficulty to assess many of the items on a 3-point scale and poor specificity. The purpose of this study was to describe the ability of the new Aachen Mobility and Balance Index (AMBI) to discriminate between subjects with a fall history and subjects without such events in comparison to the Tinetti POMA Scale. Methods For this prospective cohort study, 24 participants in the study group and 10 in the control group were selected from a population of patients in our hospital who had met the stringent inclusion criteria. Both groups completed the Tinetti POMA Scale (gait and balance component) and the AMBI (tandem stance, tandem walk, ten-meter-walk-test, sit-to-stand with five repetitions, 360° turns, timed-up-and-go-test and measurement of the dominant hand grip strength). A history of falls and hospitalization in the past year were evaluated retrospectively. The relationships among the mobility tests were examined with Bland–Altmananalysis. Receiver-operated characteristics curves, sensitivity and specificity were calculated. Results The study showed a strong negative correlation between the AMBI (17 points max., highest fall risk) and Tinetti POMA Scale (28 points max., lowest fall risk; r = −0.78, p < 0.001) with an excellent discrimination between community-dwelling older people and a younger control group. However, there were no differences in any of the mobility and balance measurements between participants with and without a fall history with equal characteristics in test comparison (AMBI vs. Tinetti POMA Scale: AUC 0.570 vs. 0.598; p = 0.762). The Tinetti POMA Scale (cut-off <20 points) showed a sensitivity of 0.45 and a specificity of 0.69, the AMBI a sensitivity of 0.64 and a specificity of 0.46 (cut-off >5 points). Conclusion The AMBI comprises mobility and balance tasks with increasing difficulty as well as a measurement of the dominant hand-grip strength. Its ability to identify fallers was comparable to the Tinetti POMA Scale. However, both measurement sets showed shortcomings in discrimination between fallers and non-fallers based on a self-reported retrospective falls-status. KW - Tinetti test KW - Mobility KW - Mobility tests KW - Ground-level falls KW - Elderly KW - Fall prevention KW - Co-managed care KW - Balance Y1 - 2016 U6 - https://doi.org/10.1007/s00068-016-0693-2 SN - 1863-9941 VL - 42 IS - 5 SP - 537 EP - 545 PB - Springer CY - Berlin ER - TY - JOUR A1 - Doll, Theodor A1 - Wagner, Torsten A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Engineering of functional interfaces / Theodor Doll ; Torsten Wagner ; Patrick Wagner ; Michael J. Schöning (eds.) JF - Physica status solidi (a) Y1 - 2016 U6 - https://doi.org/10.1002/pssa.201670641 SN - 1862-6319 VL - 213 IS - 6 SP - 1393 EP - 1394 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Wagner, Torsten A1 - Vornholt, Wolfgang A1 - Werner, Frederik A1 - Yoshinobu, Tatsuo A1 - Miyamoto, Ko-Ichiro A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Light-addressable potentiometric sensor (LAPS) combined with magnetic beads for pharmaceutical screening JF - Physics in medicine N2 - The light-addressable potentiometric sensor (LAPS) has the unique feature to address different regions of a sensor surface without the need of complex structures. Measurements at different locations on the sensor surface can be performed in a common analyte solution, which distinctly simplifies the fluidic set-up. However, the measurement in a single analyte chamber prevents the application of different drugs or different concentrations of a drug to each measurement spot at the same time as in the case of multi-reservoir-based set-ups. In this work, the authors designed a LAPS-based set-up for cell culture screening that utilises magnetic beads loaded with the endotoxin (lipopolysaccharides, LPS), to generate a spatially distributed gradient of analyte concentration. Different external magnetic fields can be adjusted to move the magnetic beads loaded with a specific drug within the measurement cell. By recording the metabolic activities of a cell layer cultured on top of the LAPS surface, this work shows the possibility to apply different concentrations of a sample along the LAPS measurement spots within a common analyte solution. Y1 - 2016 U6 - https://doi.org/10.1016/j.phmed.2016.03.001 SN - 2352-4510 VL - 2016 IS - 1 SP - 2 EP - 7 ER - TY - JOUR A1 - Miyamoto, Ko-Ichiro A1 - Sato, Takuya A1 - Abe, Minami A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Light-addressable potentiometric sensor as a sensing element in plug-based microfluidic devices JF - Micromachines N2 - A plug-based microfluidic system based on the principle of the light-addressable potentiometric sensor (LAPS) is proposed. The LAPS is a semiconductor-based chemical sensor, which has a free addressability of the measurement point on the sensing surface. By combining a microfluidic device and LAPS, ion sensing can be performed anywhere inside the microfluidic channel. In this study, the sample solution to be measured was introduced into the channel in a form of a plug with a volume in the range of microliters. Taking advantage of the light-addressability, the position of the plug could be monitored and pneumatically controlled. With the developed system, the pH value of a plug with a volume down to 400 nL could be measured. As an example of plug-based operation, two plugs were merged in the channel, and the pH change was detected by differential measurement. KW - light-addressable potentiometric sensor KW - plug-based microfluidic device KW - chemical sensor Y1 - 2016 U6 - https://doi.org/10.3390/mi7070111 SN - 2072-666X N1 - This article belongs to the Special Issue "Micro/Nano Devices for Chemical Analysis" VL - 7 IS - 7 SP - 111 PB - MDPI CY - Basel ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Evers, Jörg T1 - Phase-controlled pulse propagation in media with cross coupling of electric and magnetic probe field component JF - Physical Review A - Atomic, molecular, and optical physics Y1 - 2009 U6 - https://doi.org/10.1103/PHYSREVA.80.063816 SN - 1050-2947 VL - 80 IS - 6 SP - 063816 ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Evers, Jörg T1 - Four-wave mixing enhanced white-light cavity JF - Physical Review A - Atomic, molecular, and optical physics Y1 - 2008 SN - 0556-2791 VL - 78 IS - 5 SP - 051802(R) ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Evers, Jörg T1 - Nonlinear effects in pulse propagation through Doppler-broadened closed-loop atomic media JF - Physical Review A - Atomic, molecular, and optical physics Y1 - 2008 U6 - https://doi.org/10.1103/PhysRevA.77.043805 SN - 1050-2947 VL - 77 IS - 4 SP - 043805 ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Evers, Jörg A1 - Dey, Tarak N. T1 - Phase modulation induced by cooperative effects in electromagnetically induced transparency JF - Physical Review A - Atomic, molecular, and optical physics N2 - We analyze the influence of dipole-dipole interactions in an electromagnetically induced transparency set up for a density at the onset of cooperative effects. To this end, we include mean-field models for the influence of local-field corrections and radiation trapping into our calculation. We show both analytically and numerically that the polarization contribution to the local field strongly modulates the phase of a weak pulse. We give an intuitive explanation for this local-field-induced phase modulation and demonstrate that it distinctively differs from the nonlinear self-phase-modulation that a strong pulse experiences in a Kerr medium. Y1 - 2010 U6 - https://doi.org/10.1103/PhysRevA.82.013815 SN - 1050-2947 VL - 82 IS - 1 PB - AIP Publishing CY - Melville, NY ER -