TY - JOUR A1 - Hoskens, R.C.P. A1 - Roer, T.G. van de A1 - Tolstikhin, V.I. A1 - Förster, Arnold T1 - Hot electron injection laser: vertically integrated transistor-laser structure for high-speed, low-chirp direct modulation JF - LEOS 2000 : 2000 IEEE annual meeting conference proceedings; 13th annual meeting; IEEE Lasers and Electro-Optics Society 2000 annual meeting; 13-16 November 2000, The Westin Rio Mar Beach, Rio Grande, Puerto Rico. Vol. 2 Y1 - 2000 SN - 0-7803-5947-X N1 - 2000 IEEE LEOS annual meeting SP - 444 EP - 445 PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Vitusevich, S. A. A1 - Förster, Arnold A1 - Indlekofer, K.-M. A1 - Lüth, H. A1 - Belyaev, A. E. A1 - Glavin, B. A. A1 - Konakova, R. V. T1 - Tunneling Through X-Valley-Related Impurity States in GaAs/AlAs Resonant-Tunneling Diodes JF - Physical Review . B. 61 (2000), H. 16 Y1 - 2000 SN - 1550-235X SP - 10898 EP - 10904 ER - TY - JOUR A1 - Tillmann, K. A1 - Förster, Arnold T1 - Critical dimensions for the formation of interfacial misfit dislocations of In0.6Ga0.4As islands on GaAs(001) JF - Thin Solid Films. 368 (2000), H. 1 Y1 - 2000 SN - 0040-6090 SP - 93 EP - 104 ER - TY - JOUR A1 - Vitusevich, S. A. A1 - Förster, Arnold A1 - Reetz, W. A1 - Lüth, H. A1 - Belyaev, A. E. A1 - Danylyuk, S. V. T1 - Spectral Responsivity of single-quantum-well photodetectors JF - Applied Physics Letters. 77 (2000), H. 1 Y1 - 2000 SN - 1077-3118 SP - 16 EP - 18 ER - TY - CHAP A1 - Zischank, Wolfgang J. A1 - Kern, Alexander A1 - Frentzel, Ralf A1 - Heidler, Fridolin A1 - Seevers, M. T1 - Assessment of the lightning transient coupling to control cables interconnecting structures in large industrial facilities and power plants N2 - Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I&C-cables. KW - Blitzschutz KW - Elektromagnetische Kopplung KW - Überspannung KW - Kraftwerke KW - Industrieanlagen KW - Lightning KW - current distribution KW - electromagnetic coupling KW - overvoltages Y1 - 2000 ER -