TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, M. A1 - Arora, D. A1 - Coronado, O. A1 - Pasquali, M. T1 - CFD Analysis of MicroMed Debakey Pump and Hemolysis Prediction / Behbahani, M. ; Behr, M. ; Arora, D. ; Coronado, O. ; Pasquali, M. JF - Artificial Organs. 30 (2006), H. 11 Y1 - 2006 SN - 1525-1594 N1 - Abstracts 14th Congress of the International Society for Rotary Blood Pumps, Leuven, Belgium, August 31–September 2, 2006 ; S7-4 SP - A45 EP - A46 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, M. A1 - Bischof, F. A1 - Wolf, G. E. T1 - Kranken Herzen helfen - Ingenieure und Informatiker entwickeln gemeinsam eine Miniaturblutpumpe / Behbahani, M. ; Behr, M. ; Bischof, F. ; Wolf, G. E. JF - RWTH-Themen (2007) Y1 - 2007 SN - 0179-079X SP - 44 EP - 46 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, M. A1 - Hormes, M. A1 - Steinseifer, U. A1 - Arora, D. A1 - Coronado, O. A1 - Pasquali, M. T1 - A Review of Computational Fluid Dynamics Analysis of Blood Pumps JF - European Journal of Applied Mathematics. 20 (2009), H. 4 Y1 - 2009 SP - 363 EP - 397 PB - Cambridge Univ. Press CY - Cambridge ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, Marek A1 - Nicolai, Mike A1 - Probst, Markus T1 - Towards Shape Optimization for Ventricular Assist Devices Using Parallel Stabilized FEM JF - NIC Symposium 2008 : symposium, 20 - 21 February 2008, Forschungszentrum Jülich ; proceedings / organized by John von Neumann Institute for Computing. Ed. by Gernot Münster; Dietrich Wolf; Manfred Kremer (ed.) Y1 - 2008 SN - 978-3-9810843-5-1 N1 - NIC series ; 39 SP - 325 EP - 332 PB - Forschungszentrum CY - Jülich ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Finocchiaro, Thomas A1 - Heinke, Stefanie A1 - Leßmann, Marc T1 - Methods of design, simulation, and control for the development of new VAD/TAH concepts = Methoden zur Konstruktion, Simulation und Regelung für die Entwicklung von neuen VAD/TAH-Konzepten / Finocchiaro, Thomas ; Heinke, Stefanie ; Behbahani, Mehdi ; Leßma JF - Biomedizinische Technik / Biomedical Engineering. 54 (2009), H. 5 Y1 - 2009 SN - 0013-5585 N1 - Printausgabe in der Bereichsbibliothek Jülich vorhanden : 63 Z 471 SP - 269 EP - 281 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Mai, A. A1 - Bergmann, B. A1 - Waluga, C. A1 - Behr, M. A1 - Tran, L. A1 - Vonderstein, K. A1 - Mottaghy, K. T1 - Modeling and Numerical Simulation of Blood Damage Y1 - 2010 N1 - Posterpresentation ; Umbrella Symposium "Modelling and Simulation in Medicine, Engineering and Sciences", Forschungszentrum Jülich, January 18-20, 2010 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Mai, A. A1 - Waluga, C. A1 - Bergmann, B. A1 - Tran, L. A1 - Vonderstein, K. A1 - Behr, M. A1 - Mottaghy, K. T1 - Numerical Modeling of Flow-Related Thrombus Formation under Physiological and Non-Physiological Flow Conditions JF - Acta Physiologica Y1 - 2010 SN - 1748-1716 N1 - Joint Congress of the Scandinavian and German Physiological Societies, Copenhagen, Denmark, March 27-30, 2010 VL - 198 IS - Supplement 677 SP - 185 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Nam, J. A1 - Waluga, C. A1 - Behr, M. A1 - Pasquali, M. A1 - Mottaghy, K. T1 - Modeling and Numerical Analysis of Platelet Activation, Adhesion and Aggregation in Artificial Organs Y1 - 2010 U6 - http://dx.doi.org/10.1097/01.mat.0000369377.65122.a3 N1 - Posterpresentation American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Nicolai, M. T1 - Interaktive Exploration von Blutströmungsprozessen in Herzpumpen JF - VRCA-Jahresbericht 2005/2006 Y1 - 2006 N1 - Virtual Reality Center SP - 88 EP - 90 PB - Virtual Reality Center CY - Aachen ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Nicolai, M. A1 - Probst, M. A1 - Behr, M. T1 - Simulation of Blood Flow in a Ventricular Assist Device JF - inSIDE. 5 (2007), H. 1 Y1 - 2007 SP - 28 EP - 31 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Probst, M. A1 - Mai, A. A1 - Behr, M. A1 - Tran, L. A1 - Vonderstein, K. A1 - Mottaghy, K. T1 - Numerical Prediction of Blood Damage in Biomedical Devices Y1 - 2010 N1 - Posterpresentation ; Biomedica Congress, Aachen, March 17-18, 2010 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Probst, M. A1 - Mai, A. A1 - Tran, L. A1 - Vonderstein, K. A1 - Keschenau, P. A1 - Linde, T. A1 - Steinseifer, U. A1 - Behr, M. A1 - Mottaghy, K. T1 - The influence of high shear on thrombosis and hemolysis in artificial organs JF - Artificial Organs Y1 - 2010 SN - 0391-3988 N1 - Special Issue: SI ; Meeting abstract VL - 33 IS - 7 SP - 426 EP - 426 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Spillner, Jan A1 - Kopp, Rüdiger A1 - Finocchiaro, Thomas T1 - Assistierte Zirkulation : ein Überblick aus klinischer Sicht = Assisted circulation: an overview from a clinical perspective / Spillner, Jan ; Kopp, Rüdiger ; Finocchiaro, Thomas ; Behbahani, Mehdi ; Rossaint, Rolf ; Steinseifer, Ulrich ; Behr, Marek ; Au JF - Biomedizinische Technik / Biomedical Engineering. 54 (2009), H. 5 Y1 - 2009 SN - 0013-5585 N1 - Printausgabe in der Bereichsbibliothek Jülich vorhanden : 63 Z 471 SP - 255 EP - 267 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Tran, L. A1 - Jockenhövel, S. A1 - Behr, M. A1 - Mottaghy, K. T1 - Numerical prediction of thrombocyte reactions for application to a vascular flow model JF - British Journal of Surgery Y1 - 2011 SN - 1365-2168 N1 - 46th Congress of the European Society for Surgical Research, Aachen, Germany, 25-28 May 2011 ; ESSR Abstracts 2011 ; Oral Sessions OP10-5 VL - 98 IS - S5 SP - S17 PB - Oxford University Press CY - Oxford ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Tran, L. A1 - Waluga, C. A1 - Behr, M. A1 - Oedekoven, B. A1 - Mottaghy, K. T1 - Model-based Numerical Analysis of Platelet Adhesion, Thrombus Growth and Aggregation for Assist Devices JF - The International Journal of Artificial Organs. 32 (2009), H. 7 Y1 - 2009 SN - 0391-3988 N1 - Abstracts - Oral Presentations: XXXVI Annual ESAO Congress, 2-5 September 2009, Compiègne - France; European Society of Artificial Organs (ESAO), Compiegne, France, September 2-5, 2009 SP - 398 EP - 398 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Waluga, C. A1 - Arlt, S. A1 - Behr, M. A1 - Mottaghy, K. T1 - Computational Analysis of Platelet Aggregation in a Taylor-Couette System JF - The International Journal of Artificial Organs. 31 (2008), H. 7 Y1 - 2008 SN - 0391-3988 N1 - Posterpresentation ; European Society of Artificial Organs (ESAO), Geneva, Switzerland SP - 643 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Waluga, C. A1 - Stock, S. A1 - Mai, A. A1 - Bergmann, B. A1 - Behr, M. A1 - Tran, L. A1 - Vonderstein, K. A1 - Scheidt, H. A1 - Oedekoven, B. A1 - Mottaghy, K. T1 - Modelling and Numerical Analysis of Platelet Reactions and Surface Thrombus Growth Y1 - 2009 N1 - Posterpresentation ; European Society of Biomaterials (ESB), Lausanne, Switzerland, September 7-10, 2009 ER - TY - JOUR A1 - Brockhaus, Moritz K. A1 - Behbahani, Mehdi A1 - Muris, Farina A1 - Jansen, Sebastian V. A1 - Schmitz- Rode, Thomas A1 - Steinseifer, Ulrich A1 - Clauser, Johanna C. T1 - In vitro thrombogenicity testing of pulsatile mechanical circulatory support systems: Design and proof-of-concept JF - Artificial Organs N2 - Thrombogenic complications are a main issue in mechanical circulatory support (MCS). There is no validated in vitro method available to quantitatively assess the thrombogenic performance of pulsatile MCS devices under realistic hemodynamic conditions. The aim of this study is to propose a method to evaluate the thrombogenic potential of new designs without the use of complex in-vivo trials. This study presents a novel in vitro method for reproducible thrombogenicity testing of pulsatile MCS systems using low molecular weight heparinized porcine blood. Blood parameters are continuously measured with full blood thromboelastometry (ROTEM; EXTEM, FIBTEM and a custom-made analysis HEPNATEM). Thrombus formation is optically observed after four hours of testing. The results of three experiments are presented each with two parallel loops. The area of thrombus formation inside the MCS device was reproducible. The implantation of a filter inside the loop catches embolizing thrombi without a measurable increase of platelet activation, allowing conclusions of the place of origin of thrombi inside the device. EXTEM and FIBTEM parameters such as clotting velocity (α) and maximum clot firmness (MCF) show a total decrease by around 6% with a characteristic kink after 180 minutes. HEPNATEM α and MCF rise within the first 180 minutes indicate a continuously increasing activation level of coagulation. After 180 minutes, the consumption of clotting factors prevails, resulting in a decrease of α and MCF. With the designed mock loop and the presented protocol we are able to identify thrombogenic hot spots inside a pulsatile pump and characterize their thrombogenic potential. Y1 - 2021 U6 - http://dx.doi.org/10.1111/aor.14046 SN - 1525-1594 VL - 45 IS - 12 SP - 1513 EP - 1521 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Chloé, Radermacher A1 - Malyaran, Hanna A1 - Craveiro, Rogerio Bastos A1 - Peglow, Sarah A1 - Behbahani, Mehdi A1 - Pufe, Thomas A1 - Wolf, Michael A1 - Neuss, Sabine T1 - Mechanical loading on cementoblasts: a mini review JF - Osteologie N2 - Orthodontic treatments are concomitant with mechanical forces and thereby cause teeth movements. The applied forces are transmitted to the tooth root and the periodontal ligaments which is compressed on one side and tensed up on the other side. Indeed, strong forces can lead to tooth root resorption and the crown-to-tooth ratio is reduced with the potential for significant clinical impact. The cementum, which covers the tooth root, is a thin mineralized tissue of the periodontium that connects the periodontal ligament with the tooth and is build up by cementoblasts. The impact of tension and compression on these cells is investigated in several in vivo and in vitro studies demonstrating differences in protein expression and signaling pathways. In summary, osteogenic marker changes indicate that cyclic tensile forces support whereas static tension inhibits cementogenesis. Furthermore, cementogenesis experiences the same protein expression changes in static conditions as static tension, but cyclic compression leads to the exact opposite of cyclic tension. Consistent with marker expression changes, the singaling pathways of Wnt/ß-catenin and RANKL/OPG show that tissue compression leads to cementum degradation and tension forces to cementogenesis. However, the cementum, and in particular its cementoblasts, remain a research area which should be explored in more detail to understand the underlying mechanism of bone resorption and remodeling after orthodontic treatments. KW - Cementoblast KW - Compression KW - Tension KW - Mechanotransduction KW - Forces Y1 - 2022 U6 - http://dx.doi.org/10.1055/a-1826-0777 SN - 1019-1291 VL - 31 IS - 2 SP - 111 EP - 118 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Doorschodt, B. M. A1 - Schreinemachers, M. C. J. M. A1 - Behbahani, Mehdi A1 - Florquin, S. A1 - Weis, J. A1 - Staat, Manfred A1 - Tolba, R. H. T1 - Hypothermic machine perfusion of kidney grafts: which pressure is preferred JF - Annals of Biomedical Engineering. 39 (2011), H. 3 Y1 - 2011 SN - 1573-9686 SP - 1051 EP - 1059 PB - Springer CY - Berlin ER -