TY - JOUR A1 - Schwager, Christian A1 - Flesch, Robert A1 - Schwarzbözl, Peter A1 - Herrmann, Ulf A1 - Teixeira Boura, Cristiano José T1 - Advanced two phase flow model for transient molten salt receiver system simulation JF - Solar Energy N2 - In order to realistically predict and optimize the actual performance of a concentrating solar power (CSP) plant sophisticated simulation models and methods are required. This paper presents a detailed dynamic simulation model for a Molten Salt Solar Tower (MST) system, which is capable of simulating transient operation including detailed startup and shutdown procedures including drainage and refill. For appropriate representation of the transient behavior of the receiver as well as replication of local bulk and surface temperatures a discretized receiver model based on a novel homogeneous two-phase (2P) flow modelling approach is implemented in Modelica Dymola®. This allows for reasonable representation of the very different hydraulic and thermal properties of molten salt versus air as well as the transition between both. This dynamic 2P receiver model is embedded in a comprehensive one-dimensional model of a commercial scale MST system and coupled with a transient receiver flux density distribution from raytracing based heliostat field simulation. This enables for detailed process prediction with reasonable computational effort, while providing data such as local salt film and wall temperatures, realistic control behavior as well as net performance of the overall system. Besides a model description, this paper presents some results of a validation as well as the simulation of a complete startup procedure. Finally, a study on numerical simulation performance and grid dependencies is presented and discussed. KW - Molten salt solar tower KW - Molten salt receiver system KW - Dynamic simulation KW - Two-phase modelling KW - Transient flux distribution Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.solener.2021.12.065 SN - 0038-092X (print) SN - 1471-1257 (online) VL - 232 SP - 362 EP - 375 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Timmer, H. T1 - Energetische und betriebswirtschaftliche Bewertung von Kühlsystemen für Kühllager JF - HLH. Heizung, Lüftung/Klima, Haustechnik KW - Heizung KW - Lüftung KW - Klimatechnik KW - Lüftungstechnik KW - Haustechnik Y1 - 1998 SN - 1436-5103 VL - 49 IS - 9 SP - 74 EP - 77 PB - Springer CY - Düsseldorf ER - TY - JOUR A1 - Thulfaut, Christian A1 - Groß, Rolf Fritz T1 - Experimentelle Untersuchung der Luftstromvermischung in Hybridzellenkühltürmen JF - HLH. Heizung, Lüftung/Klima, Haustechnik N2 - Zwangsbelüftete Nasskühltürme haben im Gegensatz zur Trockenkühlung bei naßkaltem Wetter Nebelschwaden zur Folge. Dagegen ist bei Naßkühlung die spezifische Kühlleistung durch abgeführte Kondensationswärme höher als bei der Trockenkühlung. Hybridzellenkühltürme kombinieren beide Methoden, so daß ein Mischstrom beider Abluftströme die Wasserdampf-Sättigungsgrenze nicht überschreitet. Durch das Mischungsverhältnis kann man den gewünschten Sättigungsgrad einstellen. Je dichter dieser an der Sättigungsgrenze liegt, desto höher ist die Kühlleistung. Der von unten zugeführte Luftstrom der Naßkühlung und der seitlich zugeführte trockene Abluftstrom müssen sehr gut durchmischt werden, um über den gesamten Austrittsquerschnitt des Kühlturms die Sättigungsgrenze nicht zu überschreiten. In einem maßstabsgerechten Modell wurde der Mischungsgrad mit und ohne Einbauten untersucht. Über ein Raster von 10 mal 10 Punkten wurde die örtliche Temperaturverteilung ermittelt. Wärmebilanzen ergeben dann die Mischungsgüte in einer Ebene oberhalb der Zellenkrone. Während ohne Mischeinbauten der Trockenluftanteil in der Mitte des Querschnitts bei unter 15 % liegt erhöhen Einbauten den Trockenluftanteil auf 30 % bis über 40 %. Dabei wurde die Trockenluft auf jeder Kühlturmseite durch 4 konisch zulaufende, unten offene und oben geschlitzte Einbauten kanalisiert. Die Nassluft wurde durch eine im Querschnitt dreieckige Rinne in Richtung der Trockenluftauslässe umgelenkt. Im Raster leicht zu lokalisierende Abweichungen vom gewünschten Mittelwert zeigen Potential für die weitere Verbesserung der Einbauten. KW - Trockenkühlturm KW - Nasskühlturm KW - kombiniertes Verfahren KW - Mischen KW - Abluft Y1 - 2000 SN - 1436-5103 VL - 51 IS - 8 SP - 48 EP - 49 PB - Springer CY - Düsseldorf ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Berger, J. A1 - Groß, H. T1 - Gebäudeautomation - Betriebsdatenerfassung und Gebäudeleittechnik im Klartext T1 - Operating data- and facility management in clear JF - HLH. Heizung, Lüftung/Klima, Haustechnik KW - Heizung KW - Lüftung KW - Klimatechnik KW - Lüftungstechnik KW - Haustechnik Y1 - 2003 SN - 1436-5103 VL - 54 IS - 2 SP - 81 PB - Springer CY - Düsseldorf ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Berger, J. T1 - Quo Vadis - Ausblick in die Gebäudeleittechnik der Zukunft T1 - Whitherfacility management? An outlook to the future JF - HLH. Heizung, Lüftung/Klima, Haustechnik N2 - Auf dem Weg zum vernetzten Haus stoßen Hersteller und Planer, insbesondere im privaten Wohnungsbau, zur Zeit noch auf erhebliche Widerstände bei der Durchdringung des Marktes. N2 - Producers and planners of facility management systems are still faced with building owners' reluctance, especially when it comes to private homes. Y1 - 2005 SN - 1436-5103 VL - 56 IS - 1 SP - 39 EP - 41 PB - Springer CY - Düsseldorf ER - TY - JOUR A1 - Peere, Wouter A1 - Blanke, Tobias ED - Vernon, Chris T1 - GHEtool: An open-source tool for borefield sizing in Python JF - Journal of Open Source Software N2 - GHEtool is a Python package that contains all the functionalities needed to deal with borefield design. It is developed for both researchers and practitioners. The core of this package is the automated sizing of borefield under different conditions. The sizing of a borefield is typically slow due to the high complexity of the mathematical background. Because this tool has a lot of precalculated data, GHEtool can size a borefield in the order of tenths of milliseconds. This sizing typically takes the order of minutes. Therefore, this tool is suited for being implemented in typical workflows where iterations are required. GHEtool also comes with a graphical user interface (GUI). This GUI is prebuilt as an exe-file because this provides access to all the functionalities without coding. A setup to install the GUI at the user-defined place is also implemented and available at: https://www.mech.kuleuven.be/en/tme/research/thermal_systems/tools/ghetool. KW - geothermal KW - energy KW - borefields KW - sizing Y1 - 2022 U6 - http://dx.doi.org/10.21105/joss.04406 SN - 2475-9066 VL - 7 IS - 76 SP - 1 EP - 4, 4406 ER - TY - JOUR A1 - Gorzalka, Philip A1 - Schmiedt, Jacob Estevam A1 - Schorn, Christian T1 - Automated Generation of an Energy Simulation Model for an Existing Building from UAV Imagery JF - Buildings N2 - An approach to automatically generate a dynamic energy simulation model in Modelica for a single existing building is presented. It aims at collecting data about the status quo in the preparation of energy retrofits with low effort and costs. The proposed method starts from a polygon model of the outer building envelope obtained from photogrammetrically generated point clouds. The open-source tools TEASER and AixLib are used for data enrichment and model generation. A case study was conducted on a single-family house. The resulting model can accurately reproduce the internal air temperatures during synthetical heating up and cooling down. Modelled and measured whole building heat transfer coefficients (HTC) agree within a 12% range. A sensitivity analysis emphasises the importance of accurate window characterisations and justifies the use of a very simplified interior geometry. Uncertainties arising from the use of archetype U-values are estimated by comparing different typologies, with best- and worst-case estimates showing differences in pre-retrofit heat demand of about ±20% to the average; however, as the assumptions made are permitted by some national standards, the method is already close to practical applicability and opens up a path to quickly estimate possible financial and energy savings after refurbishment. KW - Modelica KW - heat transfer coefficient KW - heat demand KW - building energy modelling KW - building energy simulation Y1 - 2021 U6 - http://dx.doi.org/10.3390/buildings11090380 SN - 2075-5309 N1 - This article belongs to the Special Issue "Application of Computer Technology in Buildings" VL - 11 IS - 9 PB - MDPI CY - Basel ER - TY - JOUR A1 - Hagenkamp, Markus A1 - Blanke, Tobias A1 - Döring, Bernd T1 - Thermoelectric building temperature control: a potential assessment JF - International Journal of Energy and Environmental Engineering N2 - This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants. Y1 - 2021 U6 - http://dx.doi.org/10.1007/s40095-021-00424-x N1 - Corresponding author: Markus Hagenkamp VL - 13 SP - 241 EP - 254 PB - Springer CY - Berlin ER - TY - JOUR A1 - Blanke, Tobias A1 - Reger, Vitali A1 - Döring, Bernd A1 - Göttsche, Joachim A1 - Kuhnhenne, Markus T1 - Koaxiale Stahlenergiepfähle JF - Stahlbau N2 - Ein entscheidender Teil der Energiewende ist die Wärmewende im Gebäudesektor. Ein Schlüsselelement sind hier Wärmepumpen. Diese benötigen eine Wärmequelle, der sie Energie entziehen können, um sie auf ein höheres Temperaturniveau zu transformieren. Diese Wärmequelle kann bspw. das Erdreich sein, dessen Wärme durch Erdsonden erschlossen werden kann. In diesem Beitrag werden in Stahlpfähle integrierte Koaxialsonden mit dem Stand der Technik von Erdsonden gleichen Durchmessers bezüglich ihrer thermischen Leistungsmerkmale verglichen. Die Stahlenergiepfähle bieten neben der Wärmegewinnung weitere Vorteile, da sie auch eine statische Funktion übernehmen und rückstandsfrei zurückgebaut werden können. Es werden analytische und numerische Berechnungen vorgestellt, um die thermischen Potenziale beider Systeme zu vergleichen. Außerdem wird ein Testaufbau gezeigt, bei dem Stahlenergiepfähle in zwei verschiedenen Längen mit vorhandenen gängigen Erdsonden verglichen werden können. Die Berechnungen zeigen einen deutlichen thermischen Mehrertrag zwischen 26 % und 148 % der Stahlenergiepfähle gegenüber dem Stand der Technik abhängig vom Erdreich. Die Messergebnisse zeigen einen thermischen Mehrertrag von über 100 %. Es lässt sich also signifikante Erdsondenlänge einsparen. Dabei ist zu beachten, dass sich damit der thermisch genutzte Bereich des Erdreichs reduziert, wodurch die thermische Regeneration und/oder das Langzeitverhalten des Erdreichs an Bedeutung gewinnt. Y1 - 2021 VL - 90. 2021 IS - 6 SP - 417 EP - 424 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Herrmann, Ulf A1 - Schwarzenbart, Marc A1 - Dittmann-Gabriel, Sören A1 - May, Martin T1 - Hochtemperatur-Wärmespeicher für die Strom- und Wärmewende JF - Solarzeitalter : Politik, Kultur und Ökonomie erneuerbarer Energien Y1 - 2019 SN - 0937-3802 VL - 31 IS - 2 SP - 18 EP - 23 ER - TY - JOUR A1 - Meyer, S. A1 - Hänel, Matthias A1 - Beeh, B. A1 - Dittmann-Gabriel, Sören A1 - Dluhosch, R. A1 - May, Martin A1 - Herrmann, Ulf A1 - [und 5 weitere], T1 - Multifunktionaler thermischer Stromspeicher für die Strom- und Wärmeversorgung der Industrie von morgen JF - ETG Journal / Energietechnische Gesellschaft im VDE (ETG) Y1 - 2020 SN - 2625-9907 VL - 2020 IS - 1 SP - 6 EP - 9 ER - TY - JOUR A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Döring, Bernd A1 - Göttsche, Joachim A1 - Reger, Vitali A1 - Kuhnhenne, Markus T1 - Net-exergetic, hydraulic and thermal optimization of coaxial heat exchangers using fixed flow conditions instead of fixed flow rates JF - Geothermal Energy N2 - Previous studies optimized the dimensions of coaxial heat exchangers using constant mass fow rates as a boundary condition. They show a thermal optimal circular ring width of nearly zero. Hydraulically optimal is an inner to outer pipe radius ratio of 0.65 for turbulent and 0.68 for laminar fow types. In contrast, in this study, fow conditions in the circular ring are kept constant (a set of fxed Reynolds numbers) during optimization. This approach ensures fxed fow conditions and prevents inappropriately high or low mass fow rates. The optimization is carried out for three objectives: Maximum energy gain, minimum hydraulic efort and eventually optimum net-exergy balance. The optimization changes the inner pipe radius and mass fow rate but not the Reynolds number of the circular ring. The thermal calculations base on Hellström’s borehole resistance and the hydraulic optimization on individually calculated linear loss of head coefcients. Increasing the inner pipe radius results in decreased hydraulic losses in the inner pipe but increased losses in the circular ring. The net-exergy diference is a key performance indicator and combines thermal and hydraulic calculations. It is the difference between thermal exergy fux and hydraulic efort. The Reynolds number in the circular ring is instead of the mass fow rate constant during all optimizations. The result from a thermal perspective is an optimal width of the circular ring of nearly zero. The hydraulically optimal inner pipe radius is 54% of the outer pipe radius for laminar fow and 60% for turbulent fow scenarios. Net-exergetic optimization shows a predominant infuence of hydraulic losses, especially for small temperature gains. The exact result depends on the earth’s thermal properties and the fow type. Conclusively, coaxial geothermal probes’ design should focus on the hydraulic optimum and take the thermal optimum as a secondary criterion due to the dominating hydraulics. Y1 - 2021 U6 - http://dx.doi.org/10.1186/s40517-021-00201-3 SN - 2195-9706 N1 - Corresponding author: Tobias Blanke VL - 9 IS - Article number: 19 PB - Springer CY - Berlin ER - TY - JOUR A1 - Göttsche, Joachim A1 - Alexopoulos, Spiros A1 - Dümmler, Andreas A1 - Maddineni, S. K. T1 - Multi-Mirror Array Calculations With Optical Error N2 - The optical performance of a 2-axis solar concentrator was simulated with the COMSOL Multiphysics® software. The concentrator consists of a mirror array, which was created using the application builder. The mirror facets are preconfigured to form a focal point. During tracking all mirrors are moved simultaneously in a coupled mode by 2 motors in two axes, in order to keep the system in focus with the moving sun. Optical errors on each reflecting surface were implemented in combination with the solar angular cone of ± 4.65 mrad. As a result, the intercept factor of solar radiation that is available to the receiver was calculated as a function of the transversal and longitudinal angles of incidence. In addition, the intensity distribution on the receiver plane was calculated as a function of the incidence angles. KW - solar process heat KW - concentrating collector KW - raytracing KW - point-focussing system Y1 - 2019 SP - 1 EP - 6 ER - TY - JOUR A1 - El Moussaoui, Noureddine A1 - Talbi, Sofian A1 - Atmane, Ilyas A1 - Kassmi, Khalil A1 - Schwarzer, Klemens A1 - Chayeb, Hamid A1 - Bachiri, Najib T1 - Feasibility of a new design of a Parabolic Trough Solar Thermal Cooker (PSTC) JF - Solar Energy N2 - In this article, we describe the structure, the functioning, and the tests of parabolic trough solar thermal cooker (PSTC). This oven is designed to meet the needs of rural residents, including Urban, which requires stable cooking temperatures above 200 °C. The cooking by this cooker is based on the concentration of the sun's rays on a glass vacuum tube and heating of the oil circulate in a big tube, located inside the glass tube. Through two small tubes, associated with large tube, the heated oil, rise and heats the pot of cooking pot containing the food to be cooked (capacity of 5 kg). This cooker is designed in Germany and extensively tested in Morocco for use by the inhabitants who use wood from forests. During a sunny day, having a maximum solar radiation around 720 W/m2 and temperature ambient around 26 °C, maximum temperatures recorded of the small tube, the large tube and the center of the pot are respectively: 370 °C, 270 °C and 260 °C. The cooking process with food at high (fries, ..), we show that the cooking oil temperature rises to 200 °C, after 1 h of heating, the cooking is done at a temperature of 120 °C for 20 min. These temperatures are practically stable following variations and decreases in the intensity of irradiance during the day. The comparison of these results with those of the literature shows an improvement of 30–50 % on the maximum value of the temperature with a heat storage that could reach 60 min of autonomy. All the results obtained show the good functioning of the PSTC and the feasibility of cooking food at high temperature (>200 °C). Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.solener.2020.03.079 SN - 0038-092X VL - 201 IS - Vol. 201 (May 2020) SP - 866 EP - 871 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Sattler, Johannes, Christoph A1 - Röger, Marc A1 - Schwarzbözl, Peter A1 - Buck, Reiner A1 - Macke, Ansgar A1 - Raeder, Christian A1 - Göttsche, Joachim T1 - Review of heliostat calibration and tracking control methods JF - Solar Energy N2 - Large scale central receiver systems typically deploy between thousands to more than a hundred thousand heliostats. During solar operation, each heliostat is aligned individually in such a way that the overall surface normal bisects the angle between the sun’s position and the aim point coordinate on the receiver. Due to various tracking error sources, achieving accurate alignment ≤1 mrad for all the heliostats with respect to the aim points on the receiver without a calibration system can be regarded as unrealistic. Therefore, a calibration system is necessary not only to improve the aiming accuracy for achieving desired flux distributions but also to reduce or eliminate spillage. An overview of current larger-scale central receiver systems (CRS), tracking error sources and the basic requirements of an ideal calibration system is presented. Leading up to the main topic, a description of general and specific terms on the topics heliostat calibration and tracking control clarifies the terminology used in this work. Various figures illustrate the signal flows along various typical components as well as the corresponding monitoring or measuring devices that indicate or measure along the signal (or effect) chain. The numerous calibration systems are described in detail and classified in groups. Two tables allow the juxtaposition of the calibration methods for a better comparison. In an assessment, the advantages and disadvantages of individual calibration methods are presented. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.solener.2020.06.030 VL - 207 SP - 110 EP - 132 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Reger, Vitali A1 - Kuhnhenne, Markus A1 - Ebbert, Thiemo A1 - Hachul, Helmut A1 - Blanke, Tobias A1 - Döring, Bernd T1 - Nutzung erneuerbarer Energien durch thermische Aktivierung von Komponenten aus Stahl JF - Stahlbau N2 - Die Versorgung von Neubauten soll möglichst weitgehend unabhängig von fossilen Energieträgern erfolgen. Erneuerbare Energien spielen dafür eine gewichtige Rolle. Eine gute Möglichkeit, erneuerbare Energien ohne viel zusätzlichen Aufwand nutzbar zu machen, ist, bereits vorhandenen Komponenten im Gebäude zusätzliche Funktionen zu geben. Hier kann bspw. die Fassade oder das Dach solarthermisch aktiviert oder durch Fotovoltaikmodule ergänzt werden. Auch Tiefgründungen können neben der statischen Funktion noch eine geothermische Funktion zur Aufnahme oder Abgabe von Wärme erhalten. Neben der Erzeugung bietet sich auch für die Verteilung der Wärme oder Kälte im Gebäude die Integration in Bauteile an. Hier kann bspw. der Boden durch eine Fußbodenheizung oder die Decke durch Deckenstrahlplatten aktiviert werden. Im Rahmen der Veröffentlichung wird auf die thermische Aktivierung von Stahlkomponenten eingegangen. Es wird eine Lösung vorgestellt, die vorgehängte hinterlüftete Stahlfassade (VHF) solarthermisch zu aktivieren. Außerdem werden zwei Möglichkeiten zur geothermischen Aktivierung von Tiefgründungen mittels Stahlpfählen gezeigt. Zuletzt wird ein System zur thermischen Aktivierung von Stahltrapezprofilen an der Decke erläutert, welches Wärme zuführen oder bei Bedarf abführen kann. Y1 - 2020 U6 - http://dx.doi.org/10.1002/stab.202000031 SN - 1437-1049 VL - 2020 IS - Volume 89, Issue 6512-519 SP - 512 EP - 519 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Herrmann, Ulf A1 - Schwarzenbart, Marc A1 - Dittmann-Gabriel, Sören T1 - Speicher statt Kohle. Integration thermischer Stromspeicher in vorhandene Kraftwerksstandorte JF - BWK : Das Energie-Fachmagazin Y1 - 2019 SN - 1436-4883 VL - 71 IS - 4 SP - 42 EP - 45 PB - Springer-VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Wolisz, Henryk A1 - Schütz, Thomas A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Kohrn, Markus A1 - Wesseling, Mark A1 - Müller, Dirk T1 - Cost optimal sizing of smart buildings' energy system components considering changing end-consumer electricity markets JF - Energy Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.energy.2017.06.025 VL - 137 SP - 715 EP - 728 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Reger, Vitali A1 - Kuhnhenne, Markus A1 - Hachul, Helmut A1 - Döring, Bernd A1 - Blanke, Tobias A1 - Göttsche, Joachim T1 - Plusenergiegebäude 2.0 in Stahlleichtbauweise JF - Stahlbau Y1 - 2019 U6 - http://dx.doi.org/10.1002/stab.201900034 SN - 1437-1049 (E-journal), 0038-9145 (print) VL - 88 IS - 6 SP - 522 EP - 528 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Puppe, Michael A1 - Giuliano, Stefano A1 - Frantz, Cathy A1 - Uhlig, Ralf A1 - Schumacher, Ralph A1 - Ibraheem, Wagdi A1 - Schmalz, Stefan A1 - Waldmann, Barbara A1 - Guder, Christoph A1 - Peter, Dennis A1 - Schwager, Christian A1 - Teixeira Boura, Cristiano José A1 - Alexopoulos, Spiros A1 - Spiegel, Michael A1 - Wortmann, Jürgen A1 - Hinrichs, Matthias A1 - Engelhard, Manfred A1 - Aust, Michael T1 - Techno-economic optimization of molten salt solar tower plants JF - AIP Conference Proceedings art.no. 040033 N2 - In this paper the results of a techno-economic analysis of improved and optimized molten salt solar tower plants (MSSTP plants) are presented. The potential improvements that were analyzed include different receiver designs, different designs of the HTF-system and plant control, increased molten salt temperatures (up to 640°C) and multi-tower systems. Detailed technological and economic models of the solar field, solar receiver and high temperature fluid system (HTF-system) were developed and used to find potential improvements compared to a reference plant based on Solar Two technology and up-to-date cost estimations. The annual yield model calculates the annual outputs and the LCOE of all variants. An improved external tubular receiver and improved HTF-system achieves a significant decrease of LCOE compared to the reference. This is caused by lower receiver cost as well as improvements of the HTF-system and plant operation strategy, significantly reducing the plant own consumption. A novel star receiver shows potential for further cost decrease. The cavity receiver concepts result in higher LCOE due to their high investment cost, despite achieving higher efficiencies. Increased molten salt temperatures seem possible with an adapted, closed loop HTF-system and achieve comparable results to the original improved system (with 565°C) under the given boundary conditions. In this analysis all multi tower systems show lower economic viability compared to single tower systems, caused by high additional cost for piping connections and higher cost of the receivers. REFERENCES Y1 - 2019 U6 - http://dx.doi.org/10.1063/1.5067069 VL - 2033 IS - Issue 1 PB - AIP Publishing CY - Melville, NY ER -