TY - JOUR A1 - Feldmann, Markus A1 - Döring, Bernd A1 - Kuhnhenne, Markus A1 - Sedlacek, Gerhard T1 - Zum Thema “Nachhaltigkeit” in der Stahlbauindustrie JF - Stahlbau Y1 - 2008 SN - 0038-9145 N1 - Printausg. in der Bibliothek Bayernallee vorhanden: 13 Z 181 VL - Vol. 77 IS - Iss. 10 SP - 713 EP - 720 ER - TY - JOUR A1 - Hagenkamp, Markus A1 - Blanke, Tobias A1 - Döring, Bernd T1 - Thermoelectric building temperature control: a potential assessment JF - International Journal of Energy and Environmental Engineering N2 - This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants. Y1 - 2021 U6 - http://dx.doi.org/10.1007/s40095-021-00424-x N1 - Corresponding author: Markus Hagenkamp VL - 13 SP - 241 EP - 254 PB - Springer CY - Berlin ER - TY - JOUR A1 - Döring, Bernd A1 - Hechler, O. A1 - Weber, F. A1 - Sedlacek, Gerhard T1 - Thermische Aktivierung von Fertigteildecken JF - HLH Lüftung/Klima, Heizung/Sanitär, Gebäudetechnik Y1 - 2004 SN - 1436-5103 N1 - Printausg. in der Bibliothek Bayernallee vorhanden: 13 Z 739 VL - Jg. 55 IS - Nr. 5 SP - 24 EP - 35 ER - TY - JOUR A1 - Döring, Bernd A1 - Kendrick, C. A1 - Lawson, R. M. T1 - Thermal capacity of composite floor slabs JF - Energy and buildings Y1 - 2013 SN - 1872-6178 (E-Journal); 0378-7788 (Print) VL - Vol. 67 SP - 531 EP - 539 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Döring, Bernd A1 - Reger, Vitali A1 - Kuhnhenne, Markus A1 - Feldmann, Markus A1 - Kesti, Jyrki A1 - Lawson, Mark A1 - Botti, Andrea T1 - Steel solutions for enabling zero-energy buildings JF - Steel Construction - Design and Research Y1 - 2015 U6 - http://dx.doi.org/10.1002/stco.201510029 SN - 1867-0539 N1 - The 13th Nordic Steel Construction Conference, Tampere, 2015 (NSCC-2015) VL - 8 IS - 3 SP - 194 EP - 200 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Kuck, Herbert A1 - Döring, Bernd T1 - Regenerative Energien in Landesbauten : Land NRW unterstützt Einsatz erneuerbarer Energien 1997 mit 15 Mio. DM JF - Die Bauverwaltung mit Bauamt und Gemeindebau Y1 - 1997 SN - 0005-6847 VL - Bd. 70 IS - H. 8 SP - 384 EP - 386 ER - TY - JOUR A1 - Reger, Vitali A1 - Kuhnhenne, Markus A1 - Hachul, Helmut A1 - Döring, Bernd A1 - Blanke, Tobias A1 - Göttsche, Joachim T1 - Plusenergiegebäude 2.0 in Stahlleichtbauweise JF - Stahlbau Y1 - 2019 U6 - http://dx.doi.org/10.1002/stab.201900034 SN - 1437-1049 (E-journal), 0038-9145 (print) VL - 88 IS - 6 SP - 522 EP - 528 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Döring, Bernd A1 - Feldmann, Markus A1 - Kuhnhenne, Markus A1 - Müller, Dirk T1 - Phasenwechselmaterial im Metallleichtbau zur Optimierung von Energieeffizienz und sommerlicher Raumtemperatur JF - Stahlbau Y1 - 2011 SN - 1437-1049 (E-Journal); 0038-9145 (Print) VL - Vol. 80 IS - Iss. 9 SP - 666 EP - 672 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Reger, V. A1 - Döring, Bernd A1 - Kuhnhenne, M. T1 - Passive und aktive Maßnahmen zur Flächenkühlung im Stahl(leicht)bau JF - Bauingenieur N2 - Mit steigenden Dämmstandards und höheren Komfortanforderungen der Nutzer gerät die Problematik der sommerlichen Überhitzung zunehmend in den Fokus. Um die Überhitzung möglichst gering zu halten, sind Maßnahmen und Lösungen zu entwickeln, die den potenziellen Kühlbedarf eines Gebäudes vermeiden sowie reduzieren. Im Rahmen des europäischen Forschungsprojektes BATIMASS wurden Techniken untersucht, die die sommerliche Raumtemperatur ohne zusätzliche Kühlung (passiv) oder aber mit energieeffizienter wasserbasierter Flächenkühlung (aktiv) reduzieren und die besonders für Gebäude in Stahl(leicht)bauweise geeignet sind. Dafür wurde die Methodik der thermisch äquivalenten Decke weiterentwickelt, um das thermische Verhalten von Profilblechdecken in Gebäuden für beide Lösungsansätze analysieren zu können. Darüber hinaus wurde der Einsatz von Phasenwechselmaterial (PCM) zur Steigerung der Speicherfähigkeit von leichten Decken mit besonders geringer thermischer Masse in Simulationen sowie im Labor untersucht und bewertet. Y1 - 2016 U6 - http://dx.doi.org/10.37544/0005-6650-2016-07-08-63 SN - 0005-6650 N1 - gedruckt in der Bereichsbibliothek Bayernallee unter der Signatur 13 Z 049 VL - 91 IS - Jul/Aug SP - 309 EP - 316 PB - VDI Fachmedien CY - Düsseldorf ER - TY - JOUR A1 - Reger, Vitali A1 - Kuhnhenne, Markus A1 - Ebbert, Thiemo A1 - Hachul, Helmut A1 - Blanke, Tobias A1 - Döring, Bernd T1 - Nutzung erneuerbarer Energien durch thermische Aktivierung von Komponenten aus Stahl JF - Stahlbau N2 - Die Versorgung von Neubauten soll möglichst weitgehend unabhängig von fossilen Energieträgern erfolgen. Erneuerbare Energien spielen dafür eine gewichtige Rolle. Eine gute Möglichkeit, erneuerbare Energien ohne viel zusätzlichen Aufwand nutzbar zu machen, ist, bereits vorhandenen Komponenten im Gebäude zusätzliche Funktionen zu geben. Hier kann bspw. die Fassade oder das Dach solarthermisch aktiviert oder durch Fotovoltaikmodule ergänzt werden. Auch Tiefgründungen können neben der statischen Funktion noch eine geothermische Funktion zur Aufnahme oder Abgabe von Wärme erhalten. Neben der Erzeugung bietet sich auch für die Verteilung der Wärme oder Kälte im Gebäude die Integration in Bauteile an. Hier kann bspw. der Boden durch eine Fußbodenheizung oder die Decke durch Deckenstrahlplatten aktiviert werden. Im Rahmen der Veröffentlichung wird auf die thermische Aktivierung von Stahlkomponenten eingegangen. Es wird eine Lösung vorgestellt, die vorgehängte hinterlüftete Stahlfassade (VHF) solarthermisch zu aktivieren. Außerdem werden zwei Möglichkeiten zur geothermischen Aktivierung von Tiefgründungen mittels Stahlpfählen gezeigt. Zuletzt wird ein System zur thermischen Aktivierung von Stahltrapezprofilen an der Decke erläutert, welches Wärme zuführen oder bei Bedarf abführen kann. Y1 - 2020 U6 - http://dx.doi.org/10.1002/stab.202000031 SN - 1437-1049 VL - 2020 IS - Volume 89, Issue 6512-519 SP - 512 EP - 519 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Döring, Bernd A1 - Göttsche, Joachim A1 - Reger, Vitali A1 - Kuhnhenne, Markus T1 - Net-exergetic, hydraulic and thermal optimization of coaxial heat exchangers using fixed flow conditions instead of fixed flow rates JF - Geothermal Energy N2 - Previous studies optimized the dimensions of coaxial heat exchangers using constant mass fow rates as a boundary condition. They show a thermal optimal circular ring width of nearly zero. Hydraulically optimal is an inner to outer pipe radius ratio of 0.65 for turbulent and 0.68 for laminar fow types. In contrast, in this study, fow conditions in the circular ring are kept constant (a set of fxed Reynolds numbers) during optimization. This approach ensures fxed fow conditions and prevents inappropriately high or low mass fow rates. The optimization is carried out for three objectives: Maximum energy gain, minimum hydraulic efort and eventually optimum net-exergy balance. The optimization changes the inner pipe radius and mass fow rate but not the Reynolds number of the circular ring. The thermal calculations base on Hellström’s borehole resistance and the hydraulic optimization on individually calculated linear loss of head coefcients. Increasing the inner pipe radius results in decreased hydraulic losses in the inner pipe but increased losses in the circular ring. The net-exergy diference is a key performance indicator and combines thermal and hydraulic calculations. It is the difference between thermal exergy fux and hydraulic efort. The Reynolds number in the circular ring is instead of the mass fow rate constant during all optimizations. The result from a thermal perspective is an optimal width of the circular ring of nearly zero. The hydraulically optimal inner pipe radius is 54% of the outer pipe radius for laminar fow and 60% for turbulent fow scenarios. Net-exergetic optimization shows a predominant infuence of hydraulic losses, especially for small temperature gains. The exact result depends on the earth’s thermal properties and the fow type. Conclusively, coaxial geothermal probes’ design should focus on the hydraulic optimum and take the thermal optimum as a secondary criterion due to the dominating hydraulics. Y1 - 2021 U6 - http://dx.doi.org/10.1186/s40517-021-00201-3 SN - 2195-9706 N1 - Corresponding author: Tobias Blanke VL - 9 IS - Article number: 19 PB - Springer CY - Berlin ER - TY - JOUR A1 - Blanke, Tobias A1 - Reger, Vitali A1 - Döring, Bernd A1 - Göttsche, Joachim A1 - Kuhnhenne, Markus T1 - Koaxiale Stahlenergiepfähle JF - Stahlbau N2 - Ein entscheidender Teil der Energiewende ist die Wärmewende im Gebäudesektor. Ein Schlüsselelement sind hier Wärmepumpen. Diese benötigen eine Wärmequelle, der sie Energie entziehen können, um sie auf ein höheres Temperaturniveau zu transformieren. Diese Wärmequelle kann bspw. das Erdreich sein, dessen Wärme durch Erdsonden erschlossen werden kann. In diesem Beitrag werden in Stahlpfähle integrierte Koaxialsonden mit dem Stand der Technik von Erdsonden gleichen Durchmessers bezüglich ihrer thermischen Leistungsmerkmale verglichen. Die Stahlenergiepfähle bieten neben der Wärmegewinnung weitere Vorteile, da sie auch eine statische Funktion übernehmen und rückstandsfrei zurückgebaut werden können. Es werden analytische und numerische Berechnungen vorgestellt, um die thermischen Potenziale beider Systeme zu vergleichen. Außerdem wird ein Testaufbau gezeigt, bei dem Stahlenergiepfähle in zwei verschiedenen Längen mit vorhandenen gängigen Erdsonden verglichen werden können. Die Berechnungen zeigen einen deutlichen thermischen Mehrertrag zwischen 26 % und 148 % der Stahlenergiepfähle gegenüber dem Stand der Technik abhängig vom Erdreich. Die Messergebnisse zeigen einen thermischen Mehrertrag von über 100 %. Es lässt sich also signifikante Erdsondenlänge einsparen. Dabei ist zu beachten, dass sich damit der thermisch genutzte Bereich des Erdreichs reduziert, wodurch die thermische Regeneration und/oder das Langzeitverhalten des Erdreichs an Bedeutung gewinnt. Y1 - 2021 VL - 90. 2021 IS - 6 SP - 417 EP - 424 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Hegger, Josef A1 - Claßen, Martin A1 - Feldmann, Markus A1 - Döring, Bernd A1 - Schaumann, Peter A1 - Sothmann, Jörg A1 - Bohne, Dirk A1 - Hargus, Steen A1 - Barben, Daniel A1 - Aarden, Erik A1 - Schielke, Sabine T1 - Integrierte und nachhaltigkeitsorientierte Deckensysteme im Stahl- und Verbundbau JF - Stahlbau Y1 - 2011 SN - 1437-1049 (E-Journal); 0038-9145 (Print) VL - Vol. 80 IS - Iss. 10 SP - 728 EP - 733 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Kuhnhenne, Markus A1 - Reger, Vitali A1 - Pyschny, Dominik A1 - Döring, Bernd T1 - Influence of airtightness of steel sandwich panel joints on heat losses JF - E3S Web of Conferences 12th Nordic Symposium on Building Physics (NSB 2020) N2 - Energy saving ordinances requires that buildings must be designed in such a way that the heat transfer surface including the joints is permanently air impermeable. The prefabricated roof and wall panels in lightweight steel constructions are airtight in the area of the steel covering layers. The sealing of the panel joints contributes to fulfil the comprehensive requirements for an airtight building envelope. To improve the airtightness of steel sandwich panels, additional sealing tapes can be installed in the panel joint. The influence of these sealing tapes was evaluated by measurements carried out by the RWTH Aachen University - Sustainable Metal Building Envelopes. Different installation situations were evaluated by carrying out airtightness tests for different joint distances. In addition, the influence on the heat transfer coefficient was also evaluated using the Finite Element Method (FEM). The combination of obtained air volume flow and transmission losses enables to create an "effective heat transfer coefficient" due to transmission and infiltration. This summarizes both effects in one value and is particularly helpful for approximate calculations on energy efficiency. Y1 - 2020 U6 - http://dx.doi.org/10.1051/e3sconf/202017205008 VL - 172 IS - Art. 05008 PB - EDP Sciences CY - Les Ulis ER - TY - JOUR A1 - Kuhnhenne, Markus A1 - Döring, Bernd A1 - Feldmann, Markus T1 - Grundsätze und Lösungen zur Wärmebrückenreduktion im Metallleichtbau JF - Stahlbau N2 - Die Anforderungen an das energiesparende Bauen sind mit der Einführung der Energieeinsparverordnung (EnEV) 2009 auch im Industrie- und Gewerbebau deutlich verschärft worden. Einen wesentlichen Beitrag zur Energieeinsparung liefert die Minimierung des Transmissionswärmetransfers. Analysiert man Gebäudehüllen in Metallleichtbauweise stellt man fest, dass eine Erhöhung der Wärmedämmstärke allein noch nicht zielführend ist, zusätzlich sind Wärmebrückeneffekte zu berücksichtigen und deren Einflüsse auf die Wärmetransmission zu reduzieren. Neben der Bedeutung für die Energieeinsparung ist eine wärmetechnisch optimierte Detailausbildung auch erforderlich, um einen ausreichenden Feuchteschutz (Vermeidung von Tauwasser und Schimmelpilz) zu realisieren und so Schäden zu vermeiden. Ein wichtiges Hilfsmittel stellt hierzu der vom Industrieverband für Bausysteme im Metallleichtbau (IFBS) herausgegebene Wärmebrückenatlas der Metall-Sandwichbauweise dar. Y1 - 2010 U6 - http://dx.doi.org/10.1002/stab.201001330 SN - 1437-1049 (E-Journal); 0038-9145 (Print) VL - 79 IS - 5 SP - 345 EP - 355 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Pyschny, D. A1 - Döring, Bernd A1 - Feldmann, M. T1 - Ermittlung der thermischen Leistungsfähigkeit des neuartigen multifunktionalen Verbunddeckensystems InaDeck JF - Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen Y1 - 2014 SN - 0005-6650 N1 - Printausgabe in der Bibliothek Bayernallee vorhanden: 13 Z 049-2014 VL - 89 IS - 3 SP - 116 EP - 124 PB - VDI Fachmedien CY - Düsseldorf ER - TY - JOUR A1 - Hegger, Josef A1 - Claßen, Martin A1 - Schaumann, Peter A1 - Sothmann, Jörg A1 - Feldmann, Markus A1 - Döring, Bernd T1 - Entwicklung einer integrierten Verbunddecke für nachhaltige Stahlbauten JF - Stahlbau Y1 - 2013 SN - 1437-1049 (E-Journal); 0038-9145 (Print) VL - Vol. 82 IS - Iss. 1 SP - 11 EP - 17 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Ziller, Claudia A1 - Döring, Bernd T1 - Doppelfassaden - vom Experimentalmodell zum Massanzug JF - TAB Technik am Bau Y1 - 2004 SN - 0341-2032 VL - Bd. 35 IS - H. 12 SP - 58 EP - 63 ER - TY - JOUR A1 - Kuhnhenne, Markus A1 - Döring, Bernd A1 - Kocker, Ronald A1 - Pyschny, Dominik A1 - Feldmann, Markus T1 - Die Ökobilanz als Baustein der Nachhaltigkeitsbewertung im Industrie- und Gewerbebau JF - Stahlbau N2 - Im Herbst 2009 wurde das “Deutsche Gütesiegel Nachhaltiges Bauen” für die Gebäudetypen Industriebauten und Handelsbauten offiziell vorgestellt. Die Ökobilanz als wichtiger Baustein der Nachhaltigkeitsbewertung wird somit auch im Industrie- und Gewerbebau zukünftig stark an Bedeutung gewinnen. Der vorliegende Beitrag beinhaltet einen Vergleich der Umweltleistung verschiedener Bauweisen des Industrie- und Gewerbebaus, die durch die Ökobilanzierung quantifizierbar wird, anhand von momentan verfügbaren Daten und Methoden. Es werden ausgewählte Ergebnisse sowie vorhandene Unsicherheiten und daraus resultierender Forschungsbedarf aufgezeigt. Y1 - 2010 U6 - http://dx.doi.org/10.1002/stab.201001336 SN - 1437-1049 (E-Journal); 0038-9145 (Print) VL - 79 IS - 6 SP - 439 EP - 447 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Thiel, Dieter A1 - Döring, Bernd T1 - Dezentrale Raumklimatisierung durch die Fassade JF - TAB Technik am Bau Y1 - 2001 SN - 0341-2032 VL - Bd. 32 IS - H. 3 SP - 67 EP - 76 ER -