TY - CHAP A1 - Pohle-Fröhlich, Regina A1 - Dalitz, Christoph A1 - Richter, Charlotte A1 - Hahnen, Tobias A1 - Stäudle, Benjamin A1 - Albracht, Kirsten T1 - Estimation of muscle fascicle orientation in ultrasonic images T2 - VISIGRAPP 2020 - Proceedings of the 15th International Joint Conference on Computer Vision, Imaging and Computer Graphics Theory and Applications, 5 Y1 - 2020 SP - 79 EP - 86 ER - TY - CHAP A1 - Baader, Fabian A1 - Keller, Denis A1 - Lehmann, Raphael A1 - Gerber, Lukas A1 - Reiswich, Martin A1 - Dachwald, Bernd A1 - Förstner, Roger T1 - Operating melting probes for ice penetration under sublimation conditions and in reduced gravity on a sounding rocket T2 - Proceedings of the 24th ESA Symposium on European Rocket and Balloon Programmes and related Research Y1 - 2019 SN - 0379-6566 N1 - 24th PAC Symposium 2019 ER - TY - CHAP A1 - Savitskaya, Irina S. A1 - Kistaubayeva, Aida S. A1 - Akimbekov, Nuraly S. A1 - Digel, Ilya A1 - Zhubanova, Azhar A. T1 - Performance of Bio-Composite Carbonized Materials in Probiotic Applications T2 - World Academy of Science, Engineering and Technology International Journal of Biotechnology and Bioengineering Y1 - 2013 VL - 7 IS - 7 SP - 685 EP - 689 ER - TY - CHAP A1 - Grundmann, Jan Thimo A1 - Bauer, Wlademar A1 - Borchers, Kai A1 - Dumont, Etienne A1 - Grimm, Christian D. A1 - Ho, Tra-Mi A1 - Jahnke, Rico A1 - Koch, Aaron D. A1 - Lange, Caroline A1 - Maiwald, Volker A1 - Meß, Jan-Gerd A1 - Mikulz, Eugen A1 - Quantius, Dominik A1 - Reershemius, Siebo A1 - Renger, Thomas A1 - Sasaki, Kaname A1 - Seefeldt, Patric A1 - Spietz, Peter A1 - Spröwitz, Tom A1 - Sznajder, Maciej A1 - Toth, Norbert A1 - Ceriotti, Matteo A1 - McInnes, Colin A1 - Peloni, Alessandro A1 - Biele, Jens A1 - Krause, Christian A1 - Dachwald, Bernd A1 - Hercik, David A1 - Lichtenheldt, Roy A1 - Wolff, Friederike A1 - Koncz, Alexander A1 - Pelivan, Ivanka A1 - Schmitz, Nicole A1 - Boden, Ralf A1 - Riemann, Johannes A1 - Seboldt, Wolfgang A1 - Wejmo, Elisabet A1 - Ziach, Christian A1 - Mikschl, Tobias A1 - Montenegro, Sergio A1 - Ruffer, Michael A1 - Cordero, Federico A1 - Tardivel, Simon T1 - Solar sails for planetary defense & high-energy missions T2 - IEEE Aerospace Conference Proceedings N2 - 20 years after the successful ground deployment test of a (20 m) 2 solar sail at DLR Cologne, and in the light of the upcoming U.S. NEAscout mission, we provide an overview of the progress made since in our mission and hardware design studies as well as the hardware built in the course of our solar sail technology development. We outline the most likely and most efficient routes to develop solar sails for useful missions in science and applications, based on our developed `now-term' and near-term hardware as well as the many practical and managerial lessons learned from the DLR-ESTEC Gossamer Roadmap. Mission types directly applicable to planetary defense include single and Multiple NEA Rendezvous ((M)NR) for precursor, monitoring and follow-up scenarios as well as sail-propelled head-on retrograde kinetic impactors (RKI) for mitigation. Other mission types such as the Displaced L1 (DL1) space weather advance warning and monitoring or Solar Polar Orbiter (SPO) types demonstrate the capability of near-term solar sails to achieve asteroid rendezvous in any kind of orbit, from Earth-coorbital to extremely inclined and even retrograde orbits. Some of these mission types such as SPO, (M)NR and RKI include separable payloads. For one-way access to the asteroid surface, nanolanders like MASCOT are an ideal match for solar sails in micro-spacecraft format, i.e. in launch configurations compatible with ESPA and ASAP secondary payload platforms. Larger landers similar to the JAXA-DLR study of a Jupiter Trojan asteroid lander for the OKEANOS mission can shuttle from the sail to the asteroids visited and enable multiple NEA sample-return missions. The high impact velocities and re-try capability achieved by the RKI mission type on a final orbit identical to the target asteroid's but retrograde to its motion enables small spacecraft size impactors to carry sufficient kinetic energy for deflection. Y1 - 2019 U6 - http://dx.doi.org/10.1109/AERO.2019.8741900 N1 - AERO 2019; Big Sky; United States; 2 March 2019 through 9 March 2019 SP - 1 EP - 21 ER - TY - CHAP A1 - Waldmann, Christoph A1 - Vera, Jean-Pierre de A1 - Dachwald, Bernd A1 - Strasdeit, Henry A1 - Sohl, Frank A1 - Hanff, Hendrik A1 - Kowalski, Julia A1 - Heinen, Dirk A1 - Macht, Sabine A1 - Bestmann, Ulf A1 - Meckel, Sebastian A1 - Hildebrandt, Marc A1 - Funke, Oliver A1 - Gehrt, Jan-Jöran T1 - Search for life in ice-covered oceans and lakes beyond Earth T2 - 2018 IEEE/OES Autonomous Underwater Vehicle Workshop, Proceedings November 2018, Article number 8729761 N2 - The quest for life on other planets is closely connected with the search for water in liquid state. Recent discoveries of deep oceans on icy moons like Europa and Enceladus have spurred an intensive discussion about how these waters can be accessed. The challenge of this endeavor lies in the unforeseeable requirements on instrumental characteristics both with respect to the scientific and technical methods. The TRIPLE/nanoAUV initiative is aiming at developing a mission concept for exploring exo-oceans and demonstrating the achievements in an earth-analogue context, exploring the ocean under the ice shield of Antarctica and lakes like Dome-C on the Antarctic continent. KW - Planetary exploration KW - Jupiter KW - ice moons KW - underwater vehicle KW - Antarctica Y1 - 2018 U6 - http://dx.doi.org/10.1109/AUV.2018.8729761 ER - TY - CHAP A1 - Blum, Yannik A1 - Albanna, Walid A1 - Benninghaus, Anne A1 - Kotliar, Konstantin ED - Staat, Manfred ED - Erni, Daniel T1 - Vasomotion in retinal vessels of patients presenting post hemorrhagic hydrocephalus following subarachnoid hemorrhage T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - Clearance of blood components and fluid drainage play a crucial role in subarachnoid hemorrhage (SAH) and post hemorrhagic hydrocephalus (PHH). With the involvement of interstitial fluid (ISF) and cerebrospinal fluid (CSF), two pathways for the clearance of fluid and solutes in the brain are proposed. Starting at the level of capillaries, flow of ISF follows along the basement membranes in the walls of cerebral arteries out of the parenchyma to drain into the lymphatics and CSF [1]–[3]. Conversely, it is shown that CSF enters the parenchyma between glial and pial basement membranes of penetrating arteries [4]–[6]. Nevertheless, the involved structures and the contribution of either flow pathway to fluid balance between the subarachnoid space and interstitial space remains controversial. Low frequency oscillations in vascular tone are referred to as vasomotion and corresponding vasomotion waves are modeled as the driving force for flow of ISF out of the parenchyma [7]. Retinal vessel analysis (RVA) allows non-invasive measurement of retinal vessel vasomotion with respect to diameter changes [8]. Thus, the aim of the study is to investigate vasomotion in RVA signals of SAH and PHH patients. Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 38 EP - 39 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Zingsheim, Jonas A1 - Grimmer, Timo A1 - Ortner, Marion A1 - Schmaderer, Christoph A1 - Hauser, Christine A1 - Kotliar, Konstantin ED - Staat, Manfred ED - Erni, Daniel T1 - Recognition of subjects with mild cognitive impairment (MCI) by the use of retinal arterial vessels. T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 36 EP - 37 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Azar, Fouad A1 - Digel, Ilya ED - Staat, Manfred ED - Erni, Daniel T1 - Utilization of fluorescence spectroscopy and neural networks in clinical analysis T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - Fluorescence topography of human urine in combination with learning algorithms can provide a variant pattern recognition method in analytical clinical chemistry and, eventually, diagnosis. Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 40 EP - 41 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Bayer, Robin A1 - Hescheler, Jürgen A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül ED - Staat, Manfred ED - Erni, Daniel T1 - Treating arterial hypertension in a cell culture well T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH AachenW N2 - Hypertension describes the pathological increase of blood pressure, which is most commonly associated with the increase of vascular wall stiffness [1]. Referring to the “Deutsche Bluthochdruck Liga” this pathology shows a growing trend in our aging society. In order to find novel pharmacological and probably personalized treatments, we want to present a functional approach to study biomechanical properties of a human aortic vascular model. In this method review we will give an overview of recent studies which were carried out with the CellDrum technology [2] and underline the added value to already existing standard procedures known from the field of physiology. Herein described CellDrum technology is a system to measure functional mechanical properties of cell monolayers and thin tissue constructs in-vitro. Additionally, the CellDrum enables to elucidate the mechanical response of cells to pharmacological drugs, toxins and vasoactive agents. Due to its highly flexible polymer support, cells can also be mechanically stimulated by steady and cyclic biaxial stretching. Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 5 EP - 6 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Raman, Aravind Hariharan A1 - Jung, Alexander A1 - Horváth, András A1 - Becker, Nadine A1 - Staat, Manfred ED - Staat, Manfred ED - Erni, Daniel T1 - Modification of a computer model of human stem cell-derived cardiomyocyte electrophysiology based on Patch-Clamp measurements T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - Human induced pluripotent stem cells (hiPSCs) have shown to be promising in disease studies and drug screenings [1]. Cardiomyocytes derived from hiPSCs have been extensively investigated using patch-clamping and optical methods to compare their electromechanical behaviour relative to fully matured adult cells. Mathematical models can be used for translating findings on hiPSCCMs to adult cells [2] or to better understand the mechanisms of various ion channels when a drug is applied [3,4]. Paci et al. (2013) [3] developed the first model of hiPSC-CMs, which they later refined based on new data [3]. The model is based on iCells® (Fujifilm Cellular Dynamics, Inc. (FCDI), Madison WI, USA) but major differences among several cell lines and even within a single cell line have been found and motivate an approach for creating sample-specific models. We have developed an optimisation algorithm that parameterises the conductances (in S/F=Siemens/Farad) of the latest Paci et al. model (2018) [5] using current-voltage data obtained in individual patch-clamp experiments derived from an automated patch clamp system (Patchliner, Nanion Technologies GmbH, Munich). Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 10 EP - 11 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Hunker, Jan A1 - Jung, Alexander A1 - Goßmann, Matthias A1 - Linder, Peter A1 - Staat, Manfred ED - Staat, Manfred ED - Erni, Daniel T1 - Development of a tool to analyze the conduction speed in microelectrode array measurements of cardiac tissue T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - The discovery of human induced pluripotent stem cells reprogrammed from somatic cells [1] and their ability to differentiate into cardiomyocytes (hiPSC-CMs) has provided a robust platform for drug screening [2]. Drug screenings are essential in the development of new components, particularly for evaluating the potential of drugs to induce life-threatening pro-arrhythmias. Between 1988 and 2009, 14 drugs have been removed from the market for this reason [3]. The microelectrode array (MEA) technique is a robust tool for drug screening as it detects the field potentials (FPs) for the entire cell culture. Furthermore, the propagation of the field potential can be examined on an electrode basis. To analyze MEA measurements in detail, we have developed an open-source tool. Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 7 EP - 8 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Grundmann, Jan Thimo A1 - Bauer, Waldemar A1 - Borchers, Kai A1 - Dumont, Etienne A1 - Grimm, Christian D. A1 - Ho, Tra-Mi A1 - Jahnke, Rico A1 - Lange, Caroline A1 - Maiwald, Volker A1 - Mikulz, Eugen A1 - Quantius, Dominik A1 - Reershemius, Siebo A1 - Renger, Thomas A1 - Riemann, Johannes A1 - Sasaki, Kaname A1 - Seefeldt, Patric A1 - Spietz, Peter A1 - Spröwitz, Tom A1 - Toth, Norbert A1 - Wejmo, Elisabet A1 - Biele, Jens A1 - Krause, Christian A1 - Cerotti, Matteo A1 - Peloni, Alessandro A1 - Dachwald, Bernd T1 - Small Spacecraft Solar Sailing for Small Solar System Body Multiple Rendezvous and Landing T2 - 2018 IEEE Aerospace Conference : 3-10 March 2018 Y1 - 2018 SN - 978-1-5386-2014-4 ER - TY - CHAP A1 - Richter, Charlotte A1 - Braunstein, Bjoern A1 - Stäudle, Benjamin A1 - Attias, Julia A1 - Suess, Alexander A1 - Weber, T. A1 - Rittweger, Joern A1 - Green, David A. A1 - Albracht, Kirsten T1 - In vivo fascicle length of the gastrocnemius muscle during walking in simulated martian gravity using two different body weight support devices T2 - 23rd Annual Congress of the European College of Sport Science, Dublin, Irland Y1 - 2018 ER - TY - CHAP A1 - Marinova, V. A1 - Kerroumi, I. A1 - Lintermann, A. A1 - Göbbert, J.H. A1 - Moulinec, C. A1 - Rible, S. A1 - Fournier, Y. A1 - Behbahani, Mehdi T1 - Numerical Analysis of the FDA Centrifugal Blood Pump T2 - NIC Symposium 2016 Y1 - 2016 SN - 978-3-95806-109-5 SP - 355 EP - 364 ER - TY - CHAP A1 - Behbahani, Mehdi A1 - Rible, Sebastian A1 - Moulinec, Charles A1 - Fournier, Yvan A1 - Nicolai, Mike A1 - Crosetto, Paolo T1 - Simulation of the FDA Centrifugal Blood Pump Using High Performance Computing T2 - World Academy of Science, Engineering and Technology International Journal of Mechanical and Mechatronics Engineering Y1 - 2015 VL - 9 IS - 5 ER - TY - CHAP A1 - Behbahani, Mehdi T1 - An Experimental Study of Thrombocyte Reactions in Response to Biomaterial Surfaces and Varying Shear Stress T2 - Proceedings of the International Conference on Biomedical Engineering and Systems Prague, Czech Republic, August 14-15, 2014 Y1 - 2014 SP - Paper 125 ER - TY - CHAP A1 - Kahmann, Stephanie Lucina A1 - Uschok, Stephan A1 - Wegmann, Kilian A1 - Müller, Lars-P. A1 - Staat, Manfred T1 - Biomechanical multibody model with refined kinematics of the elbow T2 - 6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK N2 - The overall objective of this study is to develop a new external fixator, which closely maps the native kinematics of the elbow to decrease the joint force resulting in reduced rehabilitation time and pain. An experimental setup was designed to determine the native kinematics of the elbow during flexion of cadaveric arms. As a preliminary study, data from literature was used to modify a published biomechanical model for the calculation of the joint and muscle forces. They were compared to the original model and the effect of the kinematic refinement was evaluated. Furthermore, the obtained muscle forces were determined in order to apply them in the experimental setup. The joint forces in the modified model differed slightly from the forces in the original model. The muscle force curves changed particularly for small flexion angles but their magnitude for larger angles was consistent. Y1 - 2018 ER - TY - CHAP A1 - Tran, Ngoc Trinh A1 - Matthies, Hermann G. A1 - Stavroulakis, Georgios Eleftherios A1 - Staat, Manfred T1 - Direct plastic structural design by chance constrained programming T2 - 6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK N2 - We propose a stochastic programming method to analyse limit and shakedown of structures under random strength with lognormal distribution. In this investigation a dual chance constrained programming algorithm is developed to calculate simultaneously both the upper and lower bounds of the plastic collapse limit or the shakedown limit. The edge-based smoothed finite element method (ES-FEM) using three-node linear triangular elements is used. Y1 - 2018 ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Staat, Manfred ED - Fernandes, P.R. ED - Tavares, J. M. T1 - Pectopexy to repair vaginal vault prolapse: a finite element approach T2 - Proceedings CMBBE 2018 N2 - The vaginal prolapse after hysterectomy (removal of the uterus) is often associated with the prolapse of the vaginal vault, rectum, bladder, urethra or small bowel. Minimally invasive surgery such as laparoscopic sacrocolpopexy and pectopexy are widely performed for the treatment of the vaginal prolapse with weakly supported vaginal vault after hysterectomy using prosthetic mesh implants to support (or strengthen) lax apical ligaments. Implants of different shape, size and polymers are selected depending on the patient’s anatomy and the surgeon’s preference. In this computational study on pectopexy, DynaMesh®-PRP soft, GYNECARE GYNEMESH® PS Nonabsorbable PROLENE® soft and Ultrapro® are tested in a 3D finite element model of the female pelvic floor. The mesh model is implanted into the extraperitoneal space and sutured to the vaginal stump with a bilateral fixation to the iliopectineal ligament at both sides. Numerical simulations are conducted at rest, after surgery and during Valsalva maneuver with weakened tissues modeled by reduced tissue stiffness. Tissues and prosthetic meshes are modeled as incompressible, isotropic hyperelastic materials. The positions of the organs are calculated with respect to the pubococcygeal line (PCL) for female pelvic floor at rest, after repair and during Valsalva maneuver using the three meshes. Y1 - 2018 N1 - 15th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering and 3rd Conference on Imaging and Visualization. CMBBE 2018. 26-29 March 2018, Lisbon, Portugal ER - TY - CHAP A1 - Grundmann, Jan Thimo A1 - Meß, Jan-Gerd A1 - Biele, Jens A1 - Seefeldt, Patric A1 - Dachwald, Bernd A1 - Spietz, Peter A1 - Grimm, Christian D. A1 - Spröwitz, Tom A1 - Lange, Caroline A1 - Ulamec, Stephan T1 - Small spacecraft in small solar system body applications T2 - IEEE Aerospace Conference 2017, Big Sky, Montana, USA Y1 - 2017 SN - 978-1-5090-1613-6 U6 - http://dx.doi.org/10.1109/AERO.2017.7943626 SP - 1 EP - 20 ER -