TY - CHAP A1 - Usai, Pierpaolo A1 - Corucci, Alessandro A1 - Gligorevic, Snjezana A1 - Monorchio, Agostino T1 - Estimation of airport surface propagation channel: ray tracing model and measurements T2 - Proceedings of the 5th European Conference on Antennas and Propagation (EUCAP) : 11 - 15 April 2011, Rome, Italy Y1 - 2011 SN - 978-1-4577-0250-1 SP - 1634 EP - 1638 ER - TY - JOUR A1 - Umutlu, Lale A1 - Orzada, Stephan A1 - Kinner, Sonja A1 - Maderwald, Stefan A1 - Bronte, Irina A1 - Bitz, Andreas A1 - Kraff, Oliver A1 - Ladd, Susanne C. A1 - Antoch, Gerald A1 - Ladd, Mark E. A1 - Quick, Harald H. A1 - Lauenstein, Thomas C. T1 - Renal imaging at 7 Tesla: preliminary results JF - European Radiology N2 - Objective To investigate the feasibility of 7T MR imaging of the kidneys utilising a custom-built 8-channel transmit/receive radiofrequency body coil. Methods In vivo unenhanced MR was performed in 8 healthy volunteers on a 7T whole-body MR system. After B0 shimming the following sequences were obtained: 1) 2D and 3D spoiled gradient-echo sequences (FLASH, VIBE), 2) T1-weighted 2D in and opposed phase 3) True-FISP imaging and 4) a T2-weighted turbo spin echo (TSE) sequence. Visual evaluation of the overall image quality was performed by two radiologists. Results Renal MRI at 7T was feasible in all eight subjects. Best image quality was found using T1-weighted gradient echo MRI, providing high anatomical details and excellent conspicuity of the non-enhanced vasculature. With successful shimming, B1 signal voids could be effectively reduced and/or shifted out of the region of interest in most sequence types. However, T2-weighted TSE imaging remained challenging and strongly impaired because of signal heterogeneities in three volunteers. Conclusion The results demonstrate the feasibility and diagnostic potential of dedicated 7T renal imaging. Further optimisation of imaging sequences and dedicated RF coil concepts are expected to improve the acquisition quality and ultimately provide high clinical diagnostic value. Y1 - 2011 SN - 1432-1084 VL - 21 IS - 4 SP - 841 EP - 849 PB - Springer CY - Berlin ER - TY - JOUR A1 - Schubert, Nicole A1 - Scholl, Ingrid T1 - Comparing GPU-based multi-volume ray casting techniques JF - Computer Science - Research and Development Y1 - 2011 SN - 1865-2042 VL - 26 IS - 12 SP - 39 EP - 50 PB - Springer CY - Berlin ER - TY - JOUR A1 - Scholl, Ingrid A1 - Aach, Til A1 - Deserno, Thomas M. A1 - Kuhlen, Torsten T1 - Challenges of medical image processing JF - Computer Science - Research and Development Y1 - 2011 SN - 1865-2042 VL - 26 IS - 1-2 SP - 5 EP - 13 PB - Springer CY - Berlin ER - TY - CHAP A1 - Schneckenburger, N. A1 - Franzen, N. A1 - Gligorevic, Snjezana A1 - Schnell, M. T1 - L-band compatibility of LDACS1 T2 - IEEE/AIAA 30th Digital Avionics Systems Conference (DASC) : 16 - 20 Oct. 2011, Seattle, Wash. Y1 - 2011 SN - 978-1-61284-797-9 SN - 2155-7195 SP - 4C3-1 EP - 4C3-11 ER - TY - JOUR A1 - Schiffer, Stefan A1 - Ferrein, Alexander A1 - Lakemeyer, Gerhard T1 - Reasoning with Qualitative Positional Information for Domestic Domains in the Situation Calculus JF - Journal of Intelligent & Robotic Systems Y1 - 2011 SN - 0921-0296 VL - 63 IS - 2 SP - 273 EP - 300 PB - Springer CY - Berlin ER - TY - CHAP A1 - Schiffer, Stefan A1 - Ferrein, Alexander A1 - Lakemeyer, Gerhard T1 - Fuzzy representations and control for domestic service robots in Golog T2 - Intelligent robotics and applications : 4th International conference, ICIRA 2011, Aachen, Germany, December 6-8, 2011, proceedings, part I. (Lecture notes in computer science ; 7102) Y1 - 2011 SN - 978-3-642-25486-4 SP - 241 EP - 250 ER - TY - JOUR A1 - Schaefer, Thomas A1 - Höfken, Hans-Wilhelm A1 - Schuba, Marko T1 - Windows Phone 7 from a Digital Forensics’ Perspective Y1 - 2011 N1 - ICDF2C <3, 2011, Dublin> PB - Springer CY - Berlin ER - TY - JOUR A1 - Prochnow, Nora A1 - Gebing, Tina A1 - Ladage, Kerstin A1 - Krause-Finkeldey, Dorothee A1 - Ourdi, Abessamad El A1 - Bitz, Andreas A1 - Streckert, Joachim A1 - Hansen, Volkert A1 - Dermietzel, Rolf T1 - Electromagnetic field effect or simply stress? Effects of UMTS exposure on hippocampal longterm plasticity in the context of procedure related hormone release JF - PLoS one N2 - Harmful effects of electromagnetic fields (EMF) on cognitive and behavioural features of humans and rodents have been controversially discussed and raised persistent concern about adverse effects of EMF on general brain functions. In the present study we applied radio-frequency (RF) signals of the Universal Mobile Telecommunications System (UMTS) to full brain exposed male Wistar rats in order to elaborate putative influences on stress hormone release (corticosteron; CORT and adrenocorticotropic hormone; ACTH) and on hippocampal derived synaptic long-term plasticity (LTP) and depression (LTD) as electrophysiological hallmarks for memory storage and memory consolidation. Exposure was computer controlled providing blind conditions. Nominal brain-averaged specific absorption rates (SAR) as a measure of applied mass-related dissipated RF power were 0, 2, and 10 W/kg over a period of 120 min. Comparison of cage exposed animals revealed, regardless of EMF exposure, significantly increased CORT and ACTH levels which corresponded with generally decreased field potential slopes and amplitudes in hippocampal LTP and LTD. Animals following SAR exposure of 2 W/kg (averaged over the whole brain of 2.3 g tissue mass) did not differ from the sham-exposed group in LTP and LTD experiments. In contrast, a significant reduction in LTP and LTD was observed at the high power rate of SAR (10 W/kg). The results demonstrate that a rate of 2 W/kg displays no adverse impact on LTP and LTD, while 10 W/kg leads to significant effects on the electrophysiological parameters, which can be clearly distinguished from the stress derived background. Our findings suggest that UMTS exposure with SAR in the range of 2 W/kg is not harmful to critical markers for memory storage and memory consolidation, however, an influence of UMTS at high energy absorption rates (10 W/kg) cannot be excluded. Y1 - 2011 U6 - http://dx.doi.org/10.1371/journal.pone.0019437 VL - 6 IS - 5 PB - PLOS CY - San Francisco ER - TY - JOUR A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Schäfer, Lena C. A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Maderwald, Stefan T1 - Open design eight-channel transmit/receive coil for high-resolution and real-time ankle imaging at 7 T JF - Medical Physics N2 - Purpose: At 1.5 T, real-time MRI of joint movement has been shown to be feasible. However, 7 T, provides higher SNR and thus an improved potential for parallel imaging acceleration. The purpose of this work was to build an open, U-shaped eight-channel transmit/receive microstrip coil for 7 T MRI to enable high-resolution and real-time imaging of the moving ankle joint. Methods: A U-shaped eight-channel transmit/receive array for the human ankle was built.urn:x-wiley:00942405:mp3399:equation:mp3399-math-0001-parameters and urn:x-wiley:00942405:mp3399:equation:mp3399-math-0002-factor were measured. SAR calculations of different ankle postures were performed to ensure patient safety. Inhomogeneities in the transmit field consequent to the open design were compensated for by the use of static RF shimming. High-resolution and real-time imaging was performed in human volunteers. Results: The presented array showed good performance with regard to patient comfort and image quality. High acceleration factors of up to 4 are feasible without visible acceleration artifacts. Reasonable image homogeneity was achieved with RF shimming. Conclusions: Open, noncylindrical designs for transmit/receive coils are practical at 7 T and real-time imaging of the moving joint is feasible with the presented coil design. Y1 - 2011 U6 - http://dx.doi.org/10.1118/1.3553399 SN - 2473-4209 VL - 38 IS - 3 SP - 1162 EP - 1167 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Niemüller, Tim A1 - Ferrein, Alexander A1 - Eckel, Gerhard A1 - Pirro, David A1 - Podbregar, Patrick A1 - Kellner, Tobias A1 - Rath, Christoph A1 - Steinbauer, Gerald T1 - Providing Ground-truth Data for the Nao Robot Platform JF - RoboCup 2010: Robot Soccer World Cup XIV Y1 - 2011 SN - 978-3-642-20217-9 N1 - Lecture Notes in Computer Science ; 6556 SP - 133 EP - 144 PB - Springer CY - Berlin ER - TY - JOUR A1 - Mayer, Claudia T1 - Das globale Dorf ist sein bekanntes Schlagwort JF - Aachener Nachrichten KW - McLuhan, Marshall Y1 - 2011 N1 - zugleich Aachener Zeitung vom 27.12.2011 Seite 12 IS - 27.12.2011 SP - 12 EP - 12 ER - TY - JOUR A1 - Maus, Stefan A1 - Höfken, Hans-Wilhelm A1 - Schuba, Marko T1 - Forensic Analysis of Geodata in Android Smartphones Y1 - 2011 N1 - Cyberforensics 2011, Glasgow SP - 1 EP - 11 ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Breyer, Tobias A1 - Kruszona, Stefan A1 - Maderwald, Stefan A1 - Brote, Irina A1 - Gizewski, Elke R. A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - A transmit/receive radiofrequency array for imaging the carotid arteries at 7 Tesla: coil design and first in vivo results JF - Investigative Radiology N2 - Objective: To develop a transmit/receive radiofrequency (RF) array for magnetic resonance imaging (MRI) of the carotid arteries at 7 T. The prototype is characterized in numerical simulations and bench measurements, and the feasibility of plaque imaging at 7 T is demonstrated in first in vivo images. Materials and Methods: The RF phased array coil consists of 8 surface loop coils. To allow imaging of both sides of the neck, the RF array is divided into 2 coil clusters, each with 4 overlapping loop elements. For safety validation, numerical computations of the RF field distribution and the corresponding specific absorption rate were performed on the basis of a heterogeneous human body model. To validate the coil model, maps of the transmit B1+ field were compared between simulation and measurement. In vivo images of a healthy volunteer and a patient (ulcerating plaque and a 50% stenosis of the right internal carotid artery) were acquired using a 3-dimensional FLASH sequence with a high isotropic spatial resolution of 0.54 mm as well as using pulse-triggered proton density (PD)/T2-weighted turbo spin echo sequences. Results: Measurements of the S-parameters yielded a reflection and isolation of the coil elements of better than −18 and −13 dB, respectively. Measurements of the g-factor indicated good image quality for parallel imaging acceleration factors up to 2.4. A similar distribution and a very good match of the absolute values were found between the measured and simulated B1+ transmit RF field for the validation of the coil model. In vivo images revealed good signal excitation of both sides of the neck and a high vessel-to-background image contrast for the noncontrast-enhanced 3-dimensional FLASH sequence. Imaging at 7 T could depict the extent of stenosis, and revealed the disruption and ulcer of the plaque. Conclusions: This study demonstrates that 2 four-channel transmit/receive RF arrays for each side of the neck is a suitable concept for in vivo MRI of the carotid arteries at 7 Tesla. Further studies are needed to explore and exploit the full potential of 7 T high-field MRI for carotid atherosclerotic plaque imaging. Y1 - 2011 U6 - http://dx.doi.org/10.1097/RLI.0b013e318206cee4 SN - 1536-0210 VL - 46 IS - 4 SP - 246 EP - 254 PB - Wolters Kluwer CY - Köln ER - TY - JOUR A1 - Hüning, Felix T1 - PowerMOSFETs in ANL2-Technologie : Ansteuerungen bis in den kW-Bereich mit wenig Verlustleistung und Platzbedarf JF - Elektronik-Industrie Y1 - 2011 SN - 0174-5522 VL - 42 IS - 10 SP - 36 EP - 39 PB - Hüthig CY - Heidelberg ER - TY - JOUR A1 - Hartung, Frank A1 - Kesici, Sinan A1 - Catrein, Daniel T1 - DRM protected Dynamic Adaptive HTTP Streaming JF - Proceedings of the 2011 ACM Multimedia Systems Conference [Elektronische Ressource] : February 23 - 25, 2011, San Jose, CA, USA / sponsored by: ACM SIGMM Y1 - 2011 SN - 9781450305181 N1 - ACM Multimedia Systems Conference ; (2 : ; 2011.02.23-25 : ; San Jose, Calif.) SP - 277 EP - 282 PB - ACM CY - New York, NY ER - TY - JOUR A1 - Hamm, Laurits A1 - Hartung, Frank T1 - High Quality Visual Communication based on IMS JF - Mobilkommunikation : Technologien und Anwendungen ; Vorträge der 16. ITG-Fachtagung vom 18. bis 19. Mai 2011 in Osnabrück / Veranst.: Informationstechnische Gesellschaft im VDE (ITG) ... Tagungsleitung: Ralf Tönjes. Programmkomitee/Hrsg.: Peter Roer Y1 - 2011 SN - 978-3-8007-3352-1 N1 - ITG-Fachbericht ; 230 ; Fachtagung Mobilkommunikation <16, 2011, Osnabrück> SP - 80 EP - 85 PB - VDE-Verl. CY - Berlin ER - TY - JOUR A1 - Gspandl, Stephan A1 - Pill, Ingo A1 - Reip, Michael A1 - Steinbauer, Gerald A1 - Ferrein, Alexander T1 - Belief Management for High-Level Robot Programs JF - Proceedings of the Twenty-Second International Joint Conference on Artificial Intelligence [electronic resource] : Barcelona, Catalonia, Spain, 16 - 22 July 2011 / sponsored by International Joint Conferences on Artificial Intelligence (IJCAI) and the Association for the Advancement of Artificial Intelligence (AAAI). Ed. by Toby Walsh Y1 - 2011 N1 - International Joint Conference on Artificial Intelligence ; (22 : ; 2011.07.16-22 : ; Barcelona, Spain) ; IJCAI ; (22 : ; 2011.07.16-22 : ; Barcelona, Spain) SP - 900 EP - 905 ER - TY - CHAP A1 - Gligorevic, Snjezana A1 - Schneckenburger, N. A1 - Franzen, N. A1 - Schnell, Michael A1 - Müller, S. A1 - Günzel, H. T1 - L-Band compatibility of LDACS1 T2 - 3rd CEAS Air and Space Conference, 24 - 28 October 2011, Venezia, Italy Y1 - 2011 SP - 1 EP - 8 ER - TY - CHAP A1 - Gligorevic, Snjezana A1 - Epple, Ulrich A1 - Schnell, Michael T1 - The LDACS1 physical layer design T2 - Future aeronautical communications Y1 - 2011 SN - 978-953-307-625-6 SP - 317 EP - 332 PB - Intech CY - London ER -