TY - JOUR A1 - Bassam, Rasha A1 - Artmann, Gerhard A1 - Hescheler, Jürgen A1 - Graef, T. A1 - Temiz Artmann, Aysegül A1 - Porst, Dariusz A1 - Linder, Peter A1 - Kayser, Peter A1 - Arinkin, Vladimir A1 - Gossmann, Matthias A1 - Digel, Ilya T1 - Alterations in human hemoglobin structure related to red blood cell storage N2 - The importance of the availability of stored blood or blood cells, respectively, for urgent transfusion cannot be overestimated. Nowadays, blood storage becomes even more important since blood products are used for epidemiological studies, bio-technical research or banked for transfusion purposes. Thus blood samples must not only be processed, stored, and shipped to preserve their efficacy and safety, but also all parameters of storage must be recorded and reported for Quality Assurance. Therefore, blood banks and clinical research facilities are seeking more accurate, automated means for blood storage and blood processing. KW - Hämoglobin KW - Hämoglobinstruktur KW - Blutzellenlagerung KW - Hemoglobin structure KW - Red blood cell storage Y1 - 2011 ER - TY - JOUR A1 - Uysal, Karya A1 - Creutz, Till A1 - Firat, Ipek Seda A1 - Artmann, Gerhard A1 - Teusch, Nicole A1 - Temiz Artmann, Aysegül T1 - Bio-functionalized ultra-thin, large-area and waterproof silicone membranes for biomechanical cellular loading and compliance experiments JF - Polymers N2 - Biocompatibility, flexibility and durability make polydimethylsiloxane (PDMS) membranes top candidates in biomedical applications. CellDrum technology uses large area, <10 µm thin membranes as mechanical stress sensors of thin cell layers. For this to be successful, the properties (thickness, temperature, dust, wrinkles, etc.) must be precisely controlled. The following parameters of membrane fabrication by means of the Floating-on-Water (FoW) method were investigated: (1) PDMS volume, (2) ambient temperature, (3) membrane deflection and (4) membrane mechanical compliance. Significant differences were found between all PDMS volumes and thicknesses tested (p < 0.01). They also differed from the calculated values. At room temperatures between 22 and 26 °C, significant differences in average thickness values were found, as well as a continuous decrease in thicknesses within a 4 °C temperature elevation. No correlation was found between the membrane thickness groups (between 3–4 µm) in terms of deflection and compliance. We successfully present a fabrication method for thin bio-functionalized membranes in conjunction with a four-step quality management system. The results highlight the importance of tight regulation of production parameters through quality control. The use of membranes described here could also become the basis for material testing on thin, viscous layers such as polymers, dyes and adhesives, which goes far beyond biological applications. Y1 - 2022 SN - 2073-4360 VL - 14 IS - 11 SP - 2213 PB - MDPI CY - Basel ER - TY - JOUR A1 - Maggakis-Kelemen, C. A1 - Bork, M. A1 - Kayser, Peter A1 - Biselli, Manfred A1 - Artmann, Gerhard T1 - Biological and mechanical quality of red blood cells cultured from human umbilical cord blood stem cells JF - Medical and biological engineering and computing. 41 (2003), H. 3 Y1 - 2003 SN - 0140-0118 SP - 350 EP - 356 ER - TY - JOUR A1 - Bork, M. A1 - Kelemen, C. A1 - Biselli, Manfred A1 - Artmann, Gerhard T1 - Biophysikalische Charakterisierung ex vivo kultivierter menschlicher Erythrozythen JF - Biomedizinische Technik = Biomedical Engineering. 45 (2000), H. s1 Y1 - 2000 SN - 1862-278X SP - 471 EP - 472 ER - TY - JOUR A1 - Artmann, Gerhard T1 - Cellular engineering - a challenge for engineers? / Artmann, G. M. JF - Biomedizinische Technik = Biomedical Engineering. 45 (2000), H. s1 Y1 - 2000 SN - 1862-278X SP - 449 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Kelemen, C. A1 - Porst, Dariusz A1 - Büldt, G. T1 - Cellular engineering: Crash tests an menschlichen Erythrozyten geben Aufschluß über versteckte Materialeigenschaften zellulärer Proteine / Artmann, G. M. ; Kelemen, Ch. ; Porst, D. ; Büldt, G. ; Chien, Shu JF - Biomedizinische Technik / Biomedical Engineering. 43 (1998), H. s1 Y1 - 1998 SN - 1862-278 SP - 446 EP - 447 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Hueck, I. S. A1 - Hollweg, H. G. A1 - Schmid-Schönbein, G. W. T1 - Chlorpromazine modulates the Morphological Macro- and Microstructure of Endothelial Cells. Hueck, I. S.; Hollweg, H. G.; Schmid-Schönbein, G. W.; Artmann, Gerhard Michael JF - American Journal of Physiology. Cell Physiology. 278 (2000), H. 5 Y1 - 2000 SN - 1522-1563 N1 - Zählung: C873- C878 SP - 873 EP - 878 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Burns, Laura A1 - Canaves, Jaume M. A1 - Temiz Artmann, Aysegül T1 - Circular dichroism spectra of human hemoglobin reveal a reversible structural transition at body temperature JF - European Biophysics Journal. 33 (2004), H. 6 Y1 - 2004 SN - 1432-1017 SP - 490 EP - 496 ER - TY - JOUR A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül A1 - Nishikawa, K. A1 - Artmann, Gerhard T1 - Cluster air-ion effects on bacteria and moulds JF - Biomedizinische Technik. 49 (2004), H. Erg.-Bd. 2 Y1 - 2004 SN - 0932-4666 SP - 1040 EP - 1041 ER - TY - JOUR A1 - Kurz, R. A1 - Linder, Peter A1 - Trzewik, Jürgen A1 - Rüffer, M. A1 - Artmann, Gerhard A1 - Digel, Ilya A1 - Rothermel, A. A1 - Robitzki, A. A1 - Temiz Artmann, Aysegül T1 - Contractile tension and beating rates of self-exciting monolayers and 3D-tissue constructs of neonatal rat cardiomyocytes JF - Medical and Biological Engineering and Computing N2 - The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocytes. Cells were grown either within flexible, circular collagen gels or as monolayer on top of respective 1-mum thin silicone membranes. Membrane and cells were bulged outwards by air pressure. This biaxial strain distribution is rather similar the beating, blood-filled heart. The setup allowed presetting the mechanical residual stress level externally by adjusting the centre deflection, thus, mimicking hypertension in vitro. Tension was measured as oscillating differential pressure change between chamber and environment. A 0.5-mm thick collagen-cardiac myocyte tissue construct induced after 2 days of culturing (initial cell density 2 x 10(4) cells/ml), a mechanical tension of 1.62 +/- 0.17 microN/mm(2). Mechanical load is an important growth regulator in the developing heart, and the orientation and alignment of cardiomyocytes is stress sensitive. Therefore, it was necessary to develop the CellDrum technology with its biaxial stress-strain distribution and defined mechanical boundary conditions. Cells were exposed to strain in two directions, radially and circumferentially, which is similar to biaxial loading in real heart tissues. Thus, from a biomechanical point of view, the system is preferable to previous setups based on uniaxial stretching. Y1 - 2010 U6 - http://dx.doi.org/10.1007/s11517-009-0552-y SN - 1741-0444 VL - 48 IS - 1 SP - 59 EP - 65 PB - Springer Nature CY - Cham ER - TY - JOUR A1 - Kurulgan Demirci, Eylem A1 - Linder, Peter A1 - Demirci, Taylan A1 - Trzewik, Jürgen A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - Contractile tension of endothelial cells: An LPS based in-vitro sepsis model JF - IUBMB Life. 61 (2009), H. 3 Y1 - 2009 SN - 1521-6543 N1 - Abstracts: Turkish Society of Molecular Medicine, Third International Congress of Molecular Medicine, May 5-8, 2009, Istanbul, Turkey SP - 307 EP - 308 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Stadler, Andreas M. A1 - Embs, Jan P. A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Unruh, Tobias A1 - Büldt, Georg A1 - Zaccai, Guiseppe T1 - Cytoplasmic water and hydration layer dynamics in human red blood cells JF - Journal of the American Chemical Society. 50 (2008), H. 130 Y1 - 2008 SN - 1520-5126 SP - 16852 EP - 16853 ER - TY - JOUR A1 - Maggakis-Kelemen, Christina A1 - Biselli, Manfred A1 - Artmann, Gerhard T1 - Determination of the elastic shear modulus of cultured human red blood cells JF - Biomedizinische Technik. 47 (2002), H. Suppl. 1 Pt. 1 Y1 - 2002 SN - 0013-5585 N1 - Druckausgabe unter 63 Z 471 vorhanden SP - 106 EP - 109 ER - TY - JOUR A1 - Seifarth, Volker A1 - Goßmann, Matthias A1 - Grosse, J. O. A1 - Becker, C. A1 - Heschel, I. A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - Development of a Bioreactor to Culture Tissue Engineered Ureters Based on the Application of Tubular OPTIMAIX 3D Scaffolds JF - Urologia Internationalis Y1 - 2015 U6 - http://dx.doi.org/10.1159/000368419 SN - 0042-1138 VL - 2015 IS - 95 SP - 106 EP - 113 PB - Karger CY - Basel ER - TY - JOUR A1 - Artmann, Gerhard A1 - Montanus, M. A1 - Teitel, P. T1 - Die photometrische Kapillaraggregation- ein neues Verfahren zur Messung der Erythrozytenaggregation. Montanus, M.; Artmann, Gerhard Michael; Teitel, P. JF - Biomedizinische Technik = Biomedical engineering. 36 (1991) Y1 - 1991 SN - 0013-5585 SP - 213 EP - 215 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Li, Anlan T1 - Dihydroergocryptine maintains erythrocyte fluidity in acidotic and hyperosmolar suspensions modelling hypoxic and ischemic microcirculation. Li, Anlan; Artmann, Gerhard Michael JF - Clinical Hemorheology. 15 (1994), H. 2 Y1 - 1994 SN - 0271-5198 SP - 133 EP - 146 ER - TY - JOUR A1 - Zerlin, Kay A1 - Digel, Ilya A1 - Stadler, Andreas M. A1 - Büldt, Georg A1 - Zaccai, Guiseppe A1 - Artmann, Gerhard T1 - Dynamics and interactions of hemoglobin in human red blood cells and concentrated hemoglobin solutions JF - Regenerative medicine. 2 (2007), H. 5 Y1 - 2007 SN - 1746-0751 N1 - Proceedings of the 3rd World Congress on Regenerative Medicine. October 18-20, 2007. Leipzig, Germany SP - 573 EP - 573 ER - TY - JOUR A1 - Stadler, Andreas M. A1 - Zerlin, Kay A1 - Digel, Ilya A1 - Büldt, Georg A1 - Zaccai, Guiseppe A1 - Artmann, Gerhard T1 - Dynamics and interactions of hemoglobin in red blood cells JF - Tissue Engineering Part A. 14 (2008), H. 5 Y1 - 2008 SN - 1937-3341 N1 - TERMIS EU 2008 Porto Meeting June 22–26, 2008 Porto Congress Center–Alfândega Portugal SP - 724 EP - 724 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Li, Anlan A1 - Seipelt, H. A1 - Müller, C. [u.a.] T1 - Effects of salicylic acid derivatives on red blood cell membranes. Li, Anlan; Seipelt, H.; Müller, C.;Shi, Yong de; Artmann, Gerhard Michael JF - Pharmacology and Toxicology. 85 (1999) Y1 - 1999 SN - 0902-9938 SP - 206 EP - 211 ER - TY - JOUR A1 - Bassam, Rasha A1 - Digel, Ilya A1 - Hescheler, Jürgen A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard T1 - Effects of spermine NONOate and ATP on protein aggregation: light scattering evidences JF - BMC Biophysics Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?10.1186/2046-1682-6-1 SN - 2046-1682 SP - 1 EP - 14 PB - BioMed Central CY - London ER -