TY - JOUR A1 - Lindner, Simon A1 - Burger, René A1 - Rutledge, Douglas N. A1 - Do, Xuan Tung A1 - Rumpf, Jessica A1 - Diehl, Bernd W. K. A1 - Schulze, Margit A1 - Monakhova, Yulia T1 - Is the calibration transfer of multivariate calibration models between high- and low-field NMR instruments possible? A case study of lignin molecular weight JF - Analytical chemistry N2 - Although several successful applications of benchtop nuclear magnetic resonance (NMR) spectroscopy in quantitative mixture analysis exist, the possibility of calibration transfer remains mostly unexplored, especially between high- and low-field NMR. This study investigates for the first time the calibration transfer of partial least squares regressions [weight average molecular weight (Mw) of lignin] between high-field (600 MHz) NMR and benchtop NMR devices (43 and 60 MHz). For the transfer, piecewise direct standardization, calibration transfer based on canonical correlation analysis, and transfer via the extreme learning machine auto-encoder method are employed. Despite the immense resolution difference between high-field and low-field NMR instruments, the results demonstrate that the calibration transfer from high- to low-field is feasible in the case of a physical property, namely, the molecular weight, achieving validation errors close to the original calibration (down to only 1.2 times higher root mean square errors). These results introduce new perspectives for applications of benchtop NMR, in which existing calibrations from expensive high-field instruments can be transferred to cheaper benchtop instruments to economize. Y1 - 2022 SN - 1520-6882 U6 - http://dx.doi.org/10.1021/acs.analchem.1c05125 VL - 94 IS - 9 SP - 3997 EP - 4004 PB - ACS Publications CY - Washington, DC ER - TY - JOUR A1 - Maurischat, Andreas T1 - Algebraic independence of the Carlitz period and its hyperderivatives JF - Journal of Number Theory KW - Drinfeld modules KW - Periods KW - t-modules KW - Transcendence KW - Higher derivations Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.jnt.2022.01.006 SN - 0022-314X VL - 240 SP - 145 EP - 162 PB - Elsevier CY - Orlando, Fla. ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Ortner, Marion A1 - Conradi, Anna A1 - Hacker, Patricia A1 - Hauser, Christine A1 - Günthner, Roman A1 - Moser, Michaela A1 - Muggenthaler, Claudia A1 - Diehl-Schmid, Janine A1 - Priller, Josef A1 - Schmaderer, Christoph A1 - Grimmer, Timo T1 - Altered retinal cerebral vessel oscillation frequencies in Alzheimer's disease compatible with impaired amyloid clearance JF - Neurobiology of Aging N2 - Retinal vessels are similar to cerebral vessels in their structure and function. Moderately low oscillation frequencies of around 0.1 Hz have been reported as the driving force for paravascular drainage in gray matter in mice and are known as the frequencies of lymphatic vessels in humans. We aimed to elucidate whether retinal vessel oscillations are altered in Alzheimer's disease (AD) at the stage of dementia or mild cognitive impairment (MCI). Seventeen patients with mild-to-moderate dementia due to AD (ADD); 23 patients with MCI due to AD, and 18 cognitively healthy controls (HC) were examined using Dynamic Retinal Vessel Analyzer. Oscillatory temporal changes of retinal vessel diameters were evaluated using mathematical signal analysis. Especially at moderately low frequencies around 0.1 Hz, arterial oscillations in ADD and MCI significantly prevailed over HC oscillations and correlated with disease severity. The pronounced retinal arterial vasomotion at moderately low frequencies in the ADD and MCI groups would be compatible with the view of a compensatory upregulation of paravascular drainage in AD and strengthen the amyloid clearance hypothesis. KW - Alzheimer's disease KW - Retinal vessel analysis KW - Vasomotions KW - Pulsations KW - Mild cognitive impairment Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.neurobiolaging.2022.08.012 SN - 0197-4580 VL - 120 SP - 117 EP - 127 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Colombo, Daniele A1 - Drira, Slah A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - An element-based formulation for ES-FEM and FS-FEM models for implementation in standard solid mechanics finite element codes for 2D and 3D static analysis JF - International Journal for Numerical Methods in Engineering N2 - Edge-based and face-based smoothed finite element methods (ES-FEM and FS-FEM, respectively) are modified versions of the finite element method allowing to achieve more accurate results and to reduce sensitivity to mesh distortion, at least for linear elements. These properties make the two methods very attractive. However, their implementation in a standard finite element code is nontrivial because it requires heavy and extensive modifications to the code architecture. In this article, we present an element-based formulation of ES-FEM and FS-FEM methods allowing to implement the two methods in a standard finite element code with no modifications to its architecture. Moreover, the element-based formulation permits to easily manage any type of element, especially in 3D models where, to the best of the authors' knowledge, only tetrahedral elements are used in FS-FEM applications found in the literature. Shape functions for non-simplex 3D elements are proposed in order to apply FS-FEM to any standard finite element. KW - distorted element KW - ES-FEM KW - FS-FEM KW - non-simplex S-FEM elements KW - S-FEM Y1 - 2022 U6 - http://dx.doi.org/10.1002/nme.7126 SN - 1097-0207 VL - 124 IS - 2 SP - 402 EP - 433 PB - Wiley CY - Chichester ER - TY - JOUR A1 - Bhattarai, Aroj A1 - May, Charlotte Anabell A1 - Staat, Manfred A1 - Kowalczyk, Wojciech A1 - Tran, Thanh Ngoc T1 - Layer-specific damage modeling of porcine large intestine under biaxial tension JF - Bioengineering N2 - The mechanical behavior of the large intestine beyond the ultimate stress has never been investigated. Stretching beyond the ultimate stress may drastically impair the tissue microstructure, which consequently weakens its healthy state functions of absorption, temporary storage, and transportation for defecation. Due to closely similar microstructure and function with humans, biaxial tensile experiments on the porcine large intestine have been performed in this study. In this paper, we report hyperelastic characterization of the large intestine based on experiments in 102 specimens. We also report the theoretical analysis of the experimental results, including an exponential damage evolution function. The fracture energies and the threshold stresses are set as damage material parameters for the longitudinal muscular, the circumferential muscular and the submucosal collagenous layers. A biaxial tensile simulation of a linear brick element has been performed to validate the applicability of the estimated material parameters. The model successfully simulates the biomechanical response of the large intestine under physiological and non-physiological loads. KW - biaxial tensile experiment KW - anisotropy KW - hyperelastic KW - constitutive modeling KW - damage Y1 - 2022 U6 - http://dx.doi.org/10.3390/bioengineering9100528 SN - 2306-5354 N1 - Der Artikel gehört zum Sonderheft "Computational Biomechanics" VL - 9 IS - 10, Early Access SP - 1 EP - 17 PB - MDPI CY - Basel ER - TY - JOUR A1 - Philipp, Mohr A1 - Efthimiou, Nikos A1 - Pagano, Fiammetta A1 - Kratochwil, Nicolaus A1 - Pizzichemi, Marco A1 - Tsoumpas, Charalampos A1 - Auffray, Etiennette A1 - Ziemons, Karl T1 - Image reconstruction analysis for positron emission tomography with heterostructured scintillators JF - IEEE Transactions on Radiation and Plasma Medical Sciences N2 - The concept of structure engineering has been proposed for exploring the next generation of radiation detectors with improved performance. A TOF-PET geometry with heterostructured scintillators with a pixel size of 3.0×3.1×15 mm3 was simulated using Monte Carlo. The heterostructures consisted of alternating layers of BGO as a dense material with high stopping power and plastic (EJ232) as a fast light emitter. The detector time resolution was calculated as a function of the deposited and shared energy in both materials on an event-by-event basis. While sensitivity was reduced to 32% for 100 μm thick plastic layers and 52% for 50 μm, the CTR distribution improved to 204±49 ps and 220±41 ps respectively, compared to 276 ps that we considered for bulk BGO. The complex distribution of timing resolutions was accounted for in the reconstruction. We divided the events into three groups based on their CTR and modeled them with different Gaussian TOF kernels. On a NEMA IQ phantom, the heterostructures had better contrast recovery in early iterations. On the other hand, BGO achieved a better contrast to noise ratio (CNR) after the 15th iteration due to the higher sensitivity. The developed simulation and reconstruction methods constitute new tools for evaluating different detector designs with complex time responses. KW - TOF PET KW - Heterostructure KW - Metascintillator KW - Multiple TOF kernels KW - Image Reconstruction Y1 - 2022 U6 - http://dx.doi.org/10.1109/TRPMS.2022.3208615 SN - 2469-7311 SN - 2469-7303 VL - 7 IS - 1 SP - 41 EP - 51 PB - IEEE CY - New York, NY ER - TY - JOUR A1 - Engelmann, Ulrich M. A1 - Pourshahidi, Mohammad Ali A1 - Shalaby, Ahmed A1 - Krause, Hans-Joachim T1 - Probing particle size dependency of frequency mixing magnetic detection with dynamic relaxation simulation JF - Journal of Magnetism and Magnetic Materials N2 - Biomedical applications of magnetic nanoparticles (MNP) fundamentally rely on the particles’ magnetic relaxation as a response to an alternating magnetic field. The magnetic relaxation complexly depends on the interplay of MNP magnetic and physical properties with the applied field parameters. It is commonly accepted that particle core size is a major contributor to signal generation in all the above applications, however, most MNP samples comprise broad distribution spanning nm and more. Therefore, precise knowledge of the exact contribution of individual core sizes to signal generation is desired for optimal MNP design generally for each application. Specifically, we present a magnetic relaxation simulation-driven analysis of experimental frequency mixing magnetic detection (FMMD) for biosensing to quantify the contributions of individual core size fractions towards signal generation. Applying our method to two different experimental MNP systems, we found the most dominant contributions from approx. 20 nm sized particles in the two independent MNP systems. Additional comparison between freely suspended and immobilized MNP also reveals insight in the MNP microstructure, allowing to use FMMD for MNP characterization, as well as to further fine-tune its applicability in biosensing. Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.jmmm.2022.169965 SN - 0304-8853 VL - 563 IS - In progress, Art. No. 169965 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Pourshahidi, Ali Mohammad A1 - Engelmann, Ulrich M. A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim T1 - Resolving ambiguities in core size determination of magnetic nanoparticles from magnetic frequency mixing data JF - Journal of Magnetism and Magnetic Materials N2 - Frequency mixing magnetic detection (FMMD) has been widely utilized as a measurement technique in magnetic immunoassays. It can also be used for the characterization and distinction (also known as “colourization”) of different types of magnetic nanoparticles (MNPs) based on their core sizes. In a previous work, it was shown that the large particles contribute most of the FMMD signal. This leads to ambiguities in core size determination from fitting since the contribution of the small-sized particles is almost undetectable among the strong responses from the large ones. In this work, we report on how this ambiguity can be overcome by modelling the signal intensity using the Langevin model in thermodynamic equilibrium including a lognormal core size distribution fL(dc,d0,σ) fitted to experimentally measured FMMD data of immobilized MNPs. For each given median diameter d0, an ambiguous amount of best-fitting pairs of parameters distribution width σ and number of particles Np with R2 > 0.99 are extracted. By determining the samples’ total iron mass, mFe, with inductively coupled plasma optical emission spectrometry (ICP-OES), we are then able to identify the one specific best-fitting pair (σ, Np) one uniquely. With this additional externally measured parameter, we resolved the ambiguity in core size distribution and determined the parameters (d0, σ, Np) directly from FMMD measurements, allowing precise MNPs sample characterization. Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.jmmm.2022.169969 SN - 0304-8853 VL - 563 IS - In progress, Art. No. 169969 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Steuer-Dankert, Linda A1 - Gilmartin, Shannon K. A1 - Muller, Carol B. A1 - Dungs, Carolin A1 - Sheppard, Sheri A1 - Leicht-Scholten, Carmen T1 - Expanding engineering limits : a concept for socially responsible education of engineers JF - The international journal of engineering education Y1 - 2019 SN - 0949-149X VL - 35 IS - 2 SP - 658 EP - 673 ER - TY - JOUR A1 - Steuer-Dankert, Linda A1 - Sharma, Mamta Rameshwarlal A1 - Bleck, Wolfgang A1 - Leicht-Scholten, Carmen T1 - Diversity and innovation management in large research groups JF - International Journal of Innovation Management N2 - Contemporary research appreciates a diverse workforce as a potential source of innovation. Researchers explore the fine details of why diversity management is central for generating innovations in heterogeneous research groups and how it could be effectively implemented into organizations. Complex research associations that discuss topics with a high impact on society increasingly address the necessity of establishing a diverse workforce to confront the challenges of tomorrow. Characterized by complex management structures as well as hierarchies, research associations have not been a subject of investigation until now. For this reason, the presented research project aims to develop a diversity and innovation management strategy with the ultimate goal of inducing change in the corporate culture. The proposed approach consisted of six phases; the first two phases investigated the status quo of diversity in the existing organizational structures of member institutes and the variety of particular working cultures within the research association. The third and the fourth phases utilized qualitative and quantitative studies. The third phase focused on the connection of management level to diversity and innovation, and the need for diversity and innovation management, and tailor-made methods of implementing them. The first three phases have been accomplished successfully; preliminary results are already available. The fourth phase will mainly focus on exploring the mind-set of the employees. The fifth phase will consolidate the findings in the first four phases into an implementable strategy. The final phase will address the implementation of this strategy into the organization. Phases 4 to 6 have not yet been undertaken KW - diversity management KW - innovation management KW - research association KW - change management KW - engineering Y1 - 2017 SN - 1757-5877 VL - 5 IS - 2 SP - 49 EP - 72 ER - TY - JOUR A1 - Monakhova, Yulia A1 - Diehl, Bernd W.K. T1 - Nuclear magnetic resonance spectroscopy as an elegant tool for a complete quality control of crude heparin material JF - Journal of Pharmaceutical and Biomedical Analysis N2 - Nuclear magnetic resonance (NMR) spectrometric methods for the quantitative analysis of pure heparin in crude heparin is proposed. For quantification, a two-step routine was developed using a USP heparin reference sample for calibration and benzoic acid as an internal standard. The method was successfully validated for its accuracy, reproducibility, and precision. The methodology was used to analyze 20 authentic porcine heparinoid samples having heparin content between 4.25 w/w % and 64.4 w/w %. The characterization of crude heparin products was further extended to a simultaneous analysis of these common ions: sodium, calcium, acetate and chloride. A significant, linear dependence was found between anticoagulant activity and assayed heparin content for thirteen heparinoids samples, for which reference data were available. A Diffused-ordered NMR experiment (DOSY) can be used for qualitative analysis of specific glycosaminoglycans (GAGs) in heparinoid matrices and, potentially, for quantitative prediction of molecular weight of GAGs. NMR spectrometry therefore represents a unique analytical method suitable for the simultaneous quantitative control of organic and inorganic composition of crude heparin samples (especially heparin content) as well as an estimation of other physical and quality parameters (molecular weight, animal origin and activity). KW - NMR spectroscopy KW - Heparin KW - Crude heparin KW - USP KW - Ions Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.jpba.2022.114915 SN - 0731-7085 VL - 219 IS - Article number: 114915 PB - Elsevier CY - New York, NY ER - TY - JOUR A1 - Kurz, Melanie T1 - Was heißt: Verantwortung im Design? Historische Positionen JF - Boxhorn: das Magazin aus dem Fachbereich Gestaltung der FH Aachen Y1 - 2018 IS - 34 SP - 26 EP - 33 CY - Aachen ER - TY - JOUR A1 - Kurz, Melanie T1 - Images of Sweden in Germany: from Sundborn and Bullerby to Ikea JF - nomad: the magazine for new design culture, business affairs and contemporary lifestyle Y1 - 2019 SN - 2513-0714 IS - 8 SP - 136 EP - 147 ER - TY - JOUR A1 - Uysal, Karya A1 - Creutz, Till A1 - Firat, Ipek Seda A1 - Artmann, Gerhard A1 - Teusch, Nicole A1 - Temiz Artmann, Aysegül T1 - Bio-functionalized ultra-thin, large-area and waterproof silicone membranes for biomechanical cellular loading and compliance experiments JF - Polymers N2 - Biocompatibility, flexibility and durability make polydimethylsiloxane (PDMS) membranes top candidates in biomedical applications. CellDrum technology uses large area, <10 µm thin membranes as mechanical stress sensors of thin cell layers. For this to be successful, the properties (thickness, temperature, dust, wrinkles, etc.) must be precisely controlled. The following parameters of membrane fabrication by means of the Floating-on-Water (FoW) method were investigated: (1) PDMS volume, (2) ambient temperature, (3) membrane deflection and (4) membrane mechanical compliance. Significant differences were found between all PDMS volumes and thicknesses tested (p < 0.01). They also differed from the calculated values. At room temperatures between 22 and 26 °C, significant differences in average thickness values were found, as well as a continuous decrease in thicknesses within a 4 °C temperature elevation. No correlation was found between the membrane thickness groups (between 3–4 µm) in terms of deflection and compliance. We successfully present a fabrication method for thin bio-functionalized membranes in conjunction with a four-step quality management system. The results highlight the importance of tight regulation of production parameters through quality control. The use of membranes described here could also become the basis for material testing on thin, viscous layers such as polymers, dyes and adhesives, which goes far beyond biological applications. Y1 - 2022 SN - 2073-4360 VL - 14 IS - 11 SP - 2213 PB - MDPI CY - Basel ER - TY - JOUR A1 - Büdenbender, Martin A1 - Janssen, Matthias A1 - Wobben, Magnus T1 - Versorgungssicherheit auf Elektrizitätsmärkten — Investitionsdilemma durch ineffizientes Marktdesign? JF - Zeitschrift für Energiewirtschaft N2 - Dieser Artikel befasst sich mit dem Investitionsdilemma in der Stromerzeugung, welches in unzureichend ausgestalteten liberalisierten Strommärkten zu einem gesamtwirtschaftlich unerwünscht geringen Niveau an Versorgungssicherheit führt. Die originären Ursachen im deutschen Strommarkt liegen in einer eingeschränkten Schadenersatzpflicht der Lieferanten im Falle eines kapazitätsbedingten Stromausfalls und in der zeitlichen Differenz zwischen letzter Handelsmöglichkeit und Lieferung. Letzteres verhindert ein jederzeitiges individuelles Glattstellen von unerwartet auftretenden Ein- bzw. Ausspeiseänderungen. Des Weiteren führen Faktoren wie die fehlende Partizipation der Endverbraucher am Großhandelsmarkt, die nur undifferenziert mögliche Abschaltung von Endverbrauchern oder time lags durch lange Bau- und Genehmigungszeiten von Erzeugungskapazitäten in Verbindung mit über lange Zeiträume nicht versicherbaren Risiken bezüglich Brennstoff-, CO2-Zertifikate- und Strompreisen zu einer Verschärfung der Problematik. Sinnvolle Lösungsansätze sind zum einen die Erhöhung der Intraday-Handelsliquidität zur Verbesserung der Markträumungsfunktion bis möglichst kurz vor Stromlieferung, was z. B. durch eine Förderung der Direktvermarktung Erneuerbarer Energien erreicht werden kann. Zum anderen trägt ein verstärkter Ausbau von smart metern bei Endverbrauchern zu einer höheren Versorgungssicherheit bei, da dies die Glättung von Lastspitzen und die Artikulation der tatsächlichen Zahlungsbereitschaft von Endverbrauchern am Großhandelsmarkt ermöglicht. Y1 - 2009 SN - 1866-2765 VL - 33 IS - 1 SP - 49 EP - 61 ER - TY - JOUR A1 - Büdenbender, Martin T1 - Der Atomausstieg in Deutschland – ein zukunftsfähiger Sonderweg im europäischen Kontext? JF - atw International Journal for Nuclear Power T2 - Opting out of the Peaceful Use of Nuclear Power in Germany — A Promising Special Approach in the European Context KW - Kernenergie KW - Atomausstieg KW - Europäische Energiepolitik Y1 - 2009 SN - 14315254 VL - 54 IS - 10 SP - 616 EP - 627 PB - Inforum CY - Berlin ER - TY - JOUR A1 - Büdenbender, Martin T1 - Auswirkungen der europäischen Energiepolitik auf den deutschen Atomausstieg JF - Zeitschrift für Energiewirtschaft N2 - Nach der Bundestagswahl am 27. September 2009 steht der Atomausstieg in Deutschland wieder ganz oben auf der politischen Agenda. Eine aktuelle Bestandsaufnahme aller ma\geblichen Argumente erscheint somit zwingend notwendig. Dabei sollte der Blickwinkel nicht national beschränkt bleiben, sondern vor allem der Einfluss der europäischen Dimension dieser Thematik miteinbezogen werden. Auf europäischer Ebene zeigt sich eine Position zu Gunsten der Kernenergie. Unter den 27 EU-Staaten findet gerade eine Renaissance der Atomkraft statt. Die drei europäischen Organe befürworten den umfangreichen Einsatz der Kernenergie als langfristigen Bestandteil des Energieträgermix. Deutschland gehört mit seinem Beschluss zum Atomausstieg einer Minderheit an. Als Teil eines immer stärker zusammen wachsenden und letztendlich vollständig integrierten europäischen Strommarktes wird Deutschland langfristig stets mit Atomstrom versorgt werden. Dies gilt losgelöst von dem Einsatz von Kernkraftwerken im Inland. Eine Abschaltung der Anlagen führt damit nicht zur Zielerreichung der Atomkraftgegner, sondern lediglich zu zusätzlichen energietechnischen Herausforderungen bei der Sicherstellung der deutschen Stromversorgung. Der deutsche Atomausstieg sollte aus diesem Grund von der neuen Bundesregierung zurück genommen werden. Y1 - 2009 SN - 1866-2765 U6 - http://dx.doi.org/10.1007/s12398-009-0039-4 VL - 33 IS - 4 SP - 341 EP - 350 PB - Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Schneider, Jules A1 - Schwabedal, Justus T. C. A1 - Bialonski, Stephan T1 - Schlafspindeln – Funktion, Detektion und Nutzung als Biomarker für die psychiatrische Diagnostik JF - Der Nervenarzt N2 - Hintergrund: Die Schlafspindel ist ein Graphoelement des Elektroenzephalogramms (EEG), das im Leicht- und Tiefschlaf beobachtet werden kann. Veränderungen der Spindelaktivität wurden für verschiedene psychiatrische Erkrankungen beschrieben. Schlafspindeln zeigen aufgrund ihrer relativ konstanten Eigenschaften Potenzial als Biomarker in der psychiatrischen Diagnostik. Methode: Dieser Beitrag liefert einen Überblick über den Stand der Wissenschaft zu Eigenschaften und Funktionen der Schlafspindeln sowie über beschriebene Veränderungen der Spindelaktivität bei psychiatrischen Erkrankungen. Verschiedene methodische Ansätze und Ausblicke zur Spindeldetektion werden hinsichtlich deren Anwendungspotenzial in der psychiatrischen Diagnostik erläutert. Ergebnisse und Schlussfolgerung: Während Veränderungen der Spindelaktivität bei psychiatrischen Erkrankungen beschrieben wurden, ist deren exaktes Potenzial für die psychiatrische Diagnostik noch nicht ausreichend erforscht. Diesbezüglicher Erkenntnisgewinn wird in der Forschung gegenwärtig durch ressourcenintensive und fehleranfällige Methoden zur manuellen oder automatisierten Spindeldetektion ausgebremst. Neuere Detektionsansätze, die auf Deep-Learning-Verfahren basieren, könnten die Schwierigkeiten bisheriger Detektionsmethoden überwinden und damit neue Möglichkeiten für die praktisch KW - Schlafspindeldetektion KW - Psychiatrische Biomarker KW - · Psychiatrische Erkrankungen/Diagnostik KW - Elektroenzephalographie KW - Deep Learning Y1 - 2022 U6 - http://dx.doi.org/10.1007/s00115-022-01340-z SN - 1433-0407 SP - 1 EP - 8 PB - Springer CY - Berlin, Heidelberg ER - TY - JOUR A1 - Heuermann, Holger A1 - Emmrich, Thomas A1 - Bongartz, Simon T1 - Microwave spark plug to support ignitions with high compression ratios JF - IEEE Transactions on Plasma Science N2 - Upcoming gasoline engines should run with a larger number of fuels beginning from petrol over methanol up to gas by a wide range of compression ratios and a homogeneous charge. In this article, the microwave (MW) spark plug, based on a high-speed frequency hopping system, is introduced as a solution, which can support a nitrogen compression ratio up to 1:39 in a chamber and more. First, an overview of the high-speed frequency hopping MW ignition and operation system as well as the large number of applications are presented. Both gives an understanding of this new base technology for MW plasma generation. Focus of the theoretical part is the explanation of the internal construction of the spark plug, on the achievable of the high voltage generation as well as the high efficiency to hold the plasma. In detail, the development process starting with circuit simulations and ending with the numerical multiphysics field simulations is described. The concept is evaluated with a reference prototype covering the frequency range between 2.40 and 2.48 GHz and working over a large power range from 20 to 200 W. A larger number of different measurements starting by vector hot-S11 measurements and ending by combined working scenarios out of hot temperature, high pressure and charge motion are winding up the article. The limits for the successful pressure tests were given by the pressure chamber. Pressures ranged from 1 to 39 bar and charge motion up to 25 m/s as well as temperatures from 30◦ to 125◦. KW - Automotive application KW - ignition KW - microplasma KW - microwave (MW) plasma KW - plasma jet Y1 - 2022 U6 - http://dx.doi.org/10.1109/TPS.2022.3183690 SN - 1939-9375 IS - Early Access SP - 1 EP - 6 PB - IEEE ER - TY - JOUR A1 - Emhardt, Selina N. A1 - Jarodzka, Halszka A1 - Brand-Gruwel, Saskia A1 - Drumm, Christian A1 - Niehorster, Diederick C. A1 - van Gog, Tamara T1 - What is my teacher talking about? Effects of displaying the teacher’s gaze and mouse cursor cues in video lectures on students’ learning JF - Journal of Cognitive Psychology N2 - Eye movement modelling examples (EMME) are instructional videos that display a teacher’s eye movements as “gaze cursor” (e.g. a moving dot) superimposed on the learning task. This study investigated if previous findings on the beneficial effects of EMME would extend to online lecture videos and compared the effects of displaying the teacher’s gaze cursor with displaying the more traditional mouse cursor as a tool to guide learners’ attention. Novices (N = 124) studied a pre-recorded video lecture on how to model business processes in a 2 (mouse cursor absent/present) × 2 (gaze cursor absent/present) between-subjects design. Unexpectedly, we did not find significant effects of the presence of gaze or mouse cursors on mental effort and learning. However, participants who watched videos with the gaze cursor found it easier to follow the teacher. Overall, participants responded positively to the gaze cursor, especially when the mouse cursor was not displayed in the video. KW - Instructional design KW - eye movement modelling examples KW - video learning Y1 - 2022 U6 - http://dx.doi.org/10.1080/20445911.2022.2080831 SN - 2044-5911 SP - 1 EP - 19 PB - Routledge, Taylor & Francis Group CY - Abingdon ER -