TY - CHAP A1 - Kraft, Bodo A1 - Retkowitz, Daniel T1 - Graph Transformations for Dynamic Knowledge Processing N2 - In: Proceedings of the 39th Annual Hawaii International Conference on System Sciences, 2006. HICSS '06 http://dx.doi.org/10.1109/HICSS.2006.200 The conceptual design phase at the beginning of the building construction process is not adequately supported by any CAD-tool. Conceptual design support needs regarding two aspects: first, the architect must be able to develop conceptual sketches that provide abstraction from constructive details. Second, conceptually relevant knowledge should be available to check these conceptual sketches. The paper deals with knowledge to formalize for conceptual design. To enable domain experts formalizing knowledge, a graph-based specification is presented that allows the development of a domain ontology and design rules specific for one class of buildings at runtime. The provided tool support illustrates the introduced concepts and demonstrates the consistency analysis between knowledge and conceptual design. KW - CAD KW - CAD KW - Bauingenieurwesen KW - CAD KW - civil engineering Y1 - 2006 ER - TY - CHAP A1 - Kraft, Bodo A1 - Retkowitz, Daniel T1 - Rule-Dependencies for Visual Knowledge Specification in Conceptual Design N2 - In: Proc. of the 11th Intl. Conf. on Computing in Civil and Building Engineering (ICCCBE-XI) ed. Hugues Rivard, Montreal, Canada, Seite 1-12, ACSE (CD-ROM), 2006 Currently, the conceptual design phase is not adequately supported by any CAD tool. Neither the support while elaborating conceptual sketches, nor the automatic proof of correctness with respect to effective restrictions is currently provided by any commercial tool. To enable domain experts to store the common as well as their personal domain knowledge, we develop a visual language for knowledge formalization. In this paper, a major extension to the already existing concepts is introduced. The possibility to define rule dependencies extends the expressiveness of the knowledge definition language and contributes to the usability of our approach. KW - CAD KW - CAD KW - Bauingenieurwesen KW - CAD KW - civil engineering Y1 - 2006 ER - TY - CHAP A1 - Näther, Niko A1 - Poghossian, Arshak A1 - Platen, J. A1 - Yoshinobu, T. A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - Multi-parameter sensing of both physical and (bio-)chemical quantities using the same transducer principle T2 - Biochemical sensing utilisation of micro- and nanotechnologies : Warsaw, [23rd - 26th] November 2005 / ed. by M. Mascini ... Y1 - 2006 SP - 172 EP - 181 CY - Warsaw ER - TY - CHAP A1 - Kloock, Joachim P. A1 - Schubert, J. A1 - Ermelenko, Y. A1 - Vlasov, Y. G. A1 - Bratov, A. A1 - Schöning, Michael Josef T1 - Thin-film sensors with chalcogenide glass materials – a general survey T2 - Biochemical sensing utilisation of micro- and nanotechnologies : Warsaw, [23rd - 26th] November 2005 / ed. by M. Mascini ... Y1 - 2006 SP - 92 EP - 97 CY - Warsaw ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Abouzar, Maryam H. A1 - Wagner, Torsten A1 - Näther, Niko A1 - Rolka, David A1 - Yoshinobu, Tatsuo A1 - Kloock, Joachim P. A1 - Turek, Monika A1 - Ingebrandt, Sven A1 - Poghossian, Arshak T1 - A semiconductor-based field-effect platform for (bio-)chemical and physical sensors: From capacitive EIS sensors and LAPS over ISFETs to nano-scale devices T2 - MRS Proceedings Y1 - 2006 U6 - http://dx.doi.org/10.1557/PROC-0952-F08-02 N1 - Vol. 952 - Symposium F - Integrated Nanosensors SP - 1 EP - 9 ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Abouzar, Maryam H. A1 - Han, Y. A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Poghossian, Arshak T1 - Markierungsfreie DNA-Detektion mit Silizium-Feldeffektsensoren – Messeffekte oder Artefakte? T2 - Sensoren und Mess-Systeme 2006 : Vorträge der 13. ITG/GMA-Fachtagung vom 13. bis 14.3.2006 in Freiburg/Breisgau Y1 - 2006 SN - 3-8007-2939-3 SP - 443 EP - 446 PB - VDE Verl. CY - Berlin ER - TY - CHAP A1 - Platen, J. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Präparation von selbstjustierenden Nanostrukturen mittels Schichtausdehnungstechnik T2 - Sensoren und Mess-Systeme 2006 : Vorträge der 13. ITG/GMA-Fachtagung vom 13. bis 14.3.2006 in Freiburg/Breisgau Y1 - 2006 SN - 3-8007-2939-3 SP - 277 EP - 280 PB - VDE Verl. CY - Berlin ER - TY - CHAP A1 - Wagner, Torsten A1 - Yoshinobu, T. A1 - Otto, R. A1 - Rao, C. A1 - Molina, R. A1 - Schöning, Michael Josef T1 - Licht-adressierbare potentiometrische Sensorsysteme – Konzepte und Anwendungen T2 - Sensoren und Mess-Systeme 2006 : Vorträge der 13. ITG/GMA-Fachtagung vom 13. bis 14.3.2006 in Freiburg/Breisgau Y1 - 2006 SN - 3-8007-2939-3 SP - 165 EP - 168 PB - VDE Verl. CY - Berlin ER - TY - CHAP A1 - Poghossian, Arshak A1 - Schumacher, Kerstin A1 - Kloock, Joachim P. A1 - Rosenkranz, Christian A1 - Schultze, Joachim W. A1 - Müller-Veggian, Mattea A1 - Schöning, Michael Josef T1 - Functional testing and characterisation of ISFETs on wafer level by means of a micro-droplet cell N2 - A wafer-level functionality testing and characterisation system for ISFETs (ionsensitive field-effect transistor) is realised by means of integration of a specifically designed capillary electrochemical micro-droplet cell into a commercial wafer prober-station. The developed system allows the identification and selection of “good” ISFETs at the earliest stage and to avoid expensive bonding, encapsulation and packaging processes for nonfunctioning ISFETs and thus, to decrease costs, which are wasted for bad dies. The developed system is also feasible for wafer-level characterisation of ISFETs in terms of sensitivity, hysteresis and response time. Additionally, the system might be also utilised for wafer-level testing of further electrochemical sensors. KW - Biosensor KW - Biosensorik KW - ISFET KW - Wafer KW - ISFET KW - wafer-level testing KW - capillary micro-droplet cell Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1259 ER - TY - CHAP A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Preface of the Special Issue of I3S 2005 in Jülich (Germany) N2 - International Symposium on Sensor Science, I3S 2005 <3; 2005; Juelich, Germany> In: Sensors 2006, 6, 260-261 ISSN 1424-8220 KW - Biosensor KW - I3S 2005 KW - International Symposium on Sensor Science Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1365 ER - TY - CHAP A1 - Srivastava, Alok A1 - Singh, Virendra A1 - Dhand, Chetna A1 - Kaur, Manindar A1 - Singh, Tejvir A1 - Witte, Katrin A1 - Scherer, Ulrich W. T1 - Study of swift heavy ion modified conduction polymer composites for application as gas sensor N2 - A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas. KW - Biosensor KW - Conducing polymer KW - ammonia gas sensors KW - swift heavy ions KW - polymer composites Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1345 ER - TY - CHAP A1 - Chaiyboun, Ali A1 - Traute, Rüdiger A1 - Kiesewetter, Olaf A1 - Ahlers, Simon A1 - Müller, Gerhard A1 - Doll, Theodor T1 - Modular analytical multicomponent analysis in gas sensor arrays N2 - A multi-sensor system is a chemical sensor system which quantitatively and qualitatively records gases with a combination of cross-sensitive gas sensor arrays and pattern recognition software. This paper addresses the issue of data analysis for identification of gases in a gas sensor array. We introduce a software tool for gas sensor array configuration and simulation. It concerns thereby about a modular software package for the acquisition of data of different sensors. A signal evaluation algorithm referred to as matrix method was used specifically for the software tool. This matrix method computes the gas concentrations from the signals of a sensor array. The software tool was used for the simulation of an array of five sensors to determine gas concentration of CH4, NH3, H2, CO and C2H5OH. The results of the present simulated sensor array indicate that the software tool is capable of the following: (a) identify a gas independently of its concentration; (b) estimate the concentration of the gas, even if the system was not previously exposed to this concentration; (c) tell when a gas concentration exceeds a certain value. A gas sensor data base was build for the configuration of the software. With the data base one can create, generate and manage scenarios and source files for the simulation. With the gas sensor data base and the simulation software an on-line Web-based version was developed, with which the user can configure and simulate sensor arrays on-line. KW - Biosensor KW - Main sensitivity KW - cross sensitivity KW - matrix method KW - gas sensor array KW - modelling Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1358 ER - TY - CHAP A1 - Sakthivel, Mariappan A1 - Weppner, Werner T1 - Response behaviour of a hydrogen sensor based on ionic conducting polymer-metal interfaces prepared by the chemical reduction method N2 - A solid-state amperometric hydrogen sensor based on a protonated Nafion membrane and catalytic active electrode operating at room temperature was fabricated and tested. Ionic conducting polymer-metal electrode interfaces were prepared chemically by using the impregnation-reduction method. The polymer membrane was impregnated with tetra-ammine platinum chloride hydrate and the metal ions were subsequently reduced by using either sodium tetrahydroborate or potassium tetrahydroborate. The hydrogen sensing characteristics with air as reference gas is reported. The sensors were capable of detecting hydrogen concentrations from 10 ppm to 10% in nitrogen. The response time was in the range of 10-30 s and a stable linear current output was observed. The thin Pt films were characterized by XRD, Infrared Spectroscopy, Optical Microscopy, Atomic Force Microscopy, Scanning Electron Microscopy and EDAX. KW - Biosensor KW - Hydrogen sensor KW - amperometric sensor KW - porous Pt electrode KW - chemical reduction method Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1399 ER - TY - CHAP A1 - Koplin, Tobias J. A1 - Siemons, Maike A1 - Océn-Valéntin, César A1 - Sanders, Daniel A1 - Simon, Ulrich T1 - Workflow for high throughput screening of gas sensing materials N2 - The workflow of a high throughput screening setup for the rapid identification of new and improved sensor materials is presented. The polyol method was applied to prepare nanoparticular metal oxides as base materials, which were functionalised by surface doping. Using multi-electrode substrates and high throughput impedance spectroscopy (HT-IS) a wide range of materials could be screened in a short time. Applying HT-IS in search of new selective gas sensing materials a NO2-tolerant NO sensing material with reduced sensitivities towards other test gases was identified based on iridium doped zinc oxide. Analogous behaviour was observed for iridium doped indium oxide. KW - Biosensor KW - High throughput experimentation KW - gas sensor KW - metal oxide KW - doping KW - impedance spectroscopy KW - nitrogen oxides Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1407 ER - TY - CHAP A1 - Näther, Niko A1 - Juárez, Leon M. A1 - Emmerich, Rüdiger A1 - Berger, Jörg A1 - Friedrich, Peter A1 - Schöning, Michael Josef T1 - Detection of hydrogen peroxide (H2O2) at exposed temperatures for industrial processes N2 - An H2O2 sensor for the application in industrial sterilisation processes has been developed. Therefore, automated sterilisation equipment at laboratory scale has been constructed using parts from industrial sterilisation facilities. In addition, a software tool has been developed for the control of the sterilisation equipment at laboratory scale. First measurements with the developed sensor set-up as part of the sterilisation equipment have been performed and the sensor has been physically characterised by optical microscopy and SEM. KW - Biosensor KW - Gas sensor KW - hydrogen peroxide KW - sterilisation KW - catalytic decomposition Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1418 ER - TY - CHAP A1 - Wagner, Thorsten A1 - Kohl, Claus-Dieter A1 - Fröba, Michael A1 - Tiemann, Michael T1 - Gas sensing properties of ordered mesoporous SnO2 N2 - We report on the synthesis and CO gas-sensing properties of mesoporous tin(IV) oxides (SnO2). For the synthesis cetyltrimethylammonium bromide (CTABr) was used as a structure-directing agent; the resulting SnO2 powders were applied as films to commercially available sensor substrates by drop coating. Nitrogen physisorption shows specific surface areas up to 160 m2·g-1 and mean pore diameters of about 4 nm, as verified by TEM. The film conductance was measured in dependence on the CO concentration in humid synthetic air at a constant temperature of 300 °C. The sensors show a high sensitivity at low CO concentrations and turn out to be largely insensitive towards changes in the relative humidity. We compare the materials with commercially available SnO2-based sensors. KW - Biosensor KW - Tin oxide KW - sensing properties KW - CO KW - humidity Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1422 ER - TY - CHAP A1 - Mirmohseni, Abdolreza A1 - Rostamizadeh, Kobra T1 - Quartz crystal nanobalance in conjunction with principal component analysis for identification of volatile organic compounds N2 - Quartz crystal nanobalance (QCN) sensors are considered as powerful masssensitive sensors to determine materials in the sub-nanogram level. In this study, a single piezoelectric quartz crystal nanobalance modified with polystyrene was employed to detect benzene, toluene, ethylbenzene and xylene (BTEX compounds). The frequency shift of the QCN sensor was found to be linear against the BTEX compound concentrations in the range about 1-45 mg l-1. The correlation coefficients for benzene, toluene, ethylbenzene, and xylene were 0.991, 0.9977, 0.9946 and 0.9971, respectively. The principal component analysis was also utilized to process the frequency response data of the single piezoelectric crystal at different times, considering to the different adsorption-desorption dynamics of BTEX compounds. Using principal component analysis, it was found that over 90% of the data variance could still be explained by use of two principal components (PC1 and PC2). Subsequently, the successful identification of benzene and toluene was possible through the principal component analysis of the transient responses of the polystyrene modified QCN sensor. The results showed that the polystyrene-modified QCN had favorable identification and quantification performances for the BTEX compounds. KW - Biosensor KW - Quartz crystal nanobalance (QCN) KW - BTEX compounds KW - principal component Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1434 ER - TY - CHAP A1 - Kreutz, Christian A1 - Lörgen, Jürgen A1 - Graewe, Boris A1 - Bargon, Joachim A1 - Yoshida, Mayumi A1 - Freso, Zachary M. A1 - Frèchet, Jean M. J. T1 - High frequency quartz micro balances: a promising path to enhanced sensitivity of gravimetric sensors N2 - An array of 50 MHz quartz microbalances (QMBs) coated with a dendronized polymer was used to detect small amounts of volatile organic compounds (VOCs) in the gas phase. The results were compared to those obtained with the commonly used 10 MHz QMBs. The 50 MHz QMBs proved to be a powerful tool for the detection of VOCs in the gas phase; therefore, they represent a promising alternative to the much more delicate surface acoustic wave devices (SAWs). KW - Biosensor KW - Quartz micro balances KW - electronic noses dendronized polymers inverted mesa technology Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1445 ER - TY - CHAP A1 - Rabner, Arthur A1 - Shacham, Yosi T1 - A concept for a sensitive micro total analysis system for high throughput fluorescence imaging N2 - This paper discusses possible methods for on-chip fluorescent imaging for integrated bio-sensors. The integration of optical and electro-optical accessories, according to suggested methods, can improve the performance of fluorescence imaging. It can boost the signal to background ratio by a few orders of magnitudes in comparison to conventional discrete setups. The methods that are present in this paper are oriented towards building reproducible arrays for high-throughput micro total analysis systems (µTAS). The first method relates to side illumination of the fluorescent material placed into microcompartments of the lab-on-chip. Its significance is in high utilization of excitation energy for low concentration of fluorescent material. The utilization of a transparent µLED chip, for the second method, allows the placement of the excitation light sources on the same optical axis with emission detector, such that the excitation and emission rays are directed controversly. The third method presents a spatial filtering of the excitation background. KW - Biosensor KW - Fluorescence KW - imaging KW - lab-on-chip KW - fluidic KW - lenslet array KW - LED chip KW - image sensor KW - biosensor Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1456 ER - TY - CHAP A1 - Förster, Arnold A1 - Stock, Jürgen A1 - Montanari, Simone A1 - Lepsa, Mihail Ion A1 - Lüth, Hans T1 - Fabrication and characterisation of GaAs Gunn Diode Chips for applications at 77 GHz in automotive industry N2 - GaAs-based Gunn diodes with graded AlGaAs hot electron injector heterostructures have been developed under the special needs in automotive applications. The fabrication of the Gunn diode chips was based on total substrate removal and processing of integrated Au heat sinks. Especially, the thermal and RF behavior of the diodes have been analyzed by DC, impedance and S-parameter measurements. The electrical investigations have revealed the functionality of the hot electron injector. An optimized layer structure could fulfill the requirements in adaptive cruise control (ACC) systems at 77 GHz with typical output power between 50 and 90 mW. KW - Biosensor KW - Gunn diode KW - microwave generation KW - GaAs hot electron injector Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1462 ER -