TY - JOUR A1 - Molinnus, Denise A1 - Sorich, Maren A1 - Bartz, Alexander A1 - Siegert, Petra A1 - Willenberg, Holger S. A1 - Lisdat, Fred A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Towards an adrenaline biosensor based on substrate recycling amplification in combination with an enzyme logic gate JF - Sensors and Actuators B: Chemical N2 - An amperometric biosensor using a substrate recycling principle was realized for the detection of low adrenaline concentrations (1 nM) by measurements in phosphate buffer and Ringer’s solution at pH 6.5 and pH 7.4, respectively. In proof-of-concept experiments, a Boolean logic-gate principle has been applied to develop a digital adrenaline biosensor based on an enzyme AND logic gate. The obtained results demonstrate that the developed digital biosensor is capable for a rapid qualitative determination of the presence/absence of adrenaline in a YES/NO statement. Such digital biosensor could be used in clinical diagnostics for the control of a correct insertion of a catheter in the adrenal veins during adrenal venous-sampling procedure. Y1 - 2016 U6 - https://doi.org/10.1016/j.snb.2016.06.064 SN - 0925-4005 VL - 237 SP - 190 EP - 195 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Knobe, M. A1 - Giesen, M. A1 - Plate, S. A1 - Gradl-Dietsch, G. A1 - Buecking, B. A1 - Eschbach, D. A1 - Laack, Walter van A1 - Pape, H.-C. T1 - The Aachen mobility and balance index to measure physiological falls risk: a comparison with the Tinetti POMA scale JF - European Journal Of Trauma And Emergency Surgery N2 - Purpose The most commonly used mobility assessments for screening risk of falls among older adults are rating scales such as the Tinetti performance oriented mobility assessment (POMA). However, its correlation with falls is not always predictable and disadvantages of the scale include difficulty to assess many of the items on a 3-point scale and poor specificity. The purpose of this study was to describe the ability of the new Aachen Mobility and Balance Index (AMBI) to discriminate between subjects with a fall history and subjects without such events in comparison to the Tinetti POMA Scale. Methods For this prospective cohort study, 24 participants in the study group and 10 in the control group were selected from a population of patients in our hospital who had met the stringent inclusion criteria. Both groups completed the Tinetti POMA Scale (gait and balance component) and the AMBI (tandem stance, tandem walk, ten-meter-walk-test, sit-to-stand with five repetitions, 360° turns, timed-up-and-go-test and measurement of the dominant hand grip strength). A history of falls and hospitalization in the past year were evaluated retrospectively. The relationships among the mobility tests were examined with Bland–Altmananalysis. Receiver-operated characteristics curves, sensitivity and specificity were calculated. Results The study showed a strong negative correlation between the AMBI (17 points max., highest fall risk) and Tinetti POMA Scale (28 points max., lowest fall risk; r = −0.78, p < 0.001) with an excellent discrimination between community-dwelling older people and a younger control group. However, there were no differences in any of the mobility and balance measurements between participants with and without a fall history with equal characteristics in test comparison (AMBI vs. Tinetti POMA Scale: AUC 0.570 vs. 0.598; p = 0.762). The Tinetti POMA Scale (cut-off <20 points) showed a sensitivity of 0.45 and a specificity of 0.69, the AMBI a sensitivity of 0.64 and a specificity of 0.46 (cut-off >5 points). Conclusion The AMBI comprises mobility and balance tasks with increasing difficulty as well as a measurement of the dominant hand-grip strength. Its ability to identify fallers was comparable to the Tinetti POMA Scale. However, both measurement sets showed shortcomings in discrimination between fallers and non-fallers based on a self-reported retrospective falls-status. KW - Tinetti test KW - Mobility KW - Mobility tests KW - Ground-level falls KW - Elderly KW - Fall prevention KW - Co-managed care KW - Balance Y1 - 2016 U6 - https://doi.org/10.1007/s00068-016-0693-2 SN - 1863-9941 VL - 42 IS - 5 SP - 537 EP - 545 PB - Springer CY - Berlin ER - TY - JOUR A1 - Doll, Theodor A1 - Wagner, Torsten A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Engineering of functional interfaces / Theodor Doll ; Torsten Wagner ; Patrick Wagner ; Michael J. Schöning (eds.) JF - Physica status solidi (a) Y1 - 2016 U6 - https://doi.org/10.1002/pssa.201670641 SN - 1862-6319 VL - 213 IS - 6 SP - 1393 EP - 1394 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Wagner, Torsten A1 - Vornholt, Wolfgang A1 - Werner, Frederik A1 - Yoshinobu, Tatsuo A1 - Miyamoto, Ko-Ichiro A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Light-addressable potentiometric sensor (LAPS) combined with magnetic beads for pharmaceutical screening JF - Physics in medicine N2 - The light-addressable potentiometric sensor (LAPS) has the unique feature to address different regions of a sensor surface without the need of complex structures. Measurements at different locations on the sensor surface can be performed in a common analyte solution, which distinctly simplifies the fluidic set-up. However, the measurement in a single analyte chamber prevents the application of different drugs or different concentrations of a drug to each measurement spot at the same time as in the case of multi-reservoir-based set-ups. In this work, the authors designed a LAPS-based set-up for cell culture screening that utilises magnetic beads loaded with the endotoxin (lipopolysaccharides, LPS), to generate a spatially distributed gradient of analyte concentration. Different external magnetic fields can be adjusted to move the magnetic beads loaded with a specific drug within the measurement cell. By recording the metabolic activities of a cell layer cultured on top of the LAPS surface, this work shows the possibility to apply different concentrations of a sample along the LAPS measurement spots within a common analyte solution. Y1 - 2016 U6 - https://doi.org/10.1016/j.phmed.2016.03.001 SN - 2352-4510 VL - 2016 IS - 1 SP - 2 EP - 7 ER - TY - JOUR A1 - Miyamoto, Ko-Ichiro A1 - Sato, Takuya A1 - Abe, Minami A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Light-addressable potentiometric sensor as a sensing element in plug-based microfluidic devices JF - Micromachines N2 - A plug-based microfluidic system based on the principle of the light-addressable potentiometric sensor (LAPS) is proposed. The LAPS is a semiconductor-based chemical sensor, which has a free addressability of the measurement point on the sensing surface. By combining a microfluidic device and LAPS, ion sensing can be performed anywhere inside the microfluidic channel. In this study, the sample solution to be measured was introduced into the channel in a form of a plug with a volume in the range of microliters. Taking advantage of the light-addressability, the position of the plug could be monitored and pneumatically controlled. With the developed system, the pH value of a plug with a volume down to 400 nL could be measured. As an example of plug-based operation, two plugs were merged in the channel, and the pH change was detected by differential measurement. KW - light-addressable potentiometric sensor KW - plug-based microfluidic device KW - chemical sensor Y1 - 2016 U6 - https://doi.org/10.3390/mi7070111 SN - 2072-666X N1 - This article belongs to the Special Issue "Micro/Nano Devices for Chemical Analysis" VL - 7 IS - 7 SP - 111 PB - MDPI CY - Basel ER - TY - CHAP A1 - Evers, Jörg A1 - Fleischhaker, Robert A1 - Pálffy, A. A1 - Keitel, C. T1 - Light propagation : From atomic to nuclear quantum optics T2 - Modern optics and photonics: atoms and structured media Y1 - 2010 SN - 978-981431327-8 U6 - https://doi.org/10.1142/9789814313278_0001 SP - 3 EP - 15 PB - World Scientific Publishing Co. ER - TY - THES A1 - Fleischhaker, Robert T1 - Light propagation in dense and chiral media Y1 - 2009 N1 - Heidelberg, Univ., Diss., 2009 ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Evers, Jörg T1 - Phase-controlled pulse propagation in media with cross coupling of electric and magnetic probe field component JF - Physical Review A - Atomic, molecular, and optical physics Y1 - 2009 U6 - https://doi.org/10.1103/PHYSREVA.80.063816 SN - 1050-2947 VL - 80 IS - 6 SP - 063816 ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Evers, Jörg T1 - Four-wave mixing enhanced white-light cavity JF - Physical Review A - Atomic, molecular, and optical physics Y1 - 2008 SN - 0556-2791 VL - 78 IS - 5 SP - 051802(R) ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Evers, Jörg T1 - Nonlinear effects in pulse propagation through Doppler-broadened closed-loop atomic media JF - Physical Review A - Atomic, molecular, and optical physics Y1 - 2008 U6 - https://doi.org/10.1103/PhysRevA.77.043805 SN - 1050-2947 VL - 77 IS - 4 SP - 043805 ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Evers, Jörg A1 - Dey, Tarak N. T1 - Phase modulation induced by cooperative effects in electromagnetically induced transparency JF - Physical Review A - Atomic, molecular, and optical physics N2 - We analyze the influence of dipole-dipole interactions in an electromagnetically induced transparency set up for a density at the onset of cooperative effects. To this end, we include mean-field models for the influence of local-field corrections and radiation trapping into our calculation. We show both analytically and numerically that the polarization contribution to the local field strongly modulates the phase of a weak pulse. We give an intuitive explanation for this local-field-induced phase modulation and demonstrate that it distinctively differs from the nonlinear self-phase-modulation that a strong pulse experiences in a Kerr medium. Y1 - 2010 U6 - https://doi.org/10.1103/PhysRevA.82.013815 SN - 1050-2947 VL - 82 IS - 1 PB - AIP Publishing CY - Melville, NY ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Evers, Jörg T1 - A Maxwell–Schrödinger solver for quantum optical few-level systems JF - Computer Physics Communications N2 - The msprop program presented in this work is capable of solving the Maxwell–Schrödinger equations for one or several laser fields propagating through a medium of quantum optical few-level systems in one spatial dimension and in time. In particular, it allows to numerically treat systems in which a laser field interacts with the medium with both its electric and magnetic component at the same time. The internal dynamics of the few-level system is modeled by a quantum optical master equation which includes coherent processes due to optical transitions driven by the laser fields as well as incoherent processes due to decay and dephasing. The propagation dynamics of the laser fields is treated in slowly varying envelope approximation resulting in a first order wave equation for each laser field envelope function. The program employs an Adams predictor formula second order in time to integrate the quantum optical master equation and a Lax–Wendroff scheme second order in space and time to evolve the wave equations for the fields. The source function in the Lax–Wendroff scheme is specifically adapted to allow taking into account the simultaneous coupling of a laser field to the polarization and the magnetization of the medium. To reduce execution time, a customized data structure is implemented and explained. In three examples the features of the program are demonstrated and the treatment of a system with a phase-dependent cross coupling of the electric and magnetic field component of a laser field is shown. Y1 - 2011 U6 - https://doi.org/10.1016/j.cpc.2010.10.018 SN - 0010-4655 VL - 182 IS - 3 SP - 739 EP - 747 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Krauß, Nico A1 - Schättiger, Farina A1 - Dekorsy, Thomas T1 - Consistent characterization of semiconductor saturable absorber mirrors with singe-pulse and pump-probe spectroscopy JF - Optics Express Y1 - 2013 U6 - https://doi.org/10.1364/OE.21.006764 SN - 1094-4087 VL - 21 IS - 6 SP - 6764 EP - 6776 PB - Optica CY - Washington, DC ER - TY - CHAP A1 - Fleischhaker, Robert A1 - Gebs, Raphael A1 - Budnicki, Aleksander A1 - Wolf, M. A1 - Kleinbauer, Jochen A1 - Sutter, Dirk H. T1 - Compact gigawatt-class sub-picosecond Yb:YAG thin-disk regenerative chirped-pulse amplifier with high average power at up to 800 kHz T2 - Lasers and electro-optics europe (CLEO EUROPE/IQEC) : International quantum electronics conference : 12 - 16 May 2013, Munich, GE. Y1 - 2013 SN - 978-1-4799-0593-5 U6 - https://doi.org/10.1109/CLEOE-IQEC.2013.6801054 N1 - Lasers and Electro-Optics Europe (CLEO EUROPE/IQEC) <5, 2013, Munich, GE> PB - IEEE Computer Society ER - TY - CHAP A1 - Heckl, O. H. A1 - Weiler, Sascha A1 - Fleischhaker, Robert A1 - Gebs, Raphael A1 - Budnicki, Aleksander A1 - Wolf, M. A1 - Kleinbauer, Jochen A1 - Russ, S. A1 - Kumkar, M. A1 - Sutter, Dirk H. ED - Heisterkamp, Alexander ED - Herman, Peter R. ED - Meunier, Michael ED - Nolte, Stefan T1 - Industry-grade high average power femtosecond light source T2 - Frontiers in ultrafast optics: Biomedical, scientific, and industrial applications XIV : 1 Februar 2014, San Francisco, USA. - (SPIE proceedings series ; 8972) Y1 - 2014 U6 - https://doi.org/10.1117/12.2039337 N1 - Frontiers in Ultrafast Optics: Biomedical, Scientific, and Industrial Applications XIV <2, 2014, San Francisco, CA> SP - 89720P EP - 89720P-7 PB - SPIE, International Society for Optical Engineering ER - TY - CHAP A1 - Pricking, Sebastian A1 - Gebs, Raphael A1 - Fleischhaker, Robert A1 - Kleinbauer, Jochen A1 - Budnicki, Aleksander A1 - Sutter, Dirk A1 - Killi, Alexander A1 - Weiler, Sascha A1 - Mielke, M. A1 - Beaudou, B. A1 - Debord, B. A1 - Gerome, F. A1 - Benabid, F. ED - Dorsch, Friedhelm T1 - Hollow core fiber delivery of sub-ps pulses from a TruMicro 5000 Femto edition thin disk amplifier T2 - High-power laser materials processing: Lasers, beam delivery, diagnostics, and applications IV : 7 Februar 2015, San Francisco, USA. - (SPIE proceedings series ; 9356) Y1 - 2015 SN - 978-162841446-2 U6 - https://doi.org/10.1117/12.2079289 SN - 0277-786X SP - 935602 PB - SPIE, International Society for Optical Engineering ER - TY - JOUR A1 - Mahmoudi, Mohammad A1 - Fleischhaker, Robert A1 - Sahrai, Mostafa A1 - Evers, Jörg T1 - Group velocity control in the ultraviolet domain via interacting dark-state resonances JF - Journal of physics B: Atomic, molecular and optical physics Y1 - 2008 U6 - https://doi.org/10.1088/0953-4075/41/2/025504 SN - 0953-4075 SN - 1361-6455 VL - 41 IS - 2 SP - 25504 EP - 25600 ER - TY - CHAP A1 - Hüning, Felix T1 - Power Semiconductors for the automotive 48V board net T2 - PCIM Europe 2016 Conference Proceedings Y1 - 2016 SN - 978-3-8007-4186-1 SP - 1963 EP - 1969 PB - VDE Verl. CY - Berlin ER - TY - CHAP A1 - Schreiber, Marc A1 - Kraft, Bodo A1 - Zündorf, Albert T1 - Cost-efficient quality assurance of natural language processing tools through continuous monitoring with continuous integration T2 - 3rd International Workshop on Software Engineering Research and Industrial Practice Y1 - 2016 U6 - https://doi.org/10.1145/2897022.2897029 N1 - SER&IP’16, May 17 2016, Austin, TX, USA SP - 46 EP - 52 ER - TY - JOUR A1 - Wegmann, Kilian A1 - Hackl, Michael A1 - Staat, Manfred A1 - Mayer, Katharina A1 - Müller, Lars-Peter T1 - Double plate osteosynthesis of proximal ulna fractures: biomechanical and clinical results JF - Knee surgery, sports traumatology, arthroscopy N2 - While plate fixation of proximal ulna fractures might lead to superior clinical results compared to tension band wiring, regular plates represent an established risk factor for wound complications. The olecranon double plates (Medartis, Basel, CH) might decrease complications related to the osteosynthesis because of their low profile and better anatomical fit. This study aimed to evaluate the biomechanical performance and clinical results of the olecranon double plates. Y1 - 2016 U6 - https://doi.org/10.1007/s00167-016-4079-0 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 58 EP - 59 PB - Springer CY - Berlin ER -