TY - CHAP A1 - Arida, Hassan A. A1 - Kloock, Joachim P. A1 - Schöning, Michael Josef T1 - Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations N2 - A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors. KW - Biosensor KW - Heavy metal detection KW - thin-film microsensors KW - organic PVC membranes Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1545 ER - TY - JOUR A1 - Arida, Hassan A1 - Mohsen, Q. A1 - Schöning, Michael Josef T1 - Microfabrication, characterization and analytical application of a new thin-film silver microsensor JF - Electrochimica Acta. 54 (2009), H. 13 Y1 - 2009 SN - 0013-4686 SP - 3543 EP - 3547 ER - TY - JOUR A1 - Arida, Hassan A1 - Turek, Monika A1 - Rolka, David A1 - Schöning, Michael Josef T1 - A Novel Thin-Film Copper Array Based on an Organic/Inorganic Sensor Hybrid: Microfabrication, Potentiometric Characterization, and Flow-Injection Analysis Application JF - Electroanalysis. 21 (2009), H. 10 Y1 - 2009 SN - 1040-0397 SP - 1145 EP - 1151 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Arreola, Julio A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Effect of O2 plasma on properties of electrolyte-insulator-semiconductor structures JF - physica status solidi a : applications and materials sciences N2 - Prior to immobilization of biomolecules or cells onto biosensor surfaces, the surface must be physically or chemically activated for further functionalization. Organosilanes are a versatile option as they facilitate the immobilization through their terminal groups and also display self-assembly. Incorporating hydroxyl groups is one of the important methods for primary immobilization. This can be done, for example, with oxygen plasma treatment. However, this treatment can affect the performance of the biosensors and this effect is not quite well understood for surface functionalization. In this work, the effect of O2 plasma treatment on EIS sensors was investigated by means of electrochemical characterizations: capacitance–voltage (C–V) and constant capacitance (ConCap) measurements. After O2 plasma treatment, the potential of the EIS sensor dramatically shifts to a more negative value. This was successfully reset by using an annealing process. KW - surface functionalization KW - O2 plasma KW - hydroxylation KW - electrolyte-insulator semiconductor sensor (EIS) KW - annealing Y1 - 2017 U6 - http://dx.doi.org/10.1002/pssa.201700025 SN - 1862-6319 VL - 214 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Arreola, Julio A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Toward an immobilization method for spore-based biosensors in oxidative environment JF - Electrochimica Acta Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.electacta.2019.01.148 VL - 302 SP - 394 EP - 401 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Arreola, Julio A1 - Keusgen, Michael A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Combined calorimetric gas- and spore-based biosensor array for online monitoring and sterility assurance of gaseous hydrogen peroxide in aseptic filling machines JF - Biosensors and Bioelectronics Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.bios.2019.111628 SN - 0956-5663 VL - 143 IS - 111628 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Arreola, Julio A1 - Mätzkow, Malte A1 - Durán, Marlena Palomar A1 - Greeff, Anton A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Optimization of the immobilization of bacterial spores on glass substrates with organosilanes JF - Physica status solidi (A) : Applications and materials science N2 - Spores can be immobilized on biosensors to function as sensitive recognition elements. However, the immobilization can affect the sensitivity and reproducibility of the sensor signal. In this work, three different immobilization strategies with organosilanes were optimized and characterized to immobilize Bacillus atrophaeus spores on glass substrates. Five different silanization parameters were investigated: nature of the solvent, concentration of the silane, silanization time, curing process, and silanization temperature. The resulting silane layers were resistant to a buffer solution (e.g., Ringer solution) with a polysorbate (e.g., Tween®80) and sonication. KW - silanization KW - organosilanes KW - immobilization KW - endospores KW - biosensors KW - Bacillus atrophaeus Y1 - 2016 U6 - http://dx.doi.org/10.1002/pssa.201532914 SN - 1862-6319 VL - 213 IS - 6 SP - 1463 EP - 1470 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Arreola, Julio A1 - Oberländer, Jan A1 - Mätzkow, M. A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Surface functionalization for spore-based biosensors with organosilanes JF - Electrochimica Acta N2 - In the present work, surface functionalization of different sensor materials was studied. Organosilanes are well known to serve as coupling agent for biomolecules or cells on inorganic materials. 3-aminopropyltriethoxysilane (APTES) was used to attach microbiological spores time to an interdigitated sensor surface. The functionality and physical properties of APTES were studied on isolated sensor materials, namely silicon dioxide (SiO2) and platinum (Pt) as well as the combined material on sensor level. A predominant immobilization of spores could be demonstrated on SiO2 surfaces. Additionally, the impedance signal of APTES-functionalized biosensor chips has been investigated. Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.electacta.2017.04.157 SN - 0013-4686 VL - 241 SP - 237 EP - 243 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bandodkar, Amay J. A1 - Molinnus, Denise A1 - Mirza, Omar A1 - Guinovart, Tomas A1 - Windmiller, Joshua R. A1 - Valdes-Ramirez, Gabriela A1 - Andrade, Francisco J. A1 - Schöning, Michael Josef A1 - Wang, Joseph T1 - Epidermal tattoo potentiometric sodium sensors with wireless signal transduction for continuous non-invasive sweat monitoring JF - Biosensors and bioelectronics N2 - This article describes the fabrication, characterization and application of an epidermal temporary-transfer tattoo-based potentiometric sensor, coupled with a miniaturized wearable wireless transceiver, for real-time monitoring of sodium in the human perspiration. Sodium excreted during perspiration is an excellent marker for electrolyte imbalance and provides valuable information regarding an individual's physical and mental wellbeing. The realization of the new skin-worn non-invasive tattoo-like sensing device has been realized by amalgamating several state-of-the-art thick film, laser printing, solid-state potentiometry, fluidics and wireless technologies. The resulting tattoo-based potentiometric sodium sensor displays a rapid near-Nernstian response with negligible carryover effects, and good resiliency against various mechanical deformations experienced by the human epidermis. On-body testing of the tattoo sensor coupled to a wireless transceiver during exercise activity demonstrated its ability to continuously monitor sweat sodium dynamics. The real-time sweat sodium concentration was transmitted wirelessly via a body-worn transceiver from the sodium tattoo sensor to a notebook while the subjects perspired on a stationary cycle. The favorable analytical performance along with the wearable nature of the wireless transceiver makes the new epidermal potentiometric sensing system attractive for continuous monitoring the sodium dynamics in human perspiration during diverse activities relevant to the healthcare, fitness, military, healthcare and skin-care domains. Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.bios.2013.11.039 SN - 1873-4235 (E-Journal); 0956-5663 (Print) VL - 54 SP - 603 EP - 609 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Beging, Stefan A1 - Leinhos, Marcel A1 - Jablonski, Melanie A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Studying the spatially resolved immobilisation of enzymes on a capacitive field-effect structure by means of nano-spotting JF - Physica status solidi (a) Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431891 SN - 1862-6319 VL - 212 IS - 6 SP - 1353 EP - 1358 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Beging, Stefan A1 - Mlynek, Daniela A1 - Hataihimakul, Sudkanung A1 - Poghossian, Arshak A1 - Baldsiefen, Gerhard A1 - Busch, Heinz A1 - Laube, Norbert A1 - Kleinen, Lisa A1 - Schöning, Michael Josef T1 - Field-effect calcium sensor for the determination of the risk of urinary stone formation JF - Sensors and Actuators B: Chemical. 144 (2010), H. 2 Y1 - 2010 N1 - 22nd International Conference on Eurosensors - Dresden, Germany, 7-10 September 2008 ; Eurosensors ; (22, 2008, Dresden) SP - 374 EP - 379 ER - TY - CHAP A1 - Beging, Stefan A1 - Poghossian, Arshak A1 - Mlynek, D. A1 - Hataihimakul, S. A1 - Pedraza, A. A1 - Dhawan, S. A1 - Laube, N. A1 - Kleinen, L. A1 - Baldsiefen, G. A1 - Busch, H. A1 - Schöning, Michael Josef T1 - Ion-selective sensors for the determination of the risk of urinary stone formation T2 - Micro- and Nanosystems in biochemical diagnosis : Principles and applications Y1 - 2010 SP - 74 EP - 80 CY - Warsaw ER - TY - JOUR A1 - Beging, Stefan A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Hataihimakul, Sudkanung A1 - Busch, H. A1 - Baldsiefen, G. A1 - Laube, N. A1 - Kleinen, L. A1 - Hosseiny, R. T1 - Feldeffektbasierender Ca2+-sensitiver Sensor für den Einsatz im Nativurin zur Bestimmung des Harnsteinbildungsrisikos JF - Sensoren und Messsysteme 2008 : 14. Fachtagung Ludwigsburg, 11. und 12. März 2008 / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2008 SN - 978-3-18-092011-5 N1 - VDI-Berichte ; 2011 ; Sensoren und Messsysteme 2008, 14. GMA/ITG-Fachtagung, VDI/VDE- Gesellschaft Mess- und Automatisierungstechnik, + CD-ROM, Ludwigsburg, DE, 11.-12. Mar, 2008 SP - 775 EP - 782 PB - VDI-Verl. CY - Düsseldorf ER - TY - PAT A1 - Berger, Eric G. A1 - Biselli, Manfred A1 - Dinter, André A1 - Eisenkrätzer, Detlef A1 - Kiesewetter, André A1 - Zeng, Steffen T1 - Chinese-Hamster-Ovary-Zellen zur Produktion von Proteinen T1 - Chinese hamster ovary cells, useful for large-scale production of recombinant proteins, especially enzymes Y1 - 2000 N1 - DE000019847422C1 13.01.2000 EP000001121417A2 08.08.2001 WO002000022096A9 24.08.2000 SP - 1 EP - 6 ER - TY - JOUR A1 - Bertz, Morten A1 - Molinnus, Denise A1 - Schöning, Michael Josef A1 - Homma, Takayuki T1 - Real-time monitoring of H₂O₂ sterilization on individual bacillus atrophaeus spores by optical sensing with trapping Raman spectroscopy JF - Chemosensors N2 - Hydrogen peroxide (H₂O₂), a strong oxidizer, is a commonly used sterilization agent employed during aseptic food processing and medical applications. To assess the sterilization efficiency with H₂O₂, bacterial spores are common microbial systems due to their remarkable robustness against a wide variety of decontamination strategies. Despite their widespread use, there is, however, only little information about the detailed time-resolved mechanism underlying the oxidative spore death by H₂O₂. In this work, we investigate chemical and morphological changes of individual Bacillus atrophaeus spores undergoing oxidative damage using optical sensing with trapping Raman microscopy in real-time. The time-resolved experiments reveal that spore death involves two distinct phases: (i) an initial phase dominated by the fast release of dipicolinic acid (DPA), a major spore biomarker, which indicates the rupture of the spore’s core; and (ii) the oxidation of the remaining spore material resulting in the subsequent fragmentation of the spores’ coat. Simultaneous observation of the spore morphology by optical microscopy corroborates these mechanisms. The dependence of the onset of DPA release and the time constant of spore fragmentation on H₂O₂ shows that the formation of reactive oxygen species from H₂O₂ is the rate-limiting factor of oxidative spore death. KW - DPA (dipicolinic acid) KW - sterilization KW - Bacillus atrophaeus spores KW - optical trapping KW - Raman spectroscopy KW - optical sensor setup Y1 - 2023 U6 - http://dx.doi.org/10.3390/chemosensors11080445 SN - 2227-9040 N1 - This article belongs to the Special Issue "Biosensors and Chemical Sensors for Food and Healthcare Monitoring—Celebrating the 10th Anniversary" VL - 8 IS - 11 PB - MDPI CY - Basel ER - TY - JOUR A1 - Bertz, Morten A1 - Schöning, Michael Josef A1 - Molinnus, Denise A1 - Homma, Takayuki T1 - Influence of temperature, light, and H₂O₂ concentration on microbial spore inactivation: in-situ Raman spectroscopy combined with optical trapping JF - Physica status solidi (a) applications and materials science N2 - To gain insight on chemical sterilization processes, the influence of temperature (up to 70 °C), intense green light, and hydrogen peroxide (H₂O₂) concentration (up to 30% in aqueous solution) on microbial spore inactivation is evaluated by in-situ Raman spectroscopy with an optical trap. Bacillus atrophaeus is utilized as a model organism. Individual spores are isolated and their chemical makeup is monitored under dynamically changing conditions (temperature, light, and H₂O₂ concentration) to mimic industrially relevant process parameters for sterilization in the field of aseptic food processing. While isolated spores in water are highly stable, even at elevated temperatures of 70 °C, exposure to H₂O₂ leads to a loss of spore integrity characterized by the release of the key spore biomarker dipicolinic acid (DPA) in a concentration-dependent manner, which indicates damage to the inner membrane of the spore. Intensive light or heat, both of which accelerate the decomposition of H₂O₂ into reactive oxygen species (ROS), drastically shorten the spore lifetime, suggesting the formation of ROS as a rate-limiting step during sterilization. It is concluded that Raman spectroscopy can deliver mechanistic insight into the mode of action of H₂O₂-based sterilization and reveal the individual contributions of different sterilization methods acting in tandem. KW - hydrogen peroxide KW - optical spore trapping KW - Raman spectroscopy KW - sterilization conditions KW - temperature Y1 - 2024 U6 - http://dx.doi.org/10.1002/pssa.202300866 SN - 1862-6319 (Online) SN - 1862-6300 (Print) IS - Early View PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Biselli, Manfred A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Schnitzler, Thomas A1 - Zang, Werner A1 - Wagner, P. T1 - Entwicklung eines modularen festkörperbasierten Sensorsystems für die Überwachung von Zellkulturfermenationen JF - Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vorträge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in Nürnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA) Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Fachtagung Sensoren und Messsysteme 15, 2010, Nürnberg ; Gesellschaft Mess- und Automatisierungstechnik SP - 688 EP - 691 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Bohrn, U. A1 - Stütz, E. A1 - Fleischer, M. A1 - Schöning, Michael Josef T1 - Real-time detection of CO by eukaryotic cells JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference SP - 17 EP - 20 ER - TY - CHAP A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Stütz, Evamaria A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Detection of toxic chromium species in water using cellbased sensor systems Y1 - 2012 SN - 978-3-9813484-2-2 U6 - http://dx.doi.org/10.5162/IMCS2012/P2.1.14 SP - 1364 EP - 1367 ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Trattner, Barbara A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Stütz, Evamaria A1 - Schmitt-Landsiedel, Doris A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - A critical comparison of cell-based sensor systems for the detection of Cr (VI) in aquatic environment JF - Sensors and actuators. B: Chemical Y1 - 2013 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - Vol. 182 SP - 58 EP - 65 PB - Elsevier CY - Amsterdam ER -