TY - CHAP A1 - Zischank, Wolfgang J. A1 - Heidler, Fridolin A1 - Wiesinger, J. A1 - Stimper, K. A1 - Kern, Alexander A1 - Seevers, M. T1 - Magnetic Fields and Induced Voltages inside LPZ 1 Measured at a 1:6 Scale Model Building N2 - Laborexperimente zu Blitzschutzzonen in Stahlbetongebäuden anhand eines Modells im Maßstab 1:6 N2 - For the application of the concept of Lightning Protection Zones (LPZ), the knowledge of the magnetic fields and induced voltages inside a structure is necessary. Laboratory experiments have been conducted at a downscaled model of a building (scale factor 1:6) to determine these electromagnetic quantities in case of a direct strike to the structure. The model (3 m x 2 m x 2 m) represented a small industrial building using the reinforcement of the concrete as electromagnetic shield. The magnetic fields and magnetic field derivatives were measured at several location inside the scaled model. Further, the voltages induced on three typical cable routes inside the model was determined. The influence of the lightning current waveshape, point-of-strike, bonding of the cable routes, and bridging of an expansion joint in the middle of the building on these quantities was studied. KW - Blitzschlag KW - Elektromagnetischer Schutzschild KW - Stahlbeton KW - Maßstabsgetreues Modell KW - Lightning KW - electromagnetic shielding KW - reinforced concrete KW - scaled model Y1 - 2004 ER - TY - JOUR A1 - Zischank, Wolfgang J. A1 - Heidler, Fridolin A1 - Wiesinger, J. A1 - Metwally, I. A1 - Kern, Alexander A1 - Seevers, M. T1 - Laboratory simulation of direct lightning strokes to a modeled building : measurement of magnetic fields and included voltages JF - Journal of electrostatics. 60 (2004), H. 2 - 4 Y1 - 2004 SN - 0304-3886 N1 - ISSN der E-Ausg.: 0304-3886 SP - 223 EP - 232 ER - TY - JOUR A1 - Ziller, Claudia A1 - Döring, Bernd T1 - Doppelfassaden - vom Experimentalmodell zum Massanzug JF - TAB Technik am Bau Y1 - 2004 SN - 0341-2032 VL - Bd. 35 IS - H. 12 SP - 58 EP - 63 ER - TY - JOUR A1 - Ziemons, Karl A1 - Heinrichs, U. A1 - Streun, M. A1 - Pietrzyk, U. T1 - Validation of GEANT3 simulation studies with a dual-head PMT ClearPET™ prototype JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry. Y1 - 2004 SN - 1082-3654 SP - 3053 EP - 3056 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. T1 - The ClearPET TM LSO/LuYAP phoswich scanner: a high performance small animal PET system JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes. Y1 - 2004 SN - 1082-3654 SP - 1728 EP - 1732 ER - TY - JOUR A1 - Ziemons, Karl A1 - Achten, R. A1 - Auffray, E. A1 - Müller-Veggian, Mattea T1 - The ClearPET™ neuro scanner: a dedicated LSO/LuYAP phoswich small animal PET scanner JF - 2004 IEEE Nuclear Science Symposium conference record : Nuclear Science Symposium, Medical Imaging Conference ; 16 - 22 October 2004, Rome, Italy ; [including the Symposium on Nuclear Power System (SNPS), 14th Room Temperature Semiconductor X- and Gamma-Ray Detectors Workshop and special focus workshops] / NPSS, Nuclear & Plasma Sciences Society. Guest ed.: J. Anthony Seibert Y1 - 2004 SN - 1082-3654 N1 - Nuclear Science Symposium Conference Record, 2004 IEEE SP - 2430 EP - 2433 PB - IEEE Operations Center CY - Piscataway, NJ ER - TY - JOUR A1 - Zatko, B. A1 - Dubecký, F. A1 - Bohacek, P. A1 - Gombia, E. A1 - Frigeri, P. A1 - Mosca, R. A1 - Franchi, S. A1 - Huarn, J. A1 - Nescas, V. A1 - Sekacova, M. A1 - Förster, Arnold A1 - Kordos, P. T1 - On the spectrometric performance limit of radiation detectors based on semi-insulating GaAs JF - Nuclear instruments and methods in physics research, Section A. 531 (2004), H. 1-2 Y1 - 2004 SN - 0168-9002 SP - 111 EP - 120 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Yasuhito, U. A1 - Iwasaki, H. A1 - Näther, Niko A1 - Schöning, Michael Josef A1 - Koudelka-Hep, M. T1 - Applications of the light-addressable potentiometric sensor to microfluidic devices JF - Digest of technical papers : September 12 - 15, 2004, Rome, Italy, Pontificia Universitas Sancto Thoma Aquinate in Urbe / [conference chairperson: C. Di Natale]. Y1 - 2004 SN - 88-7621-282-5 N1 - Eurosensors ; (18, 2004, Roma) SP - 434 EP - 437 CY - Roma ER - TY - JOUR A1 - Yoshinobu, T. A1 - Ui, Y. A1 - Iwasaki, H. A1 - Näther, Niko A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - Potentiometric imaging in a microfluidic channel JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 998 EP - 999 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Schöning, Michael Josef A1 - Finger, F. A1 - Moritz, W. A1 - Iwasaki, H. T1 - Fabrication of thin-film LAPS with amorphous silicon JF - Sensors. 4 (2004), H. 10 Y1 - 2004 SN - 1424-8220 SP - 163 EP - 169 ER - TY - JOUR A1 - Wollert, Jörg A1 - Vedral, Andreas A1 - Grimm, A. A1 - Holtmann, M. T1 - Bluetooth-Sicherheit : wie viel Persönlichkeit gebe ich preis? JF - Elektronik : Fachmedium für industrielle Anwender und Entwickler ; Sonderh. Wireless : Fachmedium für Entwicklungen funkbasierter Systeme Y1 - 2004 SN - 0013-5658 SN - 1611-5120 N1 - Printausg. in der Bibliothek vorhanden: 63 ZS 030; 23 Z 263 VL - Bd. 53 IS - Sonderh. März SP - 30 EP - 35 ER - TY - CHAP A1 - Wollert, Jörg T1 - Sicherheit und Sicherheitslücken in kabellosen Automatisierungsnetzwerken : wieviel Sicherheit braucht ein Automatisierungsnetzwerk? T2 - Funkgestützte Kommunikation in der industriellen Automatisierungstechnik : Tagung Düsseldorf, 4. und 5. Mai 2004. (VDI-Berichte ; 1843) Y1 - 2004 SN - 3-18-091843-8 SP - 91 EP - 104 PB - VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Wollert, Jörg T1 - Bluetooth, WLAN and ZigBee für die Automatisierungstechnik JF - Etz : Elektrotechnik & Automation Y1 - 2004 SN - 0948-7387 N1 - Printausg. in der Bibliothek vorhanden: 23 Z 133; 63 ZS 035 VL - Bd. 125 IS - H. 6 SP - 10 EP - 18 ER - TY - JOUR A1 - Wollert, Jörg T1 - Bluetooth in der Automatisierung : kabelfrei in eine bessere Zukunft JF - Elektronik : Fachmedium für industrielle Anwender und Entwickler Y1 - 2004 SN - 0013-5658 N1 - Printausg. in der Bibliothek vorhanden: 23 Z 263; 63 ZS 030 VL - Bd. 53 IS - H. 14 SP - 42 EP - 46 ER - TY - CHAP A1 - Wollert, Jörg T1 - Sicherheit in kabellosen Netzwerken T2 - SPS/IPC/DRIVES 2004 : SPS/IPC/DRIVES, Elektrische Automatisierung - Systeme und Komponenten, Fachmesse & Kongress, 23. - 25. Nov. 2004, Nürnberg Y1 - 2004 SN - 3-7723-6709-7 SP - 335 EP - 341 PB - Poing CY - Franzis ER - TY - JOUR A1 - Wilke, Thomas T1 - Vergessene Planungen – Die Kapelle im Neuen Schloß in Stuttgart JF - Zeitschrift für württembergische Landesgeschichte (ZWLG) Y1 - 2004 SN - 0044-3786 VL - 63 SP - 169 EP - 201 ER - TY - GEN A1 - Weßling, Matthias T1 - Como ser um Líder de Sucesso: Conceito científico - Auto-Avaliação - Experiências T1 - How to be a successful leader: concept - self-assessment - experiences N2 - O conceito científico de Lideranca situaçional explica que um líder tem que ser uma pessoa de múltiplas Funções e Competências. Nas empresas alemaes tem muitos pessoas pensando ser líderes, mas no fundo eles são somente Administradores. a diferenca é o seguinte: alguem que é somente capaz de trabalhar com seu conhecimento e com seus ferramentas, já sabe muito, mas isso nao è suficiente para ter sucesso. Ele è de verdade somente um administrador. Pois para ser um Líder de verdade ele precisa além disso as competencias social e individual. N2 - Führungskräfte haben dann maximalen Führungserfolg, wenn sie in der Lage sind, nicht lediglich administrative Manager zu sein, sondern vielmehr Coaches ihrer Mitarbeiterinnen und Mitarbeiter, die sie dabei unterstützen, ihre Kompetenzen weiter zu entwickeln, wie die Konzepte der situativen Führung und der reifegradgerechten Führung zeigen. Perspektivisch ist in der Praxis eine deutliche Verlagerung des Aufmerksamkeitsfokus von einer schwerpunktmäßig transaktionalen Führung hin zu einer schwerpunktmäßig transformatorischen Führung erforderlich, um nachhaltig Führungserfolg zu sichern. Dies wird deutlich bestätigt durch positive empirische Befunde in der betrieblichen Führungspraxis. KW - Führung KW - Führungskraft KW - Führung KW - Führungskraft KW - Führungserfolg KW - Leader KW - Leadership KW - Success Y1 - 2004 ER - TY - GEN A1 - Weßling, Matthias T1 - Liderança e Motivação Organizacional: Conceitos, Auto-Avaliações, Experiências T1 - Organizational Leadership and motivation: concepts, self-assessments, experiences N2 - Pensando na motivação de uma perspectiva gerencial, é muito importante ter a seguinte visão: ninguem pode conseguir motivar outras pessoas, mas um lider pode influenciá-las a fazer as coisas com mais entusiasmo. Além disso, ele deve conhecer a sua personalidade mesmo. Ele precisa de reconhecimento dos pontos fortes e fracos proprios. Quem – por exemplo – é bem fechado, precisa desenvolver mais forca para motivar as outras pessoas. Quem – por outro exemplo – adora de fazer todas coisas sozinho, vai ter dificuldades com delegação para seus funcionarios. Se ele sabe desse ponto fraco proprio, ele pode evitar esse ponto fraco e delegar de verdade. Para conseguir essa meta, um dialogo de ´feedback´ com os funcionarios e muito importante para descobrir as diferenças entre a auto-percepção e o percepção dos outros, por exemplo sobre o estilo de liderança aplicada. N2 - Organisationale Führung und Motivation haben zu berücksichtigen, daß Motivation nicht geschaffen werden kann, sondern eine gute Führungskraft sich dadurch auszeichnet, daß sie in der Lage ist, die vorhandene Motivstruktur ihrer Mitarbeiterinnen und Mitarbeiter optimal zu adressieren, um einen maximalen Grad an Eigenmotivation zu erreichen. Hierzu ist es erforderlich, daß eine Führungskraft ihr eigenes Motivprofil ebenso kennt wie diejenigen ihrer Mitarbeiter. Darüber hinaus zeigen empirische Erfahrungen der Praxis immer wieder, daß die Differenz zwischen vermuteten und realen Motiven sehr groß ist, d. h. ein intensiver Dialog und eine lebendige Feedback-Kultur die kritischen Erfolgsfaktoren betrieblicher Führung sind. KW - Führung KW - Motivation KW - Organisationale Führung KW - Führung KW - Motivation KW - Leadership KW - Motivation Y1 - 2004 ER - TY - JOUR A1 - Weber, Hans-Joachim A1 - Mo, Xiumei T1 - Electrospinning P(LLA-CL) nanofiber: a tubular scaffold fabrication with circumferential alignment / Xiumei Mo, Hans-Joachim Weber JF - Contributions from 6th Austrian Polymer Meeting : Vienna, Austria, September 15 - 17, 2003 / Symposium ed.: W. H. Binder Y1 - 2004 N1 - Österreichische Polymertage <6, 2003, Wien>. - (Macromolecular symposia ; 217,1) SP - 413 EP - 416 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Weber, Hans-Joachim A1 - Hekmat, K. A1 - Zimmermann, T. A1 - Kampe, S. T1 - Impact of tranexamic acid vs. aprotinin on blood loss and transfusion requirements after cardiopulmonary bypass: a prospective, randomised, double-blind trial / Hekmat, K. ; Zimmermann, T. ; Kampe, S. ; Kasper, S. M. ; Weber, H. J. ; Geissler, H. J. ; Meh JF - Current Medical Research and Opinion. 20 (2004), H. 1 Y1 - 2004 SN - 0300-7995 SP - 121 EP - 126 ER -