TY - JOUR A1 - Förster, Arnold A1 - Verghese, S. A1 - Zamdmer, N. A1 - Hu, Qing T1 - An optical correlator using a low-temperature-grown GaAs photoconductor / S. Verghese ; N. Zamdmer ; Qing Hu .... A. Förster JF - Applied physics letters. 69 (1996), H. 6 Y1 - 1996 SN - 0003-6951 N1 - ISSN der E-Ausg.: 1077-3118 SP - 842 EP - 844 ER - TY - JOUR A1 - Cheenakula, Dheeraja A1 - Hoffstadt, Kevin A1 - Krafft, Simone A1 - Reinecke, Diana A1 - Klose, Holger A1 - Kuperjans, Isabel A1 - Grömping, Markus T1 - Anaerobic digestion of algal–bacterial biomass of an Algal Turf Scrubber system JF - Biomass Conversion and Biorefinery N2 - This study investigated the anaerobic digestion of an algal–bacterial biofilm grown in artificial wastewater in an Algal Turf Scrubber (ATS). The ATS system was located in a greenhouse (50°54′19ʺN, 6°24′55ʺE, Germany) and was exposed to seasonal conditions during the experiment period. The methane (CH4) potential of untreated algal–bacterial biofilm (UAB) and thermally pretreated biofilm (PAB) using different microbial inocula was determined by anaerobic batch fermentation. Methane productivity of UAB differed significantly between microbial inocula of digested wastepaper, a mixture of manure and maize silage, anaerobic sewage sludge, and percolated green waste. UAB using sewage sludge as inoculum showed the highest methane productivity. The share of methane in biogas was dependent on inoculum. Using PAB, a strong positive impact on methane productivity was identified for the digested wastepaper (116.4%) and a mixture of manure and maize silage (107.4%) inocula. By contrast, the methane yield was significantly reduced for the digested anaerobic sewage sludge (50.6%) and percolated green waste (43.5%) inocula. To further evaluate the potential of algal–bacterial biofilm for biogas production in wastewater treatment and biogas plants in a circular bioeconomy, scale-up calculations were conducted. It was found that a 0.116 km2 ATS would be required in an average municipal wastewater treatment plant which can be viewed as problematic in terms of space consumption. However, a substantial amount of energy surplus (4.7–12.5 MWh a−1) can be gained through the addition of algal–bacterial biomass to the anaerobic digester of a municipal wastewater treatment plant. Wastewater treatment and subsequent energy production through algae show dominancy over conventional technologies. KW - Biogas KW - Methane KW - Algal Turf Scrubber KW - Algal–bacterial bioflm KW - Circular bioeconomy Y1 - 2022 U6 - http://dx.doi.org/10.1007/s13399-022-03236-z SN - 2190-6823 N1 - Corresponding author: Dheeraja Cheenakula VL - 13 SP - 15 Seiten PB - Springer CY - Berlin ER - TY - JOUR A1 - Kuperjans, Isabel A1 - Starke, M. A1 - Esser, J. A1 - [u.a.], T1 - Analyse und Konzeption von Energieanlagen unter ökologischen, wirtschaftlichen und technischen Gesichtspunkten JF - WLB : Umwelttechnik für Industrie und Kommune Y1 - 2000 SN - 0341-2679 VL - 44 IS - 11/12 SP - 26 EP - 29 ER - TY - THES A1 - Borchert, Jörg T1 - Analyse von Determinanten der Großhandelspreise für Elektrizität anhand einer Systemstudie des deutschen Marktes Y1 - 2003 N1 - Berlin, Techn. Univ., Diss., 2003 ER - TY - CHAP A1 - Gedle, Yibekal A1 - Schmitz, Mark A1 - Gielen, Hans A1 - Schmitz, Pascal A1 - Herrmann, Ulf A1 - Teixeira Boura, Cristiano José A1 - Mahdi, Zahra A1 - Caminos, Ricardo Alexander Chico A1 - Dersch, Jürgen T1 - Analysis of an integrated CSP-PV hybrid power plant T2 - SolarPACES 2020 N2 - In the past, CSP and PV have been seen as competing technologies. Despite massive reductions in the electricity generation costs of CSP plants, PV power generation is - at least during sunshine hours - significantly cheaper. If electricity is required not only during the daytime, but around the clock, CSP with its inherent thermal energy storage gets an advantage in terms of LEC. There are a few examples of projects in which CSP plants and PV plants have been co-located, meaning that they feed into the same grid connection point and ideally optimize their operation strategy to yield an overall benefit. In the past eight years, TSK Flagsol has developed a plant concept, which merges both solar technologies into one highly Integrated CSP-PV-Hybrid (ICPH) power plant. Here, unlike in simply co-located concepts, as analyzed e.g. in [1] – [4], excess PV power that would have to be dumped is used in electric molten salt heaters to increase the storage temperature, improving storage and conversion efficiency. The authors demonstrate the electricity cost sensitivity to subsystem sizing for various market scenarios, and compare the resulting optimized ICPH plants with co-located hybrid plants. Independent of the three feed-in tariffs that have been assumed, the ICPH plant shows an electricity cost advantage of almost 20% while maintaining a high degree of flexibility in power dispatch as it is characteristic for CSP power plants. As all components of such an innovative concept are well proven, the system is ready for commercial market implementation. A first project is already contracted and in early engineering execution. KW - Hybrid energy system KW - Power plants KW - Electricity generation KW - Energy storage KW - Associated liquids Y1 - 2022 SN - 978-0-7354-4195-8 U6 - http://dx.doi.org/10.1063/5.0086236 SN - 1551-7616 (online) SN - 0094-243X (print) N1 - 26th International Conference on Concentrating Solar Power and Chemical Energy Systems 28 September–2 October 2020 Freiburg, Germany IS - 2445 / 1 PB - AIP conference proceedings / American Institute of Physics CY - Melville, NY ER - TY - JOUR A1 - Maurer, Florian A1 - Rieke, Christian A1 - Schemm, Ralf A1 - Stollenwerk, Dominik T1 - Analysis of an urban grid with high photovoltaic and e-mobility penetration JF - Energies N2 - This study analyses the expected utilization of an urban distribution grid under high penetration of photovoltaic and e-mobility with charging infrastructure on a residential level. The grid utilization and the corresponding power flow are evaluated, while varying the control strategies and photovoltaic installed capacity in different scenarios. Four scenarios are used to analyze the impact of e-mobility. The individual mobility demand is modelled based on the largest German studies on mobility “Mobilität in Deutschland”, which is carried out every 5 years. To estimate the ramp-up of photovoltaic generation, a potential analysis of the roof surfaces in the supply area is carried out via an evaluation of an open solar potential study. The photovoltaic feed-in time series is derived individually for each installed system in a resolution of 15 min. The residential consumption is estimated using historical smart meter data, which are collected in London between 2012 and 2014. For a realistic charging demand, each residential household decides daily on the state of charge if their vehicle requires to be charged. The resulting charging time series depends on the underlying behavior scenario. Market prices and mobility demand are therefore used as scenario input parameters for a utility function based on the current state of charge to model individual behavior. The aggregated electricity demand is the starting point of the power flow calculation. The evaluation is carried out for an urban region with approximately 3100 residents. The analysis shows that increased penetration of photovoltaics combined with a flexible and adaptive charging strategy can maximize PV usage and reduce the need for congestion-related intervention by the grid operator by reducing the amount of kWh charged from the grid by 30% which reduces the average price of a charged kWh by 35% to 14 ct/kWh from 21.8 ct/kWh without PV optimization. The resulting grid congestions are managed by implementing an intelligent price or control signal. The analysis took place using data from a real German grid with 10 subgrids. The entire software can be adapted for the analysis of different distribution grids and is publicly available as an open-source software library on GitHub. KW - distribution grid simulation KW - smart-charging KW - e-mobility Y1 - 2023 U6 - http://dx.doi.org/10.3390/en16083380 SN - 1996-1073 N1 - This article belongs to the Special Issue "Advanced Solutions for the Efficient Integration of Electric Vehicles in Electricity Grids" N1 - Corresponding author: Florian Maurer VL - 16 IS - 8 PB - MDPI CY - Basel ER - TY - CHAP A1 - Rosin, J. A1 - Mykoniou, K. A1 - Butenweg, Christoph T1 - Analysis Of Base Isolated Liquid Storage Tanks With 3D Fsi-Analysis As Well As Simplified Approaches T2 - 16th World Conference on Earthquake Engineering, 16WCEE 2017 Santiago Chile, January 9th to 13th 2017 N2 - Tanks are preferably designed, for cost-saving reasons, as circular, cylindrical, thin-walled shells. In case of seismic excitation, these constructions are highly vulnerable to stability failures. An earthquake-resistant design of rigidly supported tanks for high seismic loading demands, however, uneconomic wall thicknesses. A cost-effective alternative can be provided by base isolation systems. In this paper, a simplified seismic design procedure for base isolated tanks is introduced, by appropriately modifying the standard mechanical model for flexible, rigidly supported tanks. The non-linear behavior of conventional base isolation systems becomes an integral part of a proposed simplified process, which enables the assessment of the reduced hydrodynamic forces acting on the tank walls and the corresponding stress distribution. The impulsive and convective actions of the liquid are taken into account. The validity of this approach is evaluated by employing a non-linear fluid-structure interaction algorithm of finite element method. Special focus is placed on the boundary conditions imposed from the base isolation and the resulting hydrodynamic pressures. Both horizontal and vertical component of ground motion are considered in order to study the principal effects of the base isolation on the pressure distribution of the tank walls. The induced rocking effects associated with elastomeric bearings are discussed. The results manifest that base isolated tanks can be designed for seismic loads by means of the proposed procedure with sufficient accuracy, allowing to dispense with numerically expensive techniques. KW - liquid storage tank KW - seismic isolation KW - elastomeric bearing KW - friction pendulum bearing KW - simplified approach Y1 - 2017 N1 - Paper No 2246 SP - 1 EP - 14 PB - Chilean Association on Seismology and Earthquake Engineering (ACHISINA) ER - TY - JOUR A1 - Butenweg, Christoph A1 - Rosin, Julia A1 - Holler, Stefan T1 - Analysis of cylindrical granular material silos under seismic excitation JF - Buildings N2 - Silos generally work as storage structures between supply and demand for various goods, and their structural safety has long been of interest to the civil engineering profession. This is especially true for dynamically loaded silos, e.g., in case of seismic excitation. Particularly thin-walled cylindrical silos are highly vulnerable to seismic induced pressures, which can cause critical buckling phenomena of the silo shell. The analysis of silos can be carried out in two different ways. In the first, the seismic loading is modeled through statically equivalent loads acting on the shell. Alternatively, a time history analysis might be carried out, in which nonlinear phenomena due to the filling as well as the interaction between the shell and the granular material are taken into account. The paper presents a comparison of these approaches. The model used for the nonlinear time history analysis considers the granular material by means of the intergranular strain approach for hypoplasticity theory. The interaction effects between the granular material and the shell is represented by contact elements. Additionally, soil–structure interaction effects are taken into account. KW - granular silo KW - earthquake engineering KW - hypoplasticity KW - nonlinear transient analyses Y1 - 2017 U6 - http://dx.doi.org/10.3390/buildings7030061 SN - 2075-5309 VL - 7 IS - 3 SP - 1 EP - 12 PB - MDPI CY - Basel ER - TY - CHAP A1 - Breitbach, Gerd A1 - Alexopoulos, Spiros A1 - May, Martin A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Analysis of volumetric solar radiation absorbers made of wire meshes T2 - AIP Conference Proceedings Y1 - 2019 U6 - http://dx.doi.org/10.1063/1.5117521 SN - 0094243X VL - 2126 SP - 030009-1 EP - 030009-6 ER - TY - JOUR A1 - Barsov, S. A1 - Bechstedt, U. A1 - Hardt, Arno T1 - ANKE, a new facility for medium energy hadron physics at COSY-Jülich / S. Barsov [u.a.] JF - Nuclear instruments and methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. Vol. 462, iss. 3 Y1 - 2001 SN - 0167-5087 (Print) ; 0168-9002 (E-journal) SP - 364 EP - 381 ER - TY - JOUR A1 - Kern, Alexander A1 - Zischank, Wolfgang A1 - Beierl, Ottmar T1 - Anmerkungen zur Berechnung des Trennungsabstands nach DIN EN 62305-3 (VDE 0185-305-3): 2006-10 / Zischank, Wolfgang ; Beierl, Ottmar ; Kern, Alexander JF - 7. VDE-ABB-Blitzschutztagung : Vorträge der VDE-ABB-Fachtagung vom 15. bis 16. November 2007 in Neu-Ulm / Veranst.: Ausschuss für Blitzschutz und Blitzforschung (ABB) im VDE, Verband der Elektrotechnik, Elektronik, Informationstechnik e.V. Wiss. Tagungsltg.: K. Stimper Y1 - 2007 SN - 978-3-8007-3062-9 N1 - VDE-Fachbericht ; 64 ; Blitzschutztagung <7, 2007, Neu-Ulm> SP - 1 EP - 8 PB - VDE-Verl. CY - Berlin ER - TY - JOUR A1 - Förster, Arnold A1 - Darmo, J. A1 - Dubecký, F. A1 - Kordos, P. T1 - Annealing characteristics of native defects in low-temperature-grown MBE GaAs / J. Darmo ; F. Dubecky ; P. Kordos ; A. Förster JF - Semiconducting and insulating materials 1996 : proceedings of the 9th Conference on Semiconducting and Insulating Materials (SIMC '9), April 29 - May 3, 1996, Toulouse, France / [IEEE] Y1 - 1996 SN - 0-7803-3095-1 N1 - 2. ISBN: 0-7803-3179-6 ; Conference on Semiconducting and Insulating Materials <9, 1996, Toulouse> ; Institute of Electrical and Electronics Engineers ; IEEE Cat. No.96CH35881 SP - 67 EP - ff. CY - Piscataway, NJ [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Darmo, J. A1 - Dubecky, F. A1 - Kordos, P. T1 - Annealing effect on concentration of EL6-like deep-level state in low-temperature-grown molecular beam epitaxial GaAs. Darmo, J.; Dubecky, F.; Kordos, P.; Förster, A. JF - Applied Physics Letters. 72 (1998), H. 5 Y1 - 1998 SN - 1077-3118 SP - 590 EP - 592 ER - TY - BOOK A1 - Breitbach, Gerd A1 - Altes, Jürgen T1 - Anwendung der Finite Elemente Methode auf Probleme mit Wärmestrahlungsaustausch Y1 - 1985 N1 - (Berichte der Kernforschungsanlage Jülich / Kernforschungsanlage ; 2013) PB - Zentralbibliothek der Kernforschungsanlage CY - Jülich ER - TY - JOUR A1 - Breitbach, Gerd A1 - Altes, J. A1 - Szimmat, J. T1 - Anwendung der Finite-Element-Methode bei der Berechnung des Wärmetransports durch Strahlung / J. Altes ; G. Breitbach ; J. Szimmat JF - International FEM-Congress : Baden-Baden, Federal Republic of Germany, 17./18. November 1986 Y1 - 1989 N1 - International FEM Congress <15, 1986, Baden-Baden> SP - 127 EP - 148 PB - IKO Software Service GmbH CY - Stuttgart ER - TY - BOOK A1 - Förster, Arnold T1 - Anwendung der hochauflösenden Elektronenenergieverlustspektroskopie zum Studium von Halbleiterschichtsystemen. - (Berichte der Kernforschungsanlage Jülich / Kernforschungsanlage ; 2247) Y1 - 1988 N1 - Zugl.: Aachen, Techn. Hochsch., Diss., 1988 PB - Zentralbibliothek der Kernforschungsanlage CY - Jülich ER - TY - JOUR A1 - Schwarzer, Klemens T1 - Anwendung solarer Hochtemperaturwärme am Beispiel eines Solarkochers JF - Wege in die Solargesellschaft 4 : Dokumentation zur Vortragsreihe an der Fachhochschule Darmstadt in Zusammenarbeit mit dem IKU-Institut für kommunale Wirtschaft und Umweltplanung im Sommersemester 1993 / [Hrsg.: Projektgruppe Solarenergie an der Fachhochschule Darmstadt ; IKU-Inst. für Kommunale Wirtschaft u. Umweltplanung. Red.: Helmut C. Büscher] Y1 - 1993 N1 - Ringvorlesung Wege in die Solargesellschaft <4, 1993, Darmstadt> SP - 13 EP - 24 PB - FHD CY - Darmstadt ER - TY - BOOK A1 - Dören, Horst-Peter T1 - Anwendung von AlN- bzw. AlN-Al2O3-Mischungen als Festelektrolyt in Eisenschmelzen bei 1640° C Y1 - 1977 N1 - Dissertation, RWTH Aachen CY - Aachen ER - TY - CHAP A1 - Kruska, Martin A1 - Kuperjans, Isabel T1 - Análisis Thermodinámicos : [Capítulo 3.3] T2 - Uso racional de energía : eficiencia energética y energías renovables. - (Manual para consultores y expertos) Y1 - 1999 SP - 3.3-1 EP - 3.3-15 PB - Ministerio de Energía y Minas CY - Lima ER - TY - JOUR A1 - Helsper, Christoph A1 - Nießner, R. T1 - Application of a Multistep Condensation Nuclei Counter as a Detector for Particle Surface Composition / Nießner, R. ; Helsper, C. JF - Journal of Aerosol Science. 16 (1985), H. 3 Y1 - 1985 SN - 0021-8502 SP - 201 EP - 209 ER -