TY - CHAP A1 - Kalker, Ines A1 - Toll, B. A1 - Holler, Stefan A1 - Butenweg, Christoph A1 - Topping, B. H. V. A1 - Mota Soares, C. A. T1 - Capacity analysis of textile retrofitted unreinforced masonry T2 - Proceedings of the Seventh International Conference on Computational Structures Technology : [Lisbon, Portugal, 7 - 9 September 2004] / ed. by B. H. V. Topping ... Y1 - 2004 SN - 0-948749-95-4 U6 - https://doi.org/10.4203/ccp.79.194 SP - 431 EP - 432 PB - Civil-Comp Press CY - Stirling ER - TY - CHAP A1 - Kern, Alexander A1 - Beierl, Ottmar A1 - Zischank, Wolfgang T1 - Calculation of the separation distance according to IEC 62305-3: 2006-10 - Remarks for the application and simplified methods N2 - [Paper of the X International Symposium on Lightning Protection 9th - 13th November, 2009 - Curitiba, Brazil. 6 pages] The international standard IEC 62305-3, published in 2006, requires as an integral part of the lightning protection system (LPS) the consideration of a separation distance between the conductors of the LPS and metal and electrical installations inside the structure to be protected. IEC 62305-3 gives two different methods for this calculation: a standard, simplified approach and a more detailed approach, which differ especially regarding the treatment of the current sharing effect on the LPS conductors. Hence, different results for the separation distance are possible, leading to some discrepancies in the use of the standard. The standard approach defined in the main part (Clause 6.3) and in Annex C of the standard in some cases may lead to a severe oversizing of the required separation distance. The detailed approach described in Annex E naturally gives more correct results. However, a calculation of the current sharing amongst all parts of the air-termination and downconductor network is necessary, in many cases requiring the use of network analysis programs. In this paper simplified methods for the assessment of the current sharing are presented, which are easy to use as well as sufficiently adequate. KW - Blitzschutz KW - Lightning protection Y1 - 2009 N1 - Paper in: [10. International Symposium on Lightning Protection 9. 13. November 2009, Curitiba, Brasilien. 6 Seiten] ER - TY - CHAP A1 - Wahle, Michael T1 - Calculation of the response of heat exchanger tubes with regard to nonlinear and prestressing effects T2 - Vibration in nuclear plant : proceedings of the 3rd International Conference on Vibration in Nuclear Plant held on 11 - 14 May 1982, Keswick ; vol. 1 Y1 - 1983 SN - 0-7277-0192-4 (Druckausg.) SN - 978-0-7277-5270-3 (E-Book) N1 - International Conference on Vibration in Nuclear Plant <3, 1982, Keswick> N1 - Paper 1.10 (Log No. 71) SP - 162 EP - 183 PB - British Nuclear Energy Society CY - London ER - TY - CHAP A1 - Pfundt, H. A1 - Vogelsang, D. A1 - Gerling, Ulrich T1 - Calculation of the crust profile in aluminium reduction cells by thermal computer modelling T2 - Light metals 1989 : 118th annual meeting of the Minerals, Metals and Materials Society, Las Vegas, NV, Feb. 27 - Mar. 03. 1989 Y1 - 1988 SP - 371 EP - 377 PB - Minerals, Metals and Materials Soc. CY - Warrendale, Pa. ER - TY - CHAP A1 - Birgel, Stefan A1 - Leschinger, Tim A1 - Wegmann, Kilian A1 - Staat, Manfred ED - Erni, Daniel ED - Fischerauer, Alice ED - Himmel, Jörg ED - Seeger, Thomas ED - Thelen, Klaus T1 - Calculation of muscle forces and joint reaction loads in shoulder area via an OpenSim based computer calculation T2 - 2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West Y1 - 2017 SN - 978-3-9814801-9-1 U6 - https://doi.org/10.17185/duepublico/43984 N1 - A young researchers track of the 7th IEEE Workshop & SENSORICA 2017 N1 - In der Druckausgabe des Abstractbandes ist dieser Beitrag lose als Erratum beigefügt. SP - 116 EP - 117 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Tran, Thanh Ngoc A1 - Staat, Manfred A1 - Kreißig, R. T1 - Calculation of load carrying capacity of shell structures with elasto-plastic material by direct methods N2 - Proceedings of the International Conference on Material Theory and Nonlinear Dynamics. MatDyn. Hanoi, Vietnam, Sept. 24-26, 2007, 8 p. In this paper, a method is introduced to determine the limit load of general shells using the finite element method. The method is based on an upper bound limit and shakedown analysis with elastic-perfectly plastic material model. A non-linear constrained optimisation problem is solved by using Newton’s method in conjunction with a penalty method and the Lagrangean dual method. Numerical investigation of a pipe bend subjected to bending moments proves the effectiveness of the algorithm. KW - Finite-Elemente-Methode Y1 - 2007 ER - TY - CHAP A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Calculation of interception efficiencies for mesh-type air-terminations according to IEC 62305-3 using a dynamic electro-geometrical model T2 - International Conference on Lightning Protection (ICLP) : 2 - 7 Sept. 2012, Vienna Y1 - 2012 SN - 978-1-4673-1896-9 (E-Book) ; 978-1-4673-1898-3 (Print) SP - 1 EP - 6 PB - IEEE CY - Piscataway, NJ ER - TY - CHAP A1 - Christen, Marc A1 - Bartelt, Perry A1 - Kowalski, Julia A1 - Stoffel, Lukus T1 - Calculation of dense snow avalanches in three-dimensional terrain with the numerical simulation programm RAMMS T2 - Proceedings ISSW 2008 ; International Snow Science Workshop. Whistler 2008 N2 - Numerical models have become an essential part of snow avalanche engineering. Recent advances in understanding the rheology of flowing snow and the mechanics of entrainment and deposition have made numerical models more reliable. Coupled with field observations and historical records, they are especially helpful in understanding avalanche flow in complex terrain. However, the application of numerical models poses several new challenges to avalanche engineers. A detailed understanding of the avalanche phenomena is required to specify initial conditions (release zone dimensions and snowcover entrainment rates) as well as the friction parameters, which are no longer based on empirical back-calculations, rather terrain roughness, vegetation and snow properties. In this paper we discuss these problems by presenting the computer model RAMMS, which was specially designed by the SLF as a practical tool for avalanche engineers. RAMMS solves the depth-averaged equations governing avalanche flow with first and second-order numerical solution schemes. A tremendous effort has been invested in the implementation of advanced input and output features. Simulation results are therefore clearly and easily visualized to simplify their interpretation. More importantly, RAMMS has been applied to a series of well-documented avalanches to gauge model performance. In this paper we present the governing differential equations, highlight some of the input and output features of RAMMS and then discuss the simulation of the Gatschiefer avalanche that occurred in April 2008, near Klosters/Monbiel, Switzerland. KW - snow KW - avalanche Y1 - 2008 SP - 709 EP - 716 ER - TY - CHAP A1 - Gorzalka, Philip A1 - Dahlke, Dennis A1 - Göttsche, Joachim A1 - Israel, Martin A1 - Patel, Dhruvkumar A1 - Prahl, Christoph A1 - Schmiedt, Jacob Estevam A1 - Frommholz, Dirk A1 - Hoffschmidt, Bernhard A1 - Linkiewicz, Magdalena T1 - Building Tomograph–From Remote Sensing Data of Existing Buildings to Building Energy Simulation Input T2 - EBC, Annex 71, Fifth expert meeting, October 17-19, 2018, Innsbruck, Austria Y1 - 2018 ER - TY - CHAP A1 - Siegert, Petra A1 - Iding, Hans A1 - Baumann, Martin A1 - McLeish, Michael J. A1 - Kenyon, George L. A1 - Pohl, Martina T1 - Broadening of the substrate spectra of two ThDP-dependent decarboxylases using site-directed-mutagenesis T2 - Proceedings of the 4th International Congress on Biochemical Engineering : 17 and 18 February 2000, Stuttgart Y1 - 2000 SN - 3-8167-5570-4 SP - 38 EP - 42 ER - TY - CHAP A1 - Sajatovic, Miodrag A1 - Rihacek, Christoph A1 - Haindl, Bernhard A1 - Schnell, Michael A1 - Brandes, Sinja A1 - Gligorevic, Snjezana T1 - Broadband VHF (B-VHF) project achievements and follow-on activities T2 - Integrated Communications, Navigation and Surveillance Conference : Herndon, VA, 1 - 3 May 2007 Y1 - 2007 SN - 1-4244-1216-1 SP - 1 EP - 8 ER - TY - CHAP A1 - Uibel, Thomas T1 - Brettsperrholz – Verbindungen mit mechanischen Verbindungsmitteln T2 - Ingenieurholzbau, Karlsruher Tage 2007 : Forschung für die Praxis; 4. und 5. Oktober 2007; Tagungsband / Universität Karlsruhe (TH), Lehrstuhl für Ingenieurholzbau und Baukonstruktionen Y1 - 2007 SP - 62 EP - 73 PB - Bruder-Verlag CY - Köln ER - TY - CHAP A1 - Steuer-Dankert, Linda A1 - Berg, Tobias A1 - Leicht-Scholten, Carmen T1 - Breaking the habit – new approaches in engineering education T2 - Proceedings of the 43rd Annual Conference of the European Society for Engineering Education N2 - Within the framework of the project a genderand diversity-oriented teaching evaluation and modern, media-supported blended learning approaches were used in order to achieve the intended goals. First research results of the literature and status quo analysis were already implemented and tested in newly designed teaching approaches, for example in a multidisciplinary introductory lecture of civil engineering at RWTH Aachen University. KW - teaching KW - engineering education KW - gender and diversity KW - best practice Y1 - 2015 SN - 978-2-87352-012-0 N1 - Annual Conference of the European Society for Engineering Education , Orléans , France , SEFI , 2015-06-29 - 2015-07-02 ER - TY - CHAP A1 - Edip, Kemal A1 - Garevski, Mihail A1 - Butenweg, Christoph A1 - Sesov, Vlatko A1 - Bojadjieva, Julijana A1 - Gjorgjiev, Igor T1 - Boundary effects on seismic analysis of multi-storey frames considering soil structure interaction phenomenon T2 - Seismic design of industrial facilities : proceedings of the International Conference on Seismic Design of Industrial Facilities (SeDIF-Conference) ; [Aachen, 26. - 27. September 2013] / Chair of Structural Statics and Dynamics, RWTH Aachen. Sven Klinkel ..., ed Y1 - 2014 SN - 978-3-658-02809-1 (Print) ; 978-3-658-02810-7 U6 - https://doi.org/10.1007/978-3-658-02810-7_47 SP - 569 EP - 576 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Bung, Daniel Bernhard A1 - Hildebrandt, Arndt A1 - Oertel, Mario A1 - Schlenkhoff, Andreas A1 - Schlurmann, Torsten ED - McKee Smith, Jane T1 - Bore propagation over a submerged horizontal plate by physical and numerical simulation T2 - Coastal engineering 2008 : proceedings of the 31st international conference; Hamburg, Germany, 31 August - 5 September 2008 ; Vol. 4 Y1 - 2008 SN - 9814277401 ; 9789814277402 SP - 3542 EP - 3553 ER - TY - CHAP A1 - Wollert, Jörg T1 - Bluetooth in Embedded-Anwendungen in der Automatisierungstechnik T2 - Tagungsband / SPS IPC Drives 2002 : 13. Fachmesse und Kongress, 26. - 28. November 2002 Nürnberg; elektrische Automatisierung - Systeme und Komponenten. (Praxiswissen IEE - Automatisierung) Y1 - 2002 SN - 3-7785-2863-7 SP - 28 EP - 37 PB - Hüthig CY - Heidelberg ER - TY - CHAP A1 - Wollert, Jörg A1 - Vedral, Andreas T1 - Bluetooth - Integrationstechnologie für automotive Anwendungen T2 - Begleittexte zum Entwicklerforum ZigBee & Co. - Drahtlose Nahbereichsnetzwerke : 20. April 2005, München-Dornach Y1 - 2005 ER - TY - CHAP A1 - Oertel, Mario A1 - Bung, Daniel Bernhard A1 - Schlenkhoff, Andreas ED - Carstensen, Dirk T1 - Blocksteinrampen in Riegelbauweise : Neue Bemessungsansätze T2 - Staubauwerke : planen, bauen, betreiben; 35. Dresdner Wasserbaukolloquium 2012, 08. - 09. März 2012 Y1 - 2012 SN - 978-3-86780-261-1 SP - 317 EP - 326 PB - Selbstverl. der Techn. Univ. CY - Dresden ER - TY - CHAP A1 - Krichel, Frank A1 - Kern, Alexander A1 - Krämer, Heinz-Josef A1 - Wettingfeld, Jürgen A1 - Reetz, Josef A1 - Kienlein, Manfred T1 - Blitzschutzmaßnahmen für Photovoltaik- und kleine Windenergieanlagen – Einige Beispiele T1 - Lightning Protection for photovoltaic and small wind energy power plants N2 - Ein von der Arbeitsgemeinschaft (AG) Solar NRW und diversen Industriepartnern gefördertes und an der Fachhochschule Aachen, Abt. Jülich durchgeführtes Forschungsprojekt „Blitzschutz für netz-autarke Hybridanlagen“ machte es möglich, sich mit dem Blitzschutz speziell solcher Anlagen näher zu beschäftigen. Vermehrt bekannt gewordene Schadensfälle an nicht netz-gekoppelten Hybridanlagen waren der Auslöser, den Schutz zu überdenken. Definiertes Ziel war es, für netz-autarke energietechnische Anlagen ein Konzept zum Schutz vor Blitzeinwirkungen zu erstellen. Diese Anlagen bestehen üblicherweise aus einer oder mehreren Photovoltaikanlagen, ggf. auch Solarthermieanlagen und einem oder mehreren kleineren Windgeneratoren (sie werden deshalb auch als Hybridanlagen bezeichnet). Zur Erhöhung der Versorgungssicherheit kann noch ein Dieselaggregat dazukommen. Hybridanlagen werden vor allem in Gebieten mit sehr schlechter öffentlicher Energieversorgung eingesetzt, d.h. insbesondere in relativ dünn bewohnten Gebieten und in Entwicklungsländern. Dem Blitzschutz von Hybridanlagen kommt dabei eine steigende Bedeutung zu. Besonderes Augenmerk in dem genannten Forschungsprojekt sollte dabei auf die technisch/wirtschaftliche Ausgewogenheit des Schutzes gelegt werden: • die Schutzmaßnahmen sollen nur in solchen Fällen eingesetzt werden, wo dies als Ergebnis von Risikoanalysen sinnvoll erscheint; • für typische netz-autarke Hybridanlagen sollen die Schutzmaßnahmen ohne deutliche Verteuerung realisierbar sein (es soll also kein absoluter Schutz realisiert werden; ggf. soll lediglich der auftretende Schaden soweit möglich minimiert werden). Dazu wurde in einem ersten Schritt zunächst eine Aufnahme des Iststandes einiger typischer netz-autarker Hybridanlagen und deren einzelnen Komponenten durchgeführt. Aufgrund dessen wurde eine umfassende Risikoanalyse zur Blitzbedrohung dieser Anlagen auf der Basis von VDE V 0185 Teil 2:2002-11 [1] erstellt. Die Ergebnisse mündeten in ein technisch/wirtschaftlich ausgewogenes Konzept für den Anlagen- Blitzschutz (d.h. insbesondere dem Schutz vor direkten Blitzeinschlägen und deren unmittelbaren Auswirkungen) nach VDE V 0185 Teil 3:2002-11 [2] und für den Elektronik-Blitzschutz (d.h. für den Schutz vor Überspannungen durch direkte, insbesondere aber auch indirekte Blitzeinschläge) nach VDE V 0185 Teil 4:2002-11 [3]. Aufgrund der gesammelten Ergebnisse konnten dabei allgemeine Empfehlungen für den Äußeren und Inneren Blitzschutz von regenerativen Energieerzeugungssystemen erstellt werden. Diese sollen in Schulungen einmünden, die für Hersteller und Betreiber von Hybridanlagen angeboten werden. Durch die Anwendung wird der Schutz der Anlagen vor Blitzeinwirkung und elektromagnetischen Störungen verbessert, was sich in einer reduzierten Ausfallwahrscheinlichkeit bzw. erhöhten Verfügbarkeit wiederspiegelt. An einigen ausgewählten Anlagen werden mit Hilfe der im Projekt involvierten Industriepartner die Schutzmaßnahmen realisiert. Hierbei entstanden den Eigentümern bzw. Betreibern der Anlagen keine Kosten. In diesem Beitrag werden beispielhaft drei Anlagenprojekte detailliert gezeigt. Es handelt sich dabei um eine Schweinezuchtfarm in Magallón (Spanien, Zaragozza), das bioklimatische Haus (Kreta, Heraklion) und die Tegernseer- Hütte (Deutschland, Lenggries). KW - Blitzschutz KW - Photovoltaikanlagen KW - Windenergieanlagen KW - Lightning protection KW - photovoltaic system KW - wind turbine Y1 - 2003 ER - TY - CHAP A1 - Kern, Alexander A1 - Neskakis, Apostolos A1 - Müller, Klaus-Peter T1 - Blitzschutzkonzept für eine netz-autarke Hybridanlage am Beispiel der Anlage VATALI auf Kreta N2 - Netz-autarke Anlagen bestehen üblicherweise aus einer oder mehreren Photovoltaik- (PV-) Anlagen, ggf. auch Solarthermie- (ST-) Anlagen und einem oder mehreren kleineren Windgeneratoren (sie werden deshalb auch als Hybridanlagen bezeichnet) und werden vor allem in Gegenden mit sehr schlechter öffentlicher Energieversorgung eingesetzt, d.h. insbesondere in rel. dünn bewohnten Gebieten und in Entwicklungsländern. Der Blitzschutz von netz-autarken Hybridanlagen ist ein bislang noch vergleichsweise unzureichend bearbeitetes Fachgebiet. Für große Windenergie-Anlagen (WEA) wurde in den letzten Jahren eine Zahl von FuE-Projekten durchgeführt, zum Großteil finanziert durch die öffentliche Hand, zum kleineren Teil auch durch die Industrie, d.h. die WEAHersteller. Dabei wurden bestehende Defizite im Design der WEA festgestellt und Maßnahmen vorgeschlagen, die vor den mechanischen Zerstörungen insbesondere des Rotors und vor den Störungen und Zerstörungen an den elektrischen / elektronischen Systemen der WEA weitgehend Schutz bieten [1, 2, 3]. Der Stand-der- Normung ist im Entwurf DIN VDE 0127 Teil 24 „Blitzschutz für Windenergieanlagen“ (dt. Übersetzung des internationalen Drafts IEC 61400-24 „Wind turbine generator systems; Part 24: Lightning Protection“) dokumentiert [4]. Die Maßnahmen sind allerdings insbesondere für größere WEA vorgesehen; im Falle kleinerer WEA lassen sie sich nur bedingt umsetzen. Trotzdem sind auch kleinere WEA rel. stark blitzeinschlaggefährdet, wenn sie auf einer Bergkuppe o.ä. platziert werden. Für solche kleinere WEA, wie sie bei Hybridanlagen üblicherweise Verwendung finden, müssen die Blitzschutzmaßnahmen aus der DIN VDE 0127 Teil 24 angepasst werden. Für PV- und ST-Anlagen ist eine entsprechende Blitzschutz-Norm noch nicht in Sicht. Hier ist vor allem der Schutz gegen direkte Blitzeinschläge in die Anlage bzw. die Gebäude noch nicht ausreichend beachtet. Blitzfangeinrichtungen sind oft nicht vorgesehen. In aller Regel hat man dabei bisher eine Ausführungsform des Blitzschutzes realisiert, die primär einen Ferneinschlag berücksichtigt und die dabei entstehenden induzierten, rel. energieschwachen Überspannungen durch schwächere Schutzelemente wie Rückstromdioden, Bypassdioden und zum Teil thermisch überwachte Varistoren begrenzt [5, 6, 7]. Diese Schutzelemente können allerdings bei Naheinschlägen bzw. Direkteinschlägen überlastet und damit zerstört werden. Darüber hinaus können Nahoder Direkteinschläge auch zur Schwächung der elektrischen Festigkeit der PVModulisolierung führen. Die Folge davon sind lokale extreme Wärmeentwicklungen, die sogar ein Schmelzen von Glas (sekundärer Langzeiteffekt) hervorrufen könnten. Bei einem Blitzeinschlag in die netz-autarke Hybridanlage VATALI auf Kreta im Jahre 2000 wurden sowohl einige mechanische wie auch elektrische Komponenten der Anlage zerstört bzw. zum Teil schwer beschädigt. Die Anlage VATALI besaß zum Zeitpunkt des Blitzeinschlags keinen wirksamen Blitzschutz. Der Gesamtschaden der Hardware belief sich auf ca. 60.000,- EURO. Die exponierte Stellung der Anlage auf einer Bergspitze stellte und stellt nach wie vor ein enormes Blitzeinschlag-Risiko dar, so dass auch zukünftig mit Blitzeinwirkungen gerechnet werden muss. Die Anlage wurde inspiziert, blitzschutz-technische Erfordernisse definiert und daraus Ertüchtigungsmaßnahmen abgeleitet, die mit überschaubarem Aufwand realisierbar sind. KW - Blitzschutz KW - Hybridanlage KW - Regenerative Energieanlagen KW - Lightning protection KW - renewable energy KW - hybrid system Y1 - 2001 ER -