TY - CHAP A1 - Kowalski, Julia T1 - Numerical Debris Flow Simulation T2 - Schweizer Numerik Kolloquium : Book of Abstracts 12. April 2006 Y1 - 2006 ER - TY - JOUR A1 - Grajewski, Matthias A1 - Hron, Jaroslav A1 - Turek, Stefan T1 - Numerical analysis for a new non-conforming linear finite element on quadrilaterals JF - Journal of Computational and Applied Mathematics Y1 - 2006 U6 - http://dx.doi.org/10.1016/j.cam.2005.05.024 SN - 0377-0427 VL - 193 IS - 1 SP - 38 EP - 50 ER - TY - JOUR A1 - Stanley, Lesley A. A1 - Horsburgh, Brian C. A1 - Ross, Jillian A1 - Scheer, Nico A1 - Wolf, C. Roland T1 - Nuclear Receptors which play a pivotal role in drug disposition and chemical toxicity JF - Drug Metabolism Reviews Y1 - 2006 U6 - http://dx.doi.org/10.1080/03602530600786232 SN - 1097-9883 VL - 38 IS - 3 SP - 515 EP - 597 ER - TY - JOUR A1 - Heuermann, Holger A1 - Erkens, H. T1 - Novel RF switch concepts for differential wireless communications frontends. Erkens, H.; Heuermann, H. JF - IEEE Transactions on Microwave Theory and Techniques. 54 (2006), H. 6, Part 1 Y1 - 2006 SN - 0018-9480 SP - 2376 EP - 2382 ER - TY - CHAP A1 - Arida, Hassan A. A1 - Kloock, Joachim P. A1 - Schöning, Michael Josef T1 - Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations N2 - A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors. KW - Biosensor KW - Heavy metal detection KW - thin-film microsensors KW - organic PVC membranes Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1545 ER - TY - JOUR A1 - Braband, Henrik A1 - Paulßen, Elisabeth A1 - Abram, Ulrich T1 - Nitridorhenium(V) Complexes with 1,3-Dialkyl-4,5-dimethylimidazole-2-ylidenes JF - Zeitschrift für anorganische und allgemeine Chemie : ZAAC = Journal of inorganic and general chemistry Y1 - 2006 U6 - http://dx.doi.org/10.1002/zaac.200600002 SN - 1521-3749 VL - 632 IS - 6 SP - 1051 EP - 1056 ER - TY - JOUR A1 - Elbers, Gereon A1 - Gäb, Martina A1 - Hoffmann, Katharina A1 - Lobe, Melanie T1 - NIR-spectroscopic investigation of foliage of ozone-stressed Fagus sylvatica trees / Gäb, Martina ; Hoffmann, Katharina ; Lobe, Melanie ; Metzger, Rut ; Ooyen, Sven van ; Elbers, Gereon ; Köllner, Barbara JF - Journal of Forest Research. 11 (2006), H. 2 Y1 - 2006 SN - 1341-6979 SP - 69 EP - 75 ER - TY - JOUR A1 - Grotendorst, Johannes A1 - Scott, Tony C. A1 - Aubert-Frécon, Monique T1 - New Approach for the Electronic Energies of the Hydrogen Molecular Ion / Scott, Tony C. ; Aubert-Frécon, Monique ; Grotendorst, Johannes JF - Chemical Physics. 324 (2006), H. 2/3 Y1 - 2006 SN - 0301-0104 SP - 323 EP - 338 ER - TY - JOUR A1 - Hartung, Frank A1 - Schieder, Andreas A1 - Kampmann, Markus A1 - Vorwerk, Marc T1 - Network Supported Media Delivery in Ambient Networks (Netzwerkunterstützte Medienverteilung) / Schieder, Andreas ; Kampmann, Markus ; Hartung, Frank ; Vorwerk, Marc ; Rembarz, René JF - it - Information Technology . 48 (2006), H. 5 Y1 - 2006 SN - 1611-2776 N1 - in der Bereichsbibliothek Eupener Str. unter der Signatur 23 Z 376 vorhanden SP - 264 EP - 273 ER - TY - JOUR A1 - Heuermann, Holger T1 - Multiport S-parameter calculation from two-port network analyzer measurements with or without switch matrix JF - ARFTG Conference, 2006 67th, San Francisco, CA Y1 - 2006 SN - 978-0-7803-9529-9 SP - 219 EP - 222 ER - TY - JOUR A1 - Dachwald, Bernd A1 - Seboldt, W. A1 - Richter, L. T1 - Multiple rendezvous and sample return missions to near-Earth objects using solar sailcraft / Dachwald, B. ; Seboldt, W. ; Richter, L. JF - Acta Astronautica. 59 (2006), H. 8-11 Y1 - 2006 SN - 0094-5765 N1 - International Conference on Low Cost Planetary Missions <5, 2003, Noordwijk> ; Selected Proceedings SP - 768 EP - 776 ER - TY - CHAP A1 - Pfaff, Raphael A1 - Vinsonneau, B. A1 - Burnham, K. J. T1 - Multiple models for nonlinear systems T2 - Proceedings / Eigteenth International Conference on Systems Engineering : ICSE 2006 : 5 - 7 September 2006 ; [held at Coventry University, UK] Y1 - 2006 SN - 1-84600-013-0 SP - 347 EP - 352 ER - TY - CHAP A1 - Näther, Niko A1 - Poghossian, Arshak A1 - Platen, J. A1 - Yoshinobu, T. A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - Multi-parameter sensing of both physical and (bio-)chemical quantities using the same transducer principle T2 - Biochemical sensing utilisation of micro- and nanotechnologies : Warsaw, [23rd - 26th] November 2005 / ed. by M. Mascini ... Y1 - 2006 SP - 172 EP - 181 CY - Warsaw ER - TY - CHAP A1 - Bukhari, Syed Faisal Ahmed A1 - Yang, Wuqiang T1 - Multi-interface level sensors and new development in monitoring and control of oil separators N2 - In the oil industry, huge saving may be made if suitable multi-interface level measurement systems are employed for effectively monitoring crude oil separators and efficient control of their operation. A number of techniques, e.g. externally mounted displacers, differential pressure transmitters and capacitance rod devices, have been developed to measure the separation process with gas, oil, water and other components. Because of the unavailability of suitable multi-interface level measurement systems, oil separators are currently operated by the trial-and-error approach. In this paper some conventional techniques, which have been used for level measurement in industry, and new development are discussed. KW - Biosensor KW - Level sensor KW - multi-interface measurement KW - electrical capacitance tomography KW - ECT Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1498 ER - TY - CHAP A1 - Chaiyboun, Ali A1 - Traute, Rüdiger A1 - Kiesewetter, Olaf A1 - Ahlers, Simon A1 - Müller, Gerhard A1 - Doll, Theodor T1 - Modular analytical multicomponent analysis in gas sensor arrays N2 - A multi-sensor system is a chemical sensor system which quantitatively and qualitatively records gases with a combination of cross-sensitive gas sensor arrays and pattern recognition software. This paper addresses the issue of data analysis for identification of gases in a gas sensor array. We introduce a software tool for gas sensor array configuration and simulation. It concerns thereby about a modular software package for the acquisition of data of different sensors. A signal evaluation algorithm referred to as matrix method was used specifically for the software tool. This matrix method computes the gas concentrations from the signals of a sensor array. The software tool was used for the simulation of an array of five sensors to determine gas concentration of CH4, NH3, H2, CO and C2H5OH. The results of the present simulated sensor array indicate that the software tool is capable of the following: (a) identify a gas independently of its concentration; (b) estimate the concentration of the gas, even if the system was not previously exposed to this concentration; (c) tell when a gas concentration exceeds a certain value. A gas sensor data base was build for the configuration of the software. With the data base one can create, generate and manage scenarios and source files for the simulation. With the gas sensor data base and the simulation software an on-line Web-based version was developed, with which the user can configure and simulate sensor arrays on-line. KW - Biosensor KW - Main sensitivity KW - cross sensitivity KW - matrix method KW - gas sensor array KW - modelling Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1358 ER - TY - THES A1 - Pfaff, Raphael T1 - Modelling of nonlinear systems using piecewise defined models Y1 - 2006 N1 - Coventry, Univ., Masterarbeit, 2006 ER - TY - JOUR A1 - Mistler, Michael A1 - Butenweg, Christoph A1 - Meskouris, Konstantin T1 - Modelling methods of historic masonry buildings under seismic excitation JF - Journal of seismology Y1 - 2006 U6 - http://dx.doi.org/10.1007/s10950-006-9033-z SN - 1383-4649 (Print) ; 1573-157X (E-Journal) VL - Volume 10 IS - No. 4 SP - 497 EP - 510 ER - TY - JOUR A1 - Ritz, Thomas A1 - Stender, Michael T1 - Modeling of B2B mobile commerce processes JF - International Journal of Production Economics Y1 - 2006 U6 - http://dx.doi.org/10.1016/j.ijpe.2005.05.017 SN - 0925-5273 VL - 101 IS - 1 SP - 128 EP - 139 ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Bauer, S. M. A1 - Zamuraev, L. A. T1 - Model of the transversely isotropic spherical layer for estimation of intraocular pressure changes after intravitreal injections / Bauer, S. M. ; Zamuraev, L. A. ; Kotliar, K. E. JF - Rossiiskii zhurnal biomekhaniki = Russian Journal of biomechanics. 10 (2006), H. 2 Y1 - 2006 SN - 1812-5123 SP - 41 EP - 47 PB - - ER - TY - CHAP A1 - Tymecki, Lukasz A1 - Glab, Stanislaw A1 - Koncki, Robert T1 - Miniaturized, planar ion-selective electrodes fabricated by means of thick-film technology N2 - Various planar technologies are employed for developing solid-state sensors having low cost, small size and high reproducibility; thin- and thick-film technologies are most suitable for such productions. Screen-printing is especially suitable due to its simplicity, low-cost, high reproducibility and efficiency in large-scale production. This technology enables the deposition of a thick layer and allows precise pattern control. Moreover, this is a highly economic technology, saving large amounts of the used inks. In the course of repetitions of the film-deposition procedure there is no waste of material due to additivity of this thick-film technology. Finally, the thick films can be easily and quickly deposited on inexpensive substrates. In this contribution, thick-film ion-selective electrodes based on ionophores as well as crystalline ion-selective materials dedicated for potentiometric measurements are demonstrated. Analytical parameters of these sensors are comparable with those reported for conventional potentiometric electrodes. All mentioned thick-film strip electrodes have been totally fabricated in only one, fully automated thickfilm technology, without any additional manual, chemical or electrochemical steps. In all cases simple, inexpensive, commercially available materials, i.e. flexible, plastic substrates and easily cured polymer-based pastes were used. KW - Biosensor KW - Potentiometry KW - thick-film technology KW - screen-printing KW - ion-selective electrodes Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1506 ER -