TY - CHAP A1 - Sattler, Johannes Christoph A1 - Schneider, Iesse Peer A1 - Angele, Florian A1 - Atti, Vikrama A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Development of heliostat field calibration methods: Theory and experimental test results T2 - SolarPACES conference proceedings N2 - In this work, three patent pending calibration methods for heliostat fields of central receiver systems (CRS) developed by the Solar-Institut Jülich (SIJ) of the FH Aachen University of Applied Sciences are presented. The calibration methods can either operate in a combined mode or in stand-alone mode. The first calibration method, method A, foresees that a camera matrix is placed into the receiver plane where it is subjected to concentrated solar irradiance during a measurement process. The second calibration method, method B, uses an unmanned aerial vehicle (UAV) such as a quadrocopter to automatically fly into the reflected solar irradiance cross-section of one or more heliostats (two variants of method B were tested). The third calibration method, method C, foresees a stereo central camera or multiple stereo cameras installed e.g. on the solar tower whereby the orientations of the heliostats are calculated from the location detection of spherical red markers attached to the heliostats. The most accurate method is method A which has a mean accuracy of 0.17 mrad. The mean accuracy of method B variant 1 is 1.36 mrad and of variant 2 is 1.73 mrad. Method C has a mean accuracy of 15.07 mrad. For method B there is great potential regarding improving the measurement accuracy. For method C the collected data was not sufficient for determining whether or not there is potential for improving the accuracy. KW - Heliostat Field Calibration KW - Unmanned aerial vehicle KW - UAV KW - Quadrocopter KW - Camera system Y1 - 2024 U6 - http://dx.doi.org/10.52825/solarpaces.v1i.678 SN - 2751-9899 (online) N1 - 28th International Conference on Concentrating Solar Power and Chemical Energy Systems, 27-30 September, Albuquerque, NM, USA IS - Vol. 1 PB - TIB Open Publishing CY - Hannover ER - TY - CHAP A1 - Surtees, A. J. A1 - Gillespie, A. A1 - Kern, Alexander A1 - Rousseau, A. T1 - DEVELOPMENT OF A RISK ASSESSMENT CALCULATOR BASED ON A SIMPLIFIED FORM OF THE IEC 62305-2 STANDARD ON LIGHTNING PROTECTION N2 - Neue Blitzschutznorm IEC 62305. Entwicklung einer einfachen Software zur Risikoabwägung N2 - IEC Technical Committee 81 is currently creating the new IEC 62305 series of standards on Lightning Protection. Working Group 9 is responsible for Part 2 of this series, which deals with the assessment and management of risk its CDV (Committee Draft for Voting) stage and has been circulated to National Committees for comment. The paper details the development of the Simplified IEC Risk Assessment Calculator software tool as described in Informative Annex J of IEC62305-2 Ed.1/CDV 2. This tool is intended as a simplified implementation of the more rigorous treatment of risk management found in the written document. It is designed to be relatively intuitive for users who wish to obtain an initial assessment of risk sensitivity, but should not be considered a substitute to a full understanding of the methods provided in the standard when dealing with more complicated structures or those where greater risks to personal or system operation are involved. KW - Risiko KW - Risikoabwägung KW - Blitzrisiko KW - Blitzschutz KW - Risk KW - Risk Management KW - Risk Assessment KW - Lightning Risk KW - Lightning Protection Y1 - 2004 ER - TY - CHAP A1 - Caminos, Ricardo Alexander Chico A1 - Schmitz, Pascal A1 - Atti, Vikrama A1 - Mahdi, Zahra A1 - Teixeira Boura, Cristiano José A1 - Sattler, Johannes Christoph A1 - Herrmann, Ulf A1 - Hilger, Patrick A1 - Dieckmann, Simon T1 - Development of a micro heliostat and optical qualification assessment with a 3D laser scanning method T2 - SOLARPACES 2020 N2 - The Solar-Institut Jülich (SIJ) and the companies Hilger GmbH and Heliokon GmbH from Germany have developed a small-scale cost-effective heliostat, called “micro heliostat”. Micro heliostats can be deployed in small-scale concentrated solar power (CSP) plants to concentrate the sun's radiation for electricity generation, space or domestic water heating or industrial process heat. In contrast to conventional heliostats, the special feature of a micro heliostat is that it consists of dozens of parallel-moving, interconnected, rotatable mirror facets. The mirror facets array is fixed inside a box-shaped module and is protected from weathering and wind forces by a transparent glass cover. The choice of the building materials for the box, tracking mechanism and mirrors is largely dependent on the selected production process and the intended application of the micro heliostat. Special attention was paid to the material of the tracking mechanism as this has a direct influence on the accuracy of the micro heliostat. The choice of materials for the mirror support structure and the tracking mechanism is made in favor of plastic molded parts. A qualification assessment method has been developed by the SIJ in which a 3D laser scanner is used in combination with a coordinate measuring machine (CMM). For the validation of this assessment method, a single mirror facet was scanned and the slope deviation was computed. KW - Concentrated solar power KW - Electricity generation KW - Measuring instruments KW - Heliostats KW - Global change Y1 - 2022 SN - 978-0-7354-4195-8 U6 - http://dx.doi.org/10.1063/5.0086262 SN - 1551-7616 (online) SN - 0094-243X (print) N1 - 26th International Conference on Concentrating Solar Power and Chemical Energy Systems 28 September–2 October 2020 Freiburg, Germany IS - 2445 / 1 PB - AIP conference proceedings / American Institute of Physics CY - Melville, NY ER - TY - CHAP A1 - Takenaga, Shoko A1 - Herrera, Cony F. A1 - Werner, Frederik A1 - Biselli, Manfred A1 - Schnitzler, Thomas A1 - Schöning, Michael Josef A1 - Öhlschläger, Peter A1 - Wagner, Torsten T1 - Detection of the metabolic activity of cells by differential measurements based on a single light-addressable potentiometric sensor chip T2 - 11. Dresdner Sensor-Symposium : 9.-11.12.2013 Y1 - 2013 SN - 978-3-9813484-5-3 SP - 63 EP - 67 ER - TY - CHAP A1 - Rochefort, E. de A1 - Verver, M. A1 - Grunendahl, A. A1 - Mooi, H. A1 - Butenweg, Christoph T1 - Detailed modelling of the lumbar spine for investigation of low back pain T2 - Digital Human Modeling for Design and Engineering Symposium : Iowa City, Iowa June 14-16, 2005. (SAE technical papers series ; 2005-1-2716) Y1 - 2005 U6 - http://dx.doi.org/10.4271/2005-01-2716 SN - 0096-736X SP - 1 EP - 11 PB - SAE International CY - Warrendale, Pa. ER - TY - CHAP A1 - Hardt, Arno A1 - Abdel-Gawad, A A1 - Martin, S. A1 - Reich, J. T1 - Design procedures for the Juelich QQDDQ high resolution spectrometer T2 - Proceedings, 5th International Conference on Magnet Technology (MT-5) : Rome, Italy, April 21-25, 1975 Y1 - 1975 SP - 45 EP - 51 ER - TY - CHAP A1 - Butenweg, Christoph A1 - Rajan, Sreelakshmy T1 - Design and construction techniques of AAC masonry buildings in earthquakes regions T2 - 10 years Xella research in Building Materials : Symposium on the 4th and 5th of September, Potsdam 2014 Y1 - 2014 ER - TY - CHAP A1 - Dielmann, Klaus-Peter T1 - Darstellung des Erneuerbaren Energiegesetzes (EEG) und dessen Auswirkungen N2 - Erneuerbares Energien-Gesetz: Anwendungsbereich, Abnahme- und Vergütungspflicht, Vergütungssätze, Netzkosten, Ausgleichsregelungen Auswirkungen des EEG: Photovoltaik, Windkraft, Biomasse, Wasserkraft, Klär-, Deponie- und Grubengas, Geothermie Zusammenfassung und Ausblick KW - Energierecht KW - Erneuerbares Energiengesetz Y1 - 2002 ER - TY - CHAP A1 - Butenweg, Christoph A1 - Marinkovic, Marko T1 - Damage reduction system for masonry infill walls under seismic loading T2 - ce/papers N2 - Reinforced concrete (RC) frames with masonry infills are frequently used in seismic regions all over the world. Generally masonry infills are considered as nonstructural elements and thus are typically neglected in the design process. However, the observations made after strong earthquakes have shown that masonry infills can modify the dynamic behavior of the structure significantly. The consequences were total collapses of buildings and loss of human lives. This paper presents the new system INODIS (Innovative Decoupled Infill System) developed within the European research project INSYSME (Innovative Systems for Earthquake Resistant Masonry Enclosures in RC Buildings). INODIS decouples the frame and the masonry infill by means of special U-shaped rubbers placed in between frame and infill. The effectiveness of the system was investigated by means of full scale tests on RC frames with masonry infills subjected to in-plane and out-of-plane loading. Furthermore small specimen tests were conducted to determine material characteristics of the components and the resistances of the connections. Finally, a micromodel was developed to simulate the in-plane behavior of RC frames infilled with AAC blocks with and without installation of the INODIS system. KW - earthquakes KW - in-plane and out-of-plane failure KW - INODIS KW - RC frames Y1 - 2018 U6 - http://dx.doi.org/10.1002/cepa.863 N1 - Special Issue: ICAAC ‐ 6th International Conference on Autoclaved Aerated Concrete VL - 2 IS - 4 SP - 267 EP - 273 PB - Ernst & Sohn Verlag CY - Berlin ER - TY - CHAP A1 - Schulte, Jonas A1 - Schwager, Christian A1 - Frantz, Cathy A1 - Schloms, Felix A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Control concept for a molten salt receiver in star design: Development, optimization and testing with cloud passage scenarios T2 - SolarPACES conference proceedings N2 - A promising approach to reduce the system costs of molten salt solar receivers is to enable the irradiation of the absorber tubes on both sides. The star design is an innovative receiver design, pursuing this approach. The unconventional design leads to new challenges in controlling the system. This paper presents a control concept for a molten salt receiver system in star design. The control parameters are optimized in a defined test cycle by minimizing a cost function. The control concept is tested in realistic cloud passage scenarios based on real weather data. During these tests, the control system showed no sign of unstable behavior, but to perform sufficiently in every scenario further research and development like integrating Model Predictive Controls (MPCs) need to be done. The presented concept is a starting point to do so. KW - Molten salt receiver KW - Star design KW - Control optimization KW - Cloud passages Y1 - 2023 U6 - http://dx.doi.org/10.52825/solarpaces.v1i.693 SN - 2751-9899 (online) N1 - 28th International Conference on Concentrating Solar Power and Chemical Energy Systems, 27-30 September, Albuquerque, NM, USA IS - Vol. 1 PB - TIB Open Publishing CY - Hannover ER - TY - CHAP A1 - Paulsen, Svea A1 - Hoffstadt, Kevin A1 - Krafft, Simone A1 - Leite, A. A1 - Zang, J. A1 - Fonseca-Zang, W. A1 - Kuperjans, Isabel T1 - Continuous biogas production from sugarcane as sole substrate T2 - Energy Reports Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.egyr.2019.08.035 N1 - 6th International Conference on Energy and Environment Research, ICEER 2019, 22–25 July, University of Aveiro, Portugal VL - 6 IS - Supplement 1 SP - 153 EP - 158 PB - Elsevier ER - TY - CHAP A1 - Kern, Alexander A1 - Krichel, Frank T1 - Considerations about the lightning protection system of mains independent renewable energy hybrid-systems - practical experiences N2 - In the paper a lightning protection design concept for renewable energy hybrid-systems without power mains connection is described. Based on a risk analysis protection measures against direct strikes and overvoltages are shown in an overview. The design concept is realized exemplarily for the hybrid-system VATALI on the Greek island Crete. VATALI, not lightning protected at that time, was a victim of a lightning strike in the year 2000 causing destructions and damages of some mechanical and electrical components with costs of approx. 60.000 €. The hardware costs for the protection measures were about 15.000 €: about 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection. KW - Blitzschutz KW - Erneuerbare Energien KW - Hybridsystem KW - Photovoltaikanlage KW - Windenergieanlage KW - Lightning protection KW - renewable energy KW - hybrid system KW - photovoltaic system KW - wind turbine Y1 - 2002 ER - TY - CHAP A1 - Latzke, Markus A1 - Alexopoulos, Spiros A1 - Kronhardt, Valentina A1 - Rendón, Carlos A1 - Sattler, Johannes, Christoph T1 - Comparison of Potential Sites in China for Erecting a Hybrid Solar Tower Power Plant with Air Receiver T2 - Energy Procedia Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.egypro.2015.03.142 SN - 1876-6102 N1 - International Conference on Concentrating Solar Power and Chemical Energy Systems, SolarPACES 2014, Beijing, China SP - 1327 EP - 1334 ER - TY - CHAP A1 - Höfler, M. A1 - Kneer, R. A1 - Groß, Rolf Fritz A1 - Kehrmann, K. ED - Vorobieff, P. T1 - Chemical determination of oxygen transfer rates, transfer efficiencies and interphases evoked by aeration elements for liquid flows T2 - Computational Methods in Multiphase Flow VIII. - (WIT Transactions on Engineering Sciences ; Volume 89) Y1 - 2015 SN - 978-1-84564-946-3 (Print-Ausgabe) SN - 978-1-84564-947-0 (Online-Ausgabe) SN - 1746-4471 SP - 89 EP - 101 PB - WIT Press CY - Southampton ER - TY - CHAP A1 - Kaspar, K. A1 - Groebel, Simone A1 - Kuperjans, Isabel A1 - Dielmann, Klaus-Peter A1 - Selmer, Thorsten T1 - Charakterisierung der Biozönose von Biogasfermentern in Abhängigkeit verschiedener Substrate T2 - Biogas 2013 : 6. Innovationskongress, 23. - 24.05.2013, Osnabrück, Tagungsband Y1 - 2013 SN - 978-3-9813776-3-7 SP - 69 EP - 74 PB - Profair Consult+Project CY - Hildesheim ER - TY - CHAP A1 - Butenweg, Christoph A1 - Gellert, Christoph A1 - Reindl, Lukas T1 - Capacity design of masonry buildings under cyclic loading T2 - Seismic Risk : Earthquakes in North-Western Europe ; international colloquium ; Liège on 11 and 12 September 2008 / Belgian Seismic Group (BeSeiG). Ed.: T. Camlebeeck ... Y1 - 2008 SN - 978-2-87456-063-7 SP - 201 EP - 208 PB - Editions de l'Université de Liège CY - Liège ER - TY - CHAP A1 - Kalker, Ines A1 - Toll, B. A1 - Holler, Stefan A1 - Butenweg, Christoph A1 - Topping, B. H. V. A1 - Mota Soares, C. A. T1 - Capacity analysis of textile retrofitted unreinforced masonry T2 - Proceedings of the Seventh International Conference on Computational Structures Technology : [Lisbon, Portugal, 7 - 9 September 2004] / ed. by B. H. V. Topping ... Y1 - 2004 SN - 0-948749-95-4 U6 - http://dx.doi.org/10.4203/ccp.79.194 SP - 431 EP - 432 PB - Civil-Comp Press CY - Stirling ER - TY - CHAP A1 - Kern, Alexander A1 - Beierl, Ottmar A1 - Zischank, Wolfgang T1 - Calculation of the separation distance according to IEC 62305-3: 2006-10 - Remarks for the application and simplified methods N2 - [Paper of the X International Symposium on Lightning Protection 9th - 13th November, 2009 - Curitiba, Brazil. 6 pages] The international standard IEC 62305-3, published in 2006, requires as an integral part of the lightning protection system (LPS) the consideration of a separation distance between the conductors of the LPS and metal and electrical installations inside the structure to be protected. IEC 62305-3 gives two different methods for this calculation: a standard, simplified approach and a more detailed approach, which differ especially regarding the treatment of the current sharing effect on the LPS conductors. Hence, different results for the separation distance are possible, leading to some discrepancies in the use of the standard. The standard approach defined in the main part (Clause 6.3) and in Annex C of the standard in some cases may lead to a severe oversizing of the required separation distance. The detailed approach described in Annex E naturally gives more correct results. However, a calculation of the current sharing amongst all parts of the air-termination and downconductor network is necessary, in many cases requiring the use of network analysis programs. In this paper simplified methods for the assessment of the current sharing are presented, which are easy to use as well as sufficiently adequate. KW - Blitzschutz KW - Lightning protection Y1 - 2009 N1 - Paper in: [10. International Symposium on Lightning Protection 9. 13. November 2009, Curitiba, Brasilien. 6 Seiten] ER - TY - CHAP A1 - Pfundt, H. A1 - Vogelsang, D. A1 - Gerling, Ulrich T1 - Calculation of the crust profile in aluminium reduction cells by thermal computer modelling T2 - Light metals 1989 : 118th annual meeting of the Minerals, Metals and Materials Society, Las Vegas, NV, Feb. 27 - Mar. 03. 1989 Y1 - 1988 SP - 371 EP - 377 PB - Minerals, Metals and Materials Soc. CY - Warrendale, Pa. ER - TY - CHAP A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Calculation of interception efficiencies for mesh-type air-terminations according to IEC 62305-3 using a dynamic electro-geometrical model T2 - International Conference on Lightning Protection (ICLP) : 2 - 7 Sept. 2012, Vienna Y1 - 2012 SN - 978-1-4673-1896-9 (E-Book) ; 978-1-4673-1898-3 (Print) SP - 1 EP - 6 PB - IEEE CY - Piscataway, NJ ER -