TY - JOUR A1 - Dikta, Gerhard A1 - Reißel, Martin A1 - Harlaß, Carsten T1 - Semi-parametric survival function estimators deduced from an identifying Volterra type integral equation JF - Journal of multivariate analysis N2 - Based on an identifying Volterra type integral equation for randomly right censored observations from a lifetime distribution function F, we solve the corresponding estimating equation by an explicit and implicit Euler scheme. While the first approach results in some known estimators, the second one produces new semi-parametric and pre-smoothed Kaplan–Meier estimators which are real distribution functions rather than sub-distribution functions as the former ones are. This property of the new estimators is particular useful if one wants to estimate the expected lifetime restricted to the support of the observation time. Specifically, we focus on estimation under the semi-parametric random censorship model (SRCM), that is, a random censorship model where the conditional expectation of the censoring indicator given the observation belongs to a parametric family. We show that some estimated linear functionals which are based on the new semi-parametric estimator are strong consistent, asymptotically normal, and efficient under SRCM. In a small simulation study, the performance of the new estimator is illustrated under moderate sample sizes. Finally, we apply the new estimator to a well-known real dataset. KW - Volterra integral equation KW - Product-integration KW - Asymptotic efficiency KW - Semi-parametric random censorship model KW - Censored data KW - Survival analysis Y1 - 2016 U6 - https://doi.org/10.1016/j.jmva.2016.02.008 IS - 147 SP - 273 EP - 284 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Marinova, V. A1 - Kerroumi, I. A1 - Lintermann, A. A1 - Göbbert, J.H. A1 - Moulinec, C. A1 - Rible, S. A1 - Fournier, Y. A1 - Behbahani, Mehdi T1 - Numerical Analysis of the FDA Centrifugal Blood Pump T2 - NIC Symposium 2016 Y1 - 2016 SN - 978-3-95806-109-5 SP - 355 EP - 364 ER - TY - JOUR A1 - Frotscher, Ralf A1 - Muanghong, Danita A1 - Dursun, Gözde A1 - Goßmann, Matthias A1 - Temiz Artmann, Aysegül A1 - Staat, Manfred T1 - Sample-specific adaption of an improved electro-mechanical model of in vitro cardiac tissue JF - Journal of Biomechanics N2 - We present an electromechanically coupled computational model for the investigation of a thin cardiac tissue construct consisting of human-induced pluripotent stem cell-derived atrial, ventricular and sinoatrial cardiomyocytes. The mechanical and electrophysiological parts of the finite element model, as well as their coupling are explained in detail. The model is implemented in the open source finite element code Code_Aster and is employed for the simulation of a thin circular membrane deflected by a monolayer of autonomously beating, circular, thin cardiac tissue. Two cardio-active drugs, S-Bay K8644 and veratridine, are applied in experiments and simulations and are investigated with respect to their chronotropic effects on the tissue. These results demonstrate the potential of coupled micro- and macroscopic electromechanical models of cardiac tissue to be adapted to experimental results at the cellular level. Further model improvements are discussed taking into account experimentally measurable quantities that can easily be extracted from the obtained experimental results. The goal is to estimate the potential to adapt the presented model to sample specific cell cultures. KW - hiPS cardiomyocytes KW - Homogenization KW - Hodgkin–Huxley models KW - Frequency adaption KW - Electromechanical modeling KW - Drug simulation KW - Computational biomechanics KW - Cardiac tissue Y1 - 2016 U6 - https://doi.org/10.1016/j.jbiomech.2016.01.039 SN - 0021-9290 (Print) SN - 1873-2380 (Online) VL - 49 IS - 12 SP - 2428 EP - 2435 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Effect of wind on flight style optimisation in ski jumping T2 - 15th International Symposium on Computer Simulation in Biomechanics ; July 9th-11th 2015, Edinburgh, UK Y1 - 2016 SP - 53 EP - 54 PB - The University of Edinburgh ; Loughborough University CY - Edinburgh ER - TY - RPRT A1 - Bhattarai, Aroj A1 - Frotscher, Ralf A1 - Durong, Minh Tuán A1 - Staat, Manfred T1 - Schlussbericht zu BINGO. Optimierung des Systems Netzimplantat-Beckenboden zur therapeutischen Gewebeverstärkung nach der Integraltheorie. Y1 - 2016 N1 - Förderkennzeichen BMBF 03FH073PX2 CY - Aachen ER - TY - JOUR A1 - Goßmann, Matthias A1 - Frotscher, Ralf A1 - Linder, Peter A1 - Bayer, Robin A1 - Epple, U. A1 - Staat, Manfred A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard T1 - Mechano-pharmacological characterization of cardiomyocytes derived from human induced pluripotent stem cells JF - Cellular physiology and biochemistry N2 - Background/Aims: Common systems for the quantification of cellular contraction rely on animal-based models, complex experimental setups or indirect approaches. The herein presented CellDrum technology for testing mechanical tension of cellular monolayers and thin tissue constructs has the potential to scale-up mechanical testing towards medium-throughput analyses. Using hiPS-Cardiac Myocytes (hiPS-CMs) it represents a new perspective of drug testing and brings us closer to personalized drug medication. Methods: In the present study, monolayers of self-beating hiPS-CMs were grown on ultra-thin circular silicone membranes and deflect under the weight of the culture medium. Rhythmic contractions of the hiPS-CMs induced variations of the membrane deflection. The recorded contraction-relaxation-cycles were analyzed with respect to their amplitudes, durations, time integrals and frequencies. Besides unstimulated force and tensile stress, we investigated the effects of agonists and antagonists acting on Ca²⁺ channels (S-Bay K8644/verapamil) and Na⁺ channels (veratridine/lidocaine). Results: The measured data and simulations for pharmacologically unstimulated contraction resembled findings in native human heart tissue, while the pharmacological dose-response curves were highly accurate and consistent with reference data. Conclusion: We conclude that the combination of the CellDrum with hiPS-CMs offers a fast, facile and precise system for pharmacological, toxicological studies and offers new preclinical basic research potential. KW - Inotropic compounds KW - Pharmacology KW - Ion channels KW - CellDrum KW - Heart tissue culture KW - Induced pluripotent stem cells KW - Cardiac myocytes Y1 - 2016 U6 - https://doi.org/10.1159/000443124 SN - 1421-9778 (Online) SN - 1015-8987 (Print) VL - 38 IS - 3 SP - 1182 EP - 1198 PB - Karger CY - Basel ER - TY - CHAP A1 - Laack, Walter van T1 - Schnittstelle Tod: Wo stehen wir nach 40 Jahren NTE-Forschung? Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:101:1-201603132912 SN - 978-3-936624-30-4 (Print-Ausgabe) SN - 978-3-936624-32-8 (Online-Ausgabe) N1 - Tagungsbeiträge des 4. Europäischen Seminars am 07. November 2015 in Aachen zum Thema Nahtoderfahrungen mit dem Serientitel: "Schnittstelle Tod" PB - van Laack GmbH CY - Aachen ER - TY - JOUR A1 - Albanna, Walid A1 - Conzen, Catharina A1 - Weiss, Miriam A1 - Clusmann, Hans A1 - Fuest, Matthias A1 - Mueller, Marguerite A1 - Brockmann, Marc Alexander A1 - Vilser, Walthard A1 - Schmidt-Trucksäss, Arno A1 - Hoellig, Anke A1 - Seiz, Marcel A1 - Thomé, Claudius A1 - Kotliar, Konstantin A1 - Schubert, Gerrit Alexander T1 - Retinal Vessel Analysis (RVA) in the context of subarachnoid hemorrhage: A proof of concept study JF - PLoS ONE N2 - Background Timely detection of impending delayed cerebral ischemia after subarachnoid hemorrhage (SAH) is essential to improve outcome, but poses a diagnostic challenge. Retinal vessels as an embryological part of the intracranial vasculature are easily accessible for analysis and may hold the key to a new and non-invasive monitoring technique. This investigation aims to determine the feasibility of standardized retinal vessel analysis (RVA) in the context of SAH. Methods In a prospective pilot study, we performed RVA in six patients awake and cooperative with SAH in the acute phase (day 2–14) and eight patients at the time of follow-up (mean 4.6±1.7months after SAH), and included 33 age-matched healthy controls. Data was acquired using a manoeuvrable Dynamic Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and neurovascular coupling. Results Image quality was satisfactory in the majority of cases (93.3%). In the acute phase after SAH, retinal arteries were significantly dilated when compared to the control group (124.2±4.3MU vs 110.9±11.4MU, p<0.01), a difference that persisted to a lesser extent in the later stage of the disease (122.7±17.2MU, p<0.05). Testing for neurovascular coupling showed a trend towards impaired primary vasodilation and secondary vasoconstriction (p = 0.08, p = 0.09 resp.) initially and partial recovery at the time of follow-up, indicating a relative improvement in a time-dependent fashion. Conclusion RVA is technically feasible in patients with SAH and can detect fluctuations in vessel diameter and autoregulation even in less severely affected patients. Preliminary data suggests potential for RVA as a new and non-invasive tool for advanced SAH monitoring, but clinical relevance and prognostic value will have to be determined in a larger cohort. Y1 - 2016 U6 - https://doi.org/10.1371/journal.pone.0158781 SN - 1932-6203 VL - 11 IS - 7 PB - PLOS CY - San Francisco ER - TY - JOUR A1 - Murib, M. S. A1 - Yeap, W. S. A1 - Eurlings, Y. A1 - Grinsven, B. van A1 - Boyen, H.-G. A1 - Conings, B. A1 - Michiels, L. A1 - Ameloot, Marcel A1 - Carleer, R. A1 - Warmer, J. A1 - Kaul, P. A1 - Haenen, K. A1 - Schöning, Michael Josef A1 - Ceuninck, W. de A1 - Wagner, P. T1 - Heat-transfer based characterization of DNA on synthetic sapphire chips JF - Sensors and Actuators B: Chemical N2 - In this study, we show that synthetic sapphire (Al₂O₃), an established implant material, can also serve as a platform material for biosensors comparable to nanocrystalline diamond. Sapphire chips, beads, and powder were first modified with (3-aminopropyl) triethoxysilane (APTES), followed by succinic anhydride (SA), and finally single-stranded probe DNA was EDC coupled to the functionalized layer. The presence of the APTES-SA layer on sapphire powders was confirmed by thermogravimetric analyis and Fourier-transform infrared spectroscopy. Using planar sapphire chips as substrates and X-ray photoelectron spectroscopy (XPS) as surface-sensitive tool, the sequence of individual layers was analyzed with respect to their chemical state, enabling the quantification of areal densities of the involved molecular units. Fluorescence microscopy was used to demonstrate the hybridization of fluorescently tagged target DNA to the probe DNA, including denaturation- and re-hybridization experiments. Due to its high thermal conductivity, synthetic sapphire is especially suitable as a chip material for the heat-transfer method, which was employed to distinguish complementary- and non-complementary DNA duplexes containing single-nucleotide polymorphisms. These results indicate that it is possible to detect mutations electronically with a chemically resilient and electrically insulating chip material. Y1 - 2016 U6 - https://doi.org/10.1016/j.snb.2016.02.027 SN - 0925-4005 VL - 230 IS - 230 SP - 260 EP - 271 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kolditz, Melanie A1 - Albin, Thivaharan A1 - Abel, Dirk A1 - Fasse, Alessandro A1 - Brüggemann, Gert-Peter A1 - Albracht, Kirsten T1 - Evaluation of foot position and orientation as manipulated variables to control external knee adduction moments in leg extension training JF - Computer methods and programs in biomedicine N2 - Background and Objective Effective leg extension training at a leg press requires high forces, which need to be controlled to avoid training-induced damage. In order to avoid high external knee adduction moments, which are one reason for unphysiological loadings on knee joint structures, both training movements and the whole reaction force vector need to be observed. In this study, the applicability of lateral and medial changes in foot orientation and position as possible manipulated variables to control external knee adduction moments is investigated. As secondary parameters both the medio-lateral position of the center of pressure and the frontal-plane orientation of the reaction force vector are analyzed. Methods Knee adduction moments are estimated using a dynamic model of the musculoskeletal system together with the measured reaction force vector and the motion of the subject by solving the inverse kinematic and dynamic problem. Six different foot conditions with varying positions and orientations of the foot in a static leg press are evaluated and compared to a neutral foot position. Results Both lateral and medial wedges under the foot and medial and lateral shifts of the foot can influence external knee adduction moments in the presented study with six healthy subjects. Different effects are observed with the varying conditions: the pose of the leg is changed and the direction and center of pressure of the reaction force vector is influenced. Each effect results in a different direction or center of pressure of the reaction force vector. Conclusions The results allow the conclusion that foot position and orientation can be used as manipulated variables in a control loop to actively control knee adduction moments in leg extension training. KW - External knee adduction moments KW - Manipulated variables KW - Inverse dynamic problem KW - Inverse kinematic problem KW - Musculoskeletal model Y1 - 2016 U6 - https://doi.org/10.1016/j.cmpb.2016.09.005 SN - 0169-2607 N1 - Part of special issue: "SI: Personalised Models and System Identification" VL - 171 SP - 81 EP - 86 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Droszez, Anna A1 - Sanno, Maximilian A1 - Goldmann, Jan-Peter A1 - Albracht, Kirsten A1 - Brüggemann, Gert-Peter A1 - Braunstein, Bjoern T1 - Differences between take-off behavior during vertical jumps and two artistic elements T2 - 34th International Conference of Biomechanics in Sport, Tsukuba, Japan, July 18-22, 2016 Y1 - 2016 SN - 1999-4168 SP - 577 EP - 580 ER - TY - CHAP A1 - Kolditz, Melanie A1 - Albin, Thivaharan A1 - Albracht, Kirsten A1 - Brüggemann, Gert-Peter A1 - Abel, Dirk T1 - Isokinematic leg extension training with an industrial robot T2 - 6th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) June 26-29, 2016. UTown, Singapore Y1 - 2016 U6 - https://doi.org/10.1109/BIOROB.2016.7523750 SP - 950 EP - 955 ER - TY - JOUR A1 - Belavy, Daniel L. A1 - Albracht, Kirsten A1 - Brüggemann, Gert-Peter A1 - Vergroesen, Pieter-Paul A. A1 - Dieen, Jaap H. van T1 - Can exercise positively influence the intervertebral disc? JF - Sports Medicine N2 - To better understand what kinds of sports and exercise could be beneficial for the intervertebral disc (IVD), we performed a review to synthesise the literature on IVD adaptation with loading and exercise. The state of the literature did not permit a systematic review; therefore, we performed a narrative review. The majority of the available data come from cell or whole-disc loading models and animal exercise models. However, some studies have examined the impact of specific sports on IVD degeneration in humans and acute exercise on disc size. Based on the data available in the literature, loading types that are likely beneficial to the IVD are dynamic, axial, at slow to moderate movement speeds, and of a magnitude experienced in walking and jogging. Static loading, torsional loading, flexion with compression, rapid loading, high-impact loading and explosive tasks are likely detrimental for the IVD. Reduced physical activity and disuse appear to be detrimental for the IVD. We also consider the impact of genetics and the likelihood of a ‘critical period’ for the effect of exercise in IVD development. The current review summarises the literature to increase awareness amongst exercise, rehabilitation and ergonomic professionals regarding IVD health and provides recommendations on future directions in research. KW - Intradiscal Pressure KW - Annulus Fibrosus KW - Disc Degeneration KW - Nucleus Pulposus KW - Intervertebral Disc Y1 - 2016 U6 - https://doi.org/10.1007/s40279-015-0444-2 SN - 1179-2035 VL - 46 IS - 4 SP - 473 EP - 485 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kolditz, Melanie A1 - Albin, Thivaharan A1 - Brüggemann, Gert-Peter A1 - Abel, Dirk A1 - Albracht, Kirsten T1 - Robotergestütztes System für ein verbessertes neuromuskuläres Aufbautraining der Beinstrecker JF - at - Automatisierungstechnik N2 - Neuromuskuläres Aufbautraining der Beinstrecker ist ein wichtiger Bestandteil in der Rehabilitation und Prävention von Muskel-Skelett-Erkrankungen. Effektives Training erfordert hohe Muskelkräfte, die gleichzeitig hohe Belastungen von bereits geschädigten Strukturen bedeuten. Um trainingsinduzierte Schädigungen zu vermeiden, müssen diese Kräfte kontrolliert werden. Mit heutigen Trainingsgeräten können diese Ziele allerdings nicht erreicht werden. Für ein sicheres und effektives Training sollen durch den Einsatz der Robotik, Sensorik, eines Regelkreises sowie Muskel-Skelett-Modellen Belastungen am Zielgewebe direkt berechnet und kontrolliert werden. Auf Basis zweier Vorstudien zu möglichen Stellgrößen wird der Aufbau eines robotischen Systems vorgestellt, das sowohl für Forschungszwecke als auch zur Entwicklung neuartiger Trainingsgeräte verwendet werden kann. Y1 - 2016 U6 - https://doi.org/10.1515/auto-2016-0044 SN - 2196-677X VL - 64 IS - 11 SP - 905 EP - 914 PB - De Gruyter CY - Berlin ER -