TY - JOUR A1 - Bank, Bart L. van de A1 - Orzada, Stephan A1 - Smits, Frits A1 - Lagemaat, Miriam W. A1 - Rodgers, Christopher T. A1 - Bitz, Andreas A1 - Scheenen, Tom W. J. T1 - Optimized (31) P MRS in the human brain at 7 T with a dedicated RF coil setup JF - NMR in Biomedicine Y1 - 2015 U6 - http://dx.doi.org/10.1002/nbm.3422 SN - 1099-1492 VL - 28 IS - 11 SP - 1570 EP - 1578 PB - Wiley CY - Weinheim ER - TY - CHAP A1 - Bitz, Andreas A1 - Alaydrus, M. A1 - Streckert, J. A1 - Hansen, V. T1 - Combination of the hybrid/sup [2]/-method and the FDTD-method for solution of boundary value problems with electrically large and high-resolution bodies T2 - IEEE Antennas and Propagation Society International Symposium (IEEE Cat. No.02CH37313) 2002 : San Antonio, TX, USA, 16-21 June Y1 - 2002 SN - 0-7803-7330-8 U6 - http://dx.doi.org/10.1109/APS.2002.1018209 SP - 278 EP - 281 PB - IEEE CY - Piscataway, NJ ER - TY - CHAP A1 - Bitz, Andreas A1 - Alaydrus, M. A1 - Streckert, J. A1 - Hansen, V.W. T1 - Absorption rates inside human body due to radiated electro-magnetic fields of multi-band base station antennas. Boundary value problems with electrically large and high-resolution bodies T2 - 24th BEMS Annual Meeting, Quebec City, Quebec, Canada, 23 - 27 June 2002 Y1 - 2002 SP - 40 EP - 41 PB - Bioelectromagnetics Society CY - Frederick, MD ER - TY - CHAP A1 - Bitz, Andreas A1 - Alaydrus, M. A1 - Streckert, J. A1 - Hansen, V.W. T1 - Base station antennas embedded in complex environments: rf exposure in controlled areas T2 - 23rd BEMS Annual Meeting, St. Paul, Minnesota, USA, 49-50, June 2001 Y1 - 2001 SP - 49 EP - 50 PB - Bioelectromagnetics Society CY - Frederick, MD ER - TY - CHAP A1 - Bitz, Andreas A1 - El Ouardi, A. A1 - Streckert, J. A1 - Hansen, V. T1 - Efficient calculation of human exposure in front of base station antennas by a combination of the FDTD and Hybrid(2)-method T2 - Proceedings of the 16th International Zurich Symposium on Electromagnetic Compatibility, Topical Meeting on Biomedical EMC, Zurich, Switzerland, February 2005 Y1 - 2005 SN - 3-9521199-9-7 SP - 115 EP - 118 PB - ETH Zentrum CY - Zürich ER - TY - JOUR A1 - Bitz, Andreas A1 - Felder, Jorg A1 - Wittig, Tilmann T1 - Designing MRI Coils with Aid of Simulation JF - Microwaves & RF Y1 - 2013 SN - 0745-2993 VL - 52 IS - 7 SP - 56 PB - Penton CY - Cleveland, Ohio ER - TY - CHAP A1 - Bitz, Andreas A1 - Klomp, D.W. A1 - Ladd, M.E. T1 - Experimental and numerical determination of SAR and temperature distribution of a human endorectal coil for MR imaging of the prostate at 7T (903.) T2 - 16th annual ISMRM scientific meeting and exhibition 2008 : Toronto, Ontario, Canada, 3 - 9 May 2008 Y1 - 2009 SN - 978-1-61567-196-0 PB - Curran CY - Red Hook, NY ER - TY - CHAP A1 - Bitz, Andreas A1 - Kobus, Thiele A1 - Scheenen, Tom W. J. A1 - Ladd, Mark E. T1 - RF Safety of the Combination of a 31P Tx/Rx Endorectal Coil & a 1H Tx/Rx Body Array for 31P MRSI of the Prostate at 7T (311.) T2 - 20th Annual ISMRM scientific meeting and exhibition 2012 : Melbourne, Australia, 5 - 11 May 2012 Y1 - 2013 SN - 978-1-62276-943-8 SN - 1545-4428 IS - Volume 1 SP - 311 PB - Curran CY - Red Hook, NY ER - TY - CHAP A1 - Bitz, Andreas A1 - Kraff, O. A1 - Orzada, S. A1 - Maderwald, S. A1 - Brote, I. A1 - Johst, S. A1 - Ladd, E. T1 - Assessment of RF Safety of Transmit Coils at 7 Tesla by Experimental and Numerical Procedures (490.) T2 - 19th annual ISMRM scientific meeting and exhibition 2011 : Montreal, Quebec, Canada, 7 - 13 May 2011 Y1 - 2012 SN - 978-1-61839-284-8 IS - Volume 1 SP - 475 PB - Curran CY - Red Hook, NY ER - TY - CHAP A1 - Bitz, Andreas A1 - Kraff, O. A1 - Orzada, S. A1 - Maderwald, S. A1 - Brote, I. A1 - Ladd, M. T1 - Experimental and Numerical Assessment of RF Safety of Transmit Coils at 7 Tesla T2 - ISMRM workshop on MR safety 2010 : RF heating of the human in MRI : workshop series. The Washington County Historic Courthouse, Stillwater, Minnesota, USA, 15 - 17 October 2010 Y1 - 2010 SN - 978-1-62276-088-6 SP - 195 ER - TY - CHAP A1 - Bitz, Andreas A1 - Streckert, J. A1 - Hansen, V.W. A1 - Buschmann, J. T1 - RF exposure of non restrained animals in an overmoded radial waveguide T2 - 22nd BEMS Annual Meeting, Munich, Germany, 2000 Y1 - 2000 SP - 63 PB - Bioelectromagnetics Society CY - Frederick, MD ER - TY - CHAP A1 - Bitz, Andreas A1 - Streckert, J. A1 - Hansen, V.W. A1 - Stogbauer, F. ED - Hietanen, Maila ED - Jokela, Kari ED - Juutilainen, Jukka ED - Työterveyslaitos, T1 - Shielded RF-exposure system with an integrated LF-measuring system for in vitro experiments with cell-layers T2 - Proceedings of the Ebea 2001 : 5th International Congress of the European Bioelectromagnetics Association (Ebea) ; 6-8 September 2001, Marina Congress Center, Helsinki, Finland Y1 - 2001 SN - 9789518024401 SP - 67 EP - 68 PB - Finnish Institute of Occupational Health CY - Helsinki ER - TY - CHAP A1 - Bitz, Andreas A1 - Streckert, J.R. A1 - Hansen, V.W. A1 - Lerchl, A. ED - Danesy, Dorothea T1 - Freely moving or restrained animals in bioelec-tromagnetic experiments - pros and cons T2 - AP 2000 : Millennium Conference on Antennas & Propagation, Davos, Switzerland, 9 - 14 April 2000 Y1 - 2000 IS - Band 1 SP - 489 PB - ESA Publications Division, ESTEC CY - Noordwijk ER - TY - JOUR A1 - Bitz, Andreas A1 - Zhou, Yi A1 - El Quardi, Abdessamad A1 - Streckert, Joachim T1 - Occupational Exposure at Mobile Communication Base Station Antenna Sites JF - Frequenz Y1 - 2009 U6 - http://dx.doi.org/10.1515/FREQ.2009.63.7-8.123 SN - 2191-6349 VL - 63 IS - 7-8 SP - 123 EP - 128 ER - TY - JOUR A1 - Chen, Bixia A1 - Schoemberg, Tobias A1 - Kraff, Oliver A1 - Dammann, Philipp A1 - Bitz, Andreas A1 - Schlamann, Marc A1 - Quick, Harald H. A1 - Ladd, Mark E. A1 - Sure, Ulrich A1 - Wrede, Karsten H. T1 - Cranial fixation plates in cerebral magnetic resonance imaging: a 3 and 7 Tesla in vivo image quality study JF - Magnetic Resonance Materials in Physics, Biology and Medicine N2 - Objective This study assesses and quantifies impairment of postoperative magnetic resonance imaging (MRI) at 7 Tesla (T) after implantation of titanium cranial fixation plates (CFPs) for neurosurgical bone flap fixation. Materials and methods The study group comprised five patients who were intra-individually examined with 3 and 7 T MRI preoperatively and postoperatively (within 72 h/3 months) after implantation of CFPs. Acquired sequences included T₁-weighted magnetization-prepared rapid-acquisition gradient-echo (MPRAGE), T₂-weighted turbo-spin-echo (TSE) imaging, and susceptibility-weighted imaging (SWI). Two experienced neurosurgeons and a neuroradiologist rated image quality and the presence of artifacts in consensus reading. Results Minor artifacts occurred around the CFPs in MPRAGE and T2 TSE at both field strengths, with no significant differences between 3 and 7 T. In SWI, artifacts were accentuated in the early postoperative scans at both field strengths due to intracranial air and hemorrhagic remnants. After resorption, the brain tissue directly adjacent to skull bone could still be assessed. Image quality after 3 months was equal to the preoperative examinations at 3 and 7 T. Conclusion Image quality after CFP implantation was not significantly impaired in 7 T MRI, and artifacts were comparable to those in 3 T MRI. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s10334-016-0548-1 SN - 1352-8661 VL - 29 IS - 3 SP - 389 EP - 398 PB - Springer CY - Berlin ER - TY - JOUR A1 - El Quardi, A. A1 - Streckert, J. A1 - Bitz, Andreas A1 - Münkner, S. A1 - Engel, J. A1 - Hansen, V. T1 - New fin-line devices for radiofrequency exposure of small biological samples in vitro allowing whole-cell patch clamp recordings JF - Bioelectromagnetics N2 - The development and analysis of three waveguides for the exposure of small biological in vitro samples to mobile communication signals at 900 MHz (GSM, Global System for Mobile Communications), 1.8 GHz (GSM), and 2 GHz (UMTS, Universal Mobile Telecommunications System) is presented. The waveguides were based on a fin-line concept and the chamber containing the samples bathed in extracellular solution was placed onto two fins with a slot in between, where the exposure field concentrates. Measures were taken to allow for patch clamp recordings during radiofrequency (RF) exposure. The necessary power for the achievement of the maximum desired specific absorption rate (SAR) of 20 W/kg (average over the mass of the solution) was approximately Pin = 50 mW, Pin = 19 mW, and Pin = 18 mW for the 900 MHz, 1800 MHz, and 2 GHz devices, respectively. At 20 W/kg, a slight RF-induced temperature elevation in the solution of no more than 0.3 °C was detected, while no thermal offsets due to the electromagnetic exposure could be detected at the lower SAR settings (2, 0.2, and 0.02 W/kg). A deviation of 10% from the intended solution volume yielded a calculated SAR deviation of 8% from the desired value. A maximum ±10% variation in the local SAR could occur when the position of the patch clamp electrode was altered within the area where the cells to be investigated were located. Y1 - 2011 U6 - http://dx.doi.org/10.1002/bem.20621 SN - 1521-186X VL - 32 IS - 2 SP - 102 EP - 112 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Fagan, Andrew J. A1 - Bitz, Andreas A1 - Björkman-Burtscher, Isabella M. A1 - Collins, Christopher M. A1 - Kimbrell, Vera A1 - Raaijmakers, Alexander J. E. T1 - 7T MR Safety JF - Journal of Magnetic Resonance Imaging (JMRI) Y1 - 2021 U6 - http://dx.doi.org/10.1002/jmri.27319 SN - 1522-2586 VL - 53 IS - 2 SP - 333 EP - 346 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - SAR Simulations & Safety JF - NeuroImage Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.neuroimage.2017.03.035 SN - 1053-8119 IS - Epub ahead of print PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus temperature limits JF - Medical Physics Y1 - 2017 U6 - http://dx.doi.org/10.1002/mp.12034 N1 - This article is corrected by: Errata: Erratum: “RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus tissue temperature limits” [Med. Phys. 44(1), 143–157 (2017)] Volume 44, Issue 2, 772 VL - 44 IS - 1 SP - 143 EP - 157 ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Clemens, Markus A1 - Bitz, Andreas T1 - Safety of subjects during radiofrequency exposure in ultra-high-field magnetic resonance imaging JF - IEEE Letters on Electromagnetic Compatibility Practice and Applications N2 - Magnetic resonance imaging (MRI) is one of the most important medical imaging techniques. Since the introduction of MRI in the mid-1980s, there has been a continuous trend toward higher static magnetic fields to obtain i.a. a higher signal-to-noise ratio. The step toward ultra-high-field (UHF) MRI at 7 Tesla and higher, however, creates several challenges regarding the homogeneity of the spin excitation RF transmit field and the RF exposure of the subject. In UHF MRI systems, the wavelength of the RF field is in the range of the diameter of the human body, which can result in inhomogeneous spin excitation and local SAR hotspots. To optimize the homogeneity in a region of interest, UHF MRI systems use parallel transmit systems with multiple transmit antennas and time-dependent modulation of the RF signal in the individual transmit channels. Furthermore, SAR increases with increasing field strength, while the SAR limits remain unchanged. Two different approaches to generate the RF transmit field in UHF systems using antenna arrays close and remote to the body are investigated in this letter. Achievable imaging performance is evaluated compared to typical clinical RF transmit systems at lower field strength. The evaluation has been performed under consideration of RF exposure based on local SAR and tissue temperature. Furthermore, results for thermal dose as an alternative RF exposure metric are presented. Y1 - 2020 SN - 2637-6423 U6 - http://dx.doi.org/10.1109/LEMCPA.2020.3029747 VL - 2 IS - 3 SP - 1 EP - 8 PB - IEEE CY - New York, NY ER -