TY - JOUR A1 - Duong, Minh Tuan A1 - Nguyen, Nhu Huynh A1 - Staat, Manfred T1 - Physical response of hyperelastic models for composite materials and soft tissues JF - Asia pacific journal on computational engineering Y1 - 2015 U6 - https://doi.org/10.1186/s40540-015-0015-x SN - 2196-1166 VL - 2 IS - 3 (December 2015) SP - 1 EP - 18 ER - TY - JOUR A1 - Molinnus, Denise A1 - Bäcker, Matthias A1 - Siegert, Petra A1 - Willenberg, H. A1 - Poghossian, Arshak A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Detection of Adrenaline Based on Substrate Recycling Amplification JF - Procedia Engineering N2 - An amperometric enzyme biosensor has been applied for the detection of adrenaline. The adrenaline biosensor has been prepared by modification of an oxygen electrode with the enzyme laccase that operates at a broad pH range between pH 3.5 to pH 8. The enzyme molecules were immobilized via cross-linking with glutaraldehyde. The sensitivity of the developed adrenaline biosensor in different pH buffer solutions has been studied. Y1 - 2015 U6 - https://doi.org/10.1016/j.proeng.2015.08.708 SN - 1877-7058 N1 - Eurosensors 2015 VL - 120 SP - 540 EP - 543 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Poghossian, Arshak A1 - Schusser, Sebastian A1 - Bäcker, M. A1 - Leinhos, Marcel A1 - Schöning, Michael Josef T1 - Real-time in-situ electrical monitoring of the degradation of biopolymers using semiconductor field-effect devices T2 - Biodegradable biopolymers. Vol. 1 Y1 - 2015 SN - 978-1-63483-632-6 SP - 135 EP - 153 PB - Nova Science Publ. CY - Hauppauge ER - TY - CHAP A1 - Poghossian, Arshak A1 - Bronder, Thomas A1 - Wu, Chunsheng A1 - Schöning, Michael Josef T1 - Label-free sensing of biomolecules by their intrinsic molecular charge using field-effect devices T2 - Semiconductor Micro- and Nanoelectonics : Proceedings of the tenth international conference, Yerevan, Armenia, September 11-13 Y1 - 2015 SN - 978-5-8084-1991-9 SP - 61 EP - 63 ER - TY - JOUR A1 - Schusser, Sebastian A1 - Krischer, Maximillian A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Monitoring of the Enzymatically Catalyzed Degradation of Biodegradable Polymers by Means of Capacitive Field-Effect Sensors JF - Analytical Chemistry N2 - Designing novel or optimizing existing biodegradable polymers for biomedical applications requires numerous tests on the effect of substances on the degradation process. In the present work, polymer-modified electrolyte–insulator–semiconductor (PMEIS) sensors have been applied for monitoring an enzymatically catalyzed degradation of polymers for the first time. The thin films of biodegradable polymer poly(d,l-lactic acid) and enzyme lipase were used as a model system. During degradation, the sensors were read-out by means of impedance spectroscopy. In order to interpret the data obtained from impedance measurements, an electrical equivalent circuit model was developed. In addition, morphological investigations of the polymer surface have been performed by means of in situ atomic force microscopy. The sensor signal change, which reflects the progress of degradation, indicates an accelerated degradation in the presence of the enzyme compared to hydrolysis in neutral pH buffer media. The degradation rate increases with increasing enzyme concentration. The obtained results demonstrate the potential of PMEIS sensors as a very promising tool for in situ and real-time monitoring of degradation of polymers. Y1 - 2015 U6 - https://doi.org/10.1021/acs.analchem.5b00617 SN - 1520-6882 VL - 87 IS - 13 SP - 6607 EP - 6613 PB - ACS Publications CY - Washington, DC ER - TY - JOUR A1 - Beging, Stefan A1 - Leinhos, Marcel A1 - Jablonski, Melanie A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Studying the spatially resolved immobilisation of enzymes on a capacitive field-effect structure by means of nano-spotting JF - Physica status solidi (a) Y1 - 2015 U6 - https://doi.org/10.1002/pssa.201431891 SN - 1862-6319 VL - 212 IS - 6 SP - 1353 EP - 1358 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Reisert, Steffen A1 - Kramer, Friederike A1 - Begoyan, Vardges K. A1 - Buniatyan, Vahe V. A1 - Schöning, Michael Josef T1 - Multi-parameter sensing using high-k oxide of barium strontium titanate JF - Physica status solidi (a) N2 - High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors. In this work, a Si-based sensor chip containing Pt interdigitated electrodes covered with a thin BST layer (485 nm) has been developed for multi-parameter chemical sensing. The chip has been applied for the contactless measurement of the electrolyte conductivity, the detection of adsorbed charged macromolecules (positively charged polyelectrolytes of polyethylenimine) and the concentration of hydrogen peroxide (H2O2) vapor. The experimental results of functional testing of individual sensors are presented. The mechanism of the BST sensitivity to charged polyelectrolytes and H2O2 vapor has been proposed and discussed. Y1 - 2015 U6 - https://doi.org/10.1002/pssa.201431911 SN - 1862-6319 VL - 212 IS - 6 SP - 1259 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Mulhern, Colm A1 - Bialonski, Stephan A1 - Kantz, Holger T1 - Extreme events due to localization of energy JF - Physical Review E Y1 - 2015 U6 - https://doi.org/10.1103/PhysRevE.91.012918 SN - 2470-0053 VL - 91 IS - 1 SP - 012918 ER - TY - JOUR A1 - Bialonski, Stephan A1 - Ansmann, Gerrit A1 - Kantz, Holger T1 - Data-driven prediction and prevention of extreme events in a spatially extended excitable system JF - Physical Review E Y1 - 2015 U6 - https://doi.org/10.1103/PhysRevE.92.042910 SN - 2470-0053 VL - 92 IS - 4 SP - 042910 ER - TY - JOUR A1 - Baringhaus, Ludwig A1 - Gaigall, Daniel T1 - On an independence test approach to the goodness-of-fit problem JF - Journal of Multivariate Analysis N2 - Let X₁,…,Xₙ be independent and identically distributed random variables with distribution F. Assuming that there are measurable functions f:R²→R and g:R²→R characterizing a family F of distributions on the Borel sets of R in the way that the random variables f(X₁,X₂),g(X₁,X₂) are independent, if and only if F∈F, we propose to treat the testing problem H:F∈F,K:F∉F by applying a consistent nonparametric independence test to the bivariate sample variables (f(Xᵢ,Xⱼ),g(Xᵢ,Xⱼ)),1⩽i,j⩽n,i≠j. A parametric bootstrap procedure needed to get critical values is shown to work. The consistency of the test is discussed. The power performance of the procedure is compared with that of the classical tests of Kolmogorov–Smirnov and Cramér–von Mises in the special cases where F is the family of gamma distributions or the family of inverse Gaussian distributions. KW - Goodness-of-fit test KW - Independence test KW - Parametric bootstrap KW - Vapnik–Čhervonenkis class KW - Gamma distribution Y1 - 2015 U6 - https://doi.org/10.1016/j.jmva.2015.05.013 SN - 0047-259X VL - 2015 IS - 140 SP - 193 EP - 208 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Kremers, Alexander A1 - Pieper, Martin T1 - Simulation and Verification of Bionic Heat Exchangers with COMSOL Multiphysics® Software T2 - COMSOL Conference 2015 User Presentations ; COMSOL Conference 2015 Grenoble October 14 - 16, 2015 - World Trade Center, Grenoble, France Y1 - 2015 PB - COMSOL CY - Göttingen ; Berlin ER - TY - JOUR A1 - Bandodkar, Amay J. A1 - Molinnus, Denise A1 - Mirza, Omar A1 - Guinovart, Tomas A1 - Windmiller, Joshua R. A1 - Valdes-Ramirez, Gabriela A1 - Andrade, Francisco J. A1 - Schöning, Michael Josef A1 - Wang, Joseph T1 - Epidermal tattoo potentiometric sodium sensors with wireless signal transduction for continuous non-invasive sweat monitoring JF - Biosensors and bioelectronics N2 - This article describes the fabrication, characterization and application of an epidermal temporary-transfer tattoo-based potentiometric sensor, coupled with a miniaturized wearable wireless transceiver, for real-time monitoring of sodium in the human perspiration. Sodium excreted during perspiration is an excellent marker for electrolyte imbalance and provides valuable information regarding an individual's physical and mental wellbeing. The realization of the new skin-worn non-invasive tattoo-like sensing device has been realized by amalgamating several state-of-the-art thick film, laser printing, solid-state potentiometry, fluidics and wireless technologies. The resulting tattoo-based potentiometric sodium sensor displays a rapid near-Nernstian response with negligible carryover effects, and good resiliency against various mechanical deformations experienced by the human epidermis. On-body testing of the tattoo sensor coupled to a wireless transceiver during exercise activity demonstrated its ability to continuously monitor sweat sodium dynamics. The real-time sweat sodium concentration was transmitted wirelessly via a body-worn transceiver from the sodium tattoo sensor to a notebook while the subjects perspired on a stationary cycle. The favorable analytical performance along with the wearable nature of the wireless transceiver makes the new epidermal potentiometric sensing system attractive for continuous monitoring the sodium dynamics in human perspiration during diverse activities relevant to the healthcare, fitness, military, healthcare and skin-care domains. Y1 - 2014 U6 - https://doi.org/10.1016/j.bios.2013.11.039 SN - 1873-4235 (E-Journal); 0956-5663 (Print) VL - 54 SP - 603 EP - 609 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dikta, Gerhard T1 - Asymptotically efficient estimation under semi-parametric random censorship models JF - Journal of multivariate analysis N2 - We study the estimation of some linear functionals which are based on an unknown lifetime distribution. The observations are assumed to be generated under the semi-parametric random censorship model (SRCM), that is, a random censorship model where the conditional expectation of the censoring indicator given the observation belongs to a parametric family. Under this setup a semi-parametric estimator of the survival function was introduced by the author. If the parametric model assumption is correct, it is known that the estimated functional which is based on this semi-parametric estimator is asymptotically at least as efficient as the corresponding one which rests on the nonparametric Kaplan–Meier estimator. In this paper we show that the estimated functional which is based on this semi-parametric estimator is asymptotically efficient with respect to the class of all regular estimators under this semi-parametric model. Y1 - 2014 U6 - https://doi.org/10.1016/j.jmva.2013.10.002 SN - 1095-7243 (E-Journal); 0047-259X (Print) VL - 124 SP - 10 EP - 24 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Sawada, Kazuaki A1 - Nakazawa, Hirokazu A1 - Takenaga, Shoko A1 - Hizawa, Takeshi A1 - Futagawa, Masato A1 - Dasai, Fumihiro A1 - Sakurai, Takashi A1 - Okumura, Koichi A1 - Hattori, Toshiaki A1 - Ishida, Makoto T1 - Multimodal bioimage sensor JF - IEICE transactions on fundamentals of electronics, communidations and computer sciences N2 - To visualize the biochemical distribution two-dimensionally, we invented a solid-state-type ion image sensor that indicates the chemical activity of solutions and cells. The device, which consists of a CCD array covered with a functionalized membrane to detect charge accumulation, is highly sensitive to changes in the concentration and two-dimensional distribution of ions and biomaterials. Y1 - 2014 U6 - https://doi.org/10.1587/transfun.E97.A.726 SN - 0916-8508 (Print) ; 1745-1337 (Online) VL - E97-A (2014) IS - 3 SP - 726 EP - 733 PB - IEICE CY - Tokyo ER - TY - JOUR A1 - Oberländer, Jan A1 - Kirchner, Patrick A1 - Boyen, Hans-Gerd A1 - Schöning, Michael Josef T1 - Detection of hydrogen peroxide vapor by use of manganese(IV) oxide as catalyst for calorimetric gas sensors JF - Physica status solidi A: Applications and materials science N2 - In this work, the catalyst manganese(IV) oxide (MnO2), of calorimetric gas sensors (to monitor the sterilization agent vaporized hydrogen peroxide) has been investigated in more detail. Chemical analyses by means of X-ray-induced photoelectron spectroscopy have been performed to unravel the surface chemistry prior and after exposure to hydrogen peroxide vapor at elevated temperature, as applied in the sterilization processes of beverage cartons. The surface characterization reveals a change in oxidation states of the metal oxide catalyst after exposure to hydrogen peroxide. Additionally, a cleaning effect of the catalyst, which itself is attached to the sensor surface by means of a polymer interlayer, could be observed. Y1 - 2014 U6 - https://doi.org/10.1002/pssa.201330359 SN - 1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print) VL - 211 IS - 6 SP - 1372 EP - 1376 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Fuest, Matthias A1 - Kotliar, Konstantin A1 - Walter, Peter A1 - Plange, Niklas T1 - Monitoring intraocular pressure changes after intravitreal Ranibizumab injection using rebound tonometry JF - Ophthalmic and physiological optics Y1 - 2014 U6 - https://doi.org/10.1111/opo.12134 SN - 1475-1313 (E-Journal); 0275-5408 (Print) N1 - Special Issue: The Ageing Visual System VL - 34 IS - 4 SP - 438 EP - 444 PB - Wiley-Blackwell CY - Oxford ER - TY - CHAP A1 - Schreiber, Marc A1 - Barkschat, Kai A1 - Kraft, Bodo T1 - Using Continuous Integration to organize and monitor the annotation process of domain specific corpora T2 - 5th International Conference on Information and Communication Systems (ICICS) : 1-3 April 2014, Irbid, Jordanien Y1 - 2014 SN - 978-1-4799-3022-7 U6 - https://doi.org/10.1109/IACS.2014.6841958 SP - 1 EP - 6 ER - TY - JOUR A1 - Riedel, Marc A1 - Kartchemnik, Julia A1 - Schöning, Michael Josef A1 - Lisdat, Fred T1 - Impedimetric DNA detection – steps forward to sensorial application JF - Analytical chemistry N2 - This study describes a label-free impedimetric sensor based on short ssDNA recognition elements for the detection of hybridization events. We concentrate on the elucidation of the influence of target length and recognition sequence position on the sensorial performance. The impedimetric measurements are performed in the presence of the redox system ferri-/ferrocyanide and show an increase in charge transfer resistance upon hybridization of ssDNA to the sensor surface. Investigations on the impedimetric signal stability demonstrate a clear influence of the buffers used during the sensor preparation and the choice of the passivating mercaptoalcanol compound. A stable sensor system has been developed, enabling a reproducible detection of 25mer target DNA in the low nanomolar range. After hybridization, a sensor regeneration can be reached with deionized water by adjustment of effective convection conditions, ensuring a sensor reusability. By investigations of longer targets with overhangs exposed to the solution, we can demonstrate applicability of the impedimetric detection for longer ssDNA. However, a decreasing charge transfer resistance change (ΔRct) is found by extending the overhang. As a strategy to increase the impedance change for longer target strands, the position of the recognition sequence can be designed in a way that a small overhang is exposed to the electrode surface. This is found to result in an increase in the relative Rct change. These results suggest that DNA and consequently negative charge near the electrode possess a larger impact on the impedimetric signal than DNA further away. Y1 - 2014 U6 - https://doi.org/10.1021/ac501800q SN - 1520-6882 (E-Journal); 0003-2700 (Print); 0096-4484 (Print) VL - 86 (2014) IS - 15 SP - 7867 EP - 7874 PB - ACS Publications CY - Columbus ER - TY - JOUR A1 - Guo, Yuanyuan A1 - Seki, Kosuke A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Novel photoexcitation method for light-addressable potentiometric sensor with higher spatial resolution JF - Applied physics express : APEX N2 - A novel photoexcitation method for the light-addressable potentiometric sensor (LAPS) is proposed to achieve a higher spatial resolution of chemical images. The proposed method employs a combined light source that consists of a modulated light probe, which generates the alternating photocurrent signal, and a ring of constant illumination surrounding it. The constant illumination generates a sheath of carriers with increased concentration which suppresses the spread of photocarriers by enhanced recombination. A device simulation was carried out to verify the effect of constant illumination on the spatial resolution, which demonstrated that a higher spatial resolution can be obtained. Y1 - 2014 U6 - https://doi.org/10.7567/APEX.7.067301 SN - 1882-0786 (E-Journa); 1882-0778 (Print) VL - 7 IS - 6 SP - 067301-4 PB - IOP CY - Bristol ER - TY - JOUR A1 - Wagner, Patrick A1 - Doll, Theodor A1 - Schöning, Michael Josef T1 - Engineering of functional interfaces / Patrick Wagner ; Theodor Doll ; Michael J. Schöning (eds.) JF - Physica status solidi (A) : Applications and materials science Y1 - 2014 U6 - https://doi.org/10.1002/pssa.201470241 SN - 1521-396X (E-Book); 1862-6319 (E-Book); 0031-8965 (Print); 1862-6300 (Print) VL - 211 IS - 6 SP - 1339 EP - 1339 PB - Wiley-VCH CY - Weinheim ER -