TY - JOUR A1 - Grajewski, Matthias A1 - Hron, Jaroslav A1 - Turek, Stefan T1 - Numerical analysis for a new non-conforming linear finite element on quadrilaterals JF - Journal of Computational and Applied Mathematics Y1 - 2006 U6 - http://dx.doi.org/10.1016/j.cam.2005.05.024 SN - 0377-0427 VL - 193 IS - 1 SP - 38 EP - 50 ER - TY - JOUR A1 - Bialonski, Stephan A1 - Wellmer, Jörg A1 - Elger, Christian E. A1 - Lehnertz, Klaus T1 - Interictal focus localization in neocortical lesional epilepsies with synchronization cluster analysis JF - Epilepsia Y1 - 2006 SN - 0013-9580 VL - 47 SP - 36 ER - TY - JOUR A1 - Bialonski, Stephan A1 - Lehnertz, Klaus T1 - Identifying phase synchronization clusters in spatially extended dynamical systems JF - Physical Review E Y1 - 2006 U6 - http://dx.doi.org/10.1103/PhysRevE.74.051909 SN - 2470-0053 VL - 74 IS - 5 SP - 051909 ER - TY - JOUR A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios T1 - Influence of the mechanical properties of the muscle-tendon unit on force generation in runners with different running economy JF - Biological Cybernetics Y1 - 2006 U6 - http://dx.doi.org/10.1007/s00422-006-0070-z SN - 1432-0770 VL - 95 IS - 1 SP - 87 EP - 96 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Abouzar, Maryam H. A1 - Ingebrandt, Sven A1 - Platen, Johannes A1 - Offenhäusser, Andreas A1 - Poghossian, Arshak ED - Comini, Elisabetta T1 - Towards label-free detection of charged macromolecules using field-effect-based structures : Scaling down from capacitive EIS sensor over ISFET to nano-scale devices JF - Nanostructured materials and hybrid composites for gas sensors and biomedical applications : symposium held April 18-20, 2006, San Francisco , California, U.S.A. Y1 - 2006 SN - 9781558998711 IS - paper 0915-R05-04 SP - 89 EP - 94 ER - TY - JOUR A1 - Yoshinobu, Tatsuo A1 - Moritz, Werner A1 - Finger, Friedhelm A1 - Schöning, Michael Josef ED - Comini, Elisabetta T1 - Application of thin-film amorphous silicon to chemical imaging JF - Nanostructured materials and hybrid composites for gas sensors and biomedical applications : symposium held April 18-20, 2006, San Francisco , California, U.S.A. Y1 - 2006 SN - 9781558998711 N1 - Materials Research Society symposia proceedings; v. 915 IS - Paper 0910-A-20-01 SP - 1 EP - 10 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - BioFEDs (field-effect devices) : State-of-the-art and new directions JF - Electroanalysis Y1 - 2006 U6 - http://dx.doi.org/10.1002/elan.200603609 SN - 1521-4109 VL - 18 IS - 19-20 SP - 1893 EP - 1900 ER - TY - JOUR A1 - Mosset, J.-B. A1 - Devroede, O. A1 - Krieguer, M. A1 - Rey, M. A1 - Vieira, J.-M. A1 - Jung, J. H. A1 - Kuntner, C. A1 - Streun, M. A1 - Ziemons, Karl A1 - Auffray, E. A1 - Sempere-Roldan, P. A1 - Lecoq, P. A1 - Bruyndonckx, P. A1 - Loude, J.-F. A1 - Tavernier, S. A1 - Morcel, C. T1 - Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator JF - IEEE Transactions on Nuclear Science N2 - This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 1 SP - 25 EP - 29 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Weber, S. A1 - Streun, M. A1 - Parl, C. A1 - Ziemons, Karl T1 - High resolution imaging with ClearPET™ Neuro - first animal images JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance. Y1 - 2006 SN - 1082-3654 SP - 1641 EP - 1644 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - Timemark correction for the ClearPET™ scanners JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented Y1 - 2006 SN - 1082-3654 SP - 2057 EP - 2060 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - The data acquisition system of ClearPET neuro - a small animal PET scanner JF - IEEE Transactions on Nuclear Science N2 - The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jülich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 3 SP - 700 EP - 703 ER - TY - JOUR A1 - Digel, Ilya A1 - Maggakis-Kelemen, Christina A1 - Zerlin, Kay A1 - Linder, Peter T1 - Body temperature-related structural transitions of monotremal and human hemoglobin JF - Biophysical Journal. 91 (2006), H. 8 Y1 - 2006 SN - 1542-0086 SP - 3014 EP - 3021 ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Koshitz, I. N. A1 - Svetlova, O. V. A1 - Zaseeva, M. V. T1 - Physiological principles of hypotensive therapy of open-angle glaucoma during presbyopic period. Part I Initial theoretical presuppositions, hypotheses and facts / Koshitz, I. N. ; Svetlova, O. V. ; Zaseeva, M. V. ; Shuhaev, S. V. ; Makarov, F. N. ; Kotli JF - Glaukoma (2006) Y1 - 2006 N1 - Original in Russisch SP - 35 EP - 53 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Koshitz, I. N. A1 - Svetlowa, O. V. A1 - Zaseeva, M. V. T1 - Physiological principles of hypotensive therapy of open-angle glaucoma during presbyopic period. Part II Promising algorithms of practical sparing applications / Koshitz, I. N. ; Svetlova, O. V. ; Zaseeva, M. V. ; Shuhaev, S. V. ; Makarov, F. N. ; Kotliar JF - Glaukoma (2006) Y1 - 2006 N1 - Original in Russisch SP - 51 EP - 70 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Bauer, S. M. A1 - Zamuraev, L. A. T1 - Model of the transversely isotropic spherical layer for estimation of intraocular pressure changes after intravitreal injections / Bauer, S. M. ; Zamuraev, L. A. ; Kotliar, K. E. JF - Rossiiskii zhurnal biomekhaniki = Russian Journal of biomechanics. 10 (2006), H. 2 Y1 - 2006 SN - 1812-5123 SP - 41 EP - 47 PB - - ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, M. A1 - Arora, D. A1 - Coronado, O. A1 - Pasquali, M. T1 - CFD Analysis of MicroMed Debakey Pump and Hemolysis Prediction / Behbahani, M. ; Behr, M. ; Arora, D. ; Coronado, O. ; Pasquali, M. JF - Artificial Organs. 30 (2006), H. 11 Y1 - 2006 SN - 1525-1594 N1 - Abstracts 14th Congress of the International Society for Rotary Blood Pumps, Leuven, Belgium, August 31–September 2, 2006 ; S7-4 SP - A45 EP - A46 ER - TY - JOUR A1 - Grotendorst, Johannes A1 - Scott, Tony C. A1 - Aubert-Frécon, Monique T1 - New Approach for the Electronic Energies of the Hydrogen Molecular Ion / Scott, Tony C. ; Aubert-Frécon, Monique ; Grotendorst, Johannes JF - Chemical Physics. 324 (2006), H. 2/3 Y1 - 2006 SN - 0301-0104 SP - 323 EP - 338 ER - TY - JOUR A1 - Näther, Niko A1 - Emmerich, Rüdiger A1 - Berger, Jörg A1 - Friedrich, Peter A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schöning, Michael Josef T1 - A novel gas-phase hydrogen peroxide sensor basing on a combined physical/chemical transduction mechanism JF - Nanofunctional materials, nanostructures, and novel devices for biological and chemical detection : November 27 - December 1, 2006, Boston, Massachusetts, USA ; [at the 2006 MRS Fall Meeting]. Y1 - 2006 SN - 978-1-60423-407-7 N1 - Materials Research Society symposium proceedings ; 951 ; MRS fall meeting ; (2006.11.27-12.01 : ; Boston, Mass.) SP - 63 EP - 68 PB - Materials Research Soc. CY - Warrendale, Pa. ER - TY - JOUR A1 - Kaminsky, Radoslav A1 - Kallweit, Stephan A1 - Weber, Hans-Joachim A1 - Simons, Antoine A1 - Kramm, K. A1 - Jazwik, K. A1 - Moll, J. A1 - Verdonck, P. T1 - 3D high speed piv assessment of a new aortic heart valve prototype JF - Journal of biomechanics. 39 (2006), H. Supplement 1 Y1 - 2006 SN - 0021-9290 N1 - World Congress of Biomechanics <5, 2006, München>: Abstracts of the 5th World Congress of Biomechanics SP - S304 EP - S305 PB - - ER - TY - JOUR A1 - Weber, Hans-Joachim A1 - Mo, Xiumei A1 - Ramakrishna, S. T1 - PCL-PGLA composite tubular scaffold preparation and biocompatibility investigation / X. Mo, H.-J. Weber, S. Ramakrishna JF - The International journal of artificial organs. 29 (2006), H. 8 Y1 - 2006 SP - 790 EP - 799 PB - - ER -