TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Dammann, Philipp A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T JF - Medical Physics N2 - Purpose: MRI plays a leading diagnostic role in assessing the musculoskeletal (MSK) system and is well established for most questions at clinically used field strengths (up to 3 T). However, there are still limitations in imaging early stages of cartilage degeneration, very fine tendons and ligaments, or in locating nerve lesions, for example. 7 T MRI of the knee has already received increasing attention in the current published literature, but there is a strong need to develop new radiofrequency (RF) coils to assess more regions of the MSK system. In this work, an eight-channel transmit/receive RF array was built as a multipurpose coil for imaging some of the thus far neglected regions. An extensive coil characterization protocol and first in vivo results of the human wrist, shoulder, elbow, knee, and ankle imaged at 7 T will be presented. Methods: Eight surface loop coils with a dimension ofurn:x-wiley:00942405:media:mp7176:mp7176-math-0001 were machined from FR4 circuit board material. To facilitate easy positioning, two coil clusters, each with four loop elements, were combined to one RF transmit/receive array. An overlapped and shifted arrangement of the coil elements was chosen to reduce the mutual inductance between neighboring coils. A phantom made of body-simulating liquid was used for tuning and matching on the bench. Afterward, the S-parameters were verified on a human wrist, elbow, and shoulder. For safety validation, a detailed compliance test was performed including full wave simulations of the RF field distribution and the corresponding specific absorption rate (SAR) for all joints. In vivo images of four volunteers were assessed with gradient echo and spin echo sequences modified to obtain optimal image contrast, full anatomic coverage, and the highest spatial resolution within a reasonable acquisition time. The performance of the RF coil was additionally evaluated by in vivo B1 mapping. Results: A comparison of B1 per unit power, flip angle distribution, and anatomic images showed a fairly homogeneous excitation for the smaller joints (elbow, wrist, and ankle), while for the larger joints, the shoulder and especially the knee, B1 inhomogeneities and limited penetration depth were more pronounced. However, the greater part of the shoulder joint could be imaged.In vivo images rendered very fine anatomic details such as fascicles of the median nerve and the branching of the nerve bundles. High-resolution images of cartilage, labrum, and tendons could be acquired. Additionally, turbo spin echo (TSE) and inversion recovery sequences performed very well. Conclusions: This study demonstrates that the concept of two four-channel transmit/receive RF arrays can be used as a multipurpose coil for high-resolutionin vivo MR imaging of the musculoskeletal system at 7 T. Not only gradient echo but also typical clinical and SAR-intensive sequences such as STIR and TSE performed well. Imaging of small structures and peripheral nerves could in particular benefit from this technique. Y1 - 2010 U6 - https://doi.org/10.1118/1.3517176 SN - 2473-4209 VL - 37 IS - 12 SP - 6368 EP - 6376 PB - Wiley CY - Hoboken, NJ ER - TY - JOUR A1 - Schlamann, Marc A1 - Voigt, Melanie A. A1 - Maderwald, Stefan A1 - Bitz, Andreas A1 - Kraff, Oliver A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Forsting, Michael A1 - Wilhelm, Hans T1 - Exposure to high-field MRI does not affect cognitive function JF - Journal of Magnetic Resonance Imaging N2 - Purpose To assess potential cognitive deficits under the influence of static magnetic fields at various field strengths some studies already exist. These studies were not focused on attention as the most vulnerable cognitive function. Additionally, mostly no magnetic resonance imaging (MRI) sequences were performed. Materials and Methods In all, 25 right-handed men were enrolled in this study. All subjects underwent one MRI examination of 63 minutes at 1.5 T and one at 7 T within an interval of 10 to 30 days. The order of the examinations was randomized. Subjects were referred to six standardized neuropsychological tests strictly focused on attention immediately before and after each MRI examination. Differences in neuropsychological variables between the timepoints before and after each MRI examination were assessed and P-values were calculated Results Only six subtests revealed significant differences between pre- and post-MRI. In these tests the subjects achieved better results in post-MRI testing than in pre-MRI testing (P = 0.013–0.032). The other tests revealed no significant results. Conclusion The improvement in post-MRI testing is only explicable as a result of learning effects. MRI examinations, even in ultrahigh-field scanners, do not seem to have any persisting influence on the attention networks of human cognition immediately after exposure. Y1 - 2010 U6 - https://doi.org/10.1002/jmri.22065 SN - 1522-2586 VL - 31 IS - 5 SP - 1061 EP - 1066 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Schlamann, Marc A1 - Yoon, Min-Suk A1 - Maderwald, Stefan A1 - Pietrzyk, Thomas A1 - Bitz, Andreas A1 - Gerwig, Marcus A1 - Forsting, Michael A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Kastrup, Oliver T1 - Short term effects of magnetic resonance imaging on excitability of the motor cortex at 1.5T and 7T JF - Academic Radiology N2 - Rationale and Objectives The increasing spread of high-field and ultra-high-field magnetic resonance imaging (MRI) scanners has encouraged new discussion of the safety aspects of MRI. Few studies have been published on possible cognitive effects of MRI examinations. The aim of this study was to examine whether changes are measurable after MRI examinations at 1.5 and 7 T by means of transcranial magnetic stimulation (TMS). Materials and Methods TMS was performed in 12 healthy, right-handed male volunteers. First the individual motor threshold was specified, and then the cortical silent period (SP) was measured. Subsequently, the volunteers were exposed to the 1.5-T MRI scanner for 63 minutes using standard sequences. The MRI examination was immediately followed by another TMS session. Fifteen minutes later, TMS was repeated. Four weeks later, the complete setting was repeated using a 7-T scanner. Control conditions included lying in the 1.5-T scanner for 63 minutes without scanning and lying in a separate room for 63 minutes. TMS was performed in the same way in each case. For statistical analysis, Wilcoxon's rank test was performed. Results Immediately after MRI exposure, the SP was highly significantly prolonged in all 12 subjects at 1.5 and 7 T. The motor threshold was significantly increased. Fifteen minutes after the examination, the measured value tended toward normal again. Control conditions revealed no significant differences. Conclusion MRI examinations lead to a transient and highly significant alteration in cortical excitability. This effect does not seem to depend on the strength of the static magnetic field. Y1 - 2010 U6 - https://doi.org/10.1016/j.acra.2009.10.004 SN - 1076-6332 VL - 17 IS - 3 SP - 277 EP - 281 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Abel, Thomas A1 - Bonin, Dominik A1 - Albracht, Kirsten A1 - Zeller, Sebastian A1 - Brüggemann, Gert-Peter A1 - Burkett, Brendan A1 - Strüder, Heiko K. T1 - Kinematic profile of the elite handcyclist T2 - 28th International Conference on Biomechanics in Sports, Marquette, Michigan, USA, July 19 – 23, 2010 Y1 - 2017 SN - 1999-4168 SP - 140 EP - 141 ER - TY - THES A1 - Albracht, Kirsten T1 - Influence of mechanical properties of the leg extensor muscletendon units on running economy Y1 - 2010 N1 - Cologne, German Sport Univ., Diss., 2010 PB - Deutsche Sporthochschule Köln CY - Köln ER - TY - JOUR A1 - Kroll-Ludwigs, Kathrin T1 - Die Zukunft des verbraucherschützenden Widerrufsrechts in Europa JF - Zeitschrift für europäisches Privatrecht : ZEuP N2 - Das verbraucherschützende Widerrufsrecht ist in die Jahre gekommen. Als Ergebnis der zunehmenden Rechtszersplitterung im europäischen Richtlinienrecht hat sich eine unüberschaubare Bandbreite an Ausgestaltungsformen in den mitgliedstaatlichen Rechtssystemen herausgebildet. Effektivitätseinbußen, Wettbewerbsverzerrungen und ein hohes Maß an Rechtsunsicherheit sind die Folgen. Zurückführen lässt sich die kostenintensive Fragmentierung des Verbrauchervertragsrechts auf die bisherige Regelungspolitik der Mindestharmonisierung, die es den Mitgliedstaaten erlaubt, von dem durch die Richtlinien gesetzten Mindeststandard durch „überschießende Umsetzung” abzuweichen. Der Unionsgesetzgeber versucht dem vermehrt durch einen Prozess der Vollharmonisierung zu begegnen: Neben Reformen der Richtlinie über Verbraucherkredite (VerbrKrRL) sowie der Timesharing-Richtlinie (TimesharingRL), liegt seit dem 8. Oktober 2008 nunmehr auch der Entwurf einer Rahmenrichtlinie über die Rechte der Verbraucher (VRRL-E) vor. Danach sollen die bisherigen Richtlinien über Haustürgeschäfte (HaustürgeschäfteRL), Fernabsatzverträge (FARL), missbräuchliche Klauseln sowie Verbrauchsgüterkäufe vereinigt werden. Für das verbraucherschützende Widerrufsrecht ist damit zum einen die Herausbildung einheitlicher Kernelemente verbunden, zum anderen tritt es in Konkurrenz zu umfassenden Informationspflichten, die ebenfalls den Schutz des Verbrauchers vor dem unüberlegten Abschluss riskanter bzw. nachteiliger Verträge zum Ziel haben. Angesichts dieser Entwicklung stellt sich im Folgenden die Frage nach der Zukunft des unionsrechtlichen Widerrufsrechts. Von besonderer Bedeutung ist dabei die Klärung des Verhältnisses zu den verbraucherschützenden Informationspflichten. Dazu bedarf es zunächst der Herausarbeitung einheitlicher Kernelemente des Widerrufsrechts im vollharmonisierten Richtlinienrecht (II.) sowie einer Systematisierung der sekundärrechtlichen Informationspflichten im Anschluss eine kritische Gegenüberstellung der Vor- und Nachteile beider Schutzinstrumente erfolgen kann (IV.). Y1 - 2010 SN - 0943-3929 VL - 18 IS - 3 SP - 509 EP - 534 PB - Beck CY - München ER - TY - JOUR A1 - Nabil, F. A1 - Peterson, Leif Arne A1 - Schmidt, A. A1 - Geerdes, D. T1 - Die Holzkuppel des Neuen Palais in Potsdam JF - Bauingenieur Y1 - 2010 SN - 0005-6650 VL - 85 IS - 8 SP - 324 EP - 330 PB - Springer-VDI-Verlag CY - Düsseldorf ER - TY - JOUR A1 - Degering, Christian A1 - Eggert, Thorsten A1 - Puls, Michael A1 - Bongaerts, Johannes A1 - Evers, Stefan A1 - Maurer, Karl-Heinz A1 - Jaeger, Karl-Erich T1 - Optimization of protease secretion in Bacillus subtilis and Bacillus licheniformis by screening of homologous and herologous signal peptides JF - Applied and environmental microbiology N2 - Bacillus subtilis and Bacillus licheniformis are widely used for the large-scale industrial production of proteins. These strains can efficiently secrete proteins into the culture medium using the general secretion (Sec) pathway. A characteristic feature of all secreted proteins is their N-terminal signal peptides, which are recognized by the secretion machinery. Here, we have studied the production of an industrially important secreted protease, namely, subtilisin BPN′ from Bacillus amyloliquefaciens. One hundred seventy-three signal peptides originating from B. subtilis and 220 signal peptides from the B. licheniformis type strain were fused to this secretion target and expressed in B. subtilis, and the resulting library was analyzed by high-throughput screening for extracellular proteolytic activity. We have identified a number of signal peptides originating from both organisms which produced significantly increased yield of the secreted protease. Interestingly, we observed that levels of extracellular protease were improved not only in B. subtilis, which was used as the screening host, but also in two different B. licheniformis strains. To date, it is impossible to predict which signal peptide will result in better secretion and thus an improved yield of a given extracellular target protein. Our data show that screening a library consisting of homologous and heterologous signal peptides fused to a target protein can identify more-effective signal peptides, resulting in improved protein export not only in the original screening host but also in different production strains. Y1 - 2010 U6 - https://doi.org/10.1128/AEM.01146-10 SN - 1098-5336 (E-Journal); 0003-6919 (Print); 0099-2240 (Print) VL - 76 IS - 19 SP - 6370 EP - 6378 PB - American Society for Microbiology CY - Washington, DC ER - TY - CHAP A1 - Reimer, Lars A1 - Braun, Carsten A1 - Wellmer, Georg A1 - Behr, Marek A1 - Ballmann, Josef T1 - Development of a modular method for computational aero-structural analysis of aircraft T2 - Summary of flow modulation and fluid-structure interaction findings. Results of the Collaborative Research Center SFB 401 at the RWTH Aachen University, Aachen, Germany, 1997-2008 / ed.: Wolfgang Schröder. Notes on numerical fluid mechanics and multidisciplinary design. Vol. 109 Y1 - 2010 SN - 978-3-642-04087-0 SP - 205 EP - 238 PB - Springer CY - Berlin ER - TY - CHAP A1 - Elsen, Ingo A1 - Hawari, Asma A1 - Johnen, Uwe ED - Pietsch, Wolfram ED - Krams, Benedikt T1 - Produktkernel in der Systemintegration (Erfahrungsbericht aus der Praxis) T2 - Vom Projekt zum Produkt - Fachtagung des GI-Fachausschusses Management der Anwendungsentwicklung und -wartung im Fachbereich Wirtschaftsinformatik (WI-MAW), 1. - 3. Dezember 2010 in Aachen N2 - In der Vergangenheit basierten große Systemintegrationsprojekte in der Regel auf Individualentwicklungen für einzelne Kunden. Getrieben durch Kostendruck steigt aber der Bedarf nach standardisierten Lösungen, die gleichzeitig die individuellen Anforderungen des jeweiligen Umfelds berücksichtigen. T-Systems GEI GmbH wird beiden Anforderungen mit Produktkerneln gerecht. Neben den technischen Aspekten der Kernelentwicklung spielen besonders organisatorische Aspekte eine Rolle, um Kernel effizient und qualitativ hochwertig zu entwickeln, ohne deren Funktionalitäten ins Uferlose wachsen zu lassen. Umgesetzt hat T-Systems dieses Konzept für Flughafeninformationssysteme. Damit kann dem wachsenden Bedarf der Flughafenbetreiber nach einer effizienten und kostengünstigen Softwarelösung zur Unterstützung Ihrer Geschäftsprozesse entsprochen werden. Y1 - 2010 SN - 9783885792727 SN - 1617-5468 SP - 93 EP - 102 PB - Gesellschaft für Informatik eV CY - Bonn ER - TY - CHAP A1 - Park, Jin A1 - Butenweg, Christoph A1 - Reindl, Lukas T1 - Untersuchung der Eignung von Ankerschienensystemen unter Erdbebeneinwirkungen T2 - Conference proceedings / ANSYS Conference & 28th CADFEM Users´ Meeting 2010 : 3. - 5. November 2010, Eurogess Aachen / CADFEM; ANSYS Y1 - 2010 SN - 3-937523-07-3 SP - Dokument 2.11.1 PB - CADFEM [u.a.] CY - Grafing ER - TY - CHAP A1 - Meskouris, Konstantin A1 - Gellert, Christoph A1 - Butenweg, Christoph T1 - Neuer Ansatz für die Bemessung von Mauerwerksbauten T2 - Innovationen im konstruktiven Ingenieurbau : Methoden - Materialien - Bauwerke ; Festschrift Professor Hirschfeld / hrsg. von Karl Beucke Y1 - 2010 SP - 217 EP - 224 PB - Bauhaus-Univ. Weimar CY - Weimar ER - TY - CHAP A1 - Butenweg, Christoph A1 - Gellert, Christoph A1 - Meyer, Udo T1 - Erdbebenbemessung bei Mauerwerksbauten T2 - Mauerwerk-Kalender 2010: Normen für Bemessung und Ausführung Y1 - 2010 SN - 3-433-60040-6 ; 978-3-433-60040-5 U6 - https://doi.org/10.1002/9783433600405.ch7 SP - 141 EP - 167 PB - Ernst & Sohn CY - Berlin ER - TY - PAT A1 - O'Connell, Timothy A1 - Siegert, Petra A1 - Evers, Stefan A1 - Bongaerts, Johannes A1 - Weber, Thomas A1 - Maurer, Karl-Heinz A1 - Bessler, Cornelius T1 - Wasch- oder Reinigungsmittel mit gesteigerter Waschkraft [Offenlegungsschrift] T1 - Method from improving the cleaning action of a detergent of cleaning agent [US Patentanmeldung] Y1 - 2010 SP - 1 EP - 34 PB - Deutsches Patentamt CY - München ER - TY - CHAP A1 - Heinz, G. A1 - Oertel, Mario A1 - Bung, Daniel Bernhard ED - Janssen, Robert T1 - Investigations on a cooling water system for a gas tubine facility concerning air vortexes and sediment transport T2 - Hydraulic structures: useful water harvesting systems or relics? : Third International Junior Researcher and Engineer Workshop on Hydraulic Structures (IJREWHS'10) : Edinburgh, Scotland, U.K., 2-3 May 2010 Y1 - 2010 SN - 9781742720159 SP - 109 EP - 116 PB - School of Civil Engineering, The University of Queensland CY - Brisbane ER - TY - CHAP A1 - Dachwald, Bernd T1 - Solar sail dynamics and control T2 - Encyclopedia of Aerospace Engineering N2 - Solar sails are large and lightweight reflective structures that are propelled by solar radiation pressure. This chapter covers their orbital and attitude dynamics and control. First, the advantages and limitations of solar sails are discussed and their history and development status is outlined. Because the dynamics of solar sails is governed by the (thermo-)optical properties of the sail film, the basic solar radiation pressure force models have to be described and compared before parameters to measure solar sail performance can be defined. The next part covers the orbital dynamics of solar sails for heliocentric motion, planetocentric motion, and motion at Lagrangian equilibrium points. Afterwards, some advanced solar radiation pressure force models are described, which allow to quantify the thrust force on solar sails of arbitrary shape, the effects of temperature, of light incidence angle, of surface roughness, and the effects of optical degradation of the sail film in the space environment. The orbital motion of a solar sail is strongly coupled to its rotational motion, so that the attitude control of these soft and flexible structures is very challenging, especially for planetocentric orbits that require fast attitude maneuvers. Finally, some potential attitude control methods are sketched and selection criteria are given. KW - solar sail KW - sailcraft KW - orbital dynamics KW - orbit control KW - attitude dynamics Y1 - 2010 U6 - https://doi.org/10.1002/9780470686652.eae292 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Zhubanova, Azhar A. A1 - Aknazarov, S. K. A1 - Mansurov, Zulkhair A1 - Digel, Ilya A1 - Kozhalakova, A. A. A1 - Akimbekov, Nuraly S. A1 - O'Heras, Carlos A1 - Tazhibayeva, S. A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - Adsorption of bacterial Lipopolysaccharides and blood plasma proteins on modified carbonized materials N2 - Bacterial lipopolysaccharides (endotoxins) show strong biological effects at very low concentrations in human beings and many animals when entering the blood stream. These include affecting structure and function of organs and cells, changing metabolic functions, raising body temperature, triggering the coagulation cascade, modifying hemodynamics and causing septic shock. Because of this toxicity, the removal of even minute amounts is essential for safe parenteral administration of drugs and also for septic shock patients' care. The absence of a general method for endotoxin removal from liquid interfaces urgently requires finding new methods and materials to overcome this gap. Nanostructured carbonized plant parts is a promising material that showed good adsorption properties due to its vast pore network and high surface area. The aim of this study was comparative measurement of endotoxin- and blood proteins-related adsorption rate and adsorption capacity for different carboneous materials produced at different temperatures and under different surface modifications. As a main surface modificator, positively cbarged polymer, polyethileneimine (PEl) was used. Activated carbon materials showed good adsorption properties for LPS and some proteins used in the experiments. During the batch experiments, several techniques (dust removal, autoclaving) were used and optimized for improving the material's adsorption behavior. Also, with the results obtained it was possible to differentiate the materials according to their adsorption capacity and kinetic characteristics. Modification of the surface apparently has not affected hemoglobin binding to the adsorbent's surface. Obtained adsorption isotherms can be used as a powerful tool for designing of future column-based setups for blood purification from LPS, which is especially important for septic shock treatment. KW - Kohlenstofffaser KW - Lipopolysaccharide KW - nanostrukturierte carbonisierte Pflanzenteile KW - lipopolysaccharides KW - nanostructured carbonized plant parts Y1 - 2010 ER - TY - RPRT A1 - Lanz, Marco A1 - Fricke, Barbara A1 - Anthrakidis, Anette A1 - Genter, Mirjam A1 - Hoffschmidt, Bernhard A1 - Faber, Christian A1 - Hauser, Eva A1 - Klann, Uwe A1 - Leprich, Uwe A1 - Bauknecht, Dierk A1 - Koch, Matthias A1 - Peter, Stefan T1 - CO2-Emissionsminderung durch Ausbau, informationstechnische Vernetzung und Netzoptimierung von Anlagen dezentraler, fluktuierender und erneuerbarer Energieerzeugung in Deutschland : Endbericht zum Vorhaben ; Kurzbezeichnung: CO2DEZ. Forschungsbericht / Umweltbundesamt. Bd. 1550. Förderkennzeichen: UFOPLAN 3707 46 100 Y1 - 2010 ER - TY - CHAP A1 - Kapoor, Hrshi A1 - Braun, Carsten A1 - Boller, Christian ED - Casciati, Fabio T1 - Modelling and optimisation of maintenance intervals to realize structural health monitoring applications on aircraft T2 - Structural health monitoring 2010 : proceedings of the Fifth European Workshop on Structural Health Monitoring held at Sorrento, Naples, Italy, June 28 - July 4, 2010 ; [EWSHM] Y1 - 2010 SN - 978-1-60595-024-2 SP - 55 EP - 63 PB - DEStech Publ. CY - Lancaster, Pa. ER - TY - JOUR A1 - Ferrein, Alexander T1 - golog.lua: Towards a Non-Prolog Implementation of Golog for Embedded Systems Y1 - 2010 SP - 20 EP - 28 ER -