TY - JOUR A1 - Engel, Mareike A1 - Gemünde, Andre A1 - Holtmann, Dirk A1 - Müller-Renno, Christine A1 - Ziegler, Christiane A1 - Tippkötter, Nils A1 - Ulber, Roland T1 - Clostridium acetobutylicum’s connecting world: cell appendage formation in bioelectrochemical systems JF - ChemElectroChem N2 - Bacterial cell appendix formation supports cell-cell interaction, cell adhesion and cell movement. Additionally, in bioelectrochemical systems (BES), cell appendages have been shown to participate in extracellular electron transfer. In this work, the cell appendix formation of Clostridium acetobutylicum in biofilms of a BES are imaged and compared with conventional biofilms. Under all observed conditions, the cells possess filamentous appendages with a higher number and density in the BES. Differences in the amount of extracellular polymeric substance in the biofilms of the electrodes lead to the conclusion that the cathode can be used as electron donor and the anode as electron acceptor by C. acetobutylicum. When using conductive atomic force microscopy, a current response of about 15 nA is found for the cell appendages from the BES. This is the first report of conductivity for clostridial cell appendices and represents the basis for further studies on their role for biofilm formation and electron transfer. Y1 - 2019 U6 - https://doi.org/10.1002/celc.201901656 SN - 2196-0216 VL - 7 IS - 2 SP - 414 EP - 420 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Karschuck, T. L. A1 - Filipov, Y. A1 - Bollella, P. A1 - Schöning, Michael Josef A1 - Katz, E. T1 - Not-XOR (NXOR) logic gate based on an enzyme-catalyzed reaction JF - International Journal of Unconventional Computing N2 - Enzyme-catalyzed reactions have been designed to mimic various Boolean logic gates in the general framework of unconventional biomolecular computing. While some of the logic gates, particularly OR, AND, are easy to realize with biocatalytic reactions and have been reported in numerous publications, some other, like NXOR, are very challenging and have not been realized yet with enzyme reactions. The paper reports on a novel approach to mimicking the NXOR logic gate using the bell-shaped enzyme activity dependent on pH values. Shifting pH from the optimum value to the acidic or basic values by using acid or base inputs (meaning 1,0 and 0,1 inputs) inhibits the enzyme reaction, while keeping the optimum pH (assuming 0,0 and 1,1 input combinations) preserves a high enzyme activity. The challenging part of the present approach is the selection of an enzyme with a well-demonstrated bell-shape activity dependence on the pH value. While many enzymes can satisfy this condition, we selected pyrroloquinoline quinone (PQQ)-dependent glucose dehydrogenase as this enzyme has the optimum pH center-located on the pH scale allowing the enzyme activity change by the acidic and basic pH shift from the optimum value corresponding to the highest activity. The present NXOR gate is added to the biomolecular “toolbox” as a new example of Boolean logic gates based on enzyme reactions. Y1 - 2019 SN - 1548-7199 VL - 14 IS - 3-4 SP - 235 EP - 242 PB - Old City Publishing CY - Philadelphia ER - TY - JOUR A1 - Dantism, Shahriar A1 - Röhlen, Desiree A1 - Wagner, Torsten A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - A LAPS-based differential sensor for parallelized metabolism monitoring of various bacteria JF - Sensors N2 - Monitoring the cellular metabolism of bacteria in (bio)fermentation processes is crucial to control and steer them, and to prevent undesired disturbances linked to metabolically inactive microorganisms. In this context, cell-based biosensors can play an important role to improve the quality and increase the yield of such processes. This work describes the simultaneous analysis of the metabolic behavior of three different types of bacteria by means of a differential light-addressable potentiometric sensor (LAPS) set-up. The study includes Lactobacillus brevis, Corynebacterium glutamicum, and Escherichia coli, which are often applied in fermentation processes in bioreactors. Differential measurements were carried out to compensate undesirable influences such as sensor signal drift, and pH value variation during the measurements. Furthermore, calibration curves of the cellular metabolism were established as a function of the glucose concentration or cell number variation with all three model microorganisms. In this context, simultaneous (bio)sensing with the multi-organism LAPS-based set-up can open new possibilities for a cost-effective, rapid detection of the extracellular acidification of bacteria on a single sensor chip. It can be applied to evaluate the metabolic response of bacteria populations in a (bio)fermentation process, for instance, in the biogas fermentation process. Y1 - 2019 U6 - https://doi.org/10.3390/s19214692 SN - 1424-8220 VL - 19 IS - 21 PB - MDPI CY - Basel ER - TY - CHAP A1 - Alhwarin, Faraj A1 - Schiffer, Stefan A1 - Ferrein, Alexander A1 - Scholl, Ingrid T1 - An Optimized Method for 3D Body Scanning Applications Based on KinectFusion T2 - Communications in Computer and Information Science Y1 - 2019 U6 - https://doi.org/10.1007/978-3-030-29196-9_6 SN - 1865-0929 N1 - 11th International Joint Conference on Biomedical Engineering Systems and Technologies, BIOSTEC 2018; Funchal; Portugal; 19 January 2018 through 21 January 2018 VL - 1024 SP - 100 EP - 113 PB - Springer ER - TY - CHAP A1 - Sattler, Johannes Christoph A1 - Alexopoulos, Spiros A1 - Chico Caminos, Ricardo Alexander A1 - Mitchell, John C. A1 - Ruiz, Victor C. A1 - Kalogirou, Soteris A1 - Ktistis, Panayiotis K. A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Dynamic simulation model of a parabolic trough collector system with concrete thermal energy storage for process steam generation T2 - AIP Conference Proceedings Y1 - 2019 U6 - https://doi.org/10.1063/1.5117663 SN - 0094243X VL - 2126 SP - 150007-1 EP - 150007-8 ER - TY - CHAP A1 - May, Martin A1 - Breitbach, Gerd A1 - Alexopoulos, Spiros A1 - Latzke, Markus A1 - Bäumer, Klaus A1 - Uhlig, Ralf A1 - Söhn, Matthias A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Experimental facility for investigations of wire mesh absorbers for pressurized gases T2 - AIP Conference Proceedings Y1 - 2019 U6 - https://doi.org/10.1063/1.5117547 SN - 0094243X VL - 2126 SP - 030035-1 EP - 030035-9 ER - TY - CHAP A1 - Mahdi, Zahra A1 - Rendón, Carlos A1 - Schwager, Christian A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Novel concept for indirect solar-heated methane reforming T2 - AIP Conference Proceedings Y1 - 2019 U6 - https://doi.org/10.1063/1.5117694 SN - 0094-243X VL - 2126 SP - 180014-1 EP - 180014-7 PB - AIP Publishing CY - Melville, NY ER - TY - CHAP A1 - Breitbach, Gerd A1 - Alexopoulos, Spiros A1 - May, Martin A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Analysis of volumetric solar radiation absorbers made of wire meshes T2 - AIP Conference Proceedings Y1 - 2019 U6 - https://doi.org/10.1063/1.5117521 SN - 0094243X VL - 2126 SP - 030009-1 EP - 030009-6 ER - TY - CHAP A1 - Hüning, Felix T1 - Complexity for heterogeneous classes: teaching embedded systems using an open project approach T2 - Varietas delectat: Complexity is the new normality - 47th Annual Conference, Budapest, Hungary16th - 20th September 2019. SEFI 47th Annual Conference Proceedings Y1 - 2019 SN - 978-2-87352-018-2 SP - 540 EP - 549 ER - TY - JOUR A1 - Schael, S. A1 - Atanasyan, A. A1 - Berdugo, J. A1 - Bretz, T. A1 - Czupalla, Markus A1 - Dachwald, Bernd A1 - Doetinchem, P. von A1 - Duranti, M. A1 - Gast, H. A1 - Karpinski, W. A1 - Kirn, T. A1 - Lübelsmeyer, K. A1 - Maña, C. A1 - Marrocchesi, P.S. A1 - Mertsch, P. A1 - Moskalenko, I.V. A1 - Schervan, T. A1 - Schluse, M. A1 - Schröder, K.-U. A1 - Schultz von Dratzig, A. A1 - Senatore, C. A1 - Spies, L. A1 - Wakely, S.P. A1 - Wlochal, M. A1 - Uglietti, D. A1 - Zimmermann, J. T1 - AMS-100: The next generation magnetic spectrometer in space – An international science platform for physics and astrophysics at Lagrange point 2 JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment Y1 - 2019 U6 - https://doi.org/10.1016/j.nima.2019.162561 SN - 0168-9002 VL - 944 IS - 162561 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Arreola, Julio A1 - Keusgen, Michael A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Combined calorimetric gas- and spore-based biosensor array for online monitoring and sterility assurance of gaseous hydrogen peroxide in aseptic filling machines JF - Biosensors and Bioelectronics Y1 - 2019 U6 - https://doi.org/10.1016/j.bios.2019.111628 SN - 0956-5663 VL - 143 IS - 111628 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Mennicken, Max A1 - Peter, Sophia Katharina A1 - Kaulen, Corinna A1 - Simon, Ulrich A1 - Karthäuser, Silvia T1 - Controlling the Electronic Contact at the Terpyridine/Metal Interface JF - The Journal of Physical Chemistry C Y1 - 2019 U6 - https://doi.org/10.1021/acs.jpcc.9b05865 SN - 1932-7455 VL - 123 IS - 35 SP - 21367 EP - 21375 ER - TY - JOUR A1 - Savitskaya, I.S. A1 - Kistaubayeva, A.S. A1 - Ignatova, L.V. A1 - Digel, Ilya T1 - Antimicrobial and wound healing properties of a bacterial cellulose based material containing B. subtilis cells JF - Heliyon Y1 - 2019 U6 - https://doi.org/10.1016/j.heliyon.2019.e02592 SN - 2405-8440 VL - 5 IS - 10 SP - Artikelnummer e02592 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Delaittre, Guillaume T1 - Telechelic Poly(2-Oxazoline)s JF - European Polymer Journal Y1 - 2019 U6 - https://doi.org/10.1016/j.eurpolymj.2019.109281 SN - 0014-3057 IS - In Press, Journal Pre-proof, 109281 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Linder, Peter A1 - Beckler, Matthias A1 - Doerr, Leo A1 - Stoelzle-Feix, Sonja A1 - Fertig, Niels A1 - Jung, Alexander A1 - Staat, Manfred A1 - Gossmann, Matthias T1 - A new in vitro tool to investigate cardiac contractility under physiological mechanical conditions JF - Journal of Pharmacological and Toxicological Methods Y1 - 2019 U6 - https://doi.org/10.1016/j.vascn.2019.05.162 SN - 1056-8719 VL - 99 IS - Article number 106595 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schieren, Mark A1 - Kleinschmidt, Joris A1 - Schmutz, Axel A1 - Loop, Torsten A1 - Gatzweiler, Karl-Heinz A1 - Staat, Manfred A1 - Wappler, Frank A1 - Defosse, Jerome T1 - Comparison of forces acting on maxillary incisors during tracheal intubation with different laryngoscopy techniques: a blinded manikin study JF - Anaesthesia Y1 - 2019 SN - 1365-2044 U6 - https://doi.org/10.1111/anae.14815 N1 - Die Anhänge "Table S1 (Impact of sex and level of training on dental force. Results presented as median (IQR [range]) and n (%))" und "Appendix S1 (Measurement technique.)" stehen unter "Supporting Information" zum Download bereit. VL - 74 IS - 12 PB - Wiley-Blackwell CY - Oxford ER - TY - CHAP A1 - Rao, Deepak A1 - Pathrose, Plato A1 - Hüning, Felix A1 - Sid, Jithin T1 - An Approach for Validating Safety of Perception Software in Autonomous Driving Systems T2 - Model-Based Safety and Assessment: 6th International Symposium, IMBSA 2019, Thessaloniki, Greece, October 16–18, 2019, Proceedings N2 - The increasing complexity of Advanced Driver Assistance Systems (ADAS) presents a challenging task to validate safe and reliable performance of these systems under varied conditions. The test and validation of ADAS/AD with real test drives, although important, involves huge costs and time. Simulation tools provide an alternative with the added advantage of reproducibility but often use ideal sensors, which do not reflect real sensor output accurately. This paper presents a new validation methodology using fault injection, as recommended by the ISO 26262 standard, to test software and system robustness. In our work, we investigated and developed a tool capable of inserting faults at different software and system levels to verify its robustness. The scope of this paper is to cover the fault injection test for the Visteon’s DriveCore™ system, a centralized domain controller for Autonomous driving which is sensor agnostic and SoC agnostic. With this new approach, the validation of safety monitoring functionality and its behavior can be tested using real-world data instead of synthetic data from simulation tools resulting in having better confidence in system performance before proceeding with in-vehicle testing. KW - Advanced driver assistance systems (ADAS/AD) KW - ISO 26262 KW - Safety-critical systems validation KW - Safety of the intended functionality (SOTIF) Y1 - 2019 SN - 978-3-030-32872-6 U6 - https://doi.org/10.1007/978-3-030-32872-6_20 SP - 303 EP - 316 PB - Springer CY - Cham ER - TY - JOUR A1 - Panc, Nicolae A1 - Contiu, Glad A1 - Bocanet, Vlad A1 - Thurn, Laura A1 - Sabau, Emilia T1 - The influence of cutting technology on surface wear hardness JF - Academic Journal of Manufacturing Engineering Y1 - 2019 SN - 1583-7904 VL - 17 IS - 3 SP - 205 EP - 210 ER - TY - CHAP A1 - Ernhardt, Selina A1 - Drumm, Christian A1 - van Gog, Tamara A1 - Brand-Gruwel, Saskia A1 - Jarodzka, Halszka T1 - Through the eyes of a programmer : a research project on how to foster programming education with eye-tracking technology T2 - Tagungsband zur 32. AKWI-Jahrestagung vom 15.09.2019 bis 18.09.2019 an der Fachhochschule für Angewandte Wissenschaften Aachen Y1 - 2019 SN - 978-3-944330-62-4 SP - 42 EP - 47 PB - Mana-Buch CY - Heide ER - TY - CHAP A1 - Götten, Falk A1 - Finger, Felix T1 - Conceptual Design of a Modular 150 kg Vertical Take-off and Landing Unmanned Aerial Vehicle T2 - Deutscher Luft- und Raumfahrtkongress - DLRK 2019. Darmstadt, Germany Y1 - 2019 SP - 1 EP - 10 ER -