TY - CHAP A1 - Schopp, Christoph A1 - Heuermann, Holger T1 - Electrodeless low pressure lamp with bi-static matching at 2.45 GHz T2 - 2013 European Microwave Conference (EuMC) , Nuremberg Y1 - 2013 SN - 978-1-4799-0264-4 SP - 881 EP - 884 PB - IEEE CY - Piscataway, NJ ER - TY - BOOK A1 - Bochmann, Sandra A1 - Ritz, Thomas T1 - Prototyping tools for mobile applications Y1 - 2013 SN - 978-3-943356-45-8 PB - Steinbeis-Ed. CY - Stuttgart ER - TY - CHAP A1 - Niemüller, Tim A1 - Ewert, Daniel A1 - Reuter, Sebastian A1 - Karras, Ulrich A1 - Ferrein, Alexander T1 - Towards benchmarking cyber-physical systems in factory automation scenarios T2 - KI 2013: advances in artificial intelligence : 36th Annual German Conference on AI, Koblenz, Germany, September 16-20, 2013 ; proceedings / Ingo J. Timm ... (ed.). (Lecture notes in computer science ; 8077) Y1 - 2013 SN - 978-3-642-40941-7 SP - 296 EP - 299 PB - Springer CY - Berlin [u.a.] ER - TY - CHAP A1 - Niemüller, Tim A1 - Lakemeyer, Gerhard A1 - Ferrein, Alexander ED - Boots, Byron T1 - Incremental task-level reasoning in a competitive factory automation scenario T2 - Designing intelligent robots : reintegrating AI II ; papers from the AAAI spring symposium ; [held March 25 - 27, 2013 in Palo Alto, California, USA, on the campus of Stanford University]. (Technical Report / Association for the Advancement of Artificial Intelligence ; 2013,4) Y1 - 2013 SN - 9781577356011 SP - 43 EP - 48 ER - TY - JOUR A1 - Niemüller, Tim A1 - Lakemeyer, Gerhard A1 - Ferrein, Alexander A1 - Reuter, S. A1 - Ewert, D. A1 - Jeschke, S. A1 - Pensky, D. A1 - Karras, Ulrich T1 - Proposal for advancements to the LLSF in 2014 and beyond Y1 - 2013 SP - Publ. online ER - TY - CHAP A1 - Bitz, Andreas A1 - Kobus, Thiele A1 - Scheenen, Tom W. J. A1 - Ladd, Mark E. T1 - RF Safety of the Combination of a 31P Tx/Rx Endorectal Coil & a 1H Tx/Rx Body Array for 31P MRSI of the Prostate at 7T (311.) T2 - 20th Annual ISMRM scientific meeting and exhibition 2012 : Melbourne, Australia, 5 - 11 May 2012 Y1 - 2013 SN - 978-1-62276-943-8 SN - 1545-4428 IS - Volume 1 SP - 311 PB - Curran CY - Red Hook, NY ER - TY - JOUR A1 - Orzada, Stephan A1 - Johst, Sören A1 - Maderwald, Stefan A1 - Bitz, Andreas A1 - Solbach, Klaus A1 - Ladd, Mark E. T1 - Mitigation of B1(+) inhomogeneity on single-channel transmit systems with TIAMO JF - Magnetic Resonance in Medicine Y1 - 2013 U6 - https://doi.org/10.1002/mrm.24453 SN - 1522-2594 VL - 70 IS - 1 SP - 290 EP - 294 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Umutlu, Lale A1 - Bitz, Andreas A1 - Maderwald, Stefan A1 - Orzada, Stephan A1 - Kinner, Sonja A1 - Kraff, Oliver A1 - Brote, Irina A1 - Ladd, Susanne C. A1 - Schroeder, Tobias A1 - Forsting, Michael T1 - Contrast-enhanced ultra-high-field liver MRI: a feasibility trial JF - European Journal of Radiology Y1 - 2013 U6 - https://doi.org/10.1016/j.ejrad.2011.07.004 SN - 0720-048X VL - 82 IS - 5 SP - 760 EP - 767 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Umutlu, Lale A1 - Kraff, Oliver A1 - Fischer, Anja A1 - Kinner, Sonja A1 - Maderwald, Stefan A1 - Nassenstein, Kai A1 - Nensa, Felix A1 - Grüneisen, Johannes A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Forsting, Michael A1 - Ladd, Mark E. A1 - Lauenstein, Thomas C. T1 - Seven-Tesla MRI of the female pelvis JF - European Radiology Y1 - 2013 U6 - https://doi.org/10.1007/s00330-013-2868-0 SN - 1432-1084 VL - 23 IS - 9 SP - 2364 EP - 2373 PB - Springer CY - Berlin ER - TY - JOUR A1 - Bitz, Andreas A1 - Felder, Jorg A1 - Wittig, Tilmann T1 - Designing MRI Coils with Aid of Simulation JF - Microwaves & RF Y1 - 2013 SN - 0745-2993 VL - 52 IS - 7 SP - 56 PB - Penton CY - Cleveland, Ohio ER - TY - JOUR A1 - Kraff, Oliver A1 - Wrede, Karsten H. A1 - Schoemberg, Tobias A1 - Dammann, Philipp A1 - Noureddine, Yacine A1 - Orzada, Stephan A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - MR safety assessment of potential RF heating from cranial fixation plates at 7 T JF - Medical Physics Y1 - 2013 U6 - https://doi.org/10.1118/1.4795347 SN - 2473-4209 VL - 40 IS - 4 SP - 042302-1 EP - 042302-10 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Umutlu, L. A1 - Maderwald, S. A1 - Kinner, S. A1 - Kraff, O. A1 - Bitz, Andreas A1 - Orzada, S. A1 - Johst, S. A1 - Wrede, K. A1 - Forsting, M. A1 - Ladd, M. E. A1 - Lauenstein, T. C. A1 - Quick, H. H. T1 - First-pass contrast-enhanced renal MRA at 7 Tesla: initial results JF - European Radiology Y1 - 2013 U6 - https://doi.org/10.1007/s00330-012-2666-0 SN - 1432-1084 VL - 23 IS - 4 SP - 1059 EP - 1066 PB - Springer CY - Berlin ER - TY - JOUR A1 - Rens, Gavin A1 - Ferrein, Alexander T1 - Belief-node condensation for online POMDP algorithms N2 - Slightly extended version of the paper accepted at the Robotics and Artificial Intelligence Workshop, a special track of IEEE AFRICON-2013, held in Mauritius, 9-12 September 2013 Y1 - 2013 SP - 1 EP - 7 PB - IEEE CY - New York ER - TY - CHAP A1 - Ferrein, Alexander A1 - Niemüller, Tim A1 - Schiffer, Stefan A1 - Lakemeyer, Gerhard ED - Boots, Byron T1 - Lessons learnt from developing the embodied AI platform CAESAR for domestic service robotics T2 - Designing intelligent robots : reintegrating AI II ; papers from the AAAI spring symposium ; [held March 25 - 27, 2013 in Palo Alto, California, USA, on the campus of Stanford University]. (Technical Report / Association for the Advancement of Artificial Intelligence ; 2013,4) Y1 - 2013 SN - 9781577356011 SP - 21 EP - 26 ER - TY - CHAP A1 - Leingartner, Max A1 - Maurer, Johannes A1 - Steinbauer, Gerald A1 - Ferrein, Alexander T1 - Evaluation of sensors and mapping approaches for disasters in tunnels T2 - IEEE International Symposium on Safety, Security, and Rescue Robotics : SSRR : 21-26 Oct. 2013, Linkoping, Sweden Y1 - 2013 SN - 978-1-4799-0879-0 SP - 1 EP - 7 ER - TY - CHAP A1 - Niemüller, Tim A1 - Ewert, Daniel A1 - Reuter, Sebastian A1 - Ferrein, Alexander A1 - Jeschke, Sabina A1 - Lakemeyer, Gerhard T1 - The Carologistics RoboCup Logistics Team 2013 T2 - RoboCup 2013 : Eindhoven Y1 - 2013 SP - 1 EP - 8 ER - TY - CHAP A1 - Heuermann, Holger A1 - Sadeghfam, Arash A1 - Finger, Torsten T1 - Alternative ignition system based on microwave plasma T2 - Advanced ignition systems for gasoline engines : [Vorträge der 1st International Conference Advanced Ignition Systems for Gasoline Engines - 1. Internationale Tagung Zündsysteme für Ottomotoren, 12.-13. November 2012, Berlin] Y1 - 2013 SN - 9783816931904 SP - 95 EP - 103 PB - Expert-Verl. CY - Renningen ER - TY - CHAP A1 - Priede, Gareth A1 - Ferrein, Alexander T1 - Towards passive walking for the fully-actuated biped robot Nao T2 - Emerging trends in computing, informatics, systems sciences, and engineering. (Lecture notes in electrical engineering : vol. 151) N2 - Many biped robots deploy a form of gait that follows the zero moment point (ZMP) approach, that is, the robot is in a stable position at any point in time. This requires the robot to be fully actuated. While very stable, the draw-backs of this approach are a fairly slow gait and high energy consumption. An alternative approach is the so-called passive-dynamic walking, where the gait makes use of the inertia and dynamic stability of the robot. In this paper we describe our ongoing work of combining the principles of passive-dynamic walking on the fully-actuated biped robot Nao, which is also deployed for robotic soccer applications. We present a simple controller that allows the robot to stably rock sidewards, showing a closed limit-cycle. We discuss first results of superimposing a forward motion on the sidewards motion. Based on this we expect to endow the Nao with a fast, robust, and stable passive-dynamic walk on the fully-actuated Nao in the future. Y1 - 2013 SN - 978-1-4614-3557-0 ; 978-1-4614-3558-7 U6 - https://doi.org/10.1007/978-1-4614-3558-7_18 SP - 225 EP - 236 PB - Springer CY - New York, NY ER - TY - GEN A1 - Waiczies, Helmar A1 - Kühne, André A1 - Winter, Lukas A1 - Frauenrath, Tobias A1 - Hoffmann, Werner A1 - Ittermann, Bernd A1 - Waiczies, Sonia A1 - Niendorf, Thoralf T1 - Towards theranostics of rheumatoid arthritis: 1H/19F imaging of non-steroidal anti-inflammatory drugs in hand and wrist at 7 Tesla T2 - 2013 ISMRM Annual Meeting Proceedings N2 - We have developed a double-tuned ¹H/¹⁹F birdcage resonator dedicated for hand and wrist imaging at 7 T to locally image non-steroidal anti-inflammatory drugs (NSAID) such as 2-{[3-(Trifluoromethyl) phenyl]amino}benzoic acid. The preliminary in vivo images acquired by the double-tuned ¹H/¹⁹F birdcage resonator demonstrate the feasibility for ¹H/¹⁹F hand- and wrist-imaging at 7 T. While the diagnostic quality of the coil needs to be assessed in patients with inflammatory rheumatoid disease, first ¹⁹F images of the NSAID are encouraging, and point towards the prospect of applying ¹⁹F-MRI to visualize and quantify the concentration of therapeutically-active compound at the sites of inflammation. Y1 - 2013 SN - 1545-4428 N1 - ISMRM 21st Annual Meeting & Exhibition, 20-26 April 2013, Salt Lake City, Utah, USA ER - TY - JOUR A1 - Gräßl, Andreas A1 - Renz, Wolfgang A1 - Hezel, Fabian A1 - Dieringer, Matthias A. A1 - Winter, Lukas A1 - Özerdem, Celal A1 - Rieger, Jan A1 - Kellmann, Peter A1 - Santoro, Davide A1 - Lindel, Tomasz D. A1 - Frauenrath, Tobias A1 - Pfeiffer, Harald A1 - Niendorf, Thoralf T1 - Modular 32-channel transceiver coil array for cardiac MRI at 7.0T JF - Magnetic Resonance in Medicine N2 - Purpose To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T. Methods The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study. Results Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly. Conclusion The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T. Y1 - 2013 U6 - https://doi.org/10.1002/mrm.24903 SN - 1522-2594 VL - 72 IS - 1 SP - 276 EP - 290 PB - Wiley-Liss CY - New York ER - TY - CHAP A1 - Nötzold, K. A1 - Uphues, A. A1 - Wegener, R. A1 - Fink, K. A1 - Bragard, Michael A1 - Griessel, R. A1 - Soter, S. T1 - Inverter based test setup for LVRT verification of a full-scale 2 MW wind power converter T2 - 15th European Conference on Power Electronics and Applications (EPE), 2013 : 2 - 6 Sept. 2013, Lille, France / [EPE Association; PELS, IEEE Power Electronics Society] Y1 - 2013 SN - 978-1-4799-0115-9 (Online-Ausg.) U6 - https://doi.org/10.1109/EPE.2013.6634752 SP - 1037 EP - 1042 PB - IEEE CY - Piscataway, NJ ER - TY - CHAP A1 - Niemüller, Tim A1 - Lakemeyer, Gerhard A1 - Ferrein, Alexander T1 - Aspects of integrating diverse software into robotic systems extended abstract T2 - ICRA 2013 - 8th Workshop on Software Development and Integration in Robotics (SDIR), Karlsruhe, Germany Y1 - 2013 SP - 1 EP - 2 ER - TY - CHAP A1 - Damm, Sebastian A1 - Rahier, Michael A1 - Ritz, Thomas A1 - Schäfer, Thomas ED - Davoli, Renzo T1 - Architecture for platform- and hardware-independent mesh networks : how to unify the channels T2 - ICSNC 2013 : The Eighth International Conference on Systems and Networks Communications ; October 27, 2013 to October 31, 2013, Venice Italy N2 - This paper will prove that mesh networks among different platforms and hardware channels can help to channel valuable information even if public telecommunication infrastructure is not available due to arbitrary reasons. Therefore, results of a simulation for mesh networks on mass events will be provided, followed by the developed architecture and an outlook on future research. The developed architecture is currently being implemented and field tested on mass events. Y1 - 2013 SN - 978-1-61208-305-6 N1 - IARIA Conference SP - 131 EP - 134 PB - Curran Associates CY - Red Hook, NY ER - TY - CHAP A1 - Wolf, Martin R. A1 - Wiese, Ute T1 - A comparative transformation model for process changes using serious games T2 - 2013 IEEE 2nd International Conference on Serious Games and Applications for Health (SeGAH): proceedings of a meeting held 2-3 May 2013, Algarve, Portugal Y1 - 2013 SN - 978-1-4673-6164-4 U6 - https://doi.org/10.1109/SeGAH.2013.6665307 SP - 64 EP - 70 PB - Institute of Electrical and Electronics Engineers (IEEE) CY - Piscataway, NJ ER - TY - JOUR A1 - Jens, Otto A1 - Kaldenhoff, E. A1 - Kirschner-Hermanns, R. A1 - Mühl, Thomas A1 - Klinge, Uwe T1 - Elongation of textile pelvic floor implants under load is related to complete loss of effective porosity, thereby favoring incorporation in scar plates JF - Journal of biomedical materials research. Part A N2 - Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome. Y1 - 2014 U6 - https://doi.org/10.1002/jbm.a.34767 SN - 1552-4965 VL - 102 IS - 4 SP - 1079 EP - 1084 PB - Wiley CY - New York ER - TY - BOOK A1 - Hüning, Felix T1 - The fundamentals of electrical engineering for mechatronics Y1 - 2014 SN - 978-3-11-034991-7 (Druckausg.) SN - 978-3-11-030840-2 (E-Book) PB - de Gruyter CY - Berlin ER - TY - CHAP A1 - Niemüller, Tim A1 - Ewert, Daniel A1 - Reuter, Sebastian A1 - Ferrein, Alexander A1 - Jeschke, Sabina A1 - Lakemeyer, Gerhard T1 - RoboCup logistics league sponsored by festo: A competitive factory automation testbed T2 - RoboCup 2013: Robot World Cup XVII : Eindhoven; Netherlands; 1 July 2013 through 1 July 2013. (Lecture notes in computer science ; 8371) N2 - A new trend in automation is to deploy so-called cyber-physical systems (CPS) which combine computation with physical processes. The novel RoboCup Logistics League Sponsored by Festo (LLSF) aims at such CPS logistic scenarios in an automation setting. A team of robots has to produce products from a number of semi-finished products which they have to machine during the game. Different production plans are possible and the robots need to recycle scrap byproducts. This way, the LLSF is a very interesting league offering a number of challenging research questions for planning, coordination, or communication in an application-driven scenario. In this paper, we outline the objectives of the LLSF and present steps for developing the league further towards a benchmark for logistics scenarios for CPS. As a major milestone we present the new automated referee system which helps in governing the game play as well as keeping track of the scored points in a very complex factory scenario. Y1 - 2014 SN - 978-3-662-44467-2 (Print) 978-3-662-44468-9 (Online) SP - 336 EP - 347 PB - Springer CY - Berlin ER - TY - JOUR A1 - Alhwarin, Faraj A1 - Ferrein, Alexander A1 - Scholl, Ingrid T1 - IR stereo kinect: improving depth images by combining structured light with IR stereo Y1 - 2014 SP - 1 EP - 9 ER - TY - JOUR A1 - Haag, S. A1 - Zontar, D. A1 - Schleupen, Josef A1 - Müller, T. A1 - Brecher, C. T1 - Chain of refined perception in self-optimizing assembly of micro-optical systems JF - Journal of sensors and sensor systems N2 - Today, the assembly of laser systems requires a large share of manual operations due to its complexity regarding the optimal alignment of optics. Although the feasibility of automated alignment of laser optics has been shown in research labs, the development effort for the automation of assembly does not meet economic requirements – especially for low-volume laser production. This paper presents a model-based and sensor-integrated assembly execution approach for flexible assembly cells consisting of a macro-positioner covering a large workspace and a compact micromanipulator with camera attached to the positioner. In order to make full use of available models from computer-aided design (CAD) and optical simulation, sensor systems at different levels of accuracy are used for matching perceived information with model data. This approach is named "chain of refined perception", and it allows for automated planning of complex assembly tasks along all major phases of assembly such as collision-free path planning, part feeding, and active and passive alignment. The focus of the paper is put on the in-process image-based metrology and information extraction used for identifying and calibrating local coordinate systems as well as the exploitation of that information for a part feeding process for micro-optics. Results will be presented regarding the processes of automated calibration of the robot camera as well as the local coordinate systems of part feeding area and robot base. Y1 - 2014 U6 - https://doi.org/10.5194/jsss-3-87-2014 SN - 2194-878X VL - 3 IS - 1 SP - 87 EP - 95 PB - Copernicus Publ. CY - Göttingen ER - TY - JOUR A1 - Altherr, Lena A1 - Ederer, Thorsten A1 - Lorenz, Ulf A1 - Pelz, Peter F. A1 - Pöttgen, Philipp ED - Lübbecke, Marco ED - Koster, Arie ED - Letmathe, Peter ED - Madlener, Reihard ED - Peis, Britta ED - Walther, Grit T1 - Experimental validation of an enhanced system synthesis approach JF - Operations Research Proceedings 2014 N2 - Planning the layout and operation of a technical system is a common task for an engineer. Typically, the workflow is divided into consecutive stages: First, the engineer designs the layout of the system, with the help of his experience or of heuristic methods. Secondly, he finds a control strategy which is often optimized by simulation. This usually results in a good operating of an unquestioned sys- tem topology. In contrast, we apply Operations Research (OR) methods to find a cost-optimal solution for both stages simultaneously via mixed integer program- ming (MILP). Technical Operations Research (TOR) allows one to find a provable global optimal solution within the model formulation. However, the modeling error due to the abstraction of physical reality remains unknown. We address this ubiq- uitous problem of OR methods by comparing our computational results with mea- surements in a test rig. For a practical test case we compute a topology and control strategy via MILP and verify that the objectives are met up to a deviation of 8.7%. Y1 - 2014 SN - 978-3-319-28695-2 U6 - https://doi.org/10.1007/978-3-319-28697-6_1 PB - Springer CY - Basel ER - TY - JOUR A1 - Vos, E. K. A1 - Lagemaat, M. W. A1 - Barentsz, J. O. A1 - Fütterer, J. J. A1 - Zamecnik, P. A1 - Roozen, H. A1 - Orzada, S. A1 - Bitz, Andreas A1 - Maas, M. C. A1 - Scheenen, T. W. J. T1 - Image quality and cancer visibility of T2-weighted Magnetic Resonance Imaging of the prostate at 7 Tesla JF - European Radiology N2 - Objectives To assess the image quality of T2-weighted (T2w) magnetic resonance imaging of the prostate and the visibility of prostate cancer at 7 Tesla (T). Materials & methods Seventeen prostate cancer patients underwent T2w imaging at 7T with only an external transmit/receive array coil. Three radiologists independently scored images for image quality, visibility of anatomical structures, and presence of artefacts. Krippendorff’s alpha and weighted kappa statistics were used to assess inter-observer agreement. Visibility of prostate cancer lesions was assessed by directly linking the T2w images to the confirmed location of prostate cancer on histopathology. Results T2w imaging at 7T was achievable with ‘satisfactory’ (3/5) to ‘good’ (4/5) quality. Visibility of anatomical structures was predominantly scored as ‘satisfactory’ (3/5) and ‘good’ (4/5). If artefacts were present, they were mostly motion artefacts and, to a lesser extent, aliasing artefacts and noise. Krippendorff’s analysis revealed an α = 0.44 between three readers for the overall image quality scores. Clinically significant cancer lesions in both peripheral zone and transition zone were visible at 7T. Conclusion T2w imaging with satisfactory to good quality can be routinely acquired, and cancer lesions were visible in patients with prostate cancer at 7T using only an external transmit/receive body array coil. Y1 - 2014 U6 - https://doi.org/10.1007/s00330-014-3234-6 SN - 1432-1084 VL - 24 IS - 8 SP - 1950 EP - 1958 PB - Springer CY - Cham ER - TY - JOUR A1 - Theysohn, Jens M. A1 - Kraff, Oliver A1 - Eilers, Kristina A1 - Andrade, Dorian A1 - Gerwig, Marcus A1 - Timmann, Dagmar A1 - Schmitt, Franz A1 - Ladd, Mark E. A1 - Ladd, Susanne C. A1 - Bitz, Andreas T1 - Vestibular effects of a 7 Tesla MRI examination compared to 1.5 T and 0 T in healthy volunteers JF - PLoS one N2 - Ultra-high-field MRI (7 Tesla (T) and above) elicits more temporary side-effects compared to 1.5 T and 3 T, e.g. dizziness or “postural instability” even after exiting the scanner. The current study aims to assess quantitatively vestibular performance before and after exposure to different MRI scenarios at 7 T, 1.5 T and 0 T. Sway path and body axis rotation (Unterberger's stepping test) were quantitatively recorded in a total of 46 volunteers before, 2 minutes after, and 15 minutes after different exposure scenarios: 7 T head MRI (n = 27), 7 T no RF (n = 22), 7 T only B₀ (n = 20), 7 T in & out B₀ (n = 20), 1.5 T no RF (n = 20), 0 T (n = 15). All exposure scenarios lasted 30 minutes except for brief one minute exposure in 7 T in & out B₀. Both measures were documented utilizing a 3D ultrasound system. During sway path evaluation, the experiment was repeated with eyes both open and closed. Sway paths for all long-lasting 7 T scenarios (normal, no RF, only B₀) with eyes closed were significantly prolonged 2 minutes after exiting the scanner, normalizing after 15 minutes. Brief exposure to 7 T B₀ or 30 minutes exposure to 1.5 T or 0 T did not show significant changes. End positions after Unterberger's stepping test were significantly changed counter-clockwise after all 7 T scenarios, including the brief in & out B₀ exposure. Shorter exposure resulted in a smaller alteration angle. In contrast to sway path, reversal of changes in body axis rotation was incomplete after 15 minutes. 1.5 T caused no rotational changes. The results show that exposure to the 7 Tesla static magnetic field causes only a temporary dysfunction or “over-compensation” of the vestibular system not measurable at 1.5 or 0 Tesla. Radiofrequency fields, gradient switching, and orthostatic dysregulation do not seem to play a role. Y1 - 2014 U6 - https://doi.org/10.1371/journal.pone.0092104 SN - 1932-6203 VL - 9 IS - 3 PB - PLOS CY - San Francisco ER - TY - JOUR A1 - Lagemaat, Miriam W. A1 - Vos, Eline K. A1 - Maas, Marnix C. A1 - Bitz, Andreas A1 - Orzada, Stephan A1 - Uden, Mark J. van A1 - Kobus, Thiele A1 - Heerschap, Arend A1 - Scheenen, Tom W. J. T1 - Phosphorus magnetic resonance spectroscopic imaging at 7 T in patients with prostate cancer JF - Investigative Radiology N2 - Objectives The aim of this study was to identify characteristics of phosphorus (³¹P) spectra of the human prostate and to investigate changes of individual phospholipid metabolites in prostate cancer through in vivo ³¹P magnetic resonance spectroscopic imaging (MRSI) at 7 T. Materials and Methods In this institutional review board–approved study, 15 patients with biopsy-proven prostate cancer underwent T₂-weighted magnetic resonance imaging and 3-dimensional ³¹P MRSI at 7 T. Voxels were selected at the tumor location, in normal-appearing peripheral zone tissue, normal-appearing transition zone tissue, and in the base of the prostate close to the seminal vesicles. Phosphorus metabolite ratios were determined and compared between tissue types. Results Signals of phosphoethanolamine (PE) and phosphocholine (PC) were present and well resolved in most ³¹P spectra in the prostate. Glycerophosphocholine signals were observable in 43% of the voxels in malignant tissue, but in only 10% of the voxels in normal-appearing tissue away from the seminal vesicles. In many spectra, independent of tissue type, 2 peaks resonated in the chemical shift range of inorganic phosphate, possibly representing 2 separate pH compartments. The PC/PE ratio in the seminal vesicles was highly elevated compared with the prostate in 5 patients. A considerable overlap of ³¹P metabolite ratios was found between prostate cancer and normal-appearing prostate tissue, preventing direct discrimination of these tissues. The only 2 patients with high Gleason scores tumors (≥4+5) presented with high PC and glycerophosphocholine levels in their cancer lesions. Conclusions Phosphorus MRSI at 7 T shows distinct features of phospholipid metabolites in the prostate gland and its surrounding structures. In this exploratory study, no differences in ³¹P metabolite ratios were observed between prostate cancer and normal-appearing prostate tissue possibly because of the partial volume effects of small tumor foci in large MRSI voxels. Y1 - 2014 U6 - https://doi.org/10.1097/RLI.0000000000000012 SN - 1536-0210 VL - 49 IS - 5 SP - 363 EP - 372 PB - Lippincott Williams & Wilkins CY - Philadelphia, Pa. ER - TY - JOUR A1 - Maas, Marnix C. A1 - Vos, Eline K. A1 - Lagemaat, Miriam W. A1 - Bitz, Andreas A1 - Orzada, Stephan A1 - Kobus, Thiele A1 - Kraff, Oliver A1 - Maderwald, Stefan A1 - Ladd, Mark E. A1 - Scheenen, Tom W. J. T1 - Feasibility of T₂-weighted turbo spin echo imaging of the human prostate at 7 tesla JF - Magnetic Resonance in Medicine N2 - Purpose To demonstrate that high quality T₂-weighted (T2w) turbo spin-echo (TSE) imaging of the complete prostate can be achieved routinely and within safety limits at 7 T, using an external transceive body array coil only. Methods Nine healthy volunteers and 12 prostate cancer patients were scanned on a 7 T whole-body system. Preparation consisted of B₀ and radiofrequency shimming and localized flip angle calibration. T₁ and T₂ relaxation times were measured and used to define the T2w-TSE protocol. T2w imaging was performed using a TSE sequence (pulse repetition time/echo time 3000–3640/71 ms) with prolonged excitation and refocusing pulses to reduce specific absorption rate. Results High quality T2w TSE imaging was performed in less than 2 min in all subjects. Tumors of patients with gold-standard tumor localization (MR-guided biopsy or prostatectomy) were well visualized on 7 T imaging (n = 3). The number of consecutive slices achievable within a 10-g averaged specific absorption rate limit of 10 W/kg was ≥28 in all subjects, sufficient for full prostate coverage with 3-mm slices in at least one direction. Conclusion High quality T2w TSE prostate imaging can be performed routinely and within specific absorption rate limits at 7 T with an external transceive body array. Y1 - 2014 U6 - https://doi.org/10.1002/mrm.24818 SN - 1522-2594 VL - 71 IS - 5 SP - 1711 EP - 1719 PB - Wiley-VCH CY - Weinheim ER - TY - CHAP A1 - Alhwarin, Faraj A1 - Ferrein, Alexander A1 - Scholl, Ingrid T1 - IR stereo kinect: improving depth images by combining structured light with IR stereo T2 - PRICAI 2014: Trends in artificial intelligence : 13th Pacific Rim International Conference on Artificial Intelligence : Gold Coast, QLD, Australia, December 1-5, 2014 : proceedings. (Lecture notes in computer science ; vol. 8862) N2 - RGB-D sensors such as the Microsoft Kinect or the Asus Xtion are inexpensive 3D sensors. A depth image is computed by calculating the distortion of a known infrared light (IR) pattern which is projected into the scene. While these sensors are great devices they have some limitations. The distance they can measure is limited and they suffer from reflection problems on transparent, shiny, or very matte and absorbing objects. If more than one RGB-D camera is used the IR patterns interfere with each other. This results in a massive loss of depth information. In this paper, we present a simple and powerful method to overcome these problems. We propose a stereo RGB-D camera system which uses the pros of RGB-D cameras and combine them with the pros of stereo camera systems. The idea is to utilize the IR images of each two sensors as a stereo pair to generate a depth map. The IR patterns emitted by IR projectors are exploited here to enhance the dense stereo matching even if the observed objects or surfaces are texture-less or transparent. The resulting disparity map is then fused with the depth map offered by the RGB-D sensor to fill the regions and the holes that appear because of interference, or due to transparent or reflective objects. Our results show that the density of depth information is increased especially for transparent, shiny or matte objects. Y1 - 2014 SN - 978-3-319-13559-5 (Print) ; 978-3-319-13560-1 (E-Book) U6 - https://doi.org/10.1007/978-3-319-13560-1_33 SP - 409 EP - 421 PB - Springer CY - München ER - TY - CHAP A1 - Heuermann, Holger A1 - Finger, Torsten T1 - 2.45 GHz Plasma Powered Spark Plug by Thermal and EM-Optimization Y1 - 2014 N1 - Ansys High Frequency Simulation Conference - AHFSC 2014, Munich; 02/2014 ER - TY - CHAP A1 - Schopp, Christoph A1 - Heuermann, Holger A1 - Holtrup, S. T1 - Investigation on efficacy optimization of RF-driven automotive D-lamps T2 - 44th European Microwave Conference (EuMC),2014, Rome Y1 - 2014 U6 - https://doi.org/10.1109/EuMC.2014.6986645 SP - 1154 EP - 1157 ER - TY - CHAP A1 - Neumann, Tobias A1 - Ferrein, Alexander A1 - Kallweit, Stephan A1 - Scholl, Ingrid T1 - Towards a mobile mapping robot for underground mines T2 - 7th Conference of Robotics and Mechatronics : RobMech 2014 : 27th and 28th Nov. 2014, Cape Town Y1 - 2014 SP - 1 EP - 6 ER - TY - CHAP A1 - Neugebauer, Georg A1 - Brutschy, Lucas A1 - Meyer, Ulrike A1 - Wetzel, Susanne ED - Garcia-Alfaro, Joaquin ED - Lioudakis, Georgios ED - Cuppens-Boulahia, Nora ED - Foley, Simon ED - Fitzgerald, William M. T1 - Privacy-preserving multi-party reconciliation secure in the malicious model T2 - DPM 2013, SETOP 2013: Data Privacy Management and Autonomous Spontaneous Security N2 - The problem of fair and privacy-preserving ordered set reconciliation arises in a variety of applications like auctions, e-voting, and appointment reconciliation. While several multi-party protocols have been proposed that solve this problem in the semi-honest model, there are no multi-party protocols that are secure in the malicious model so far. In this paper, we close this gap. Our newly proposed protocols are shown to be secure in the malicious model based on a variety of novel non-interactive zero-knowledge-proofs. We describe the implementation of our protocols and evaluate their performance in comparison to protocols solving the problem in the semi-honest case. KW - Privacy-enhancing technologies KW - Secure multi-party computation KW - Cryptographic protocols KW - Zero-knowledge proofs KW - Malicious model Y1 - 2014 SN - 978-3-642-54567-2 (Print) SN - 978-3-642-54568-9 (Online) U6 - https://doi.org/10.1007/978-3-642-54568-9_12 N1 - 8th International Workshop, DPM 2013, and 6th International Workshop, SETOP 2013, Egham, UK, September 12-13, 2013. Part of the Lecture Notes in Computer Science book series (LNSC,volume 8247) SP - 178 EP - 193 PB - Springer CY - Berlin ER - TY - CHAP A1 - Lenz, Laura L. A1 - Wolf, Martin R. ED - Kritz, Willy Christian T1 - Economic evaluation of serious games with the comparative assessment framework COSEGA T2 - The shift from teaching to learning : individual, collective and organizational learning through gaming simulation ; proceedings of the 45th conference of the International Simulation and Gaming Association, Dornbirn 2014 Y1 - 2014 SN - 978-3-7639-5422-3 SP - 374 EP - 386 PB - Bertelsmann CY - [Bielefeld] ER - TY - CHAP A1 - Ritz, Thomas A1 - Izquierdo Tello, César A1 - Damm, Sebastian T1 - Connecting a pedelec to the cloud as basis for gamification in multi modal mobility planning T2 - MobileCloud 2014 : 2nd IEEE International Conference on Mobile Cloud Computing, Services, and Engineering Oxford, United Kingdom 7-10 April 2014 Y1 - 2014 SN - 978-1-4799-2504-9 U6 - https://doi.org/10.1109/MobileCloud.2014.25 SP - 101 EP - 108 PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Holtrup, S. A1 - Sadeghfam, Arash A1 - Heuermann, Holger A1 - Awakowicz, P. T1 - Characterization and optimization technique for microwave-driven high-intensity discharge lamps using hot S-parameters JF - IEEE transactions on microwave theories and techniques N2 - High-intensity discharge lamps can be driven by radio-frequency signals in the ISM frequency band at 2.45 GHz, using a matching network to transform the impedance of the plasma to the source impedance. To achieve an optimal operating condition, a good characterization of the lamp in terms of radio frequency equivalent circuits under operating conditions is necessary, enabling the design of an efficient matching network. This paper presents the characterization technique for such lamps and presents the design of the required matching network. For the characterization, a high-intensity discharge lamp was driven by a monofrequent large signal at 2.45 GHz, whereas a frequency sweep over 300 MHz was performed across this signal to measure so-called small-signal hot S-parameters using a vector network analyzer. These parameters are then used as an equivalent load in a circuit simulator to design an appropriate matching network. Using the measured data as a black-box model in the simulation results in a quick and efficient method to simulate and design efficient matching networks in spite of the complex plasma behavior. Furthermore, photometric analysis of high-intensity discharge lamps are carried out, comparing microwave operation to conventional operation. Y1 - 2014 U6 - https://doi.org/10.1109/TMTT.2014.2342652 SN - 0018-9480 VL - 62 IS - 10 SP - 2471 EP - 2480 PB - IEEE CY - New York ER - TY - JOUR A1 - Beck, Daniel A1 - Buchleitner, Martin A1 - Ferrein, Alexander A1 - Niemüller, Tim A1 - Steinbauer, Gerald T1 - Mostly Harmless & AllemaniACs - mixed innovations Y1 - 2014 SP - 1 EP - 8 ER - TY - CHAP A1 - Fuchs, Britta A1 - Ritz, Thomas T1 - Usability for Blended Shopping - Solving Major Flaws by Applying Usability Engineering and Proven Integration Technologies T2 - Proceedings of the 11th International Conference on e-Business, ICE-B 2014, Vienna, Austria Y1 - 2014 SN - 978-989-758-043-7 U6 - https://doi.org/10.5220/0005113502160223 SP - 216 EP - 223 ER - TY - CHAP A1 - Heuermann, Holger A1 - Finger, Torsten ED - Günther, Michael T1 - Microwave Spark Plug for Very High-Pressure Conditions T2 - Ignition systems for gasoline engines Y1 - 2014 SP - 269 EP - 282 PB - DCM Druck CY - Meckenheim ER - TY - CHAP A1 - Gebhardt, Andreas A1 - Ritz, Thomas A1 - Siekmann, Kirsten A1 - Wallenborn, Ramona ED - Demmer, Axel T1 - Additive manufacturing businesses in the process chain of individualized mass products T2 - DDMC 2014 : Proceedings of the Fraunhofer Direct Digital Manufacturing Conference Y1 - 2014 SN - 978-3-8396-9128-1 (E-Book) PB - Fraunhofer CY - Stuttgart ER - TY - PAT A1 - Nötzold, K. A1 - Bragard, Michael A1 - Fink, K. A1 - Griessel, R. A1 - Wegener, R. T1 - Cascaded H-bridge converter with transformer based cell power balancing in each voltage level : [Patentschrift] Y1 - 2014 N1 - Titel des US-Patents: Bypassed cascaded cell converter : [patent of invention]. - Außerdem veröffentlicht als CN103997231 (A) PB - Europäisches Patentamt / United States Patent and Trademark Office [u.a.] CY - Den Haag / Alexandria, VA ER - TY - CHAP A1 - Hüning, Felix T1 - Power semiconductors : key components for HEV/EV T2 - FISITA 2014 World Automotive Congress : 2 - 6 June, Maastricht, the Netherlands International Federation of Automotive Engineering Societies Y1 - 2014 N1 - Datenformat: PDF PB - KIVI CY - [s.l.] ER - TY - CHAP A1 - Bonney, Gregor A1 - Höfken, Hans-Wilhelm A1 - Paffen, Benedikt A1 - Schuba, Marko T1 - ICS/SCADA Security - Analysis of a Beckhoff CX5020 PLC T2 - 1st International Conference on Information Systems Security and Privacy : ICISSP 2015 Y1 - 2015 SP - 1 EP - 6 ER - TY - CHAP A1 - Lindenlauf, Simon A1 - Höfken, Hans-Wilhelm A1 - Schuba, Marko T1 - Cold Boot Attacks on DDR2 and DDR3 SDRAM T2 - 10th International Conference on Availability, Reliability and Security (ARES) 2015 Y1 - 2015 U6 - https://doi.org/10.1109/ARES.2015.28 SP - 287 EP - 292 ER -